Hexaplexer - Amphenol Antenna Solutions

Hexaplexer
HPX-19x-NF-CC
Hexaplexer | 728-894/925-960/1805-1990/2110-2170/2300-2400/2496-2690 MHz | No DC Bypass | Single or Double Units | Outdoor
•
•
•
•
•
Combines six bands 728-894/925-960/1805-1990/2110-2170/2300-2400/2496-2690 MHz into a single output
Usable at BTS or antenna end
Built in lightning protection on all ports
Suitable for outdoor applications
Pole or wall mounting
Ordering Options
No DC/AISG bypass
Single Unit
Double Unit
HPX-190-NF-CC
HPX-191-NF-CC
Electrical Characteristics
Port 1
Frequency Band
728-894 MHz
Insertion Loss
≤ 0.5 dB
Pass Band Ripple
≤ 0.3 dB
Isolation
≥ 45 dB
VSWR
≤ 1.3
Power Rating
200 W (peak max)
Input Power Rating (ports 1-6)
1200 W (peak max)
Intermodulation, 2x43 dBm
Impedance
-150 dBc
50Ω
Port 2
Frequency Band
925-960 MHz
Insertion Loss
≤ 0.5 dB
Pass Band Ripple
≤ 0.3 dB
Isolation
≥ 45 dB
VSWR
≤ 1.3
Power Rating
200 W (peak max)
Input Power Rating (ports 1-6)
1200 W (peak max)
Intermodulation, 2x43 dBm
Impedance
-150 dBc
50Ω
Port 3
Frequency Band
1805-1990 MHz
Insertion Loss
≤ 0.5 dB
Pass Band Ripple
≤ 0.3 dB
Isolation
≥ 45 dB
VSWR
≤ 1.3
Power Rating
200 W (peak max)
Input Power Rating (ports 1-6)
1200 W (peak max)
Intermodulation, 2x43 dBm TX Carrier
Impedance
-150 dBc
50Ω
Quoted performance parameters are provided to offer typical, peak or range values only and may vary as a result of normal testing, manufacturing and operational conditions. Extreme
operational conditions and/or stress on structural supports is beyond our control. Such conditions may result in damage to this product. Improvements to products may be made without notice.
REV012618CC
www.amphenol-antennas.com
1 of 3
Hexaplexer
HPX-19x-NF-CC
Hexaplexer | 728-894/925-960/1805-1990/2110-2170/2300-2400/2496-2690 MHz | No DC Bypass | Single or Double Units | Outdoor
Port 4
Frequency Band
2110-2170 MHz
Insertion Loss
≤ 0.5 dB
Pass Band Ripple
≤ 0.3 dB
Isolation
≥ 45 dB
VSWR
≤ 1.3
Power Rating
200 W (peak max)
Input Power Rating (ports 1-6)
1200 W (peak max)
Intermodulation, 2x43 dBm TX Carrier
-150 dBc
Impedance
50Ω
Port 5
Frequency Band
2300-2400 MHz
Insertion Loss
≤ 0.5 dB
Pass Band Ripple
≤ 0.3 dB
Isolation
≥ 45 dB
VSWR
≤ 1.3
Power Rating
200 W (peak max)
Input Power Rating (ports 1-6)
1200 W (peak max)
Intermodulation, 2x43 dBm TX Carrier
-150 dBc
Impedance
50Ω
Port 6
Frequency Band
2496-2690 MHz
Insertion Loss
≤ 0.5 dB
Pass Band Ripple
≤ 0.3 dB
Isolation
≥ 45 dB
VSWR
≤ 1.3
Power Rating
200 W (peak max)
Input Power Rating (ports 1-6)
1200 W (peak max)
Intermodulation, 2x43 dBm TX Carrier
-150 dBc
Impedance
50Ω
Quoted performance parameters are provided to offer typical, peak or range values only and may vary as a result of normal testing, manufacturing and operational conditions. Extreme
operational conditions and/or stress on structural supports is beyond our control. Such conditions may result in damage to this product. Improvements to products may be made without notice.
REV012618CC
www.amphenol-antennas.com
2 of 3
Hexaplexer
HPX-19x-NF-CC
Hexaplexer | 728-894/925-960/1805-1990/2110-2170/2300-2400/2496-2690 MHz | No DC Bypass | Single or Double Units | Outdoor
Environmental
Operating Temperature Range
-20° to +50° C
-4° to 122° F
Storage Temperature Range
-40° to +75° C
-40° to 167° F
Operating Humidity
95% (none condensing)
Ingress Protection
IP67
Application
Outdoor
Salt & Fog
protection required
Fungus
protection required
MTBF
150,000 hours
Mechanical Characteristics
Connectors
Dimensions (H x W x D)
Weight
N Female
209 x 328 x 54 mm
5.6 kg
8.2 x 12.9 x 2.1 in
12.3 lbs
Quoted performance parameters are provided to offer typical, peak or range values only and may vary as a result of normal testing, manufacturing and operational conditions. Extreme
operational conditions and/or stress on structural supports is beyond our control. Such conditions may result in damage to this product. Improvements to products may be made without notice.
REV012618CC
www.amphenol-antennas.com
3 of 3
Download PDF