Shield
Power
Commander Tower
Designed to ensure clean power and reliable
operation of all kinds of IT devices in the network
system. The Commander protects your equipment
against power failures, power sags, power surges,
under voltage and over voltage that can harm your
equipment or result in corrupted data. The pure sine
features
wave output on battery backup is best for server and
motor applications.
• Highestsurgerating-1558 Joules/ 40,000 Amps ofsurge
protection
The Commander provides a cost effective and high
• Works with gates, camera surveillance, computers,
level of protection for sensitive electronic devices. It
also offers options for graceful shutdown of valuable
IT equipment.
electronic equipment.
It comes with the highest surge rating of any standard
UPS
with
1558
telephone systems, servers, and other sensitive
Joules
and
40,000
Amp
• IntelligentRealTimeBatterybackupdisplay
surge
protection. The narrow output voltage variance of 5%
ensures that sensitive equipment is subjected to only
• Smart 5% AVR with 2 step buck and boost
• Pure sine wave line interactive
small voltage inconsistencies. The LCD display gives
the user the ability to see voltages in/out, frequency
• Intelligent double stage charger control which
in/out as well as temperature, load and battery
voltage. In addition, these UPSs have Real Time
Battery Management which tells how many minutes
translates to a faster recharge rate
• Generator compatible
backup the user has when the power goes off.
applications include:
• network devices
• servers
• small networks
• PLCs
• Automatic Gates and Doors
THEAUSTRALIAN UPS COMPANY
www.powershield.com.au
COMMANDER TOWER
PSC2000
PSC1000
Model
1000V A/700W
Capacity
Topology
2000VA /1400W
Line Interactive, Pure Sine Wave
INPUT
180 - 300VAC
Input Voltage range
47Hz - 65Hz, 50/60Hz
Frequency
Auto-sensing
OUTPUT
240 +/- 5% (2 step buck and boost)
O utput Voltage
Nominal Voltage +/- 5% or (Optional +/-8% AVR for wide input up to 35%)
Output Voltage regulation
200Vac or 220Vac or 230V ac or 240Vac
Output Voltage selectable
Frequency
47 - 55Hz for 50Hz nominal, 56Hz - 65Hz for 60Hz nominal or (batter y mode 50Hz +/- 1%)
Wave Form - AC Mode
Pure sine Wave
Wave Form - Batt. Mode
Pure sine Wave
Transfer t ime
<3ms
Load crest Factor
3:1
Australian sockets
2
10Amp
3
IEC outlets
BATTERY
Sealed maintenance free lead acid batteries (12V*7.2AH)
Battery t ype
Number of batteries
Charger
4
2
Smart CPU controls over current, over voltage, thermal protection and battery condition
Less than 3 hours to 90% (smart two mode pulse charging)
Recharge time
Half load 14 minutes, full load 5 minutes
Typical backup
PROTECTION
1581 Joules /40,000 Amps
Input surge Protection
AC Fuse
Short circuit
Telephone / Modem / Lan
RJ45, Full time telephone, modem or LAN protection. C-tic, A-tick
COMMUNICATIONS & MANAGEMENT
USB & RS232 as Standard, Intelligent slot for SNMP or AS400 dry contact
Interface
Software
LCD display
Audible alar m
PowerShield UPsilon 2000 compatible with Windows, Linux, Novell & Unix
Sophisticated LCD- Input Voltage, Output Voltage, Frequency, Load, Battery Status, Smart Remaining Backup Time
Alarm On Battery, Overload, Short Circuit, Over Temperature, Faulty Battery, Abnormal Operation
PHYSICAL
Dimensions (D x W x H)
(380 x 200 x 180)mm
Weight (Net/Gross)
(510 x 200 x 180)mm
(15kg/16kg)
(26kg/26kg)
OPERATING ENVIRONMENT
Temperature
Humidity
Noise Level
0 - 40 oC
0 - 95% (RH Non-condesing)
Less than 40dB
COMPLIANCE
Safety
EMC
RoHS
EN 50091-1-1
Class B, EN 50091-2, FCC part 15, IEC1000-2-2, C-tick (Full time EMI-RFI filtering)
Directive 2011/65/EU
* Specifications are subject mto change without prior notice.