Model 8910, 8910W, 8920W Thermostat

8900 Series IAQ Controls
Model
8920W
Shown
Programmable
8910
8910W
8920W
Universal 3H/3C or 4H/2C HP
Universal 3H/3C or 4H/2C HP
Universal 3H/3C or 4H/2C HP
Event-Based™ Air Cleaning
Event-Based™ Air Cleaning
Event-Based™ Air Cleaning
Humidity and Ventilation
Humidity and Ventilation
Humidity and Ventilation
2 Part — 3-Wire design
2 Part — 3-Wire design
2 Part — 3-Wire design
Wi-Fi touch screen
Full Color Wi-Fi touch screen
Aprilaire Advantage: Total IAQ Control
i-Fi with IAQ Control:
W
Models 8910W, 8920W
Event-Based™ Air Cleaning
resh air ventilation:
F
timed or ASHRAE
Color touch screen: Model 8920W
3-wire design
Maintenance reminders
ree custom imprintable
F
cover: Models 8910, 8910W
ealer info displayed on
D
screen: Model 8920W
BUMPER to BUMPER
Heat Blast™ schedule override
5-YEAR
WARRANTY
Equipment
Control Module
8910 Also
Available
Aprilaire 8900 Series IAQ Control
The Aprilaire 8900 Series IAQ Control Thermostats consist of two
components, the User Interface and the Equipment Control Module. The
User Interface, located in the living space, integrates all indoor air quality
functions – heating/cooling, humidification/dehumidification, air cleaning
and ventilation in one attractive, easy-to-use, touch screen control. The
User Interface offers homeowners the ability to easily set all of their IAQ
and HVAC products from one location in the living space. The primary
screen indicates how to easily activate and control set points. In addition,
Intuitive User Interface
8920W
the display provides the homeowner with confirmation that the equipment
is operating at the desired control settings.
3-Wire Connection
Optional Return Air Temperature
Sensor (RAT) provides protection with
heating and cooling back-up control if
connection is lost.
Optional Leaving Air Temperature
Sensor (LAT) provides the supply air
temperature during the installer test.
Included — Wired Outdoor
Temperature Sensor 8052 (ODT)
Optional Wireless Outdoor
Temperature Sensor 8056 (ODT)
8 LEDs indicate HVAC
Equipment and IAQ
Accessory Status
IAQ Control Features
Temperature Control
++ Universal Programmable Thermostat 3H/3C Conventional or 4H/2C Heat Pump
++ Selectable, 7 day, 5/2, 5/1/1 or non
programmable 2 or 4 events/day
Model 8910
++ 7 day or non-programmable 4 events/day
Models 8910W, 8920W
++ Dual fuel operation
++ Adjustable differential for all stages
++ Stage rate control uses equipment run
time to control HVAC equipment staging
++ Progressive Recovery feature ensures
that the setpoint is reached by the
scheduled time
++ Heat Blast™ allows one touch control of
heating to raise room temperature 3°F to 5°F
++ High and low balance points (must use ODT)
++ Screen lock-out to prevent unauthorized
adjustments
Humidity Control
Humidifier
++ Displays indoor RH on User Interface
++ Notifies when humidifier is active
++ Automatic humidity setpoint adjustment (must use ODT) or Manual Control
++ Water Panel® replacement reminder
Dehumidifier
++ Displays indoor RH on User Interface
++ Notifies when dehumidifier is active
++ Operates whole-home dehumidifier or air conditioner to dehumidify
++ Dehumidifier service reminder
++ Energizes HVAC blower when dehumidifying
Fresh Air Ventilation
++ Provides fresh air with a motorized damper or an ERV/HRV
++ Notifies when ventilation is active
++ Control limits based upon outdoor temperature and RH
++ Can be set up to use ASHRAE 62.2 guidelines or timed ventilation
Air Cleaning
++ Event Based™ Air Cleaning - 4 selectable air cleaning events
– Constant Cleaning (24/7)
– Automatic (30 Min/Hr)
– Event Clean (3 Hr Cycle)
– Allergy (24 Hr Cycle)
++ Notifies when air cleaning is active
++ Media replacement reminder
++ Controls EAC with dedicated 24 VAC dry contact
8900 Series IAQ Control Thermostats
Easy to Install & Maintain
Engineered for Excellence
Easy & Convenient to use
++ 24 VAC powered with battery backup for
user interface Model 8910 only
++ Circulate fan mode
++ Large 10.3 sq. in. touch screen Model 8910
++ Dual fuel operation (auto lockout of
compressor w/call for back-up heat)
++ Programmable fan
++ Large 20.4 sq. in. touch screen Model 8920W
++ Progressive recovery
++ Large font size
++ Programmable (or non-programmable)
++ Built-in equipment protection
++ Remote indoor sensor option with
8051/8053 sensors
++ Equipment stage indication
++ Fully back lit w/ constant low intensity
light option
++ Temperature offset ± 4°
++ High and low balance point control (requires
8052 sensor included)
++ 3H/3C conventional and 4H/2C heat pump
++ Multiple hold options maximizes comfort
and energy savings
- Vacation hold
- Customizable timed hold
- Permanent hold
++ Configurable manual heat/cool or auto
changeover modes
++ Permanent memory — programming, time
and date isn’t lost during a power outage
++ Configurable for heating only or cooling
only operation
++ Heat Blast™ allows one touch control of heating
to raise room temperature 3°F to 5°F
++ Large, easy-to-wire terminal block
++ 5-year warranty
++ Adjustable differential for 1st, 2nd, 3rd
and 4th stages
++ Exclusive message center (provides
feedback and real language instructions)
++ Displays outdoor temperature
(w/included 8052 sensor)
++ Real language programming/set up —
no manual needed, no codes to memorize
++ Full or limited screen lockout
++ “Copy” function for quick and easy programming
++ Real time clock automatically adjusts
for daylight savings time
++ Service reminders
- Humidifier, Air Cleaner, Dehumidifier,
HVAC Model 8910
- Humidifier, Air Cleaner, Dehumidifier,
Ventilation, HVAC Models 8910W, 8920W
Dimensions
Thermal Specifications
Electrical Specifications
User interface
6" x 4.85" x 1.25" Models 8910, 8910W
7.1" x 4.4" x 1" Model 8920W
Control range
40° to 99°F (4° to 32°C)
24 VAC powered (18-30 VAC)
Equipment control module
8.6" x 9.6" x 1.9"
Accessories
1 amp maximum load per terminal
Display range
32° to 99°F (0° to 40°C)
2.5 amp total maximum load (all terminals)
Accuracy
± 1°F (± .5°C)
Single stage/heat pump/multi-stage
Standard systems gas, oil, electric
Storage temperature
-30° to 140°F (-34.4° to 60°C)
Terminal Designations 8051 Flush Mount Indoor Temperature
Sensor (optional)
Operating humidity
5% to 90% relative humidity non-condensing
8053 Surface Mount Indoor Temperature
Sensor (optional)
Operating ambient temperature
of user interface
32° to 120°F (0° to 48.9°C)
Equipment control module: 1, 2, 3, RAT,
LAT, ODT, C, R, RC, RH, W, W2, W3/B, Y,
Y2, Y3/O, G, L, CEQ, HUM, DHNO, DHNC,
DHCOM, VENT, EAC
8052 Outdoor Temperature Sensor
(included)
8056 Wireless Outdoor Temperature
Sensor (optional)
Return Air Temperature Sensor (RAT)
optional sensor provides protection with
heating and cooling back-up control if
connection is lost
Operating ambient temperature of ECM
32° to 158°F (0° to 70°C)
Shipping temperature range
-30° to 140°F (-34.4° to 60°C)
Leaving Air Temperature Sensor (LAT)
optional sensor provides the supply air
temperature during the installer test
AprilairePartners.com
Form No.5227• 273227 6.17
©2017 Aprilaire – Division of Research Products Corporation
P.O. Box 1467
Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
User interface: 1, 2, 3, T1, T2