PK11S6 11KW / 11KVA KUBOTA DIESEL GENERATOR
KUBOTA D1105-BG Diesel Engine
STAMFORD NEWAGE BCI164A Alternator
STANDARD SPECIFICATIONS
Fully Packaged Kubota Generator Includes:













Powered by Kubota diesel engine
Stamford Newage alternator (Leroy Somer available)
Deepsea 5220 Microprocessor control panel, Digital
3 pole MCB, Main Line Circuit Breaker, output rated
Incorporated fuel tank (50 to 10,000Gal available)
12V Varta battery rack and cables
12V Engine Charge alternator
12 Lead Single bearing alternator IP23, insulation class H
Radiator for wiring T°of 50°C [122°F] with mechanical fan
Mechanically welded chassis with anti-vibration isolators
Dry type air filter, Fuel filter and Oil filter elements installed
Soundproof and Weatherproof enclosures available
Each unit prototype and individually load bank tested
Diesel Genset Main Technical Data
60Hz, 1800RPM, 1PHASE, 0.8PF 240V
Sound
kVA
kW
Tank
Model
Level
(L)
ESP PRP ESP
PRP
dB(A)
PK11S6S
24
57.8
11
10
11
10
KUBOTA Engine, 1800RPM
Model
Bore/ stroke
mm
Cyl.
Asp.
Gov.
D1105-BG
78/78.4
3L
NA
M
(1) Sound level measurement at 7-meter distance from generator
(2) Ambient reference conditions: 1,000 m bar, 27℃, 30% relative humidity. Rating according to ISO 3046 and 8528.
(3) Available in the following voltages: 240/120V.
(4) ESP: Standby Power Standby duty, operation under variable load, without over load.
PRP: Prime Power-Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours.
Reliable Performance
Voltage Regulation
Voltage regulation maintained within ±0.5% as follows:
● Between 0.8 and 1.0 lagging and unity, From no load to full load
● At speed droop variation up to 4.5%
Frequency Adjustable Ratio
● Load from 0-100%, within 1.0% (electric regulator), within 4.5% (mechanical regulator) Frequency Undulation
● Load from 0-100%, Frequency undulation within 0.25%
Conforms To
● No load wire volts max undulation ratio within 1.8%
ISO3046, ISO8528, BS4999, BS5514,
Effect factor of telecom
BS5000PT99, AS1359, IEC34
● TIF better than 50, THF to BS4999 Part 40 better than 2%
UTE5100, VDE0530
Electromagnetism
ISO9001:2000
● In compliance with BS800 and VDE levels G and N
www.dieselgeneratorsmiami.com
GENERAL POWER LIMITED, INC
8145 N.W. 33rd Street / Miami, Florida 33172
(P) 305 471 9566 (P) 1 888 POWER58 (F) 305 471 9568
www.genpowerusa.com
generators@genpowerusa.com
Kubota Engine
Stamford Alternator
PK11S6S KUBOTA DIESEL GENERATOR
ENGINE SPECIFICATION
Engine Technical Data
KUBOTA DIESEL ENGINE
Kubota, a leading supplier of reliable diesel engines,
introduces the convenient One Side Maintenance type
E-TVCS engines.
E-TVCS (Three Vortex Combustion System)
Kubota’s highly efficient combustion system, located in a
specially designed piston with a valve recess and a
fanshaped concave, produces an ideal air/fuel mixture by
creating 3 vortexes in the combustion chamber. This results in
a better cross flow of air and exhaust gas, lower intake
temperature and improved combustion efficiency.
High in output, low in fuel consumption
E-TVCS superb combustion system not only improved the
power output, but it has also reduced the engine’s fuel
consumption.
Lower noise level
Noise levels are held to an unprecedented low level thanks to
the E-TVCS, an offset piston with the standard built-in steel
strut, and the increase rigidity of the crank and gear cases.
Engine Model
D1105-BG
Engine manufacturer /Brand
No. of cylinders/Arrangement
Cycle
Induction system
Compression ratio
Displacement
L
Kubota
3/In line
4 stroke
Natural
22:1
1.1
Bore x Stroke
78X78.4
Gross engine power
mm
KW(hp)
11.5 (15.4)
Starting system
12V
Battery voltage/Charging amps
12VDC/30A
Governing type/Class
Mechanical/ISO8528G1
Filtering systems
Replaceable elements
Cooling system
Liquid cooled
Fuel consumption 100%
PRP
2.2L/h (0.5Gal/h)
Fuel autonomy at 100%
PRP
11 hours
Warranty
Excellent service access further improves maintenance and
support is provided by a worldwide network of 1000
distributors and dealers.
AC ALTERNATOR SPECIFICATION
Alternator Technical Data
STAMFORD NEWAGE GENERATOR
STAMFORD NEWAGE, owned by Cummins Generator
Technologies, has a long history of producing high-quality
reliable products for the power generation market. Their
portfolio of high quality generator ends is recognized as an
industry standard.
Alternator Technical Data
Stamford AC alternator













Brushless, self exciting
Class ‘H’ insulation
Standard degree of protection is IP23
Self regulating
With fan cooling
Resist humid grease
AC excitation, rotating rectification tube
Stator grease insulation covered
Rotator and excitation high polymer
Resist the corruption of oil and acid
Rotator balance is in accordance with BS5625 standard 12.5
High-quality lubrication sealed long-time bearing
Rotator silicon steel close tight
Generator Model
BCI164C
Exciter
Brushless
Cooling Fan
Cast alloy aluminum
Bearing
Single, double shielded
Windings
100% copper
Connection Type
12lead, Reconnectable
Insulation Type
Class H
Pitch
2/3
Amortisseur Winding
Full
A.V.R. Model
SX460
Voltage Regulation NL - FL
± 1.0%
Underspeed Protection
Standard
Overexcitation Protection
IP23
Standards
NEMA, IEC, IEEE, CSA, BS
Phase Sequence
A(U), B(V), C(W)
TIF (1960 Weightings)
<50
Excitation System
Self-excited, PMG optional
www.dieselgeneratorsmiami.com
GENERAL POWER LIMITED, INC
8145 N.W. 33rd Street / Miami, Florida 33172
(P) 305 471 9566 (P) 1 888 POWER58 (F) 305 471 9568
www.genpowerusa.com
generators@genpowerusa.com
Kubota Engine
Stamford Alternator
PK11S6S KUBOTA DIESEL GENERATOR
CONTROL SYSTEMS
DEEPSEA 5220 CONTROL (DIGITAL)
The DSE5220 is an Automatic Mains Failure Control Module
designed to monitor a mains (utility) supply and automatically
start and stop diesel and gas generating sets that include non
electronic engines. Upon detection of a mains (utility) failure
the module automatically starts the generating set. Once the
mains power has been restored the module instructs the
generating set to stop. The module also provides excellent
engine monitoring and protection features:
1.
2.
3.
4.
5.
Automatic engine start/stop
Engine monitoring and protection
Breaker control
Generator protection
Automatic Mains Failure (ATS / AMF)
Optional applications:
6. RS232 or RS485 communications capabilities for
linking to a PC, sending SMS messages and interfacing
with new and existing building management systems.
Standard functions
Engine Control
Generator Monitoring
Generator Protection
Engine Monitoring
Clear Text Display
Shutdown
Loss of Speed Signal
Alternator Under / Over Voltage
Alternator Under/ Over Frequency
Mains Under / Over Voltage
Mains Under/ Over Frequency
Under / Over Speed
Low Oil Pressure
High Engine Temperature
Phase Sequence Electrical (Option)
Earth Fault (Option)
Warning
Alternator Under / Over Voltage
Alternator Under/ Over Frequency
Mains Under / Over Voltage
Mains Under/ Over Frequency
Under / Over Speed
Low Oil Pressure Pre-Alarm
High Engine Temperature Pre-Alarm
High/Low Battery Voltage
Over-current
Periodic maintenance
PLC-702 CONTROL SYSTEM (ANALOG)
The PLC702 is an Automatic Mains Failure Control Module
specialized for Residential, Portable and Telecoms applications.
It’s simplicity and low cost make it an ideal solution for a wide
range of applications
Standard Functions
► Manual Engine Control Module
► Low Oil Pressure
► High Engine Temperature
► Auxiliary Shutdown
► Overspeed Protection
► Protection hold-off timer
► Charge Failure warning
PLC 702-HC Module
PLC
Model
Meters702-HC
for Hz, Speed,
Temp., Voltage, current
Fuse Protection
Circuit Breaker
Emergency Stop Button
Ground
Heavy Load Connector
www.dieselgeneratorsmiami.com
Wires
GENERAL POWER LIMITED, INC
8145 N.W. 33rd Street / Miami, Florida 33122
(P) 305 471 9566 (P) 1 888 POWER58 (F) 305 471 9568
www.genpowerusa.com
generators@genpowerusa.com
Kubota Engine
Stamford Alternator
PK11S6S KUBOTA DIESEL GENERATOR
GENERATOR OPTIONS AND ACCESSORIES
ENCLOSURES
WEATHER PROOF / SOUND ATTENUATED
• Protect your stationary and mobile generator against bad weather, theft and unauthorized use
• Sound attenuating and fire retardant foam or fiberglass panels provide excellent noise reduction
• Critical class silencer and flexible exhaust connector installed inside the canopy
• High gauge electro zinc coated steel with a polyester powder coat for maximum corrosion resistance
• Large lockable doors allow convenient access for all maintenance and service items
• Single point lifting hook fixed to the generator steel frame
• Forklift pockets in the base frame for convenient transport
• Recessed emergency stop button accessible outside the enclosure
• Cooling air discharge with a vertical air outlet grille. Redirects cooling air up and above enclosures to
reduce noise ambient
AUTOMATIC TRANSFER SWITCHES (ATS/AMF)
30 - 3000 AMP, ASCO SERIES165 & SERIES300
• With a Series 300 transfer switch, you get a product backed by ASCO Power Technologies, the
industry leader responsible for virtually every major technological advance in the industry
• True double-throw operation: The single solenoid design is inherently interlocked & prevents
contacts from stopping between sources or from being in contact with both sources at the
same time
• Easy-to-read flush-mounted control and display panel provides LED indicators for switch position and
source availability. It also includes test and time-delay bypass switches as standard features
• Standard engine exerciser for weekly automatic testing of diesel generator with or without load
• UL 1008 listed for Transfer Equipment and CSA C22.2 listed for automatic transfer switches
• NFPA 110 for Emergency & Standby Power & the National Electrical (NEC) Articles 700,
701 and 702
• Adjustable time-delay feature prevents switch from being activated due to momentary power outages
EXTENDED RUNTIME/CAPACITY FUEL TANKS
25 - 5500 GAL, UL142 LISTED MODELS AVAILABLE
• Available in single-wall and double-wall design
• UL listed. Secondary containment tank meeting UL 142 tank requirements (optional)
• NFPA compliant. Designed to comply with the installation standards of NFPA 30 and NFPA 37
(optional)
• Emergency pressure relief vents. Meets UL requirements; ensures adequate venting of inner and outer
tank under extreme pressure and/or emergency conditions
• Electrical stub-up area with removable end channel
• Normal vent • Inner tank emergency vent sized to UL 142 specifications
• Direct reading mechanical fuel gauge • Fuel in basin switch
• Satin black paint finish
DIMENSIONS AND WEIGHT
OPEN VERSION
DIMENSIONS mm (in)
NET WEIGHT kg (lbs)
ENCLOSED VERSION
DIMENSIONS mm (in)
WEIGHT kg (lbs)
TYPE A
1680 x 975 x 1335 (66 x 38 x 53)
680 (1496)
TYPE A
TYPE B
*Type A frame features Control panel and Breaker installed on top of the alternator
*Type B frame features Control panel and Breaker installed in front of the alternator
www.dieselgeneratorsmiami.com
GENERAL POWER LIMITED, INC
8145 N.W. 33rd Street / Miami, Florida 33122
(P) 305 471 9566 (P) 1 888 POWER58 (F) 305 471 9568
www.genpowerusa.com
generators@genpowerusa.com
Download PDF

advertising