Mixed bed DI resin cartridge specifications
Application
Capacity
Design flow rate
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Micron rating
Demineralization
See chart below
See chart below
100°F (38°C)
40°F (5°C)
125 PSI (8.6 bar)
20 PSI (1.4 bar)
Not rated
Mixed bed DI resin for demineralization. (Ideal cartridge to install post RO to lower TDS.)
Part Number
FPMBDIR-975
FPMBDIR-20
FPMBDIR-BB-975
FPMBDIR-BB-20
O.D.
Length
2-1/2"
2-1/2"
4-1/2"
4-1/2"
9-3/4"
20"
9-3/4"
20"
Media
Purolite®
Purolite®
Purolite®
Purolite®
(w/color
(w/color
(w/color
(w/color
change
change
change
change
indicator)
indicator)
indicator)
indicator)
Capacity
(Grains)
Flow
Rate
No.
Case
300
700
900
1,900
1.0
1.0
2.0
3.0
24
12
8
4
Cation resin cartridge specifications
Application
Capacity
Design flow rate
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
To reduce water hardness
See chart below
See chart below
100°F (38°C)
40°F (5°C)
125 PSI (8.6 bar)
20 PSI (1.4 bar)
Cation resin cartridges for water softening. (Ideal for pre RO to reduce water hardness.)
Part Number
FPCATR-975
FPCATR-20
FPCATR-BB-975
FPCATR-BB-20
O.D.
Length
2-1/2"
2-1/2"
4-1/2"
4-1/2"
9-3/4"
20"
9-3/4"
20"
Media
100%
100%
100%
100%
Dow®
Dow®
Dow®
Dow®
Cation
Cation
Cation
Cation
resin
resin
resin
resin
Capacity
(Grains)
Flow
Rate
No.
Case
800
1,900
2,700
5,400
1.0
1.0
2.0
3.0
24
12
8
4
Capacity
(Grains)
Flow
Rate
No.
Case
4,000
8,000
9,000
16,000
0.5
1.0
2.0
3.0
24
12
8
4
Nitrate selective resin for Nitrate reduction.
Part Number
O.D.
Length
FPNSR-975
2-1/2"
2-1/2"
4-1/2"
4-1/2"
9-3/4"
20"
9-3/4"
20"
FPNSR-20
FPNSR-BB-975
FPNSR-BB-20
Media
Tulsion®
Tulsion®
Tulsion®
Tulsion®
Nitrate
Nitrate
Nitrate
Nitrate
selective
selective
selective
selective
Calcite + Coconut Shell GAC to neutralize acidic water,
reduce leaching of metal plumbing components and for use post RO to raise TDS.
Part Number
FPCR-975
FPCR-20
FPCR-BB-975
FPCR-BB-20
O.D.
Length
2-1/2"
2-1/2"
4-1/2"
4-1/2"
9-3/4"
20"
9-3/4"
20"
Media
Calcium
Calcium
Calcium
Calcium
Carbonate
Carbonate
Carbonate
Carbonate
+
+
+
+
GAC
GAC
GAC
GAC
Capacity
(Grains)
Flow
Rate
No.
Case
2,500
5,000
10,000
20,000
1.0
2.0
2.5
4.0
24
12
8
4
Warning: Do not use cartridges listed in this section with water that is microbiologically unsafe or unknown quality without proper
disinfection before or after the cartridge.
45
Filter cartridges
Return
HOME
GAC + Phosphate cartridge specifications
Application
Capacity
Design flow rate
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Carbon treatment + scale reduction
See chart below
See chart below
100°F (38°C)
40°F (5°C)
125 PSI (8.6 bar)
20 PSI (1.4 bar)
GAC + Phosphate (For carbon treatment plus scale reduction.)
Part Number
FPGACP-975
FPGACP-20
FPGACP-BB-975
FPGACP-BB-20
O.D.
Length
Media
(Grains)
Capacity
Rate
Flow
Case
No.
2-1/2"
2-1/2"
4-1/2"
4-1/2"
9-3/4"
20"
9-3/4"
20"
GAC + 8 oz. Phosphate
GAC + 16 oz. Phosphate
GAC + 18 oz. Phosphate
GAC + 36 oz. Phosphate
2,000
4,250
5,000
10,000
1.0
1.0
2.0
3.0
24
24
6
4
KDF85 + Coconut Shell GAC to reduce iron & hydrogen sulfide in ground water (point-of-entry)
Part Number
FPKDF85-975
FPKDF85-BB-975
FPKDF85-BB-20
O.D.
Length
Media
Capacity
(Grains)
Flow
Rate
No.
Case
2-1/2"
4-1/2"
4-1/2"
9-3/4"
9-3/4"
20"
KDF85 + GAC
KDF85 + GAC
KDF85 + GAC
2,500
10,000
20,000
1.0
2.0
4.0
12
8
4
KDF® 85 for ground water
KDF 85 process medium is an effective ferrous iron and hydrogen sulfide H2S) removal agents that may be used
alone or to to protect existing water filtration / purification technologies in point-of-entry treatment of ground water
supplies. This unique and patented medium consists of copper-zinc granules that use redox (exchange of
electrons) to effectively reduce / remove iron. hydrogen sulfide, and microorganisms in potable water, without the
use of chemicals. KDF85 is ideal for whole house water treatment using ground water.
KDF55 + Coconut Shell GAC for enhanced chlorine reduction in municipal water (point-of-entry)-of-entry)
Part Number
GAC10N/KDF
GAC-BB10K/900
GAC-BB20K/1800
O.D.
Length
Media
Capacity
(Grains)
Flow
Rate
No.
Case
2-1/2"
4-1/2"
4-1/2"
9-3/4"
9-3/4"
20"
KDF55 + GAC (.75 lbs. KDF)
KDF55 + GAC (2 lbs. KDF)
KDF55 + GAC (4 lbs. KDF)
2,500
10,000
20,000
1.0
2.0
4.0
24
8
4
KDF® 55 for municipal water
KDF 55 process medium is an effective chlorine removal agents that may be used in point-of-entry municipal water
supplies. This unique, innovative, enviromentally responsibile and patented medium consists of high
purity copper-zinc granules that use redox (exchange of electrons) to effectively reduce / remove chlorine and control microorganisms in potable water, without the use of chemicals. KDF55 is ideal for whole house water treatment
and in commerical buildings to reduce chlorine in municipal water with concentrations up to 5 ppm.
Warning: Do not use cartridges listed in this section with water that is microbiologically unsafe or unknown quality without
proper disinfection before or after the cartridge.
46
Return
HOME
Media type
Contaminant reduction
Capacity
Design flow rate
Initial pressure drop
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Micron rating
Granular Ferric Oxide
Arsenic V and III
1,000 gals. (2-3/4" OD); 3,000 gals. (4-1/2" OD)
0.5 GPM (both sizes)
< 8 psi at 0.5 GPM
100°F (38°C)
Recommended water quality:
pH, 6.5 - 8.5; Iron,<0.5 ppm
40°F (5°C)
Manganese<0.005 ppm.
125 PSI (8.6 bar)
20 PSI (1.4 bar)
25 nominal
Arsenic reduction cartridges.
Part Number
FPAR-975
FPAR-BB-975
O.D.
Length
Media
Capacity
(Grains)
Flow
Rate
No.
Case
2-1/2"
4-1/2"
9-3/4"
9-3/4"
Arsenic reduction
Arsenic reduction
1,000
3,000
0.75
1.5
24
8
Activated Alumina cartridge specifications
Reduction for
Capacity (<100 ppm hardness)
Design flow rate
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Micron rating
Fluoride
5,500 ppm (2-3/4" x 9-3/4")
0.25 GPM (9-3/4"); 0.5 GPM (20")
100°F (38°C)
40°F (5°C)
125 PSI (8.6 bar)
20 PSI (1.4 bar)
20 nominal
Activated Alumina for fluoride reduction.
Part Number
CAUDF10ALUM
CAUDS20ALUM
O.D.
Length
Capacity (PPM*)
Flow Rate
No. Case
2-1/2"
2-1/2"
9-3/4"
20"
5,500
11,000
0.25
0.5
12
6
*Hardness, up to 100 ppm. (Over 100 ppm, reduce capacity by 50% and above 200 ppm,
reduce capacity by 75%.)
Iron reduction cartridge specifications
Reduction for
Capacity
Design flow rate
Maximum temperature
Minimum temperature
Maximum pressure
Minimum pressure
Ferrous iron (dissolved), up to 3 ppm
25,000 gals (3 ppm); 40,000 gals. (2 ppm); 80,000 gals. (1 ppm)
4 - 6 GPM
Recommended water quality:
100°F (38°C)
pH, >7.0 Silica, <100 ppm;
Manganese, <1 ppm; Iron,<3 ppm;
40°F (5°C)
Iron Bacteria, none; Hydrogen
125 PSI (8.6 bar)
Sulfide, none.
20 PSI (1.4 bar)
Iron reduction cartridge for whole house to remove dissolved iron, metallic taste & stains
from plumbing fixtures.
Part Number
FPIR-BB-20
O.D.
Length
4-1/2"
20"
Description
Radial flow iron reduction cartridge
Flow Rate
(GPM)
No.
Case
4-6
6
Note: Flow rates are for sufficient contact time and are indicated in GPM, per cartridge. Users should base actual flow
rates on water quality, throughput requirements and performance criteria.
Warning: Do not use cartridges listed in this section with water that is microbiologically unsafe or unknown quality without
proper disinfection before or after the cartridge.
47
Filter cartridges
Arsenic reduction cartridge specifications
Filter cartridges
Return
HOME
In-Line Filters
In-line filters for reverse osmosis systems, ice makers and other water treatment needs.
In-line filters
For pre & post RO and ice maker filtration.
R
• AICRO® (our best selling in-line filter)
• AICRO-JGK* (With J. Guest fittings.)
* Coconut shell activated carbon. Rated for flow rates to
0.75. GPM and 1,500 gallons capacity
CERTIFIED
ANSI / NSF
STANDARD 42
(AICRO)
GAC
Part Number
O.D.
Length
Media
Type
Fitting Size
Fitting Type
No. / Case
CL10STT33
2”
2”
10”
10”
GAC
GAC
With mesh pre-filter
Acid washed bituminous
1/4”
1/4”
FNPT
FNPT
25
25
Type
Fitting Size
Fitting Type
No. / Case
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
3/8”
1/4”
FNPT
Quick ct
JG Elbow
FNPT
FNPT
J. Guest
J. Guest
J. Guest
FNPT
FNPT
FNPT
J. Guest
25
25
25
25
25
25
25
25
25
25
25
25
GS10PLUSB
Coconut shell GAC
Part Number
O.D.
Length
Media
AICRO
AICRO-JGK
K2533SS
CL6ROT33
CL10ROT33
K2333JJ
K2533JJ
K2633JJ
GS6ROB
GS10ROB
GS10ROC
GS10ROG
2”
2”
2”
2”
2”
2”
2”
2.5”
2”
2”
2”
2”
10”
10”
10”
6”
10”
6”
10”
12”
6”
10”
10”
10”
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
Acid
Acid
Acid
Acid
Acid
Coconut shell
Coconut shell
Coconut shell
wash coconut shell
wash coconut shell
wash coconut shell
wash coconut shell
wash coconut shell
Coconut shell
Coconut shell
Coconut shell
Coconut shell
GAC with Phosphate for scale reduction
Part Number
O.D.
Length
Media
Type
Fitting Size
Fitting Type
No. / Case
SCL6
SCL10
K2386JJ
K2586JJ
K2586SS
K5686JJ
Q5386
Q5486
Q5586
Q5686
GS6ALSB
GS10ALSB
2”
2”
2”
2”
2”
2.5”
2.5”
2.5”
2.5”
2.5”
2”
2”
6”
10”
6”
10”
10”
12”
6”
8”
10”
12”
6”
10”
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
GAC
AW GAC
AW GAC
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
Phosphate
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
1/4”
FNPT
FNPT
J. Guest
J. Guest
J. Guest
J. Guest
FNPT
FNPT
FNPT
FNPT
FNPT
FNPT
50
25
25
25
25
25
25
25
25
25
25
25
GAC + KDF
Part Number
O.D.
Length
AICRO/KDF050
AICRO/KDF075
GS6EXTRA.25B
GS6EXTRA.5B
GS210EXTRA1
2”
2”
2”
2”
2.5”
10”
10”
6”
10”
11”
Media
CS
CS
CS
CS
CS
GAC
GAC
GAC
GAC
GAC
Type
Fitting Size
Fitting Type
No. / Case
0.5 Lb. KDF55
0.75 Lb. KDF55
0.25 Lb. KDF55
0.5 Lb. KDF55
1.0 Lb. KDF55
1/4”
1/4”
1/4”
1/4”
1/4”
FNPT
FNPT
FNPT
FNPT
FNPT
25
25
25
25
20
Warning: Do not use filters listed in this section with water that is microbiologically unsafe or unknown quality without proper disinfection
before or after the filter.
48
Return
HOME
In-line filters with GAC and Calcite to raise TDS
Part Number
GS10CAL/ROB
O.D.
Length
Media
Type
Fitting Size
Fitting Type
No. / Case
2"
10"
GAC
With Calcite
1/4"
FNPT
25
Fitting Size
Fitting Type
No. / Case
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
FNPT
FNPT
FNPT
J. Guest
J. Guest
J. Guest
FNPT
FNPT
FNPT
FNPT
FNPT
FNPT
25
50
25
25
25
25
25
25
25
12
25
25
In-line filters for sediment
Part Number
O.D.
AIPRO
2"
CL6PF5
2"
CL10PF5
2"
K2305JJ
2"
K2505JJ
2"
K5605JJ
2"
CB+10-1B
2"
CB+10-5B
2"
CB+10-30B
2"
GS210LSB
2-1/2"
GS6SED/5B
2”
GS10SED/5B
2”
Length
10"
6"
10"
6"
10"
12"
10"
10"
10"
11"
6”
10”
Media
Micron
PP SPUN
5
PP SPUN
5
PP SPUN
5
PP SPUN
5
PP SPUN
5
PP SPUN
5
Carbon block
1
Carbon block
5
Carbon block
30
Carbon block 1 (lead, cyst reduction)
PP SPUN
5
PP SPUN
5
In-line filters with permanent heads
Ideal for beverage and food service applications with
E-Z cartridge replacement.
Heads
Permanent heads with and
without valve.
Heads
Part Number
Description
QHEAD
QHEAD-V
QBKT
Head without valve
Complete head with valve
Bracket for Q head
Fitting Size
Fitting Type
No. / Case
1/4"
1/4"
--
FNPT
FNPT
--
25
25
1
Replacable elements for permanent heads listed above.
Part Number
Q5520
Q5515
Q5333
Q5433
Q5533
Q5633
O.D.
Length
Media
Micron
Fitting Size
Fitting Type
No. / Case
2-1/2"
2-1/2"
2.5”
2.5”
2.5”
2.5”
10"
10"
6”
8”
10”
12”
Carbon block
Carbon block
Acid washed
Acid washed
Acid washed
Acid washed
1
1 (lead reduction)
5
5
5
5
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
FNPT
FNPT
FNPT
FNPT
FNPT
FNPT
25
25
25
25
25
25
Warning: Do not use filters listed in this section with water that is microbiologically unsafe or unknown quality without proper
disinfection before orafter the filter.
49
Filter cartridges
In-Line Filters
Download PDF
Similar pages