PCRSG0708C
RKS25G
RKS35G
RKS50G
RKS60G
RKS71H
RKS25G
1
RKS35G
RKS50G
RKS60G
RKS71H
2
FTKS25/35D
RKS25/35G
FTKS25DVM / RKS25GVMG
2.5 (1.2-3.2) kW
8,500 (4,050-10,900) Btu/h
FTKS35DVM / RKS35GVMG
3.5 (1.4-4.0) kW
11,900 (4,750-13,650) Btu/h
FTKS50/60G
RKS50/60G
FTKS50GVMG / RKS50GVMG
5.0 (1.7-6.0) kW
17,100 (5,800-20,500) Btu/h
FTKS60GVMG / RKS60GVMG
6.0 (2.3-6.7) kW
20,500 (7,800-22,900) Btu/h
*1
*1 Available with FTKS50/60G only.
3
FTKS71HVMG / RKS71HVMG
7.1 (2.3-8.5) kW
24,200 (7,800-29,000) Btu/h
FTKS71H
RKS71H
4
Compliance to Mandatory Energy Label
The 5 models listed below have received Singapore’s
National Environment Agency (NEA) energy labels for
household electrical appliances.
FTKS25D/RKS25G
FTKS35D/RKS35G
3.57
3.38
COP
FTKS50G/RKS50G FTKS60G/RKS60G FTKS71H/RKS71H
COP
3.57
3.37
3.38
What is COP?
An air conditioner’s COP (Coefficient of Performance)
indicates how efficiently the unit uses energy. A higher
COP means greater energy efficiency. It also means
lower electricity consumption, so you save money.
Capacity (W)
COP = Power consumption (W)
RKS25G
RKS35G
RKS50G
RKS60G
RKS71H
Inverter Advantages Compared to Non-Inverter
Inverters are devices that are able to vary their operating capacity by adjusting frequency. Inverter air
conditioners can vary their cooling capacity by adjusting the power supply frequency of their compressors.
In contrast, non-inverter air conditioners have a fixed cooling capacity and can only control the indoor
temperature by starting or stopping their compressors.
Powerful
Inverter air conditioners operate at
maximum capacity as soon as they
start up. As a result, the set
temperature can be reached more
quickly.
Variable Capacity Operation
Compressor
Inverter Power Control
Power
source
Raise frequency
High-speed rotation
High
capacity
Lower frequency
Low-speed rotation
Low
capacity
Non-inverter type air conditioner
Energy Saving
After the indoor temperature
approaches the set temperature,
Inverter Control adjusts to low
capacity operation to maintain this
temperature. This makes inverter
models more energy-saving than
non-inverter models, which must
repeatedly start or stop their
compressors to maintain the room
temperature.
Comfortable
Inverter air conditioners finely adjust
capacity according to changes in the
air-conditioning load and the difference
between the indoor temperature and
set temperature is small. These give
higher comfort levels than with noninverter air conditioners.
Power
source
Compressor
Constant speed
rotation
Fixed capacity
Inverter air conditioners are able to vary their operating capacity. Non-inverter air conditioners can
only operate at a fixed capacity.
Comfortable Temperature Control
Temp.
Compressor off
Not cool
Set
temp.
Compressor off
Cools a room
in less time
Too cool
Small temp.
difference
Time
During cooling operation
Non-inverter type
Inverter type
Starts
This diagram is a representation for illustrative purpose only.
5
Energy-Saving Technological Features
Swing Compressor
Swing compressor
Thanks to its smooth rotation, the
swing compressor decreases
friction and vibration. It also
prevents the leakage of
refrigerant gas during
compression. These advantages
provide quiet and efficient
operation.
Swing bush
Refrigerant gas
Integral piston of
blade and roller
The swing compressor can
reduce operational vibration and
sound because its piston moves
smoothly inside the compressor.
Reluctance DC motor
Reluctance DC Motor for Compressor
Neodymium magnets are used
in the pink-coloured area.
Efficiency of Reluctance DC motor *4
Motor efficiency (%)
Daikin DC Inverter models are equipped with
the Reluctance DC motor for compressor. The
Reluctance DC motor uses 2 different types of
torque, neodymium magnet*1 and reluctance
torque*2. This motor saves energy by generating
more power with a smaller electric current than
AC or conventional DC motors. It is more
efficient at the low frequencies most commonly
used by air conditioners,*3 improving efficiency
by approximately 20%.
Reluctance DC motor
90
80
Conventional
DC motor
More than 20%
70
AC motor
60
50
0
30
60
90
120
Rotational speed (rps)
Small load
Low capacity
*1. A neodymium magnet is approximately 10 times stronger than a standard ferrite
magnet.
*2. The torque created by the change in power between the iron and magnet parts.
*3. The frequency range used by air conditioners during periods of stable operation.
This is the range in which air conditioners operate for the longest periods.
*4. Data are based on studies conducted
under controlled conditions at a Daikin
laboratory using Daikin products.
PAM Control
DC Motor for Fan
Efficiency of DC motor for fan *5
100
Efficiency (%)
The DC motor allows fine rotation
control, which reduces energy
consumption. The motor also
provides improvements in
operational efficiency of up to 40%,
compared to an AC motor. These
improvements are particularly
noticeable in the low-speed range.
Large load
High capacity
(comparison with a conventional AC motor)
80
DC motor
Approx.
60
20%
increase
40
Approx.
AC motor
40%
20 increase
0
200
300
400
500
600
700
800
PAM (Pulse Amplitude Modulation)
control reduces energy loss by
controlling how often the converter
switches on and off.
900 1000
Motor speed (rpm)
*5. Data are based on studies conducted
under controlled conditions at a Daikin
laboratory using Daikin products.
What Is DC Inverter?
Daikin calls an inverter model that is equipped with a DC motor DC Inverter. A DC motor offers higher efficiency
than an AC motor. A DC motor uses the power of magnets to attract and repel to generate rotation. A DC motor
that is equipped with high-power neodymium magnets, which enable even greater efficiency, is called a Reluctance
DC motor.
6
Intelligent Eye
Intelligent Eye prevents energy wastage by using its
infrared sensor to detect human movement in a room.
When there is no movement, Intelligent Eye increases the
temperature by 2 C to give energy savings.
This reduces energy wastage if, for example, you
forget to turn off the air conditioner. The function can be
conveniently activated from the remote controller.
Once Intelligent Eye is set, it continues to work to save energy. You do not
need to push the SENSOR button each time you wish to use this function.
When you are in the room, the air
conditioner maintains the set
temperature.
If Intelligent Eye detects no human
movement for 20 minutes, it
automatically adjusts the set
temperature by 2 C.
Top view
7m
110˚
Intelligent Eye
The Intelligent Eye
indicator lights when sensor
movement is detected.
Side view
7m
When you enter the room,
Intelligent Eye automatically
returns the temperature to the
set level.
Econo Mode button
Intelligent Eye button
Econo Mode
FTKS25/35D
Running current and
power consumption
This function limits both the maximum running current
and maximum power consumption to 70%* of those
during normal operation. It is particularly effective if the
cooling load is high, for example, at start-up or during
large gatherings and periods of direct sunshine. At the
same time, it maintains maximum capacity at 80%* of
normal, giving improved operating efficiency, although it
may take slightly longer to reach the set temperature.
Econo Mode is also useful for preventing circuit
breakers from being overloaded during temporary
peaks in the running current. The function is easily
activated from the remote controller by pushing the
ECONO button. Econo Mode is available for
FTKS25/35D and 71H.
100%
Normal
operation
70%
Maximum during
normal operation
Maximum during
Econo Mode
Econo
Mode
From start-up until set
temperature is reached
Time
• This diagram is a representation for illustrative purposes only.
• Maximum capacity decreases during Econo Mode, requiring
more time to reach the set temperature.
*Econo Mode limits FTKS71H’s maximum power consumption to 50%
during normal operation and also maintains maximum capacity at 60%.
7
Indoor Unit Quiet Operation
This series gives you the choice of 5-step, Quiet or
Automatic settings for the fan speed. The Quiet setting
selects Indoor Unit Quiet Operation. This function
decreases the operation sound level by 3 dB (A) below
the Low setting.
This wide range of settings allows you to precisely
control the fan speed according to your requirements.
For example, Indoor Unit Quiet Operation provides you
with a good night’s sleep. The sound level for FTKS25D
is 22 dB (A).
FTKS25D
Fan speeds
Sound levels
High (H)
37 dB (A)
Low (L)
25 dB (A)
Quiet (SL)
22 dB (A)
Auto
SL
L
M
H
3 dB (A)
Fan
speed
Low
High
Each decrease in airflow volume
reduces the sound level.
Sound
level
Indoor Unit Quiet Operation icon
Selects fan speed and
Indoor Unit Quiet Operation
Outdoor Unit Quiet Operation
Outdoor Unit Quiet Operation
22 dB (A) Is So Quiet You Can Even Hear Whispers
Outdoor Unit Quiet Operation is available for all models
from 2.5 to 7.1 kW class. This function decreases the
operation sound level by 3 dB (A) below the rated
operation. It provides a low sound level of 43 dB (A) for
RKS25G.
Indoor unit
Capacity may decrease when Outdoor Unit Quiet Operation is selected.
20
RKS25G
Operations
Sound levels
Rated (H)
46 dB (A)
Quiet (L)
43 dB (A)
22
Rustling of leaves
30
Outdoor unit
40
50
(dB (A))
Library
Pendulum of a wall clock
3 dB (A)
43
Normal office
Based on “Examples of Sound Levels”, Ministry of the Environment, Japan,
November 12, 2002
8
Titanium Apatite Photocatalytic
Air-Purifying Filter
Titanium apatite is a new photocatalytic
material with advanced adsorption power. While
the filter’s micron-level fibres trap dust, this photocatalyst
effectively adsorbs and decomposes bacteria.
The photocatalyst is activated simply by exposure to
light. The filter delivers consistent performance for
approximately 3 years if periodic maintenance is
performed.
Air filter
Catches dust
Titanium Apatite
Photocatalytic
Air-Purifying Filter
This filter is not a medical device.
Benefits such as the adsorption
and decomposition of bacteria are
only effective for substances that
are collected on and in direct
contact with the Titanium Apatite
Photocatalytic Air-Purifying Filter.
For FTKS25/35D and 50/60G
Note: The FTKS71H uses 3 air filters and 3 Titanium
Apatite Photocatalytic Air-Purifying Filters.
For FTKS71H
Bacteria removal test
Testing method:
Dropping method
Testing organisation: Japan Spinners Inspecting Foundation
Result certificate:
No. 012553-1 and 012553-2
Effect of Titanium Apatite Photocatalyst
Adsorbs
Apatite adsorbs bacteria. At the
same time, the photocatalyst
oxidises odour components,
breaking them down.
Removes
Light
Odours
Bacteria
Decomposed
Deactivated
Titanium Apatite Photocatalyst
9
Mould-Proof Operation
When cooling or dry operation is stopped, fan-only
operation runs automatically for 1 hour. This airflow
dries the inside of the indoor unit to reduce the
generation of mould and odours. It is available with
FTKS25/35D.
Wipe-Clean Flat Panel
Flat panel models can be cleaned instantly
with a single wipe of a cloth across their
smooth surface. If more thorough cleaning is
required, the panel can also be easily
removed from the unit.
Conventional Front Grille Design
1. Difficult to remove dust on the
grille through wiping alone
2. Reduced capacity due to
increased suction resistance
Dust
Front grille design units
collect dust on their air
inlet grilles unless these
grilles are cleaned
regularly.
10
3. High sound levels due to
increased suction resistance
Comfortable Airflow
Vertical Auto-Swing (up and down)
Inverter Powerful Operation
Inverter Powerful Operation boosts cooling performance
for a 20-minute period. This is
convenient both when you first
turn on your air conditioner
and when you want to quickly
change the temperature
during operation.
Horizontal Auto-Swing (left and right)
3-D Airflow
Vertical Auto-Swing automatically moves the flaps up
and down and Horizontal Auto-Swing automatically
moves the louvres to the left and right. 3-D Airflow
combines Vertical and Horizontal Auto-Swing to circulate
air to every part of a room for uniform cooling of even
large spaces.
Comfort Airflow Mode
Comfort Airflow Mode prevents
uncomfortable drafts from blowing
directly on to your body. With
this function, when you press the
COMFORT button during
operation, the flap moves upward
to prevent direct cold drafts.
Horizontal Auto-Swing and 3-D Airflow
are available for FTKS50/60G and
71H.
Comfor Airflow Mode is available for FTKS71H
only.
Power-Airflow Dual Flaps
Wide-Angle Louvers
Power-Airflow Dual Flaps and Wide-Angle Louvres work
in tandem to precisely control both vertical and
horizontal airflow for distribution of air.
Indoor Unit On/Off Switch
The unit can be conveniently started
manually in the event the wireless
remote controller is misplaced or
the wireless remote controller
batteries are not charged.
Power-Airflow Dual Flaps
Indoor Unit On/Off Switch
Night Set Mode
Pressing the Off timer button automatically selects Night
Set Mode. This function prevents excessive cooling for
your pleasant sleep. Room temperature is raised by 0.5 C
after 60 minutes for cooling operation.
Cooling: the flaps flatten out during operation so that cool air slides off to
reach the corner of the room.
Wide-Angle Louvres
From a corner
to the centre
Covers even
a spacious room
+0.5 C
Set temp. before
Off timer begins
to operate
The louvres can be adjusted
by hand for FTKS25/35D
and with the wireless
remote controller for
FTKS50/60G and 71H.
Cooling
Time
60 minutes
Off timer turns on
Off timer stops air conditioner
Cooling operation: Room temperature is raised by 0.5 C after 60 minutes.
11
Lifestyle Convenience
Worry Free
Anticorrosion Treatment of Outdoor
Heat Exchanger Fins
Home Leave Operation
Home Leave Operation prevents large rises in the
indoor temperature by continuing operation* while you
are sleeping or out of your home. This means that an
air-conditioned welcome awaits when you wake or
return. It also means that the indoor temperature can
quickly return to your favourite comfort setting.
The outdoor unit’s heat exchanger fins are processed
using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the
fins’ resistance to acid rain and salt corrosion. A
hydrophilic film layer also prevents rust caused by the
run off of water droplets.
* Home Leave Operation can be set at any temperature from 18 to 32 C.
Home Leave Operation is available for FTKS50/60G.
Cross section of anticorrosion-treated fin
During operation, 23 C for the room
temperature setting, and 28 C for
the Home Leave setting.
Hydrophilic film
Aluminium
Corrosion-resistant
acrylic resin
23 C
Heat exchanger fin
One push!!
Start Home Leave
Operation simply by
pushing its button on the
remote controller.
Installation Flexibility
A long piping length gives installation flexibility.
Installation is possible even if there is no space for the
outdoor unit near the indoor unit.
28 C
FTKS25D/RKS25G
FTKS35D/RKS35G
When you are out of
your home, your air
conditioner prevents
large rises in the indoor
temperature by
continuing to operate
using Home Leave
Operation settings.
FTKS50G/RKS50G
FTKS60G/RKS60G
FTKS71H/RKS71H
23 C
Push again!!
When you return, you will
be greeted by an airconditioned room. Just
push the HOME LEAVE
button again to return to
your previous settings.
12
Max. piping length Max. height difference
25 m
15 m
30 m
20 m
Function Dictionary
Comfortable Airflow
Comfort Control
Indoor Unit Quiet Operation
Comfort Airflow Mode
Indoor unit operating sound levels are decreased by 2 or
3 dB (A) from the Low setting fan speed using the
wireless remote controller.
This function prevents uncomfortable drafts from blowing
directly on to the body. The flap changes the airflow
direction. To prevent drafts, the flap moves upward
during operation.
See page 8
See page 11
Outdoor Unit Quiet Operation
Outdoor unit operating sound levels are decreased by 3 dB
(A) from the rated operation sound using the wireless
remote controller.
Power-Airflow Dual Flaps
Power-Airflow Dual Flaps can flatten out during cooling
operation to deliver cool air to the corners of a room.
See page 8
See page 11
Intelligent Eye
Wide-Angle Louvres
Intelligent Eye with its infrared sensor automatically
controls air conditioner operation according to human
movement in a room. When there is no movement, it
adjusts the temperature by 2 C for energy savings.
The smoothly curved Wide-Angle Louvres provide wide
airflow coverage for effective operation no matter where
the indoor unit is placed in a room.
See page 11
See page 7
Vertical Auto-Swing (up and down)
Programme Dry Function
This function automatically moves the flaps up and down
to distribute air across a room.
This function automatically reduces the level of humidity.
See page 11
Auto Fan Speed
Horizontal Auto-Swing (left and right)
The microprocessor automatically controls fan speed to
adjust the room temperature to the set temperature.
Horizontal Auto-Swing automatically moves the louvres
to the left and right to cover a room with cool air.
See page 11
Timers
3-D Airflow
This function combines Vertical and Horizontal AutoSwing to circulate a cloud of cool air right to the corners
of even large spaces.
24-Hour On/Off Timer
This timer can be preset to start and stop at any time
within a 24-hour period. The air conditioner is started/
stopped simply by pressing the On/Off timer button on
the wireless remote controller.
See page 11
Lifestyle Convenience
Night Set Mode
Pressing the Off timer button automatically selects Night
Set Mode. This function prevents excessive cooling for
your pleasant sleep. Room temperature is raised by 0.5 C
after 60 minutes for cooling operation.
Econo Mode
This mode limits maximum running current to 70% and
power consumption to 50% to 70% of normal operation,
while maintaining maximum capacity at 60% to 80%. This
improves operating efficiency and also prevents circuit
breakers from being overloaded.
See page 11
See page 7
Worry Free
Inverter Powerful Operation
This function is convenient for boosting cooling performance
for a 20-minute period both when you first turn on your
air conditioner or want to quickly change the room
temperature.
Auto-Restart after Power Failure
The air conditioner memorises the settings for mode,
airflow, temperature, etc., and automatically returns to
them when power is restored after a power failure.
See page 11
Home Leave Operation
Self-Diagnosis with Digital Display
Home Leave Operation continues operation to prevent a
room from becoming too hot, while you are sleeping or
out of your home. Select any temperature from 18 to 32 C.
Malfunction codes are shown on the digital display panel
of the wireless remote controller for fast and easy
maintenance.
See page 12
Anticorrosion Treatment of Outdoor
Heat Exchanger Fins
Indoor Unit On/Off Switch
The unit can be conveniently started manually in the
event the wireless remote controller is misplaced or the
wireless remote controller batteries are not charged.
The outdoor unit’s heat exchanger fins are processed
using a special anticorrosion treatment. The surface is
covered with a thin acrylic resin layer to enhance the fins’
resistance to acid rain and salt corrosion.
See page 11
See page 12
13
Function List
Indoor Unit
Models
Cleanliness
Functions
FTKS FTKS FTKS
25/35D 50/60G 71H
DC Inverter
Titanium Apatite Photocatalytic
Air-Purifying Filter
Comfort Airflow Mode
Comfortable Airflow
This filter contains the new photocatalytic material
titanium apatite. While the filter’s micron-level fibres trap
dust, this photocatalyst adsorbs and decomposes
bacteria. The filter can be used for up to 3 years with
proper maintenance.
See page 9
Mould-Proof Operation
Mould-Proof Operation automatically runs fan-only
operation for 1 hour when cooling or dry operation is
stopped. This airflow prevents the generation of mould
and mould odours inside the indoor unit.
Power-Airflow
Dual Flaps
Wide-Angle Louvres
Vertical Auto-Swing
(up and down)
Horizontal Auto-Swing
(left and right)
3-D Airflow
Comfort Control
See page 10
Wipe-Clean Flat Panel
The flat panel models can be cleaned with only the single
pass of a cloth across their smooth surface. The flat
panel can also be easily removed for more thorough
cleaning.
Indoor Unit Quiet
Operation
Intelligent Eye
Programme Dry
Function
Auto Fan Speed
Cleanliness
Lifestyle Convenience
See page 10
Econo Mode
Inverter Powerful
Operation
Home Leave
Operation
Indoor Unit On/Off
Switch
Titanium Apatite
Photocatalytic
Air-Purifying Filter
Mould-Proof
Operation
Worry Free
Timers
Wipe-Clean Flat Panel
24-Hour On/Off Timer
Night Set Mode
Auto-Restart after
Power Failure
Self-Diagnosis with
Digital Display
Outdoor Unit
Models
Worry Comfort
Free Control
Functions
14
Outdoor Unit
Quiet Operation
Anticorrosion Treatment of Outdoor Heat
Exchanger Fins
RKS
RKS
25/35G 50/60G
RKS
71H
Easy-to-Use Wireless Remote Controller
Wireless remote controller for FTKS25/35D
Econo Mode
Selects fan speed and
Indoor Unit Quiet Operation
On/Off Switch
Sets room temperature
Selects mode: cooling, dry,
fan-only operation
Inverter Powerful Operation
Vertical Auto-Swing
(up and down)
Outdoor Unit Quiet Operation
Mould-Proof Operation
Intelligent Eye
Cancels On/Off Timer
24-Hour On Timer
Sets clock
24-Hour Off Timer
and Night Set Mode
Sets timer
Wireless remote controller for FTK50/60G
Home Leave Operation
On/Off Switch
Selects fan speed and
Indoor Unit Quiet Operation
Sets room temperature
Selects mode: cooling, dry,
fan-only operation
Inverter Powerful Operation
Vertical Auto-Swing
(up and down)
Outdoor Unit Quiet Operation
Horizontal Auto-Swing
(left and right)
Intelligent Eye
Cancels On/Off Timer
24-Hour On Timer
Sets clock
24-Hour Off Timer
and Night Set Mode
Sets timer
15
Wireless remote controller for FTKS71H
Econo Mode
Selects fan speed and
Indoor Unit Quiet Operation
On/Off Switch
Sets room temperature
Selects mode: cooling, dry,
fan-only operation
Inverter Powerful Operation
Vertical Auto-Swing
(up and down)
Outdoor Unit Quiet Operation
Intelligent Eye
Horizontal Auto-Swing
(left and right)
Comfort Airflow Mode
Cancels On/Off Timer
24-Hour On Timer
Sets clock
24-Hour Off Timer
and Night Set Mode
Sets timer
16
Specifications
FTKS25/35D
Model name
Capacity
Indoor unit
Outdoor unit
Rated (Min.-Max.)
kW
Btu/h
Power supply
Rated
A
Running current
W
Power consumption Rated (Min.-Max.)
Rated
W/W
COP
Indoor unit
Front panel colour
Airflow rate (H)
m3/min (cfm)
Fan speed
Sound levels (H/L/SL)
dB (A)
Dimensions (H x W x D)
mm
Machine weight
kg
Outdoor unit
Casing colour
Type
Compressor
W
Motor output
Refrigerant charge (R-410A)
kg
Sound levels (H/L)
dB (A)
Dimensions (H x W x D)
mm
Machine weight
kg
Operation range
CDB
Liquid
Piping
Gas
mm
connections
Drain
Max. piping length
m
Max. height difference
FTKS25DVM
RKS25GVMG
2.5 (1.2-3.2)
8,500 (4,050-10,900)
3.9
700 (295-1,050)
3.57
FTKS25DVM
8.7 (307)
37/25/22
RKS25GVMG
0.8
46/43
32
1 phase, 230 V, 50 Hz
White
5 steps, quiet and automatic
283 x 800 x 195
9
Ivory white
Hermetically sealed swing type
600
550 x 765 x 285
10 to 46
6.4
9.5
18.0
25
15
FTKS35DVM
RKS35GVMG
3.5 (1.4-4.0)
11,900 (4,750-13,650)
4.8
1,035 (300-1,400)
3.38
FTKS35DVM
8.9 (314)
39/26/23
RKS35GVMG
1.0
47/44
34
FTKS50/60G and 71H
Model name
Capacity
Indoor unit
Outdoor unit
Rated (Min.-Max.)
kW
Btu/h
Power supply
A
Running current
Rated
W
Power consumption Rated (Min.-Max.)
Rated
W/W
COP
Indoor unit
Front panel colour
Airflow rate (H)
m3/min (cfm)
Fan speed
Sound levels (H/L/SL)
dB (A)
Dimensions (H x W x D)
mm
Machine weight
kg
Outdoor unit
Casing colour
Type
Compressor
W
Motor output
Refrigerant charge (R-410A)
kg
Sound levels (H/L)
dB (A)
Dimensions (H x W x D)
mm
Machine weight
kg
Operation range
CDB
Liquid
Piping
Gas
mm
connections
Drain
Max. piping length
m
Max. height difference
FTKS50GVMG
RKS50GVMG
5.0 (1.7-6.0)
17,100 (5,800-20,500)
FTKS71HVMG
FTKS60GVMG
RKS71HVMG
RKS60GVMG
7.1 (2.3-8.5)
6.0 (2.3-6.7)
24,200 (7,800-29,000)
20,500 (7,800-22,900)
1 phase, 230 V, 50 Hz
6.2
9.2
7.8
1,400 (440-2,080)
2,100 (570-3,100)
1,780 (570-3,580)
3.57
3.38
3.37
FTKS50GVMG
FTKS60GVMG
FTKS71HVMG
White
14.7 (519)
21.5 (760)
17.4 (614)
5 steps, quiet and automatic
43/34/31
46/37/34
340 x 1,200 x 240
290 x 1,050 x 238
17
12
RKS50GVMG
RKS60GVMG
RKS71HVMG
Ivory white
Hermetically sealed swing type
1,920
1,100
1.5
1.7
2.3
54/49
52/49
47/44
735 x 825 x 300
770 x 900 x 320
47
55
71
10 to 46
6.4
9.5
12.7
15.9
18.0
30
20
Measurement conditions
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB; piping length 7.5 m.
2. Sound levels are based on the temperature conditions 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual
operation as a result of ambient conditions.
17
Options
Indoor unit
No.
1
2
3
4
Item
Wiring adaptor for time clock/remote controller
(Normal open pulse contact/normal open contact)
*2
*3
Titanium apatite photocatalytic air-purifying filter
Air-purifying filter with photocatalytic deodorising function *3
Remote controller loss prevention with chain
FTKS71H
FTKS50/60G
FTKS25/35D
KRP413AB1S
KAF970A48
KAF952B42
KAF970A46
KKF917A4
KKF910A4
Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
*2. The time clock and other devices should be obtained locally.
*3. The filter is a standard accessory. It should be replaced approximately every 3 years.
Titanium apatite photocatalytic
air-purifying filter
KAF970A46
Remote controller loss
prevention with chain
KKF917A4
Titanium apatite photocatalytic
air-purifying filter
KAF952B42
Titanium apatite photocatalytic
air-purifying filter
KAF970A48
Remote controller loss
prevention with chain
KKF910A4
Outdoor unit
No.
1
2
Item
Air direction adjustment grille
Drain plug
RKS25/35G
KPW937A4
Note: *1. One set includes 5 pieces for 5 units.
Air direction adjustment grille
KPW945A4
Drain plug
KKP937A4
RKS50/60G
KKP937A4
RKS71H
KPW945A4
*1
KKP945A4
Drain plug
KKP945A4
Control system
No.
1
2
3
4
Item
Central remote controller
Unified On/Off controller
Schedule timer
Interface adaptor for DIII-NET use
*1
*1
*1
FTKS25/35D
Note: *1. Interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
Central remote controller
DCS302CA61
Unified On/Off controller
DCS301BA61
FTKS50/60G
DCS302CA61
DCS301BA61
DST301BA61
KRP928BB2S
FTKS71H
Schedule timer
DST301BA61
Specifications are subject to change.
18
Warning
Daikin products are manufactured for export to numerous countries throughout the world. Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Cautions on product corrosion
1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
JMI-0107
Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING DIVISION
Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.
Scope of Registration:
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF
COMMERCIAL AIR CONDITIONING, HEATING, COOLING,
REFRIGERATING EQUIPMENT, HEATING EQUIPMENT,
RESIDENTIAL AIR CONDITIONING EQUIPMENT, HEAT
RECLAIM VENTILATION, AIR CLEANING EQUIPMENT,
COMPRESSORS AND VALVES.
Scope of Registration:
THE DESIGN/DEVELOPMENT
AND MANUFACTURE OF AIR
CONDITIONERS AND THE
COMPONENTS INCLUDING
COMPRESSORS USED FOR THEM
JQA-1452
DAIKIN AIRCONDITIONING (SINGAPORE) PTE. LTD.
No. 10 Ang Mo Kio Industrial Park II Singapore 569501
Tel. +65-6-5838888 Fax. +65-6-3497310 / 311
www.daikin.com.sg
Specifications, designs and other content appearing in this brochure are current as of August 2016 but subject to change without notice.
All of the Daikin Group’s business
facilities and subsidiaries in Japan
are certified under the ISO 14001
international standard for
environment management.