MODELS
LS454A CEILING MOUNT ONLY
20W IRC/12V (with gland fitted)
Rated IP67
1m
S
DI
110 C
o
A IMPORTANT INSTRUCTIONS
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
E sales@lumascape.com.au
W www.lumascape.com.au
For Installation LS464 and LSTE6
START
HERE
A.C.N. 010 572 773
Warning: The Luminaire should only be used complete with its protective shield (cover)
1a
NT
CO
WARNING: DO NOT USE POWER TOOLS TO ASSEMBLE OR FASTEN.
DO NOT REMOVE CABLE OR GLAND FROM FITTING
1b
72mm
20.5mm
TRANSFORMER
20.5mm
POWER
OUTLET
IN
If using LSTE6 transformer follow instructions
supplied with LSTE6 then go to step 2 - Otherwise...
Select a suitable 12V isolating type transformer and
locate centrally in relation to fixtures. Run cables.
Check cable sizes and Voltage Drop on chart over.
Refer warning over.
LID
ASSEMBLY
100mm
8mm
Mark locations of fixtures. Mark and drill/cast holes. Run supply cable through large
hole. Strip supply cable as above. See attached full sized template
UE
2
Cable Entry
Drill 28mm (1.10”)
clearance hole
for gland.
Drill holes to suit
mounting screws
3
4
D
SMALL
ORINGS
REFLECTOR
ASSEMBLY
Unscrew grub screw and
remove lid assembly. Remove reflector
assembly by gently levering tab between
bracket claws as shown.
6
lid
grub
screw
pocket
Isolate fixture from power. Unscrew grub
screw and remove lid assembly. Remove
lamp. To reassmble follow instructions 5
and 6.
www.lumascape.com.au
LUMASCAPE
HEAD OFFICE
T 07 3286 2299 F 07 3286 6599
Lumascape Lighting Industries ©2006
LUMASCAPE
SYDNEY - NSW
T 02 9519 6860 F 02 9519 8834
LUMASCAPE
MELBOURNE - VIC
T 03 9686 1900 F 03 9686 1700
H.I. LIGHTING
LUMASCAPE AGENT - WA
T 08 9321 5422 F 08 9321 5881
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SA
T 08 8232 0074 F 08 8232 0076
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
T 07 4031 4490 F 07 4031 5933
T
Check and clean all sealing areas.
Ensure Oring is in groove in lid. Re-Seal
fixture. Ensure that lid is pushed up as far
as possible so that oring seals. Grub
screws should be flush if fixture is
assembled correctly.
UC
Warning lamp is fragile take care when
installing - serious injury can result if lamp
is crushed. Insert lamp and test.
Avoid contact with bare lamp.
Avoid any contact with inside face of
reflector.
Relamping
o-ring
glass
o-ring
Terminate supply cable into terminal block
on reflector assembly. Gently push reflector
assembly into body ensuring bracket claws
are resting on the steps inside the body.
OD
5
For IP68 installation: Fit gland to fixture and
insert cable into gland and tighten. Secure fixture
with screws and orings supplied - do not use
power tools - screw by hand, to prevent
oring/gasket damage.
Note: Ensure gland is firmly tightened and
sealing areas are free from debris. Check that
oring is seated correctly. Use only round supply
cable and ensure that gland seals on outer
insulation.
PR
BODY
ASSEMBLY
STEP
ECC LIGHTING
LUMASCAPE AGENT - NZ
T 09 379 9680 F 09 308 9328
LUMASCAPE USA INC
Free Call 1-866-695-LUMA(5862)
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
C914 - 30/05/2010_REV-002
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
Tel (07) 3286 2299 Fax (07) 3286 6599 Email sales@lumascape.com.au
IMPORTANT INFORMATION
S
DI
C1721 - 2006_11_REV-002
IMPORTANT SAFETY INSTRUCTIONS
WARNING - To reduce the risk of FIRE or INJURY:
1. Luminaires and transformers to be installed by qualified installers only.
NT
CO
2. Luminaires to be used for intended purpose only. e.g Wall Mount fittings must be wall mounted.
3. Luminaires can become very hot. Use discretion in placement.
4. Do not touch hot lens, guard, or enclosure.
5. CAUTION - HOT SURFACE. Keep away from curtains and other combustible material.
6. Turn Off/Unplug and allow to cool before replacing lamp.
7. Keep lamp away from materials that may burn.
8. Never touch lamp with bare fingers. Oil from skin may damage lamp. Hold lamp with soft cloth when installing or replacing.
9. Do not operate the luminaires with a missing or damaged parts.
10. Replace any cracked protective shield
IN
11. Use only lamp type, voltage and wattage as specified by Lumascape on the product label.
12. Use only genuine Lumascape parts to replace damaged or missing components.
13. Luminaires supplied with Loctite Silver Grade Anti Seize lubricant on threads. Reapply if needed.
UE
14. Refer to instructions for installation and operating requirements.
15. Ensure installation complies with local regulations
SAVE THESE INSTRUCTIONS.
D
UC
OD
PR
T
LUMASCAPE
HEAD OFFICE - QLD
Tel (07) 3286 2299
Fax (07) 3286 6599
LUMASCAPE
SYDNEY - NSW
Tel (02) 9519 6860
Fax (02) 9519 8834
LUMASCAPE
MELBOURNE - VIC
Tel (03) 9686 1900
Fax (03) 9686 1700
www.lumascape.com.au
LUMASCAPE USA INC.
SAN FRANCISCO - CA
Tel 1-(650)-595-5862
Fax 1-(650) 595-5820
H.I. LIGHTING
LUMASCAPE AGENT - WA
Tel (08) 9321 5422
Fax (08) 9321 5881
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SAA
Tel (08) 8232
232 0074
Fax (08)
08) 8232 0076
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
Tel (07) 4031 4490
Fax (07) 4031 5933
ECC
C LIGHTING
GHTIN
LUMASCAPE AGENT - NZ
Tel (09) 379 9680
Fax
ax (09) 308 9328
Copyright
right ©2006 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
MODELS
S
DI
B
LS454A CEILING MOUNT ONLY
12V 35watt IRC max.
Rated IP67
1m
t 90 C
IMPORTANT INSTRUCTIONS
For Installation LS454A DOWNLIGHT
Warning: The Luminaire should only be used complete with its protective shield (cover)
A.C.N. 010 572 773
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
PO Box 1875, Cleveland D.C., QLD 4163, Australia
T 07 3286 2299
F 07 3286 6599
E sales@lumascape.com.au
W www.lumascape.com.au
NT
CO
WARNING: DO NOT USE POWER TOOLS TO ASSEMBLE OR FASTEN.
DO NOT REMOVE CABLE OR GLAND FROM FITTING
Mounting Template, 1:1
CL
Cable Entry
Drill/cast minimum
25mm (1”) diameter
clearance hole
for gland.
Drill to suit
mounting screws.
CL
20.5mm (0.81”)
UE
IN
102mm (4”)
20.5mm (0.81”)
D
100mm (2.5”)
8mm (3.175”)
T
SUPPLY CABLE STRIP LENGTH
www.lumascape.com.au
LUMASCAPE
HEAD OFFICE
T 07 3286 2299 F 07 3286 6599
Lumascape Lighting Industries ©2006
LUMASCAPE
SYDNEY - NSW
T 02 9519 6860 F 02 9519 8834
LUMASCAPE
MELBOURNE - VIC
T 03 9686 1900 F 03 9686 1700
H.I. LIGHTING
LUMASCAPE AGENT - WA
T 08 9321 5422 F 08 9321 5881
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SA
T 08 8232 0074 F 08 8232 0076
UC
OD
PR
72mm (2.83”)
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
T 07 4031 4490 F 07 4031 5933
ECC LIGHTING
LUMASCAPE AGENT - NZ
T 09 379 9680 F 09 308 9328
LUMASCAPE USA INC
Free Call 1-866-695-LUMA(5862)
T 1-(650)-595-LUMA(5862) 1-(650)-595-5820
C914 - 30/05/2010_REV-002
Lumascape Lighting Industries Pty Ltd
38-44 Enterprise Street, Cleveland, QLD 4163, Australia
Tel (07) 3286 2299 Fax (07) 3286 6599 Email sales@lumascape.com.au
VOLTAGEDROP
S
DI
CABLES
3.3mm2 Figure 8 PVC Cable
CABLE VOLTAGE DROP
NT
CO
4.2mm
6.3mm
5.4mm
12.5mm
9.5mm
LS604
13.8mm
LS604-6
20m
EXAMPLE 1
20W
LS604-10
Circuit 1
20W
EXAMPLE 1
Using drop cable only
20W
20W
20W
IN
TRANSFORMER
60m
20W
Circuit 3
20W
20W
20W
EXAMPLE 2
Using trunk and drop cable only
20W
D
LS604 DROP CABLE
6m max
LS604-10 TRUNK CABLE
This example shows the correct way to install
Lumascape luminaires using LS604-10
(10mm2) trunk cable. The total load on
Circuit 3 is 60W over 50 metres which is
shorter than the 54 metres allowed in the
Voltage Drop table. The load on Circuit 4 is
40W and using a doubled cable allows the
circuit to be up to 168 metres long.
PR
168m
TRANSFORMER
This example shows the correct way to install
Lumascape light luminaires using LS604
(3.3mm2) drop cable. The total load on
Circuit 1 is 60W over 20 metres as allowed
in the Voltage Drop table. The load on Circuit
2 is 40W and by using a doubled cable this
circuit can be 60 metres.
Circuit 2
UE
50m
EXAMPLE 2
Circuit 4
TABLE: VOLTAGE DROP
LOAD
DROP CABLE
3.3mm2 LS604
WATTAGE
SINGLE
DOUBLE
SINGLE
DOUBLE
20
70m
140m
105m
210m
40
30m
60m
55m
110m
50
25m
50m
44m
88m
60
20m
40m
36m
72m
70
15m
30m
30m
60m
80
14m
28m
27m
54m
46m
90
13m
26m
24m
48m
42m
100
12m
24m
21m
41m
36m
120
10m
20m
18m
36m
30m
150
7m
14m
15m
30m
26m
200
5m
10m
11m
22m
20m
250
4m
8m
9m
18m
17m
CAUTION
The distances and wattages shown are maximum and should not be exceeded.
www.lumascape.com.au
LUMASCAPE USA INC.
SAN FRANCISCO - CA
Tel 1-(650)-595-5862
Fax 1-(650) 595-5820
H.I. LIGHTING
LUMASCAPE AGENT - WA
Tel (08) 9321 5422
Fax (08) 9321 5881
SINGLE
DOUBLE
140m
280m
84m
168m
62m
124m
54m
108m
50m
0m
100m
92m
84m
72m
60m
52m
40m
34m
T
LUMASCAPE
MELBOURNE - VIC
Tel (03) 9686 1900
Fax (03) 9686 1700
10mm2 LS604-10
UC
LUMASCAPE
SYDNEY - NSW
Tel (02) 9519 6860
Fax (02) 9519 8834
TRUNK CABLE
6mm2 LS604-6
OD
LUMASCAPE
HEAD OFFICE - QLD
Tel (07) 3286 2299
Fax (07) 3286 6599
Excessive voltage drop causes lamps to
have a low light output. The following
charts and illustrations apply only to
Lumascape supplied cable. The distance
and wattage shown are maximum and
should not be exceeded.
10mm2 Figure 8 PVC Cable
6mm2 Figure 8 PVC Cable
LIGHTING PARTNERS AUSTRALIA
LUMASCAPE AGENT - SAA
Tel (08) 8232
232 0074
Fax (08)
08) 8232 0076
NQ LIGHTING
LUMASCAPE AGENT - NTH QLD
Tel (07) 4031 4490
Fax (07) 4031 5933
ECC
C LIGHTING
GHTIN
LUMASCAPE AGENT - NZ
Tel (09) 379 9680
Fax
ax (09) 308 9328
Copyright
right ©2006 Lumascape Lighting Industries Pty. Ltd. ABN 21 010 572 773
Download PDF