ATTENTION:
The motor of your Majestic® is thermally protected. If overheating occurs, it will
automatically stop running to prevent damage. If this occurs, shut power unit off and
remove cord from wall outlet. Let unit cool. This condition may be caused by obstructed
airflow. Check for a blockage in the attachment, hose or wand. The filters may also need
to be replaced. If you have checked for the above, and the condition persists, take the
unit to your local Authorized Service Center.
NOTE: The motor will resume operating once properly cooled.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY: Do not use perfume or alcohol-based liquids in the FilterQueen® Majestic®.
Use Genuine Health-Mor/FilterQueen® Fragrances sparingly – DO NOT SATURATE
scent pad. Use of non-genuine Health-Mor/FilterQueen® scents/fragrances in any
manner other than described in the owner’s manual could cause damage to your motor,
and will void your warranty.
This appliance can be used by children aged 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer or an
Authorized FilterQueen® Distributor.
TABLE OF CONTENTS:
Majestic® Parts........................................................................................................ 2 - 3
Air Scenting Chamber..................................................................................................4
Assembly/Operations....................................................................................................5
Power Nozzle.......................................................................................................... 6 - 7
Attachments............................................................................................................ 8 - 9
Changing the Filters...................................................................................................10
Warranty.....................................................................................................................11
Lifetime Service Benefit.............................................................................................11
For immediate service and information, your local Distributor is:
1
Majestic® – English
1
RATINGS
230V • 50Hz
800W w/o PN
950W w/PN
2&4
3
9
5
8
6
7
MAJESTIC® PARTS
1. On/Off Switch: Contains the international symbols “I” for ON and “0” for OFF.
2. Exhaust Cap: Remove to convert the Majestic® to an efficient blower.
3. Caution Light: Lights up when the motor has overheated. Motor automatically
shuts off to prevent damage. Turn the Majestic® off and unplug cord from wall.
Let unit cool. This condition is usually caused by an obstructed air flow. Check for
blockages in the hose, wand, or attachments. Filter may also need to be replaced. If
the problem persists, take the Majestic® to an Authorized Service Center.
4. Scent Chamber: Use one of the Majestic® Scents to freshen the air in your home
while you clean.
5. Suction Inlet: Use to connect hose to unit. Helps impart cyclonic action.
6. Clamp: Keeps an air tight seal between the power unit and dirt container, yet opens
quickly and easily.
7. Caster Set: Rubber ball casters roll smoothly on rugs or hard surfaces. Always
align one caster under suction inlet to prevent tipping.
8. Power Nozzle Outlet: Plug in for electric hose.
9. Attachment Crown: Holds four of the most essential cleaning attachments within
easy fingertip reach.
2
Majestic® – English
10
11
12
13
14
MAJESTIC® PARTS
10.Upholstery Nozzle and Brush: Remove embedded dirt from overstuffed
furniture, mattresses, and drapes.
11.Crevice Tool: Cleans hard-to-reach places.
12.Dusting Brush: Eliminates the need for a dust cloth.
13.10-inch (25.4 cm) Multipurpose Floor Brush: Cleans hardwood, tile,
linoleum, and other hard surfaced floors.
14.Power Nozzle Attachment Kit: Includes power nozzle, electric hose, and
power wand.
3
Majestic® – English
1
2
3
4
AIR-SCENTING CHAMBER
Using the air-scenting chamber
1. Remove exhaust cap on top of Majestic® with a slight turn to the left and lift off.
2. Mist the gray felt air-scent pad with one or two sprays of your desired Genuine
Health-Mor/FilterQueen® Fragrance.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR
INJURY: Do not use perfume or alcohol-based liquids in the FilterQueen® Majestic®.
Use Genuine Health-Mor/FilterQueen® Fragrances sparingly – DO NOT SATURATE
scent pad. Use of non-genuine Health-Mor/FilterQueen® scents/fragrances in any
manner other than described in the owner’s manual could cause damage to your motor,
and will void your warranty.
3. Close air-scent chamber by replacing cap and locking with a slight turn to right until
it locks into place.
4. Start power unit and resume cleaning. Within minutes you will notice the effects of
your Majestic® air-scenting chamber throughout the room.
4
Majestic® – English
1a
2a
1b
2b
ASSEMBLY AND OPERATION
For suction operation:
1a. Connect hose to suction inlet on dirt container by lining up arrow on hose with
metal pins on inlet and lock with a quarter turn to the right.
CAUTION: This hose contains electrical connections. DO NOT use to suck up water.
DO NOT immerse in water for cleaning. The hose should be checked regularly and
must not be used if damaged.
2a. Connect wand or cleaning attachment to hose by inserting male end into hose and
rotating it until the attachment or wand snaps into place.
3. Use accessories as recommended on the following pages.
For blowing operation:
1b. Remove the exhaust cap with a quarter turn to the left.
2b. Connect hose to inlet on top of unit by lining up arrow on hose with metal pins on
inlet and lock with a quarter turn to the right.
3. Connect wand or cleaning attachment to hose by inserting male end into hose and
rotating it until the attachment or wand snaps into place.
4. Use accessories as recommended on the following pages.
5
Majestic® – English
1
2
3
POWER NOZZLE
ATTACHING POWER NOZZLE:
1. Assemble for suction cleaning.
2. Connect wand to nozzle by pushing the female end of the wand over the male end of
the swivel neck of the nozzle until the locking button of the wand snaps into place.
The wand swivels more than 90 degrees allowing it to lie flat on the floor.
3. Plug cord extending from other end of hose into the outlet on the power unit.
PLEASE NOTE: The “ON/OFF” markings on the hose feature the international
symbols of “I” for ON and “O” for OFF. This switch only controls turning the power
nozzle on or off. To turn the power nozzle ON (for carpets) slide the switch to the most
forward position. To turn the power nozzle OFF (for wood, tile and linoleum floors)
slide the switch to the rear position.
NOTICE: This hose contains electrical wires and the cord extending from the other
end of the hose must be removed from the outlet on the power unit before cleaning
with attachments such as upholstery nozzle and brush, crevice tool, dusting brush and
multipurpose brush OR maintaining the appliance.
CLEANING WITH THE POWER NOZZLE
The Majestic® power nozzle requires no rug surface height adjustment. The shape of the
power nozzle body has been specially designed to allow it to be effective on any rug or
bare floor surface.
Use long, slow strokes when cleaning. For thicker rugs, use a criss-cross pattern to raise
nap and give them a fluffier appearance.
To clean stairs:
• Remove caster set from power unit.
• Set Majestic® on landing.
• Remove wand and connect hose handle directly to power nozzle.
STORAGE: Avoid sharp bends in hose by removing hose from the unit before storing.
CAUTION: Do not use on carpets or rugs with fringe or loose fibers.
6
Majestic® – English
A
A
B
A. PERIODIC MAINTENANCE:
Power Nozzle:
There are no user serviceable parts within the Majestic® power nozzle. Should any issue
arise that requires service, please contact your local FilterQueen® Distributor for service.
Note that your power nozzle roller brush must be replaced periodically in order to
maintain maximum cleaning performance. Contact your local FilterQueen® Distributor
for service.
Power Nozzle resettable curcuit breaker:
The circuit breaker is designed to protect the motor of the power nozzle from damage,
should it become clogged or the revolving brush stalls. To reset the circuit breaker, turn
off the Majestic® and unplug cord from wall outlet. Remove any foreign objects from
power nozzle and press the red button on the back of the nozzle. Plug Majestic® in and
resume use.
B. POWER UNIT CAUTION LIGHT:
When lit, the caution light indicates that the motor of the power unit has overheated. The
motor automatically shuts off to prevent damage. Turn Majestic® off and unplug cord
from wall. Let unit cool. This condition is usually caused by an obstructed air flow. Check
for blockages in the hose, wand, or attachments. Filters may also need to be replaced. If
the problem persists take the Majestic® to an Authorized Service Center.
7
Majestic® – English
A.
A.
B.
B.
ATTACHMENTS
A. THE DUSTING BRUSH
For easy dusting
Assemble Majestic® for suction cleaning.
Do all your general dusting with the round brush – it virtually eliminates your need for a
dust cloth. Use on highly-polished furniture, the most delicate cloth lampshades, or any
surface where dust accumulates.
For general room dusting: Attach brush directly to hose. Clean with gentle short strokes;
do not press down hard as this will seal the opening and cut off your cleaning power.
To clean brush: Run open end of hose over bristles of brush. If you have been dusting
grimy or very sooty surfaces, remove bristle assembly from rubber socket, wash in warm
soapy water; let dry before replacing.
B. CREVICE TOOL
For hard-to-reach places
Assemble Majestic® for suction cleaning.
Use crevice tool for removing dust and dirt behind cushions in upholstered furniture,
mattress tufts and bindings, bed springs, corners of drawers, radiators, and any other
place that’s hard to reach.
NOTE: When cleaning radiators, use crevice tool for suction first, but if coils are too
close together to reach the dirt, hang damp cloth or newspaper behind radiator, assemble
Majestic® for blowing and blow dust out onto cloth or paper.
Assembled for blowing, Majestic® unit and crevice tool may be used to defrost your
refrigerator, aerate rugs, or inflate party balloons.
8
Majestic® – English
A.
A.
B.
B.
ATTACHMENTS
A. 10-INCH (25.4 CM) MULTIPURPOSE FLOOR BRUSH
For hard floors and walls
Assemble Majestic® for suction cleaning.
Ideal for hard-surfaced floors such as tile, linoleum, wood, and concrete floors. The
10-inch (25.4 cm) multipurpose floor brush cleans a wide area with one simple stroke. To
deep-clean grooved surfaces, such as tile and hardwood, remove the brush insert. It is also
effective in cleaning walls, screens, ceilings, shades, or any flat surface.
NOTE: When cleaning wall surfaces, always work in a straight line from the bottom up.
To clean hard surfaces: Attach brush to end of wand and use in
same manner as the power nozzle.
To deep clean grooved hard surfaces: Remove brush insert and
reconnect attachment to end of wand.
To remove brush insert: Pull open flexible plastic corner while
lifting out brush insert (A-1). To reinsert brush, make sure short
bristles are in front and snap into place.
A-1
To clean brush: After each use, remove lint, threads, etc. by rubbing open end of hose
over brush. If brush is soiled, rinse in mild soap solution and let dry before using on lightcolored areas.
B. UPHOLSTERY NOZZLE AND BRUSH
For upholstery and drapes
Assemble Majestic® for suction cleaning.
To clean overstuffed furniture and mattresses: Use the nozzle without the brush to
remove deeply embedded dirt; use the nozzle with brush when fabric is covered with
threads, lint, etc.
To clean curtains and drapes: Attach wand to hose. For heavy drapes, attach nozzle
only directly to wand. For delicate curtains, use the nozzle and brush. Brush will prevent
delicate materials from being drawn into the nozzle.
9
Majestic® – English
A.
A.
B.
B.
A. CHANGING THE FILTER CONES
For best performance, replace cones as recommended by manufacturer:
t BioCone™ Filter – every month
t Medipure® – every 6 months
● Flat Disc Filter – every 6 months
CAUTION: DO NOT operate your power unit without Filter Cones in place.
BEWARE OF IMITATIONS: Use only Genuine Health-Mor/FilterQueen® Filter
Cones. Imitations can result in poor performance and cause damage to your unit.
1. Unplug power cord from wall and detach hose from power unit.
2. Release side clamps and remove power unit from dirt container.
3. Remove Medipure® Cone and set aside or discard if installing new cone.
4. Empty contents of dirt container into a large, open garbage bag. Allow contents of
container to fall including used BioCone™ Filter. Dirt container may be washed and
thoroughly dried to remove all dust and/or any odors.
5. Open a new BioCone™ Filter. Insert point of cone into filter cone locator in the bottom
of the dirt container. Be sure all edges of the cone are even with the gasket of the dirt
container.
6. Place the Medipure® Cone inside the BioCone™ Filter.
7. Replace power unit and lock side clamps in place. Be sure all three tabs of the
BioCone™ Filter are visible outside the power unit.
B. CHANGING THE FLAT DISC FILTER
1. Unplug power cord from wall and detach hose power unit.
2. Release side clamps and remove power unit from dirt container.
3. Remove the cone guard. Next, remove the Flat Disc Filter by pulling back the plastic
retainer ring with your finger and lifting it out.
4. Replace Flat Disc Filter. Place the filter over the center section of the screen. Replace
the retainer ring by squeezing ring. Make sure ring fits snugly under the three tabs of
the plastic screen. Replace the cone guard. Be sure the outer edge of the cone is seated
on the rubber lip around the circumference of the power unit and replace screw.
10
Majestic® – English
WARRANTY
Health-Mor warrants the Majestic Home Cleaning System canister unit, motor, hose, wand, power nozzle
and attachments to be free of defects in material and workmanship for five years from the date of purchase
and the power nozzle motor to be free of defects in material and workmanship for three years from the
date of purchase. This warranty does not cover: (1) use of the Majestic® for commercial, institutional,
professional, rental, or other non-household purposes; (2) ordinary wear items including but not limited to
brushes, belts, bearings, seals, and filters; (3) damage occurring through misuse or negligence; (4) damage
caused by use on a current or voltage other than stamped on the nameplate; (5) damage resulting from
service work performed by other than Health-Mor or its Authorized Distributors and/or Service Centers;
(6) cost of transportation, pick-up, delivery, house or service calls; and (7) damage caused from use of nongenuine parts and/or filters.
®
Health-Mor will repair or replace any defective parts under this warranty provided the Majestic®­ or
defective part is returned, transportation prepaid, with written proof of purchase date and serial number,
to the Authorized Distributor from whom it was purchased or to the Quality Assurance Department,
Health-Mor, 1 American Road, Suite 1250, Brooklyn, Ohio 44144, USA, or, with written authorization
from Health-Mor, to any other person authorized to perform warranty service. Information regarding other
persons authorized to perform warranty service can be obtained by calling the Health-Mor Consumer
Relations Department at 440-846-7800. If the Majestic® or part is found on inspection to be defective in
material or workmanship it will be repaired or replaced at the option of Health-Mor and returned to the
sender, freight or postage collect. No reimbursement will be made for the replacement of defective parts or
service performed during the warranty period if done by anyone other than the Authorized Distributor from
whom the Majestic® was purchased or by Health-Mor, without first having obtained written authorization
from Health-Mor.
This warranty is null and void and of no effect unless all the following conditions are met: (1) the Majestic®
was purchased from an Authorized Distributor of Health-Mor; (2) the manufacturer’s serial number for
the Majestic® has not been changed, defaced or removed; (3) The Majestic® has been used at all times in a
accordance with the instruction manual and has not been subject to abuse; (4) Only genuine FilterQueen®
filters and/or parts have been used with the Majestic®.
Any repair or replacement of a defect or defective part under this warranty will be warranted for one year
or until the end of the original warranty period, which ever is longer.
There is no other express warranty applicable to your Majestic®. Implied warranties, including warranties
or merchantability and fitness for a particular purpose, are limited in duration to the period of the time
during which the express warranty given herein is in effect. All consequential or other damages resulting
from breach of this warranty are excluded from coverage under this warranty.
Health-Mor does not assume or authorize anyone to assume any additional liability.
This warranty gives you specific legal rights and you may have other rights which vary from state to state.
The invalidation of any limitation of this warranty shall not affect the validity of the remaining portions.
LIFETIME SERVICE BENEFIT
Health-Mor agrees to rebuild or replace the motor of the Majestic® canister and/or the power nozzle motor
at any time after the expiration of the original warranty period, subject to the terms and conditions set
forth below.
1. The Majestic® must be in the possession of the original owner, must have been used for only household
purposes, and must be accompanied by proof of purchase. This service policy does not apply to any
Majestic® used for commercial, institutional, professional, rental or other non-household uses.
2. The Majestic® must be returned, transportation prepaid, to the Authorized Majestic® Distributor from
whom it was purchased, or to the Quality Assurance Department, Health-Mor, 1 American Road, Suite
1250, Brooklyn, Ohio 44144, USA. The owner must pay return transportation charges.
3. The Maximum charge for rebuilding the motor of the Majestic® canister will be $99 US Dollars and the
Maximum charge for rebuilding the power nozzle motor will be $29 US Dollars; this will include the
cost of all parts and labor necessary to restore the Majestic® motor and/or the power nozzle motor to the
correct operating order. A charge will be made at the then current prices for any parts missing from the
Majestic® at the time it is delivered for rebuilding, if such parts are necessary to restore the Majestic® to
correct operating condition and any parts needed or requested other than the canister motor and/or the
power nozzle motor.
11
Majestic® – English
4. If there is a defect in material or workmanship in the rebuilding, the Majestic® will be rebuilt again
at no charge, provided the Majestic® is returned within two years of the rebuilding to Health-Mor or
the Authorized Distributor who performed the rebuilding, transportation prepaid. Written proof of
the prior rebuilding must accompany the Majestic®.
5. The service agreement is void and inapplicable unless all of the following conditions are met:
a) The Majestic® was purchased from an Authorized Distributor;
b) Proof of Purchase must accompany the unit;
c) The manufacturer’s serial number for the Majestic® has not been changed, defaced or removed;
d) Damage to the power unit did not occur by reason of misuse, negligence, use on a current or
voltage other than that stamped on the nameplate or by use of other than genuine FilterQueen®
filter cones or parts.
WEEE Take-Back & Recycling
The EU Directive on Waste Electrical and Electronic Equipment (WEEE) requires that producers of
vacuum cleaners and air cleaners sold into EU countries:
1. label new vacuum and air cleaners to notify customers that it needs to be recycled
2. take back vacuum cleaners and air cleaners from customers at end of life, and
3. finance its recycling and reuse.
The WEEE Directive took effect on August 13, 2012, and manufacturers must have met target objectives
for recycling by February, 2014.
WEEE Compliance Statement
Through our Authorized Distributor, Health-Mor will take back vacuum cleaners and air cleaners for
recycling according to the individual EU country recycling requirements at end of product life.
12
Majestic® – English
Download PDF