DINB100-SA v2
EN
Standalone Biometric Reader
v. c3
USER’S MANUAL
www.xprgroup.com
1
CONTENS
3
3
4
4
4
4
5
5
1. INTRODUCTION
2. MOUNTING
3. SPECIFICATIONS
4. APPLICATION DIAGRAM
5. RECOMMENDED SWIPING TECHNIQUE
6. INDICATION
7. WIRING
8. ADDING ADMIN FINGER
9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing dinb100-sa with dinrtt
Pairing dinb100-sa with rtt
Pairing dinb100-sa with ru2
6
6
6
6
7
7
7
7
7
8
8
8
9
10. ADMINISTRATOR PROGRAMMING
Add finger relay 1
Add finger relay 2
Add finger relay 1&2
Delete finger
Delete all fingers
Change admin finger
Change installer finger
Administrator programming block diagram
Installer programming block diagram
10
10
10
10
10
11
12. ADMINISTRATOR PROGRAMMING BY KEYPAD
12
13. INSTALLER PROGRAMMING BY KEYPAD
14
11. INSTALLER PROGRAMMING
Set relay 1 time
Set relay 2 time
Buzzer on/off
Backlight on/off
www.xprgroup.com
2
1. INTRODUCTION
DINB100-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The
scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor
reducing to minimum the need to repeat finger swiping at the sensor.
The reader can store up to 100 finger templates. One template is reserved for User manager (Administrator), one
template is reserved for Reader configuration (Installer) and up to 98 templates are for Users.
RECOMMENDATIONS
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can
increase the security of the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he
leaves the site to enroll your finger as administrator.
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips,
making difficult for the sensor to recognize correctly the fingerprint. In most cases, these are children and older persons. To
solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use
chemicals and materials that can scratch the sensor.
WARNING!
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or
construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint.
If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled
according to all national laws and regulations.
2. MOUNTING
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can’t be entered.
The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the
temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended
to install the reader inside a third party sealed wall mount box (fitted with additional heater if very low temperature) to keep
a constant sensor level performance. XPR™ cannot guarantee the functionality of the product if measures and advice before
are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security
but also the possibility to use different readers depending on users.
www.xprgroup.com
3
3. SPECIFICATIONS
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
98 templates
1 x Relay (2 A /24V AC/DC)
Yes
Pulse (1 to 30 seconds) or Toggle(ON/OFF)
Finger (basic installation)
Programming:
Admin/Installer Fingers:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
Finger or Card (when used with card reader DIN Card reader)
Finger or PIN code (when used with keypad DINPAD-M)
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes
via RS485 converter and windows application
100 mA max.
9-14 V DC
Tricolor Status LED
IP40
-20°C to +50°C
5% to 93% RH without condensation
80 x 80 x 9
DINB100-SA v2
4. APPLICATION DIAGRAM
5. RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping. Starting from the first finger joint,
place the selected finger on the swipe sensor and move it evenly towards oneself in one
steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
6. INDICATION
Tricolor Status LED
Green - Access Granted
Red - Access denied
Orange - Idle Mode
OK Beep - short + long beep
Error Beep - 3 short beeps
Swipe Finger - 2 short beeps
www.xprgroup.com
4
7. WIRING
Relay Output
NC
C
NO
NC
Jumper (Adding Master Finger)
C
NO
Connection to additional
card reader or keypad
12V
GND
B
A
PB
DINB100-SA v2
GND
tamp
tamp
+12V
GND
B
A
PB
GND
tamp
tamp
Power Supply
(9-14V DC)
Rs485
Push Button
Tamper
Electric Door Strike
(DC powered)
-
12V
GND
12V
1N4007
+
GND
C
NO
B
NC
A
C
PB
PB
NO
GND
tamp
tamp
tamp
tamp
Alarm
+
-
12 VDC
8. ADDING ADMIN FINGER
DINB100-SA
1. Close the jumper on the back of the device.
2. Reset the Power of the device.
12/24V AC/DC
A
B
GND
12V
3. Wait for One long + multiple short beeps
4. Open the jumper. (short beeps will stop)
5. Wait for about 15 seconds for the LED to blink in Orange.
6. Swipe the Master finger min.6 times. (Until Ok Beep)
x6
Warning: This procedure also deletes all the users and the installer finger.
Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)
www.xprgroup.com
5
9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of
request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual.
Pairing DINB100-SA with DINRTT
No1
DINRTT
12
-
1. Close the Jumper. DINRTT beeps continuously and
the red led blinks.
COM
-
DINB100-SA v2
+
1N4007
12 VDC +
No2
COM
Nc2
No1
Nc1
COM
2. Open the Jumper
GND
Tamp
3. Wait for Beep + OK Beep (short + short + long beep)
A
Tamp
Pb1
12V
B
+12V
GND
GND
+12V
+12V
GND
GND
+12V
A B
+12V
Pb
1
Exit Button
(NO)
A B
GND
Rs485
-
max. 50 meters
After the OK beep, the coupling is done.
Rs485
GND
GND
Pb2
B
GN
D
A
+
12 VDC
Pairing DINB100-SA with RTT
1N4007
12 VDC +
DINB100-SA
+
1. Put Dipswitch No.1 to position ON. RTT
beeps continuously and the red ledblinks.
-
COM
No
-
2. Put Dipswitch No.1 to position OFF.
RTT
ON
3. Wait for Beep + OK Beep (short + short +
long beep)
12
GND
After the OK beep, the coupling is done.
12V
+12V
GND
+12V
A B
B
GND
A
A B
Rs485
max. 50 meters
-
+
12 VDC
1N4007
Pairing DINB100-SA with RU2
NO
+
1
-
COM
2
Ru2
+
12 VDC
DINB100-SA v2
Pink A (RS485)
Violet B (RS485)
max. 50 meters
GND
+12V
+12V
GND
1. Put the Jumper to closed position. RU2
beeps continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
www.xprgroup.com
6
10. ADMINISTRATOR PROGRAMMING
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers.
Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in
installer manual.
ADD Finger Relay 1 (Finger that will activate relay 1)
Action
Swipe Admin Finger 1 time
Finger
Backlight
slow blinking
x1
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
Buzzer Sound
short beep
short beep
x6
fast blinking
short + long beep
fast blinking
short + long beep
or
x1
Present card/tag 1 time
ADD Finger Relay 2 (Finger that will activate relay 2)
Action
Swipe Admin Finger 2 times
Finger
Backlight
slow blinking
x2
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
Buzzer Sound
short beep
short beep
x6
fast blinking
short + long beep
fast blinking
short + long beep
or
x1
Present card/tag 1 time
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
Action
Swipe Admin Finger 3 times
Finger
Backlight
slow blinking
x3
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
Buzzer Sound
short beep
short beep
x6
fast blinking
short + long beep
fast blinking
short + long beep
or
Present card/tag 1 time
x1
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
www.xprgroup.com
7
DELETE Finger
Action
Swipe Admin Finger 4 times
Finger
Backlight
slow blinking
x4
Wait 5 seconds (until fast blinking)
Swipe User Finger
Buzzer Sound
short beep
short beep
x1
fast blinking
short + long beep
fast blinking
short + long beep
or
x1
Present card/tag 1 time
DELETE ALL Fingers and Cards
Action
Swipe Admin Finger 4 times
Finger
x4
Wait 5 seconds (until fast blinking)
Swipe Admin Finger 2 times
x2
Backlight
Buzzer Sound
slow blinking
short beep
slow blinking
short beep
fast blinking
multiple beeps
Backlight
Buzzer Sound
CHANGE ADMIN Finger
Action
Swipe Admin Finger 5 times
Finger
x5
Wait 5 seconds (until fast blinking)
Swipe NEW Admin Finger
min.6 times
x6
slow blinking
short beep
slow blinking
short beep
fast blinking
short + long beep
CHANGE INSTALLER Finger
Action
Swipe Admin Finger 6 times
Finger
x6
Wait 5 seconds (until fast blinking)
Swipe NEW Installer Finger
min.6 times
x6
Backlight
Buzzer Sound
slow blinking
short beep
slow blinking
short + long beep
fast blinking
3 short beeps
CONNECTING DINB100 WITH DINMTPX PROXIMITY READER
Connect both devices with the cable provided.
The proximity reader will be powered via that
cable. No extra power supply for the proximity
reader is needed. Once connected, no further
settings are needed.
www.xprgroup.com
8
Administrator Programming block diagram
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
1 swipe
2 swipes
3 swipes
4 swipes
5 swipes
ADD Finger
ADD Finger
ADD Finger
DELETE FINGER
INSTALLER
Finger
(on board)
(remote)
ADMIN
Finger
Wait
5 seconds
Wait
5 seconds
Wait
5 seconds
Wait
5 seconds
Relay 1
(until fast blinking)
SWIPE
new finger
Relay 2
(until fast blinking)
SWIPE
new finger
Relay 1&2
Wait
5 seconds
(until fast blinking)
SWIPE
new finger
Change
Wait
5 seconds
(until fast blinking)
SWIPE
already enrolled
finger
min. 6 times
min. 6 times
or
present
card/tag
or
present
card/tag
or
present
card/tag
or
present
card/tag
END
END
END
END
min. 6 times
1 time
Wait
5 seconds
(until fast blinking)
SWIPE
(until fast blinking)
SWIPE
ADMIN finger
2 times
to
DELETE ALL
new ADMIN
FINGER
END
END
min. 6 times
6 swipes
Enroll
(until fast blinking)
SWIPE
new
INSTALLER
FINGER
min. 6 times
END
Only in combination
with DINRTT and RU2
www.xprgroup.com
9
11. INSTALLER PROGRAMMING
Set Relay 1 Time
Action
Swipe Installer Finger 1 time
Finger
x1
Backlight
slow blinking
Wait 5 seconds (until fast blinking)
Swipe the INSTALLER Finger
and start counting seconds
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
Buzzer Sound
short beep
short beep
x1
x1
fast blinking
beeps on 1 second
fast blinking
short + long beep
Set Relay 2 Time
Action
Swipe Installer Finger 2 times
Finger
x2
Backlight
slow blinking
Wait 5 seconds (until fast blinking)
Swipe the INSTALLER Finger
and start counting seconds
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
Buzzer Sound
short beep
short beep
x1
x1
fast blinking
beeps on 1 second
fast blinking
short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
BUZZER ON/OFF
Action
Swipe Installer Finger 3 times
Finger
x3
Backlight
slow blinking
Wait 5 seconds (until fast blinking)
Swipe Installer Finger
Buzzer Sound
short beep
short beep
x1
fast blinking
short + long beep
BACKLIGHT ON/OFF
Action
Swipe Installer Finger 4 times
Finger
x4
Backlight
slow blinking
Wait 5 seconds (until fast blinking)
Swipe Installer Finger
Buzzer Sound
short beep
short beep
x1
fast blinking
www.xprgroup.com
short + long beep
10
Installer Programming block diagram
Swipe the Installer Finger 1 to 4 times depending of the desired menu
1 swipe
2 swipes
3 swipes
4 swipes
Set
RELAY 1
Set
RELAY 2
BUZZER
ON/OFF
BACKLIGHT
(on board)
Time
(remote)
Wait
5 seconds
Wait
5 seconds
Wait
5 seconds
Wait
5 seconds
Time
ON/OFF
(until fast blinking)
(until fast blinking)
(until fast blinking)
(until fast blinking)
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to put the Buzzer ON/OFF
Swipe the Installer Finger
to put the Backlight
ON/OFF
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
END
END
END
END
Only in combination
with DINRTT and RU2
www.xprgroup.com
11
12. ADMINISTRATOR PROGRAMMING BY KEYPAD
Programming by keypad can be done only if the DINB100-SA V2 reader is connected to keypad DINPAD-M as shown
in the pictures bellow. The connection is done by the cable provided with the biometric reader. Once connected,
the keypad must be put in slave mode.
Connect both devices with the cable provided.
Put the keypad in slave mode:
Press B (3 seconds) + 000000
Press 0
Press 2
Press A to exit
Reset the device
Note: In some previous versions of our keypads,
you can enter the menu only by pressing B +
000000. Please refer to the Keypad’s Manual.
www.xprgroup.com
12
ADMINISTRATOR PROGRAMMING BY KEYPAD
ENTER ADMIN CODE
Press 0A to exit the Menu
ADD
User
DELETE
User
1
2
RELAY 1
RELAY 2
(remote)
RELAY
1&2
1
2
3
(on board)
DELETE
Finger
1
ENROLL
Installer Finger
or PIN Code
4
5
DELETE
PIN Code
CONFIRM
ADD
Finger
2
7
Press “A”
PIN Code
Location
1
2
01-97
01-97
FINGER
Location
PIN Code
Location
Press “A”
Press “A”
01-97
01-97
multiple beeps
FINGER
Location
Press “A”
ENROLL
Admin Finger
or PIN Code
3
ADD
PIN Code
Note: Entering this menu is done by
admin PIN Code. You can not enter
with Admin Finger.
MENU
DELETE
ALL
Users
ADD
Finger
Press “A”
default: 1234+A
ADD
PIN Code
ADD
PIN Code
1
2
ADD
Finger
Press “A”
Press “A”
Press “A”
Press “A”
ENROLL
Finger
Swipe
the finger
min.
PRESS
the
PIN Code
ENROLL
Finger
Swipe
the finger
min.
PRESS
the
PIN Code
6 times
1 to 8
digits
1
6 times
6 times
1 to 8
digits
x6
x6
Press “A”
ENROLL
Finger
Swipe
the finger
min.
2
Press “A”
PRESS
the
PIN Code
1 to 8
digits
x6
Exit
Press “A”
Note: The Fingerprint can be
deleted by keypad, only if it is
enrolled with keypad.
Press 0A to exit the Menu
Example 1: Add user finger to Relay1 - Press 1234 + A + 1 + 1 + 1 + 01 + A + Enroll finger 6 times. 0A to exit.
Example 2: Add user PIN 147 to Relay2 - Press 1234 + A + 1 + 2 + 2 + 02 + A + 147 + A. 0A to exit.
www.xprgroup.com
13
13. INSTALLER PROGRAMMING BY KEYPAD
ENTER INSTALLER CODE
default: 5678+A
Press 0A to exit the Menu
Note: Entering this menu is done by
installer PIN Code. You can not enter
with Installer Finger.
MENU
Set Relay 1
TIME
Set Relay 2
TIME
Buzzer
ON/OFF
Backlight
ON/OFF
(on board)
1
(remote)
3
4
Press
01 to 30 for
time in seconds
or
00 for toggle
(ON/OFF) Mode
Press
01 to 30 for
time in seconds
or
00 for toggle
(ON/OFF) Mode
0 = OFF
1 = ON
0 = OFF
1 = ON
Press “A”
Press “A”
Press “A”
Press “A”
2
Press 0A to exit the Menu
Example: Change relay1 time to 2 seconds - 5678 + A + 1 + 02 + A.
www.xprgroup.com
14
www.xprgroup.com
15
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS2 directive EN50581:2012
www.xprgroup.com
16