XprAccess DINB100-SA v2 fingerprint reader, DINRTT, RU2 remote relay unit, DIN card reader, DINPAD M keypad User manual
Below you will find brief information for fingerprint reader DINB100-SA v2, remote relay unit DINRTT, remote relay unit RU2. The DINB100-SA v2 is a standalone biometric reader that can be used to control access to a door or other secured area. It can be paired with a remote relay unit for increased security and can be used with optional card reader and keypad for added functionality. The reader stores up to 100 fingerprints and can be programmed to control one or two relays. It also has a tamper switch for extra security.
Advertisement
Advertisement
DINB100-SA v2
EN
Standalone Biometric Reader
USER’S MANUAL
www.xprgroup.com
1
CONTENS
1. INTRODUCTION
2. MOUNTING
3. SPECIFICATIONS
4. APPLICATION DIAGRAM
5. RECOMMENDED SWIPING TECHNIQUE
6. INDICATION
7. WIRING
8. ADDING ADMIN FINGER
9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing dinb100-sa with dinrtt
Pairing dinb100-sa with rtt
Pairing dinb100-sa with ru2
10. ADMINISTRATOR PROGRAMMING
Add finger relay 1
Add finger relay 2
Add finger relay 1&2
Delete finger
Delete all fingers
Change admin finger
Change installer finger
Administrator programming block diagram
11. INSTALLER PROGRAMMING
Set relay 1 time
Set relay 2 time
Buzzer on/off
Backlight on/off
Installer programming block diagram
12. ADMINISTRATOR PROGRAMMING BY KEYPAD
13. INSTALLER PROGRAMMING BY KEYPAD
www.xprgroup.com
7
7
7
7
7
8
9
8
8
6
6
6
6
5
5
4
4
4
4
3
3
10
10
11
10
10
10
12
14
2
1. INTRODUCTION
DINB100-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor reducing to minimum the need to repeat finger swiping at the sensor.
The reader can store up to 100 finger templates. One template is reserved for User manager (Administrator), one template is reserved for Reader configuration (Installer) and up to 98 templates are for Users.
RECOMMENDATIONS
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as administrator.
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can scratch the sensor.
WARNING!
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint.
If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled according to all national laws and regulations.
2. MOUNTING
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipments.
If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can’t be entered.
The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fitted with additional heater if very low temperature) to keep a constant sensor level performance. XPR™ cannot guarantee the functionality of the product if measures and advice before are not followed.
It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use different readers depending on users.
www.xprgroup.com
3
3. SPECIFICATIONS
Fingerprint Capacity:
Output:
Push Button Input:
Door Open Time:
Entry Mode:
Programming:
Admin/Installer Fingers:
Backlight ON/OFF:
Buzzer ON/OFF:
Firmware upgrade:
Current Consumption:
Power Supply:
Indication:
IP Factor:
Storage/Operating Temperature :
Storage/Operating Humidity:
Dimensions(mm):
98 templates
1 x Relay (2 A /24V AC/DC)
Yes
Pulse (1 to 30 seconds) or Toggle(ON/OFF)
Finger (basic installation)
Finger or Card (when used with card reader DIN Card reader)
Finger or PIN code (when used with keypad DINPAD-M)
By swiping
1 Administrator and 1 Installer Finger
Yes
Yes via RS485 converter and windows application
100 mA max.
9-14 V DC
Tricolor Status LED
IP40
-20°C to +50°C
5% to 93% RH without condensation
80 x 80 x 9
4. APPLICATION DIAGRAM
DINB100-SA v2
5. RECOMMENDED SWIPING TECHNIQUE
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result:
For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
6. INDICATION
Tricolor
Status
LED
Green - Access Granted
Red - Access denied
Orange - Idle Mode
OK Beep - short + long beep
Error Beep - 3 short beeps
Swipe Finger - 2 short beeps www.xprgroup.com
4
7. WIRING
Relay Output
NC
NO
NC
C
NO
Jumper (Adding Master Finger)
Connection to additional card reader or keypad
DINB100-SA v2
Electric Door Strike
(DC powered)
-
+
C
NO
NC
C
NO
12V
GND
B
A
PB
GND tamp tamp tamp tamp
12V
GND
PB
12V
GND
B
A
PB
GND tamp tamp
+12V
GND
B
A
PB
GND tamp tamp
Power Supply
(9-14V DC)
Rs485
Push Button
Tamper
Alarm
+
-
12 VDC
8. ADDING ADMIN FINGER
1. Close the jumper on the back of the device.
2. Reset the Power of the device.
3. Wait for One long + multiple short beeps
4. Open the jumper. (short beeps will stop)
12/24V AC/DC
5. Wait for about
15 seconds
for the LED to blink in
Orange
.
6. Swipe the Master finger
min.6 times.
(Until Ok Beep)
Warning:
This procedure also deletes all the users and the installer finger.
Warning:
This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)
x 6
www.xprgroup.com
DINB100-SA
A B GND 12V
5
9. PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual.
Pairing DINB100-SA with DINRTT
DINB100-SA v2
12 VDC
DINRTT
+
-
12
1. Close the Jumper. DINRTT beeps continuously and
the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
A B GND 12V
A B
Exit Button
(NO)
+12V
GND
Rs485 max. 50 meters
GN
D
Pb1
GND
Pb1
GND
Pb2
-
+
12 VDC
Rs485
Tamp
Tamp
A B
Pairing DINB100-SA with RTT
12 VDC
+
-
DINB100-SA
RTT
ON
12
1. Put Dipswitch No.1 to position ON. RTT
beeps continuously and the red ledblinks.
2. Put Dipswitch No.1 to position OFF.
3. Wait for Beep + OK Beep (short + short +
long beep)
After the OK beep, the coupling is done.
A B GND 12V
A B
+12V
GND max. 50 meters
Rs485
-
+
12 VDC
A B
Pairing DINB100-SA with RU2
Ru2
NO COM
+
-
+
-
12 VDC
1
2
1. Put the Jumper to closed position. RU2
beeps continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short + long
beep)
After the OK beep, the coupling is done.
DINB100-SA v2
Pink A
(RS485)
Violet B
(RS485)
max. 50 meters
GND
+12V
+12V
GND
Warning:
Changing the ADMIN finger will also unpair the remote relay unit.
www.xprgroup.com
6
10. ADMINISTRATOR PROGRAMMING
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers.
Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in installer manual.
ADD Finger Relay 1 (Finger that will activate relay 1)
Action
Swipe Admin Finger 1 time
Finger
x 1
Backlight
slow blinking
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
or
x 6 fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound
short beep short beep short + long beep short + long beep
ADD Finger Relay 2 (Finger that will activate relay 2)
Action
Swipe Admin Finger 2 times
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
or
Finger
x 2 x 6
Backlight
slow blinking fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound
short beep short beep short + long beep short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
Action
Swipe Admin Finger 3 times
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
or
Finger
x 3 x 6
Backlight
slow blinking fast blinking
Present card/tag 1 time x 1 fast blinking
Buzzer Sound
short beep short beep short + long beep short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
www.xprgroup.com
7
DELETE Finger
Action
Swipe Admin Finger 4 times
Wait 5 seconds (until fast blinking)
Swipe User Finger
or
Present card/tag 1 time
Finger
x 4 x1 x 1
DELETE ALL Fingers and Cards
Finger Action
Swipe Admin Finger 4 times
Wait 5 seconds (until fast blinking)
Swipe Admin Finger 2 times x 4 x2
CHANGE ADMIN Finger
Action
Swipe Admin Finger 5 times
Finger
x 5
Wait 5 seconds (until fast blinking)
Swipe NEW Admin Finger min.6 times x6
CHANGE INSTALLER Finger
Finger Action
Swipe Admin Finger 6 times
Wait 5 seconds (until fast blinking)
Swipe NEW Installer Finger min.6 times x 6 x6
CONNECTING DINB100 WITH DINMTPX PROXIMITY READER
Backlight
slow blinking fast blinking fast blinking
Backlight
slow blinking slow blinking fast blinking
Backlight
slow blinking slow blinking fast blinking
Backlight
slow blinking slow blinking fast blinking
Connect both devices with the cable provided.
The proximity reader will be powered via that cable. No extra power supply for the proximity reader is needed. Once connected, no further settings are needed.
Buzzer Sound
short beep short beep short + long beep short + long beep
Buzzer Sound
short beep short beep multiple beeps
Buzzer Sound
short beep short beep short + long beep
Buzzer Sound
short beep short + long beep
3 short beeps www.xprgroup.com
8
Administrator Programming block diagram
Swipe the
ADMIN
Finger 1 to 6 times depending of the desired menu
1
swipe
ADD Finger
Relay 1
(on board)
2
swipes
ADD Finger
Relay 2
(remote)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
3
swipes
ADD Finger
Relay 1&2
Wait
5 seconds
(until fast blinking)
SWIPE new finger min. 6 times or present card/tag
END
SWIPE new finger min. 6 times or present card/tag
END
SWIPE new finger min. 6 times or present card/tag
END
Only in combination with DINRTT and RU2
4
swipes
DELETE FINGER
5
swipes
Change
ADMIN
Finger
6
swipes
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
SWIPE already enrolled finger
1 time or present card/tag
SWIPE
ADMIN finger
2 times to
DELETE ALL
END
END
SWIPE new ADMIN
FINGER min. 6 times
END
SWIPE new
INSTALLER
FINGER min. 6 times
END
www.xprgroup.com
9
11. INSTALLER PROGRAMMING
Set Relay 1 Time
Action
Swipe Installer Finger 1 time
Wait 5 seconds (until fast blinking)
Swipe the INSTALLER Finger and start counting seconds
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode
Finger
x1 x1 x1
Backlight
slow blinking fast blinking fast blinking
Buzzer Sound
short beep short beep beeps on 1 second short + long beep
Set Relay 2 Time
Action
Swipe Installer Finger 2 times
Finger Backlight Buzzer Sound
short beep x2 slow blinking
Wait 5 seconds (until fast blinking)
Swipe the INSTALLER Finger and start counting seconds
Swipe the INSTALLER Finger to stop or wait 30 seconds to put the relay in toggle mode x1 x1 fast blinking fast blinking short beep beeps on 1 second short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
BUZZER ON/OFF
Action
Swipe Installer Finger 3 times
Wait 5 seconds (until fast blinking)
Swipe Installer Finger
Finger
x3 x1
Backlight
slow blinking fast blinking
Buzzer Sound
short beep short beep short + long beep
BACKLIGHT ON/OFF
Action
Swipe Installer Finger 4 times
Wait 5 seconds (until fast blinking)
Swipe Installer Finger
Finger
x4 x1
Backlight
slow blinking fast blinking
Buzzer Sound
short beep short beep short + long beep www.xprgroup.com
10
Installer Programming block diagram
Swipe the
Installer
Finger 1 to 4 times depending of the desired menu
1
swipe
Set
Time
(on board)
2
swipes
Set
Time
(remote)
3
swipes
4
swipes
Swipe the Installer Finger and start counting seconds
Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger and start counting seconds
Swipe the Installer Finger to stop or wait 30 seconds to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger to put the Buzzer ON/OFF
END END
Only in combination with DINRTT and RU2
END
Swipe the Installer Finger to put the Backlight
ON/OFF
END
www.xprgroup.com
11
12. ADMINISTRATOR PROGRAMMING BY KEYPAD
Programming by keypad can be done only if the DINB100-SA V2 reader is connected to keypad DINPAD-M as shown in the pictures bellow. The connection is done by the cable provided with the biometric reader. Once connected, the keypad must be put in slave mode.
www.xprgroup.com
Connect both devices with the cable provided.
Put the keypad in slave mode:
Press B (3 seconds) + 000000
Press 0
Press 2
Press A to exit
Reset the device
Note:
In some previous versions of our keypads, you can enter the menu only by pressing B +
000000. Please refer to the Keypad’s Manual.
12
ADMINISTRATOR PROGRAMMING BY KEYPAD
ENTER ADMIN CODE
default:
1234+A
Note: Entering this menu is done by admin PIN Code. You can not enter with Admin Finger.
Press 0A to exit the Menu
MENU
ADD
User
1
RELAY 1
(on board)
1
RELAY 2
(remote)
2
RELAY
1 & 2
3
ADD
Finger
1
ADD
PIN Code
2
FINGER
Location
01-97
PIN Code
Location
01-97
DELETE
User
2
DELETE
Finger
1
DELETE
PIN Code
2
FINGER
Location
PIN Code
Location
01-97 01-97
Press “A” Press “A”
DELETE
ALL
Users
3
CONFIRM
7
Press “A”
4
ADD
Finger
1
ADD
PIN Code
2
5
ADD
Finger
1
ADD
PIN Code
2
Press “A” Press “A” Press “A” Press “A”
Press “A” Press “A”
ENROLL
Finger
Swipe the finger
6 times
x 6
PRESS the
PIN Code
1 to 8 digits
Press “A”
ENROLL
Finger
Swipe the finger
6 times
x 6
PRESS the
PIN Code
Press “A”
ENROLL
Finger
Swipe the finger min.
6 times
x 6
PRESS the
PIN Code
1 to 8 digits
Press “A”
Exit
Note: The Fingerprint can be deleted by keypad, only if it is enrolled with keypad.
Press
0A
to exit the Menu
Example 1: Add user finger to Relay1 - Press 1234 + A + 1 + 1 + 1 + 01 + A + Enroll finger 6 times. 0A to exit.
Example 2: Add user PIN 147 to Relay2 - Press 1234 + A + 1 + 2 + 2 + 02 + A + 147 + A. 0A to exit.
www.xprgroup.com
13
13. INSTALLER PROGRAMMING BY KEYPAD
ENTER
INSTALLER
CODE
default: 5678+A
Note: Entering this menu is done by installer PIN Code. You can not enter with Installer Finger.
Set Relay 1
TIME
(on board)
1
Press 0A to exit the Menu
MENU
Set Relay 2
TIME
(remote)
2
Buzzer
ON/OFF
3
Press
01 to 30 for time in seconds or
00 for toggle
(ON/OFF) Mode
Press
01 to 30 for time in seconds or
00 for toggle
(ON/OFF) Mode
Backlight
ON/OFF
4
Press “A” Press “A” Press “A” Press “A”
Press
0A
to exit the Menu
Example: Change relay1 time to 2 seconds - 5678 + A + 1 + 02 + A.
www.xprgroup.com
14
www.xprgroup.com
15
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS2 directive EN50581:2012 www.xprgroup.com
16

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Standalone biometric reader
- Stores up to 100 fingerprints
- Can be paired with remote relay unit
- Can be used with optional card reader and keypad
- Can control one or two relays
- Tamper switch for extra security
- Advanced capacitive sensing technology