Exchange of pressure foot 3-2-11 Exchange / Adjustment of

In order to conduct adjustment and exchange safely and surely,
please be sure to abide by what is mentioned in this manual to prevent trouble.
When you conduct adjustment and exchange using this manual, please be sure to use together with instruction
with it in hand.
# Please conduct in accordance with work process in this manual.
# In case there are no specific instructions or explanations in work process.
please be sure to unplug cord from receptacle.
# When you exchange parts, please be sure to use genuine parts designated by us.
# Please never remodel the embroidery machine.
Index
page
Exchange of pressure foot
3-2-11 Exchange / Adjustment of pressure foot
45,46
3-1-2
21
Fixing of needle.
3-3-6 Adjustment of needle height.
58,59
Exchange and Adjustment of pressure foot
3-2-11
4. Remove needle, needle holder and cushion.
1. Remove thread guide plate B ass’y. (Fixing screw 2 pcs)
<Caution> Please care when remove Needle holder, pop
down Pressure foot.
2. Remove front panel. (Fixing screw 2 pcs)
5. Remove pressure foot. (Fixing screw 1 pcs)
3. Remove lower front panel. (Fixing screw 2 pcs)
6. Install good parts.
45
Exchange and Adjustment of pressure foot
3-2-11
11. Insert [Gauge I.2mm] between needle plate and pressure
7. Please set needle and needle clamp.
For set needle, please reference [3-1-2 Fixing of
foot.
needle].
1.2 mm is standard, But please adjust depends by thick of
material.
8. Adjust needle height.
Please refer to [3-3-6 Adjustment of needle height].
9. Bring needle bar down.
12. Tighten fixing screw for pressure foot.
(Fixing screw 1 pcs)
At this moment, no gap between gauge and pressure foot
or needle plate.
10. Turn upper shaft and set dial disc to [ 0 degree ].
13. Return lower front panel, front panel and thread guide
plate B to previous places to finish.
46
Fixing of needle
3-1-2
1. In order of (1)-(4), please remove and fix needle.
(1) Loosen screw holding needle.
(2) Remove needle.
(3) Insert needle till it goes to the end.
(4) Tighten screw holding needle.
Fix needle so that needle groove faces front.
Needle holder
Needle
Front
3-3-6
Adjustment of needle height
1. At this time, lower front panel. (Fixing screw 2 pcs)
5. Turn upper shaft to set dial disc to [ L + 5 degrees].
2. Remove bobbin case.
6. Loosen screw on needle bar boss.
3. Bring needle bar down.
6. Put needle height gauge in rotary hook.
58
3-3-6
Adjustment of needle height
7. Adjust the needle bar height up and down till the needle tip
9. Tighten the screw of needle bar boss.
touches to the gauge slightly.
10. Produce Needle height gauge from hook.
9. Set direction of needle stop as illustrated below.
11. Back main shaft to [270 degree] position.
12. Set Lower front panel and bobbin case then end
of process.
About 30 degrees