installation instructions for electronic sensor activated lavatory faucets

Code No. 0816490
Rev. 1 (08/06)
INSTALLATION INSTRUCTIONS FOR ELECTRONIC
SENSOR ACTIVATED LAVATORY FAUCETS
PRIOR TO INSTALLATION
Prior to installing the Sloan Optima EAF-275/
EAF-250/EAF-200 Series faucets, install the items
listed below. Also, refer to rough-in illustrations.
• Lavatory/sink
• Drain line
• Hot and cold water supply lines or pre-tempered
water supply line
IMPORTANT:
Battery Powered
Sensor Activated
Lavatory Faucets
• ALL PLUMBING SHOULD BE INSTALLED IN
ACCORDANCE WITH APPLICABLE CODES AND
REGULATIONS.
• FLUSH ALL WATER LINES PRIOR TO MAKING
CONNECTIONS.
• KEEP THREAD SEALANT OUT OF YOUR
WATERWAY TO PREVENT COMPONENT PART
DAMAGE! DO NOT USE ANY SEALANT ON
COMPRESSION FITTINGS.
EAF-200 Series
Trim Plates
Transformer Powered
Sensor Activated
Lavatory Faucets
When the EAF faucet is installed on a sink that has
three (3) hole punchings, a Trim Plate should be
used. Trim Plates must be specified and ordered
separately.
ETF-312-A Trim Plate for 4” (102 mm) Centerset
Sink
ETF-510-A Trim Plate for 8” (203 mm) Centerset
Sink
EAF-250 Series
EAF-275 Series
Solar Powered
with Battery Backup
Sensor Activated
Lavatory Faucets
(Models shown with ISM Integral Spout Mixer)
LIMITED WARRANTY
Sloan Valve Company warrants its Optima EAF-275, EAF-250 and EAF-200 Series Electronic Hand Washing Faucets to be made
of first class materials, free from defects of material or workmanship under normal use and to perform the service for which they
are intended in a thoroughly reliable and efficient manner when properly installed and serviced, for a period of three years from
date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to
be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this
warranty. No claims will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or
organizations who purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This
warranty does not cover the life of the battery.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE
COMPANY RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
TOOLS REQUIRED FOR INSTALLATION
• 13 mm open end wrench or nut driver for faucet
retainer nut
• 3/4” open end wrench for female end of flex hose
FAUCET ROUGH-IN
SINGLE WATER SUPPLY
HOT AND COLD WATER SUPPLY
SPOUT
SPOUT
1-3/16” (30 mm) MIN.
DIA. HOLE REQUIRED
O-RING
4-11/32”
(110 mm)
MIXING LEVER
(Can Be Set and Removed)
24º
1-3/16” (30 mm) MIN.
DIA. HOLE REQUIRED
O-RING
2-3/8
(60 mm)
GASKET
GASKET
1-1/2” (38 mm)
MAX. DECK
THICKNESS
RETAINER
1-1/2” (38 mm)
MAX. DECK
THICKNESS
RETAINER
NUT
NUT
13” (330 mm)
LONG FLEX HOSE
5-11/32”
(136 mm)
TEMPERED
SUPPLY
HOT
SUPPLY
13” (330 mm)
LONG FLEX HOSE
COLD
SUPPLY
2-1/16”
(52 mm)
If a connection to separate hot and cold water supplies
is desired, then a Bak-Chek® tee fitting (not supplied)
must be used prior to connecting to the faucet.
2-9/16
(65 mm)
1
Install Faucet.
Slide Gasket over Flex Hose(s) and
secure with Faucet Retainer and
Nut.
2
A Remove Nut, Faucet
Retainer and Gasket
Do Not remove the
O-ring from base of
faucet.
O-RING —
DO NOT REMOVE
FAUCET
GASKET
O-RING
FAUCET RETAINER
B Install Faucet with O-ring
NUT
GASKET
FAUCET
into the center hole in
deck or lavatory —
1-3/16" (30 mm) min. hole
required.
Note: If installing the
faucet on a three (3) hole
sink, a Trim Plate should
be installed at this time.
O-RING
FAUCET RETAINER
NUT
FLEX HOSE
CENTER HOLE IN
DECK OR LAVATORY
3
Install Strainer and Flex Hose onto
Supply Stop.
4
Open Supply Stops and Remove
Sensor Label. Plug-in the
Transformer (Model EAF-200 only).
IMPORTANT: Flush dirt, debris, and sediment from Supply
Line(s) before Connecting Flex Hoses.
A Install Strainer and
FLEX HOSE
Flex Hose onto
Supply Stop.
A Open Supply Stop(s).
B Remove Label from
Sensor Window.
C For EAF-200 Models,
Plug Transformer into
receptacle.
STRAINER
B Tighten the Flex Hose
(with Strainer in place)
securely to the Supply.
TRANSFORMER
SUPPLY LINE/STOP
SENSOR
LABEL
2
5
Activate Faucet.
6
Set and Fix Temperature.
A Adjust lever to set temperature.
A Activate Faucet, then immediately step away.
Faucet will run for four (4) seconds and the range
will automatically adjust to its environment. Wait
ten (10) seconds after water shuts off before
using Faucet.
B To fix temperature, set lever to the desired
position, then remove lever and plug hole with
Cap.
B Activate Faucet and check for leaks.
7
Battery Replacement
D Wait three (3) minutes
before inserting new
battery.
NOTE: Replace Battery when red LED indicator flashes each time
faucet is in use or when faucet stops functioning.
3 min
E Insert a new 6 Volt Type 2CR5
Lithium Battery. The red LED
will flash for one (1) minute.
Reinstall Battery Cover.
If LED doesn't flash or if it just
lights up, remove the Battery.
Wait three (3) minutes, then
reinsert the Battery.
If water flows
continuously after
inserting the new
Battery and opening the
Supply Stops, remove the
Battery. Wait three (3) minutes,
then reinsert the Battery.
A Close Supply
Stop(s).
C Move Battery Retainer
B Loosen Screw
with hex wrench
and remove Cap.
tab away from Battery.
Remove old Battery.
Dispose of properly.
F Open Supply Stop(s).
3
PARTS LIST
-Click SETTINGS
Function
Press Button
LED Signal
Continuous Run — 2 minute
default setting (adjustable from
1 - 20 minutes)
1 time for 2 seconds
5 short flashes
2A
2B
7A
3A
3B
3C
will reset automatically
reset: 1 time orafter
2 minutes
Temporary Off
2 times (double click)
5 short flashes followed by
periodic flashing
will reset automatically
reset: 1 time orafter
2 minutes
Permanent Off
Consult Factory
reset:
Auto Set Range Adjustment
8
7B
1
Periodic flashing and then 2
long flashes
4
5
1 time
2 times (double click) and then
1 time for 5 seconds
5 short flashes followed by 4
short flashes
11
TROUBLESHOOTING GUIDE
1. Problem:
Cause:
Solution:
Cause:
Solution:
Faucet does not function.
Adhesive packaging label affixed over sensor eye.
Remove adhesive label from sensor eye.
"Permanent Off" activated.
Press button on faucet throat one time.
9
12
2. Problem: Faucet delivers water in an uncontrolled manner.
Cause:
Faucet is defective.
Solution: Contact the Sloan Valve Company Installation Engineering
Department (see below).
3. Problem: Faucet does not deliver any water when Sensor is
activated.
Indicator: Solenoid valve produces an audible “CLICK.”
Cause:
Water supply stop(s) closed.
Solution: Open water supply stop(s).
Cause:
Water supply stop strainer(s) clogged.
Solution: Remove, clean, and reinstall water supply stop
strainer(s).Replace strainer(s) if required.
Indicator: Solenoid valve DOES NOT produce an audible “CLICK.”
Cause:
Battery low.
Solution: Replace battery (refer to Battery Replacement, Step 7).
4. Problem: Faucet delivers only a slow flow or dribble when Sensor
is activated.
Cause:
Water supply stop(s) are partially closed.
Solution: Completely open water supply stop(s).
Cause:
Water supply stop strainer(s) clogged.
Solution: Remove, clean, and reinstall water supply stop
strainer(s).Replace strainer(s) if required.
Cause:
Aerator is clogged.
Solution: Remove, clean, and reinstall Aerator. Replace Aerator if
required.
Cause:
Faucet is defective.
Solution: Contact the Sloan Valve Company Installation Engineering
Department (see below).
5. Problem: Faucet does not stop delivering water or continues to
drip after user is no longer detected.
Cause:
Valve is defective.
Solution: Contact the Sloan Valve Company Installation Engineering
Department (see below).
6. Problem: LED indicator blinks when faucet is in use.
Cause:
Battery low.
Solution: Replace battery (refer to Battery Replacement, Step 7).
7. Problem: The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines.
Cause:
Supply Stops are not adjusted properly.
Solution: Adjust Supply Stops.
Cause:
For models with integral mixing valve — Mixing valve is set
improperly for the water temperature desired.
Solution: Rotate mixing valve handle clockwise to decrease water
temperature or counterclockwise to increase water temperature.
When assistance is required, please contact Sloan Valve Company Installation
Engineering Department at:
1-888-SLOAN-14: (1-888-756-2614) OR 1-847-233-2016
10
6
Item Part
No. No.
Description
1
2A
2B
3A
3B
3C
4
5
6
7A
7B
8
9
10
11
12
Faucet Sensor Assembly
Cap and Solar Cell Assembly (EAF-275 only)
Cap (EAF-250 and EAF-200 only)
0.5 gpm (1.9 Lpm) VR Aerator Spray Head
2.2 gpm (8.3 Lpm) Aerator Spray Head
2.2 gpm (8.3 Lpm) Laminar Flow Spray Head
Battery Replacement Kit
Faucet Mounting Kit
Strainer (Filter)
Mixer Handle Assembly and Cartridge
Handle Repair Kit
Handle Cap
13” (330 mm) Flexible Supply Hose
Trim Plate for 4” Centerset Sink
Trim Plate for 8” Centerset Sink
Transformer
EAF-14-A
EAF-1006
EAF-27
EAF-15
EAF-10
EAF-13
EAF-1003
EAF-1
EAF-9
EAF-1004
EAF-1005
EAF-1007
EAF-1008
ETF-312-A
ETF-510-A
EAF-11
OPERATION
As the user’s hands enter the beam’s
effective range, the beam is reflected back
into the sensor receiver and activates the
solenoid valve allowing water to flow from
the faucet. Water will flow until the hands
are removed or until the faucet reaches its
automatic time out limit setting.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use abrasive or chemical cleaners (including chlorine
bleach) to clean Faucets that may dull the luster and attack the
chrome or special decorative finishes. Use ONLY mild soap
and water, then wipe dry with clean cloth or towel.
While cleaning the bathroom tile, protect the Faucet from any
splattering of cleaner. Acids and cleaning fluids will discolor
or remove chrome plating.
The information contained in this document is subject to change without notice.
SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380
www.sloanvalve.com
Copyright © 2006 SLOAN VALVE COMPANY
Printed 08-06
Download PDF