Spec Sheet - LSP Products

WASHING MACHINE
PULL STOP BOX™
Specification Sheet
DIMENSIONS
Escutcheon
3-1/2”
SPECIFICATION
Front View
Furnish and install the Washing Machine Pull Stop Box™
outlet box as manufactured by LSP Products Group.
DESIGN FEATURES
 Patented design moves the angle-stop for washing
machine water supply into the wall
 Allows angle stops to be installed during the rough-in
phase and be pressure tested for reduced liability and
labor
 Easy to install vertically, upside down and, horizontally
 Eliminates the need for a copper stub out
 Unique push-pull handle opens and closes the valve
 Integrated, replaceable valve has a reliable triple Oring design inlet seal
 5-year, limited warranty
 Available deep faceplate accepts up to two sheets of
5/8” drywall
 Ball valve design with Teflon seats
COMPLIANCES/LISTINGS
 3/4” GHT outlet connection
 IAPMO listed to ASME A112.18.1/CSA B125.1, File 4577
 IAPMO listed to PS 54, File 0901
CAUTION
 ICC-ES Listed to PMG-1154
 Keep away from solvents/cements/primers
 Keep out of the sun
OPERATING SPECIFICATION
 Temperature: 40-180ºF
 Pressure: 125 PSI max.
Product Submittal
Job Name:
Date:
Part Number
3689 Arrowhead Drive, Carson City, NV 89706
Phone: (800) 854-3215 | Fax: (800) 243-1777
E-mail: sales@lspproducts.com | Website: www.lspproducts.com
Content matter is subject to change at any time. It is the user’s responsibility to ensure the
most updated revisions are obtained.
Architect:
Contractor:
Quantity
WASHING MACHINE
PULL STOP BOX™
Specification Sheet
Part Number
Inlet Type
ROUGH-IN KIT - includes box, valve, and protective cover
OBFPS-121-RK
½” Sweat Lead Free
OBFPS-122-RK
½” CPVC Lead Free
OBFPS-123-RK
½” PEX (Vanguard and Zurn) Lead
Free
OBFPS-124-RK
½” Wirsbo/Uponor PEX Lead Free
TRIM KIT - includes knob and escutcheon
OBPS-400-W*
White - Paintable - Regular Depth
1/2” to 1” Depth, Includes two screws
OBPS-400D-W*
White - Paintable - Deep Depth 1” to
1.72” Depth, Includes two screws and red
ACCESSORIES/REPLACEMENT PARTS
OBD-100
Washing Machine Drain box with optional
condensate.
P-06923
Escutcheon Extension - Can be used with
any trim kit to cover any excessively large
holes in the drywall up to 4.5” diameter
hole. MUST BE USED WITH AN EXISTING TRIM KIT.
P-06930
Duel Escutcheon Extension - For side by
side installations. Can be used with any 2
trim kits to cover any excessively large
holes in the drywall up to 4.5” diameter
hole. MUST BE USED WITH EXISTING
TRIM KITs.
P-06881
3/4” GHT, 1/4 Turn Replacement
Valve
OBPS-500D-W
Escutcheon depth Extension Kit, .8”
additional depth for cabinet backs and/
or for more than two layers of drywall
P-06926
Extension rod for PSB handle for deep
installations
and red clip
clip
*Great for ice maker, dishwasher and washing machine Pull Stop
Box™.
AUXILIARY FIXTURING
MATERIAL SPECIFICATIONS
Part
Material
Valve Body, Stem
Brass
Valve Handle
Cast Aluminum
Ball
Chrome Plated Brass
O-rings
High Temperature Rubber
Box
High Impact ABS
PEX Inlet Connection
Engineered Polymer PPSU
CPVC Inlet Connection
Fitting Grade CPVC
Copper Inlet Connection
ASTM B88 Copper Tube
P-1078-18
18” Straight HYCO bar
P-1078-26
26” Straight HYCO bar
P-1090
Boss Bar™ - 10” to 18” adjustable
sliding bracket
P-1093
Boss Bar™ - 13” to 24” adjustable
sliding bracket
Product Submittal
Job Name:
Date:
Part Number
3689 Arrowhead Drive, Carson City, NV 89706
Phone: (800) 854-3215 | Fax: (800) 243-1777
E-mail: sales@lspproducts.com | Website: www.lspproducts.com
Content matter is subject to change at any time. It is the user’s responsibility to ensure the
most updated revisions are obtained.
Architect:
Contractor:
Quantity
WASHING MACHINE
PULL STOP BOX™
Specification Sheet
ROUGH-IN INSTALLATION INSTRUCTIONS
1. Identify the desired outlet location.
TRIM INSTALLATION INSTRUCTIONS
1. Pull off the protective cover.
2. Attach the supply line to the valve inlet via pipe
manufactures recommended practice. (i.e. sweat for
copper, solvent cement for CPVC, crimp rings for
PEX)
2. Line up the threaded metal arm to fit through the square
hole in the escutcheon and push the escutcheon into the
outlet box until it is flush with the wall while making sure to
feed the threaded metal arm through the square hole.
3. Fasten the Washing Machine Pull Stop Box™ using
two screws or two nails into a stud. (Do not over
tighten screws or over drive nails). Supply line pipe
clamps need to be installed a minimum of 6 inches
above/below Pull Stop Box™ inlet connection
3. Screw escutcheon in using the two supplied screws.
4. The Washing Machine Pull Stop Box™ is shipped in
the “off” position. Once the box is securely attached
to the wall and the supply line is properly attached,
no further work is necessary during the rough-in
phase. The included protective cover provides
significantly better protection of the valve/valve
threads during the drywalling/construction
processes.
4. Thread the knob onto the threaded metal arm until there is
interference with the escutcheon, but a minimum of four
complete turns.
5. Snap “U” shaped part of the red clip onto the knob to prevent the valve from being accidently turned on.
6. When it’s time to install the supply line, simply tighten it
onto the valve outlet. There is no need to remove the escutcheon.
7. When water supply is desired, pull off the red clip, push
the knob towards the wall to turn the valve on, and then
snap the “C” shaped part of the red clip onto the end of the
handle for storage.
8. To stop the flow of water, pull the knob out.
VALVE REPLACEMENT INSTRUCTIONS
1. Turn off water supply to building. Then, pull knob to “off”
position.
2. Unscrew knob and screws. Then, pull out the escutcheon.
3. Remove the screw and valve block. Then, remove current
valve and replace with a new one.
4. Secure the valve block back into place with the screw.
5. Follow steps 3-8 under Trim Installation Instructions.
OPERATING SPECIFICATION
 Temperature: 40-180ºF
 Pressure: 125 PSI max.
Product Submittal
Job Name:
Date:
Part Number
3689 Arrowhead Drive, Carson City, NV 89706
Phone: (800) 854-3215 | Fax: (800) 243-1777
E-mail: sales@lspproducts.com | Website: www.lspproducts.com
Content matter is subject to change at any time. It is the user’s responsibility to ensure the
most updated revisions are obtained.
SP/SH (04-14) Rev 3
Architect:
Contractor:
Quantity