BURGLAR ALARM CONTROL UNIT
INSTALLATION MANUAL
Address: Room1121 Linqiao Piazza, Ningbo City,315010, China
Tel:+86(574) 27861829 27861849 27861830 Fax:+86(574)87264906
E-mail: sales@dswbrand.com
HTTP://WWW.DSW brand.COM
NINGBO DSW INTERNATIONAL CO., LTD
INSTALLATION INFORMATION
Appendix2 Zone type setting figure
Wireless zone
User
User address
Zone number
Installer
1
Installation company
2
Installation date
3
Tel of installation company
Installation position
Type
Bypass or not
Type
Bypass or not
4
Fax of installation company
5
Alarm center
6
Address of alarm center
7
Tel of alarm center
8
Tel of the control panel
9
10
CONTAINER LOADING LIST
11
The components of the product are packed in a box as followed.
Open the box and check it carefully. If finding deficiency, please
fetch the provider in time.
12
14
15
NO.
Name
Amount
1
Control panel
1
2
Remote Controller
2
3
Wireless Passive Infrared Detector
1
4
Wireless Magnetic Switch
1
Zone number
5
Power adapter
1
21
6
Installation manual
1
22
7
Attachment bag
1
23
Note: There are four line resistors(2.2k)four screws and expand
tube.
16
Wired zone
Installation position
24
-35-
No.
Setting item
Keypad operation
Parameter / Select
Default
imed auto-arm
17 T
time setting
35 X Y #
X=1~3(NO.X auto-arm time)
Y=88 88
Y= hour minute(4 digits)
auto-disarm
18 Timed
time setting
36 X Y #
X=1~3(NO. X auto-disarm
t i m e ) Y = h o u r m i n u t e ( 4 Y=88 88
digits)
19 Zone types setting
40 X Y #
X=01~16(16 Wireless zones) Refer to
X=21~24(4 Wired zones)
system
Type code Y=1~8
setting
wireless zone
20 Enroll
detector
61
X
#
X=01~16(NO. X wireless
zone detector)
62
X
#
X=01~16(NO. X wireless
zone detector )
63
X
#
X=1~5(NO. X wireless
remote controller)
23 controller canceling
64
X
#
X=1~5(NO. X wireless
remote controller
24 Zone bypass
65
X
#
X=01~16(16 wireless zones)
X=21~24 (4 wired zones)
X=17 ( panic zone)
X=30(conrtol panel antitamper zone)
one bypass
25 Z
canceling
66
X
#
Ditto
26 Sound recording
70
0
#
Record user address
27 Record playing
71
X
#
X=1~8 play alarm type,
X=9 play user address
1~40 event
28 NO.
records reading
80
X
#
X=01~40, read 1~40 records
#
X=1 inquire U1 software
version number
X=2 inquire U201 software
version number
X=3 inquire U402 software
version number
Wireless
zone
21 detector canceling
Enroll wireless
22 remote controller
Wireless remote
No bypass
except
w i r e d
zones
CONTENT
1. General
2. Main functions and features
3. Term definition
4. Notice before using
5. System installation
6. Operation explanations
6.1 Control panel composition
6.2 Power supply connection
6.3 System initialization finished
6.4 Alarm
6.5 Alarm type
7. Zone type and zone number
7.1 Zone type
7.2 Zone number
7.3 Zone type displaying
8. Function key operation
8.1 Arm-away
8.2 Arm-stay
8.3 Disarm
8.4 Panic
9. Program the system
9.1 Password input
9.2 Operation skills
9.3 System setting
9.3.1 Alarm telephone number setting/canceling
9.3. 2 User address code setting
9.3.3 User password modification
9.3.4 Operation password setting/canceling
9.3.5 Ringing attempts adjustment
9.3.6 Bell ON/OFF setting
9.3.7 Timed auto-arm/disarm option
1
1
2
3
3
7
7
8
8
8
9
10
10
10
10
10
11
11
12
13
13
13
14
15
15
16
16
16
17
17
17
18
18
18
version
29 Software
number inquiring
88
30 All zones bypassed
910
X
#
zones bypassed
31 All
canceling
920
X
#
wireless zone
32 All
detectors canceling
930
X
#
wireless remote
33 All
controllers canceling
940
X
#
o n e t y p e
34 Z
initialization
950
X
#
9.3.8 Telephone line checking ON/OFF option
9.3.9 Protocol option
9.3.10 Relay output type setting
ystem default
35 S
restoring
960
X
#
9.3.11 Bell /Buzzer chirp time setting...........................................18
9.3.12 Exit delay time adjustment
19
X
-34-
D
6. Dimension: 250 150
45mm
45mm
19
20
20
20
20
21
21
22
23
23
23
23
24
24
25
25
26
27
27
27
27
27
27
27
28
28
28
29
29
29
30
31
31
32
33
35
150mm
9.3.13 Entry delay time adjustment
9.3.14 Year setting
9.3.15 Date setting
9.3.16 Hour and minute setting
9.3.17 Timed auto-arm time setting
9.3.18 Timed auto-disarm time setting
9.3.19 Zone type setting
9.3.20 Enroll wireless zone detector
9.3.21 Wireless zone detector canceling
9.3.22 Enroll wireless remote controller
9.3.23 Wireless remote controller canceling
9.3.24 Zone bypass
9.3.25 Zone bypass canceling
9.3.26 Sound recording
9.3.27 Record playing
9.3.28 Event record reading
9.3.29 Software version number inquiring
9.3.30 All zones bypassed
9.3.31 All zones bypassed canceling
9.3.32 All wireless zone detectors canceling
9.3.33 All wireless remote controllers canceling
9.3.34 Zone type initialization
9.3.35 System default restoring
10 .Remote telephone operation
10.1 Telephone disarm
10.2 Telephone arm-away
10.3 Telephone arm-stay
10.4 Telephone field monitor
10.5 Hearing present alarm type.
10.6 Hang-up/stop alarm dialing
11. Control Panel Communication Code
12. Limitations of the system
13. Troubles shooting
14. Technical parameter
Appendix 1 Parameter setting
Appendix 2 Zone type setting figure
250mm
Appendix1 Parameter setting
No.
Setting item
Keypad operation
Parameter / Select
Default
attempts
5 Ringing
adjustment
23 X #
6 Bell ON/OFF setting
auto-arm /
7 Timed
auto-disarm option.
24 X #
No.X(X=1~6) alarm
telephone number Y=1~15
digits telephone number
X is the 4 digits user address
code
X is the 4 digits new user
password
X=1~5 (NO. Xoperation
password) Y is the 4 digits
new operation password
X=1~9times(X=0 indicating
no telephone remote control
and no automatically
receiving the telephone)
X=1: ON, X=0: OFF
25 X #
X=1: Valid,X=0: Invalid
X=0
8
Telephone line
checking option
26 X #
X=1: ON, X=0: OFF
X=1
9
Protocol option
27 X #
output type
10 Relay
setting
28 X #
31 X #
X=0
X=0:ContactID, X=1:4+1
X=1:Alarm output
X=2:Fire alarm output
X=2
X=3:Arm output
X=00 30 the delay time are X=10,
0~30minutes
10minutes
X=00 30 the delay time are X=10,
0~300seconds
100seconds
X=00 30 the delay time are X=04,
0~300seconds
40seconds
14 Year setting
32 X #
X=year (2digits)
X=00
15 Date setting
33 X #
X=month date(4 digits)
X=01 01
Hour and minute
16 setting
34 X #
X= hour minute(4 digits)
X=00 00
1
2
3
4
Alarm telephone
number setting
User address code
setting
User password
modification
Operation password
modification
Bell and buzzer chip
11 time adjustment
Exit delay time
12 adjustment
Entry delay time
13 adjustment.
11
X Y #
20
X
#
21 X #
22 X #
29 X #
30 X #
-33-
Null
1234
1234
Null
X=6
X=1
Types of fault
Potential reasons
Solutions
Cancel bypass of the zone.
The zone is bypassed
The system has no
feedback when zone is When disarm, zone 1,2,3 do
not alarm; arm-stay zone 2 Operate normally
touched.
does not alarm.
Timed arm/disarm is not set Set timed arm/disarm in
in valid statue
valid status
T i m e d a u t o - a r m / a u t o - Arm/disarm with the same time Reset the arm/disarm time
disarm invalidation
Can't disarm when emergency
happens or the system is in Refer to Timed autoarm/auto-disarm
enter-delay status
Different wireless zones use Cancel this wireless zone
Wireless zone misinformation the same code learn
change the code learn
and try again
14. Technical parameter
14.1 General data
1. Requirement of wired zone: connect to 2.2K resistance
2. Control device:
Wireless remote controller
Keypad
Local or remote telephone system
3. Wireless frequency: 315MHz/ 433MHz/868 MHz(optional)
4. Received range of the detector:
90m (in open space)
5. Effective range of the remote controller:
50m (in open space)
6. Length of recording: 4 seconds
7. Dialing mode of alarm: DTMF
8. Relay output parameter:
Contact capacity 10VA
Contact biggest voltage 100VDC
Contact biggest current 0.5A
14.2 Other data
1. Power adapter working voltage: 100V
240V AC
2. Operating voltage of the control panel: 12VDC
3. Static operating current:
4. Bell output current:
130mA
1. General
This is a new kind of intelligent security product .It transmits alarm
information via telephone communication network and is remotely
controlled to deal with emergencies in time, ensuring user's personal and
property safety. This product has complete functions, flexible
configuration; strong destroy protection and convenient operations,
being suitable for residences, stores, factories, warehouses, banks,
schools and hospitals, etc.
2. Main functions and features
Connect 16 programmable wireless zones and 4 programmable wired
zones, compatible with wired/wireless detector.
LCD displays in English.
Compatible with communication protocol: ADEMCO 4+1 and Contact
ID, it is capable of alarming in network or in personal telephone alone.
Automatically dial alarm center user cell phone or fixed telephone with
sound alarm while emergencies happen.
Six alarm received telephones: 1 in alarm center and 5 common
telephones.
Seven passwords: 1user password, 1duress password, 5 operation
passwords.
Wireless code learn.
Arm & disarm by 5 wireless remote controllers at most.
Armed or disarmed by Wireless remote controller telephone or keypad.
Several alarm modes: alarm bell and sound alarm.
Three groups timed auto arm/disarm time.
Zone valid/bypass optional, user can set alarm area type as desired.
Restore user password to factory default by hardware and restore the
system factory default by software.
Record 40 latest alarm events.
Malfunction alarm: AC power loss, battery low voltage and telephone
line loss.
Set real-time clock inside.
Auto-recording function, record the address of the alarm and other
information.
Programmable relay output.
Anti-tamper function of the control panel.
Field monitor function
400mA
5. Operating temperature: -10
+55
-32-
-1-
3.Term definition
12. Limitations of the system
Detector: A facility that detects intrusion and abnormal state
automatically via some electric or physical methods
and output switch signals or wireless signals to the
system for disposal, then sends out alarm signals,
such as infrared detector, smoke detector, etc.
Zone: An area within the detection range of one or one ground
detectors.
Bypass: Close one of the zones temporarily, so that it can not
alarm while act in the zone.
Arm-away: The armed status while going out. All the zones without
bypass are in armed status.
Arm-stay: The armed status at night. All the zones are in armed
status except active zones.
Disarm: Cancel the alarm information that has happened. Close
the entry/exit zones, active zones, perimeter zones.
Other zones are still in arm status.
24-hour zone: No matter armed or disarmed, it is in valid detecting
status. It is usually used in fire alarm, duress alarm
and other emergent alarm which can be cancelled
only by password holder.
Alarm center: It is an alarm receiving station, to which the alarm
controller sends out alarm information via telephone
line when emergencies happen. The station will take
corresponding actions after receiving the alarm.
Entry delay: A period for user to enter detection area, activate the
delay zone and disarm before the system alarms.
During the period, user can activate several specified
zones (entry zone) without alarm immediately. While
exceeding the time, the system alarms if not disarmed.
Zones with entry delay are the exit/enter zone and
active zone.
Exit delay: A period for user to leave detecting area once the system
armed. Zones with exit delay will not alarm during this
period. The zones with exit delay are the exit/enter
zone and the active zone.
User address code: 4 digits code used to be distinguished by the alarm center
when the control panel with network alarms.
Duress password: When user is forced to disarm the control panel by burglar,
user inputs duress password, the control panel is
disarmed but sends alarm information to the alarm
center or receiver. The duress password can be used
to disarm but set parameters. The duress password is
the last digit of user password plus 1 without carry
(9+1=0). E.g. while user password is 8889, the duress
password is 8880; while user password is 9999, the
duress password is 9990.
Although it is an advanced design security system, it does not offer guaranteed
protection against burglary, fire, or other losses. Any alarm system, whether
commercial or residential, is subject to compromise or failure-to-warn for a
variety of reasons. These include:
-2-
1. Intruders may gain access through unprotected openings or have
technical sophistication to invalidate the system.
2. Most detectors can not operate without power, so if AC power loss and
backup power is void, the alarm system can not work.
3. Alarm warning devices such as bells may not alert people if they are
installed in an improper position. If the alarm bell is installed outside, there
are less likely to waken or alert people inside the bedrooms.
4. Telephone line used to transmit alarm signals may be out of service for
any reason, or can not perform communication normally for vicious attack.
5. Unsuitable installation position of detectors. If smoke detector is installed
in an improper position, it is not easy for smoke to enter the detecting area.
Because of doors or walls, it is hard
for the detector to sense fires in other rooms, e.g. the detector in the first
floor can not sense fires in the second floor.
6. Lack of maintenance may lead to the system disabled. Weekly testing is
required to ensure proper operation of the system.
13. Troubleshooting
Types of fault
The system does not dial
to alarm when alarm
happens
Telephone cannot work normally
as the system is connected
into telephone network.
Remote controller can not
operate the system
Potential reasons
Solutions
Do not set correct telephone
number
User telephone is busy
during alarm
Few ringing attempts lead
the system to hang up the
phone automatically
Battery is drained
Set correct telephone
number
Set more than two
telephone numbers
Increase ringing attempts.
Refer to ringing attempts
adjustment
Replace it with a new
battery
Enroll wireless remote controller Enroll wireless remote controller
without programming
with programming
Wireless remote controller is
too far from the controller or
blocked by obstacles.
Wireless zones can not Do not enroll wireless detector
monitor normally.
or the detector is removed
Adjust the distance or angle
between the system and
wireless remote controller
Enroll the detector again
The control panel plug is not Check the connection of
The indicator of power on
inserted in AC socket, or it is the plug or replace the
keypad does not work.
not connected well
socket.
-31-
11. Control Panel Communication Code
Communication between central panel and alarm center have two
formats ADEMCO 4+1 and ADEMCO Contact ID.
ADEMCO 4+1 Table of event
codes NO. Identification
No.
ADEMCO Contact ID OPERATION OF
USER ARM/DISARM Number
DEFINITION
1
Fire alarm, including fire alarm
gas and panic zone
2
Plunder alarm, duress zone
3
Rob alarm, Entry/Exit /Active/
Perimeter/Anti-tamper zone
4
Disarm
5
Arm
6
AC power loss
7
Battery low-voltage
8
Restore default
Operation of using keypad
without password such as armaway disarm and arm-stay
User password to arm/disarm, by
using keypad or remote telephone
01
operation
Corresponding operation password
to arm/disarm by using keypad or
02
remote telephone operation
Wireless remote controller
11 15 arm/disarm
00
21
25 Alarm for disarm/arm operation
98
99
by using telephone number from
2 to 6
Using duress password to disarm,
press 98 to send a disarm information
before duress alarm information
4. Notice before using
Please set 110 as alarm phone number in the control panel with the
police's approval. Read the manual carefully before using.
Connect the AC power supply after ensuring the system is installed
correctly.
Please use backup power to ensure the control panel can work
normally when electric network fails.
Do not disassemble the control panel and detector frequently.
If the user has any problem while using, call our company for help.
5. System installation
5.1 Requirements of engineering installation
Work out a protection scheme based on user protection zone
requirements, then decide the type and rating of the detector.
Confirm the installation position and wiring direction according to the
specific environment. Make sure the position invisible without
affecting its reliability. It is better to wire in concealed way.
The construction scheme and engineering drawings must be filed for
maintenance late.
Timed auto-arm/auto-disarm
5.2 Inner wiring
ADEMCO Contact ID TABLE OF EVENT CODES
No.
100
110
121
131
132
134
137
151
301
302
401
441
455
521
Panic zone alarm
Fire zone alarm
Duress code, Duress zone alarm
Perimeter zone alarm
Active zone alarm
Entry/Exit zone alarm
Control panel anti-tamper alarm. Anti-tamper zone alarm
Gas zone alarm
AC power loss
Battery low-voltage
Arm/Disarm operation
Arm-stay operation
Auto-arm/disarm failing
Bell canceling function
570
Zone bypass operation, zone/user is 99 represent all
zones bypassed or all zones bypass canceling
Open the case of the control panel
DEFINITION
Open outlet door for inserting cables
Outlet slot
Figure 1
Press those two points and
open the back cover
Figure 2
-30-
-3-
Standby battery socket
Standby battery switch
Antenna Standby battery
Anti-tamper switch
Bell output
Wired zone Z1
Wired zone Z2
Wired zone Z3
Wired zone Z4
Password
restore jumper
Power input
Relay output
Grounding
Telephone
line input
Telephone
line output
Keypad line slot
Figure 3 Control panel inside
10.3 Telephone arm-stay
After picking up the telephone, press '# +4digits password(user password,
operation password) + 2 + #' to arm, For example, if user password is
1234, press '#12342#'. When emergencies happen, user has to disarm
first and then arm the system again.
When the control panel dials to alarm, user can press 3 to disarm and
then press 2 to arm after hearing alarm sound.
10.4 Telephone field monitor
After picking up the telephone, press '# + 4digits password(user
password, operation password) + 4 + #' to monitor on the spot. For
example, if password is 1234, press'#12344#'. When the control panel
dials to alarm, user can press 4 to monitor his/her house after hearing
sounds. The control panel will not dial any other numbers.
The field monitor time is about 30 seconds, this status will be over after
hearing the prompt sound 'Di', and user can operate continually in ten
seconds.
10.5 Hearing present alarm type
After wiring close the cover
Figure 4
5.2.1 Power connection
Power Adoption: Input 100V~240VAC 50/60Hz 0.3A, output 12VDC 1A
put the output plug in the power input socket. (Refer to the figure 3)
The control panel with 7.2V/1800mAh NH rechargeable battery as
standby power, put the power cord with plug in the standby battery
socket, turn the standby battery switch KP1 on (Refer to the figure 3) In
working status and the battery is well charged, it can supply the system
with power more than 14 hours, when the battery is low-voltage, it
supply the system with power more than 1.5 hours. If standby battery is
low-voltage and AC power is restored, the system will charge the
standby battery.
When standby battery is low-voltage, power indicator flashes fast,
when AC power is low-voltage, power indicator flashes slow .When AC
power and standby power is in working voltage, power indicator
switched on .When standby or AC power is low- voltage buzzer chirps
1 minute. There is no cue when disarmed.
-4-
After picking up the telephone, press '# + 4digits (user password,
operation password) + 5 + #' to hear present alarm type. For example, if
user password is 1234, press '#12345#'. The control panel will play the
alarm sounds 5 times and pause 5 seconds among them. If no key is
pressed, the system will hang up automatically. If no emergency happens,
user can hear 'Di-' twice.
When the control panel dials to alarm, press 5 to hear alarm type. The
system will play the alarm sound 5 times and pause 5 seconds among
them. If no key is pressed, the system will hang up automatically.
10.6 Hang-up / stop alarm dialing
When the control panel dials to alarm, user presses '0' after hearing
alarm sound, the control panel will hang up automatically and not dial any
other numbers.
When dialing via phone, the system can use operation digit '0' to hang up
automatically
-29-
For example, user password is 1234. To disarm the control panel, user
can press '# 1 2 3 4 3 #' after switching on the system. If the operations is
correct, 'Di' will be heard once. If the operations is incorrect, 'Di' will be
heard twice. If password is wrong, user can input password and operate
digit again without inputting '#' in advance. The control panel will hang up
if password is input incorrectly three times or user does not press any key
in 30 seconds during the operations.
When alarming, the control panel dial user telephone if there is no sound
after receiving the telephone or user unwilling to wait, it is better to press
any key (key '5' recommended), the control panel will send out sound
immediately. First play is the user address record then the alarm type
sound. After playing all of the alarm type sound there will be five second
pause. The system will circulate play the alarm type sound. If user without
press any keys to operate, after playing the sound for five times
the system will hang up automatically. User can operate the control panel
by the key of telephone without input password and '#'. Input the
operation digits directly. The prompt voice is like the above. If user press
the operation digits 0 1 2 3 4 but not '5'', after this command is
operated, the control panel will not dial any other telephones.
Note: Do not press any keys during sounds 'Di' because at the same time
messages can not be received correctly. User had better not press any
key when the system is in sound alarm status. When dialing the telephone
number of control panel, user can operate continually after inputting
password correctly. Just input operate digit and '#'.
5.2.2 Bell output
The biggest drive capacity of bell terminal (+BELL -) is 400mA /12VDC.
Connect the two power lines of the bell to "BELL+" and "BELL-"
terminals.
When the system is powered up and initialized bell will chirp once,
indicating it works normally .Setting the bell on/off and the chirping
time with software.
5.2.3 Wired zone connection
Each loop is connected to an end-of-line (EOL) resistor. For different
detectors, modes of connection are shown as followed:
When connecting N.C. detector, connection
Zone
N.C. Detector
G
Figure 5 N.C. Detector
When connecting N.O. detector, connection mode:
Zone
10.1 Telephone disarm
After picking up the telephone press '# + 4digits password(user password,
operation password) + 3 + # ' to disarm, for example, if user password is
1234, press '#12343#'. When the control panel dials to alarm, user can
press 3 to disarm after hearing alarm sound.
10.2 Telephone arm-away
After picking up the telephone, press '# +4digits password(user password,
operation password) + 1 + #' to arm, When emergencies happen, user has
to disarm first and then
arm the system again. For example, if user password is 1234, press
'#12343#' and then press '1#' to arm after hearing prompt sounds. When
the control panel dials to alarm, user can press 3 to disarm and then press
1 to arm after hearing alarm sound.
-28-
N.O. Detector
G
Figure 6 N.O. Detector
5.2.4Telephone line connection
Connect telephone line to 'LINE_IN' interface of the control panel
(Refer to the figure 3)
Connect telephone or facsimile machine to 'LINE_OUT' interface of the
controller panel, ensuring no effect on telephone. (Refer to the figure 3)
Under the telephone line loss checking status, the control panel will
alarm when the telephone line loss. "T" flashes once a second in lower
right corner of LCD buzzer chirps for 1 minute. After disarmed buzzer
off and "T" flashes on LCD.
-5-
5.2.5Relay output
9.3.30 All zones bypassed
The biggest load capacity of relay terminal ' '
Contact capacity 10VA
Contact biggest voltage 100VDC
Contact biggest current 0.5A
Relay output type can be set as required including alarm output fire alarm
output and armed output. Please refer to program the system.
Operations: (PROG
Functions: The system can provide a command to cancel all bypassed zones.
5.3 Control panel Installation
9.3.32 All wireless zone detectors canceling
The control panel should be mounted in a location which allows
convenient access to AC power, telephone line.
Control panel aerial can not be blocked by subject.
Please use standby power to ensure the control panel can work
normally when electric network fails.
Fix the control panel to the wall by screws. Interval between screws in
the same row is 140mm and vertical intervals between screws in two
rows are 80mm. Nail 4 screws in the wall and hang the control panel on
the screws. (Refer to the figures below.)
Enter: 910
user password
#)
910
#.
Functions: The system can provide a command to bypass all zones.
9.3.31All zones bypass canceling
Operations: (PROG
Operations: (PROG
user password
user password
#)
#)
Enter: 920
920
930
#.
#.
Functions: After the operations, all wireless detectors are canceled;
wireless zones have no effect on the system.
9.3.33 All wireless remote controllers canceling
Operations: (PROG
user password #) 940
4.0mm
Enter: 940
#.
Functions: After the operations, all wireless remote controllers are
canceled; it can not perform the operations of arm away/stay, disarm and
panic alarm etc.
9.3.34 Zone type initialization
2.5
Enter: 930
Operations: (PROG
user password
Enter: 950
#)
950
#.
Functions: After the operations, all zone types restore to defaults in factory
setting.
9.3.35 System default restoring
Notice: while hanging the control panel:
refer to the figures (depth of screws in the wall)
Figure 7
Operations: (PROG
user password #) 960
Enter: 960
#.
Functions: After the operations, all parameters restore to default in factory
setting .User password, operation password, user address code, telephone
number and date can not be canceled by this operation.
10. Remote telephone operation
Figure 8
-6-
User can dial telephone number of the control panel perform the
operations: arm away/stay, disarm field monitor and hearing alarm types.
Dial telephone number of the control panel for more than ringing attempts
set. The system will answer automatically and announce the user with a
sound 'Di'. Then user presses '# + 4 digits password(user password
operation password) + 1 operation digit + #, the control panel will operate
corresponding commands. 6 operation digits, 1 means arm-away, 2
means arm-stay, 3 means disarm,4 means field monitor ,5 means hearing
current alarm sounds,0 means hang-up / stop dialing to alarm.
-27-
commands successfully, alarm time, alarm type, corresponding zone type
and zone number display on LDC. Press '6' key to turn up '9' key to turn down
for continually inquiring. Flip requirement press '#' then press '80 XX #'
until the last inquiring finished.
For example: Inquire the No.5 event record input password
LCD displays alarm time alarm zone and alarm type.
80
05
6. Operation explanations
6.1 Control panel composition
LCD
Record monitor microphone
#,
Armed indicator
Year-Month-Day Hour: Minute
Power indicator
ZONE 17 Panic
Alarm indicator
Key
Horn
Inquire the No.9 event rccord, press '#' first then input 80
event record is null, LCD displays:
09
#. If the
Program Fail!
9.3.29 Software version number inquiring
Operations: (PROG user password #) 88
Enter: 88 X
#.
Parameters definition: X=1 inquire software version number U1
X=2 inquire software version number U201
X=3 inquire software version number U402
Function: When the system is in power supply status, if these three
software version number of CPU are not identical, LCD displays 'Version
vary' and buzzer beeps, cancel this alarm by disarm command. In this
condition it is better to connect the provider in time. This operation can
inquire the three CPU software versions number. For example: inquire
software version number U1: (PROG user password #) 88 1 #.
The U1 CPU
version V 1.1
Indicate present U1 software version number is V1.1
-26-
Figure 9
1. LCD:
Display real-time clock and arm/disarm status.
Display corresponding information and input digits while setting.
Display corresponding zone number and type while alarming. When
telephone line loss, "T" will flashes in the lower right corner of LCD.
2. Armed indicator: indicator on (in arm-away status)
indicator flashes (in arm-stay status)
indicator off (disarmed)
3. Power indicator: indicator flashes quickly indicate standby power lowvoltage
indicator flashes slowly indicate AC power low-voltage
indicator on indicate standby power and AC power is
in normal working status. While standby power or AC
power low voltage, buzzer chirps one minute. Buzzer
off until disarmed.
4. Alarm indicator: indicator on when zone alarming; indicator flashes
when dialing the alarm center.
5.
Horn: send alarm sound while alarming or play the sound by
programming the system.
6. Record monitor microphone: field monitor or used for recording.
7. Key:
Four function keys: AWAY, STAY, DISARM, and PROG keys. The PROG
key is a compound key andthe other function is for panic.
Digit key, "*" key and "#" key are used in programming and relevant
operations. "*" key is used to cancel the last operation; "#" key is
used to confirm the input; "6" and "9" are used to turn pages while
inquiring records of events or many zones alarm at the same time.
Note: As long as any key is pressed, buzzer sounds "Di" and back light is
on. If no key be pressed for 30 seconds the back light turns off.
-7-
6.2 Power supply connection
9.3.27 Record playing
Check line connection again, ensuring all lines are connected correctly.
Switch on AC power or turn on the standby power; buzzer will beep
twice; back light of the keypad and indicator will be on. Keypad begins to
initialize and then buzzer continuously beeps, LCD displays
Operation: (PROG X
#)
Enter: 71 X
71
x
#
Parameters setting: X=1~8 specified alarm sound, X=9 user address
record playing
X=1: entry/exit zone alarm
X=2: active zone alarm
Initialize...
X=3: perimeter zone alarm
X=4: panic zone alarm
LCD circularly displays the status information, buzzer beeps twice in
every minute. Buzzer chirps once until finished the initialization, LCD
displays the status information. The system begins working .If the system
works normally; it will take two seconds for initialization. If this process
takes more than eight seconds LCD displays 'Communication Error',
buzzer chirps once every second .It is because that the main board is not
connected with the row line of the keypad, please plug the row line again.
6.3 System initialization finished
After initialization the LCD displays:
X=5: fire zone alarm
X=6: gas zone alarm
X=7: anti-tamper zone alarm
X=8: duress zone alarm
X=9: (sound recorded by user.)
Function: User can check sound effect of recording and play alarm type
sound .
For example: (PROG user password #) 719
#
While playing, LCD displays:
Arm-away
Playing...
04 sec
Year-Month-Day Hour: Minute
Indicating the system is in arm-away status, the present time is Year
Month Date Hour Second. May be the system is in arm-stay or disarm
status. The corresponding display is the status when the system is closed
last time.
While the playing record time reduce from four seconds to zero
(user
recording time is four seconds, sound of alarm type is about two seconds)
playing finished. After playing, LCD displays the information about reenter
command status as followed:
Version vary!
Input Command
Year-Month-Day Hour: Minute
If LCD displays 'Version vary!' buzzer sends out alarm voice , indicating
CPU (U1 U201 U402) with different software version number. Cleaning
the alarm voice and the display by the disarm command. In this status
please contact with the manufacture or the supplier. Refer to the
appendix 1 for inquiring software version number.
9.3.28 Event record reading
Operations: (PROG
Enter: 80 XX
user password
#)
80
XX
#.
Parameters definition: XX=01~40 event records.
6.4 Alarm
Functions: The system stores 40 event records, which can be inquired by
user any time. The system records alarm in zones, but no fault alarm for AC
power loss, battery low voltage, telephone line loss, etc.
The control panel alarm can be classifies under two types: zone alarm
and fault alarm.
Note: XX=01~40 is event number in time order. The latest event number is
01, the rest are numbered in this way. When the 40 records are restored, the
latest event records replace the oldest event records. After inputting
-8-
-25-
XX=21~24 (4 wired zones);
XX=30(control panel with anti-tamper function)
Bypass for all wired zones in factory default setting, no bypass for other
zones.
Functions: Close some zone temporarily, then the zone can be activated
freely without alarm.
9.3.25 Zone bypass canceling
Operations: (PROG
user password #)
Enter: 66 XX
66
XX #.
Parameters definition: XX means canceling bypassed zone number.
XX=01~16 (16 wireless zones)
XX=21~24 (4wired zones);
XX=30(control panel with anti-tamper function)
Functions: User can cancel bypass in the zone to restore alarm function of
some bypassed zone.
Operation: (PROG
Enter: 700
user password # )
700
#
While recording LCD displays:
Recording...
04 sec
User had better close to the microphone. The recording time is about four
seconds. After recording, LCD displays the information about reenter the
input command status as followed:
Input Command
User can check sound effect of recording. Operate the recording command,
the horn will play the record.
Function: The control panel can record sound for 4 seconds. User can
record family address and other alarm voice. When alarming, the system
sends the record to receiver via telephone network then sends the alarm
type record.
-24-
Please disarm!
If disarm before the end of enter-delay time there will be no zone alarm
otherwise the system will prompt zone alarm. If the system is in zone
alarm status and connect the zone with enter-delay, the system prompt
zone alarm only but enter-delay.
Zone number
Real time
XX=17('Panic' key on the keypad and remote
controller)
9.3.26 Sound recording
1)Zone alarm
The zone will alarm with the connection of 24- hour zone .If connects the
zone with enter-delay, the buzzer will chirp tightly and LCD displays:
ZONE 17 Panic
Year-Month-Day Hour: Minute T
Zone type
Alarm for telephone
line loss
When alarming LCD displays relevant alarm zone number and zone type,
alarm indicator is switched on, buzzer chirps tightly .If zones alarm at the
same time , LCD circularly displays the alarm zone number and zone type
every two seconds or press '6' key or '9' key to flip the alarm zone information.
2) Fault alarm
The fault alarms including battery in low-voltage AC power loss and
telephone line loss, buzzer chirps 1 minutes, the indicator and LCD
displays corresponding status. The power indicator shows the battery
low-voltage and AC loss power loss. The letter 'T' flashes on the lower
right corner of the LCD every second indicate the telephone line loss.
6.5 Alarm type
Alarm
type
Alarm Phone Alarm
center Alarm indicator
Keypad
buzzer
Bell
Fire zone
Yes
Yes
On
Chirp (time adjustable) Chirp (time adjustable)
Gas zone
Yes
Yes
On
Chirp (time adjustable) Chirp (time adjustable)
Panic zone
Yes
Yes
On
Chirp (time adjustable) Chirp (time adjustable)
Perimeter
zone
Yes
Yes
On
Chirp (time adjustable) Chirp (time adjustable)
Active zone
Yes
Yes
On
Chirp (time adjustable) Chirp (time adjustable)
Entry/Exit
zone
Duress
zone
Anti-tamper
zone
Telephone
line loss
AC power
loss
DC power
low-voltage
Yes
Yes
On
Chirp (time adjustable) Chirp (time adjustable)
Yes
Yes
/
Yes
Yes
On
No
No
/
Chirp for 1 minute
Muted
Muted
Muted
Muted
Muted
Chirp (time adjustable) Chirp (time adjustable)
Yes
No
Flash
Chirp for 1 minute
Yes
No
Flash
Chirp for 1 minute
-9-
7. Zone type and zone number
some remote controller. Changing the code learn to solve the above problem.
If the problem is not because the above reasons, checking the detector and
make sure its carrier frequency is different from the control panel.
7.1 Zone type
Valid or
Valid or
Valid or
Exit Enter Acoustic- Mounted Type
not when not when not when delay delay optic alarm position or number
going out
stay in
disarm
detector
Zone
type
Entry/Exit
zone
Active
zone
Perimeter
zone
Panic
zone
Fire
zone
Gas
zone
Anti-tamper
zone
Duress
zone
Invalid
Valid
Valid
Yes
Yes
Yes
Gate
01
Invalid
Valid
Invalid
Yes
Yes
Yes
Indoor
02
Invalid
Valid
Valid
No
No
Yes
Valid
Valid
Valid
No
No
Yes
Valid
Valid
Valid
No
No
Yes
Valid
Valid
Valid
No
No
Yes
Valid
Valid
Valid
No
No
Yes
Valid
Valid
Valid
No
No
No
Veranda
Window
Panic
Button
Fire
Detector
Gas
Detector
Anti-tamper
Device
Emergency
Button
03
04
Note: After inputting command, user has to activate a wireless detector in 1
minute, other wise the system can't enroll the wireless detector. Moreover,
user had better activate a wireless detector as soon as possible to avoid
influence from wireless clutter wave. During the code learn operation, only
the '*' key is valid, press this key to exit the code learn operation status. The
system is in operation status.
9.3.21 Wireless zone detector canceling
Enter: 62 XX
05
06
07
08
7.2 Zone number
Operations: (PROG
user password
#) 62
XX
#.
Parameters definition: X=01~16, indicating zone number of wireless
detector.
Functions: Reduce wireless detectors as required
For example: Cancel NO.03 detector in wireless zones
Wireless zone: 01~16
Wired zone: 21~24
Panic zone: 17
Duress code: 18
Anti-tamper of the control panel: 30
press: (PROG
user password
#)
62
03
#.
9.3.22 Enroll wireless remote controller
Operations: (PROG
user password
#)
63
Enter: 63 X
X
#.
Parameters definition: X=1~5, number of wireless remote controller.
7.3 Zone type displaying
Functions: The system can enroll 5 wireless remote controllers at most to
do operations of arm away/stay, disarm and panic, add wireless remote
controller as required. After inputting command, press any key of wireless
remote controller towards the control panel until buzzer chips once that
indicate the system enroll the wireless remote controller successful. Refer to
9.3.20.
Zone type
LCD
Type number
Entry/Exit zone
Entry Exit
01
Active zone
Active
02
Perimeter zone
Perimeter
03
Panic zone
Panic
04
Fire zone
Fire
05
Gas zone
Gas
06
Anti-tamper zone
Tamper
07
Parameters definition: X=1~5, number of wireless remote controller.
Duress zone
Duress
08
Functions: After canceling some remote controller they will have no effect
on the system.
8 Function key operation
The operation of arm-away, arm-stay, disarm, and panic can be achieved
by using the function keys on keypad or wireless remote controller. The
system applies wireless remote controller with 4 keys which can achieve
operations of arm-away/stay, disarm and panic alarm. Press key on the
remote controller towards the control panel to perform corresponding
operations.
-10-
9.3.23 Wireless remote controller canceling
Operations: (PROG
user password #) 64
Enter: 64 X
X #.
9.3.24 Zone bypass
Operations: (PROG
Enter: 65 XX
user password #)
65
XX
#.
Parameters definition: XX means zone bypass number.
X=01~16 (16 wireless zones);
XX=17 (Panic key on remote controller and
keypad.)
-23-
The factory default setting is all wireless zones are type 4(panic zone).
Wired zone 21 is type 1(entry/exit zone), Wired zone 22 is type 2(active zone),
Wired zone 23 is type 3(perimeter zone) Wired zone 24 is type 4(panic zone)
Arm-away
Arm-stay
Functions: Set different zone types .It can not modify the zone types of the
zone 17(panic zone), the zone 18 (duress password zone) and the zone
type of the No.30 control panel anti-tamper zone.
Disarm
Panic
For example: Set wired zone 21 as gas zone, wireless zone 3 as fire alarm zone,
press (PROG user password #) 40 21 6 # 40 03 5 #
Note: When the system is in arm- away status, all zones are valid; when the
system is in arm- stay status, active zone is invalid, but other zones are still
valid ; when the system is in disarm status, fire alarm zone, gas zone, panic
zone, anti-tamper zone and duress zone are still valid.
9.3.20 Enroll wireless zone detector
Operations: (PROG
user password #) 61
Figure 10
8.1 Aram-away
1. When the system is in disarm/arm-stay status press 'AWAY' key on the
control panel or remote controller, armed indicator on, buzzer begins to
sound 'Di-Di', the system is in exit-delay status and LCD displays:
Enter: 61 XX
XX
Arming...
#.
Parameters setting: X=01~16, indicating zone number of wireless detector .
Functions: Add wireless detectors as required.
The buzzer will off until exit delay over, LCD displays:
For example: Enroll NO.03 wireless zone detector
press: (PROG
user password
#)
61
03
Arm-away
#.
Learning code...
60 sec
Year-Month-Day Hour: Minute
2. When the system is in zone alarm status, press 'AWAY' key on the
control panel or remote controller,LDC displays:
Can't arm
Please disarm
The code learn operation time is about 60 seconds .During this period,
trigger the zone detector with code learn, buzzer chirps once if the code
inputted is correct, LCD displays:
Input Command
If the system hasn't received the wireless signal at the end of operation time,
it indicate the code learn fail, buzzer chips 5 times, LCD displays:
Program Fail
If Code learn fail after trying and trigger the detector many times, there will
be two reasons: First, the enrolling code learn has been used by some
detector in the system. Second, the enrolling code learn has been used by
-22-
3. In Arm-away status, there is no use to press the 'AWAY' key on the
control panel or press the 'Arm-away' key on the remote controller,
buzzer chips once.
8.2Arm-stay
The arming mode can be applied when user is at home. When all zones
are in armed status without 'Active Zone' is bypassed.
1) If the control panel is in disarmed status, press the 'STAY' key on the
control panel or remote controller, armed indicator flashes, buzzer
chirps once and LCD displays:
Arm-stay
Year-Month-Day Hour: Minute
-11-
2. If the control panel is in 'Arm-away' status and no zone alarms, press
the 'STAY' key on control panel, input password to enter arm-stay
status or press the 'Arm-stay' key on remote controller to enter the armstay status directly ,the buzzer chirps once ,armed indicator flashes.
3. If the control panel is in zone alarm status, press the "STAY" key on the
control panel or remote controller, LCD displays:
Can't arm
Please disarm
X minute (24 hours), default is 8888.
Functions: The system can set 3 groups arm time. If user wants to cancel
some set arm time, set YYYY as 8888.
For example: Set 08:00 and 22:00 as arm time
press: (PROG
#
user password
#)
35
1
0800
#
35
2
2200
Note: Before performing the functions above please set 'Timed autoarm/auto-disarm selection' first. Refer to 9.3.7
4. If the system is in arm- stay status, it is no use to press 'STAY' key on
the control panel or press 'Arm-stay' key on the remote controller,
buzzer chips once
Operations: (PROG
8.3 Disarm
Parameters definition: X means 1~3 groups disarming time. YYYY means
X hour X minute (24 hours), default is 8888.
1. Disarm without reserving the alarm status information press the 'DISARM'
key on the control panel LCD displays:
Functions: The system can set 3 groups disarm time. If user wants to
cancel some set disarming time, set YYYY as 8888.
9.3.18 Timed auto-disarm time setting
user password
#)
Enter: 36 X YYYY
36
X
YYYY
For example: Set 08:00 and 22:00 as disarm time,
Input Password
press: (PROG
#
Input user password or operation password add '0', press '#' confirm.
Armed indicator off, buzzer chirps once, the system is disarmed, LCD
displays
Disarmed
user password
#)
36
1
0800
#
36
9.3.19 Zone type setting
Operations: (PROG
press the function
Input Password
user password
#)
40
Year-Month-Day Hour: Minute
If the system is in zone alarm status, after disarmed, armed indicator off,
buzzer chirps once, LCD displays zone alarm information but the system
is still in disarm status. User can disarm again to clean the alarm
information.
-12-
XX
Y
#.
Parameters definition: XX means wired/wireless zone number.
X=01~16(16 wireless zones)
X=21~24(4 wired zones);
Y=2, active zone;
Y=3, perimeter zone;
Y=4, panic zone;
Disarmed
2200
Enter: 40 XX Y
Y=1, entry/exit zone;
If there is no alarm, input user password or operation password press '#'
confirm. Armed indicator off, buzzer chirps once, the system is disarmed.
LCD displays
2
Note: Before performing the functions above, please set 'Timed autoarm/auto-disarm selection' first, refer to 9.3.7 Auto-arm/disarm time must be
different because they can't be operated at the same time.
Year-Month-Day Hour: Minute
2. Disarm with reserving alarm status information
key 'DISARM' on the control panel, LCD displays:
#
Y=5, fire zone;
Y=6, gas zone;
Y=7, anti-tamper zone;
Y=8, duress zone.
-21-
XX=10(100 seconds)
3. Press the "Disarm" key on the remote controller to disarm with the
same effect of the second method. This operation can not clean the
alarm information. If the system is not in zone alarm status, press the
"Disarm" key on the remote controller, armed indicator off, buzzer
chirps once, the system is disarmed, LCD displays
XX=20(200 seconds)
XX=30(300 seconds)
Disarmed
The factory setting is XX=04(40 seconds)
Year-Month-Day Hour: Minute
Function: The system entry delay time adjustment
Functions: Set year in real-time clock, default value is 2000 and the last two
digits is set by user from 2000 to 2099.
If the system is in zone alarm status, press the 'Disarm' key on the remote
controller after disarmed, the armed indicator off, buzzer chirps once,
LCD displays the zone alarm information but the system is still in disarm
status. Please disarm again by using the first method above.
Note: If the system is not connected with the alarm center, the alarm
indicator off after disarmed. If the system is connected with the alarm
center after disarmed the alarm indicator off after flashing several times.
For example: Set year 2010
8.4 Panic
9.3.14 Year setting
Operations: (PROG
Enter 32 XX
user password
#)
32
XX
#
Parameters definition: XX=00~99, indicating year, default is XX=00.
press (PROG
user password #)
32
10
#.
9.3.15 Date setting
Operations: (PROG
Enter: 33 XXXX
user password
#)
33
XXXX
#
ZONE 17 Panic
Parameters definition: XXXX is for date setting, XXXX means X month X
day, default is XXXX=0101 that is 1st Jan.
9.1 Password input
For example: Set 12th May
user password #)
33
0512
#
9.3.16 Hour and munute setting
Operations : (PROG
user password
Enter: 34 XXXX
#)
34
XXXX
Functions: Set clock in real-time clock.
#)
34
1639
#
9.3.17 Timed auto-arm time setting
Operations: (PROG
user password
#)
Enter: 35 X YYYY
35
Input Password
*****
2. After confirmation, if the password is right, LCD displays
corresponding information .If the password is wrong, buzzer chirps 5
times, LCD displays:
For example: Set 16:39
user password
1. User needs to input password while disarm, RROG, flip arm-away
status and arm-stay status. Operations: press DISARM/PROG /STAY+
user password (or operation password) + # before confirming the
password, LCD displays:
#
Parameters definition: XXXX is for clock setting, XXXX means X hour X
minute (24 hours), default is 0000.
press (PROG
Year-Month-Day Hour: Minute
9. Program the system
Functions: Set date in real-time clock.
press (PROG
Press the 'PROG' key of the control panel or the 'Panic' key of the remote
controller for 2 seconds, the control panel will alarm for panic, alarm
indicator on ,buzzer chirps continually ,LCD displays:
X
YYYY
#
Password Error
Parameters definition: X means 1~3 groups arm time. YYYY means X hour
3. If input wrong password for 5 times continuously, the keypad will lock
operation with password, LDC displays:
-20-
-13-
XX= 02 (2 minutes)
The keyboard
has been locked!
XX =10 (10 minutes)
Note: If the keypad is in locked status, the system will unlock
automatically when zone alarming. The system can unlock automatically
after restarting or waiting half an hour.
XX =20 (20 minutes)
XX =30 (30 minutes)
9.2 Operation skills
The factory setting is XX= 10(10 minutes)
Setting the system in disarmed status otherwise LCD displays:
Can't program
Please disarm!
Function: Buzzer and bell chirp time adjustment
9.3.12 Exit delay time adjustment
Operations: (PROG
User disarms first then input: PROG +user password (not the operation
password) + #, the control panel is in programming status, LCD displays:
Input Command
user password
Enter: 30XX
#)
30
XX #
Parameters definition: XX=00~30, indicating time, unit is 10 seconds,
delay time is among 0~300 seconds.
XX=00(no delay)
XX=01(10 seconds)
XX=02(20 seconds)
Following the prompt of cursor input the commands. If the input digits are
incorrectly, user can press '*'key to delete them then press '#' key to
confirm. If the input command is correct, the control panel chirps twice,
LCD displays:
XX=10(100 seconds)
XX=20(200 seconds)
Input Command
XX=30(300 seconds)
Input the command to set the program, if the input is incorrect, control
panel will chip five times, LCD displays:
Command Error!
The factory setting is XX=10(100 seconds)
Function: The system exit delay time adjustment
9.3.13 Entry delay time adjustment
Operations: (PROG user password #)
Then input commands without password. If the command is correct, the
control panel chirps five times, LCD displays:
Program Fail
-14-
31
XX #
Parameters setting: XX=00~30, indicating time, unit is 10 seconds, delay
time is among 0~300 seconds.
XX=00(no delay)
XX=01(10 seconds)
That indicates the input is correct but the control panel can not carry out
the command, user should input it again.
Enter: 31 XX
XX=02(20 seconds)
-19-
9.3.8 Telephone line checking ON/OFF option
Enter : 26X
Note: If user want to exit program status press '*' to delete digits .When
all digits are deleted, press '*'key to exit. This operation can be realized
by pressing '#' key or the four function keys .In the programming status, if
without pressing any key for 1 minute, the system will exit present status
and return to display clock and arm/disarm status.
Functions: When the control panel is not connected with telephone, use this
command to forbid checking the connection of telephone line. Avoid fault
alarm voice when user turns on the control panel every time.
To program the system, press PROG user password '#' then enter the
programming status. In this status, setting the system with the command
code without password .LCD displays corresponding status or digits.
9.3.9 Protocol option
9.3.1 Alarm telephone number setting/canceling Enter: 11 XY...Y
Operations: (PROG
user password
#)
26
X
#
Operations definition: X=1(ON)
X=0(OFF)
9.3 System setting
The factory setting is X=1(ON)
Operations: (PROG
Enter: 27X
user password #) 27
Parameters definition: X=1
X= 0
(1)Set alarm phone number
X #
Operations: (PROG user password
4+1 Protocol
Functions: The control panel supports 4+1 and Contact ID communication
Protocol. User can choose one of them..
9.3.10 Relay output type setting
user password
Enter: 28 X
#)
28
X
#
Parameters setting: X=1: alarm output
X=2: fire alarm output
X=3: arm output
X=2 is the factory setting (fire alarm output)
Functions: Relay output type is N.O. If alarm output is set, the relay will
close when alarm. If fire alarm output is set, the relay will close only fire zone
alarm. If arm output is set, the relay will close when the system in armed
status.
9.3.11 Bell/Buzzer chirp time setting
Operations: (PROG
user password
#)
Enter:29 XX
29
XX
#
Parameters definition: XX=00~30, indicating time, unit is 1 minute. delay
time is among 0~ 30 minutes
XX=00( 0 minute no alert)
XX= 01 (1 minute)
-18-
11
X Y...Y
#
Bracket means in programming status, it is not necessary to input
Contact ID Protocol
The factory setting is X= 0 and supports Contact ID
Protocol
Operations: (PROG
#)
'PROG
user password
#', just input commands directly.
Parameters setting: X=1~6, indicates 1~6 groups telephone, 1 is alarm
number of the alarm center, 2~6 are personal telephone numbers. Y...Y:
indicates telephone number needed to dial (1~15 digits), telephone number
is null in factory setting.
Functions: The system can be set 6 groups of alarm telephone number. NO.
1 is for the alarm center. User sets the first number, if alarm happens the
system will call alarm center and sent out alarm information using ADEMCO
protocol. The alarm center will take corresponding actions after receiving the
alarm and alarm indicator flashes. If user does not open service of the alarm
center, the system begins to dial number from NO.2 according to alarm
information set. After switching on, play corresponding alarm sound. If user
does not deal with alarm information, the system will continually dial the
telephone number for 30times. (Refer to remote telephone operation).
For example: if user wants to set NO.2&3, operation as followed: PROG
User password # 11 2 telephone number #
11 3 telephone
number #
Note: In duress alarm status, the telephone will not dial the second, the third
and the fourth group of telephones but the alarm center and the fifth, the
sixth group of telephones. Recommended: the fifth, the sixth group of
telephone numbers should not be set like the personal mobile phone number.
(2) Alarm telephone number cancelling
Operations: (PROG
User password
#)
11
X
#
Parameters definition: X=1~6, indicates 1~6 groups telephone. 1 for the
alarm center, 2~6 for personal telephone numbers.
Function: Cancel telephone number set (including telephone number of the
alarm center).
-15-
9.3.2 User address code setting
Operations: (PROG
user password
Enter:20 XXXX
#)
20
XXXX
Operations: (PROG
#
Parameter definition: XXXX = 4 digits user address code. The factory
setting is 1234.
Functions: After setting user address code, when alarm happens, the alarm
center will distinguish which control panel is alarming. Do not set same user
address code in one alarm center system.
9.3.3 User password modification
Operations: (PROG
user password
Enter:21 XXXX
#)
21
XXXX
#
Parameters definition: XXXX is 4 digits new user password. The factory
setting is 1234. User password must be different from the operation
password otherwise LCD displays 'Please select other Password' and
buzzer chirps five times to indicate the failed operation .User can clean
operation password first then set user password to avoid the above
limitations.
Functions: Modify user password which ensure the absolute authority to the
system operation. User must hold password to operate the system. After
setting password, user should ensure its safety and reliability.
Restore password in factory setting: Hardware restores factory setting.
There is a jumper 'CB400' (Refer to figure 3) in control panel .Normally the
jumper is in 'USE' mode, if user forgets password, he/she should turn off
system power, turn jumper to 'DEFAULT' mode, then restart the system to
restore user password in factory setting. After the system is initialized
successfully, user should turn jumper to 'USE' mode, or the system will
restore password in factory setting when initialized next time.
9.3.4 Operation password setting/canceling
Enter:22 X YYYY
user password
#)
22
X
#
Parameter definitions: X=1~5(NO.X operation password)
Functions: Password canceling
9.3.5 Ringing attempts adjustment
Operations: (PROG
user password
Enter:23X
#)
23
X
user password
#)
22
X
YYYY
#
Parameter definitions: X=1~5(NO.X new operation password) YYYY is 4
digits new operation password which is null in factory setting. The new
operation password must be different from the user password and duress
password otherwise LCD displays 'Please select other Password' buzzer
chirps five times to indicate the failed operation.
Functions: User can modify five operation passwords which can only be
used to arm/disarm the system or make the control panel flip arm-away and
arm-stay status but program the system.
-16-
#
Parameters setting: X means ringing attempts. X=1- 9 times (X=0
indicating no telephone remote control and no automatically receiving the
telephone) X = 6 is the factory setting.
Functions: The system is able to operate in remote place. When user in
other place dials phone connected to the control panel, the system will
receive the telephone automatically. User can input password to arm or
disarm.
Note: If telephone and the control panel use the same telephone line, set
ringing attempts as many as possible to avoid clashing. After setting ringing
attempts, the system begins to accept user remote operation.
9.3.6 Bell ON/OFF setting
Operations: (PROG
Enter: 24 X
user password
#)
24
X
#
Parameters definition: X=1(ON)
X=0(OFF)
The factory setting is X=1 (ON).
Functions: User can choose bell alarm or not. Setting the bell, it will be on
when the system alarms; otherwise only buzzer and horn alarm.
9.3.7 Timed auto-arm/disarm option
(1) Operation password setting
Operations: (PROG
(2)Operation password canceling
Operations: (PROG
user password
#)
Enter: 25 X
25
X
#
Parameters definition: X=1: valid (Timed arm/disarm allowed).
X=0: invalid (Timed arm/disarm not allowed)
The factory setting is X=0 (Timed arm/disarm not
allowed)
Functions: The system can be set auto-arm or auto-disarm in certain
moment as required. After setting these function, auto-arm/ auto-disarm time
can be set. Refer to 9.3.17 and 9.3.18 for detail information.
-17-
Download PDF