Natural Comfort for Everybody AIR CONDITIONING SYSTEMS COMFORT TAKES ON NEW MEANING WITH THE POWER OF TECHNOLOGY Contents Our technologically advanced Mr. Slim Power Inverter systems improve comfort, operate with significantly less noise, .... and provide increased energy savings. NEW REFRIGERANT Product Line Up Page 3 Advanced Power Inverter Page 5 Advanced Technology Page 7 Control Technology Page 10 Product Series Page 15 Main Features Page 22 System Controls Page 23 Specifications Page 24 Product Line-up of Product Line-up 2.5kW 4-way Ceiling Cassette SLZ Series Compact cassette 3.5kW 5.0kW 6.0kW 7.1kW 10.0kW 12.5kW 14.0kW 17.0kW 20.0kW Inverter Units Remote controller 25.0kW optional for SLZ-VAQ optional for SLZ-VAQ 3-4 See page 21 SLZ-KA50VAQ (L) SLZ-KA25VAQ (L) standard for SLZ-VAL PLA Series optional optional 15 16 PLA-RP60BA Wide Power cassette PLA-RP100BA PLA-RP71BA PLA-RP125BA PLA-RP140BA optional Compact Bulkhead * Combination only with SUZ-KA71 SEZ Series optional for SEZ-VAQ SEZ-KD25VAQ (L) SEZ-KD35VAQ (L) SEZ-KD50VAQ (L) SEZ-KD60VAQ (L) optional for SEZ-VAQ 21 SEZ-KD71VAQ (L) standard for SEZ-VAL PEAD Series optional optional NEW PEAD-RP71JAA Ceilingconcealed PEAD-RP100JAA PEAD-RP125JAA 17 PEAD-RP140JAA optional for PEAD optional optional optional NEW PEA Series 18 NEW PEA-RP100GAA PEA-RP125GAA PEA-RP140GAA PEA-RP170WJA PEA-RP200WJA PEA-RP250WHA optional Ceilingsuspended PCA Series optional PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ optional 19 PCA-RP140KAQ optional Wallmounted * Combination only with PUHZ-RP71 PKA Series optional PKA-RP71KAL optional PKA-RP100KAL standard Outdoor unit SUZ-KA71VAD SUZ-KA25VAD SUZ-KA35VAD SUZ-KA50VAD SUZ-KA60VAD PUHZ-RP100V/YKA2 PUHZ-RP71VHA5 *SEZ/SLZ indoor units should be connected to an SUZ outdoor unit. *PKA-RP71: only for PUHZ-RP outdoor connection. *PEA-RP: No wireless remote controller as optional parts. PUHZ-RP125V/YKA2 PUHZ-RP140V/YKA2 PUHZ-RP170V/YKA2 PUHZ-RP200YKA2 PUHZ-RP250YKM 20 05-06 Advanced Power Inverter Demand Function Mitsubishi Electric’s Power Inverter systems increase energy efficiency. Based on the connection of a demand response enabling device (DRED) to the outdoor unit, Demand Response Mode is activated in response to signals sent from the electric authority at times when it is necessary to reduce peak demand. The units with service reference number PUHZ-RP•VHA5R1-A and PUHZ-RP•V/YKA2R1-A are demand response capable. This capability is possible with the connection of a demand response enabling device (DRED) to the terminal block interface (BT00C023G02). This item is supplied in a sealed bag located in the compressor chamber. Connection of the terminal block interface is a mandatory requirement for the installation of any PUHZ-RP•VHA5R1-A and PUHZ-RP•V/YKA2R1-A units. When installed the system is demand response capable; that is, ready to be connected to a demand response enabling device (DRED)*. To better meet the needs of shops and offices, our outdoor units are offered in three-phase power supply models in addition to the existing line-up of single-phase models. Select the model to best match your needs from our expanded model range. High Power Long Maximum Piping Length Advanced Power Inverter More Power for Faster Cooling/Heating The maximum piping length is 75m. Therefore there is a wide range of layout possibilities for unit installation. Powerful Cooling/Heating Performance Max. piping length Max. height difference Max. piping length (one-way) 30m 50m PUHZ-RP71 PUHZ-RP 100/125/140/170/200/250 The maximum operating cooling/heating capacity of the Mr. Slim Power Inverter units have been improved (compared to conventional non-inverter models) when operating in either low or high outdoor temperatures. Cooling capacity (kW) R22 Non-inverter 75m 30m * PUHZ-RP250 is excluded. Please contact Mitsubishi Electric Australia Pty. Ltd. for details. 71 class 7.7 8.1 105% 100 class 9.7 11.4 118% 125 class 12.4 14.0 113% 140 class 14.0 15.3 109% Heating capacity (kW) R22 Non-inverter PUHZ-RP71 High Energy Efficiency Air Conditioner Demand Response Mode Comparison of EER (cooling mode) Demand Response Mode (DRM) Description of operation in this mode DRM1 Compressor Off DRM2 The air conditioner continues to cool or heat during the demand response event, but the electrical energy consumed by the air conditioner in a half hour period is not more than 50% of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period. PUHZ-RP100/125/140/170/200 DRM3 Comparison of EER between non-inverter and Power Inverter (4-way ceiling cassette) models. The air conditioner continues to cool or heat during the demand response event, but the electrical energy consumed by the air conditioner in a half hour period is not more than 75% of the total electrical energy that would be consumed if operating at the rated capacity in a half hour period. 71 class 8.4 10.2 121% 100 class 10.4 14.0 135% 125 class 14.0 16.0 114% 140 class 16.1 18.0 112% 53% EER UP 4.00 4.0 Operation is now possible at lower speeds, thus cutting energy losses produced by the repeated On/Off operation of non-inverter models. Comfort is improved while power consumption is reduced. Cooling capacity ranges 80% 3.5 71 class 3.3-8.1 kW 3.40 57% UP 3.29 3.27 41% 32% UP 3.0 100 class 4.9-11.4 kW 125 class 5.5-14.0 kW UP 140 class 6.2-15.3 kW 2.47 PUHZ-RP250 0 2 4 6 2.0 71 Single-phase 100 125 140 170 200 250 DRM1 DRM2 DRM3 C Outdoor Unit 10 12 14 16 18kW 4-way ceiling cassette 71 class 3.5-10.2 kW 71 class 100 class 125 class 140 class 100 class 4.5-14.0 kW 125 class 5.0-16.0 kW Power Inverter Model Terminal block 8 Heating capacity ranges 2.22 2.17 Demand controller 4-way ceiling cassette UP 2.33 Outdoor unit 4-way ceiling cassette R410A Power inverter max. (PUHZ-RP) Wider Performance Range Average 2.5 Outdoor Line-up (PUHZ-RP series) 4-way ceiling cassette R410A Power inverter max. (PUHZ-RP) Non-inverter Model 140 class 5.7-18.0 kW Three-phase *EER are measured at rated condition. see specification on Page 24 0 2 4 6 8 10 12 14 16 18kW see specification on Page 24 Advanced Technology Cleaning-free Pipe Reuse Technology < PUHZ-RP71–200> Advanced Energy-efficient Technologies Ability to use existing piping reduces pipe waste and replacement time No Need to Clean at the Time of System Renewal Chloride residue builds up in existing pipes and becomes a source of trouble. In addition, the iron particles and slime produced as a result of compressor failure lead to problems. To counter this, various original Mitsubishi Electric technologies have been combined to enable the introduction of “cleaning-free pipe reuse.” This feature is available in the PUHZ-RP71-200 Why can’t existing piping be used? R22 refrigerant 1 Problem At time of renewal At time of compressor failure 07-08 2 Highly efficient fan and grille for outdoor unit Highly efficient heat exchanger The shapes of the fan and grille of the outdoor unit have been redesigned, realising an increase in blowing capacity and more efficient heat exchange while maintaining the same operating noise level. A high density and increase in surface area have improved the heat-exchange efficiency of the heat exchanger. Outdoor unit fan opening increased <PUHZ-RP100-200> High-density heat exchanger <PUHZ-RP100-200> The diameter of the opening for the fan in the outdoor unit has been increased from 490 to 550mm. Blowing capacity has been increased while maintaining the same fan rotation speed. The pipe diameter has been changed from 9.52 to 7.94mm, resulting in a high-density heat exchanger. R410A refrigerant Problem 2 lines, 52 columns Result 2 lines, 64 columns (RP100 –200) Chloride residue High heat generated during operation Increased chloride residue Accelerated deterioration of refrigerant oil Opening increased from 490 to 550mm in diameter Refrigerant circuit malfunctions and causes failure Iron particles and slime Heat-exchange surface area increased <PUHZ–RP100–200> Heat exchanger size extended horizontally, increasing the surface area. Increase in heat-exchanger surface area (image) Cleaning pipe or replacing with new pipe is required Grille shape changed <PUHZ-RP71-200> The shape of the air outlet grille has been changed to reduce pressure loss. This has helped to improve heat exchange performance. Mitsubishi Electric’s Original Replacement Technologies Heat exchanger Heat exchanger < PUHZ–RP • HA > < PUHZ–RP • KA > Heat Interchanger (HIC) Added <PUHZ-RP140> Countermeasure for Problem 1 Countermeasure for Problem 2 A HIC circuit has been added to improve energy efficiency during cooling operation. Liquid refrigerant is rerouted, transformed into a gas state and injected back into the system to increase overall pressure of the refrigerant being sent to the compressor, thereby reducing the load on the compressor and raising efficiency. Technology 2 Technology 1 Original High-quality Filtration Our original high-quality filtration device called the “Wide strainer” is equipped inside the refrigerant inlet and outlet pipe. The “Wide strainer” traps iron particles and provide cleaning-free pipe reuse. In addition, improvements to the metal used in the bearings of our new scroll compressors provide more robust units. “Wide strainer” Friction Reduction (moving parts in compressor) Friction inside the compressor is reduced by using an original Mitsubishi Electric technology called the “Heat Caulking Fixing Method” or coating the edge of the blade in the scroll compressor, thereby suppressing the increase in temperature that causes refrigerant oil deterioration. < PUHZ–RP • HA > < PUHZ–RP • KA > Cooling operation Inflexed fan <PUHZ-RP100-200> Indoor HEX Adoption of a fan with improved ventilation characteristics and a newly designed rear edge that suppresses wind turbulence raises fan operation efficiency. Existing piping can be used without cleaning A A w/ HIC circuit w/o HIC circuit Cautions when using existing piping • When removing an old air conditioning unit, please make sure to perform the pump-down process and recover the refrigerant and refrigerant oil. • Check to ensure that the piping diameter and thickness match Mitsubishi Electric specifications. • Check to ensure that the flare is compatible with R410A. see specification on Page 24 Heat interchanger (HIC) Outdoor HEX Power receiver LEV A LEV B Heat Interchanger (HIC) Compressor LEV C Increasing the pressure of the refrigerant sent to the compressor reduces the compression load Fan rear edge see specification on Page 24 09-10 Control Technology Full Dot Liquid-crystal Display Adopted PAR-31MAA Advanced Technology for High Efficiency Easier to read thanks to use of a full dot liquid-crystal display with backlight, and easier to use with a menu format that has reduced the number of operating buttons. Easy To Read & Easy To Use Multi-language Display Display Example [Operation Mode] MultiIanguage Full Dot LCD PAR-31MAA [English] Control panel operation in eight different languages Choose the desired language, among the following languages. [Spanish] [Italian] [German] [Russian] [Portuguese] [Swedish] Advanced Technology for High Efficiency Numerous Leading-edge Technologies Assure High Efficiency [French] Reluctance DC Rotary Compressor <PUHZ-RP71> DC Fan Motor <PUHZ-RP71–200> The reluctance DC motor has a rotor equipped with powerful neodymium magnets. The magnetic torque produced by the neodymium magnets and reluctance torque results in more efficient operation. A highly efficient DC motor has been installed to drive the fan of outdoor units, realising up to 60% higher efficiency when compared to an equivalent AC motor. Vector-Wave Eco Inverter DC compressor motor (rotor) This inverter monitors the varying compressor motor frequency and creates the most efficient waveform for the motor speed. As a result, operating efficiency in all speed ranges is improved and less power is used. Smooth AC wave pattern Neodymium magnets Magnetic torque + The inverter has been made more compact by inserting the circuitry inside a synthetic resin molding. To ensure quiet operation, soft PWM control is used to prevent the metallic whine associated with conventional inverters. Reluctance torque Sine-wave drive soft PWM <PUHZ-RP71–200> Higher efficiency has been achieved by adding a frame compliance mechanism to the DC scroll compressor. The mechanism allows movement in the axial direction of the frame supporting the cradle scroll, thereby greatly reducing the leakage and friction loss, and ensuring higher efficiency at all speeds. Thrust gas power: minimum Energyefficiency Schedule Precise control of power consumption <PUHZ–RP71–200> Using a temperature that is 1°C lower/higher for heating/cooling results in a 10% reduction in power consumption.* Temperature Range Restriction limits the maximum and minimum temperature settings, contributing to the prevention of overheating/overcooling. ■Setting pattern example 19(˚C) Auto-return Mitsubishi Electric has developed a power receiver and twin linear expansion valves (LEVs) that optimise the performance of the compressor. By ensuring optimum control in response to the operating waveform and outdoor temperature, this technology is tailored to the characteristics of the new refrigerant to enhance operating efficiency. Finish time 12:00 13:00 17:00 21:00 Adjusted capacity level 80% 50% 90% 50% Prevents wasteful operation by automatically returning to the preset temperature after specified operating time After adjusting the temperature for initial heating in winter or cooling on a hot summer day, it is easy to forget to return the temperature setting to its original value. The Auto-return function automatically resets the temperature back to the original setting after a specified period of time, thereby preventing overheating/overcooling. The Auto-return activation time can be set in 10-minute units, in a range between 30 and 120 minutes. Cradle scroll *Based on Mitsubishi Electric laboratory tests in controlled conditions Cooling/Dry Keep desired room temperatures automatically This function monitors the room temperature and automatically activates the heating mode when the temperature drops below the preset minimal temperature setting. It has the same function for cooling, automatically activating the cooling mode when the temperature rises above the preset maximum temperature setting. Primary back-pressure chamber minimises leaking loss. (Setting example of minimum temp. in 25°C) 30(˚C) Possible temperature range setting 25(˚C) To prevent excessive cooling Lower temperatures cannot be selected Auto-off Timer Office Restaurant Turns heating/cooling off automatically after preset time elapses When using Auto-off Timer, even if one forgets to turn off the unit, operation stops automatically after the preset time elapses, thereby preventing wasteful operation. Auto-off Timer can be set in 10-minute units, in a range between 30 minutes and 4 hours. Eliminating all anxiety about forgetting to turn off the unit. Recommended for Meeting room Operation Lock Changing room Fixed temperature setting promotes energy efficiency In addition to operation start/stop, the operation mode, temperature setting and airflow direction can be locked. Unwanted adjustment of temperature settings is prevented and an appropriate temperature is constantly maintained, leading to energy efficiency. This feature is also useful in preventing erroneous operation or tampering. Recommended for Office Hospital see specification on Page 24 30(˚C) Lower temperature limit *Auto-return cannot be used when Temperature Range Restrictions is in use. Night Setback Secondary back-pressure chamber minimises thrust friction loss. Temperature Range Restriction prevents overheating/overcooling The amount of power consumed in each time period is managed so that the demand value is not exceeded. The demand control function can be set to start and finish in 5-minute units. Additionally, the level can be adjusted to 0, 50, 60, 70, 80 or 90% of maximum capacity, and up to 4 patterns can be set per day. Air-conditioning operation is automatically controlled to ensure that electricity in excess of the contracted volume is not consumed. Thrust friction loss: minimum Frame Temperature Range Restriction Recommended for Power Receiver and Twin LEV Control <PUHZ-RP71–200> Leaking loss: minimum Operation Control Functions Start time 8:15 12:00 13:00 17:00 Highly Efficient DC Scroll Compressor Fixed scroll Energy-efficient Control School Public hall Computer server facility Control Technology Weekly Timer Set up to 8 patterns per day including temperature control Preparation 1 The Weekly Timer enables the setting of operation start and finish times and adjusting the temperature as standard features. Up to 8 patterns per day can be set, providing operation that matches the varying conditions of each period, such as the number of customers in the store. *Weekly Timer cannot be used when On/Off Timer is in use. Temperature setting (°C) 26 Busy hours Off-peak hours Set to lower temperature Set to higher temperature 7 25 Opening time 2 24 4 8 Lunch time Dinner time 5 8-pattern setting 22 0 10 12 14 16 18 20 22 Necessary to change temperature settings for cooling/heating times. *Joint research conducted by Mitsubishi Electric. MAC-558IF-E Closing time 6 3 23 New Wi-Fi Controller MAC-558IF-E Setting Example (restaurant in summer time) 11-12 24 (Time) Wi-Fi Control unlocks the door to smarter heating or cooling, for total home comfort wherever you are. This innovative technology connects your domestic high wall, floor mounted and ducted air conditioner to your smartphone, tablet or online account, giving you the freedom to fully control each unit on-the-go via an internet connection from anywhere in the world. CONTROL Key Features Rotation, Back-up and 2nd Stage Cut-in Functions (PAR-31MAA) <PUHZ-RP71–200> (1) Rotation and Back-up Functions Operation Pattern Function Outline • Main and Sub units take turns operating according to a rotation interval setting. • If one unit malfunctions, the other unit automatically begins operation (Back-up function). [Back-up function only] O/U-1 Main unit I/U-1 Run Abnormal condition Sub unit I/U-2 Stop Run Superior Customisation O/U-2 Main unit Sub unit I/U-1 R/C Error occurs on main unit. Main Sub Start operation System Image - View & Control from anywhere in the world -Enhance energy savings -Set up 7 days weekly schedule -Wireless connection using WPS Start operation O/U : Outdoor unit I/U : Indoor unit R/C : Wired remote controller Main Sub Sub Main Main unit I/U-1 Run Stop Run Sub unit I/U-2 Stop Run Stop 1–28 days (2) 2nd Stage Cut-in Function Error occurs on main unit. Main Sub Abnormal condition Run 1–28 days (When the request code is “313”, each unit operates alternately in daily cycle.) Function Outline • Number of units operating is based on room temperature and predetermined settings. • When room temperature rises above the desired setting, the standby unit starts (2-unit operation). • When the room temperature falls 4°C below the predetermined setting, the standby unit stops (1-unit operation). Room Temperature Limits Operation Pattern ( When cooling) [2nd stage cut-in function] Start operation System Constraint • This function is only available for rotation operation and when the back-up function is in cooling mode. Main unit I/U-1 Run Sub unit I/U-2 Stop Tailor your system to always meet your needs. Unlock the full potential of your air-conditioner, programme your system to automatically turn on/off at specific times, change settings, and develop temperature rules to ensure superior comfort day after day. This innovative technology places multiple functions of your air-conditioner at your fingertips. Turning the unit ON/OFF, adjusting set temperature, changing mode, fan speed and airflow direction are all possible. [Rotation function] & [Back-up function] I/U-2 Develop Operating Rules Room temp. > = Set point Sub unit starts operation With the ability to sense the room temperature and now automatically turn on of off to take the room to the desires temperature. Creating ultimate comfort for your home. Winter set minimum temperatures to warm up your home and Summer set maximum temperatures to create comfort cooling the room. Room temp. > = Set point –4°C Sub unit stops Run Stop Control Multiple Units Customise the settings of each air-conditioner in your home. Purchase multiple adaptors to manage all air-conditioners independently on the same account to ensure complete control over your system. The result is a tailored system to your needs. Minimum requirements Easy Maintenance Function <PUHZ-RP71–200> • Nearly maintenance-free operation • Monitor operation data of the indoor and outdoor units via the remote controller. Remote controller also lets you set the operating frequency, allowing easier inspection. Compressor Outdoor Unit Indoor Unit 1 Accumulated operating time (×10hr) 4 Heat exchanger temperature (˚C) 7 Intake-air temperature (˚C) 2 Number of ON/OFF times (×100 times) 5 Discharge temperature (˚C) 8 Heat exchanger temperature (˚C) 3 Operating current (A) 6 Outdoor-air temperature (˚C) 9 Filter operating time* (hr) *The filter operating time is the time elapsed since the filter button is reset. You will require a compatible WPS router with WPA2-AES encryption, with coverage including the air-conditioners installation location. A PC/Tablet/Smartphone that is iOS, Android compatible. A MAC-558IF-E adaptor per indoor unit. Compatible Mitsubishi Electric Air-conditioner. For a full list of requirements visit mitsubishielectric.com.au/wifi Available for Download Download the WiFi App from the App store or Google Play Control Technology New Zone Controller for PEAD/PEA Series PAC-ZC40/80L-E PAC-ZC40/80H-E Air intake Operation of up to 8 dampers and occupancy and brightness sensors provides greater comfort while improving energy-saving performance. Main screen Zone control screen WIP Oven Living Kitchen PEAD/ PEA Touch panel Air outlet Veranda Media Dining Porch Entry Bed 4 Robe WR Robe Robe Master suite Bed 3 Bed 2 Home theater Actual size: 120×140×25mm (H×W×D) Control operation of up to 8 dampers Easy to see and use By controlling the operation of up to eight dampers, the waste of operating air conditioning in unoccupied areas and areas where it is not needed can be prevented. Detailed control makes it possible to set operation to suit the user's needs. • A large, full-dot liquid-crystal screen is incorporated, greatly simplifying touch panel operation. • The backlight makes operation in dark rooms possible. Occupancy and brightness sensors The controller is equipped with a occupancy and brightness sensors that are used to determine if the room is occupied. When no one is in the room, operation switches to energy-saving mode. Excellent for ensuring that the air conditioning gets turned off, and thereby contributing to further energy savings. <Example> LED indicator The LED indicator in the lower part of the controller clearly shows the operation mode. Easily confirm if the air conditioning is on or off from a distance. *Set to all green display before shipping. Brightness sensor If room light is on, energy-saving control is deactivated. Occupancy sensor Judges whether or not someone is in the room by detecting human motion. If the room is unoccupied, air conditioning is switched to Energy-saving mode. When “Zone control” mode is selected among the energy-saving mode settings shown below. The damper is closed. Touch panel with backlight A 4.3-inch touch-panel liquid-crystal screen with a backlight has been incorporated. Temperature sensor Monitors the temperature near the remote controller. LED indicator Indicates the operation mode or room temperature using colours. *Setting is required. Schedule setting <Occupancy sensor> Wall PAR-ZC01M-E remote controller m 10 110° 10m PAR-ZC01M-E remote controller 10 m 11° 20° • Built-in weekly schedule function can control turning air conditioner on and off, and opening and closing of each damper. Up to eight patterns can be set for each week, enabling operation suitable for each time zone to be set. • Night setback function is incorporated. If the room temperature is outside of the temperature range setting, heating or cooling operation starts automatically. This can prevent condensation or excessive temperature rise in the room. Wi-Fi compatibility Can be operated from tablet, smartphone, etc. 31° Floor <Zone controller> PAC-ZC40H-E 240Volt 4 zones (max.) PAC-ZC80H-E 240Volt 8 zones (max.) <Energy-saving mode> PAC-ZC40L-E 24Volt 4 zones (max.) Energy-saving mode settings can be selected (see table below). PAC-ZC80L-E 24Volt 8 zones (max.) 110° Detection distance, right/left detection angle Deactivate Temperature setting slide Reduce airflow Operation/Stop Zone control Up/Down detection angle Even if no one is detected, Energy-saving mode is not set. Use slide to set desired temperature from presently set temperature. Set airflow to “Low”. Stop operation. Turn off target zone settings. <Optional parts> Wi-Fi Control Interface MAC-558IF-E Remote Sensor PAC-SE41TS-E Zone Remote Controller PAR-ZC01M-E 13-14 15 PLA Series PLA Series 4-way Ceiling Cassette Advancements in PLA series improve style and performance for ensured indoor comfort Auto Fan Speed Mode The fan speed is adjusted automatically, thereby helping to maintain a comfortable room environment at all times. At the start of operation, a high fan speed provides quick heating/cooling of the room. Once the desired temperature is reached, the fan speed is reduced for stable heating/cooling and greater comfort. Conventional model Wide Airflow Wide-angle outlets distribute airflow to all corners of the room, ensuring the room is sufficiently cooled/heated. Horizontal airflow and a fan speed reduced by 20% compared to conventional models also contribute to increased comfort for occupants. Lo PLA-RP ] ] BA Stylish, pure white-coloured panels and wired remote controller present a clean, streamlined image that is a suitable match for any interior. Using wired remote controller, set airflow direction for each vane (manual setting also possible) ] Wired remote controller (PAR-31MAA) has Independent Vane Direction Setting. This function is only available when indoor unit connects with PUHZ series. ■i-see Sensor Operation The i-see Sensor rotates 90° and takes 5-second measurements to accurately determine floor-level temperatures on all sides of the room. Other Features 90° rotation • Stylish indoor-unit vane covers (when unit is turned off ) • Maximum upward draining of 850mm • Wireless remote controller available • Duct flange for Fresh-air Intake • Branch duct Horizontal flow Set by remote controller Vertical flow Settings can be changed anytime using a wired remote controller. Automatic elevation to four metres Vertical Vertical Vertical Vertical flow flow flow flow Simultaneous horizontal and vertical operation ensure a comfortable room from corner to corner. 1.2m 1.6m • The i-see Sensor calculates the temperature by measuring the infrared rays emanating from “I Feel” Temperature Control The sensory temperature is calculated by measuring the air-intake temperature and the floor temperature. This technology helps to avoid overcooling or overheating. 2.4m Without i-see Sensor Only intake-air temperature at the ceiling is measured, resulting in uneven temperature distribution. 3.2m Packaged elevating (up-down) controller in the grille (PLP-6BAJ) can be used when indoor unit connects with PUHZ series and SUZ series. Temperature gap is decreased, and room is warmed uniformly Wired remote controller (PAR-31MAA) has automatic grille lowering function. This function is only available when indoor unit connects with PUHZ series. 3.6m With i-see Sensor Both floor-level and intake-air temperatures are measured, providing operation that creates a comfortable room environment from ceiling to floor. Indoor temperature Indoor temperature detecting sensor detecting sensor Indoor temperature Indoor temperature detecting sensor detecting sensor 4.0m 360° Area which the sensor checks sensing Indoor unit PLA-RP60BA Outdoor unit PLA-RP71BA SUZ-KA60VAD Capacity (min.-max.) (kW) Input (kW) PLA-RP71BA SUZ-KA71VAD PLA-RP100BA PUHZ-RP71VHA5 PLA-RP125BA PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2 PLA-RP140BA PUHZ-RP140V/YKA2 Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating 6.1 (2.3-6.3) 6.9 (2.5-8.0) 7.1 (2.8-8.1) 8.0 (2.6-10.2) 7.1 (3.3-8.1) 8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0) 4.43 1.78 1.97 2.07 2.19 2.09 2.17 2.50 2.95 3.80 3.71 3.97 Rated EER/COP 3.43 3.50 3.43 3.65 3.40 3.69 4.00 3.80 3.29 3.77 3.27 3.61 Rated AEER/ACOP 3.36 3.44 3.38 3.60 3.22 3.49 3.67/3.63 3.54/3.50 3.10/3.08 3.56/3.54 3.10/3.08 3.44/3.42 AEER/ACOP (part-load %) ] 4.13/4.05 Sound pressure level Dimensions CMM 12-14-16-18 14-16-18-21 14-16-18-21 20-23-26-30 22-25-28-31 24-26-29-32 L/S 200-233-267-300 233-267-300-350 233-267-300-350 334-384-434-501 367-417-467-517 400-434-484-534 (dB) 28-29-31-32 28-30-32-34 28-30-32-34 32-34-37-40 34-36-39-41 36-39-42-44 Unit: 258, Panel: 35 Height (mm) Width (mm) Unit: 840, Panel: 950 Depth (mm) Unit: 840, Panel: 950 Weight (kg) * MEPS compliant at part load * SUZ-KA •VAD is potentially demand response capable unit. DRC-101A is required. Sound Pressure Level • Sound pressure measurements were conducted in an anechoic chamber. • The actual noise level depends on the distance from the unit and the acoustic environment. Unit: 23, Panel: 6 Unit: 298, Panel: 35 Unit: 25, Panel: 6 11.5m 3.95/3.89 V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V Power supply Airflow (Lo-Mi2-Mi1-Hi) Area Areawhich whichthe the “i-see i-see Sensor” Sensor checks checks 2.7m Specifications: 4-way ceiling-cassette (PLA) Function 5sec measurement 2.0m Elevating (up-down) controller Swing mode 5sec measurement sensor rotates 360° once every two minutes when there is significant temperature disparity and once every five minutes when a stable, even temperature has been reached. 2.8m • Wave control effect thermograph 5sec measurement 90° rotation the walls and floors, and measuring the floor-level temperature. Easy to use/Simple maintenance An automatic grille lowering function capable of stopping at eight different heights is available to simplify filter maintenance. “Wave Airflow” operation image 5sec measurement 90° rotation • The Automatic Grille Lowering Function (Option) Wave Airflow Mode for Heating Temperature gap with uneven temperature distribution Power flow fan i-see Sensor improves energy efficiency and enhances room comfort (Option) The i-see Sensor is an innovative Mitsubishi Electric technology that uses a radiation-based sensor to monitor temperature throughout the entire room. When connected to the air conditioner control panel, i-see Sensor works to maximise room comfort through 360° sensing that covers the whole floor space. “Pure White” Colour Fixed Vertical flow Auto An improved airflow path and powerful highcapacity flow fan contribute to the realisation of quieter operation. Use the wired remote controller to set the airflow pattern of each vane independently. Easily adjust airflow to the interior layout and seasonal conditions, to help ensure an even temperature distribution. The airflow direction at each outlet changes intermittently, providing a consistent temperature throughout the room. Hi 360° Floor-level temperature measured throughout the room. Quiet Operation The horizontal airflow function prevents cold drafts from striking the body directly, thereby keeping the body from becoming over-chilled. Independent Vane Direction Setting optional Mi1 ]Special setting is required for wireless remote controller. Horizontal airflow prevents drafty feeling PLA-RP60/71 100/125/140BA Mi2 4-way cassettes can be equipped with the i-see Sensor, a radiation-based sensor that monitors floor-level temperatures throughout the room to ensure room comfort. i-see Sensor works to ensure even temperature distribution and save energy (requires optional corner panel) Fan speed setting by remote controller (four levels) Less Cold Draft (i-see Sensor: optional) 16 Unit: 27, Panel: 6 Heating Heating Set temperature: 23°C without i-see Sensor Set temperature: 20°C with i-see Sensor + Auto Fan Speed 37°C 37°C 25°C 25°C 13°C 13°C 17 18 PEAD Series Ceilingconcealed The thin, ceiling-concealed indoor units of the PEAD series are the perfect answer for the air conditioning requirements of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energy-saving efficiency has been improved, thereby reducing electricity consumption and contributing to a further reduction in operating cost. PEA Series Ceilingconcealed Compact Indoor Units Versatile and easy installation is possible; for example, it is possible to adjust the distance between the air-intake and air-outlet vents to create the optimal airflow configuration. ■ Long rectangular room Height reduced by 250mm 178mm PEAD-RP71-140JAA NEW (7.1kW-14.0kW) models, unit Compared to the previous weight has been reduced by an average of 27kg. This significant weight reduction allows for increased ease of installation. optional optional optional PEA-RP100/125/140GAA Wide Selection of Fan Speeds and External Static Pressure fixtures ■ L-shaped room A flexible duct design and 150Pa external static high-pressure are incorporated. The increased variation in airflow options ensures operation that best matches virtually all room layouts. PEA-RP • EAQ PEAD-RP71/100/125/140JAA ■ Room with fixed ceiling Flexible Duct Design Enables Use of High-pressure Static Fan up to Lighter Weight NEW Freedom in Installation PEA-RP170/200WJA/250WHA The height of the PEAD (7.1kW-14.0kW) models has been unified to 250mm. Compared to the previous PEA-RP models, the height has been reduced by as much as 178mm, making installation possible in low ceilings with minimal clearance space. PEA-RP71-140EAQ For elegance and style, the PEA series compliments the room environment with aesthetically pleasing ceiling installation and a vast line-up of performance functions. optional Five-stage external static pressure conversions and three fan speed selections are available. Capable of being set to a maximum of 125Pa, units are applicable to a wide range of building types. Easier Handling High Energy-Saving Efficiency The new ducted fan coil unit (PEA-RP170/200/250) now has a two-piece construction. This allows separation of the indoor unit heat exchanger and the fan deck assembly for easier handling into the roof space. Compared to the previous PEA-RP • EAQ (7.1kW-14.0kW) models, PEAD-RP models achieve enhanced energy efficiency through adopting a highly efficient DC fan motor. This contributes to a reduction in electricity consumption. Capacity Previous PEA-RP PEAD-RP Rated EER 2.86 3.50 22% UP Rated COP 3.35 4.00 19% UP Rated EER 3.28 3.61 10% UP Rated COP 3.54 4.12 16% UP Rated EER 2.95 3.33 13% UP Rated COP 3.64 4.00 10% UP Rated EER 2.90 3.32 14% UP Rated COP 3.74 3.96 6% UP Rated EER/COP 7.1kW 10.0kW 12.5kW 14.0kW Specifications: Ceiling-concealed (PEAD) Must be reassembled and installed prior to using the system. Computerised Dehumidification The fan speed is controlled electronically in dehumidifying mode, increasing the range and efficiency of dehumidification. Specifications: Ceiling-concealed (PEA) Indoor unit PEAD-RP71JAA PEAD-RP71JAA PEAD-RP100JAA PEAD-RP125JAA PEAD-RP140JAA Outdoor unit SUZ-KA71VAD PUHZ-RP71VHA5 PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2 PUHZ-RP140V/YKA2 Function Capacity (min.-max.) (kW) Input (kW) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating 7.1 (2.8-8.1) 8.0 (2.6-10.2) 7.1 (3.3-8.1) 8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.0 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0) Indoor unit Outdoor unit PEA-RP100GAA PEA-RP125GAA PEA-RP140GAA PEA-RP170WJA PEA-RP200WJA PEA-RP250WHA PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2 PUHZ-RP140V/YKA2 PUHZ-RP170V/YKA2 PUHZ-RP200YKA2 PUHZ-RP250YKM Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min.-max.) (kW) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 13.5 (6.2-15.3) 16.0 (5.7-18.0) 16.0 (9.0-20.0) 20.0 (9.5-22.4) 18.9 (9.0-22.4) 22.4 (9.5-25.0) 22.0 (11.2-27.0) 25.0 (12.5-29.0) (kW) 6.89 Function 2.10 2.04 2.03 2.00 2.77 2.72 3.60 3.50 3.91 4.04 Input 2.60 2.51 3.97 3.27 4.19 3.90 5.00 6.00 5.92 6.89 6.11 Rated EER/COP 3.38 3.92 3.50 4.00 3.61 4.12 3.33 4.00 3.32 3.96 Rated EER/COP ]1 3.85 4.46 3.15 4.28 3.22 4.10 3.20 3.33 3.19 3.25 3.60 3.62 Rated AEER/ACOP 3.33 3.86 3.31 3.78 3.34/3.31 3.81/3.78 3.14/3.11 3.76/3.74 3.09/3.07 3.76/3.73 Rated AEER/ACOP 3.54/3.51 4.11/4.07 2.98/2.96 4.01/3.98 3.06/3.04 3.88/3.86 3.16/3.11 3.22/3.18 3.04 3.12 3.27 3.37 3.68/3.63 AEER/ACOP (part-load %) ] 17.5-21-25 24-29-34 29.5-35.5-42 32-39-46 L/S 292-350-417 400-483-567 492-592-700 533-650-767 Sound pressure level (dB) 30-34-39 33-38-42 36-40-44 40-44-49 Return air spigot size (mm) 1,058×210 1,358×210 1,358×210 (mm) 1,060×178 1,360×178 1,360×178 Supply air spigot size Dimensions Weight Height (mm) Width (mm) 34-42 50Pa: 48-60, 100Pa: 43-54, 150Pa: 41-52 50-61-72 58-71-84 L/S 560-700 50Pa: 800-1,000, 100Pa: 716-900, 150Pa: 683-866 833-1,017-1,200 967-1,183-1,400 Sound pressure level ]3 (dB) 39-42 1,558×210 Return air spigot size (mm) 1,102×330 1,100×420 1,560×178 Supply air spigot size 1,100×340 Depth (mm) (kg) Airflow (Lo-[Mid]-Hi) External static pressure Pa 250 1,400 1,100 1,600 Dimensions 732 29 38 39 3.71 V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V CMM 35/50/70/100/125 External static pressure Pa 3.67/3.61 Power supply CMM Airflow (Lo-Mid-Hi) 3.69/3.63 AEER/ACOP (part-load %) ]2 V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V Power supply 43 * MEPS compliant at part load * SUZ-KA •VAD is potentially demand response capable unit. DRC-101A is required. Sound Pressure Level • Sound pressure measurements were conducted in an anechoic chamber. • The actual noise level depends on the distance from the unit and the acoustic environment. Weight 60/75/100/150 50/100/150 42-45 40-43-46 38-41-44 (mm) 921×250 Height (mm) 400 470 Width (mm) 1,400 1,370 Depth (mm) 634 1,120 (kg) 63 108 *1 Rated EER/COP for PEA-RP170/200WJA/250WHA are measured at ESP 75 Pa. *2 MEPS compliant at part load *3 Sound pressure level for PEA-RP125/140GAA are measured in anechoic chamber at ESP 50 Pa. Sound pressure level for PEA-RP170/200WJA/250WHA are measured in anechoic chamber at ESP 150 Pa. 19 20 PCA Series Ceilingsuspended A stylish indoor unit design and airflow settings for both high- and low-ceiling interiors expand installation possibilities Stylish Indoor Unit Design PCA-GA A stylish square-like design is adopted for the indoor units of all models. As a result, the units blend in better with the ceiling. PKA Series Wallmounted Elegant design and compact dimensions are ideal for offices, stores and residential-use Auto-flap Shutter Closing automatically when the air conditioner is not running creating a flat surface that is aesthetically appealing. Quick Clean Grille PCA-KA Optional Drain Pump for Full-capacity Models The intake grille filter can easily slide out completely, allowing easy cleaning without any special tools making it easy to clean in minutes, washing in water. Drain pump installation possible Drainage outlet can be 600mm above ceiling surface The pumping height of the optional drain pump has been increased from 400mm to 600mm, expanding flexibility in choosing unit location during installation work. Ceiling surface Front grille Equipped with Automatic Air-speed Adjustment Filter In addition to the conventional 4-speed setting, units are now equipped with an automatic air-speed adjustment mode. This setting automatically adjusts the air-speed to conditions that match the room environment. At the start of heating/cooling operation, the airflow is set to high-speed to quickly heat/cool the room. When the room temperature reaches the desired setting, the airflow speed is decreased automatically Strong Gentle for stable comfortable heating/cooling operStart of After room cooling/heating… temperature is stabilised… ation. PCA-RP50/60/71/100/125/140KAQ optional Fresh Outside-air Intake Static pressure (Pa) l Outside-air intake characteristics Units are equipped with a knockout hole that enables the induction of fresh outside-air. 50 0 –50 –100 –150 –200 –250 –300 1 2 3 Airflow volume (m3/min) 4 Equipped with High- /Low-ceiling Modes Units are equipped with high- and low-ceiling operation modes that make it possible to switch the airflow volume to match room height. The ability to choose the optimum airflow volume makes it possible to optimise the breezy sensation felt throughout the room. Capacity 4-way Piping Provides More Flexibility in Selecting Installation Sites optional standard Wired Remote Controller Available (Option) A separately sold wired remote controller and a terminal block are available to suit various installation sites. Drain Pump Option Available with All Models PCA-RP100–140KA PCA-RP60/71KA PCA-RP50KA 0 PKA-RP71/100KAL Installation of the drain pump enables a drain outlet as high as 800mm above the base of the indoor unit. Drain water can be discharged easily even if the surface where the wall-mounted unit does not have direct access outside, increasing the degree of freedom for installation. High Standard Low ceiling ceiling ceiling 50 3.5m 2.7m 2.5m 60 3.5m 2.7m 2.5m 71 3.5m 2.7m 2.5m 100 4.2m 3.0m 2.6m 125 4.2m 3.0m 2.6m 140 4.2m 3.0m 2.6m Drain pump Indoor unit 800mm Specifications: Ceiling-suspended (PCA) Indoor unit PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ Outdoor unit SUZ-KA50VAD SUZ-KA60VAD SUZ-KA71VAD PUHZ-RP71VHA5 PUHZ-RP100V/YKA2 PUHZ-RP125V/YKA2 PUHZ-RP140V/YKA2 Cooling Heating Capacity (min.-max.) (kW) 4.9 (2.3-5.6) 5.5 (1.7-7.2) Input (kW) 1.49 1.68 Function Cooling Heating 5.7 (2.3-6.3) 6.9 (2.5-8.0) 1.67 2.02 Cooling Heating Cooling Heating Cooling Heating Cooling Heating 7.1 (2.8-8.1) 7.9 (2.6-10.2) 7.1 (3.3-8.1) 8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.0 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0) 2.06 1.96 1.96 2.21 2.63 3.02 3.66 3.88 3.97 4.43 Capacity (min.-max.) (kW) Input (kW) 3.29 3.27 3.41 3.42 3.45 4.03 3.62 3.62 3.80 3.71 3.28 3.61 3.27 3.61 Rated AEER/ACOP 3.22 3.22 3.35 3.36 3.39 3.96 3.42 3.44 3.50/3.47 3.46/3.43 3.09/3.07 3.41/3.39 3.10/3.08 3.41/3.39 AEER/ACOP (part-load %) ] 4.19/4.11 Dimensions Weight 3.91/3.85 V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V Power supply Sound pressure level 10-11-13-15 15-16-17-19 16-17-18-20 22-24-26-28 23-25-27-29 24-26-29-32 L/S 167-183-217-250 250-267-283-317 267-283-300-333 367-400-433-467 383-417-450-483 400-433-483-533 (dB) 32-34-37-40 33-35-37-40 35-37-39-41 37-39-41-43 39-41-43-45 41-43-45-48 (mm) Width (mm) Depth (mm) (kg) Outdoor unit Function 1,600 1,280 32 Cooling Heating Cooling Heating 8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 1.96 2.13 2.90 3.10 3.62 3.76 3.45 3.61 Rated AEER/ACOP 3.42 3.56 3.20/3.17 3.34/3.31 V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V Airflow (Lo-Mid-Hi) Sound pressure level Dimensions 680 25 36 38 39 * MEPS compliant at part load * SUZ-KA •VAD is potentially demand response capable unit. DRC-101A is required. Sound Pressure Level • Sound pressure measurements were conducted in an anechoic chamber. • The actual noise level depends on the distance from the unit and the acoustic environment. PKA-RP100KAL PUHZ-RP100V/YKA2 Rated EER/COP 230 960 PKA-RP71KAL PUHZ-RP71VHA5 7.1 (3.3-8.1) Power supply CMM Height Indoor unit Heating Rated EER/COP Airflow (Lo-Mi2-Mi1-Hi) Specifications: Wall-mounted (PKA) Cooling Weight CMM 18-20-22 20-23-26 L/S 300-333-367 333-383-433 (dB) 39-42-45 41-45-49 Height (mm) 365 Width (mm) 1,170 Depth (mm) 295 (kg) 21 Sound Pressure Level • Sound pressure measurements were conducted in an anechoic chamber. • The actual noise level depends on the distance from the unit and the acoustic environment. 21 SLZ /SEZ Series 22 Main Features 4-way Ceiling Cassette Compact Bulkhead Compact, quiet concealed indoor units equipped with cutting-edge control technologies for enhanced comfort Main features of Mr. Slim Inverter Units Indoor unit Compact Designs SLZ-KA25/50VAQ (L) SLZ-VAQ SLZ-VAL SEZ-VAQ SEZ-VAL SUZ SUZ SUZ SUZ PLA Combination Outdoor unit Models with capacity ranges for any room size. The dimensions of the SLZ are perfect for 2-metre-square installations, and the SEZ unit is a slim 200mm in height, making it ideal for tight installation spaces. Standard Energy Saving Felt Temperature Control (i-see Sensor) Demand Function PUHZ O O O O O *7 PEA PKA *7 *7 PUHZ-KA PUHZ-YKM PUHZ PEAD SUZ PUHZ *7 SUZ O Optional Not Available PCA-KAQ *7 PUHZ *7 SUZ O O O O *4 Pure White 990mm Attractive 700mm 208mm Auto Vane 200mm 650mm Fresh-air Intake 650mm SLZ-KA25/50 SEZ-KD35/50 Impressively Quiet Air Quality S series units offer quiet operation at a hushed noise level of 23dB (SEZ-KD25/35), ensuring a calm and comfortable environment. They’re so quiet that you may find yourself checking to see if they’re on. optional for SLZ/SEZ-VAQ Quiet passenger car interior (40km/h) Subway car interior SEZ-KD25/35/50/60/71VAQ (L) O O O Oil Mist Filter Long-life Filter O Filter Check Signal Horizontal Vane (Auto Swing) l Noise level optional for SLZ/SEZ-VAQ O High-efficiency Filter Human hearing limits (Extremely quiet) Sound of rustling leaves Library interior High Ceiling Mode Air Distribution 80dB standard for SLZ-VAL 60dB 40dB 10dB 23dB Low Ceiling Mode Quiet! standard for SEZ-VAL Auto Fan Speed Mode Energy-saving Operation Auto Change Over *1 Auto Restart Air Cleaning Filter Convenience Low-temperature Cooling This built-in filter removes dust and other particulates helping to keep the air clean. Maintenance is as simple as vacuuming. The long-life filter in SLZ series air conditioners can be used for approximately 2,500 hours before requiring replacement. Fresh-air intake 25 100 118 3- 2.8 hole Burring hole Rotation, Back-up and 2nd Stage Cut-in Function ° Electrical box Refrigerant pipe Drain pipe 73.4 Cut-out hole O O O PAR-31MAA Control *2 O O O O O O O O O O O O PAC-YT52CRA Control *2 O O O O O O O O O O O O O O O O 0° 120 A duct hole is provided in the main body, making it possible to intake fresh air from outside. Low-noise Operation (Outdoor Unit) Detail drawing of fresh-air intake 12 Fresh-air Intake *5 On/Off Operation Timer Boasting low electricity consumption, SLZ/SEZ series air conditioners are the key to fresh, cost-effective room comfort. System Control PAC-ZC40/80H (L)-E Control Ceiling surface System Group Control *2 O O O O M-NET Connection *2 O O O O O O O O O O O O O O O O O O O O Specifications: 4-way cassette / Compact ceiling-concealed (SLZ, SEZ) Indoor unit Outdoor unit SLZ-KA25VAQ(L) SLZ-KA50VAQ(L) SEZ-KD25VAQ(L) SEZ-KD35VAQ(L) SEZ-KD50VAQ(L) SEZ-KD60VAQ(L) SEZ-KD71VAQ(L) SUZ-KA25VAD SUZ-KA50VAD SUZ-KA25VAD SUZ-KA35VAD SUZ-KA50VAD SUZ-KA60VAD SUZ-KA71VAD Cooling Function Capacity (min.-max.) (kW) 2.3 (1.5-3.2) Input (kW) 0.6 Heating Cooling 3.1 (1.3-4.5) 4.2 (2.3-5.2) 0.82 Heating Cooling 4.5 (1.7-6.5) 2.5 (1.5-3.2) 1.27 1.37 0.75 Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating 3.0 (1.3-4.5) 3.7 (1.4-3.9) 4.2 (1.7-5.0) 5.1 (2.3-5.6) 6.4 (1.7-7.2) 5.6 (2.3-6.3) 7.4 (2.5-8.0) 6.5 (2.8-8.3) 8.1 (2.6-10.4) 0.83 1.09 1.13 1.64 1.81 1.77 2.05 2.06 2.18 Rated EER/COP 3.83 3.78 3.31 3.28 3.33 3.61 3.39 3.72 3.11 3.54 3.16 3.61 3.16 3.72 Rated AEER/ACOP 3.65 3.66 3.23 3.22 3.21 3.49 3.31 3.62 3.05 3.48 3.11 3.55 3.10 3.66 AEER/ACOP (part-load %) ] 4.32 Airflow (Lo-Mid-Hi) 8-9-10 8-9-11 5.5-7-9 7-9-11 10-12.5-15 12-15-18 12-16-20 L/S 133-150-167 133-150-183 92-117-150 117-150-183 167-208-250 200-250-300 200-267-333 Maintenance 5/15/35/50 Sound pressure level (dB) Supply air spigot size (mm) — 660×150 860×150 1,060×150 Height (mm) Unit: 235, Panel: 20 200 200 200 Width (mm) Unit: 570, Panel: 650 790 990 1,190 Depth (mm) Unit: 570, Panel: 650 700 (kg) Unit: 16.5, Panel: 3 18 Weight Sound Pressure Level 28-31-37 30-34-39 • Sound pressure measurements were conducted in an anechoic chamber. • The actual noise level depends on the distance from the unit and the acoustic environment. 23-26-30 30-34-37 23-28-33 700 21 O Flare Connection CMM — O Pump Down Switch 3.72 External static pressure Pa Dimensions Drain Pump 30-34-38 30-35-40 700 23 27 * MEPS compliant at part load * SUZ-KA •VAD is potentially demand response capable unit. DRC-101A is required. O Installation V: Single-phase, 50Hz, 230V Power supply O Reuse of Existing Wiring *3 Self-Diagnosis Function (Check Code Display) Failure Recall Function *1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible. *2 Please refer “System Control” on page 21 for details. *3 Not available with PEA-RP170/200WJA and PEA-RP250WHA models. *4 Schedule timer not available External contact only *6 *5 Remote controller timer function only *6 Only error display on remote controller *7 PUHZ-RP250 is excluded. PUHZ-RP • VHA5R1-A, PUHZ-RP • V /YKA2R1-A are only demand response capable with the demand function. Please contact Mitsubishi Electric Australia Pty. Ltd. for details. O 23 System Controls Specifications System Controls (SUZ and Mr. Slim Power Inverter only) Versatile system controls can be realised by using optional parts, relay circuits, control panels, etc. 24 Specification: Outdoor Unit MAJOR SYSTEM CONTROL Outdoor unit System Examples Indoor Unit S Series & P Series Indoor Unit P Series Indoor Unit S Series Outdoor P Series Outdoor Outdoor Unit A Details PAR-31MAA Control PAC-YT52CRA Control Standard equipment (for indoor units compatible with wired remote controllers) Major Optional Parts Required • PAR-31MAA (Wired remote controller) • PAC-YT52CRA (Wired remote controller) System Group Control MAC-397IF-E MAC-333IF-E PAR-31MAA PAC-YT52CRA PAR-31MAA PAC-YT52CRA C M-NET Connections Outdoor unit Outdoor unit Indoor unit Indoor unit Indoor unit City Multi indoor unit PAR-31MAA PAC-YT52CRA Indoor unit PAR-31MAA PAC-YT52CRA PAR-31MAA PAC-YT52CRA • One remote controller can control plural air conditioners with the same settings simultaneously. • One remote controller can control up to 16 refrigerant systems. • Up to two remote controller can be connected. • Group of air conditioners can be controlled by MELANS system controller (M-NET). PAR-31MAA PAC-YT52CRA MELANS system controller AE-200E <P Series Outdoor Unit> • PAR-31MAA (Wired remote controller) <S Series Outdoor Unit> • MAC-333IF-E • MELANS System controller <P Series Outdoor Unit> • PAC-SF83MA-E (M-NET converter) • MELANS System controller MAC-333IF-E MELANS system controller AE-200E <S Series Outdoor Unit> • MAC-397IF-E/MAC-333IF-E (Interface) • PAR-31MAA (Wired remote controller) • PAC-YT52CRA (Wired remote controller) M-NET adapter PAC-SF81MA-E SUZ-KA35VAD SUZ-KA50VAD External finish Munsell 3.0Y 7.8/1.1 Power supply Single-phase, 50Hz, 230V (kW) 0.9 0.9 1.2 34 (568)/32 (534) 33 (551) 49 (817) 58 (960)/49 (816) 57 (950)/48 (800) Cooling mode 46 47 53 55 Heating mode 46 48 55 55 59 61 68 69 CMM (L /S) (dB) Sound level Dimensions SUZ-KA71VAD 0.65 Airflow (cooling/heating) Sound pressure level (dB) SUZ-KA60VAD 0.55 Compressor output PAR-31MAA PAC-YT52CRA B SUZ-KA25VAD Height (mm) 550 850 880 Width (mm) 800 840 840 Depth (mm) 285 330 330 Weight (kg) Chargeless piping length (m) Max. piping length (m) 20 30 Breaker size (A) 10 20 30 33 50 53 53 7 FOR P SERIES AND S SERIES INDOOR UNITS *Above specifications are for outdoor units only. System Examples Wired remote controller A Wireless remote controller 2-remote Controller Control • Up to two remote controllers can be connected to one group. With two remote controllers, control can be performed locally and remotely from two locations. PAR-SL97A-E PAR-31MAA PAC-YT52CRA PAR-31MAA PAC-YT52CRA * Set "Main" and "Sub" remote controllers. (Example of 1 : 1 system) B Operation Control by Level Signal Air conditioner can be started/ stopped remotely. In addition, On/Off operation by local remote controller can be prohibited/permitted. Remote control panel Wired remote controller Operation Control by Pulse Signal Adapter for remote On/Off Remote control panel Remote operation adapter/ Connector cable for remote display + Relay box PACYT52CRA PAR-31MAA (Example of 1 : 1 system) E Timer Operation Allows On/Off operation with timer *For control by an external timer, refer to B Operation Control by Level Signal. PAR-31MAA (Example of 1 : 1 system) • Adapter for remote On/Off PAC-SE55RA-E • Operation other than On/Off (e.g., adjustment of temperature, fan speed, and airflow) can • Relay box (to be purchased locally) • Remote control panel (to be purchased be performed even when remote controller locally) operation is prohibited. • Timer control is possible with an external timer. Outdoor unit PUHZ-RP71VHA5 Relay box (to be purchased locally) Connector cable for remote display Remote control panel • The pulse signal can be turned On/Off. • Operation/emergency signal can be received at a remote location. • Connector cable for remote display PAC-SA88HA-E / PAC-725AD (10 pcs. x PAC-SA88HA-E) • Relay box (to be purchased locally) • Remote control panel (to be purchased locally) PUHZ-RP125V/YKA2 Munsell 3.0Y 7.8/1.1 Power supply V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V (kW) Compressor output Sound pressure level (dB) PUHZ-RP140V/YKA2 1.6 1.9 60 (1,000) 110 (1,830) Cooling mode 47 49 50 50 Silent mode 44 46 47 47 Heating mode 48 51 52 52 (dB) 66 69 70 70 Height (mm) 943 1,338 Width (mm) 950 1,050 Depth (mm) 330 330 (kg) 67 CMM (L /S) 2.4 2.9 120 (2,000) PAR-SL97A-E Sound level (Example of 1 : 1 system x 2) Remote operation adapter/ Connector cable for remote display + Relay box Remote display panel PUHZ-RP100V/YKA2 External finish Airflow (cooling/heating) PAR-SL97A-E Operating status can be displayed at a remote location. Remote display panel • Wired Remote Controller PAR-31MAA PAC-YT52CRA (for PKA, PAC-SH29TC-E is required) • Wireless Remote Controller PAR-SL97A-E (for SEZ and PLA-RP) • Wireless Remote Controller Kit for PCA PAR-SL94B-E (Example of 1 : 1 system x 2) Connector cable for remote display (Example of 1 : 1 system x 2) Remote Display of Operating Status Relay box (to be purchased locally) Relay box (to be purchased) locally) Wired remote controller • Both wired and wireless remote controllers can be used in combination. Major Optional Parts Required (Example of Simultaneous Twin) Adapter for remote On/Off Remote control panel D * When using wired and wireless remote controllers Relay box (to be purchased) locally) (Example of 1 : 1 system x 2) C Details • Operation/emergency signal can be received at a remote location (when channeled through the PAC-SF40RM no-voltage signal, when channeled through the PAC-SA88HA-E DC 12V signal). • Remote display panel (to be purchased locally) • Connector cable for remote display PAC-SA88HA-E / PAC-725AD (10 pcs. x PAC-SA88HA-E) • Relay box (to be purchased locally) • Remote operation adapter PAC-SF40RM *Unable to use with wireless remote controller PAR-SL97A-E Dimensions Weight V: 118 Y: 119 V: 120 Y: 121 Sound Pressure Level (Example of Simultaneous Twin) • Weekly Timer: On/Off and up to 8 pattern temperatures can be set for each calendar day. (Initial setting) • On/Off Timer: On/Off can be set once each within 72hr. in intervals of 5-minute units. • Auto-off Timer: Operation will be switched off after a certain time elapse. Set time can be changed from 30 min. to 4 hr. at 10 min. intervals. *Simple Timer and Auto-off Timer cannot be used at the same time. Standard functions of PAR-31MAA Chargeless piping length (m) 30 • Sound pressure measurements were conducted in an anechoic chamber. 30 Max. piping length • The actual noise level (m) depends on the distance 50from the unit and the acoustic environment. 75 Protection device Discharge thermo, HP switch Rated running current (cooling/heating) (A) 9.05/9.64 Breaker size (A) 25 V: 12.64/13.58 Y: 4.42/4.75 Sound Pressure Level • Sound pressure measurements were conducted in an anechoic chamber. • The actual noise level depends on the distance from the unit and the acoustic environment. V: 16.36/16.90 Y: 5.73/5.91 V: 32 Y: 16 V: 17.17/19.23 Y: 6.01/6.73 V: 40 Y: 16 *Above specifications are for outdoor units only. 25 Specifications Optional Parts Specifications: Outdoor Unit Optional Parts Part name PEAD-RP140 i-see sensor corner panel PAC-SA1ME-E PLA-RP Shutter plate PAC-SH51SP-E PLA-RP 9.52‘ 12.7 PAC-SG73RJ-E PUHZ-RP71/100/125/140/170/200 15.88 19.05 PAC-SG75RJ-E PUHZ-RP71/100/125/140 M-NET converter PAC-SF83MA-E PUHZ-RP71/100/125/140/170/200 Multi-function casement PAC-SH53TM-E PLA-RP PCA-RP50KAQ PAC-SG94HR-E PKA-RP PAC-SH84DM-E PCA-RP71/100/125/140KAQ PAC-SG96HR-E PCA-RP50/60/71/100/125/140KAQ PAC-SH85DM-E PCA-RP60KAQ PAC-SG97HR-E PEAD-RP, PEA-RP PAC-KE07DM-E SEZ-KD PAC-SH52HR-E PLA-RP Drain socket PAC-SG61DS-E PUHZ-RP71/100/125/140/170/200 Remote On/Off adaptor PAC-SE55RA-E All indoor units PAC-SH65OF-E PLA-RP Remote operation adaptor PAC-SF40RM-E All indoor units*2 (excluding PKA-RP) Air protection guide Munsell 3.0Y 7.8/1.1 Munsell 3.0Y 7.8/1.1 Munsell 5.0Y 8.0/1.0 or Similar Control/service tool 3.0 CMM (L /S) Cooling mode Sound pressure level (dB) 6.9 140 (2,330) 140 (2,330) 175 (2,917) 58 58 58 56 Silent mode 56 Drain pump 48 PAC-SG59SG-E PUHZ-RP71 PAC-SH96SG-E PUHZ-RP100/125/140/170/200 PAC-SH51SP-E PLA-RP PAC-SH63AG-E PUHZ-RP71 PAC-SH95AG-E PUHZ-RP100/125/140/170/200 PAC-SK52ST PUHZ-RP71/100/125/140/170/200 PAC-SG64DP-E PUHZ-RP71 PAC-SH97DP-E PUHZ-RP100/125/140/170/200 PAC-SH94DM-E PKA-RP PAC-SH83DM-E Filter box Joint pipe Power supply terminal kit 59 59 58 Flange for fresh-air intake (dB) 76 76 78 Liquid refrigerant dryer for pipe ø9.52 PAC-SG82DR-E PUHZ-RP Remote sensor PAC-SE41TS-E All indoor units (excluding PEA-RP • GAA) Height (mm) 1,338 1,338 1,650 Wi-Fi interface MAC-558IF-E All indoor units (excluding PEA-RP250WHA) Space panel PAC-SH48AS-E PLA-RP Width (mm) 1,050 1,050 920 Terminal block PAC-SH29TC-E PKA-RP for wired remote controller MAC-397IF-E SLZ-KA, SEZ-KD, PLA-RP60/71*1 PEAD-RP71*1, PCA-RP50/60/71*1 Connector cable for remote display PAC-SA88HA-E All indoor units PAR-31MAA MAC-399IF-E SLZ-KA, SEZ-KD, PLA-RP60/71*1 PEAD-RP71*1, PCA-RP50/60/71*1 All indoor units (excluding SLZ-VAL and SEZ-VAL) PAC-YT52CRA All indoor units (excluding SLZ-VAL and SEZ-VAL) Heating mode Sound level Dimensions Centralized drain pan 3.6 Application name PEAD-RP100/125 PUHZ-RP250YKM (kW) Compressor output Model name PAC-KE95TB-E PUHZ-RP200YKA2 V: Single-phase, 50Hz, 230V Y: Three-phase, 50Hz, 400V Part name PEAD-RP71 PUHZ-RP170V/YKA2 Power supply Application name PAC-KE94TB-E Air outlet shutter plate External finish Model name PAC-KE93TB-E Air discharge guide Outdoor unit Airflow (cooling/heating) 26 Depth (mm) 330 330 740 Weight (kg) V: 127 Y: 131 136 199 Chargeless piping length (m) 30 30 0 Max. piping length (m) 75 75 75 MA & Contact terminal interface M-NET interface M-NET &Terminal interface Discharge thermo, HP switch Protection device (A) Rated running current (cooling/heating) V: 19.4/23.9 Y: 6.8/8.3 (A) Breaker size 8.2/9.7 V: 40 Y: 32 9.7/11.0 32 32 PEAD-RP, PEA-RP Wireless remote controller signal sender PAR-SL97A-E SEZ-KD, PLA-RP High efficiency filter Rating conditions (AS/NZS 3823) Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB Outdoor: 35°C (95°F) DB Heating - Indoor: 20°C (68°F) DB Outdoor: 7°C (45°F) DB, 6°C (43°F) WB High efficiency filter element PAC-ZC40H-E 50Hz Outdoor Single-phase, 230V Single-phase, 230V/ Three-phase, 400V Guaranteed Operating Range Capacity SUZ-KA35 SUZ-KA PAC-ZC80L-E PAR-SA9CA-E SEZ-KD, PEAD-RP, PEA-RP PAR-SA9FA-E PLA-RP PAC-SH88KF-E PCA-RP50KAQ PAC-SH89KF-E PCA-RP60/71KAQ PAC-SH90KF-E PCA-RP100/125/140KAQ PAC-SH59KF-E PLA-RP 25/35 50 60/71 71/100/125/140/170/200 250 46°C 43°C 46°C 46°C 46°C SUZ-KA60 Upper limit (DB) 24°C 24°C 24°C –5°C (–15°C ) –5°C 21°C 15.5°C (WB) Heating Lower limit (DB) –15°C –15°C –15°C • Sound pressure measurements were conducted in an anechoic chamber. • The actual noise level depends on the distance from the unit and the acoustic environment. PEAD-RP, PEA-RP PAR-SL94B-E PCA-RP Power supply unit PAC-SC50KUA All outdoor units Multiple remote controller adaptor PAC-725AD All indoor units Interface for DRED DRC-101A SUZ-KA • VAD Max. piping length (m) 12 20 12 20 30 30 30 30 –20°C –20°C (WB) SUZ-KA71 PUHZ-RP71 PUHZ-RP100/125/140 30 30 30 30 50 75 With the optional air protection guide, the operation at –15°C outdoor temperature is possible. Sound Pressure Level PAC-ZC01M-E Wireless remote controller kit (Sender & Receiver) Between indoor & outdoor units Cooling –15°C Zone remote controller Max. height difference (m) PUHZ SUZ-KA50 –15°C PEAD-RP, PEA-RP Refrigerant Piping Indoor SUZ-KA25 –10°C PAC-ZC40L-E *1 P series indoor units can be used in combination with SUZ outdoor units. *2 Unable to use with wireless remote controller * For PUHZ-RP250YKM: 7.5m (24ft.) Lower limit (DB) PAC-ZC80H-E Zone controller (Interface & remote controller) Total input based on the indicated voltage (indoor/outdoor) Refrigerant piping length (one-way): 5m (16ft.) Upper limit (DB) SLZ-KA, SEZ-KD, PEAD-RP71*1, PCA-RP50/60/71*1 MAC-333IF-E PAR-FL32MA-E *Above specifications are for outdoor units only. Notes for All Specifications PLA-RP60/71*1 Wireless remote controller Wireless remote controller signal receiver Wired remote controller PUHZ-RP170/200 PUHZ-RP250 30 30 75 75 Pipe size OD (mm) Thickness (mm) Liquid: ø6.35 t 0.8 Gas: ø9.52 t 0.8 Liquid: ø6.35 t 0.8 Gas: ø9.52 t 0.8 Liquid: ø6.35 t 0.8 Gas: ø12.7 t 0.8 Liquid: ø6.35 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø25.4 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø22.2 t 1.0 27 28 Amount of Necessary Refrigerant Amount of Necessar y Refrigerant ( R410A: kg) Factory charged Additional charged Calculation Piping length 7m 10m 15m 20m 25m 30m SUZ-KA25 0.8 0.15 0.3 0.45 — — SUZ-KA35 1.05 0.15 0.3 0.45 — — SUZ-KA50 1.6 0.06 0.16 0.26 0.36 0.46 SUZ-KA60 1.8 0.06 0.16 0.26 0.36 0.46 SUZ-KA71 1.8 0.165 0.44 0.715 0.99 1.265 Xg = 30g/m × (length-5) m Xg = 20g/m × (length-7) m Factory charged Xg = 55g/m × (length-7) m Additional charged Piping length 10 - 30m 31 - 40m 41 - 50m 51 - 60m 61 - 75m PUHZ-RP71 3.5 0.6 1.2 — — PUHZ-RP100/125/140 5.5 0.6 1.2 1.8 2.4 Factory charged Additional charged Piping length PUHZ-RP170/200 10 - 30m 31 - 40m 41 - 50m 51 - 60m 61 - 70m 7.7 0.9 1.8 2.7 3.6 In the Case of PUHZ-RP250YKM Calculation of additional refrigerant charge • Calculate the amount of additional charge based on the length of the piping extension and the size of the refrigerant line. • Use the table below as a guide to calculating the amount of additional charging and charge the system accordingly. • If the calculation results in a fraction of less than 0.1kg, round up to the next 0.1kg. For example, if the result of the calculation was 11.38 kg, round the result up to 11.4 kg. <Additional Charge> NOTICE Liquid pipe size Additional refrigerant charge = Total length of ø9.52×0.06 (kg) Factory Charge: 9 kg (m)×0.06 (kg/m) + 3.0 kg * Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils. Before attempting any installation work you must read the installation instructions. New tools, materials and procedures are required to install these products. Under Australian Law, only persons suitably licensed are permitted to install and service air conditioning units. The buyer must ensure that the person and/or company who is install, service or repair the air conditioner has the necessary licences, qualifications and experience to perform the work. Suitable access for warranty and service is required. Refer to conditions of warranty on the Mitsubishi Electric website. For future improvement, specifications, designs of product and availability are subject to change without notice. Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before installation of these products. Recovery and disposal of waste material must comply with Country, Commonwealth, State or Territory guidelines. * Do not install indoor units in areas (e.g., mobile phone base stations) where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high as this may result in a chemical reaction. * When installing or relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it with any other refrigerant and do not allow air to remain in the lines. If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards. The use of any refrigerant other than that specified for the system will cause mechanical failure or system malfunction or unit breakdown. In the worst case, this may lead to a serious impediment to securing product safety. * Specifications, designs and other content appearing in this brochure are current as at January 2015 and are subject to change without notice. Diagrams are representations for illustrative purposes only. Warm, even heat in winter and cool, comfort in summer is only a phone call or click away. Simply contact your nearest Mitsubishi Electric Specialist today and you can find out all there is to know about how to enhance your living environment. Our specialists are fully qualified to give you all the right advice on which Mitsubishi Electric Air Conditioning System is right for you. To locate your nearest Mitsubishi Electric Specialist go to our website www.MitsubishiElectric.com.au They will determine whether a Compact Inverter System or a Power Inverter System best suits your needs, both in comfort and efficiency. You can either visit one of our Specialist’s Showrooms, or they will happily arrange for one of their Consultants to come to your home. All Mitsubishi Electric Compact and Power Inverter Systems are MEPS (Minimum Energy Performance Standards) Compliant, so you can be sure that they will give you the performance and efficiency that they were designed to deliver. www.MitsubishiElectric.com.au 1300 722 228 Specifications, designs and other content appearing in this brochure are current as at the time of printing and are subject to change without notice. Diagrams are representation for illustrative purposes only. L-179-7-C7654-K 1412 Revised publication, effective March. 2015 Superseding publication L-179-7-C7654-J Jul. 2014 PRINTED: SEPTEMBER 2015
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement