PRESENTATION
Die revolutionary washbasin control
PRODUCT PRESENTATION
The r evolutionar y washbasin contr ol
Product features
High user´s comfort
The active area is around the spout of the tap. It results in a higher
user`s comfort, as water flows immediately, as soon as one reaches
the active area.
Revolutionary sensor-principle
The forward-looking principle of SanTec SKY
works without optical sensor and fits automatically
on the surroundings.
Water savings
2/3 water consumption saving with SanTec SKY
compared to manual taps
Touch Sensor
Touch-sensor for an easy starting of constant water
flow and rinse stop. SanTec SKY disposes of
safety rinse stop and specially tuned and adjustable
rinse programs too.
SanTec SKY
Page 2
PRODUCT PRESENTATION
The r evolutionar y washbasin contr ol
Types and art.no.
SanTec SKY 6V
without mixer
Chromium
art.no. 104 448
SanTec SKY 230V
without mixer
Chromium
art.no. 104 431
SanTec SKY 6V
with mixer
Chromium
art.no. 104 424
SanTec SKY 230V
with mixer
Chromium
art.no. 104 417
Function
Automatic
range setting
on initial start-up,
about 15 secs.
Water flows when
hands come close to
the tap
Water flows as long as hands
are in the active range.
Automatic flushing stop after
60 secs. (adjustable from
30 to 360 secs.)
Hands outside the
active range
Water stops
SanTec SKY
Page 3
PRODUCT PRESENTATION
The r evolutionar y washbasin contr ol
Dimensions in mm
184
Ø 49
165
148
max. 45
112
20°
Ø 33
370
130
Reflusx preventer
with prefilter
Technical specifications
230V mains
operation:
6V battery
operation:
Further details:
Operating voltage:
230V
Power consumption:
approx. 3 VA
Battery:
Lithium 6V
Battery life:
approx. 100.000 flushings (approx. 1,5 years)
Water connection:
G 3/8” inside thread
Active range:
automatic
Flushing:
as long as user is in active area
Flushing stop:
after 60 sec. (30 - 360 sec. adjustable)
Follow-up time:
2 sec. (2 - 15 sec. adjustable)
Flow pressure:
0.5 - 6 bar
Static pressure:
max. 8 bar
Flow rate:
6 l/min.
Noise class:
I
Water temperature:
max. 70° C
SanTec SKY
Page 4
PRODUCT PRESENTATION
The r evolutionar y washbasin contr ol
Installation
1
2
Fix tap on the washbasin
3
Connect to the water supply, use
backflow valve with pre-filter
4
Remove tap cover and insert battery. Fit tap
cover and screw and plug in the 230V power
unit respectively. Turn on the water supply
Automatic range setting. Don`t touch tap
(including valves and flexible pipes) for 15 sec.
5
The tap is ready for use
SanTec SKY
Page 5
PRODUCT PRESENTATION
The r evolutionar y washbasin contr ol
Product layout
Electronic module 6V
art.no. 104 677
Electronic module 230V
art.no. 104 684
Outlet cover
art.no. 104 721
Outlet inner part
art.no. 104 707
Connecting
ring
Magnetic valve 6V
art.no. 231 205
art.no. 104 691
Perlator
art.no. 105 155
Tap lower part incl.
connection hose
mixed water:
art.no. 104 745
3,9X16
Tap lower part incl.
connection hose
cold water:
art.no. 104 752
Reflux preventer
with prefilter
6V Lithium battery
art.no. 232 240
art.no. 230 741
Main supply 30V
art.no. 101 065
SanTec SKY
Page 6
PRODUCT PRESENTATION
The r evolutionar y washbasin contr ol
Electronic module SanTec SKY
3
2
1
1
Via Dip-switch the different flushing programs are adjustable directly on
the electronic module.
2
Controller for the security flushing stop
(adjustable from 30 - 360 s)
30
3
360
Controller for sensitiveness
If the armature stops the water flow during washing hands, you can prevent this by turning right. If the water flows too long after washing hands,
f. ex. longer than 5 sec., this can be reduced by turning left.
SanTec SKY
Page 7
PRODUCT PRESENTATION
The r evolutionar y washbasin contr ol
Position “OFF”:
The water flow starts by touching the tap. The water flows for the adjusted
follow-up time (like self-closing taps).
ON
OFF
1
5
4
Water flows as long as hands are in the water jet. Automatic security flushing
stop after the adjusted flushing stop time. Hands outside the water jet, the
water flow stops after lapse of the adjusted follow-up time.
3
Switch 1 - Function Automatic or manual
Position “ON”:
2
6
Possibilities for adjustments on the dip-switch
Switch 2 - Function cleaning stop
Position “ON”:
Touch the metal outlet before water flows and tip on the “Touch-Sensor” until
the water flow stops. (approx. 5 x in 2 sec.)
The cleaning stop is now activated for 30 s
With every move in the active range the 30 s will begin anew.
Position “OFF”:
No cleaning stop function.
Position of the
Touch-Sensor
Switch 3 - Function continuous flow
Position “ON”:
Activate the water flow and touch immediately for min. 3 secs. the
“Touch-Sensor” of the tap. The water flows for the time, which is adjusted at
the flushing stop controller. By touching the “Touch-Sensor”
anew the continuous flow can be cancelled.
Position “OFF”:
No continuous flow function.
Hygiene flushing active
As soon as the tap was not used for 3 hours, a hygiene flushing will be
released (length see switch 5)
Position “OFF”:
No hygiene flushing
Switch 5 - Function duration of hygiene flushing
Position “ON”:
The hygiene flushing takes 20 s
Position “OFF”:
The hygiene flushing takes 10 s
Switch 6 - Function follow-up time
Position “ON”:
The follow up-time is extended from 3 secs. up to 5 secs.
Position “OFF”:
The follow up-time amounts 3 secs.
These functions can also be combined as desired.
WimTec Elektronische Steuerungs- u. Meßgeräte GmbH
p: A - 3325 Ferschnitz, Freidegg 50
t: (0 74 73) 5000 f: - 500
m: verkauf@wimtec.com
www.wimtec.com
Edition 16 06 2007; Presentation SanTec SKY English
Switch 4 - Function hygiene flushing
Position “ON”: