Vacuum cleaner
FC8724
Philips Domestic Appliances and Personal Care
Service Manual
PRODUCT INFORMATION
ACCESSORIES
- This product meets the requirements regarding
interference suppression on radio and TV.
- After the product has been repaired, it should function
properly and has to meet the safety requirements as
officially laid down at this moment.
- Special nozzle
TECHNICAL INFORMATION
- Accessory storage
-
Colour
Power consumption
Maximum Air displacement
Vacuum
Duststorage capacity
Cord length
Fiter system
- Net weight
:
:
:
:
:
:
:
Oxford Blue
1800 W (IEC) 230 V
33 l/s
250 mbar / 25 kPa
2L
7m
HEPA cyclone-filtration
system
: Permanent motor
protection filter
: HEPA exhaust filter
: 6 kg
Published by Philips Domestic Appliances and Personal Care
07/03
- Nozzle
- Tubes
- Accessories
- Coupling
: Turbo Brush nozzle and
Super Parquet nozzle
: Tri-Active all purpose nozzle
: Metal lacquered telescopic tubes
: Brush, crevice nozzle and small
nozzle
: Active accessory storage bridge in
handgrip
: Button coupling
OPTIONAL (accessories)
- FC8047 Filter Cylinder + Motor inlet Filter
Printed in the Netherlands
© Copyright reserved
Subject to modification
FC8724
DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- To open the appliance, first remove the filter cover
(item 17).
- Remove the dust bucket including filter.
- Remove the turn plate cover (item 6) after removing the
2 screws (A).
- Remove the 6 screws (B) at the bottom of the appliance.
For 2 screws a screwdriver with a 14.5 cm long shrank is
required. Screwdriver 4322 009 08490 for T15 is suitable
for this.
- Lift the upper housing by pulling only the middle of the
backside up (use a screwdriver if necessary).
Further disassembly advise for the potmeter:
- Remove the turn knob by just pulling it (use a screwdriver
if necessary).
- Remove the 2 screws (C) inside the upper housing, use
TORX screwdriver no. T10, which is one of a set consisting
of T20; T15; T10; T9; T8; T7 and T6 (code number
4822 395 505145).
REPAIR INSTRUCTION
- The cord winder spring must be tensioned to the maximum
level and then be rewound approx 1.5 turns.
- Item 22, air valve, opens to cool the motor if the air
displacement is too low or if the airflow is blocked.
- Both item 22, air valve, and item 23, inlet tube B, must be
replaced in appliances produced before WK626. This to
prevent/solve premature and noisy opening of the valve.
- If the function of the electronic control unit is not required,
the Triac must be short-circuited in the manner shown in
the circuit diagram.
- Filter performance can be improved (less reduction of
suction power in time) replacing both Filter assy (pos. 25)
and Bucket cover assy (pos. 26) by using “improved filter
service kit” 4322 009 09790 (pos. 61).
- Separate “long Filters” are available under code
4322 004 93320 (pos. 60)
- Remove the potmeter connector from the printed circuit
board.
- Do not forget to reconnect the potmeter when re-assembling the upper housing (connector fits in one way only).
- When the repair is finished, check whether all functions of
the appliance work properly.
ELECTRICAL DIAGRAM
Potmeter
Cordwinder
Red
White
Blue
M
Switch
Blue
White
Motor Power Module
Shortcircuit
= changed
Triac
2-7
PARTS LIST
Pos
Service code
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
19
20
21
22
23
24
25
26
27
28
29
30
9965 000 33690
9965 000 33731
9965 000 33692
4322 004 20130
9965 000 33693
9965 000 33732
9965 000 33695
9965 000 33696
9965 000 33697
9965 000 33698
9965 000 33699
4322 004 93310
9965 000 33700
9965 000 33701
9965 000 33702
9965 000 33703
9965 000 33733
8838 044 01010
9965 000 33706
9965 000 33707
4322 005 19110
9965 000 33708
9965 000 27741
4322 004 93300
9965 000 33734
9965 000 33735
9965 000 33711
4322 009 09420
4322 005 17910
FC8724
Description
Pos
Service code
Turn knob
Upper housing assy Oxford Blue
Potmeter kit
Filter cleaning brush
Turnplate
Turnplate cover
Oxford Blue
Turnplate lever
PCB Assy
Air inlet tube A
Motor cover B
Air Inlet Sealing
Air Inlet Filter
Motor cover B buffer ring
Motor Cover A
Dustbucket support
Motorcover A bufferring
Backgrille assy
Oxford Blue
Hepa Filter
Cooling tube
Safety valve cover
Safety valve assy
Air inlet tube B
Switch
Filter assy
Bucket cover assy
Oxford Blue
Dustbucket assy
Oxford Blue
Cordwinder cover
Cordwinder assy (no cordset)
Contactplate ass’y
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
9965 000 27730
9965 000 33712
4322 000 38820
4322 001 73450
9965 000 33713
4322 001 73440
4322 003 26030
4322 009 09400
9965 000 33714
4322 006 01410
4322 006 01670
4322 006 01680
4322 006 07470
4322 003 25510
4322 005 19130
4322 007 16000
4322 003 25560
4322 005 17590
4341 004 20510
4822 532 60688
4822 492 62163
4322 004 23280
4322 004 23260
9965 000 33715
4341 004 20490
4322 005 11040
8838 041 01010
4322 004 23250
4322 004 22960
4322 004 93320
4322 009 09790
9965 000 45369
Description
Caster assy
Cord outlet
Silencer A
Buffer Back
Silencer B
Motor buffer front
Bracket
Domel service kit
Lower Housing
Cordset Euro 4.8 pin L = 9.3 m
Cordset Swiss
L = 9.3 m
Cordset Taiwan
L = 6.3 m
Cordset UK/HK
L = 7.3 m
Curve Bend B1
Curve Bend B1/Hose assy
Leafspring
Crevice Nozzle
Accesoire bridge assy
Plumeau assy
Tube bush
Tube spring
Telescopic tube
Tri-Active Nozzle stand
Tap turn assy
Small Nozzle
Polishing disc
Polishing brushes
Super parquet Nozzle
Turbo Nozzle
Improved Filter
Improved Filter service kit *
Silencer C
* Standardized grey colour.
= changed
3-7
EXPLODED VIEW
FC8724
1
17
2
19
3
C
2x
20
21
22
8
9
4
23
10
24
5
11
12
6
7
A
A
13
14
15
16
4-7
EXPLODED VIEW
FC8724
25
26
60
61
27
40 ÷ 43
35
36
28
32
38
33
37
34
29
62
39
30
B
6x
31
5-7
EXPLODED VIEW
FC8724
Europe
40
Taiwan.
42
Swiss
41
U.K. / H.K.
43
45
44
54
49
47
48
55
46
50
52
51
53
56
58
57
6-7
EXPLODED VIEW
FC8724
7-7
Download PDF
Similar pages