ALED 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the
construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING ARM ON FIXTURE
1. Remove the Arm Cover from the Arm.
2. Feed wires from Fixture through Gasket into Arm.
3. Line up Arm and Fixture. Place flat washers, lock washers
and nuts on the Short 3/8-16 bolts inside the Arm and
tighten securely to housing.
4.Make sure the Gasket is secure between Arm and
Fixture.
Fixture
Gasket
Arm
MOUNTING FIXTURE
DIRECTLY TO POLE
Check that pole is drilled according to Pole Drawing Detail.
1.Remove the Arm Cover from the Arm.
2.Feed wires from Fixture through Gasket into Arm. Feed
supply wires from Pole through Gasket into Arm.
3.Insert Long 3/8-16 bolts through Arm, Gasket, Pole
and thread into the Bolster Plate. Be sure the Gasket
is between the Arm and pole and secure with bolts,
washers and lockwashers.
4.Make necessary connections inside the Arm and knot
wires for strain relief.
5.Replace the Arm Cover. Be sure the Gasket on Arm
Cover is in place. Tighten Screws and add the Plugs.
Secure Pole cap.
Gaskets (2)
Arm
Plugs
short 3/8”
bolts
Screws
Arm Cover
Plugs
Screws
Long 3/8” bolts
Arm Cover
Short 3/8” bolts
Pole Cap
Bolster
Plate
®
ALED 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
ROUND POLE ADAPTOR
ACCESSORY
ON-OFF WIRING
For use with standard RAB pole drilling.
1. Drill round pole using the dimensions shown in the Pole
Drilling Detail.
2. Place Round Pole Adaptor (RPA) and RPA Gasket
between the fixture and drilled Pole as shown.
3. Line up top holes of the Gaskets and Round Pole
Adaptor with top hole in the pole drilling pattern.
4. Place long 3/8” Bolts from the ALED thru the top hole
of the RPA and Gaskets to the Round Pole thread into
Bolster Plate.
5. Feed wires from Fixture through Gasket into Arm. Feed
supply wires from Pole through Gasket into Arm. Make
necessary connections inside the Arm and knot wires for
strain relief.
6. Replace the Arm Cover, tighten Screws and add the
Plugs. Secure Pole cap.
Long 3/8” Bolts
Round Pole Adaptor (RPA)
Arm Gasket
Plugs
Screws
Arm Cover
RPA Gasket
Bolster Plate
Round Pole
(not supplied)
PHOTOCELL INSTALLATION
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
BLACK
PHOTOCELL
PHOTOCELL
(+)LINE
BLACK
(-)COMMON
WHITE
GROUND
LIGHT
FIXTURE
GROUND
Fig. 1
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. For 0-10V Dimming, follow the wiring directions
as in fig. 2.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to
the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.
Fig. 2
Photocell may be installed in the field. Apply weatherproof
silicone sealant to all plugs and unused conduit entries.
“COM”
WHITE
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. Units ordered with (/480V) suffix are 480V, 60Hz.
For Non-Dimming, follow the wiring directions as in fig. 1.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply ground.
LIGHT
WP2FC
FIXTURE
®
ALED 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
POLE DRILLING DETAIL
CLEANING & MAINTENANCE
For non-RAB poles use these dimensions to drill the pole.
This template is not to scale. Please use measurements
shown.
CAUTION: Be sure fixture temperature is cool enough
to touch. Do not clean or maintain while fixture is
energized.
1. Clean glass lens with non-abrasive glass cleaning
solution.
2. Do not open fixture to clean the LED. Do not touch the
LED.
TROUBLESHOOTING
1. Check that the line voltage at the fixture is correct. Refer
to wiring directions.
2. Be sure the fixture is grounded properly.
3. Is the photocell, if used, functioning properly?
Patent: US: pat. D668,370
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.
Easy Installation & Product Help
©2013 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
ALED IN 1113
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
TM
ALED SLIPFITTER 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING FIXTURE
1. The Slipfitter fits a 2 3/8” O.D. Tenon. Place the slipfitter
over the tenon and secure the fixture with 2 Set Screws
on the side of the slipfitter.
Fixture
Slipfitter
2. Feed wires from Fixture through slipfitter and supply
wires from Pole. Make the necessary connections in the
slipfitter and knot wires for strain relief.
3. To adjust the angle of the slipfitter, remove 2 screws and
remove the Slipfitter Cover Plate. Loosen the Locking
Bolt and swivel fixture to desired angle. The graduation
on the slipfitter cover plate can be used as guidelines to
adjust the angle.
4. Tighten the Locking Bolt. Replace slipfitter cover plate.
Tighten Screws and close the Plug.
5. Seal Plug using Teflon tape or silicone sealant.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough
to touch. Do not clean or maintain while fixture is
energized.
1. Clean glass lens with non-abrasive glass cleaning
solution.
2. Do not open fixture to clean the LED. Do not touch the
LED.
Locking Bolt
Set
screws
Plug
Screws
Slipfitter
cover
plate
Tenon
TROUBLESHOOTING
1. Check that the line voltage at fixture is correct. Refer to
wiring directions.
2. Is the fixture grounded properly?
3. Is the photocell functioning properly (if used)?
TM
ALED SLIPFITTER 50W 78W 105W 125W 150W INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
ON-OFF WIRING
0-10V DIMMABLE WIRING
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. Units ordered with (/480V) suffix are 480V, 60Hz.
For Non-Dimming, follow the wiring directions as in fig. 1.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply ground.
Universal voltage driver permits operation at 120V thru 277V,
50 or 60 Hz. For 0-10V Dimming, follow the wiring directions
as in fig. 2.
1. Connect the black fixture lead to the (+) LINE supply lead.
2. Connect the white fixture lead to the (-) COMMON supply
lead.
3. Connect the GROUND wire from fixture to supply ground.
Do NOT connect the GROUND of the dimming fixture to
the output.
4. Connect the purple fixture lead to the (V+) DIM lead.
5. Connect the gray fixture lead to the (V-) DIM lead.
6. Cap the yellow fixture lead, if present. Do NOT connect.
(+)LINE
BLACK
(-)COMMON
WHITE
GROUND
LIGHT
FIXTURE
Fig. 1
GROUND
PHOTOCELL INSTALLATION
Photocell may be installed in the field. Apply weatherproof
silicone sealant to all plugs and unused conduit entries.
Fig. 2
1. Remove close up plug on top of the wall mounting box.
2. Install photocell and wire as per diagram.
3. Use photocell rated for your supply voltage.
BLACK
“COM”
WHITE
LIGHT
WP2FC
FIXTURE
PHOTOCELL
PHOTOCELL
RAB fixture designs are protected under U.S. and International Intellectual Property laws.
Patents: US: pat. D587,839; CN: ZL200830272893.0; MX: 28396, TW: pat. 96304793-U02; CA: D RAB Lighting, Inc
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.
Easy Installation & Product Help
©2013 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
ALEDSF IN 0114
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
®
®
ALED3T & WPLED3T BILEVEL INSTRUCTIONS
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the
construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING ARM ON FIXTURE
1. Bi-level fixtures have LED’s wired in sets. The two sets are shown below.
2. Each set has leads brought through the arm and labeled.
3. Use the sets for switching as needed in your application.
Set #1
Set#2
Easy Installation & Product Help
©2013 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
Page 1
email
Answered promptly sales@rabweb.com
®
®
ALED WPLED ARM WITH WATTSTOPPER SENSOR
Thank you for buying RAB lighting fixtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fixtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. This product must be installed in accordance with the applicable installation code by a person familiar with the
construction and operation of the product and the hazards involved.
WARNING: Make certain power is OFF before installing or maintaining fixture. No user serviceable parts inside.
MOUNTING ARM ON FIXTURE
1. Loosen bolts and remove Arm, if exists.
2. Remove the Arm Cover from the Arm.
3. Feed wires from Fixture through Gasket into Arm.
3. Line up Arm and Fixture. Place flat washers, lock washers
and nuts on the Short 3/8-16 bolts inside the Arm and
tighten securely to Fixture.
WARNING: Orient Arm with Wattstopper Sensor
facing down.
4.Make sure the Gasket is secure between Arm and
Fixture.
5. Connect wires as shown in wiring diagram. Use
appropriate UL approved wire connectors as required
by code to complete wiring in Arm with Wattstopper
Sensor and supply wires. Push all wires back into the
Arm. Be careful not to pinch wires.
WARNING: To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other
sharp objects.
6. Follow directions on ALED/ WPLED instruction sheet to
secure the fixture to a pole or wall.
Fixture
0-10V DIMMABLE WIRING WITH
WATTSTOPPER SENSOR
Universal voltage driver and Wattstopper Sensor permits
operation at 120V thru 277V, 50 or 60 Hz. For 0-10V Dimming
with Wattstopper, follow the wiring directions.
1. Connect the black fixture lead to the LOAD of Wattstopper
Sensor.
2. Connect LINE of Wattstopper Sensor to LINE supply lead.
3. Connect the white fixture lead and NEUTRAL of
Wattstopper Sensor to the COMMON supply lead.
4. Connect the GROUND wire from fixture and Wattstopper
Sensor to supply ground. Do NOT connect the GROUND
of the dimming fixture to the output.
5. Connect the purple fixture lead to DIM + of Wattstopper
Sensor.
6. Connect the gray fixture lead to the DIM - of Wattstopper
Sensor lead.
7. Cap the yellow fixture lead, if present. Do NOT connect.
Gasket
Arm
Plugs
Screws
Short 3/8”
Long 3/8”
bolts
bolts
Arm Cover
Wattstopper
Sensor
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during
installation, operation or maintenance.
Easy Installation & Product Help
©2015 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
ALED WPLED WS IN 1015
Tech Help Line
Call our experts 888 RAB-1000
rabweb.com
Visit our website for product info
email