VPX56-6 6U VPX AC/DC Power Supply 700

VPX56-6
700-Watt AC/DC Power Supply
VPX56-6 6U VPX AC/DC Power Supply
700-Watt Ruggedized, Programmable Power Supply
Plug-in Module, Conduction-Cooled, Six Outputs
Description
NAI’s VPX56-6 is a 700-Watt AC/DC Power Supply that plugs directly into a standard 6U VPX chassis with a VITA 62 1.0” power supply
slot. This off-the-shelf solution for VITA 46.0 and VITA 65 systems is compatible with VPX specifications; supports all VITA standard I/O,
signals, and features; and conforms to the VITA 62 mechanical and electrical requirements for modular power supplies.
The VPX56-6 programmable power supply is conduction-cooled through the card edge/wedgelock. It accepts 3Ø AC or +270 VDC input and
provides six outputs and I/O at up to 700 Watts.
The VPX56-6 supports a variety of standard features, including continuous Background Built-in-Test (BIT); remote error sensing; holdup
time; and protection against transients, over-voltage, over-current, and short circuits. With its intelligent design, the VPX56-6 also has the
flexibility to address special needs. Options include current share and alignment keys for input and output configurations.
This COTS power supply is specifically designed with NAVMAT component derating for rugged defense and industrial applications. It is also
designed to meet the many harsh environmental requirements of military applications.
Features
















VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
Ideal for rugged 6U VPX power applications
Standard VPX-compatible connectors and I/O per VITA 62
Compatible with System Management Bus per VITA 46.11
Off-the-shelf solution for VITA 46.0 and VITA 65 systems
Supports all VITA standard I/O, signals, and features
Accepts 3Ø AC or +270 VDC input
Provides six outputs and I/O at up to 700 Watts
Continuous Background Built-in-Test (BIT)
User Programmability
Current share
Status LED
Alignment keys per VITA 62
Input transient protection per MIL-STD-704F
Integrated EMI filtering per MIL-STD-461F
Environmentals per MIL-STD-810G and VITA 47
Operates at full load through the entire -40°C to +85°C temperature range
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 1
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Electrical Specifications
AC Input Characteristics
Input
Accepts 115 VAC, Three Phase AC, or 270 VDC (see Input Pinout Designations Table, page 5 and
Ordering Information, page 9)
Input Voltage Range
±10%
Frequency Range
47 Hz to 440 Hz
EMI/RFI
MIL-STD-461F – CE102, CS101, CS114 a & b, CS116 (At the system level, additional filtering may
be required due to backplane design and characteristics or system components). Refer to Typical
EMI scan with static load on Page 11.
Input Transient Protection
Per MIL-STD-704F
DC Output Characteristics
Output Power
700 Watts typical at 85ºC (see Output Power Table, including notes, page 3)
Output Voltage
VPX outputs standard (see Output Power Table, page3)
Efficiency
88% typical
Line Regulation
Within 0.5% or 20 mV (whichever is greater) for low to high line changes at constant load;
For current share units: 1.5% for VS1, VS2, VS3; 2% for +3.3 VDC_Aux; 2% for +12 VDC_Aux
Load Regulation
0.5% or 20 mV (whichever is greater) for 0 to 100% of rated load at nominal input line;
With remote sense: 1% for -12 VDC_Aux , +12 VDC_Aux;
For current share units: 1.5% for VS1, VS2, VS3, +3.3 VDC_Aux; 2% for +12 VDC_Aux
PARD (Noise and Ripple)
50 mV p-p max per VITA 62; measurements are made with a 20 MHz bandwidth instrument
connected on load wires < 5 inches from power supply and terminated with 1uF capacitors across
load lines
Load Transient Recovery
Output voltage returns to regulation limits within 0.5 msec, half to full load
Load Transient Under/Overshoot
5% of nominal output voltage set point (1.4 V max)
Short Circuit Protection
Protected for continuous short circuit with automatic recovery
Current Limiting
All outputs 105% to 130%
Over Voltage Protection
Automatic electronic shutdown if outputs exceed 125% 10%
Holdup Time
With external capacitors (pins provided on unit I/O connector)
Remote Error Sensing
Sensing pins compensate for up to 0.5 V drop on VS1 to VS3 outputs
Isolation Voltage
1000 VDC input to output and input to case; 100 VDC output to case
Insulation Resistance
50 Mega Ohm at 50 VDC
All specifications are subject to change without notice.
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 2
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Additional Specifications
Physical/Environmental
Temperature Range
Operating: -40C to +85C at 100% load (temperature measured at card edge, conduction via card edge);
Storage: -55C to +105C per VITA 47 CC4)
Temperature Coefficient
0.01% per C
Shock
30 G’s each axis per MIL-STD-810G, Method 516.6, Procedure 1;
Hammer shock per MIL-S 901; ½ sine wave per VITA 47 OS2
Acceleration
6 G’s per MIL-STD-810G, Method 513.6, Procedure II; 14 G’s per Procedure 1
Vibration
Per MIL-STD-810G, Method 514.6, Procedure 1
Humidity
95% at 71C per MIL-STD-810G, Method 507.5 (non-condensing)
Altitude
1,500 feet to +60,000 feet per VITA 47
Sand/Dust
Per MIL-STD-810G, Method 510.5
Fungus
Per MIL-STD-810G, Method 508.6
ESD
15kV EN61000-4-2 per VITA 47
Enclosure
Aluminum housing to aluminum baseplate
Dimensions
See Mechanical Layout
Finish
Chemical film IAW MIL-DTL-5541 Type II, Class 3
Interface
See Connector Specifications below
Weight
3.85 lbs. typical
All specifications are subject to change without notice.
Output Power
Connector Specifications
Designation
Volts
Amps
Unit Connector
Backplane Connector (Mate)
VS1/VS2
+12.0
30 (Total)**
Input
P0: 6450843-6
J0: 6450863-5
VS3
+5.0
50
Output
P1: 6450849-6
J1: 1-6450869-0
3.3 V_Aux
+3.3
20
+12_Aux
+12
3
-12_Aux
-12
3
*Total output power limited to 700 Watts.
**VS1 and VS2 are combined into one output.
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 3
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Signal Types
Signal
Description
ENABLE*
Turns off all of the output voltages, including 3.3 V_AUX, when signal is High. ENABLE* is pulled Low by using a
mechanical switch which connects it to SIGNAL_RETURN. A Logic output can also be used to drive the ENABLE*.
Opening the switch would turn off all the outputs; closing the switch or applying the Logic output would enable the
outputs to come on depending on the state of INHIBIT*. An input of <0.8 VDC is regarded as a Low and an input of
>2.0 VDC is regarded as a High. A no-connect is also regarded as a High. Along with INHIBIT*, this signal
determines the output power status of the VPX56-6 (see Power Status Table, page 5).
INHIBIT*
Turns off all the output voltages. In most implementations, the signal is expected to leave 3.3 V_AUX on. Pulling
INHIBIT* Low turns off VS1, VS2, VS3, and ±12 VDC_Aux outputs. An input of <0.8 VDC is regarded as a Low and
an input of >2.0 VDC is regarded as a High. A no-connect is also regarded as a High. Along with ENABLE*, this
signal determines the output power status of the VPX56-6 (see Power Status Table, page 5).
SYSRESET*
An active low open-collector line driven by the Power Monitor module. Signal ensures a clean, stabilized startup
based on monitoring the output voltage levels in accordance with VITA 46.0, paragraph 4.8.11. Timing can be
factory customized.
FAIL*
Indicates failure when any of the outputs are not within specification. Signal complies with VITA 65 for active Low.
FAIL* signal is Open Drain. It is expected that there will be a pull-up resistor on the backplane.
Geographical
Addressing
As defined in VITA 46
Current Share
Allows multiple power supplies to share system load for VS1, VS2, and VS3 outputs. Connection is made per
designated pins for each output.
Protocol
Per VITA 46.11 System Management Bus
Status LED
See LED Status table below
LED Status
LED State
Meaning
Off
Input Low
Green (Steady)
Vout OK; All outputs are good
Red (Steady)
Fail; Follows same logic as FAIL* signal
Blinking Green
Unit disabled
Blinking Red
Over Voltage or Over Temperature ( all outputs are off)
Power Status
Control Input States
Power Output States
ENABLE*
INHIBIT*
+3.3V_AUX
VS1, VS2, VS3,
+12V_Aux & -12V_Aux
High
High
Off
Off
High
Low
Off
Off
Low
High
On
On
Low
Low
On
Off
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 4
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
I2C Communication
1.
Hardware Interface.
Electrical interface is based on I2C parameters at 100 kHz. The backplane or I2C master controller should provide pull up resistors on SDA
and SCL lines to a 3.3V rail.
2.
Address.
The I2C Hardware Address (per VITA 46.11 Rev 0.15) is 7 bits. The default base address is 0x20. *GA0 through *GA4 provide the 5 LSB’s
for the address.
The *GA pins have 3.32K pull‐up resistors to a 3.3V rail. The resistors and the 3.3V rail are internal to the power supply. When left open, the
address will be 0x20, otherwise, the address will be as described in the table below.
Signal
*GAP
*GA4
*GA3
*GA2
*GA1
*GA0
Pin A5
Pin B5
Pin A4
Pin B4
Pin C4
Pin D4
Gnd
High
High
High
High
High
0x20
High
High
High
High
High
Gnd
0x21
High
High
High
High
Gnd
High
0x22
Gnd
High
High
High
Gnd
Gnd
0x23
High
High
High
Gnd
High
High
0x24
Gnd
High
High
Gnd
High
Gnd
0x25
Gnd
High
High
Gnd
Gnd
High
0x26
High
High
High
Gnd
Gnd
Gnd
0x27
I2C
Address
If the unit detects an error on the *GAP input setting, it will respond to address 0x20.
3.
Data Read - Get Sensor Reading results
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 5
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Request Data
Response Data
Byte
Data Field
Data
1
cmd
See table
2 to n-1
Data If Required by cmd or Zero ChkSum* if no Data required.
n
Zero ChkSum* if Data was required by cmd
1
Completion Code – Echo cmd Number
2 to n-1
Per cmd Response
n
Zero ChkSum
*Note : Slave address should not be included in Zero Checksum calculation.
4. Commands
Sensor #
Name
Description
21H
Composite Sensor
64 bytes of scanned sensor data. Data is continually scanned and
available for report. Data consists of 2 bytes of data for each of the 11
sensors and FRU data.
55H
Status Write Command
Writes Status byte on Composite Sensor.
44H
Firmware release date
22 byte response. Month/Day/Year Hr/Min/Sec in ASCII form.
45H
Hardware Address
3 byte response. Reports address set by GA0*-GA4*
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 6
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
4.1 Composite Sensor Read Command – 21H
Response
Data Type
Meaning
Completion Code – 21h
Status Register 0, MS Bit First
Signed Integer, MSB First
U Integer, MSB First
Echo of the command
Refer to table below
Temperature as follows °C = (Reading * 100 / 16384)
Voltage on VS1, 12V = 16384
Reserved
Voltage on VS3, 5V = 16384
Voltage on 3.3Aux, 3.3V = 16384
Voltage on +12V Aux, 12V = 16384
Absolute Voltage on -12V Aux, 12V = 16384
Current on VS1, 30A = 16384
Reserved
Current on VS3, 50A = 16384
Current on 3.3Aux, 20A = 16384
Current on +12VAux, 3A = 16384
Absolute Current on -12VAux, 3A = 16384
Internal Reference, 2.5V = 16384
Reserved
Part Number
S/N Hi
S/N Low
Date Code (Year/Week)
Hardware Rev
Firmware Rev.
Reserved
Value required to make the sum of bytes 0 to 62 add to a multiple of 256 (decimal).
BYTE #
0
1
2-3
4-5
6-7
8-9
10-11
12-13
14-15
16-17
18-19
20-21
22-23
24-25
26-27
28-29
30-31
32-51
52-53
54-55
56-57
58-59
60-61
62
63
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
Character String
U Integer, MSB First
U Integer, MSB First
U Integer, MSB First
Character String
Character String
Reserved
Zero Checksum
Status Reg 0
Bit
R/Set
R/Set
R/W
R/W
R/W
R
R
7
6
5
4
3
2
1
0
x
FAIL
OTWarning
SWPriority
*SW Inh
*SW En
*HW Inh
*HW En
Bits 5 AND 6 (OTWarning - FAIL) are Read and write. They are clear at startup. User can set them with a Status Write command. Hardware
will clear them if there is a fault.
Bit 4 (SWPriority) is Read and write. It is clear at Startup. When clear the unit will be controlled by the hardware enable and inhibit signals.
When set, the unit will be controlled by the SW inhibit and enable signals.
Bits 3 and 2
(SWInh SWEn ) are read and write. Their logic works the same as the logic for the hardware Enable and Inhibit.
*SWEnable
*SWInhibit
OUTPUTS
0
0
INHIBIT (3.3V Aux is On, all other outputs are off)
0
1
ON
1
0
OFF
1
1
OFF
Bits 1 and 0 (HWIn - HWEn) are read only. They show the state of *Enable and *Inhibit pins while SWPriority is low.
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 7
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
4.2 Status Write Command - 55H
BYTE #
Data Type
Meaning
U Character – 55H
0
Command
1
U Character
Data
2
Zero Checksum
Value required to make the sum of bytes 0 and 1 add to a multiple of 256 (decimal).
The command to write to Status byte is 55h, followed by 8-bit data then zero checksum.
Example: To send a command to clear the faults and turn on all the outputs, the following sequence must be sent.
55h 78h 33h;
55h is the command needed to write to status byte zero.
78h data for byte zero,
Bit 7 set: don’t care bit.
Bit 6 set: FAIL signal is high, software will clear it if unit fails
Bit 5 set: OTWarning signal is high, software will clear it if unit is close to 75 degrees.
Bit 4 set: Software has priority to enable/disable unit.
bit 3 set: SWInhibit is high
bit 2 low: SWEnable is low.
33h Value to achieve a sum of zero.
4.3 Firmware release date – 44H
Response
Data Type
Meaning
0
Completion Code – 44H
Echo of the command
1-20
Character String
Date
21
Zero Checksum
Value required to make the sum of bytes 0 to 20 add to a multiple of 256 (decimal).
BYTE #
4.4 Hardware Address – 45H
Response
Data Type
Meaning
0
Completion Code – 45H
Echo of the command
1
U Character
I2C Hardware Address
2
Zero Checksum
Value required to make the sum of bytes 0 and 1 add to a multiple of 256 (decimal).
BYTE #
Input Pinout Designations (P0)
Pin #
Rated Current (A)
Name
Description
P7
40
ACL/L1 (+270 VDC)
AC Phase 1 or +270 VDC input
P6
40
L2
AC Phase 2
P5
40
L3
AC Phase 3 or +270 VDC Return
P4
40
ACN
AC Neutral
P3
40
N/U
Not Used
P2
40
N/U
Not Used
P1
40
CHASSIS
Chassis Ground
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 8
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Output Pinout Designations (P1)
Pin
#
Rated
Current
(A)
Pin Name
Pin #
Rated
Current
(A)
Pin Name
P10
40
VS1/VS2
VS1/VS2 combined
into one output
D5
<1A
SM1
System Management
Bus (I2C Data)
P9
40
VS1/VS2
VS1/VS2 combined
into one output
A4
<1A
GA3*
Geog. Address
A9
<1A
VS1/VS2_SENSE
Remote Sense for
VS1/VS2
B4
<1A
GA2*
Geog. Address
B9
<1A
RESERVED
C4
<1A
GA1*
Geog. Address
C9
<1A
VS3_SENSE
Remote Sense for VS3
D4
<1A
GA0*
Geog. Address
D9
<1A
UD0
User Defined
A3
<1A
+12V_AUX
+12 VDC_Aux Output
A8
<1A
VS1_SENSE_RTN
Remote Sense Return
B3
<1A
+12V_AUX
+12 VDC_Aux Output
B8
<1A
RESERVED
C3
<1A
RESERVED
C8
<1A
VS3_SENSE_RTN
Remote Sense Return
for VS3
D3
<1A
RESERVED
D8
<1A
UD1
User Defined
P6
40
VS3
VS3 Output
A7
<1A
VS1/VS2_SHARE
Current Share for
VS1/VS2
P5
40
VS3
VS3 Output
B7
<1A
+3.3_Aux Share
Used only on option
codes with Aux Share
P4
40
POWER_RETURN
Common Output Return
C7
<1A
VS3_SHARE
Current Share for VS3
P3
40
POWER_RETURN
Common Output Return
D7
<1A
SIGNAL_RETURN
Common Signal
Return
A2
<1A
VBAT
Connected Internally to
+3.3 VDC_Aux
P8
40
POWER_RETURN
Common Output
Return
B2
<1A
FAIL*
Active Low Open-Drain
P7
40
POWER_RETURN
Common Output
Return
C2
<1A
INHIBIT*
Used with ENABLE*
(see Power Status
Table, page 5)
A6
<1A
SM2
System Management
Bus
D2
<1A
ENABLE*
Used with INHIBIT*
(see Power Status
Table, page 5)
B6
<1A
SM3
System Management
Bus
A1
<1A
UD3 or
SMB_Alert
User Defined
SMB_Alert used on
option code 04
C6
<1A
-12V_AUX
-12 VDC_Aux Output
B1
<1A
-12V_AUX
-12 VDC_Aux Output
D6
<1A
SYSRESET*
System Reset (Active
low open-collector)
C1
<1A
UD5 / +3.3_Aux
Sense
User Defined; +3.3_Aux
A5
<1A
GAP*
Geographical Address
(Parity)
D1
<1A
UD6 / +3.3_Aux
Sense Rtn
User Defined; +3.3_Aux
B5
<1A
GA4*
Geographical Address
P2
40
3.3V_AUX
C5
<1A
SM0
System Management
Bus (I2C Clock)
P1
40
POWER_RETURN
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
Description
VPX56-6A001 Rev. F
Tel: 631.567.1100
Description
+3.3 VDC_Aux Output
Common Output Return
Page 9
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
VPX56-6 Connections
RESERVED PINS
P2 Output
B8
C3
B9
D3
P0 Input
P2
P3
To Signal Return
(as required by system)
GA0* through GA4* & GAP* Lines each connected like this
Chassis
P1
P9, P10
AC Neutral
P4
A9
AC Phase 3
or +270Vdc_RTN
P5
AC Phase 2
P6
+3.3 Internal
AC Phase 1
or +270Vdc Input
Input
Connector
A8, C8
P1, P3, P4,P7, P8
C9
A8, C8
I2C Clock
and Data
SM1 (Data)
D5
SM2
A6
SM3
B6
P1, P3, P4,P7, P8
B1 C6
P1, P3, P4,P7, P8
INHIBIT*
C2
ENABLE*
D2
Pwr_Return
Pins A8, B8, C8 are common
return for VS1 to VS3 Sense.
VS3
Pins P1, P3, P4,P7, P8
are common returns for all
Power outputs
VS3_Sense
L
O
A
D
D7 is common return for all
signals
Pwr_Return
A3 B3
Refer to Table
# 2; Power
Status
Sense_Return
Sense_Return
P1, P3, P4,P7, P8
C5
L
O
A
D
VS1/VS2_Sense
P5, P6
P7
SM0 (Clock)
VS1/VS2
Plus 12_Aux
Pwr_Return
Minus 12_Aux
Pwr_Return
P2
+3.3_Aux
P4, P5
Pwr_Return
L
O
A
D
L
O
A
D
Current Share
Example
Additional NAI
VPX56
Current Shared
L
O
A
D
A7
VS1/VS2_SHARE
A7
C7
VS3_SHARE
C7
B7
+3.3_Aux_SHARE
(Optional)
B7
D7
Signal Return
all Signals
D7
Optional
UD0
D9
UD1
D8
UD2
A1
UD4
C1
UD6
D1
B2
A2
D6
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
FAIL*
1K
+3.3_Aux
VBAT
SYSRESET
(To VPX Backplane)
Page 10
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Typical EMI Scan with Static Load and No Additional Filtering
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 11
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Mechanical Layout
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 12
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Ordering Information
VPX56 - Form Pitch RSV
Battery
Current
Share
Input Voltage
Align Key 1 *
Input Type
Align Key 2 *
Output Config
Align Key 3 *
- Opt Code
See Code
Table
Key Position /
Output
A = 0° (Std)
B = 45° (Reserved)
C = 90° (Reserved)
D = 270° (Reserved)
E = 315° (Reserved for 03 opt code)
Key Position /
Input Voltage Value
A = 0° (18V-36V)
B = 45° (0V-18V)
C = 90° (36V-85V)
D = 270° (85V to 265V)
E = 315° (265V-500V)
A = Not Installed
B = Installed
Key Position /
Input Type
A = 0° (DC)
B = 45° (1 Phase)
C = 90° (3 Phase)
D = 270° (Reserved)
E = 315° (Reserved)
Refer to Mechanical Outline Drawing for
location of Alignment keys 1, 2 & 3
A = No Battery
B = Connected Internally to
+3.3vdc Aux
A = Reserved
1 = 1.0"
6 = 6U
Series 56 = VPX AC/DC
* Note:
Per VITA 62, all 6U power supplies must use three alignment keys, numbered 1 through 3. These keys are used as part of the
VPX56-6 part number and indicate both the input and output configuration of the unit being ordered.
Key 1 = Input Voltage Range
Key 2 = Input Voltage Type; DC, 1Ø AC or 3Ø AC
Key 3 = Output Configuration
Example Part Number: VPX56-61AABDCA-00
Equals VPX Power supply AC/DC, 6U. 1.0" pitch, no internal battery, current share on VS1, VS2 and VS3, Input Voltage 85V to 265V,
3 Phase AC input, Std VPX Outputs, no additional options
VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 13
www.naii.com
VPX56-6
700-Watt AC/DC Power Supply
Option Code Table
Code
00
Description

Standard Unit, no additional options
VS1/VS2 = +12Vdc @ 30 Amps Total
VS3 = +5Vdc @ 50 Amps
+3.3Vdc_Aux = +3.3Vdc @ 20 Amps
±12Vdc_Aux @ 3 Amps each

+270Vdc input Only; +270Vdc Input is on P0 pin P7 and
+270Vdc Return is on P0 pin P4
Standard outputs modified to have current share on 3.3_Aux
VS1/VS2 = +12Vdc @ 30 Amps Total
VS3 = +5Vdc @ 50 Amps
+3.3Vdc_Aux = +3.3Vdc @ 20 Amps
±12Vdc_Aux @ 3 Amps each
+270Vdc input Only; +270Vdc Input is on P0 pin P7 and
+270Vdc Return is on P0 pin P4
VS1/VS2 Modified to a +5vdc output with Current Share
capability
Current share on +3.3Vdc_Aux
No +/-12Vdc_Aux outputs
VS1/VS2 = +5Vdc @ 50 Amps Total
VS3 = +5Vdc @ 50 Amps
+3.3Vdc_Aux = +3.3Vdc @ 20 Amps
Complete Part number = VPX56-61AABEAA-04
Keys configured for +270Vdc input
Standard Outputs
Status LED
Current Share on +12Vdc, +5Vdc and +3.3Vdc_Aux Outputs
"SMB_Alert" Open Collector output signal that indicates to an
external controller that an out of tolerance condition exists on the
input voltage, output voltages, output current or current share.
This signal will be available on UD3 pin A1.
VS1/VS2 = +12Vdc @ 30 Amps Total
VS3 = +5Vdc @ 50 Amps
+3.3Vdc_Aux = +3.3Vdc @ 20 Amps
±12Vdc_Aux @ 3 Amps each
02


03



04
Output Configuration






VPX56-6 AC/DC Power Supply Specification
110 Wilbur Place, Bohemia, NY 11716
VPX56-6A001 Rev. F
Tel: 631.567.1100
Page 14