Gem-230A Satellite Brewer Instructions
IMPORTANT SAFEGUARDS & CONVENTIONS
MODELS INCLUDED
• Gem-230A
This appliance is designed for commercial use. Any servicing other than cleaning and maintenance should be
performed by an authorized Wilbur Curtis service center.
• Do NOT immerse the unit in water or any other liquid.
• To reduce the risk of fire or electric shock, do NOT open top panel. No user serviceable parts inside.
Repair should be done only by authorized service personnel.
•
•
Keep hands and other items away from hot parts of unit during operation.
Never clean with scouring powders, bleach or harsh implements.
CONVENTIONS
WARNINGS – To help avoid personal injury
Important Notes/Cautions – from the factory
Sanitation Requirements
Your Curtis Gemini System is Factory Pre-Set and Ready to Go… Right from the Carton.
Following are the Factory Settings for Gem-230A:
• Brew Temperature = 202°F
• Water Bypass = 35%
• Brew Volume = Set to 1½ gallons for Gem-230A.
System Requirements:
• Water Source 20 – 100 PSI (Minimum Flow Rate of 1 GPM)
• Electrical: See attached schematic for standard model or visit www.wilburcurtis.com for your model.
CAUTION: Please use
this setup procedure
before attempting to use
this brewer. Failure to follow the
instructions can result in injury or
the voiding of the warranty.
SETUP STEPS
The unit should be level (left to right and front to back), located on a solid counter top. Connect a water line from
the water filter to the brewer. NOTE: Some type of water filtration device must be used to maintain a troublefree operation. (In areas with extremely hard water, we suggest that a sedimentary and taste & odor filter be
installed.) This will prolong the life of your brewing system and enhance coffee quality.
The National Sanitation Foundation requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine
can be moved for cleaning underneath.
2. In some areas an approved backflow prevention device may be required between the brewer and
the water supply.
1. A 3/8” NPT x 1/4” Flare elbow is supplied for water line connection. Use tubing sized sufficiently to provide a
minimum of 1.0 GPM.
2. Connect the unit to an appropriate electrical power circuit.
3. Remove the top cover. Make sure the primary thermostat, Index Nº 4 in parts list, is turned off.
4. Open the water supply valve.
5. Turn on the main breaker. Turn on power at the toggle switch behind the brewer. At this time water will start
to flow into the heating tank.
6. Turn on power at the ON/OFF switch on the front switch panel. This will energize the controls and the
switches will light up.
7. Place a clean Satellite on the warmer deck and push the warmer switch to the on position to preheat the
Satellite.
8. When the heating elements are covered with water, turn the primary thermostat on (twist the stem clockwise
as far as it will turn).
9. Replace the heating tank lid and top cover on the brewer.
Allow 15 minutes for the water in the tank to reach brewing temperature (202º F). After the initial warm-up,
recovery is instantaneous. You may brew continuously.
CLEANING
¨
C
ISO 9001 REGISTERED
WILBUR CURTIS COMPANY
Montebello, CA 90640
Using a daily routine of cleaning the external parts of the Gemini 230A brewing system will maintain it's appearance and ensure great tasting coffee.
1. Wipe off any spills, dust or debris from the exterior surfaces.
2. Clean the outside covering of the brewer and satellite with stainless steel polish. Coarser agents may scratch
the machine.
3. Slide out the brew cone and rinse it thoroughly with clean water.
4. Remove the sprayhead and clean it. Clean around the dome area, wiping with a non toxic cleaner.
5. Clean the brew cone rails with a damp cloth or brush. Dry thoroughly with clean cloth.
FOR THE LATEST SPECIFICATIONS AND INFORMATION
GO TO WWW.WILBURCURTIS.COM
1
CARE AND
MAINTENANCE
Regular maintenance is essential in keeping your GEMINI system looking and working like new.
1. Remove the sprayhead (index Nº 14) from brewer and clean it once a week or more often in heavy lime areas.
CAUTION: Do not use
cleansers, bleach liquids,
or powders that contain
chlorine. These products cause
corrosion and pitting to stainless
steel and will void the warranty.
BREWING
INSTRUCTIONS
2. Clean faucet seat cups on the GEM-3 Satellite twice a week and replace when cracked or leaking.
3. Remove hot water spout aerator from the hot water spout and clean it at least once a week.
4. Periodic temperature checks in the water tank. If too low, thermostat should be adjusted by a qualified technician.
5. The inside of the heating tank should be de-limed at least every six months, especially in heavy lime area.
1. Brewer should be ON (Confirm at rear toggle switch, then press the ON/OFF button).
2. Place an empty Satellite on the warmer deck, under the brewcone. Press the warmer switch to preheat the
Satellite for 10 minutes.
NOTE – The indicator light will come on and remain lit during the brewing cycle to indicate the particular side of
the brewer that is in operation.
WARNING: HOT, allow brewcone to drain before removing.
3. Place a clean filter
into the brewcone.
ELECTRICAL SCHEMATIC
4. Fill brewcone with
ground coffee.
5. Transfer filled
brewcone to
brewer.
6. Press BREW
button to start
brew cycle.
GEMINI 230A
ILLUSTRATED PARTS
26
27
25
A
B
1
2
29
30
3
4
5
6
33
28
31
32
C
15
16
7
8
9
10
11
12
13
14
17
18
19
34
D
ITEM Nº
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
PART Nº
WC-5450
WC-37098
WC-5310*
WC- 517*
WC-3785
WC- 608*
WC-3921-01
WC- 200*
WC- 123*
WC- 121*
WC- 122*
WC-3301
WC-3357
WC-2906*
WC-2401
WC- 827*
WC-1501
WC-102
DESCRIPTION
COVER, TOP
KIT, BY-PASS GEN USE
TUBE, 5/16" ID SILICONE
THERMOSTAT
KIT, SPRAYHEAD GEM-12/230A
WATER LEVEL CONTROL 120V
LABEL, TOP GEM-230A
LIGHT, INDICATOR W/TNRMN CLIP 120V
SWITCH, ROCKER RED SPST 250V 15A
SWITCH, ON/OFF CLEAR SPST 250V 15A
SWITCH, BREW GREEN SPST 250V 15A
BASKET, WIRE 7" DIA BREW
BREWCONE ASSEMBLY COMPLETE
SPRAYHEAD, BLUE (.178")
ELBOW, 3/8" NPT x 1/4" FLARE
VALVE, INLET .75GPM 120V 10W
FUSE HOLDER ASSEMBLY W/5A FUSE
SWITCH, TOGGLE NON-LIT SPST 125-250V
20
21
23
24
22
ITEM Nº
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
PART Nº
DESCRIPTION
RELAY, SPST 120V COIL 50A
WC- 400R
WC-3921B-01 LABEL, BOTTOM PANEL
WC-1809*
FAUCET, HOT WATER PS/HPS SERIES
WC-3500
LEG, 4" ADJUSTABLE
DECK WARMER SS
WC-5451
KIT, WARMER ELEMENT 100W 120V
WC-37102*
WC-817*
VALVE, DUMP RT 120V 10W W/RECTIFIER
WC-3763*
KIT, DUMP VALVE REPAIR
WC- 604*
TIMER, BREW 1-8 MINUTES
TANK COMPLETE, 2KW 220V
WC-6272
WC-37008
KIT, TANK LID ROUND
WC-3691
INSULATION, HEATING TANK
WC- 522*
THERMOSTAT, HI-LIMIT HEATER CONTROL
WC- 906-04* HEATING ELMNT, 2KW 220V W/NUT/WSHR
WC-5502-01* PROBE ASSY, WATER LEVEL
WC-3765L*
KIT, INLET VALVE REPAIR
* RECOMMENDED PARTS TO STOCK