2. fundamental safety warning

• Children should be supervised toe nsure
that they do not play with the appliance.
FOR EUROPEAN MARKET ONLY:
• This appliance can be used by children
aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use
of the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
Keep the appliance and its cord out of
reach of children aged less than 8 years.
1. INTRODUCTION
Thank you for choosing a De’Longhi product.
Take a few minutes to read these instructions for use. This will
avoid danger or damage to the machine.
1.1 Symbols used in these instructions
The important warnings are represented by the symbols listed
here below. It is vital to observe these warnings. Failure to observe the warnings provided may result in electric shock, serious
injury, burns, fire or damage to the appliance.
Danger!
Failure to comply can be the cause of life-threatening injury by
electric shock.
Important!
Failure to comply can be or is cause of injury or damage to the
appliance.
N.B. :
This symbol highlights recommendations and important information for the user.
1.2 Problems and repairs
In the event of problems first try and resolve them by following the warnings provided in chapter “12. If something is not
working”.
For any repairs always contact a Technical Service Centre authorised by the Manufacturer only.
Always insist on the use of original spare parts.
Repairs carried out by unqualified personnel can be dangerous
and can invalidate the guarantee.
Danger!
This is an electrical appliance, it is therefore important to respect
the following safety warnings:
If the power cable is damaged, it must be
replaced by the manufacturer or the manufacturer’s Customer Services in order to avoid
any risk.
2. FUNDAMENTAL SAFETY
WARNING
•
•
•
Caution!
• The appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience and
knowledge, unless they have been given
supervision or instruction concerning use
of the appliance by a person responsible
for their safety.
•
•
•
•
•
•
11
Do not touch the appliance with wet hands.
Do not touch the plug with wet hands.
Ensure that the socket used can always be easily reached,
so that the plug can be removed when required.
If you wish to remove the plug from the socket, handle the
plug itself.
Never pull the power cable as it can be damaged.
To disconnect the appliance completely, you must remove
the plug from the socket.
Do not attempt to repair the appliance in the event of malfunction. Switch the appliance off, remove the plug from
the socket and contact After-Sales Technical Assistance.
Do not move the appliance by pulling the power cable.
It is dangerous to modify or alter the characteristics of the
appliance in any way.
•
•
•
•
3. SOME NOTIONS ON HUMIDITY
Avoid the use of extension leads for the electrical power
supply cable.
The appliance must be installed in accordance with national rules on household appliances.
The appliance must be connected to an efficient earthing
system. Have a qualified electrician check your electrical
circuit.
This appliance is not intended for use in the reclamation of
commercial or residential property damaged by water.
Air always contains a certain quantity of water in the form of
vapour; this determines the degree of humidity in a room.
The capacity of air to contain water vapour increases as its
temperature increases. This is why in our homes, as soon as the
temperature drops, the air releases the water vapour contained
in it, turning into condensation, which appears on all cold
surfaces such as windows, walls etc.
The dehumidifier is an electric appliance that extracts humidity
from the air, avoiding the damage that it causes. Studies have
shown that the ideal conditions for our health and home are
obtained with a relative humidity level between 40 and 60%.
With very low temperatures, you are recommended to heat
the room even minimally. This will increase the dehumidifying
capacity of the appliance considerably. This is the only way, in
fact, to allow the condensation that forms on the windows and
other cold surfaces to evaporate into the air and be collected
by the dehumidifier. The air released by the dehumidifier is,
however, generally warmer than the air in the room.
Caution!
Keep the packaging material (plastic bags, polystyrene foam)
out of the reach of children.
2.1 Use in compliant with its intended use
This appliance is intended for domestic use only. Use this appliance only as described herein. These instructions do not intend
to cover every possible condition and situation that may arise.
Common sense and caution should be applied when installing,
operating and storing any appliance.
4. DESCRIPTION
4.1 Appliance and accessories
2.2 General warnings
•
•
•
•
•
•
•
•
•
A1. Condensate collection tank
A2. Water level viewing window
A3. Lifting handles
A4. Air intake openings
A5. Air filter (anti-bacteria* or anti-dust - depending on
model) (* The anti-bacteria filter, in addition to trapping
dust particles, has an anti-bacterial action. Furthermore, it
considerably reduces other irritating agents such as pollen
and spores)
A6. Air outlet grille
A7. Accessory box containing condensate drain nozzle and 4
castors
A8. Continuous drain door
A9. Connector plug for continuous drain with pump
A10.Connector for continuous drain with pump
A11.Pipe for continuous drain with pump
Do not install the appliance in rooms where the air contains
gas, oil, sulphur or near sources of heat.
Do not use the appliance on sloping surfaces.
Keep the appliance at least 50 cm away from flammable
substances (alcohol, etc.) or pressurised containers (e.g.
aerosol cans).
Do not rest objects of any kind on top of the appliance.
Always transport the appliance upright or resting on one
side. Drain the condensate tank before moving the appliance. Wait at least 1 hour after transporting the appliance
before starting it
R 134a is a refrigerant gas that complies with EC environmental regulations, nevertheless avoid perforating the
refrigerant circuit of the appliance. At the end of its service
life, the air conditioner must be disposed of at a suitable
collection centre.
ENVIRONMENTAL INFORMATION: This unit contains fluorinated greenhouse gases provided for by the Kyoto Protocol.
The maintenance and disposal operations must be carried
out by qualified personnel only (R134a, GWP=1430 - for
further informations, see rating label).
The materials used for packaging can be recycled. You are
therefore advised to dispose of them in special differentiated waste collection containers.
Do not use the appliance outdoors.
Do not obstruct the air intake or outlet.
4.2 Control panel
B1.
ON/STAND-BY button: to switch the appliance on or
off
B2.
HYGROMETER/THERMOMETER button: to temporarily
display the relative humidity and temperature levels in the
room
B3. Display: for symbol and abbreviation meanings on the display, refer to the following chapters
B4 and B5. + DECREASE/INCREASE buttons:
-/
12
6. USE
• to set the percentage of humidity you wish to reach in
the room, by increasing or decreasing it by 5% at a time;
• to set the timer: from 0 to 10 hours, with 30-minute intervals; from 10 to 24 hours with 1-hour intervals;
B6. Read these instructions carefully before using the appliance.
• Keep these instructions in a safe place.
If the appliance is transferred to other owners, they must
also be provided with these instructions for use.
• Failure to comply with these instructions may result in injury and damage to the appliance.
The manufacturer is not liable for damage deriving from
the failure to comply with the instructions for use.
• Keep the list of Technical Service Centres and identify the
Centre nearest you.
DEHUMIDIFICATION button: to activate the dehumidification mode. Press repeatedly to select the desired dehumidifying level (MIN/MED/MAX/AUTO).
B7.
PUMP button: to activate continuous drain
with pump
B8.
TIMER button: to activate delayed operation or
switch-off
B9.
N.B. :
After having transported the appliance wait at least one hour
before starting it up.
LAUNDRY button: to activate the automatic rapid
laundry drying function
5. MAIN VISUALISATIONS ON THE DISPLAY
6.1 Electrical connections
During operation, symbols appear relevant to normal
functioning.
Here follows a summary of the main items displayed:
STAND-BY
This indicates that the appliance is in
Stand-by mode. Press
to switch
the appliance on.
TANK ALARM
The tank is full, absent, or positioned
incorrectly This alarm stops appliance operation until the empty tank
is positioned correctly.
DEFROSTING
INDICATOR
SENSOR ALARMS
KEYPAD LOCK
INDICATOR
PUMP OPERATION
Danger!
Before plugging the appliance into the mains, check the
following:
• The mains power supply corresponds to the working voltage indicated on the rating plate.
• The power socket and the electrical circuit are adequate for
the required load.
• The mains socket is suitable for the plug, otherwise have
the plug replaced by a qualified electrician.
• The mains socket is connected to an efficient earthing
system.
When the appliance operates at low
temperatures, it frequently carries
out a defrosting cycle, which is indicated by the relevant symbol.
6.2 Applying the castors
If you wish to apply the castors to the appliance, proceed as
follows:
1) Make sure the appliance is unplugged and the tank is
empty.
2) Remove the rubber caps from the base of the appliance by
pulling them out hard, using pliers if necessary (see figure
1/a).
3) Apply the castors by inserting their pins into the holes (see
figure 1/b).
Indicates a possible malfunction
of the sensors or that the ambient
humidity is too low to be detected.
Indicates that the keypad lock is
active
STATIC: indicates that the "PUMP"
function is active
FLASHING: the pump is not operating correctly (see chap. “12.
If something is not working”)
N.B. :
When carrying out these operations be careful not o incline the
appliance by more than 45°; in any case, once the castors have
been assembled, wait at least one hour before turning it on.
N.B. :
after a few minutes in stand by, the display turns off to save
energy.
6.3 Setting it up for use
Position the appliance in the room to be dehumidified. It is
essential to leave a free space of at least 50 cm in front of and
above the dehumidifier, so as not to obstruct the air intake and
13
7. MODE SELECTION
outlet. For efficient ventilation it is advisable to leave a space of
at least 5-10 cm all around the appliance.
Connect the appliance to a power socket.
The appliance operates in the previously set mode.
6.4 Draining the condensate water
7.1 Dehumidifying Mode
The condensate can be drained in 3 ways:
•
a) Draining into the tank
The condensate can be drained directly into the tank. When the
tank is full, the appliance stops and the display shows the tank
alarm
: remove the tank (Fig. 2) and empty it (e.g. in
a sink or bath tub).
Put the tank back in being careful to position the handle as show
in figure 3.
•
•
MIN
b) Continuous external draining
To use the appliance for long periods of time without periodically emptying the tank, use continuous draining proceeding as
follows:
• Open the door on the side of the appliance and screw the
nozzle onto the fitting (Fig. 4).
• Insert a garden hose into the nozzle and lead the end of the
hose to a floor-level drain. Make sure the tank is inserted
correctly.
• Make sure the hose is never placed at a height above the
level of the nozzle (fig. 5). Otherwise the water will continue to drain back into the tank. Make sure there are no
kinks in the hose.
MED
MAX
AUTO
Depending on ambient conditions, the appliance automatically stabilises both the
humidity and power levels
for dehumidification.
When the room has reached the set level of humidity, it will
stop. It starts again automatically as soon as the humidity level
returns to a percentage level higher than the requested level.
N.B. :
This method can be used when the condensate drainage must
not exceed any difference in level compared to the discharge of
the water.
7.2 LAUNDRY mode
c) Continuous drain with pump
The exclusive continuous drain with pump system allows for the
drainage of condensate when exceeding level differences of up
to 4 meters in height. Proceed as follows:
• Remove the protective plug (Fig. 6) and connect the pipe
supplied (A11) (Fig. 6);
• Make sure the hose is never placed at a height above 4 meters (fig. 7). Make sure there are no kinks in the hose.
• To desconnect the hose, push the ring nut of the connector
and extract (fig. 8).
•
N.B. :
"Continuous drain with pump" only operates if the "Pump"
•
•
•
Press the
button.
The display shows
and the previously-set level of relative humidity.
Press the + or - button to select the desired level of humidity (30% corresponds to a dry environment, 80% corresponds to a humid environment).
Press the
button repeatedly to select dehumidification power level.
Press the
button.
The display shows the relevant symbol and the appliance
works at its maximum dehumidifying capacity.
Recommended for particularly humid rooms or to dry laundry
more quickly.
8. ADDITIONAL FUNCTIONS
8.1 PUMP function
This function activates the pump to make use of the "CONTINUOUS DRAIN WITH PUMP"
function is activated with the relevant button
Keep the protective plug of the continuous drain with
pump connector and replace when removing the pipe
(A11).
To activate the function, press the
button while
the appliance is switched on.
The display shows the corresponding symbol.
N.B. :
Check that the continuous drain pipe (A11) is installed correctly.
14
8.2 Hygrometer/thermometer
•
9. CLEANING AND MAINTENANCE
Always unplug the appliance from the power socket before
performing any cleaning or maintenance operations. For safety
reasons, never wash the dehumidifier using a jet of water.
Press the
button.
The display shows the humidity level and then the temperature detected in the room.
9.1 Cleaning the cabinet
N.B. :
The values detected are indicative.
•
•
•
8.3 Keypad lock
Useful for preventing unwanted or accidental inputs on the
appliance.
• With the appliance switched off (not in stand by), keep
Clean with a slightly damp cloth and dry with a dry cloth.
Do not use petrol, alcohol or solvents to clean the appliance.
Do not spray liquid insecticide or similar products as they
may deform the plastic.
9.2 Air filter (anti-bacteria* or anti-dust - depending
on model)
-
both and
buttons pressed simultaneously
for at least 3 seconds, until the appliance emits an audible
signal.
The display shows
and the keypad will be locked.
To remove the lock, repeat the procedure.
If the filter is dirty, air circulation is compromised and consequentially the efficiency of the dehumidifier decreases. It is
therefore good practice to clean the filter at regular intervals.
Frequency depends on the conditions and duration of operation.
If the appliance is used constantly or frequently it is advisable to
clean the filter once a week.
• Once the tank has been taken out, remove the filter by pulling it downwards (fig. 6).
• Use a vacuum cleaner to remove dust accumulations from
the filter.
• If the filter is very dirty, rinse it well with warm water. The temperature of the water must not exceed 40°C. Once
washed, leave to dry completely before replacing.
8.4 Temperature scale
The temperature can be displayed in °C or °F.
• With the appliance switched off (not in stand by), press the
button for at least 20 seconds, until the appliance
emits an audible signal: the scale changes from °C to °F (or
vice-versa).
8.5 Timer
9.3 Air filter (anti-bacteria* or anti-dust - depending
on model)
How to programme delayed operation
1) With the appliance in stand-by (
), press the
button. The display shows the relevant symbol and time
delay before starting.
2) Use the + and - buttons to set the delay (from 0.5 to 24
hours).
3) Press the again to confirm the selection. The
symbol stays on.
When the set time has passed, the appliance will start
automatically.
If the filter is dirty, air circulation is compromised and consequentially the efficiency of the dehumidifier decreases. It is
therefore good practice to clean the filter at regular intervals.
Frequency depends on the conditions and duration of operation.
If the appliance is used constantly or frequently it is advisable to
clean the filter once a week.
• Once the tank has been taken out, remove the filter by pulling it downwards (fig. 6).
• Use a vacuum cleaner to remove dust accumulations from
the filter.
• If the filter is very dirty, rinse it well with warm water. The temperature of the water must not exceed 40°C. Once
washed, leave to dry completely before replacing.
How to programme delayed deactivation
1) With the appliance on (not in stand by), press the
button. The display shows the relevant symbol and time delay
before deactivating.
2) Use the + and - buttons to set the delay (from 0.5 to 24
hours).
3) Press the again to confirm the selection. The
symbol stays on.
When the set time has passed, the appliance will stop
automatically.
9.4 Air filter (anti-bacteria* or anti-dust - depending
on model)
If the filter is dirty, air circulation is compromised and consequentially the efficiency of the dehumidifier decreases. It is
therefore good practice to clean the filter at regular intervals.
Frequency depends on the conditions and duration of operation.
15
If the appliance is used constantly or frequently it is advisable to
clean the filter once a week.
• Once the tank has been taken out, remove the filter by pulling it downwards (fig. 6).
• Use a vacuum cleaner to remove dust accumulations from
the filter.
• If the filter is very dirty, rinse it well with warm water. The temperature of the water must not exceed 40°C. Once
washed, leave to dry completely before replacing.
9.5 Air filter (anti-bacteria* or anti-dust - depending
on model)
If the filter is dirty, air circulation is compromised and consequentially the efficiency of the dehumidifier decreases. It is
therefore good practice to clean the filter at regular intervals.
Frequency depends on the conditions and duration of operation.
If the appliance is used constantly or frequently it is advisable to
clean the filter once a week.
• Once the tank has been taken out, remove the filter by pulling it downwards (fig. 6).
• Use a vacuum cleaner to remove dust accumulations from
the filter.
• If the filter is very dirty, rinse it well with warm water. The temperature of the water must not exceed 40°C. Once
washed, leave to dry completely before replacing.
9.6 For long periods of inactivity
•
•
•
After unplugging the appliance from the power socket,
empty the tank.
Clean the filter and put it back in.
Cover the appliance with a plastic bag to protect it from
dust.
10. TECHNICAL FEATURES
Power supply voltage
Power consumption
Maximum absorbed power
Defrost device
Hygrometer
Fan speed
Air filter
Operating limits:
temperature
relative humidity
See rating plate
“
“
Yes
Yes
3
Yes
2°C - 32°C
30 - 90%
16
11. DISPOSING OF THE APPLIANCE
The appliance must not be disposed of with household
waste, but taken to an authorised waste separation and
recycling centre.
12. IF SOMETHING IS NOT WORKING
Check the following before calling the authorised TechnicalService Centre operating in your area.
PROBLEM
The appliance is operating in dehumidifying mode but the humidity does not
decrease.
CAUSE
SOLUTION
The filter is clogged.
Clean the filter.
Either the temperature or the humidity
in the room is too low.
In certain conditions it is normal for
the appliance not to dehumidify. Check
the operating limits of the appliance in
Chap. “10. Technical Features”. In certain
cases it is advisable to heat the room you
wish to dehumidify.
The room is too large for the dehumidifying power of the appliance, or there
are too many sources of humidity (boiling pots, etc.).
The appliance does not operate for approximately 3 minutes after start up.
The set humidity value is too high.
Decrease the set humidity value.
The safety device has correctly made the
appliance trip.
Wait for 3 minutes to pass.
The appliance stops working and " The tank is full.
Empty the tank and replace.
" (tank alarm) is shown on the The tank is absent, or positioned Put the tank back in place.
display
incorrectly
The temperature in the room is very low Increase, if
"
" is shown on the display (defrost and the appliance is performing a defrost temperature.
indicator)
cycle.
possible,
the
room
"
" is shown on the display (sensor Indicates a possible malfunction of the Move the appliance to another room with
sensors or that the ambient humidity is a level of humidity within the operating
alarms)
too low to be detected.
limits indicated in Chap. “10. Technical
Features” and check if the appliance
starts working again. If the problem persists, call the Service Centre.
I have prepared the appliance for use The "CONTINUOUS DRAIN WITH PUMP"
Press the
with "CONTINUOUS DRAIN WITH is activated by the "PUMP" function.
PUMP", but the condensed water still
drains into the tank.
appears flashing on the
display
button (B7).
The pipe for "CONTINUOUS DRAIN WITH The pump safety device has tripped. ProPUMP" is kinked or not inserted.
ceed as follows:
• See Par. “c) Continuous drain with
pump” to prepare the appliance
correctly;
• Disconnect the appliance from
mains power;
• Reconnect the appliance to mains
power and press the
button.
17