selectronic - American Standard

Installation Inst ru ct io n s
SELECTRONIC®
MODEL NUMBERS
DC POWERED PROXIMITY EXPOSED
URINAL FLUSH VALVE
0.125, 0.25, 0.5 & 1.0 GPF
6063.013 6062.601
6063.025 6063.505
6063.051 6063.510
6063.101 6063.513
Exposed Flushometer
for 3/4" Top Spud Urinals
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
Certified to comply with ASME A112.19.2
© 2017 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
(In Toronto Area only: 1-905-306-1093))
© 2017 AS America Inc.
1
M965647 REV. 1.6 (5/17)
Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your
installation proceeds smoothly--please read these instructions carefully before you begin.
UNPACKING
All American Standard Products Are Water Tested At Our Factory.
Some Residual Water May Remain In The Valve During Shipping.
Remove the Flush Valve items from the carton. The illustration below shows all items after they have been
removed from the carton. Some items may be packaged partially assembled to other items.
1. Installation Instructions
2. Flush Valve Body Assembly
3. Vacuum Breaker Tube
4. Spud Coupling Nut and Washers
5. Spud Flange
6. Wall Escutcheon
7. Cover Tube
8. Sweat Adapter
9. Stop Valve
CARE INSTRUCTIONS:
DO: CLEAN THE PRODUCT WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
DO NOT REMOVE PROTECTIVE FILM FROM SENSOR
EYE UNTIL INSTALLATION IS COMPLETE.
7
8
6
9
Installat ion Instruc tions
2
3
1
4
SELECTRONIC®
DC POWERED PROXIMITY EXPOSED
URINAL FLUSH VALVE
0.125, 0.25, 0.5 & 1.0 GPF
MODEL NUMBERS
6063.013
6062.601
6063.025
6063.505
6063.051
6063.510
6063.101
6063.513
Exposed Flushometer
for 3/4" Top Spud Urinals
CAUTION: Use only American Standard supplied
transformers and cable sets. Using non-AS supplied
cables, or cutting, splicing or modifying any components
will void the warranty.
© 2017 AS America, Inc.
NOTE TO INSTALLER: Please give this manual to the customer after installation.
To learn more about American Standard Selectronic® Products visit our website at: www.americanstandard-us.com
or e-mail us at: CRTTEAM@americanstandard.com
For Parts, Service, Warranty or other Assistance,
please call (844) CRT-TEAM / (844) 278-8326 (In Canada: 1-800-387-0369)
5
(In Toronto Area only: 1-905-306-1093))
2
M965647 REV. 1.6 (5/17)
Fig. 1 (Before November 2017)
GENERAL DESCRIPTION:
Roughing-in Dimensions Fig. 1
SELECTRONIC™ PROXIMITY URINAL FLUSH VALVE
Exposed Flushometer for 3/4" Top Spud Fixtures
Right or Left Hand Installation
See (Section 5) for converting Flush
Valve to Left Hand Installation.
FINISHED WALL
73 mm
(2-7/8")
MANUAL
OVERRIDE
BUTTON
15˚
127 mm
(5")
DETECTION ZONE
400 -800 mm
(15-3/4 TO 31-1/2)
(1" NPT)
L-C419 mm
(16-1/2")
292 mm
(11-1/2")
108-134 mm
(4-1/4" TO 5-1/4")
*-C-L152 mm MIN.
(6") MIN.
76mm MAX.
(3) MAX.
FOR 3/4" TOP
SPUD FIXTURES
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6 " (152 mm) above
fixture. Consult Codes for details.
Fig. 1A
(After November 2017)
Roughing-in Dimensions Fig. 1
FINISHED WALL
DETECTION ZONE
400 -800 mm
(15-3/4 TO 31-1/2)
73 mm
(2-7/8")
MANUAL
OVERRIDE
BUTTON
15˚
114 mm
(4-1/2")
(1" NPT)
L-C406 mm
(16")
292 mm
(11-1/2")
*-C-L152 mm MIN.
(6") MIN.
108-134 mm
(4-1/4" TO 5-1/4")
76mm MAX.
(3) MAX.
FOR 3/4" TOP
SPUD FIXTURES
*Note: The Critical Line (-C-L-) on Vacuum
Breaker must typically be 6 " (152 mm) above
fixture. Consult Codes for details.
3
M965647 REV. 1.6 (5/17)
RECOMMENDED TOOLS; Fig. 2.
Fig. 2
1. Teflon Tape
2. Flat Blade Screwdriver
3. Adjustable Wrench
4. Tape Measure
5. Hacksaw
6. Tubing Cutter
7. File
8. For Sweat Connection; Solder and Torch
9. 2.5 mm Hex Wrench
10. 1.5 mm Hex Wrench
2
1
3
4
10'
6
8
5
7
9
10
PRIOR TO INSTALLATION
• Flush all water lines prior to operation (See Step 4).
Dirt and debris can cause flush valve to run continuously.
Note: Prior to installing the Selectronic™Flush
Valve the following items must be installed.
1. Urinal
2. Drain line
3. Water supply line
•W
ith the exception of Stop Valve Inlet, DO NOT
use pipe sealant or plumbing grease on any
valve component or coupling!
IMPORTANT:
•P
rotect the chrome or special finish on the Flushometer.
DO NOT USE toothed tools on finished surfaces to install
or service these valves. Also see “Care and Cleaning”
section of this manual.
•A
ll plumbing and electrical wiring should be
installed in accordance with applicable codes
and regulations.
• The use of water hammer arrestors is strongly recommended for commercial applications. All piping
behind the walls should be properly secured and
fastened.
• Water supply lines must be sized to provide an
adequate volume of water for each fixture.
• This product contains mechanical and/or electrical
components that are subject to normal wear. These
components should be checked on a regular basis and
replaced as needed to maintain the valve’s performance.
4
M965647 REV. 1.6 (5/17)
FLUSH VALVE INSTALLATION
Fig. 3
FINISHED WALL
1 INSTALL SWEAT ADAPTER; Fig. 3
CAUTION
A
Turn water supplies off before
beginning
(A-B)=
C
Note: Install Optional Sweat Adapter (Supplied) for
copper pipe supply line.
CENTER LINE OF
FIXTURE SPUD
B
32mm
(1-1/4")
FILE EDGES
1. Measure the distance (A) from the finished wall to the center of the inlet spud on the fixture.
2. Cut the supply pipe 1-1/4" (A-B=C) shorter than the
measurement taken in Step 1. File any rough edges
off the end of the supply pipe.
CLEAN
ADAPTER
3. Clean the end of the supply pipe. Push the threaded Adapter until it is seated against the internal stop.
Sweat the Adapter to the pipe.
SOLDER
ADAPTER
2 INSTALL COVER TUBE, WALL
ESCUTCHEON and STOP VALVE;
Fig. 4
Fig. 4
FINISHED WALL
X
Fig. 4a
1. M
easure from finished wall to first thread of Adapter or
threaded supply pipe (dimension “X”). Cut COVER TUBE
(1) to length (X). Apply Teflon Tape to the threaded end of
the Adapter or supply pipe.
2. P
ush WALL ESCUTCHEON (2) onto the COVER TUBE (1).
Slide both onto the SUPPLY PIPE (3).
TEFLON TAPE
2
Fig. 4b
3
3. P
ush the COVER TUBE (1) in to expose the threads of the supply pipe. With a wrench thread the STOP VALVE
(4) onto the SUPPLY PIPE (3). Align and tighten.
4. P
ull COVER TUBE (1) against STOP VALVE (4) and push
WALL ESCUTCHEON (2) against finished wall.
1
2
X
4
Fig. 4c
1
3 I NSTALL VACUUM BREAKER
TUBE; Fig. 5
Fig. 5
1. Place the SPUD FLANGE (1) over the spud on
the Fixture.
2. Place FRICTION WASHER (3) and SEAL WASHER
(4) inside SPUD COUPLING NUT (2) and thread
onto Spud. Do not tighten fully.
3. Insert the VACUUM BREAKER TUBE (5) into the
SPUD COUPLING NUT (2) and push it down.
Note: If cutting VACUUM BREAKER TUBE (5) to size, note
that Critical Line (C/L) on Vacuum Breaker must typically
be 6" (152mm) above fixture. Consult Code for details.
5
2
1
5
3
4
3/4" TOP SPUD
M965647 REV. 1.6 (5/17)
LUSH OUT SUPPLY LINES; Fig. 6
4 F
Fig. 6
2
1. Remove STOP VALVE COVER (1) from STOP VALVE (2).
REMOVE COVER
2. Open STOP VALVE (2) with a flat blade screwdriver.
1
3. Turn on water supply to flush line of any debris or sediment.
4. Close STOP VALVE (2) and replace STOP VALVE COVER (1).
2
EFT OR RIGHT HAND
5 L
INSTALLATION; Fig. 7
COUNTER-CLOCKWISE
OPENS STOP VALVE
The unit is shipped with adjustable tailpiece on the
right side. If needed, the orientation can be modified
by following the steps below.
CLOCKWISE CLOSES
STOP VALVE
1. L
oosen SET SCREW (1) with 2.5mm Hex Wrench (4)
in back of FLUSH VALVE COVER (2).
Fig. 7
2. Rotate FLUSH VALVE COVER (2) to the right and pull off.
3. Rotate FLUSH VALVE BODY (3) 180˚.
2
4. R
eplace COVER (2) and rotate until key engages. Tighten SET SCREW (1).
2
1
6 INSTALL FLUSH VALVE; Fig. 8, 8a
3
1. I nsert ADJUSTABLE TAILPIECE (1) into the STOP
VALVE (2). Lubricate the O-RING (3) with water if
necessary. Lightly tighten COUPLING NUT (4). Fig. 8.
4
Important: Do not use lubricants (other than water) or
any type of thread sealing paste or tape.
180˚
2. A
lign the FLUSH VALVE BODY (5) directly above the
VACUUM BREAKER TUBE (7) and VACUUM BREAKER
COUPLING NUT (6). Fig. 8a.
KEY
2
Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for
the 121mm (4-3/4) dimension. Fig. 8a.
3. Pull the VACUUM BREAKER TUBE (7) up to meet the
threaded FLUSH VALVE BODY (5), hand tighten the
VACUUM BREAKER COUPLING NUT (6). Align all
components of the flush valve assembly. Fig. 8a.
4 1
4. Lightly tighten the COUPLING NUT (4) connection first,
then the VACUUM BREAKER COUPLING NUT (6) and
finally the SPUD COUPLING NUT (8). Once alligned correctly, use a wrench to tighten couplings to make water tight connections. Fig. 8a.
Fig. 8
Fig. 8a
121mm,+13mm, -6mm
(4-3/4)(+1/2, -1/4)
2
4
5
6
7
8
1
4
3
6
M965647 REV. 1.6 (5/17)
MAINTENANCE
Fig. 9
1
REMOVE COVER
DJUST STOP VALVE; Fig. 9
A A
IMPORTANT: To avoid overflowing, the STOP VALVE (3)
must never be opened to the point where the flow from
the valve exceeds the flow capacity of the fixture.
3
2
COUNTER-CLOCKWISE
OPENS STOP VALVE
1. After installation is complete, peel off the PROTECTIVE
FILM (1) from the sensor. Standing to one side, block the
sensor with your hand for 10 seconds. Remove your hand
and listen for audible “click” from within the valve.
CLOCKWISE CLOSES
STOP VALVE
2. Remove STOP VALVE COVER (2) from STOP VALVE (3).
Turn on water supply 1/4 turn to 1/2 turn(CCW) and test
for leaks.
Note: Unit may flush for approximately 5 to 10 sec.
when water is first turned on. If flow persists, turn
water off and repeat step #1 above.
3. Actuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds.
NOTE: Stand outside of sensor detection area.
B) Remove hand from in front of the sensor; unit will flush
in approximately 3 seconds.
4. Adjust STOP VALVE (3) after each flush until the stated
flush volume is achieved, no splashing occurs and the
fixture is properly cleansed.
5. When adjustment is complete, replace STOP VALVE
COVER (2) and tighten to ensure vandal-resistance.
ETROFITING WITH SELECTRONIC
B R
VALVE; Fig. 10
(Replaces Industry Standard Manual and
Electronic Valves)
Fig. 10
6
2
1
Note: In most Retrofits the wall escutcheon, stop valve,
cover tube and vacuum breaker do not have to be
replaced. If these items do need replacement they must
be purchased separately or order the complete flush
valve assembly from American Standard.
CLEAN
CONNECTIONS
4
5
3
1. Remove STOP VALVE COVER (1) from STOP VALVE (2).
2. Turn water supply off.
3. Loosen SPUD COUPLING NUT (3). Unthread COUPLING
NUT (4) and VACUUM BREAKER COUPLING NUT (5).
Remove FLUSH VALVE (6).
4. Clean all threaded connections before installing the new
flush valve.
5. Refer to Sections 4, 5 and 6 to complete the retrofit
installation.
7
M965647 REV. 1.6 (5/17)
C REPLACE BATTERY; Fig. 11, 11a
Fig. 11
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in
back of FLUSH VALVE COVER (3). Fig. 11.
3
1
2. Rotate COVER (3) to the right and pull off. Fig. 11.
3. T
urn COVER (3) over and disconnect the SENSOR (4)
from the BATTERY HOLDER (5). Remove the BATTERY
CONTAINER (6) with BATTERY HOLDER (5) and
BATTERY (7) inside. Fig. 11a.
2
4. Remove BATTERY HOLDER (5) from BATTERY
CONTAINER (6). Fig. 11a.
5. Remove old BATTERY from BATTERY HOLDER (5).
Install the new BATTERY (7) making sure the shape
of the BATTERY follows the shape of the BATTERY
HOLDER (5). Fig. 11a.
Fig. 11a
6. Insert BATTERY HOLDER (5) with BATTERY into
BATTERY CONTAINER (6). Insert BATTERY
CONTAINER (6) into flush valve COVER (3). Fig. 11a.
STANDARD BATTERY
5
7. Connect BATTERY HOLDER (5) to SENSOR (4) and
reverse the above steps to assemble flush valve. Fig. 11a.
INSTALL
NEW
BATTERY
REMOVE OLD
BATTERY
-P2
CR
-P2
CR
7
REMOVE
BATTERY
HOLDER
3
5
6
6
4
5
Fig. 11b
LONG LIFE POWER PACK
REMOVE OLD
LONG LIFE
POWER PACK
3
8
8
8
4
INSTALL NEW
LONG LIFE
POWER PACK
M965647 REV. 1.6 (5/17)
D SET DETECTION RANGE
(If Required); Fig. 13 & 14
Fig. 13
Note: The detection distance is preset and ideal for most
installations. Should an adjustment be required, follow
the steps below.
6
1
3
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in
back of FLUSH VALVE COVER (3). Fig. 13a.
2. Rotate COVER (3) to the right and pull off. Fig. 13b.
VIEW “A”
2
3. T
urn COVER (3) over and disconnect CABLE (4) from
BATTERY HOLDER (5). Fig. 13.
4. K
eeping hands away from the sensor detection area,
reconnect the SENSOR (4) and quickly place the COVER
(3) on the valve. Do not secure the COVER (3) at this time.
Note: You have 5 seconds to begin entering the program
code after power connection is made.
5. W
hile the SENSOR CONTROL LED (1) is blinking slowly,
place your hand 1 to 2 in. (30-50mm.) in front of the sensor.
Fig. 14.
STANDARD BATTERY
6. W
hen the LED (1) stops blinking and stays “ON”, move your
hand to the desired position and hold in place until the LED
(1) begins to blink again. Fig. 14.
3
Note: Detection Zone is 400mm - 800mm.
(Factory Setting: 400mm)
7. O
nce the SENSOR CONTROL LED (1) begins to blink
again, remove your hand from the detection zone.
When the flashing stops, the detection distance is set.
VIEW “A”
8. Replace and secure COVER (3) onto valve.
5
9. A
ctuate the FLUSH VALVE:
A) Cover sensor with hand for 10 seconds.
NOTE: Stand outside of sensor detection area.
B) Remove hand from in front of the sensor; unit will
flush in approximately 3 seconds.
Fig. 14
1
1" - 2" (30mm - 50mm
4
DETECTION ZONE
400mm TO 800mm
(Factory Setting: 400mm)
BLINKING LED
1
9
BLINKING LED
M965647 REV. 1.6 (5/17)
TROUBLESHOOTING FLOW CHARTS
UNIT DOES NOT FUNCTION
IS ANGLE STOP OPEN?
NO
OPEN VALVE
YES
CRITICALLY LOW BATTERY . INSTALL
NEW BATTERY
YES
REPEATED DOUBLE
FLASH ON SENSOR?
NO
1
RECONNECT BATTERY TO SENSOR.
FLASH ON SENSOR FOR 5
SECONDS?
NO
1
NO
2
2
DEAD BATTERY. INSTALL NEW
BATTERY. REPEAT.
DAMAGED SENSOR WIRE. REPLACE
SENSOR. (ONLY IF ABSOLUTELY NEEDED)
YES
PUSH MANUAL OVERRIDE
BUTTON; WILL THE UNIT FLUSH?
DAMAGED SOLENOID. REPLACE
SOLENOID
YES
NO
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
REPLACE PISTON ASSEMBLY.
(844) CRT-TEAM / (844) 278-8326
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
UNIT WILL ONLY FLUSH MANUALLY
CLOSE ANGLE STOP AND OPEN
AGAIN TO PRIME THE VALVE.
DOES FLUSHING STOP?
Product names listed herein are tr ademar ks of AS Amer ica, Inc. ©201 7
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
NO
PUSH MANUAL OVERRIDE
BUTTON. DOES IT RETURN TO ITS
ORIGINAL POSITION FREELY?
DAMAGED MANUAL OVERRIDE
BUTTON. REPLACE MANUAL
OVERRIDE BUTTON
NO
YES
1
RECONNECT BATTERY TO SENSOR.
FLASH ON SENSOR FOR 5
SECONDS?
2
NO
NO
1
DEAD BATTERY. INSTALL NEW
BATTERY. REPEAT.
2
DAMAGED SENSOR WIRES. REPLACE
SENSOR. (ONLY IF ABSOLUTELY NEEDED)
YES
REPLACE PISTON & SOLENOID
ASSEMBLY.
UNIT IS CONTINUOUSLY FLUSHING
REPEATED DOUBLE
FLASH ON SENSOR?
CRITICALLY LOW BATTERY. INSTALL
NEW BATTERY
YES
NO
RECONNECT BATTERY TO SENSOR.
FLASH ON SENSOR FOR 5
SECONDS?
1
2
NO
1
DEAD BATTERY. INSTALL NEW
BATTERY. REPEAT.
NO
2
DAMAGED SENSOR WIRES. REPLACE
SENSOR. (ONLY IF ABSOLUTELY NEEDED)
YES
REPLACE SOLENOID.
10
M965647 REV. 1.6 (5/17)
BEFORE NOVEMBER 2017
BEFORE NOVEMBER 2017
AFTER NOVEMBER 2017
Standard Battery (6063. Series)
Standard Battery (6063. Series)
SELECTRONIC®
DC POWERED PROXIMITY EXPOSED
URINAL FLUSH VALVE
0.125, 0.25, 0.5 & 1.0 GPF
M964942-0020130A
COVER ASSEMBLY (0.125 gpf)
M970343-0020130A
COVER ASSEMBLY (0.125 gpf)
MODEL NUMBERS
M964942-0020250A
COVER ASSEMBLY (0.25 gpf)
M970343-0020250A
COVER ASSEMBLY (0.25 gpf)
6063.013 6062.601
M964942-0020500A
COVER ASSEMBLY (0.5 gpf)
M970343-0020500A
COVER ASSEMBLY (0.5 gpf)
M964942-0021000A
COVER ASSEMBLY (1.0 gpf)
M970343-0021000A
COVER ASSEMBLY (1.0 gpf)
6063.025 6063.505
6063.051 6063.510
6063.101 6063.513
M950319-0070130A
SENSOR ASSEMBLY (0.125 gpf)
A917376-0070A
SET SCREW
M950319-0070300A
SENSOR ASSEMBLY (0.25 gpf)
A917376-0070A
SET SCREW
M906684-0070A
BONNET NUT
M906684-0070A
BONNET NUT
M964802-0070A
SOLENOID & PISTON
SUBASSEMBLY
M964802-0070A
SOLENOID & PISTON
SUBASSEMBLY
M964302-0070A
SOLENOID ASSEMBLY
M964302-0070A
SOLENOID ASSEMBLY
M964801-0070A
PISTON ASSEMBLY
M964801-0070A
PISTON ASSEMBLY
M950319-0070500A
SENSOR ASSEMBLY (0.5 gpf)
M950319-0071000A
SENSOR ASSEMBLY (1.0 gpf)
Power Source
Standard Battery
6063. Series
M950514-0070A
BATTERY HOLDER
A912809-0070A
O-RING
M964402-0070A
VACUUM BREAKER KIT
M964412-0020A
3/4" VACUUM
BREAKER ASSEMBLY
OPTIONAL ADJUSTABLE TAILPIECE
(Purchased Separately)
M962836-0020A (8-1/4" to 9-1/4" Rough-in)
M962835-0020A (7-1/4" to 8-1/4" Rough-in)
M962834-0020A (6-1/4" to 7-1/4" Rough-in)
M962833-0020A (5-1/4" to 6-1/4" Rough-in)
A955057-0020A
1" INLET PIPE ASSEMBLY
FOR (6062.601)
M952261-0020A
3/4" INLET PIPE ASSEMBLY
M955062-0020A
1-1/4" VACUUM
BREAKER ASSEMBLY
FOR (6062.601)
A955056-0020A
1" STOP VALVE KIT
M955058-0020A
3/4" STOP VALVE KIT
M964347-0020A
STOP VALVE CAP
M962926-0070A
1" SWEAT ADAPTER
M952262-0020A
3/4" SPUD ASSEMBLY
2
CR-P
M964945-0020A
ADJUSTABLE TAILPIECE
(4-1/4" to 5-1/4" Rough-in)
M950354-0020A
MANUAL VALVE
M962801-0070A
FLOW REGULATOR
(Before July 2015)
M923189-0070A
FLOW REGULATOR
(After July 2015)
A923654-0070A
BATTERY 6V CR-P2
M964075-0070A
3/4" SWEAT ADAPTER
M952208-0020A
1-1/4" SPUD ASSEMBLY
FOR (6062.601)
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
(844) CRT-TEAM / (844) 278-8326
Mon. - Fri. 8:00 a.m. to 8:00 p.m. EST Saturday 10:00 a.m. to 4:00 p.m. EST
IN MEXICO 01-800-839-1200
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
P ro du c t n a m e s lis t e d h e re in a re t r a de m a r k s o f A S A m e r ic a , I n c . ©2 0 1 7
To learn more about American Standard Selectronic® Products visit our website at:
www.americanstandard-us.com or e-mail us at: CRTTEAM@americanstandard.com
11
M965647 REV. 1.6 (5/17)
Download PDF

advertising