MCR 24, 24/28MI, 30/35MI, 34/39MI - kros.lv

MCR 24, 24/28MI, 30/35MI, 34/39MI
Wall-hung gas condensation boilers
Instructions for
use
English
08/06/06
Contents
Symbols used. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1
2
3
4
5
6
7
Parameter display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Setting different parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Setting the manual mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Modifying the water outlet temperature in the heating installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Switching off the central heating (In summer mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Setting the domestic water temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Modifying the comfort setting (ECO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Maintenance and periodic checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
Congratulations on choosing a DE DIETRICH product, a product of quality. We strongly recommend that you read the following instructions in
order to guarantee the optimal operation of your appliance. We are sure that you will not be disappointed and that it will satisfy all of your
expectations.
Symbols used
danger
Caution
Risk of injury and damage to equipment. Attention must be
paid to the warnings on safety of persons and equipment
Important information
Information must be kept in mind to maintain comfort
ZReference
Refer to another manual or other pages in this instruction
manual
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
3
Recommendations
If- Doyounotsmellusegas:
a bare flame, do not smoke, do not actuate
electrical contacts or switches ( doorbell, light, motor, lift,
etc..),
- Cut the gas supply,
- Open the windows,
- Extinguish all flames,
- Evacuate the premises,
- Consult your fitter or the maintenance company,
- Inform the gas supplier.
the event of flue gas emanation:
In- Switch
the boiler off,
- Open the windows,
- Evacuate the premises,
- Consult your fitter or the maintenance company.
Advised positions: Boiler
- It is forbidden to store inflammable products and
materials in the boiler room or close to the boiler, even
temporarily,
- MCR boilers must be installed in a frost-free environment,
- The boiler's ignition device must always be accessible.
Temperature:
- The tap water temperature is factory set at 55°C; this
temperature can be set to 65°C
- The maximum temperature that the water can reach in the
boiler is 95°C. The temperature in the radiators can reach
the maximum value programmed for the boiler,
- When the boiler is operating, the discharge conduit may
reach a higher temperature.
Maintenance: We recommend doing this at least once a year
Maintenance and cleaning of the heater must be carried out at
least once a year by a qualified technician.
Installation, commissioning, maintenance and repairs must be
carried out by authorised specialists (approved heating
engineers / installers).
For a proper operating of the boiler, follow carefully the
instructions.
4
Aeration
France: the cross section of the aeration vent, which is compulsory
in the premises in which the boiler is installed, must comply with the
DTU 61.1 (P 45 204) standard and, in particular, with the instruction
on general improvement work (Book 1764 April 1982).
Belgium:the cross-section of the aeration vents, which are
compulsory in the room in which the boiler is installed, must comply
with the NBN B 61-002,NBN D 51-003,NBN D 51-006 standard.
air inlet into the premises must in no event be
The
obstructed, even partially.
Maintenance
The boiler must be serviced and fully cleaned and the flue gas
conduit swept by a qualified professional at least 1 times per year.
We recommend that you take out a maintenance contract.
Precautions against frost
MCR boilers must be installed in a frost-free environment.
If the temperature of the central heating water in the boiler falls too
much, the integrated protection device switches itself on:
- If the water temperature is lower than 7°C, the circulating pump is
activated,
- If the water temperature is lower than 3°C, the boiler is activated,
- When the water temperature is above 10 °C, the boiler is switched
off and the circulation pump runs for another 15 minutes.
a room thermostat, connected via connectors 7 and 8, is
Ifactivated,
the boiler will operate permanently until it
reaches the outlet setting point.
function is a protection device for the boiler only, not
This
for the system or buiding fabric.
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
Control panel
The control panel of the MCR boiler has 6 function keys, an on/off
switch and a screen.
A Menu key
B Display
C Main ON/OFF switch
D Pressure gauge
E
Sweep key
F
"Escape" or "Reset" key
G Heating temperature adjustment key or H DHW temperature adjustment key or +
J
Maintenance key or enter
The display includes 4 positions and several symbols which indicate
the operating status of the control panel and any disturbances.
Figures, points and/or letters may be displayed.
The symbols located above the function keys indicate their current
function.
When a key has not been touched for 3 minutes, the display lighting
goes out and only the symbols , 2 and are displayed.
Pressing on any key will display the current status of the boiler and
the current command code. If there is a malfunction, the
corresponding code continues to be displayed.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
5
1 Parameter display
The following parameters can be displayed in the information menu
:
-
t1 = Flow temperature (°C)
t2 = Return temperature (°C)
t3 = Tank sensor (°C)
t4 = Outside temperature (°C)
FL = Ionisation current (µA)
nF = Fan speed (rpm)
- Press the Ä key. The symbol flashes. To access the
parameters, press key l.
- Press the + key successively to scroll down the various
parameters.
6
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
2 Setting different parameters
Parameters P1 to P6 can be modified by the user in order to meet
central heating and DHW comfort needs.
- Press key Ä several times until the symbol flashes on the menu
bar.
- Press the l key. The symbol P:1 appears. The symbol 1
flashes.
- Press the l key a second time. The symbol 75 appears (75 °C:
Factory setting).
- Press the - or + key to modify the value.
- To confirm, press the l key. The symbol P1 appears (The
symbol 1 flashes).
- Press key 2 time to return to the current operating mode.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
7
Parameter
Description
Comments
Factory setting
24
24/28MI
30/35MI
P1
Flow temperature Tset
20 to 85 °C
75 °C
P2
DHW Tset
40 to 65 °C
55 °C
34/39MI
0 = Heating programme deactivated, DHW programme
deactivated
P3
Boiler regulation
1 = Heating programme activated, DHW programme
active
2 = Heating programme activated, DHW programme
deactivated
2
1
1
1
3 = Heating programme deactivated, DHW programme
active
0 = Comfort
P4
Energy-saving mode
1 = Energy-saving mode
2
2 = Regulation operated by the controller
P5
Anticipation resistance
P6
The screen goes off
automatically
0 = No anticipation resistance for the ON/OFF thermostat
1 = Anticipation resistance for the ON/OFF thermostat
0
0 = The screen stays off
1 = The screen stays on
2
2 = The screen goes off automatically (After 3 minutes)
3 Setting the manual mode
- Press key Ä several times until the symbol flashes on the
menu bar.
- Press the l key. The minimum outlet temperature P1 or the text
Auto is displayed if an outside temperature sensor is installed.
- Press the + key to increase the outlet temperture manually.
- To confirm, press the l key.
The installation is in manual mode.
- Press key 1 time to deactivate the manual mode.
- Press key 1 time to return to the current operating mode.
8
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
4 Modifying the water outlet temperature in the heating
installation
5 Switching off the central heating (In summer mode)
-
-
Starting from the current operating status, press key .
The symbol and the current temperature are displayed.
Press the + or - key to modify the value.
To confirm, press the l key.
08/06/06 - 300008487-001-A
Starting from the current operating status, press key .
The symbol and the current temperature are displayed.
Press the - key until the OFF symbol is displayed.
Press the l key to modify the setting.
The symbol appears.
production of domestic hot water: activated.
MCR 24, 24/28MI, 30/35MI, 34/39MI
9
6 Setting the domestic water temperature
-
10
Starting from the current operating status, press key .
The symbol and the current temperature are displayed.
Set the temperature using keys + and -.
Press the - key until the OFF symbol is displayed.
Press the l key to modify the setting.
The symbol appears.
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
7 Modifying the comfort setting (ECO)
The user can consult or modify the following 3 settings:
- ON = Activation of the energy-saving setting.
- OFF = Activation of the comfort setting
- AUTO = Setting dependent on the control unit (=Factory setting).
Press the Ä key. The symbol flashes.
Press the Ä key a second time. The symbol ECO flashes.
To confirm, press the l key.
The current operating status is shown on the display: ECO.
Press the key to return to the ECO menu or press the + key
to modify the status.
- To confirm, press the l key.
- Press key 1 time to return to the current operating mode.
-
In ECO mode: I
If the ECO mode is set to I, when the boiler is used with an
external hot water tank, the water is not heated. If the hot water
tank is empty, the tap water will therefore be cold.
In ECO mode: Auto
If the setting is on Auto and the control unit is fitted with a ECO
function, the appliance adapts to the control unit setting.
For example: The ECO setting is tripped at night during reduced
temperature operation.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
11
Troubleshooting
Problem
There is no domestic hot water
Probable causes
Solution
The boiler is not working
Check that the boiler is switched on
Check the fuses and switches
Gas stop valve open
The water level and/or pressure are too low
(<1 bar)
Check the water pressure in the installation
The energy-saving shower head is allowing too little
Clean the shower head; replace it if necessary
water to pass
The boiler thermostat is set too low
Set the room thermostat or the regulator
The radiator valves are closed
Open the valves on all radiators connected to the heating
system
The boiler is not working
Check that the boiler is switched on
Check the fuses and switches
Gas stop valve open
The radiators are cold
The boiler is not working
The water level and/or pressure are
too low (<1 bar)
The water level and/or pressure are too low
Top up the installation with water
The boiler thermostat is set too low
Set the room thermostat or the regulator
The boiler is not working
Check that the boiler is switched on
Check the fuses and switches
Gas stop valve open
The water level and/or pressure are too low
Top up the installation with water
Internal problem
To restart the boiler, press the reset button: Reset
Correct the error if possible. If the problem persists, consult
your fitter
The minimum operating pressure of the gas must
be sufficiently high
Check the gas pressure upstream from the boiler
Check that the manometer is working correctly
The water level and/or pressure are too low
Top up the installation with water
Carry out a visual check for the presence of any
water leaks
Contact your fitter
Significant variations in domestic hot
Insufficient water supply
water temperature
Check the pressure of the installation: Open the valve
The central heating pipe connections are too tight
Loosen the connections
Grease the connections
Ensures that there is no air in the heating pipes
It is essential that you bleed any air in the calorifier, the
conduits or the taps to prevent the annoying noises likely to be
produced during heating or when drawing off water
The water is circulating too quickly in the central
heating system
Contact your fitter
Significant water leak under or close
The boiler or central heating pipes are damaged
to the boiler
Contact your fitter
Clicking in the central heating pipes/
Radiator circuit
When you inform your fitter of an error, tell him:
- Boiler type,
- Serial number. These indications can be found on the rating plate
affixed on the bottom of the boiler.
- Type of gas used.
12
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
Filling, bleeding and draining the installation
The water pressure in the boiler must be between 1.5 and 2 bar. Add
water to the installation if necessary.
Filling the heating circuit
Switch the boiler off.
1
2
3
4
LTALW7H000215b
- Open the valves on all radiators connected to the heating system.
- Set the room thermostat to as low a temperature as possible.
Wait until the temperature drops below 40°C and the radiators seem
cold before filling the central heating system.
Ensure that the boiler is switched off.
When filling the system, use the disconnecteur.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
13
- Open the valve (1/4 turn).
- Close the disconnecteur when the manometer indicates a
pressure of 2 bar.
- Fill the low flow heating circuit using the drainage tap in order to
favor the bleed.
- When the pump has stopped, bleed again and top up the water
pressure.
Filling and bleeding the installation 2 times a year should be sufficient
to obtain an adequate hydraulic pressure.
If it is often necessary to top up the installation with water, contact
your fitter.
- Reset the boiler.
14
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
Bleeding the heating system
It is essential that you bleed any air in the calorifier, the conduits or
the taps to prevent the annoying noises likely to be produced during
heating or when drawing off water.
- Bleed the radiators.
- Open the valves on all radiators connected to the heating system.
- Set the room thermostat as high as possible. Wait until the
radiators are hot.
- Switch the boiler off.
- Open the bleed connection using the bleed key provided whilst
keeping a rag pressed against the connection.
The radiators are cold.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
15
- Switch on the boiler. A bleed cycle of a duration of around 3
minutes is carried out automatically.
- Wait until water comes out of the bleed valve and then close the
bleed connection.
The water may still be hot.
- Check regularly that the installation contains water and is
pressurised. Add water to the installation if necessary.
16
- Set the room thermostat or the regulator.
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
Draining the heating circuit
It may be necessary to drain the boiler if the radiators have to be
replaced in the event of significant leakage or danger of frost.
- Open the valves on all radiators connected to the heating system.
- Connect a hose and open the drainage valve at the lowest point of
the installation.
The water may still be hot.
- Set the room thermostat to as low a temperature as possible.
- Switch the boiler off.
- Open the bleed connection using the bleed key provided whilst
keeping a rag pressed against the connection. If water continues
to escape, close the connection and try again later.
- The radiators are cold.
- Open the valves on all radiators connected to the heating system.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
17
MCR boiler off
Boiler without antifreeze protection
Before any work is carried out on the equipment / heating system, the
power supply must be disconnected (by means of the appropriate
fuse or main switch, for example) and warning must be given before
any reconnection.
In the event of prolonged absences (weekend, holidays): Switch the
boiler off.
Boiler with antifreeze protection
If the central heating system is not used for a long period, we
recommend switching the boiler off.
LTALW7H000217a
- Set the room thermostat or the regulator: for example 10 °C.
- Close the gas valve.
- Define parameter P4 as 1 (energy-saving mode); the heat
retention function will be deactivated.
The boiler will then only start up to protect itself from frost.
18
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
Switch on the boiler
- Set the boiler regulation to the desired values. The boiler will then
operate automatically.
- Checking the hydraulic pressure. The hydraulic pressure must be
a minimum of 1 bars. Add water to the installation if necessary.
Error code
If the boiler does not operate normally, an error message is
displayed.
If there is a problem, contact your fitter, specifying the alarm
code.
- Turn the boiler on. The boiler launches the start-up program.
The display shows F XX: Software version
The display shows P XX: Parameter version
- The boiler will begin an automatic venting-programm (which lasts
approx. 3 minutes) and will do this every time the power supply is
isolated. The version numbers are displayed alternately.
- The display shows :
- 1: Ventilation
- 2: Ignition
- 4: Only domestic hot water operating
- 7: Boiler pump operating for DHW heating
- 0: The boiler goes into standby mode
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
19
Maintenance and periodic checks
- Open and close the radiator valves several times a year (this
prevents the valves from seizing up).
- Checking the hydraulic pressure. Insufficient pressure: add water
(1.5 - 2 bar).
- Clean the outside of the boiler using a damp cloth and a light
detergent.
and cleaning of the heater must be carried out
Maintenance
at least once a year by a qualified technician.
We recommend taking out a maintenance contract.
- Carry out a visual check for the presence of any water leaks.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
20
Warranty
You have just purchased one of our appliances and we thank you
for the trust you have placed in our products.
France
Please note that your appliance will provide good service for a
longer period of time if it is regularly checked and maintained.
The preceding dispositions are not exclusive of benefits for the
purchaser of the legal guarantee as stated in Civil Code articles
1641 to 1648.
Your fitter and our customer support network are at your disposal
at all times.
Belgium
Warranty terms
The preceding dispositions about the contractual guarantee are
not exclusive of profit if the need arises for the purchaser in
Belgium of the applicable legal dispositions on hidden defects.
Starting from the purchase date shown on the original fitter's
invoice, your appliance has a contractual guarantee against any
manufacturing defect.
The length of the guarantee is mentioned in the price catalogue.
The manufacturer is not liable for any improper use of the
appliance or failure to maintain or install the unit correctly (the
user shall take care to ensure that the system is installed by a
qualified fitter).
In particular, the manufacturer shall not be held responsible for
any damage, loss or injury caused by installations which do not
comply with the following:
Switzerland
The application of the warranty is subject to the terms and
conditions of sale, delivery and warranty of the company
marketing our products.
Other countries
The above provisions do not restrict the benefit of the legal laws
regarding hidden defects applicable in the buyer's country.
- applicable local laws and regulations
- specific requirements relating to the installation, such as
national and/or local regulations
- the manufacturer's instructions, in particular those relating to
the regular maintenance of the unit
- the rules of the profession
The warranty is limited to the exchange or repair of such parts as
have been recognised to be faulty by our technical department
and does not cover labour, travel and carriage costs.
The warranty shall not apply to the replacement or repair of parts
damaged by normal wear and tear, negligence, repairs by
unqualified parties, faulty or insufficient monitoring and
maintenance, faulty power supply or the use of unsuitable fuel.
Sub-assemblies such as motors, pumps, electric valves etc. are
guaranteed only if they have never been dismantled.
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
21
22
MCR 24, 24/28MI, 30/35MI, 34/39MI
08/06/06 - 300008487-001-A
08/06/06 - 300008487-001-A
MCR 24, 24/28MI, 30/35MI, 34/39MI
23
DE DIETRICH HEIZTECHNIK
www.dedietrich.com
DE DIETRICH THERMIQUE S.A.S.
www.dedietrich.com
In the interest of customers, De Dietrich Thermique SAS are continuously endeavouring to make improvements in product quality. All the specifications stated in this document are therefore subject to change without notice
FR
Direction des Ventes France
57, rue de la Gare
F- 67580 MERTZWILLER
+33 (0)3 88 80 27 00
+33 (0)3 88 80 27 99
AT
NEUBERG S.A.
www.dedietrich.com
DE DIETRICH HEIZTECHNIK
www.dedietrich.com
DE
Rheiner Strasse 151
D- 48282 EMSDETTEN
+49 (0)25 72 / 23-5
+49 (0)25 72 / 23-102
info@dedietrich.de
LU
VAN MARCKE
www.vanmarcke.be
BE
Weggevoerdenlaan 5
B- 8500 KORTRIJK
+32 (0)56/23 75 11
AD001Z • 02.2006
Z.I de la Veyre, St-Légier
1800 VEVEY 1
+41 (0)21 943 02 22
+41 (0)21 943 02 33
39 rue Jacques Stas
L- 2010 LUXEMBOURG
+352 (0)2 401 401
DE DIETRICH
www.dedietrich.com
RU
VESCAL S.A.
www.chauffer.ch / www.heizen.ch
CH
Am Concorde Park 1 - B 4 / 28
A-2320 SCHWECHAT / WIEN
+43 (0)1 / 706 40 60-0
+43 (0)1 / 706 40 60-99
office@dedietrich.at
8 Gilyarovskogo Str. 7
R- 129090 MOSCOW
+7 495.974.16.03
+7 495.974.66.08
dedietrich@nnt.ru
DE DIETRICH
www.dedietrich.com
CN
Room 512, Tower A, Kelun Building
12A Guanghua Rd, Chaoyang District
C-100020 BEIJING
+86 (0)106.581.4017
+86 (0)106.581.4018
+86 (0)106.581.7056
+86 (0)106.581.4019
contactBJ@dedietrich.com.cn