Ultra-Sense - Interline Brands

Ultra-Sense™
Lavatory Faucet S-6080
Battery Powered, Sensor-Activated
Installation, Operation & Service Brief

Tools & Materials
Model Numbers
Need Help?
Symmons customer service:
(800) 796-6667, (781) 848-2250
Email: customerservice@symmons.com
Monday - Friday 7:30 am - 7:00 pm EST
■ S-6080.......Sensor Faucet
Faucet Part # SF-244
■ S-6080-G...Sensor Faucet with
grid strainer drain assembly
2.5 mm
(included)
 www.symmons.com/service
■ Technical help
■ Product information
■ Warranty policy
Quick Install Guide Ultra-Sense Lavatory Faucet, S-6080
Faucet Part Number SF-244
Operation
(sensor activated)
Single hole mount
Step 1
Attach faucet
to deck
finished deck
front view
Temperature
adjust
Step 2
Connect power and
water supply lines
Step 3
Test and check
for leaks
Hot & Cold
supply inputs
Faucet supply configuration options
Three hole mount
with deck plate
Step 1
Attach faucet and
deck plate to deck
1) Temperature adjust
using lever handle
(factory configured)
finished deck
front view
Step 2
Connect power and
water supply lines
Step 3
Test and check
for leaks
Hot & Cold
supply inputs
2) Tempered water
preset internally
(field modified)
3) External premixed
water supply with
single supply input
(field modified)
Installation Instructions
Important! Prior to connecting the water supply, ensure
supply lines are flushed. Particles can clog filter and result in
malfunction. Excessive particles from supply lines may require
installing a separate efficient filter.
Step 1
Step 2 Connect water supply line
Attach faucet to deck (1 hole)
Single hole mount without deck plate
servicing strainer
check
strainer
OFF
finished deck
front view
OFF
Step 3 Modify faucet for preset tempered hot
cold supply (Config option #2)
■ Remove temperature control handle and limit stop.
■ Re-insert handle to adjust supply temperature.
■ Remove handle and replace with push plug.
Step 1 Attach faucet to deck (3 hole)
Step 4 Modify faucet for single supply with
pre-mixed water (Config option #3)
■ Turn temperature control handle counter clockwise
to the maximum cold position.
■ Remove temperature control handle and replace
with push in plug.
■ Remove the flexible hot water supply hose from
base of faucet. (Note: left hand thread)
■ Screw plug in place of supply hose into base of
faucet.
■ Attach single cold supply hose to pre-mixed supply.
Three hole mount with deck plate
Step 5 Test operation and check for leaks
finished deck
front view
HOT
COLD
Page 2
Limiting water temperature
Using Temperature adjustment handle
■ Remove temperature adjustment handle.
■ Set maximum water temperature limit by turning handle
limit stop clockwise (CW).
■ Increase maximum water temperature by turning handle
limit stop counter clockwise (CCW).
■ Re-install temperature adjustment handle.
Adjusting preset water temperature (config #2)
■ Remove temperature adjustment handle plug.
■ Adjust the maximum water temperature limit by inserting
handle into faucet and turning counter clockwise (CCW).
■ Increase temperature by turning handle clockwise (CW).
■ Remove handle and re-install plug.
Troubleshooting
Sensor eye is blinking
■ Indicates battery is weak and needs to be replaced.
No water flow
■
■
■
■
■
Check water supply to the faucet.
Clean around photo cell sensor area.
Check for loose battery connections.
Replace the solenoid valve.
Replace the sensor.
Water flow is weak
■ Water supply stops are not fully open.
■ Clean aerator and check strainer on end of supply line(s).
Excessive clogging may require installing of separate
efficient filter into supply line.
Water flow from spout fails to turn off
■ Sensing range may be too low. Clean around photo cell
sensor area.
■ Clean solenoid valve membrane or replace solenoid valve.
Water temperature can’t be adjusted
■ Clean the check strainer on end of supply line(s).
■ Clean or replace the mixer.
Operation
Faucet care
Sensor recognition range is factory
preset at 1/2 - 4 inches
Place hand under faucet, water will flow
automatically for 10 seconds and shut off.
Cleaning surface finish
Auto shut-off time is factory preset
at 1/2 to 1 second
Remove hands, water will stop automatically
within 1/2 to 1 second.
Precautions
Security OFF after 10 seconds
Faucet will automatically shut off after
continuous water flow for 10 seconds.
Weak or dead battery
LED will flash to signal battery is getting
weak and should be replaced soon.
■ Block sensor with plastic cleaning cover to prevent faucet from
turning on while cleaning.
■ Clean finish area by using mild soap and water or nonabrasive cleaner and then rinse immediately. A nonabrasive wax may be used to preserve finish area.
■ Ensure sensor is not damaged through impact or scratches.
■ Ensure sensor is not blocked or disturbed by any object
with its detection range.
■ Ensure that no strong light source is aimed directly at
sensor or through a mirror.
Risk of Freezing
When installing the faucet in a location where the temperature
may fall below freezing, the entire system must be drained of
water to prevent damage in freezing weather.
■ Turn off water supply.
■ Disconnect all flexible hoses.
■ Drain all parts and hoses of water.
Page 3
Dimensions Ultra-Sense Lavatory Faucet, S-6080
Model S-6080, p/n SF-244
Note
(1) Faucet shown with 4 inch
centered deck plate.
(2) Dimensions subject to
change without notice.
Deck plate, 6" (152 mm)
Temperature
adjust
Deck plate
2-1/2"
(64 mm)
Hole diameter
1-5/16" - 1-3/8"
(33 mm - 35 mm)
1/4"-20 UNC
4" (102 mm)
Strainer/adapters,
3/8" compression
spacer
1/2" (13 mm)
with spacer
1-1/8" (29 mm)
without spacer
5-5/16"
(135 mm)
º
9
1
4-7/16"
(112 mm)
19"
(483 mm)
Parts Assembly Ultra-Sense Lavatory Faucet, S-6080
Faucet Part Number SF-244
aerator
1.5 gpm
removal key
S-6080 Replacement Parts
2.5 mm wrench
(included)
Battery casing
SF-2CR5
6v lithium battery, 2CR5
with removal paddle
SF-240
Solenoid valve
with removal tool
SF-245
Sensor and
retainer
removal tool
SF-186
solenoid valve
mixer adjust
screw
temperature
adjust handle
Check / strainer kit housing
for flex hose
check
connections
screen
SF-158
Single hole
mounting kit
battery casing
sensor
removal paddle
sensor
retainer
battery
solenoid
power
connector
power
connector
holder
valve body
u-washer
mixing plug
hex nut
retainer
flex hose
SF-125
Aerator, vandal resistant
with removal key #LL-60K
■ 1.5 gpm (5.7 L/min)
LN-100
LN-217
Non-aerated laminar flow
vandal resistant spray outlet
with removal key #LL-60K
■ 0.5 gpm (1.9 L/min)
■ 1.5 gpm (5.7 L/min)
check/strainer adapter
3/8" compression
Deck plate assembly
deck plate
gasket
bracket
body
fastener
screw
Item
SF-241
body fastener
screw
faucet body
Part Number
mounting
stud
spacer
nut
Ordering replacement parts:
Call Symmons customer service at (800) 796-6667,
(781) 848-2250 M-F 7:30 am - 7:00 pm EST or
check our website at www.symmons.com for a
list of Symmons distributors.
Symmons Industries, Inc. 31 Brooks Drive ■ Braintree, MA 02184 ■ ©2014 Symmons Industries, Inc. Printed in U.S.A.
Phone: (800) 796-6667 ■ Fax: (800) 961-9621, (781)664-1300 ■ www.symmons.com ■ customerservice@symmons.com
Model# S-6080 ■ Part# SF-244 ■ Document #ZV-1017 ■ RevDate 123014