COMe-bBD6
Doc. Rev. 1.4
USER GUIDE
COMe-bBD6 User Guide Rev. 1.4
This page has been intentionally left blank
www.kontron.com
// 2
COMe-bBD6 User Guide Rev. 1.4

COME-BBD6 USER GUIDE
Disclaimer
Kontron would like to point out that the information contained in this manual may be subject to alteration,
particularly as a result of the constant upgrading of Kontron products. This document does not entail any guarantee
on the part of Kontron with respect to technical processes described in the manual or any product characteristics set
out in the manual. Kontron assumes no responsibility or liability for the use of the described product(s), conveys no
license or title under any patent, copyright or mask work rights to these products and makes no representations or
warranties that these products are free from patent, copyright or mask work right infringement unless otherwise
specified. Applications that are described in this manual are for illustration purposes only. Kontron makes no
representation or warranty that such application will be suitable for the specified use without further testing or
modification. Kontron expressly informs the user that this manual only contains a general description of processes and
instructions which may not be applicable in every individual case. In cases of doubt, please contact Kontron.
This manual is protected by copyright. All rights are reserved by Kontron. No part of this document may be
reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer
language, in any form or by any means (electronic, mechanical, photocopying, recording, or otherwise), without the
express written permission of Kontron. Kontron points out that the information contained in this manual is constantly
being updated in line with the technical alterations and improvements made by Kontron to the products and thus this
manual only reflects the technical status of the products by Kontron at the time of publishing.
Brand and product names are trademarks or registered trademarks of their respective owners.
© 2016, 2017 by Kontron AG
Kontron AG
Lise-Meitner-Str. 3-5
86156 Augsburg
Germany
www.kontron.com
www.kontron.com
// 3
COMe-bBD6 User Guide Rev. 1.4
High Risk Applications Hazard Notice
THIS DEVICE AND ASSOCIATED SOFTWARE ARE NOT DESIGNED, MANUFACTURED OR INTENDED FOR USE
OR RESALE FOR THE OPERATION OF NUCLEAR FACILITIES, THE NAVIGATION, CONTROL OR
COMMUNICATION SYSTEMS FOR AIRCRAFT OR OTHER TRANSPORTATION, AIR TRAFFIC CONTROL, LIFE
SUPPORT OR LIFE SUSTAINING APPLICATIONS, WEAPONS SYSTEMS, OR ANY OTHER APPLICATION IN A
HAZARDOUS ENVIRONMENT, OR REQUIRING FAIL-SAFE PERFORMANCE, OR IN WHICH THE FAILURE OF
PRODUCTS COULD LEAD DIRECTLY TO DEATH, PERSONAL INJURY, OR SEVERE PHYSICAL OR
ENVIRONMENTAL DAMAGE (COLLECTIVELY, "HIGH RISK APPLICATIONS").
You understand and agree that your use of Kontron devices as a component in High Risk Applications is entirely at
your risk. To minimize the risks associated with your products and applications, you should provide adequate design
and operating safeguards. You are solely responsible for compliance with all legal, regulatory, safety, and security
related requirements concerning your products. You are responsible to ensure that your systems (and any Kontron
hardware or software components incorporated in your systems) meet all applicable requirements. Unless otherwise
stated in the product documentation, the Kontron device is not provided with error-tolerance capabilities and cannot
therefore be deemed as being engineered, manufactured or setup to be compliant for implementation or for resale as
device in High Risk Applications. All application and safety related information in this document (including application
descriptions, suggested safety measures, suggested Kontron products, and other materials) is provided for reference
only.
www.kontron.com
// 4
COMe-bBD6 User Guide Rev. 1.4
Revision History
Revision
Brief Description of Changes
Date of Issue
1.0
Initial issue
2016-May-26
1.1
Figure 5 and 7 updated, table 4 corrected
2016-July-21
1.2
Table 16 updated with new part numbers for memory modules
2016-August-05
1.3
Table 39 updated: C29 and C30 description corrected
2016-August-18
1.4
Legal and service information updated; table 16: Table header corrected and memory part 2017-February-18
numbers replaced by speaking P/Ns
Terms and Conditions
Kontron warrants products in accordance with defined regional warranty periods. For more information about
warranty compliance and conformity, and the warranty period in your region, visit http://www.kontron.com/termsand-conditions.
Kontron sells products worldwide and declares regional General Terms & Conditions of Sale, and Purchase Order
Terms & Conditions. Visit http://www.kontron.com/terms-and-conditions.
For contact information, refer to the corporate offices contact information on the last page of this user guide or visit
our website CONTACT US.
Customer Support
Find Kontron contacts by visiting: http://www.kontron.com/support.
Customer Service
As a trusted technology innovator and global solutions provider, Kontron extends its embedded market strengths into
a services portfolio allowing companies to break the barriers of traditional product lifecycles. Proven product expertise
coupled with collaborative and highly-experienced support enables Kontron to provide exceptional peace of mind to
build and maintain successful products.
For more details on Kontron’s service offerings such as: enhanced repair services, extended warranty, Kontron training
academy, and more visit http://www.kontron.com/support-and-services/services.
Customer Comments
If you have any difficulties using this user guide, discover an error, or just want to provide some feedback, contact
Kontron support. Detail any errors you find. We will correct the errors or problems as soon as possible and post the
revised user guide on our website.
www.kontron.com
// 5
COMe-bBD6 User Guide Rev. 1.4
Symbols
The following symbols may be used in this manual
DANGER indicates a hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided,
may result in minor or moderate injury.
NOTICE indicates a property damage message.
Electric Shock!
This symbol and title warn of hazards due to electrical shocks (> 60 V) when touching products or parts
of them. Failure to observe the precautions indicated and/or prescribed by the law may endanger your
life/health and/or result in damage to your material.
Please refer also to the "High-Voltage Safety Instructions" portion below in this section.
ESD Sensitive Device!
This symbol and title inform that the electronic boards and their components are sensitive to static
electricity. Care must therefore be taken during all handling operations and inspections of this product
in order to ensure product integrity at all times.
HOT Surface!
Do NOT touch! Allow to cool before servicing.
This symbol indicates general information about the product and the user manual.
This symbol also indicates detail information about the specific product configuration.
This symbol precedes helpful hints and tips for daily use.
www.kontron.com
// 6
COMe-bBD6 User Guide Rev. 1.4
For Your Safety
Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its
compliance with electrical safety requirements. It was also designed for a long fault-free life. However, the life
expectancy of your product can be drastically reduced by improper treatment during unpacking and installation.
Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are
requested to conform with the following guidelines.
High Voltage Safety Instructions
As a precaution and in case of danger, the power connector must be easily accessible. The power connector is the
product’s main disconnect device.
Warning
All operations on this product must be carried out by sufficiently skilled personnel only.
Electric Shock!
Before installing a non hot-swappable Kontron product into a system always ensure that your
mains power is switched off. This also applies to the installation of piggybacks. Serious
electrical shock hazards can exist during all installation, repair, and maintenance operations
on this product. Therefore, always unplug the power cable and any other cables which
provide external voltages before performing any work on this product.
Earth ground connection to vehicle’s chassis or a central grounding point shall remain
connected. The earth ground cable shall be the last cable to be disconnected or the first
cable to be connected when performing installation or removal procedures on this product.
Special Handling and Unpacking Instruction
ESD Sensitive Device!
Electronic boards and their components are sensitive to static electricity. Therefore, care
must be taken during all handling operations and inspections of this product, in order to
ensure product integrity at all times.
Do not handle this product out of its protective enclosure while it is not used for operational purposes unless it is
otherwise protected.
Whenever possible, unpack or pack this product only at EOS/ESD safe work stations. Where a safe work station is not
guaranteed, it is important for the user to be electrically discharged before touching the product with his/her hands or
tools. This is most easily done by touching a metal part of your system housing.
It is particularly important to observe standard anti-static precautions when changing piggybacks, ROM devices,
jumper settings etc. If the product contains batteries for RTC or memory backup, ensure that the product is not placed
on conductive surfaces, including anti-static plastics or sponges. They can cause short circuits and damage the
batteries or conductive circuits on the product.
www.kontron.com
// 7
COMe-bBD6 User Guide Rev. 1.4
Lithium Battery Precautions
If your product is equipped with a lithium battery, take the following precautions when replacing the battery.
Danger of explosion if the battery is replaced incorrectly.

Replace only with same or equivalent battery type recommended by the manufacturer.

Dispose of used batteries according to the manufacturer’s instructions.
General Instructions on Usage
In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way.
Changes or modifications to the product, that are not explicitly approved by Kontron and described in this
user guide or received from Kontron Support as a special handling instruction, will void your warranty.
This product should only be installed in or connected to systems that fulfill all necessary technical and
specific environmental requirements. This also applies to the operational temperature range of the
specific board version that must not be exceeded. If batteries are present, their temperature restrictions
must be taken into account.
In performing all necessary installation and application operations, only follow the instructions supplied
by the present user guide.
Keep all the original packaging material for future storage or warranty shipments. If it is necessary to
store or ship the product then re-pack it in the same manner as it was delivered.
Special care is necessary when handling or unpacking the product. See Special Handling and Unpacking
Instruction.
Quality and Environmental Management
Kontron aims to deliver reliable high-end products designed and built for quality, and aims to complying with
environmental laws, regulations, and other environmentally oriented requirements. For more information regarding
Kontron’s quality and environmental responsibilities, visit http://www.kontron.com/about-kontron/corporateresponsibility/quality-management.
Disposal and Recycling
Kontron’s products are manufactured to satisfy environmental protection requirements where possible. Many of the
components used are capable of being recycled. Final disposal of this product after its service life must be
accomplished in accordance with applicable country, state, or local laws or regulations.
WEEE Compliance
The Waste Electrical and Electronic Equipment (WEEE) Directive aims to:

Reduce waste arising from electrical and electronic equipment (EEE)

Make producers of EEE responsible for the environmental impact of their products, especially when the product
become waste
www.kontron.com
// 8
COMe-bBD6 User Guide Rev. 1.4

Encourage separate collection and subsequent treatment, reuse, recovery, recycling and sound environmental
disposal of EEE

Improve the environmental performance of all those involved during the lifecycle of EEE
Environmental protection is a high priority with Kontron.
Kontron follows the WEEE directive
You are encouraged to return our products for proper disposal.
www.kontron.com
// 9
Table of Contents
COMe-bBD6 User Guide Rev. 1.4
1/
Introduction .............................................................................................................................................................19
1.1
Product Description .................................................................................................................................................19
1.2
Product Naming Clarification ..................................................................................................................................19
1.3
Understanding COM Express® Functionality ..........................................................................................................19
1.4
COM Express® Documentation ...............................................................................................................................20
1.5
COM Express® Benefits............................................................................................................................................20
2/
Product Specification ...............................................................................................................................................21
2.1
Module Definition ....................................................................................................................................................21
2.1.1 Commercial Grade Modules....................................................................................................................................21
2.1.2 Industrial Temperature Grade Modules .................................................................................................................21
2.2
Functional Specification...........................................................................................................................................22
2.2.1 Processor ..................................................................................................................................................................22
2.2.2 Chipset ......................................................................................................................................................................24
2.2.3 Storage......................................................................................................................................................................24
2.2.4 USB............................................................................................................................................................................25
2.2.5 PCI Express Configuration........................................................................................................................................25
2.2.6 Ethernet ....................................................................................................................................................................27
2.2.7 Misc Interfaces and Features ..................................................................................................................................29
2.2.8 Kontron Features .....................................................................................................................................................29
2.2.9 Additional Features ..................................................................................................................................................29
2.2.10 Power Features ........................................................................................................................................................30
2.3
Block Diagram COMe-bBD6 .....................................................................................................................................30
2.4
Accessories ...............................................................................................................................................................31
2.4.1 Product Specific Accessories ...................................................................................................................................31
2.4.2 General Accessories .................................................................................................................................................31
2.5
Electrical Specification .............................................................................................................................................32
2.5.1 Supply Voltage..........................................................................................................................................................32
2.5.2 Power Supply Rise Time ...........................................................................................................................................32
2.5.3 Supply Voltage Ripple ..............................................................................................................................................32
2.5.4 Power Consumption ................................................................................................................................................32
2.5.5 ATX Mode .................................................................................................................................................................33
2.5.6 Single Supply Mode..................................................................................................................................................33
2.6
Power Control ..........................................................................................................................................................33
2.6.1 Power Supply............................................................................................................................................................33
2.6.2 Power Button (PWRBTN#) .......................................................................................................................................34
2.6.3 Power Good (PWR_OK) ...........................................................................................................................................34
2.6.4 Reset Button (SYS_RESET# Signal) ..........................................................................................................................34
2.6.5 SM-Bus Alert (SMB_ALERT#) ...................................................................................................................................34
2.7
Environmental Specification ....................................................................................................................................35
2.7.1 Temperature Specification ......................................................................................................................................35
2.7.2 Operating with Kontron heatspreader plate assembly..........................................................................................35
2.7.3 Operating without Kontron heatspreader plate assembly ....................................................................................35
2.7.4 Humidity ...................................................................................................................................................................35
www.kontron.com
// 10
COMe-bBD6 User Guide Rev. 1.4
2.8
Standards and Certifications ...................................................................................................................................35
2.8.1 RoHS II.......................................................................................................................................................................35
2.8.2 Component Recognition UL 60950-1......................................................................................................................36
2.8.3 WEEE Directive .........................................................................................................................................................36
2.8.4 Conformal Coating ...................................................................................................................................................36
2.8.5 Shock & Vibration ....................................................................................................................................................36
2.8.6 EMC...........................................................................................................................................................................36
2.9
MTBF .........................................................................................................................................................................37
2.10
Mechanical Specification .........................................................................................................................................37
2.10.1 Dimension.................................................................................................................................................................37
2.10.2 Height .......................................................................................................................................................................38
2.11
Thermal Management, Heatspreader and Cooling Solutions ...............................................................................39
2.12
Onboard Fan Connector ..........................................................................................................................................39
2.13
Onboard Test Connector .........................................................................................................................................41
3/
Features and Interfaces ...........................................................................................................................................42
3.1
S5 Eco Mode.............................................................................................................................................................42
3.2
Rapid Shutdown .......................................................................................................................................................42
3.2.1 Overview...................................................................................................................................................................42
3.2.2 Crowbar implementation details ............................................................................................................................42
3.3
LPC ............................................................................................................................................................................43
3.4
Serial Peripheral Interface (SPI)...............................................................................................................................43
3.5
SPI boot.....................................................................................................................................................................43
3.5.1 Using an external SPI flash.......................................................................................................................................44
3.5.2 External SPI flash on Modules with Intel® ME ........................................................................................................46
3.6
M.A.R.S. ....................................................................................................................................................................46
3.7
UART .........................................................................................................................................................................47
3.8
Fast I2C .....................................................................................................................................................................48
3.9
GPIO - General Purpose Input and Output .............................................................................................................48
3.10
Triple Staged Watchdog Timer ................................................................................................................................49
3.10.1 Basics ........................................................................................................................................................................49
3.10.2 WDT Signal ...............................................................................................................................................................49
3.11
Intel® Fast Flash Standby™ / Rapid Start Technology™ .........................................................................................50
3.11.1 Requirements ...........................................................................................................................................................50
3.12
Speedstep Technology .............................................................................................................................................51
3.13
C-States .....................................................................................................................................................................51
3.14
Hyper Threading.......................................................................................................................................................52
3.15
ACPI Suspend Modes and Resume Events .............................................................................................................52
4/
System Resources ....................................................................................................................................................54
4.1
Interrupt Request (IRQ) Lines ..................................................................................................................................54
4.2
Memory Area ...........................................................................................................................................................54
4.3
I/O Address Map ......................................................................................................................................................55
4.4
Peripheral Component Interconnect (PCI) Devices ...............................................................................................55
4.5
I2C Bus ......................................................................................................................................................................57
4.6
System Management (SM) Bus ...............................................................................................................................57
5/
Pin-out List ................................................................................................................................................................58
www.kontron.com
// 11
COMe-bBD6 User Guide Rev. 1.4
5.1
Connector X1A Row A ..............................................................................................................................................59
5.2
Connector X1A Row B ..............................................................................................................................................63
5.3
Connector X1B Row C ..............................................................................................................................................67
5.4
Connector X1B Row D ..............................................................................................................................................71
6/
BIOS Operation.........................................................................................................................................................75
6.1
Determining the BIOS Version.................................................................................................................................75
6.2
BIOS Update .............................................................................................................................................................75
6.3
Setup Guide ..............................................................................................................................................................76
6.4
POST Codes ..............................................................................................................................................................76
6.4.1 Start AMI® Aptio Setup Utility .................................................................................................................................76
6.5
BIOS Setup ................................................................................................................................................................78
6.5.1 Main ..........................................................................................................................................................................78
6.5.2 Advanced ..................................................................................................................................................................80
6.5.3 Intel RC Setup ........................................................................................................................................................ 115
6.5.4 Security .................................................................................................................................................................. 198
6.5.5 Boot ....................................................................................................................................................................... 201
6.5.6 Event Logs ............................................................................................................................................................. 203
6.5.7 Save & Exit ............................................................................................................................................................. 206
www.kontron.com
// 12
COMe-bBD6 User Guide Rev. 1.4
List of Tables
Table 1: Pin Assignment ......................................................................................................................................................19
Table 2: Commercial Grade Modules (0°C to 60°C operating)..........................................................................................21
Table 3: Industrial Temperature Grade Modules by Design (E2, -40°C to 85°C Operating) ............................................21
Table 4: Intel® Xeon® Processor D-1500 Product Family Specifications ..........................................................................23
Table 5: Memory Features ..................................................................................................................................................24
Table 6: PCH Features..........................................................................................................................................................24
Table 7: Storage Features ....................................................................................................................................................24
Table 8: USB Features ..........................................................................................................................................................25
Table 9: PCIe Gen 3 Ports ....................................................................................................................................................26
Table 10: PCIe Gen 2 Ports ..................................................................................................................................................27
Table 11: Ethernet Features ................................................................................................................................................29
Table 12: Misc Interfaces and Features ..............................................................................................................................29
Table 13: Kontron Features .................................................................................................................................................29
Table 14: Power Features ....................................................................................................................................................30
Table 15: Product Specific Accessories List ........................................................................................................................31
Table 16: General Accessories List ......................................................................................................................................31
Table 17: COM Express® connector Electrical Specifications ............................................................................................32
Table 18: ATX Mode.............................................................................................................................................................33
Table 19: Single Supply Mode .............................................................................................................................................33
Table 20: Temperature Specification..................................................................................................................................35
Table 21: Test Specification.................................................................................................................................................35
Table 22: Electrical Characteristics .....................................................................................................................................40
Table 23: Supported BIOS Features ....................................................................................................................................43
Table 24: SPI Boot Pin Configuration ..................................................................................................................................44
Table 25: Supported SPI boot flash types for 8-SOIC package ..........................................................................................44
Table 26: Reserved SM-Bus addresses for Smart Battery Solutions on the carrier .........................................................47
Table 27: GPIO Pins ..............................................................................................................................................................48
Table 28: Time-out events...................................................................................................................................................49
Table 29: Following C-States are defined ...........................................................................................................................52
Table 30: List of Interrupt Requests....................................................................................................................................54
Table 31: Designated Memory Locations ...........................................................................................................................54
Table 32: Designated I/O Port Addresses ...........................................................................................................................55
Table 33: PCI Device list .......................................................................................................................................................56
Table 34: I2C Bus Port Addresses........................................................................................................................................57
Table 35: Designated I/O Port Addresses ...........................................................................................................................57
Table 36: Electrical characteristic .......................................................................................................................................58
Table 37: Connector X1A Row A Pin-out List......................................................................................................................59
Table 38: Connector X1A Row B Pin-out List ......................................................................................................................63
Table 39: Connector X1B Row C Pin-out List ......................................................................................................................67
Table 40: Connector X1B Row D Pin-out List .....................................................................................................................71
Table 41: Key Assignment ...................................................................................................................................................76
Table 42: Important POST codes during boot-up ..............................................................................................................76
Table 43: BIOS Setup Screen Sections ................................................................................................................................76
Table 44: Legend Keys List...................................................................................................................................................77
Table 45: Main Features List ...............................................................................................................................................78
Table 46: Trusted Computing Features List........................................................................................................................82
Table 47: ACPI Settings Features List ..................................................................................................................................83
Table 48: Miscellaneous Features List ................................................................................................................................84
www.kontron.com
// 13
COMe-bBD6 User Guide Rev. 1.4
Table 49: Generic LPC Decode Ranges Features List .........................................................................................................85
Table 50: Smart Battery Configuration Features List .........................................................................................................86
Table 51: Watchdog Features List.......................................................................................................................................88
Table 52: FPD UART Serial Port 1 Configuration Features List ..........................................................................................90
Table 53: FPD UART Serial Port 2 Configuration Features List ..........................................................................................91
Table 54: W83627DHGSEC Serial Port 1 Configuration Features List ...............................................................................93
Table 55: W83627DHGSEC Serial Port 2 Configuration Features List ...............................................................................94
Table 56: W83627DHGSEC Parallel Port Configuration Features List...............................................................................95
Table 57: H/W Monitor Features List .................................................................................................................................96
Table 58: Serial Port Console Redirection Features List ....................................................................................................98
Table 59: Console Redirection Settings Features List ........................................................................................................99
Table 60: Legacy Console Redirection Settings Features List ......................................................................................... 101
Table 61: Out-of-Band Management Console Redirection Settings Features List ........................................................ 102
Table 62: PCI Subsystem Settings Features List .............................................................................................................. 103
Table 63: PCI Express Settings Features List.................................................................................................................... 105
Table 64: PCI Express Gen 2 Settings Features List ......................................................................................................... 107
Table 65: PCI Hot-Plug Settings Features List .................................................................................................................. 109
Table 66: Network Stack Configuration Features List ..................................................................................................... 110
Table 67: CSM Configuration Features List ..................................................................................................................... 111
Table 68: Advanced USB Configuration Features List ..................................................................................................... 114
Table 69: Processor Configuration Features List............................................................................................................. 116
Table 70: CPU Socket Configuration Features List .......................................................................................................... 119
Table 71: Advanced Power Management Configuration Features List ......................................................................... 120
Table 72: CPU P State Control Features List .................................................................................................................... 121
Table 73: XE Ration Limit Features List ............................................................................................................................ 123
Table 74: CPU HWPM State Control Features List .......................................................................................................... 124
Table 75: CPU C State Control Features List.................................................................................................................... 125
Table 76: CPU T State Control Features List .................................................................................................................... 126
Table 77: CPU Thermal Management Features List........................................................................................................ 127
Table 78: Energy Perf BIAS Features List ......................................................................................................................... 129
Table 79: Program PowerCTL_MSR Features List ........................................................................................................... 130
Table 80: Program PPO_CURT_CFG_CTRL_MSR Features List ...................................................................................... 131
Table 81: PSI Config Features List .................................................................................................................................... 132
Table 82: Program CSR_ENTRY_CRITERIA Features List ................................................................................................. 133
Table 83: CPU Advanced PM Turning Features List ........................................................................................................ 134
Table 84: Program CSR_SWLTROVRD Features List ........................................................................................................ 136
Table 85: Program MSR VR_MISC_CONFIG Features List .............................................................................................. 137
Table 86: Program MSR VR_MISC_CONFIG2 Features List ............................................................................................ 138
Table 87: DRAM RAPL Configuration Features List ......................................................................................................... 139
Table 88: Socket RAPL Config Features List ..................................................................................................................... 140
Table 89: Common RefCode Configuration Features List............................................................................................... 142
Table 90: QPI General Configuration Features List ......................................................................................................... 144
Table 91: QPI Per Socket Configuration - CPU Features List .......................................................................................... 148
Table 92: Memory Configuration Features List ............................................................................................................... 149
Table 93: Memory Thermal Features List ........................................................................................................................ 153
Table 94: Memory Power Savings Advanced Options Features List .............................................................................. 154
Table 95: Memory Timings & Voltage Override Features List........................................................................................ 155
Table 96: Memory Map Features List .............................................................................................................................. 156
Table 97: Memory RAS Configuration Features List ....................................................................................................... 157
Table 98: IIO Configuration Features List ........................................................................................................................ 158
www.kontron.com
// 14
COMe-bBD6 User Guide Rev. 1.4
Table 99: IIO0 Configuration Features List ...................................................................................................................... 160
Table 100: Socket 0 PcieD00F0 - Port 0/DMI Features List ............................................................................................ 161
Table 101: Socket 0 PcieD0XFX – Port XX Features List .................................................................................................. 163
Table 102: IOAT Configuration Features List ................................................................................................................... 165
Table 103: IIO General Configuration Features List ........................................................................................................ 166
Table 104: Intel VT for Direct I/O (VT-d) Features List .................................................................................................... 167
Table 105: IIO South Complex Configuration Features List ............................................................................................ 168
Table 106: PHC Devices Features List .............................................................................................................................. 170
Table 107: PCH Express Configuration Features List ...................................................................................................... 172
Table 108: PCH Express Root Port Features List ............................................................................................................. 173
Table 109: PCH SATA Configuration Features List .......................................................................................................... 175
Table 110: SATA Mode Options Features List ................................................................................................................. 177
Table 111: USB Configuration Features List .................................................................................................................... 178
Table 112: Security Configuration Features List ............................................................................................................. 179
Table 113: Azalia Configuration Features List ................................................................................................................. 180
Table 114: Platform Thermal Configuration Features List.............................................................................................. 181
Table 115: Miscellaneous Configuration Features List ................................................................................................... 182
Table 116: Server ME General Configuration Features List ........................................................................................... 185
Table 117: Override ICC Clock Enables Features List ...................................................................................................... 186
Table 118: Override ICC Spectrum Configuration Features List ..................................................................................... 188
Table 119: NM Configuration Features List ..................................................................................................................... 189
Table 120: Server ME Configuration Features List .......................................................................................................... 190
Table 121: Runtime Error Logging Features List ............................................................................................................. 191
Table 122: Whea Settings Features List........................................................................................................................... 192
Table 123: Memory Error Enabling Features List ............................................................................................................ 193
Table 124: IIO Error Enable Features List ........................................................................................................................ 194
Table 125: IIO Coherency Interface Error Enable Features List ..................................................................................... 195
Table 126: PCI/PCI Error Enabling Features List .............................................................................................................. 196
Table 127: Reserved Memory Features List .................................................................................................................... 197
Table 128: Security Features List ..................................................................................................................................... 198
Table 129: Secure Boot menu Features List .................................................................................................................... 199
Table 130: Key Management Features List ..................................................................................................................... 200
Table 131: Boot Features List ........................................................................................................................................... 201
Table 132: Change Smbios Event Log Settings Features List.......................................................................................... 204
Table 133: Save & Exit Features List ................................................................................................................................ 206
Table 134: PICMG COME.0 Signal Terminology .............................................................................................................. 207
www.kontron.com
// 15
COMe-bBD6 User Guide Rev. 1.4
List of Figures
Figure 1: Block Diagram COMe-bBD6 .................................................................................................................................30
Figure 2: RoHS ......................................................................................................................................................................36
Figure 3: Component Recognition UL .................................................................................................................................36
Figure 4: MTBF Temperature De-rating .............................................................................................................................37
Figure 5: Module Dimensions .............................................................................................................................................38
Figure 6: Module Height ......................................................................................................................................................38
Figure 7: Location of the FAN Connectors..........................................................................................................................40
Figure 8: Entering USB Key Partition Name........................................................................................................................45
Figure 9: Using kflash help option.......................................................................................................................................45
Figure 10: Programming the Flash Image Drive .................................................................................................................46
Figure 11: Configuring GPIO Pins using JIDA32/K-Station .................................................................................................48
Figure 12: Main Menu Screen .............................................................................................................................................78
Figure 13: Platform Information Menu Screen ..................................................................................................................79
Figure 14: Advanced Menu Screen .....................................................................................................................................80
Figure 15: iSCSI Configuration Menu Screen......................................................................................................................81
Figure 16: Trusted Computing Menu Screen .....................................................................................................................82
Figure 17: ACPI Settings Menu Screen ...............................................................................................................................83
Figure 18: Miscellaneous Menu Screen .............................................................................................................................84
Figure 19: Generic LPC Decode Ranges Menu Screen .......................................................................................................85
Figure 20: Smart Battery Configuration Menu Screen ......................................................................................................86
Figure 21: Battery Information Menu Screen ....................................................................................................................87
Figure 22: Watchdog Menu Screen ....................................................................................................................................88
Figure 23: FPD UART Super IO Configuration Menu Screen .............................................................................................89
Figure 24: FPD UART Serial Port 1 Configuration Menu Screen........................................................................................90
Figure 25: FPD UART Serial Port 2 Configuration Menu Screen........................................................................................91
Figure 26: W83627DHGSEC Super IO Configuration Menu Screen ..................................................................................92
Figure 27: W83627DHGSEC Serial Port 1 Configuration Menu Screen ............................................................................93
Figure 28: W83627DHGSEC Serial Port 2 Configuration Menu Screen ............................................................................94
Figure 29: W83627DHGSEC Parallel Port Configuration Menu Screen ............................................................................95
Figure 30: H/W Monitor Menu Screen ...............................................................................................................................96
Figure 31: Serial Port Console Redirection Menu Screen ..................................................................................................98
Figure 32: Console Redirection Settings Menu Screen......................................................................................................99
Figure 33: Legacy Console Redirection Settings Menu Screen ...................................................................................... 101
Figure 34: Out-of-Band Management Console Redirection Settings Menu Screen ..................................................... 102
Figure 35: PCI Subsystem Settings Menu Screen ............................................................................................................ 103
Figure 36: PCI Express Settings Menu Screen ................................................................................................................. 105
Figure 37: PCI Express Gen 2 Settings Menu Screen ...................................................................................................... 107
Figure 38: PCI Hot-Plug Settings Menu Screen ............................................................................................................... 109
Figure 39: Network Stack Configuration Menu Screen .................................................................................................. 110
Figure 40: CSM Configuration Menu Screen ................................................................................................................... 111
Figure 41: NVMe Configuration Menu Screen ................................................................................................................ 113
Figure 42: Advanced USB Configuration Menu Screen .................................................................................................. 114
Figure 43: Intel RC Setup Menu Screen ........................................................................................................................... 115
Figure 44: Processor Configuration Menu Screen .......................................................................................................... 116
Figure 45: Pre-Socket Configuration Menu Screen......................................................................................................... 118
Figure 46: CPU Socket Configuration Menu Screen ....................................................................................................... 119
Figure 47: Advanced Power Management Configuration Menu Screen ....................................................................... 120
Figure 48: CPU P State Control Menu Screen ................................................................................................................. 121
www.kontron.com
// 16
COMe-bBD6 User Guide Rev. 1.4
Figure 49: XE Ratio Limit Menu Screen ........................................................................................................................... 123
Figure 50: CPU HWPM State Control Menu Screen........................................................................................................ 124
Figure 51: CPU C State Control Menu Screen ................................................................................................................. 125
Figure 52: CPU T State Control Menu Screen ................................................................................................................. 126
Figure 53: CPU Thermal Management Menu Screen ..................................................................................................... 127
Figure 54: CPU Advanced PM Turning Menu Screen...................................................................................................... 128
Figure 55: Energy Perf BIAS Menu Screen ....................................................................................................................... 129
Figure 56: Program PowerCTL_MSR Menu Screen ......................................................................................................... 130
Figure 57: Program PPO_CURT_CFG_CTRL_MSR Menu Screen .................................................................................... 131
Figure 58: PSI Config Menu Screen .................................................................................................................................. 132
Figure 59: Program CSR_ENTRY_CRITERIA Menu Screen............................................................................................... 133
Figure 60: CPU Advanced PM Turning Menu Screen...................................................................................................... 134
Figure 61: Program CSR_SWLTROVRD Menu Screen ..................................................................................................... 136
Figure 62: Program MSR VR_MISC_CONFIG Menu Screen ............................................................................................ 137
Figure 63: Program MSR VR_MISC_CONFIG2 Menu Screen .......................................................................................... 138
Figure 64: DRAM RAPL Configuration Menu Screen....................................................................................................... 139
Figure 65: Socket RAPL Config Menu Screen .................................................................................................................. 140
Figure 66: Common RefCode Configuration Menu Screen ............................................................................................ 142
Figure 67: QPI Configuration Menu Screen ..................................................................................................................... 143
Figure 68: QPI General Configuration Menu Screen ...................................................................................................... 144
Figure 69: QPI Status Menu Screen ................................................................................................................................. 146
Figure 70: QPI Per Socket Configuration Menu Screen .................................................................................................. 147
Figure 71: QPI Per Socket Configuration - CPU Menu Screen ........................................................................................ 148
Figure 72: Memory Configuration Menu Screen ............................................................................................................ 149
Figure 73: Memory Topology Menu Screen .................................................................................................................... 152
Figure 74: Memory Thermal Menu Screen ..................................................................................................................... 153
Figure 75: Memory Power Savings Advanced Options Menu Screen ............................................................................ 154
Figure 76: Memory Timings & Voltage Override Menu Screen ..................................................................................... 155
Figure 77: Memory Map Menu Screen ........................................................................................................................... 156
Figure 78: Memory RAS Configuration Menu Screen ..................................................................................................... 157
Figure 79: IIO Configuration Menu Screen ...................................................................................................................... 158
Figure 80: IIO0 Configuration Menu Screen .................................................................................................................... 160
Figure 81: Socket 0 PcieD00F0 - Port 0/DMI Menu Screen ............................................................................................ 161
Figure 82: Socket 0 PcieD0XFX – Port XX Menu Screen ................................................................................................. 163
Figure 83: IOAT Configuration Menu Screen .................................................................................................................. 165
Figure 84: IIO General Configuration Menu Screen ........................................................................................................ 166
Figure 85: Intel VT for Directed I/O (VT-d) Menu Screen ............................................................................................... 167
Figure 86: IIO South Complex Configuration Menu Screen............................................................................................ 168
Figure 87: PCH Configuration Menu Screen.................................................................................................................... 169
Figure 88: PCH Devices Menu Screen .............................................................................................................................. 170
Figure 89: PCH Express Configuration Menu Screen ...................................................................................................... 172
Figure 90: PCH Express Root Port Menu Screen ............................................................................................................. 173
Figure 91: PCH SATA Configuration Menu Screen .......................................................................................................... 175
Figure 92: SATA Mode Options Menu Screen ................................................................................................................. 177
Figure 93: USB Configuration Menu Screen .................................................................................................................... 178
Figure 94: Security Configuration Menu Screen ............................................................................................................. 179
Figure 95: Azalia Configuration Menu Screen ................................................................................................................. 180
Figure 96: Platform Thermal Configuration Menu Screen ............................................................................................. 181
Figure 97: Miscellaneous Configuration Menu Screen ................................................................................................... 182
Figure 98: Server ME Debug Configuration Menu Screen.............................................................................................. 184
www.kontron.com
// 17
COMe-bBD6 User Guide Rev. 1.4
Figure 99: Server ME General Configuration Menu Screen ........................................................................................... 185
Figure 100: Override ICC Clock Enables Menu Screen ................................................................................................... 186
Figure 101: Override ICC Spectrum Configuration Menu Screen .................................................................................. 188
Figure 102: NM Configuration Menu Screen .................................................................................................................. 189
Figure 103: Server ME Configuration Menu Screen ....................................................................................................... 190
Figure 104: Runtime Error Logging Menu Screen ........................................................................................................... 191
Figure 105: Whea Settings Menu Screen ........................................................................................................................ 192
Figure 106: Memory Error Enabling Menu Screen ......................................................................................................... 193
Figure 107: IIO Error Enable Menu Screen ...................................................................................................................... 194
Figure 108: IIO Coherency Interface Error Enable Menu Screen ................................................................................... 195
Figure 109: PCI/PCI Error Enabling Menu Screen ........................................................................................................... 196
Figure 110: Reserved Memory Menu Screen.................................................................................................................. 197
Figure 111: Security Menu Screen ................................................................................................................................... 198
Figure 112: Secure Boot menu Menu Screen ................................................................................................................. 199
Figure 113: Key Management Menu Screen ................................................................................................................... 200
Figure 114: Boot Menu Screen ........................................................................................................................................ 201
Figure 115: Event Logs Menu Screen .............................................................................................................................. 203
Figure 116: Change Smbios Event Log Settings Menu Screen ....................................................................................... 204
Figure 117: View Smbios Event Log Menu Screen .......................................................................................................... 205
Figure 118: Save & Exit Menu Screen .............................................................................................................................. 206
www.kontron.com
// 18
COMe-bBD6 User Guide Rev. 1.4
1/ Introduction
1.1
Product Description
Kontron's Computer-on-Module COMe-bBD6 is a COM Express® BASIC TYPE 6 WITH Intel® Xeon® PROCESSOR D-1500
with support for Pin-out Type 6, and an additional communication interface block. Kontron's module covers both the
need for latest interface technology and the need to extend life-time. The Intel® XEON®D1500 Generation increases
efficiency and performance per watt ratio, which is a result of the innovative 14nm technology and has up to 16 cores
for control, micro server, storage and communication applications in Internet of Things (IoT) and embedded
environment. The COMe-bBDi6R is also designed for industrial temperature environment.

Intel® Xeon® Processor D-1500 System on Chip (SoC), newest member of the Intel® Xeon® Processor family

DDR4 memory technology up to 32 GByte ECC, 2x SODIMMs

high-speed connectivity x16 PCIE 3.0 + x8 PCIE2.0, Dual 10GbE interfaces (option)
1.2
Product Naming Clarification
The product names for Kontron COM Express® Computer-on-Modules consist of a short form of the industry standard
(COMe-), the form factor (b=basic, c=compact, m=mini), the capital letters for the CPU and Chipset Codenames (XX)
and the pin-out type (#) followed by the CPU Name.
COM Express® defines a Computer-On-Module, or COM, with all components necessary for a bootable host computer,
packaged as a super component.

COMe-bXX# modules are Kontron's COM Express® modules in basic form factor (125mm x 95mm)

COMe-cXX# modules are Kontron's COM Express® modules in compact form factor (95mm x 95mm)
1.3
Understanding COM Express® Functionality
All Kontron COM Express® basic and compact modules contain two 220pin connectors; each of it has two rows called
Row A & B on primary connector and Row C & D on secondary connector. The COM Express® Computer-On-Module
(COM) features the following maximum amount of interfaces according to the PCI Industrial Computer Manufacturers
Group (PICMG) module Pin-out type.
Table 1: Pin Assignment
Feature
Type 6 Pin-Out
COMe-bBD6 Pin-Out
HD Audio
1x
-
Gbit Ethernet
1x
2x, (the second pin-out is non- standard, see 2.2.6 and 5/)
Serial ATA
4x
4x
Parallel ATA
-
-
PCI
-
-
PCI Express x8
1x
1x
PCI Express x16 (PEG)
1x
1x
USB Client
-
-
USB 2.0
8x
4x
www.kontron.com
// 19
COMe-bBD6 User Guide Rev. 1.4
Feature
Type 6 Pin-Out
COMe-bBD6 Pin-Out
USB 3.0
4x
4x
VGA
1x
Not used
LVDS
Dual Channel
Not used
DP++ (SDVO/DP/HDMI/DVI)
3x
DDI interface used for 2x 10G interface, (the second pinout is non- standard, see 2.2.6 and 5/)
LPC
1x
1x
External SMB
1x
1x
External I2C
1x
1x
GPIO
8x
8x
SDIO shared w/GPIO
1x optional
-
UART (2-wire COM)
2x
2x
FAN PWM out
1x
1x
1.4
COM Express® Documentation
The COM Express® Specification defines the COM Express® module form factor, pin-out, and signals. This document is
available at the PICMG® website by filling out the order form.
1.5
COM Express® Benefits
COM Express® modules are very compact, highly integrated computers. All Kontron COM Express® modules feature a
standardized form factor and a standardized connector layout which carry a specified set of signals. Each COM is
based on the COM Express® specification. This standardization allows designers to create a single-system baseboard
that can accept present and future COM Express® modules.
The baseboard designer can optimize exactly how each of these functions implements physically. Designers can place
connectors precisely where needed for the application on a baseboard designed to optimally fit a system’s packaging.
A single baseboard design can use a range of COM Express® modules with different sizes and pin-outs. This flexibility
can differentiate products at various price/performance points, or when designing future proof systems that have a
built-in upgrade path. The modularity of a COM Express® solution also ensures against obsolescence when computer
technology evolves. A properly designed COM Express® baseboard can work with several successive generations of
COM Express® modules.
A COM Express® baseboard design has many advantages of a customized computer-board design and, additionally,
delivers better obsolescence protection, heavily reduced engineering effort, and faster time to market.
www.kontron.com
// 20
COMe-bBD6 User Guide Rev. 1.4
2/ Product Specification
2.1
Module Definition
The COM Express® basic sized Computer-on-Module COMe-bBD6 (bBD6) follows pin-out Type 6 and is compatible to
PICMG specification COM.0 Rev 2.1. The COMe-bBD6, based on the latest Grangeville platform, is available in different
variants to cover the different demands in performance, price and power.
2.1.1 Commercial Grade Modules
The following is a list of modules for commercial temperature range.
Table 2: Commercial Grade Modules (0°C to 60°C operating)
Product Number
Product Name
Processor
PCH
Memory
TPM
68002-0000-48-8
COMe-bBD6 D-1548
Intel® Xeon®
Processor D-1548
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68002-0000-37-8
COMe-bBD6 D-1537
Intel® Xeon®
Processor D-1537
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68002-0000-28-6
COMe-bBD6 D-1528
Intel® Xeon®
Processor D-1528
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68002-0000-27-4
COMe-bBD6 D-1527
Intel® Xeon®
Processor D-1527
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68002-0000-18-4
COMe-bBD6 D-1518
Intel® Pentium®
Processor D-1518
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68002-0000-17-4
COMe-bBD6 D-1517
Intel® Pentium®
Processor D-1517
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68002-0000-08-4
COMe-bBD6 D-1508
Intel® Xeon®
Processor D-1508
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
2.1.2 Industrial Temperature Grade Modules
Industrial temperature grade modules are available based on their design. Please contact your local sales or support
for further details.
Table 3: Industrial Temperature Grade Modules by Design (E2, -40°C to 85°C Operating)
Product Number
Product Name
Processor
PCH
Memory
TPM
68003-0000-19-4
COMe-bBDi6R D-1519
Intel® Xeon®
Processor D-1519
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68003-0000-39-8
COMe-bBDi6R D-1539
Intel® Xeon®
Processor D-1539
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
68003-0000-59-9
COMe-bBDi6R D-1559
Intel® Xeon®
Processor D-1559
Integrated
2xDDR4-2133
Infineon SLB9665XT 2.0
www.kontron.com
// 21
COMe-bBD6 User Guide Rev. 1.4
2.2
Functional Specification
2.2.1 Processor
The 14nm Intel® Xeon® processor D-1500 product family with 37.5mm x 37.5mm package size (1667 Ball FCBGA)
supports:




Performance
−
Intel® 64
−
Intel® Turbo Boost Technology 2.0
−
Intel® Advanced Vector Extensions 2 (AVX2)
−
Memory Bandwidth Monitoring
Xeon Class Reliability Availability Serviceability (RAS) includes:
−
Error-Correcting Code (ECC) Single Device Data Correction (SDDC),
−
Memory Demand and Patrol Scrubbing,
−
Data Scrambling with address,
−
End-to-end Cyclic Redundancy Check (ECRC) on PCIe,
−
PCIe and GbE Advanced Error Reporting (AER),
−
Intel® Corrected Machine Check Interrupt (CMCI) Virtualization.
Virtualization:
−
Intel® Virtualization Technology (VT-x)
−
Advanced Programmable Interrupt Controller virtualization (APICv)
−
Intel® Virtual Machine Control Structure Shadowing (Intel® VMCS Shadowing)
−
Intel® Virtualization Technology for Directed I/O (VT-d)
−
Extended Page Table Accessed and Dirty bits (A/D bits for EPT)
−
Posted Interrupts,
−
Single-Root Input/Output Virtualization (SR-IOV)
−
VT Cache Quality of Service (QoS) and QoS Monitoring/Enforcement
Security
−
Intel® Trusted Execution Technology (TXT) (requires custom BIOS)
−
Intel® Advanced Encryption Standard New Instructions (AES-NI) (requires custom BIOS)
−
Intel® OS Guard (Supervisor Mode Access Protection (SMAP))
−
Intel® Secure Key (RDSEED)

Intel® Hyper-Threading Technology

Configurable Thermal Design Power (cTDP)

Intel® Thermal Monitoring Technologies

Node Manager Base Power Management (ME FW)
www.kontron.com
// 22
COMe-bBD6 User Guide Rev. 1.4
Table 4 provides a list of processors and specifications of the Intel® Xeon® Processor D-1500 Product Family
compatible with COMe-bBD6.
Table 4: Intel® Xeon® Processor D-1500 Product Family Specifications
Intel® Xeon® D-1548
Processor
D-1537
D-1528
D-1527
D-1518
D-1517
D-1508
D1519
D-1539
D-1559
# of Cores
8
8
6
4
4
4
2
4
8
12
# of Threads
16
16
12
8
8
8
4
8
16
24
Processor
Base
Frequency
2GHz
1,7GHz
1,9GHz
2,2GHz
2,2GHz
2,2GHz
2,2GHz
1,5GHz
1,6GHz
1,5GHz
Max Turbo
Frequency
2,6GHz
2,3GHz
2,4GHz
2,7GHz
2,2GHz
2,6GHz
2,6GHz
TBD
TBD
TBD
eTEMP
eTEMP
eTEMP
Temperature
Thermal
Design
Power (TDP)
45W
35W
35W
35W
35W
25W
25W
25W
35W
45W
Command
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
64Bit
AVX 2.0
Cache
12MB
12MB
9MB
6MB
6MB
6MB
3MB
6MB
12MB
18MB
Memory
Type
DDR4
DDR4
DDR4
DDR4
DDR4
DDR4
DDR4
DDR4
DDR4
DDR4
Max
Memory
Size
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
32GB
(2x16)
ECC Memory Yes
Supported
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
PCIe Express
(COMe PEG)
3.0
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
16x,
4 Contr.
PCIe Lanes
(COMe) 2.0
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
8x,
8 Contr.
10G KR
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
10G Base-T
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1000 Base-T
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
VT-d
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
AES-NI
(optional)
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Table 5 provides a list of memory features.
www.kontron.com
// 23
COMe-bBD6 User Guide Rev. 1.4
Table 5: Memory Features
Socket
2x DDR4 SO-DIMM
Memory Type
DDR4-2133 ECC
Maximum Size
2x16GB
Technology
Dual Channel
2.2.2 Chipset
The integrated Platform Controller Hub (PCH) supports:

PCI Express Revision 3.0

PCI Express Configurations x1, x4, x8

Intel® Virtualization Technology for Directed I/O (VT-d)

Intel® Trusted Execution Technology (TXT)

Intel® Anti-Theft Technology

Intel® Rapid Storage Technology

Intel® Smart Response Technology
Table 6: PCH Features
Feature
PCH
Rapid Storage
YES
USB 3.0
YES
VT-d
YES
TXT
YES (but not supported on COMe-bBD6)
SATA RAID
YES
2.2.3 Storage
Table 7 provides a list of storage features.
Table 7: Storage Features
onboard SSD
64GB NANDrive option*
SD Card support
-
onboard SATA NAND drive support
-
IDE Interface
-
Serial-ATA
4x SATA 6Gb/s
SATA AHCI
NCQ, HotPlug, Staggered Spinup, eSATA, PortMultiplier
* Contact Kontron for more information
www.kontron.com
// 24
COMe-bBD6 User Guide Rev. 1.4
The 6GB/s and staggered spin features are always supported. All other features are supported
if Redundant Array of Independent Disks (RAID) or Advanced Host Controller Interface (AHCI)
is enabled. To configure a RAID enable RAID support in BIOS Chipset/SATA settings, connect at
least two hard drives and enter the RAID Option ROM by pressing 'CTRL'+'I'.
2.2.4 USB
Table 8 provides a list of USB connections supported by COMe-bBD6.
Table 8: USB Features
USB 3.0/2.0
4x USB 3.0/2.0
USB Client
-
Due to its internal configuration, the Intel® Xeon® Processor D-1500 Family chipset only
supports up to 4 USB Hubs.
2.2.5 PCI Express Configuration
The Xeon D-1500 processor has one x16 and one x8 Gen 3 ports from the integrated I/O and one x8 Gen 2 port from
the integrated PCH.
2.2.5.1 Gen 3 PCI-Express Graphic (PEG) port
The x16 PCI Express Graphics (PEG) port is compatible to standard PCI Express (PCIe) devices like Ethernet or RAID
controllers. This port is available on the COMe connector. There are four root ports allowing the COMe-bBD6 to
support the following port configuration:

One port x16 (default)

Two ports x8

One port x8 plus two ports x4

Four ports x4
The configuration can be selected by a BIOS option in the IIO menu, refer to 6.5.3.36 IIO Configuration.
www.kontron.com
// 25
COMe-bBD6 User Guide Rev. 1.4
Table 9: PCIe Gen 3 Ports
Feature
Configuration 0
Configuration 1
Configuration 2
Configuration 3
Lane 0
Lane 1
x4
Lane 2
Lane 3
x8
Lane 4
x8
Lane 5
x4
Lane 6
Lane 7
x16
Lane 8
Lane 9
Lane 10
Lane 11
x4
x4
x4
x4
x8
Lane 12
Lane 13
Lane 14
Lane 15
2.2.5.2 Gen 3 x8 port
This port is used internally on the bBD6 for connecting the two I210-IT Ethernet controllers and it is not available for
the user on the COMe connectors.
2.2.5.3 Gen 2 PCI-Express x8 port
This port is available on the COMe connector. There are eight root ports allowing it to be configured as an 8 x1
interface for connecting up to eight devices. The following configurations are supported by different BIOS binary:

One port x8

One port x4 plus 4 ports x1

Two ports x4
−
Eight ports x1
www.kontron.com
// 26
COMe-bBD6 User Guide Rev. 1.4
−
Table 10: PCIe Gen 2 Ports
Feature
Configuration 0
Configuration 1
Configuration 2
Lane 0
Lane 1
x4
Lane 2
Lane 3
x8
Lane 4
Lane 5
Configuration 4
x1
x1
x1
x1
x1
x1
x1
x1
x1
x4
Lane 6
x4
Configuration 3
Lane 7
x1
x1
x1
x4
x1
x1
x1
x1
Configuration0 is by (default). All other configurations are provided in the BIOS download
package available on EMD Customer Section.
2.2.6 Ethernet
The COMe-bBD6 offers the following Ethernet Controllers:

Two Intel® Ethernet I210 Controllers

One Intel® Dual-Port Ethernet 10GbE Controller
The I210 controller has the following features:



Platform Power Efficiency
−
IEEE 802.3az Energy Efficient Ethernet (EEE)
−
Proxy: ECMA-393 and Windows* logo for proxy offload
Advanced Features:
−
-40 to 85 °C industrial temperature
−
Jumbo frames
−
Interrupt moderation, VLAN support, IP checksum offload
−
PCIe OBFF (Optimized Buffer Flush/Fill) for improved system power management
−
Four transmit and four receive queues
−
RSS and MSI-X to lower CPU utilization in multi-core systems
−
Advanced cable diagnostics, auto MDI-X
−
ECC – error correcting memory in packet buffers
Manageability:
−
Preboot Execution Environment (PXE) and Internet Small Computer System Interface (iSCSI) boot
www.kontron.com
// 27
COMe-bBD6 User Guide Rev. 1.4
For more information on the I210 Controller, refer to the Intel® Ethernet Controller I210
Datasheet.
The 10GbE controller has the following features:



Optimized for Virtualization
−
128 Tx and Rx queues per port
−
SR-IOV (64 VFs), Virtual Machine Device Queues (VMDq) (64 VMs)
−
Simple Virtual Ethernet Port Aggregator (VEPA), Virtual Ethernet Bridge (VEB)
Software Defined Networking:
−
Virtual Extensible LAN (VXLAN),
−
Network Virtualization using Generic Routing Encapsulation (NVGRE) Network Overlays
Broad OS Support and Validation:
−


Windows, VMWare, Linux, and Solaris
Unified networking:
−
Block Storage (iSCSI boot and Fibre Channel over Ethernet (FCoE) Initiator)
−
DCB up to 8 traffic Classes
Adaptive Power Management:
−
IEEE 802.3az EEE
The 10G Ethernet controller supports the following operation modes:


Backplane:
−
10GBASE-KR for GbE backplane applications (IEEE802.3 clause 72)
−
10GBASE-KR FEC (IEEE 802.3 Clause 74)
−
1000BASE-KX for GbE backplane applications (IEEE802.3 clause 70)
−
Auto-negotiation for backplane Ethernet (IEEE 802.3 Clause 73)
10Gb SFP+:
−

An external PHY is needed. For more information, contact Kontron.
10GBASE-T:
−
An external PHY is needed. For more information, contact Kontron. An interposer is available from Kontron to
test this configuration (see Table 15 and 2.13 Onboard Test Connector)
In order to gain access to the 10GbE Controller and second I210 functionalities, an interposer card is required or
specific carrier board support is needed (for more information, contact Kontron). Without an interposer or proper
carrier handling, the second I210 is not visible in the PCI device tree and the 10G controller is shown as a "dummy
device" and is not usable.
For more information on the 10GbE Controller, refer to the Intel® Xeon® Processor D-1500 Product Family, Datasheet
– Volume 4 of 4: Intel® Xeon® Processor D-1500 Product Family LAN Controller.
www.kontron.com
// 28
COMe-bBD6 User Guide Rev. 1.4
Table 11: Ethernet Features
Ethernet
10/100/1000 Mbit
Ethernet controller
Intel® I210
Optional Ethernet Controller
Intel® 10 GbE
2.2.7 Misc Interfaces and Features
Table 12 provides a list of miscellaneous interfaces and features.
Table 12: Misc Interfaces and Features
Supported BIOS Size/Type
16MB SPI
Onboard Hardware Monitor
Nuvoton NCT7802Y
Trusted Platform Module (TPM)
Infineon SLB9665XT2.0
Miscellaneous
2x UART / PWM FAN
2.2.8 Kontron Features
Table 13 provides a list of Kontron features.
Table 13: Kontron Features
External I2C Bus
Fast I2C, MultiMaster capable
M.A.R.S. support
YES
Embedded API
KEAPI3
Custom BIOS Settings / Flash Backup
YES
Watchdog support
Triple Staged
2.2.9 Additional Features

All solid capacitors (aluminum-polymer and ceramic). No tantalum capacitors used.

Optimized RTC Battery monitoring to secure highest longevity

Fast I2C with transfer rates up to 400kHz
www.kontron.com
// 29
COMe-bBD6 User Guide Rev. 1.4
2.2.10 Power Features
Table 14 provides a list of power features.
Table 14: Power Features
Singly Supply Support
YES
Supply Voltage
8.5V - 20V
ACPI
ACPI 4.0
S-States
S0, S4, S5
S5 Eco Mode
YES
Misc Power Management
YES
2.3
Block Diagram COMe-bBD6
Figure 1 displays the block diagram applicable to all COMe-bBD6 modules.
Figure 1: Block Diagram COMe-bBD6
PWR
COMe-bBD6
COMe Basic Pinout Type 6 with
Intel Xeon D-1500 Processor Family
(Broadwell-DE SoC)
PCIe
10G-KR
USB
Other
SATA
1GbE
Standard
Component
DDR4
CHA
Intel Xeon-D SoC
Connector
XDP
Debug Port
OPTION
JTAG
DDR4 SODIMM 2133Mhz ECC 5.2mm H
Support 16GB/Socket, DRx8
(8Gb x 8 DRAM)
2C 15W to 16C 45W
FCBGA 1667
37.5 x 37.5mm
DDR4
CHB
DDR4 SODIMM 2133Mhz ECC 9.2mm H
I2C
TPM 2.0
SMBus
LPC
SPI
10G
P0 P1
BIOS
Flash
SPI
128Mb
PCIe Gen3
x8
x4
x4
PE2[4:7] PE2[0:3]
SPI
LAN
Flash
SPI
Flash
8Mb
SPI
32Mb
Flash
8Mb
LPC
I2C
x1
x1
PCIe
PCIe
PCIe Gen2
x8
x4
x4
PCIe Gen3
x1 x1 x1 x1 x1 x1 x1 x1
x16
PCIE[8:1]
PE1
SPI
SPI 0 1
10G KR**
1GbE
1GbE
GBE1**
GBE0
** Unused DDI pins.
This breaks specification.
1 x8 or
2 x4 or
8 x1
1 x16 or
2 x8 or
(2 x4 + 1 x8) or
4 x4
MNGT I/O
I2C
SER1
I2C
LPC
Debug
Prog Header
JTAG
COM1
COM2
FPGA
XC6SLX4
CSG225
MNGT I/O
Pwr Seq.
HWM
NCT7802Y
FAN2
FAN1
FAN1
3-pins
PCIe [7:0]
PEG [15:0]
SATA
NANDrive
VCC_5V_SBY
3 2 1 0
SATA 3.0
3 2 1 0
USB 3.0
3 2 1 0
USB 2.0
FAN
COM Express Connector AB-CD
COM.0 Spec Rev 2.1, Pinout Type 6
Features not used
SER0
JIDA
S5ECO
EEPROM
Max5435
SMBus
SATA
I210-IT I210-IT
1GbE
1GbE
9x9mm 9x9mm
I2C
JIDA
EEPROM
Integrated
PCH
PECI
SPI
SATA 3.0 USB 3.0 USB 2.0
4 3 2 1 0 6 5 2 1 3 2 1 0
PECI
LPC
VGA/CRT
HDA
LVDS/eDP
USB 2.0
7 6 5 4
RSDOWN
V_BAT
VCC_12V
SMBus
Rapid
Shutdown
Circuit
DC-DC
Regulators
Flash
4Mb
www.kontron.com
SPI
SPI
Local Voltages
// 30
COMe-bBD6 User Guide Rev. 1.4
2.4
Accessories
2.4.1 Product Specific Accessories
Table 15 provides a list of product accessories specific to COMe-bBD6.
Table 15: Product Specific Accessories List
Product Number
Heatspreader and Cooling Solutions
Comment
68002-0000-99-0
HSP COMe-bBD6, thread mounting
4 threaded mounting holes to use 680020000-99-0C05,
Recommended for design in 68002-0000-990C05
68002-0000-99-0C05
HSK COMe-bBD6 active (w/o HSP)
Standard active Cooler for COMe-bBD6 to be
mounted on HSP
68002-0000-99-1
HSP COMe-bBD6, through hole mounting
4 threaded mounting holes to use 380250000-99-0C05
68200-0000-02-1
ADA-Eval-bBD6 2x 10G, 1x1G LAN
COMe-bBD6 Dual 10GBase-T Interposer Card
Interposer Card for COMe-bBD6 based on
Intel® Ethernet Connection X557-AT2, for
Evaluation only
2.4.2 General Accessories
Table 16 provides a list of general accessories applicable to all COMe pin-out Type 6 products.
Table 16: General Accessories List
Product Number
Heatspreader and Cooling Solutions
Project Code
Comment
38114-0000-00-0
COM Express® Reference Carrier Type 6
ADAS
mITX Carrier with 8mm COMe connector
38106-0000-00-0
COM Express® Eval Carrier Type 6
Topanga Canyon
ATX Carrier with 5mm COMe connector
96006-0000-00-2
COMe POST T6
NFCB
POST Code / Debug Card
Product Number
Mounting
Comment
38017-0000-00-5
COMe Mount KIT 5mm 1set
Mounting Kit for 1 module including screws for 5mm connectors
38017-0000-00-0
COMe Mount KIT 8mm 1set
Mounting Kit for 1 module including screws for 8mm connectors
Product Number
Cables
Comment
96079-0000-00-0
KAB-HSP 200mm
Cable adapter to connect FAN to module (COMe basic/compact)
96079-0000-00-2
KAB-HSP 40mm
Cable adapter to connect FAN to module (COMe basic/compact)
Product Number
Memory ECC (validated reference types)
97018-1600-21-2
DDR4-2133 SODIMM 16GB ECC E2
97018-8192-21-2
DDR4-2133 SODIMM 8GB ECC E2
97018-4096-21-2
DDR4-2133 SODIMM 4GB ECC E2
97018-1600-21-0
DDR4-2133 SODIMM 16GB ECC
97018-8192-21-0
DDR4.2133 SODIMM 8GB ECC
97018-4096-21-0
DDR4-2133 SODIMM 4GB ECC
www.kontron.com
// 31
COMe-bBD6 User Guide Rev. 1.4
Product Number
Non ECC
97017-1600-21-2
DDR4-2133 SODIMM 16GB E2
97017-8192-21-2
DDR4-2133 SODIMM 8GB E2
97017-4096-21-2
DDR4-2133 SODIMM 4GB E2
97017-1600-21-0
DDR4-2133 SODIMM 16GB
97017-8192-21-0
DDR4.2133 SODIMM 8GB
97017-4096-21-0
DDR4-2133 SODIMM 4GB
2.5
Electrical Specification
2.5.1 Supply Voltage
Table 17 provides information regarding the supply voltage specified at the COM Express® connector:
Table 17: COM Express® connector Electrical Specifications
VCC
8.5V - 20V
Standby
5V DC +/- 5%
RTC
2.5V - 3.47V

5V Standby voltage is not mandatory for operation.
2.5.2 Power Supply Rise Time

The input voltages should rise from ≤10% of nominal to within the regulation ranges within 0.1ms to 20ms.

There must be a smooth and continuous ramp of each DC input voltage from 10% to 90% of its final set-point
following the ATX specification.
2.5.3 Supply Voltage Ripple
Maximum 100 mV peak to peak 0 – 20 MHz.
2.5.4 Power Consumption
The maximum Power Consumption of the different COMe-bBD6 variants is 35 - 70W (100% CPU load on all cores;
90°C CPU temperature).
For Information on Detailed Power Consumption measurements in all states and benchmarks
for CPU, Graphics and Memory performance, refer to the Application Note KEMAP054 at
EMD Customer Section.
www.kontron.com
// 32
COMe-bBD6 User Guide Rev. 1.4
2.5.5 ATX Mode
By connecting an ATX power supply with VCC and 5VSB, PWR_OK is set to low level and VCC is off. Press the Power
Button to enable the ATX PSU setting PWR_OK to high level and powering on VCC. The ATX PSU is controlled by the
PS_ON# signal which is generated by SUS_S3# through inversion. VCC can be 8.5V - 20V in ATX Mode. On Computeron-Modules supporting a wide range input down to 4.75V the input voltage shall always be higher than 5V Standby
(VCC > 5VSB).
Table 18: ATX Mode
State
PWRBTN#
PWR_OK
V5_StdBy
PS_ON#
VCC
G3
x
x
0V
x
0V
S5
high
low
5V
high
0V
S5 → S0
PWRBTN Event
low → high
5V
high →
0 V→ VCC
S0
high
high
5V
low
VCC
2.5.6 Single Supply Mode
In single supply mode, without 5V standby the module will start automatically when VCC power is connected and
Power Good input is open or at high level (internal PU to 3.3V). PS_ON# is not used in this mode and VCC can be 8.5V 20V.
To power on the module from S5 state press the power button or reconnect VCC. Suspend/Standby States are not
supported in Single Supply Mode.
Table 19: Single Supply Mode
State
PWRBTN#
PWR_OK
V5_StdBy
VCC
G3
0
0
0
0
G3 → S0
high
open / high
OPEN
connecting VCC
S5
high
open / high
OPEN
VCC
S5 → S0
PWRBTN Event
open / high
OPEN
reconnecting VCC
2.6

Signals marked with “x” are not important for the specific power state. There is no
difference if connected or open.

All ground pins have to be tied to the ground plane of the carrier board.

For more information refer to 2.6 Power Control.
Power Control
2.6.1 Power Supply
The COMe-bBD6 supports a power input from 8.5V - 20V. The supply voltage is applied through the VCC pins (VCC) of
the module connector.
www.kontron.com
// 33
COMe-bBD6 User Guide Rev. 1.4
Optionally, 5V +/- 5% can be applied to the V_5V_STBY pins and allows support for wake-up suspend-to-disk and softoff state when the VCC power is removed.
Suspend-to-RAM is not supported by the Xeon D-1500.
2.6.2 Power Button (PWRBTN#)
The power button (Pin B12) is available through the module connector described in the pin-out list. To start the
module using Power Button the PWRBTN# signal must be at least 50ms (50ms ≤ t < 4s, typical 400ms) at low level
(Power Button Event).
Pressing the power button for at least 4seconds will turn off power to the module (Power Button Override).
2.6.3 Power Good (PWR_OK)
The COMe-bBD6 provides an external input for a power-good signal (Pin B24). The implementation of this subsystem
complies with the COM Express® Specification. PWR_OK is internally pulled up to 3.3V and must be high level to
power on the module.

This is typically driven by the ATX power supply PWR_OK signal.

This can be driven low to hold the module from powering up as long as needed. The
carrier needs to release the signal when ready.
2.6.4 Reset Button (SYS_RESET# Signal)
When the SYS_RESET# pin is detected active, it allows the processor to perform a “graceful” reset, by waiting up to 25
ms for the SMBus to go idle before forcing a reset even though activity is still occurring. Once the reset is asserted, it
remains asserted for 5 to 6 ms regardless of whether the SYS_RESET# input remains asserted or not. For more
information, refer to the Intel® Xeon® D-1500 Product Family Datasheet, Vol. 1.
Modules with Intel® Chipset and active Management Engine do not allow to hold the module
in Reset out of S0 for a long time. At about 10s holding the reset button the ME will reboot
the module automatically.
2.6.5 SM-Bus Alert (SMB_ALERT#)
With an external battery manager present and SMB_ALERT# (Pin B15) connected the module always powers on even
if BIOS switch “After Power Fail” is set to “Stay Off”.
www.kontron.com
// 34
COMe-bBD6 User Guide Rev. 1.4
2.7
Environmental Specification
2.7.1 Temperature Specification
Kontron defines following temperature grades for Computer-on-Modules in general. Please see chapter 'Product
Specification' for available temperature grades for the COMe-bBD6.
Table 20: Temperature Specification
Temperature Specification
Operating
Non-operating
Validated Input Voltage
Commercial grade
0°C to +60°C
-30°C to +85°C
VCC: 8.5V - 20V
Extended Temperature (E1)
-25°C to +75°C
-30°C to +85°C
VCC: 12V
Industrial grade by Screening (XT)
-40°C to +85°C
-40°C to +85°C
VCC: 12V
Industrial grade by Design (E2)
-40°C to +85°C
-40°C to +85°C
VCC: 8.5V - 20V
2.7.2 Operating with Kontron heatspreader plate assembly
The operating temperature defines two requirements:

the maximum ambient temperature with ambient being the air surrounding the module,

the maximum measurable temperature on any spot on the heatspreader's surface.
Table 21: Test Specification
Temperature Grade
Validation requirements
Commercial grade
at 60°C HSP temperature the CPU @ 100% load needs to run at nominal frequency
Extended Temperature (E1)
at 75°C HSP temperature the CPU @ 75% load is allowed to start speedstepping for thermal protection
Industrial grade by Screening (XT)
at 85°C HSP temperature the CPU @ 50% load is allowed to start throttling for thermal protection
Industrial grade by Design (E2)
at 85°C HSP temperature the CPU @ 50% load is allowed to start throttling for thermal protection
2.7.3 Operating without Kontron heatspreader plate assembly
The operating temperature is the maximum measurable temperature on any spot on the module's surface.
2.7.4 Humidity
Relative Humidity at 40°C is 93%, non-condensing (according to IEC 60068-2-78).
2.8
Standards and Certifications
2.8.1 RoHS II
The COMe-bBD6 is compliant to the directive 2011/65/EU on the Restriction of the use of certain Hazardous
Substances (RoHS II) in electrical and electronic equipment.
www.kontron.com
// 35
COMe-bBD6 User Guide Rev. 1.4
Figure 2: RoHS
2.8.2 Component Recognition UL 60950-1
The COM Express® basic form factor Computer-on-Modules are Recognized by Underwriters Laboratories Inc.
Representative samples of this component have been evaluated by UL and meet applicable UL requirements.
UL Listings:

NWGQ2.E304278

NWGQ8.E304278
Figure 3: Component Recognition UL
2.8.3 WEEE Directive
WEEE Directive 2002/96/EC is not applicable for Computer-on-Modules.
2.8.4 Conformal Coating
Conformal Coating is available for Kontron Computer-on-Modules and for validated SO-DIMM memory modules.
Please contact your local sales or support for further details.
2.8.5 Shock & Vibration
The COM Express® basic form factor Computer-on-Modules successfully passed shock and vibration tests according
to:

IEC/EN 60068-2-6 (Non operating Vibration, sinusoidal, 10Hz-4000Hz, +/-0.15mm, 2g)

IEC/EN 60068-2-27 (Non operating Shock Test, half-sinusoidal, 11ms, 15g)
2.8.6 EMC
Validated in Kontron reference housing for EMC the COMe-bBD6 follows the requirements for electromagnetic
compatibility standards:

EN55022

EN55024

2004/108/EC

FCC Part 15
www.kontron.com
// 36
COMe-bBD6 User Guide Rev. 1.4
2.9
MTBF
The following MTBF (Mean Time Before Failure) values were calculated using a combination of manufacturer’s test
data, if the data was available, and the Telcordia (Bellcore) issue 2 calculation for the remaining parts.
The Telcordia calculation used is “Method 1 Case 3” in a ground benign, controlled environment (GB,GC). This
particular method takes into account varying temperature and stress data and the system is assumed to have not
been burned in.
Figure 4 shows MTBF de-rating for the E1 temperature range in an office or telecommunications environment. Other
environmental stresses (such as extreme altitude, vibration, salt water exposure) lower MTBF values.
System MTBF(hours) = 117841 @ 30°C
Figure 4: MTBF Temperature De-rating
250000
197377
200000
182818
168652
154992
141927
MTBF, Predicted
150000
129527
117841
106900
100000
96717
87291
78608
70647
63375
50000
0
0
5
10
15
20
25
30
35
40
45
50
55
60
Temperature
The above estimates assume no fan, but a passive heat sinking arrangement. Estimated RTC
battery life (as opposed to battery failures) is not accounted for in the above figure and
needs to be considered for separately. Battery life depends on both temperature and
operating conditions. When the Kontron unit has external power; the only battery drain is
from leakage paths.
2.10 Mechanical Specification
2.10.1 Dimension
The dimensions of the module (see Figure 5) are 95.0 mm x 125.0 mm.
www.kontron.com
// 37
COMe-bBD6 User Guide Rev. 1.4
Figure 5: Module Dimensions
CAD drawings are available at EMD Customer Section.
2.10.2 Height
The COM Express® specification defines a module height of 13mm from module PCB bottom to heatspreader top (see
Figure 6).
Figure 6: Module Height
Cooling solutions provided from Kontron for basic sized Computer-on-Modules are 27mm in height from module
bottom to Heatsink top.
www.kontron.com
// 38
COMe-bBD6 User Guide Rev. 1.4
Universal Cooling solutions to be mounted on the HSP (36099-0000-00-x) are 14.3mm in height for an overall height
of 27.3mm from module bottom to Heatsink top.
HOT Surface!
Do NOT touch! Allow to cool before servicing.
2.11 Thermal Management, Heatspreader and Cooling Solutions
A heatspreader plate assembly is available from Kontron for the COMe-bBD6. The heatspreader plate on top of this
assembly is NOT a heat sink. It works as a COM Express®-standard thermal interface to use with a heat sink or external
cooling devices.
External cooling must be provided to maintain the heatspreader plate at proper operating temperatures. Under worst
case conditions, the cooling mechanism must maintain an ambient air and heatspreader plate temperature on any
spot of the heatspreader's surface according the module specifications:

60°C for commercial grade modules

75°C for extended temperature grade modules (E1)

85°C for industrial temperature grade modules (E2/XT)
You can use many thermal-management solutions with the heatspreader plates, including active and passive
approaches.
The optimum cooling solution varies, depending on the COM Express® application and environmental conditions.
Active or passive cooling solutions provided from Kontron for the COMe-bBD6 are usually designed to cover the
power and thermal dissipation for a commercial grade temperature range used in a housing with proper air flow.
HOT Surface!
Do NOT touch! Allow to cool before servicing.
Documentation and CAD drawings of COMe-bBD6 heatspreader and cooling solutions are
provided at EMD Customer Section.
2.12 Onboard Fan Connector
Figure 7 displays an overhead view of the circuit board with the location of the fan connectors (shown in red). The fan
connectors are located underneath the circuit board.
www.kontron.com
// 39
COMe-bBD6 User Guide Rev. 1.4
Figure 7: Location of the FAN Connectors
Specification of the FAN Connector:

Part number (Molex) J8: 53261-0371, Mates with: 51021-0300, Crimp terminals: 50079-8100
Pin assignment:

Pin1: Tacho, Pin2: VCC, Pin3: GND
Table 22: Electrical Characteristics
Module Input Voltage
8.5 - 13V
>13V
FAN Output Voltage
8.5 - 13V
13V
Max. FAN Output Current
350mA
150mA
To connect a standard FAN with 3pin connector to the module please use adaptor cable KABHSP 200mm (96079-0000-00-0) or KAB-HSP 40mm (96079-0000-00-2).
Always check the FAN specifications according the output current limitation.
www.kontron.com
// 40
COMe-bBD6 User Guide Rev. 1.4
2.13 Onboard Test Connector
The onboard test connector is a 60-pin ITP60c processor debug port used for debugging the CPU complex and the
code that is running on it. To debug the board through the processor debug port, the compressed adapter
ITP60CADAPTER is required. For more information on the ITP60CADAPTER, refer to
http://designintools.intel.com/product_p/itp60cadapter.htm.
www.kontron.com
// 41
COMe-bBD6 User Guide Rev. 1.4
3/ Features and Interfaces
3.1
S5 Eco Mode
Kontron’s new high-efficient power-off state S5 Eco enables lowest power-consumption in soft-off state – less than 1
mA compared to the regular S5 state. This means a reduction by a factor of at least 200.
In the “normal” S5 mode the board is supplied by 5V_Stb and needs around 300mA just to stay off. This mode allows
to be switched on by power button, RTC event and WakeOnLan, even when it is not necessary. The new S5 Eco mode
reduces the current enormous.
The S5 Eco Mode can be enabled in BIOS Setup, when the BIOS supports this feature.
Following prerequisites and consequences occur when S5 Eco Mode is enabled

Wake using Power button only.

“Power On After Power Fail”/“State after G3”: only “stay off” is possible
3.2
Rapid Shutdown
3.2.1 Overview
Kontron has implemented a rapid shutdown function. It works as follows:
1.
An active-high shutdown signal is asserted by the COM Express Eval Type 6 carrier board through pin C67 of the
COM Express connector. The characteristics of the shutdown signal are as follows:

Amplitude 5.0V +/- 5%

Source impedance < = 50 ohms

Rise time ⇐ 1uS

Duration >= 20uS
The assertion of this signal causes all power regulators to be disabled and the internal power supply rails to be
discharged by crowbar circuits. The shutdown circuitry provides internal energy storage that maintains crowbar
activation for at least 2mS following the de-assertion of the shutdown signal. The circuit also incorporates a weak
input pulldown resistor so that the module will operate normally in systems where the rapid shutdown functionality is
not used and pin C67 of the COM Express is left unconnected.
2.
Simultaneously with the leading edge of shutdown, the 12V (main) input power to the module is removed and
these input power pins are externally clamped to ground though a crowbar circuit located on the COM Express
carrier board. This external clamping circuit must maintain a maximum resistance of approximately 1 ohm and be
activated for a minimum of 2mS.
3.
Simultaneously with the leading edge of shutdown, the 5V (standby) input power to the module is removed, if
present. External clamping on these pins is not necessary (but recommended) because it is clamped through the
module by the main 12V rail.
3.2.2 Crowbar implementation details
The crowbar circuits are designed to meet the following criteria on each rail. Upon assertion of the shutdown signal:

Voltage decay to 37% of initial value (equivalent to one RC time constant) within 400uS.

Voltage is below 1.5V within 2ms.
www.kontron.com
// 42
COMe-bBD6 User Guide Rev. 1.4
It is expected that the carrier's crowbar on the 12V and 5V rails are design based on similar criteria.
3.3
LPC
The Low Pin Count (LPC) Interface signals are connected to the LPC Bus bridge located in the CPU or chipset. The LPC
low speed interface can be used for peripheral circuits such as an external Super I/O Controller, which typically
combines legacy-device support into a single IC. The implementation of this subsystem complies with the COM
Express® Specification. Implementation information is provided in the COM Express® Design Guide maintained by
PICMG. Please refer to the official PICMG documentation for additional information.
The LPC bus does not support DMA (Direct Memory Access) and a zero delay clock buffer is required when more than
one device is used on LPC. This leads to limitations for ISA bus and SIO (standard I/O´s like Floppy or LPT interfaces)
implementations.
All Kontron COM Express® Computer-on-Modules imply BIOS support for following external baseboard LPC Super I/O
controller features for the Winbond/Nuvoton 3.3V 83627DHG-P:
Table 23: Supported BIOS Features
3.3V 83627DHG-P
AMI EFI APTIO V
PS/2
YES
COM1/COM2
YES
LPT
YES
HWM
NO
Floppy
NO
GPIO
NO
Features marked as not supported do not exclude OS support (e.g. HWM can be accessed by SMB). For any other LPC
Super I/O additional BIOS implementations are necessary. Please contact your local sales or support for further details.
3.4
Serial Peripheral Interface (SPI)
The Serial Peripheral Interface Bus or SPI bus is a synchronous serial data link standard named by Motorola. Devices
communicate in master/slave mode where the master device initiates the data frame. Multiple slave devices are
allowed with individual slave select (chip select) lines. Sometimes SPI is called a “four wire” serial bus, contrasting with
three, two, and one wire serial buses.
The SPI interface can only be used with a SPI flash device to boot from external BIOS on the
baseboard.
3.5
SPI boot
The COMe-bBD6 supports boot from an external SPI Flash. It can be configured by pin A34 (BIOS_DIS0#) and pin B88
(BIOS_DIS1#) in following configuration:
www.kontron.com
// 43
COMe-bBD6 User Guide Rev. 1.4
Table 24: SPI Boot Pin Configuration
Configuration
BIOS_DIS0#
BIOS_DIS1#
Function
1
open
open
Boot on module BIOS
2
GND
open
Boot on LPC firmware hub (FWH)
3
open
GND
Boot on carrier SPI
4
GND
GND
Boot on module SPI
By default, only the primary SPI Boot Device (chip select 0) is used in configuration 3 & 4. To
access the secondary SPI device (chip select 1), the BIOS must be customized.
Table 25: Supported SPI boot flash types for 8-SOIC package
Size
Manufacturer
Part Number
Device ID
128Mbit
Macronix
MX25L12805D
0xC22018
128Mbit
Micron
N25Q128
0x20BA18
128Mbit
Winbond
W25Q128FV
0xEF4018
3.5.1 Using an external SPI flash
The Kflash utility is available on version 0.06. The “v” verify parameter of this command is not implemented yet,
however a check on the size between the binary file and the spi flash is performed before the writing and/or saving
operation. First of all, you need to boot on the EFI Shell with an USB key containing the binary we want to flash the SPI
with, plugged on the system.
Depending on which SPI you would like to flash, you will need to use one jumper in particular (BIOS_DIS1) located on
the carrier Topanga Canyon Type 6 (J27).
To flash the carrier or module Flash chip:
1.
Connect a SPI flash with the correct size (similar to BIOS ROM file size) to the module SPI interface.
2.
Open pin A34 (BIOS_DIS0#) and B88 (BIOS_DIS1#) to boot from the module BIOS.
3.
Turn on the system and make sure your boot your USB is connected and boot on the EFI shell (you need to boot
with a BIOS binary that supports kflash utility in order to use it so version should be ≥ SPI_COMe_bBD6_0_06.bin).
4.
Connect pin B88 (BIOS_DIS1#) to ground to enable the external SPI flash.
5.
From the EFI shell, (see Figure 8) enter the name of the partition of your USB Key in this example; Hit FS0: then
enter.
www.kontron.com
// 44
COMe-bBD6 User Guide Rev. 1.4
Figure 8: Entering USB Key Partition Name
6.
If you want to see a help guide regarding “kflash” usage, enter kflash -h
Figure 9: Using kflash help option
7.
On your terminal, enter the following command:
kflash -p “binary_name.bin“
The following is displayed (see Figure 10):
www.kontron.com
// 45
COMe-bBD6 User Guide Rev. 1.4
Figure 10: Programming the Flash Image Drive
8.
When process is finished, power cycle the whole system.
Your system has now been updated.
For more information, visit the EMD Customer Section.
3.5.2 External SPI flash on Modules with Intel® ME
If booting from the external (baseboard mounted) SPI flash then exchanging the COM Express® module for another
one of the same type will cause the Intel® Management Engine to fail during next start. This is by design of the ME
because it bounds itself to the very module it has been flashed to. In the case of an external SPI flash this is the
module present at flash time.
To avoid this issue please make sure to conduct a complete flash of the external SPI flash device after changing the
COMexpress module for another one. If disconnecting and reconnecting the same module again this step is not
necessary.
3.6
M.A.R.S.
The Smart Battery implementation for Kontron Computer-on-Modules called Mobile Application for Rechargeable
Systems is a BIOS extension for external Smart Battery Manager or Charger. It includes support for SMBus
charger/selector (e.g. Linear Technology LTC1760 Dual Smart Battery System Manager) and provides ACPI
compatibility to report battery information to the Operating System.
www.kontron.com
// 46
COMe-bBD6 User Guide Rev. 1.4
Table 26: Reserved SM-Bus addresses for Smart Battery Solutions on the carrier
8-bit Address
7-bit Address
Device
12h
0x09
SMART_CHARGER
14h
0x0A
SMART_SELECTOR
16h
0x0B
SMART_BATTERY
3.7
UART
The COMe-bBD6 supports two Serial RX/TX only Ports defined in COM Express® specification on Pins A98/A99 for
UART0 and Pins A101/A102 for UART1. The implementation of the UART is compatible with 16C550 and is supported
by default by most operating systems. Resources are available to other UARTS such as from external LPC Super I/O.
UART features:

Hardware and software register compatible with all standard 16450 and 16550 UARTs

Implements all standard serial interface protocols
−
5, 6, 7 or 8 bits per character
−
Odd, Even or no parity detection and generation

1, 1.5 or 2 stop bit detection and generation

Internal baud rate generator and separate receiver clock input


−
Modem control functions
−
Prioritized transmit, receive, line status and
modem control interrupts
−
False start bit detection and recover
−
Line break detection and generation
−
Internal loop back diagnostic functionality
−
16 byte transmit and receive FIFOs
Implements only RX and TX signals.
−
RTS and DTR are not connected
−
CTS, DCD and DSR are tied to active
−
RI is tied to inactive
The UART clock is generated by the 33MHz LPC clock which results in an accuracy of 0.5% on all UART timings.
The First In First Out (FIFO) buffer memory within the UART between the receiver shift register and the host system
interface provides the host processor additional time to handle an interrupt from the UART and prevents loss of
received data at high rates.
www.kontron.com
// 47
COMe-bBD6 User Guide Rev. 1.4
3.8
Fast I2C
The COMe-bBD6 supports FPGA implemented LPC to I2C bridge. The I2C Interface supports clock from 127Hz to
400kHz (limited by on board devices and capacitive loading) and can be configured in Setup.
Specification for external I2C:

Speed up to 400kHz

Compatible to Philips I2C bus standard

Multi-Master capable

Clock stretching support and wait state generation

Interrupt or bit-polling driven byte-by-byte data-transfers

Arbitration lost interrupt with automatic transfer cancellation

Start/Stop signal generation/detection

Bus busy detection
3.9
GPIO - General Purpose Input and Output
The COMe-bBD6 offers four General Purpose Input (GPI) pins and four General Purpose Output (GPO) pins. On a 3.3V
level, digital inputs and outputs are available.
Table 27: GPIO Pins
Signal
Pin
Description
GPI0
A54
General Purpose Input 0
GPI1
A63
General Purpose Input 1
GPI2
A67
General Purpose Input 2
GPI3
A85
General Purpose Input 3
GPO0
A93
General Purpose Output 0
GPO1
B54
General Purpose Output 1
GPO2
B57
General Purpose Output 2
GPO3
B63
General Purpose Output 3
Figure 11: Configuring GPIO Pins using JIDA32/K-Station
The GPI and GPO pins can be configured using JIDA32/K-Station.
www.kontron.com
// 48
COMe-bBD6 User Guide Rev. 1.4
Please refer to the JIDA32/K-Station manual in the driver download packet on our EMD
Customer Section.
3.10 Triple Staged Watchdog Timer
3.10.1 Basics
A watchdog timer (or computer operating properly (COP) timer) is a computer hardware or software timer that
triggers a system reset or other corrective action if the main program, due to some fault condition, such as a hang,
neglects to regularly service the watchdog (writing a “service pulse” to it, also referred to as “kicking the dog”,
“petting the dog”, “feeding the watchdog” or “triggering the watchdog”). The intention is to bring the system back
from the nonresponsive state into normal operation.
The COMe-bBD6 offers a watchdog which works with three stages that can be programmed independently and used
one by one.
Table 28: Time-out events
0000b
No action
The stage is off and will be skipped.
0001b
Reset
A reset will restart the module and starts POST and operating system new.
0010b
NMI
A non-maskable interrupt (NMI) is a computer processor interrupt that cannot be ignored by standard
interrupt masking techniques in the system. It is typically used to signal attention for non-recoverable
hardware errors.
0011b
SMI
A system management interrupt (SMI) makes the processor entering the system management mode (SMM).
As such, specific BIOS code handles the interrupt. The current BIOS handler for the watchdog SMI currently
does nothing. For particular needs, contact Kontron customer support.
0100b
SCI
A system control interrupt (SCI) is a OS-visible interrupt to be handled by the OS using AML code
0101b
Delay -> No
action*
Might be necessary when an operating system must be started and the time for the first trigger pulse must
extended. (Only available in the first stage).
1000b
WDT Only
This setting triggers the WDT Pin on baseboard connector (COM Express® Pin B27) only.
1001b
Reset + WDT
1010b
NMI + WDT
1011b
SMI + WDT
1100b
SCI + WDT
1101b
DELAY + WDT > No action*
* After expiring the counter or triggering the stage action will be set to “No action”. The purpose is to allow a one-time
delay before starting the actual time. WDT signal (mode 1101b) asserted after stage timeout, not after stage
triggering.
3.10.2 WDT Signal
Pin B27 on COM Express® Connector offers a signal that can be asserted when a watchdog timer has not been
triggered within time. It can be configured to any of the three stages. Deassertion of the signal is done automatically
after reset. If deassertion during runtime is necessary, please ask your Kontron technical support for further help.
www.kontron.com
// 49
COMe-bBD6 User Guide Rev. 1.4
3.11 Intel® Fast Flash Standby™ / Rapid Start Technology™
The target of Intel® Fast Flash Standby™ (iFFS) (also known as Intel® Rapid Start Technology™ iRST) is to get a wake-up
time from S4. Normally, S4 is caused by the OS, which stores its information to the hard disk and then does a normal
shutdown. S4 resume takes quite long as the system does a normal BIOS POST and OS restores its information from
the hard disk.
IFFS does it in a different way. The Operating System initiates an S4 and stores its information in memory. After that,
the BIOS copies this OS information from DRAM to SSD and does a sleep state similar to S4 with nearly zero power. If
the system is resumed by the power button, the BIOS restores the memory content from the SSD to the DRAM and
does an S4 resume which is much faster.
3.11.1 Requirements

SATA Solid State Disk in AHCI mode

Free disk space on the SSD with at least the DRAM size

Operating System with disk partition tool to allocate the hibernation partition (e.g. Windows 7/8)

BIOS supporting iFFS feature
How to setup the Intel® Rapid Start Technology once the operating system is installed:
1.
Prepare a free disk space on your onboard or external SSD with at least the size of DRAM.
2.
Open cmd.exe in Administrator Mode and type diskpart.exe to open the Windows disk partition tool.
3.
DISKPART> list disk
4.
DISKPART> select disk X (X is disk number where you want to create the store partition. Refer to results from “list
disk” for exact disk number)
5.
DISKPART> create partition primary
6.
DISKPART> detail disk
7.
DISKPART> select Volume X (X is Volume of your store partition. Refer to results from “detail disk” for exact
volume number)
8.
DISKPART> set id=84 override (ID 84 marks the partition as hibernate partition)
9.
DISKPART> exit
Now there should be a Hibernate Partition visible in your disk management.
10. Reboot and enable iFFS in BIOS
www.kontron.com
// 50
COMe-bBD6 User Guide Rev. 1.4
Usage:
1.
Move system to Sleep/Standby (→S4).
2.
After configured period of time in Setup the system powers on automatically and information in DRAM moves to
non-volatile memory (default is 'immediately').
3.
System switches off again to iFFS (Power Supply can now be disconnected).
4.
When System is powered on, information moved back to DRAM (No display output during copy process).
5.
System resumes same as Sleep/Standby S4.
Depending on the platform iFFS enabled may disable the hibernate function in Windows
automatically.
Benefits:

Up to 6x battery life compared to Standby

Resume time reduced up to 75%
Measured resume times from Power-on to Win7 Log-on Screen on COMe-mCT10:

2.5” SATA II HDD 5400rpm: Hibernate: 22s, iFFs on onboard NANDrive: 17s

2.5” SATA III SSD: Hibernate: 18s, iFFS on SSD: 10s
3.12 Speedstep Technology
The Intel® processors offer the Intel® Enhanced SpeedStep™ technology that automatically switches between
maximum performance mode and battery-optimized mode, depending on the needs of the application being run. It
enables you to adapt high performance computing on your applications. When powered by a battery or running in idle
mode, the processor drops to lower frequencies (by changing the CPU ratios) and voltage, conserving battery life
while maintaining a high level of performance. The frequency is set back automatically to the high frequency, allowing
you to customize performance.
In order to use the Intel® Enhanced SpeedStep™ technology the operating system must support SpeedStep™
technology.
By deactivating the SpeedStep feature in the BIOS, manual control/modification of CPU performance is possible. Setup
the CPU Performance State in the BIOS Setup or use 3rd party software to control CPU Performance States.
3.13 C-States
New generation platforms include power saving features like SuperLFM, EIST (P-States) or C-States in O/S idle mode.
Activated C-States are able to dramatically decrease power consumption in idle mode by reducing the Core Voltage or
switching of parts of the CPU Core, the Core Clocks or the CPU Cache.
www.kontron.com
// 51
COMe-bBD6 User Guide Rev. 1.4
Table 29: Following C-States are defined
C-State
Description
Function
C0
Operating
CPU fully turned on
C1
Halt State
Stops CPU main internal clocks through software
C1E
Enhanced Halt
Similar to C1, additionally reduces CPU voltage
C2
Stop Grant
Stops CPU internal and external clocks through hardware
C2E
Extended Stop Grant
Similar to C2, additionally reduces CPU voltage
C3
Deep Sleep
Stops all CPU internal and external clocks
C3E
Extended Stop Grant
Similar to C3, additionally reduces CPU voltage
C4
Deeper Sleep
Reduces CPU voltage
C4E
Enhanced Deeper Sleep
Reduces CPU voltage even more and turns off the memory cache
C6
Deep Power Down
Reduces the CPU internal voltage to any value, including 0V
C7
Deep Power Down
Similar to C6, additionally LLC (LastLevelCache) is switched off
C-States are usually enabled by default for low power consumption, but active C-States my influence performance
sensitive applications or real-time systems.

Active C6-State may influence data transfer on external Serial Ports

Active C7-State may cause lower CPU and Graphics performance
It is recommended to disable C-States / Enhanced C-States in BIOS Setup if any problems occur.
3.14 Hyper Threading
Hyper Threading (officially termed Hyper Threading Technology or HTT) is an Intel®-proprietary technology used to
improve parallelization of computations performed on PC´s. Hyper-Threading works by duplicating certain sections of
the processor—those that store the architectural state but not duplicating the main execution resources. This allows a
Hyper- Threading equipped processor to pretend to be two “logical” processors to the host operating system, allowing
the operating system to schedule two threads or processes simultaneously. Hyper Threading Technology support
always relies on the Operating System.
3.15 ACPI Suspend Modes and Resume Events
The COMe-bBD6 supports the S-states S0, S4, S5. and S5ECO (see 3.1 S5 Eco Mode)
The following events resume the system from S4:

Power Button

WakeOnLan (2)
The following events resume the system from S5:

Power Button

WakeOnLan (2)
The following events resume the system from S5Eco:

Power Button
www.kontron.com
// 52
COMe-bBD6 User Guide Rev. 1.4
www.kontron.com
1.
OS must support wake up by USB devices and baseboard must power the USB Port with
StBy-Voltage.
2.
Depending on the Used Ethernet MAC/Phy WakeOnLan must be enabled in BIOS setup
and driver options.
// 53
COMe-bBD6 User Guide Rev. 1.4
4/ System Resources
4.1
Interrupt Request (IRQ) Lines
Table 30: List of Interrupt Requests
IRQ#
Used For
Available
Comment
0
Timer
No
-
1
Keyboard
No
-
2
Cascade
No
-
3
COM2
No
Onboard UART
4
COM1
No
Onboard UART
5
LPT
No
External SIO Winbond 83627DHG
6
-
Yes
-
7
-
Yes
-
8
RTC
No
-
9
ACPI
No
-
10
COM3 & COM4
No
External SIO Winbond 83627DHG
11
-
Yes
-
12
PS/2 Mouse
No
External SIO Winbond 83627DHG
13
FPU
No
-
14
-
Yes
-
15
-
Yes
-
4.2
Memory Area
The first 640 kB of DRAM are used as main memory. Using DOS, you can address 1 MB of memory directly. Memory
area above 1 MB (high memory, extended memory) is accessed under DOS by special drivers such as HIMEM.SYS and
EMM386.EXE, which are part of the operating system. Please refer to the operating system documentation or special
textbooks for information about HIMEM.SYS and EMM386.EXE. Other operating systems (Linux or Windows versions)
allow you to address the full memory area directly.
Table 31: Designated Memory Locations
Upper Memory
Used for
Available
Comment
C0000h-CFFFFh
Video ROM
No
-
E0000h-FFFFFh
System ROM
No
-
90000000h-FBFFBFFFh
PCIe Config Space
No
-
FBFFC000h-FBFFCFFFh
dmar0
No
-
FEC00000h-FEC003FFh
IOAPIC 0
No
-
FEC01000h-FEC013FFh
IOAPIC 1
No
-
FED00000h-FED003FFh
HPET 0
No
-
FF000000h-FFFFFFFFh
BIOS Flash
No
-
www.kontron.com
// 54
COMe-bBD6 User Guide Rev. 1.4
4.3
I/O Address Map
The I/O-port addresses of the bBD6 are functionally identical to a standard PC/AT. All addresses not mentioned in this
table should be available. We recommend that you do not use I/O addresses below 0100h with additional hardware
for compatibility reasons, even if available.
Table 32: Designated I/O Port Addresses
I/O Address
Used for
Available
Comment
0000-001F
DMA Controller
No
Fixed
0020-002D
Interrupt Controller
No
Fixed
0002E-002F
Onboard UART
No
Fixed
0030-003D
Interrupt Controller
No
Fixed
0040-0042
Timer/Counter
No
Fixed
004E-004F
Winbond 83627DHG
No
When SIO present on carrier
0050-0052
Timer/Counter
No
Fixed
0060-0064
Keyboard Controller
No
Fixed
0071-0077
RTC Controller
No
Fixed
0080
BIOS Post Code
No
Fixed
0081-0091
DMA Controller
No
Fixed
0092
Reset Generator
No
Fixed
0093-009F
DMA Controller
No
Fixed
00A0-00BD
Interrupt Controller
No
Fixed
00C0-00D1
DMA Controller
No
Fixed
00DE-00DF
DMA Controller
No
Fixed
00F0
FERR# / Interrupt Controller
No
Fixed
0240-0247
Winbond 83627DHG Serial Port 1
No
When SIO present on carrier
0248-024F
Winbond 83627DHG Serial Port 2
No
When SIO present on carrier
04D0-04D1
Interrupt Controller
No
Fixed
0A80-0AFF
FPGA
No
Fixed
0CF9
Reset Generator
No
Fixed
Other I/O addresses are dynamically allocated for PCI devices and not listed here. Refer to
your OS documentation on how to determine I/O addresses usage.
4.4
Peripheral Component Interconnect (PCI) Devices
All devices follow the Peripheral Component Interconnect 2.3 (PCI 2.3) respectively the PCI Express Base 1.0a
specification. The BIOS and OS control memory and I/O resources. Please see the PCI 2.3 specification for details.
www.kontron.com
// 55
COMe-bBD6 User Guide Rev. 1.4
Table 33: PCI Device list
PCI Device
B:D.F*
Interface
Comment
Host bridge: Intel Corporation Broadwell DMI2 (rev 02)
00:00.0
Internal
Chipset
PCI bridge: Intel Corporation Broadwell PCI Express Root Port 1 (rev 02)
00:01.0
Internal
Chipset
PCI bridge: Intel Corporation Broadwell PCI Express Root Port 1 (rev 02)
00:01.1
Internal
Chipset
PCI bridge: Intel Corporation Broadwell PCI Express Root Port 2 (rev 02)
00:02.0
Internal
Chipset
PCI bridge: Intel Corporation Broadwell PCI Express Root Port 2 (rev 02)
00:02.2
Internal
Chipset
PCI bridge: Intel Corporation Broadwell PCI Express Root Port 3 (rev 02)
00:03.0
Internal
Chipset
System peripheral: Intel Corporation Broadwell Adress Map/VTd_Misc/System Management (rev
02)
00:05.0
Internal
Chipset
System peripheral: Intel Corporation Broadwell IIO Hot Plug (rev 02)
00:05.1
Internal
Chipset
System peripheral: Intel Corporation Broadwell IIO RAS/Control Status/Global Errors (rev 02)
00:05.2
Internal
Chipset
PIC: Intel Corporation Broadwell I/O APIC (rev 02)
00:05.4
Internal
Chipset
Communication controller: Intel Corporation 8 Series/C220 Series Chipset Family MEI Controller
00:16.0
Internal
Chipset
Communication controller: Intel Corporation 8 Series/C220 Series Chipset Family MEI Controller
00:16.1
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #1
00:1c.0
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #2
00:1c.1
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #3
00:1c.2
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #4
00:1c.3
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #5
00:1c.4
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #6
00:1c.5
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #7
00:1c.6
Internal
Chipset
PCI bridge: Intel Corporation 8 Series/C220 Series Chipset Family PCI Express Root Port #8
00:1c.7
Internal
Chipset
USB controller: Intel Corporation 8 Series/C220 Series Chipset Family USB EHCI #1 (rev 05)
00:1d.0
Internal
Chipset
ISA bridge: Intel Corporation C224 Series Chipset Family Server Standard SKU LPC Controller
00:1f.0
Internal
Chipset
SATA controller: Intel Corporation 8 Series/C220 Series Chipset Family 6-port SATA Controller 1
00:1f.2
Internal
Chipset
SMBus: Intel Corporation 8 Series/C220 Series Chipset Family SMBus Controller (rev 05)
00:1f.3
Internal
Chipset
Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
01:00.0
Internal
On board LAN
Ethernet controller: Intel Corporation I210 Gigabit Network Connection (rev 03)
02:00.0
Internal
On board LAN
Xeon Processor D Family QuickData Technology Register DMA Channel 0
03:00.0
Internal
Chipset
Xeon Processor D Family QuickData Technology Register DMA Channel 1
03:00.1
Internal
Chipset
Xeon Processor D Family QuickData Technology Register DMA Channel 2
03:00.2
Internal
Chipset
Xeon Processor D Family QuickData Technology Register DMA Channel 3
03:00.3
Internal
Chipset
Ethernet controller: Intel Corporation Ethernet Connection X552 10 GbE Backplane
04:00.0
Internal
Chipset
Ethernet controller: Intel Corporation Ethernet Connection X552 10 GbE Backplane
04:00.1
Internal
Chipset
*
Bus:Device.Function
www.kontron.com
// 56
COMe-bBD6 User Guide Rev. 1.4
4.5
I2C Bus
Table 34: I2C Bus Port Addresses
I2C Address
Used For
Available
Comment
58h
S5 Eco
No
S5 Eco Resistor
A0h
JIDA-EEPROM
No
Module EEPROM
AEh
FRU-EEPROM
No
Recommended for Baseboard EEPROM
4.6
System Management (SM) Bus
The 8-bit SMBus addresses uses the LSB (Bit 0) for the direction. Bit0 = 0 defines the write address, Bit0 = 1 defines the
read address for the device. The 8-bit addresses listed below shows the write address for all devices. 7-bit SMBus
addresses shows the device address without Bit0.
Table 35: Designated I/O Port Addresses
8-bit
Address
7-bit
Address
Device
Comment
SMBus
58h
0x2C
HWM NCT7802Y (non ECC Design)
Do not use under any circumstances
SMB
A JIDA Bus No. like in former Modules cannot be provided because the EAPI driver
implementation enumerates the I2C busses dynamically. Please follow the initialization
process as provided in the EAPI specification.
www.kontron.com
// 57
COMe-bBD6 User Guide Rev. 1.4
5/ Pin-out List
The pins of the connectors are listed in the following tables:

Table 37: Connector X1A Row A Pin-out List

Table 38: Connector X1A Row B Pin-out List

Table 39: Connector X1B Row C Pin-out List

Table 40: Connector X1B Row D Pin-out List
These tables list the pins and signals according to the PICMG specification COM.0 Rev 2.1 Type 6 standard. The
descriptions of the pins found in these tables are brief. For a more detailed description of each pin, refer to the COM.0
Rev 2.1 Type 6 standard. The information provided under types, module terminations and comments are
complimentary information and for a list of terms used within these columns, refer to Table 36 and Table 134.
Row C and D have pins safely reused per pin COM.0 Rev 2.1 Type 6 standard characteristics to
provide additional Ethernet capabilities per 2.2.6. For more information, contact Kontron.
Table 36: Electrical characteristic
Type
Description
NC
Not connected (on this product)
I/O-3,3
Bi-directional 3,3 V IO-Signal
I/O-5T
Bi-dir. 3,3V I/O (5V Tolerance)
I/O-5
Bi-directional 5V I/O-Signal
I-3,3
3,3V Input
I/OD
Bi-directional Input/Output Open Drain
I-5T
3,3V Input (5V Tolerance)
OA
Output Analog
OD
Output Open Drain
O-1,8
1,8V Output
O-3,3
3,3V Output
O-5
5V Output
DP-I/O
Differential Pair Input/Output
DP-I
Differential Pair Input
DP-O
Differential Pair Output
PU
Pull-Up Resistor
PD
Pull-Down Resistor
PWR
Power Connection
www.kontron.com
// 58
COMe-bBD6 User Guide Rev. 1.4
To protect external power lines of peripheral devices, make sure that: the wires have the
right diameter to withstand the maximum available current the enclosure of the peripheral
device fulfills the fire-protection requirements of IEC/EN60950.
5.1
Connector X1A Row A
Table 37 lists the pin-outs for Connector X1A Row A.
Table 37: Connector X1A Row A Pin-out List
Pin
COME Signal
Description
Type
Termination
A1
GND_1
Power Ground
PWR
-
A2
GBE0_MDI3-
Gigabit Ethernet Media Dependent Interface
DP-I/O
-
A3
GBE0_MDI3+
A4
GBE0_LINK100#
100BT Ethernet controller speed indicator
OD-3.3
-
A5
GBE0_LINK1000#
1G BT Ethernet controller speed indicator
OD-3.3
-
A6
GBE0_MDI2-
Gigabit Ethernet Media Dependent Interface
DP-I/O
-
A7
GBE0_MDI2+
A8
GBE0_LINK#
Ethernet Controller Link Indicator
OD-3.3
-
A9
GBE0_MDI1-
Gigabit Ethernet Media Dependent Interface
DP-I/O
-
A10
GBE0_MDI1+
A11
GND_2
Power Ground
PWR
-
A12
GBE0_MDI0-
Gigabit Ethernet Media Dependent Interface
DP-I/O
-
A13
GBE0_MDI0+
A14
GBE0_CTREF
Reference voltage for Carrier Board Ethernet magnetics
center tap. The reference voltage is determined by the
requirements of the Module PHY and may be as low as
0V and as high as 3.3V.
PWR
-
A15
SUS_S3#
Indicates system is in Suspend to RAM state. An inverted
copy of SUS_S3# on the Carrier Board may be used to
enable the non-standby power on a typical ATX supply.
O-3.3
PD 244
A16
SATA0_TX+
Serial ATA or SAS transmit data
DP-O
-
A17
SATA0_TX-
A18
SUS_S4#
Indicates system is in Suspend to Disk state.
O-3.3
PD 10k
A19
SATA0_RX+
Serial ATA or SAS receive data
DP-I
-
A20
SATA0_RX-
A21
GND_3
Power Ground
PWR
-
A22
SATA2_TX+
Serial ATA or SAS transmit data
DP-O
-
A23
SATA2_TX-
A24
SUS_S5#
Indicates system is in Soft Off state.
O-3.3
-
A25
SATA2_RX+
Serial ATA or SAS receive data
DP-I
-
www.kontron.com
Comment
NC
Connected to SUS_S4#,
No S5# on BW-DE SOC
// 59
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
A26
SATA2_RX-
A27
BATLOW#
Indicates that external battery is low.
This port provides a battery-low signal to the Module.
I-3.3
PU 5.1k 3.3V
(S5)
A28
SATA_ACT#
PATA/SATA or SAS activity indicator
OD-3.3
PU 10k 3.3V (S0)
A29
AC/HDA_SYNC
Sample-synchronization signal to the CODEC(s).
O-3.3
-
GND
A30
AC/HDA_RST#
Reset output to CODEC.
O-3.3
-
GND
A31
GND_4
Power Ground
PWR
-
A32
AC/HDA_BITCLK
Serial data clock generated by the external CODEC(s).
I/O-3.3
-
NC
A33
AC/HDA_SDOUT
Serial TDM data output to the CODEC.
O-3.3
-
GND
A34
BIOS_DIS0#
Selection straps to determine the BIOS boot device.
The Carrier should only float these or pull them low,
please refer to COME.0 specification Table 4.13 for
strapping options of BIOS disable signals.
I-3.3
PU 6.6k to 16.5k
3.3V (S5)
Refer to chapter SPI boot
A35
THRMTRIP#
Indicates the CPU has entered thermal shutdown.
O-3.3
-
A36
USB6-
USB differential pairs (host)
DP-I/O
-
NC
A37
USB6+
A38
USB_6_7_OC#
USB over-current sense.
I-3.3
-
NC
A39
USB4-
USB differential pairs (host)
DP-I/O
-
NC
A40
USB4+
A41
GND_5
Power Ground
PWR
-
A42
USB2-
USB differential pairs (host)
DP-I/O
-
A43
USB2+
A44
USB_2_3_OC#
USB over-current sense. An open drain driver from a USB
current monitor on the Carrier Board may drive this line
low. Do not pull this line high on the Carrier Board.
I-3.3
PU 5.1k 3.3V
(S5)
A45
USB0-
USB differential pairs (host)
DP-I/O
-
A46
USB0+
A47
VCC_RTC
V_BAT
PWR
-
A48
EXCD0_PERST#
PCI ExpressCard expansion, reset
O-3.3
-
A49
EXCD0_CPPE#
PCI ExpressCard expansion, capable card request
I-3.3
PU 10k 3.3V (S0)
A50
LPC_SERIRQ
LPC Serial Interrupt
I/O-3.3
PU 10k 3.3V (S0)
A51
GND_6
Power Ground
PWR
-
A52
PCIE_TX5+
PCI Express Transmit
DP-O
-
A53
PCIE_TX5-
A54
GPI0
General purpose input pins.
I-3.3
PD 6.6k to 16.5k
3.3V (S5)
A55
PCIE_TX4+
PCI Express Transmit
DP-O
-
A56
PCIE_TX4-
A57
GND_7
Power Ground
PWR
-
A58
PCIE_TX3+
PCI Express Transmit
DP-O
-
A59
PCIE_TX3-
www.kontron.com
Comment
// 60
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
A60
GND_8
Power Ground
PWR
-
A61
PCIE_TX2+
PCI Express Transmit
DP-O
-
A62
PCIE_TX2-
A63
GPI1
General purpose input pins.
I-3.3
PD 6.6k to 16.5k
3.3V (S5)
A64
PCIE_TX1+
PCI Express Transmit
DP-O
-
A65
PCIE_TX1-
A66
GND_9
Power Ground
PWR
-
A67
GPI2
General purpose input pins.
I-3.3
PD 6.6k to 16.5k
3.3V (S5)
A68
PCIE_TX0+
PCI Express Transmit
DP-O
-
A69
PCIE_TX0-
A70
GND_10
Power Ground
PWR
-
A71
LVDS_A0+/eDP_TX2+
LVDS or DP transmit
DP-O
-
NC
A72
LVDS_A0-/eDP_TX2-
A73
LVDS_A1+/eDP_TX1+
LVDS or DP transmit
DP-O
-
NC
A74
LVDS_A1-/eDP_TX1-
A75
LVDS_A2+/eDP_TX0+
LVDS or DP transmit
DP-O
-
NC
A76
LVDS_A2-/eDP_TX0-
A77
LVDS/eDP_VDD_EN
LVDS or DP panel power enable
O-3.3
-
GND
A78
LVDS_A3+
LVDS transmit
DP-O
-
NC
A79
LVDS_A3-
A80
GND_11
Power Ground
PWR
-
A81
LVDS_A_CK+/eDP_TX
3+
LVDS clock or DP transmit
DP-O
-
NC
A82
LVDS_A_CK/eDP_TX3-
A83
LVDS_I2C_CK/eDP_A
UX+
I2C Clock for LVDS display use or eDP AUX differential
pair +
I/O-3.3
PU 2k21 3.3V
(S0)
Not used
A84
LVDS_I2C_DAT/eDP_
AUX-
I2C Data line for LVDS display use or eDP AUX differential
pair -
I/O-3.3
PU 2k21 3.3V
(S0)
Not used
A85
GPI3
General Purpose Input
I-3.3
PD 6.6k to 16.5k
3.3V (S5)
A86
RSVD1
NC
NC
-
A87
eDP_HPD
Detection of Hot Plug / Unplug and notification of the
link layer
I-3.3
-
A88
PCIE_CLK_REF+
DP-O
-
A89
PCIE_CLK_REF-
Reference clock output for all PCI Express and PCI
Express Graphics lanes.
A90
GND_12
Power Ground
PWR
-
www.kontron.com
Comment
NC
// 61
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
A91
SPI_POWER
Power supply for Carrier Board SPI – sourced from
Module – nominally 3.3V. The Module shall provide a
minimum of 100mA on SPI_POWER. Carriers shall use
less than 100mA of SPI_POWER. SPI_POWER shall only
be used to power SPI devices on the Carrier Board.
O-3.3
-
A92
SPI_MISO
Data in to Module from Carrier SPI
I-3.3
-
A93
GPO0
General Purpose Output
O-3.3
PD 6.6k to 16.5k
3.3V (S5)
A94
SPI_CLK
Clock from Module to Carrier SPI
O-3.3
-
A95
SPI_MOSI
Data out from Module to Carrier SPI
O-3.3
-
A96
TPM_PP
TPM Physical Presence
I-3.3
PD 10k
A97
TYPE10#/OLD_12V
Dual use pin. Indicates to the Carrier Board that a Type
10 Module is installed. Indicates to the Carrier that a Rev
1.0/2.0 Module is installed:
TYPE10#
NC
Pin-out R2.0
Strap
-
A98
SER0_TX/OLD_12V
serial port 0 TXD
O-3.3
-
A99
SER0_RX/OLD_12V
serial port 0 RXD
I-3.3
PU 3.3k 2.2V
(S0)
A100 GND_13
Power Ground
PWR
-
A101 SER1_TX/OLD_12V
serial port 1 TXD
O-3.3
-
A102 SER1_RX/OLD_12V
serial port 1 RXD
I-3.3
PU 3.3k 2.2V
(S0)
A103 LID#/OLD_12V
LID switch input
I-3.3
PU 5.1K 3.3V
(S5)
A104 VCC_12V_1
main input voltage (8.5-20V)
PWR 8.520V
-
A105 VCC_12V_2
main input voltage (8.5-20V)
PWR 8.520V
-
A106 VCC_12V_3
main input voltage (8.5-20V)
PWR 8.520V
-
A107 VCC_12V_4
main input voltage (8.5-20V)
PWR 8.520V
-
A108 VCC_12V_5
main input voltage (8.5-20V)
PWR 8.520V
-
A109 VCC_12V_6
main input voltage (8.5-20V)
PWR 8.520V
-
A110 GND_14
Power Ground
PWR
-
#
+ and -
Comment
NC for type 6 module
Active low
Differential pair differentiator
www.kontron.com
// 62
COMe-bBD6 User Guide Rev. 1.4
5.2
Connector X1A Row B
Table 38 lists the pin-outs for Connector X1A Row B.
Table 38: Connector X1A Row B Pin-out List
Pin
COME Signal
Description
Type
Termination
B1
GND_15
Power Ground
PWR
-
B2
GBE0_ACT#
Gigabit Ethernet Controller activity indicator
OD
-
B3
LPC_FRAME#
LPC frame indicates the start of an LPC cycle
O-3.3
-
B4
LPC_AD0
LPC multiplexed address, command and data bus
I/O-3.3
-
B5
LPC_AD1
B6
LPC_AD2
B7
LPC_AD3
B8
LPC_DRQ0#
LPC serial DMA request
I-3.3
PU 15k to 40k
3.3V (S0)
B9
LPC_DRQ1#
B10
LPC_CLK
LPC 33MHz clock output
O-3.3
-
B11
GND_16
Power Ground
PWR
-
B12
PWRBTN#
A falling edge creates a power button event. Power
button events can be used to bring a system out of S5
soft off and other suspend states, as well as powering
the system down.
I-3.3
PU 20k 3.3V
(S5eco)
PU 6.6k to 16.5k
3.3V (S5)
B13
SMB_CK
SMB bidirectional clock line.
I/OD-3.3
PU 2.2k 3.3V
(S5)
B14
SMB_DAT
SMB bidirectional data line.
I/OD-3.3
PU 2.2k 3.3V
(S5)
B15
SMB_ALERT#
SMB Alert can be used to generate an SMI# or to wake
the system.
I-3.3
PU 2.2k 3.3V
(S5)
B16
SATA1_TX+
Serial ATA or SAS transmit data
DP-O
-
B17
SATA1_TX-
B18
SUS_STAT#
Indicates imminent suspend operation; used to notify
LPC devices
O-3.3
-
B19
SATA1_RX+
Serial ATA or SAS receive data
DP-I
-
B20
SATA1_RX-
B21
GND_17
Power Ground
PWR
-
B22
SATA3_TX+
Serial ATA or SAS transmit data
DP-O
-
B23
SATA3_TX-
B24
PWR_OK
Power OK from main power supply. A high value
indicates that the power is good. This signal can be used
to hold off Module startup to allow Carrier based FPGAs
or other configurable devices time to be programmed.
I-3.3
PU 6.6k to 16.5k
3.3V (S5)
B25
SATA3_RX+
Serial ATA or SAS receive data.
DP-I
-
B26
SATA3_RX-
B27
WDT
A watchdog time-out event has occurred.
O-3.3
-
www.kontron.com
Comment
PU 15k to 40k
3.3V (S0)
// 63
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
Comment
B28
AC/HDA_SDIN2
Serial TDM data inputs from up to 3 CODECs.
I/O-3.3
-
NC
B29
AC/HDA_SDIN1
B30
AC/HDA_SDIN0
B31
GND_18
Power Ground
PWR
-
B32
SPKR
Output for audio enunciator - the "speaker" in PC-AT
systems. This port provides the PC beep signal and is
mostly intended for debugging purposes.
O-3.3
-
B33
I2C_CK
General purpose I2C port clock output.
I/O-3.3
PU 2k21 3.3V
(S5)
B34
I2C_DAT
General purpose I2C port data I/O line.
I/O-3.3
PU 2k21 3.3V
(S5)
B35
THRM#
Input from off-Module temp sensor indicating an overtemp situation.
I-3.3
PU 6.6k to 16.5k
3.3V (S5)
B36
USB7-
USB differential pairs (host and/or USB Client)
DP-I/O
-
NC
B37
USB7+
B38
USB_4_5_OC#
USB over-current sense.
I-3.3
-
NC
B39
USB5-
USB differential pairs (host)
DP-I/O
-
NC
B40
USB5+
B41
GND_19
Power Ground
PWR
-
B42
USB3-
USB differential pairs (host)
DP-I/O
-
B43
USB3+
B44
USB_0_1_OC#
USB over-current sense. An open drain driver from a USB I-3.3
current monitor on the Carrier Board may drive this line
low. Do not pull this line high on the Carrier Board.
PU 5.1k 3.3V
(S5)
B45
USB1-
USB differential pairs (host)
DP-I/O
-
B46
USB1+
B47
EXCD1_PERST#
PCI ExpressCard expansion, reset
O-3.3
-
B48
EXCD1_CPPE#
PCI ExpressCard expansion, capable card request
I-3.3
PU 10k 3.3V (S0)
B49
SYS_RESET#
Reset button input.
I-3.3
PU 6.6k to 16.5k
3.3V (S5)
B50
CB_RESET#
Reset output from Module to Carrier Board.
O-3.3
PU 10k 3.3V (S5)
B51
GND_20
Power Ground
PWR
-
B52
PCIE_RX5+
PCI Express receive lane. AC coupled off module.
DP-I
-
B53
PCIE_RX5-
B54
GPO1
General Purpose Output
O-3.3
PD 6.6k to 16.5k
3.3V (S5)
B55
PCIE_RX4+
PCI Express receive lane. AC coupled off module.
DP-I
-
B56
PCIE_RX4-
B57
GPO2
General Purpose Output
O-3.3
PD 6.6k to 16.5k
3.3V (S5)
B58
PCIE_RX3+
PCI Express receive lane. AC coupled off module.
DP-I
-
B59
PCIE_RX3-
www.kontron.com
// 64
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
B60
GND_21
Power Ground
PWR
-
B61
PCIE_RX2+
PCI Express receive lane. AC coupled off module.
DP-I
-
B62
PCIE_RX2-
B63
GPO3
General Purpose Output
O-3.3
PD 6.6k to 16.5k
3.3V (S5)
B64
PCIE_RX1+
PCI Express receive lane. AC coupled off module.
DP-I
-
B65
PCIE_RX1-
B66
WAKE0#
PCI Express wake up signal.
I-3.3
PU 1k 3.3V (S5)
B67
WAKE1#
General purpose wake up signal. May be used to
implement wake-up on PS2 keyboard or mouse activity.
I-3.3
PU 5.1k 3.3V
(S5)
B68
PCIE_RX0+
PCI Express receive lane. AC coupled off module.
DP-I
-
B69
PCIE_RX0-
B70
GND_22
Power Ground
PWR
-
B71
LVDS_B0+
LVDS Channel
DP-O
-
NC
B72
LVDS_B0-
B73
LVDS_B1+
LVDS Channel
DP-O
-
NC
B74
LVDS_B1-
B75
LVDS_B2+
LVDS Channel
DP-O
-
NC
B76
LVDS_B2-
B77
LVDS_B3+
LVDS Channel
DP-O
-
NC
B78
LVDS_B3-
B79
LVDS/eDP_BKLT_EN
LVDS or eDP panel backlight enable
DP-O
-
NC
B80
GND_23
Power Ground
PWR
-
GND
B81
LVDS_B_CK+
LVDS Channel
DP-O
-
NC
B82
LVDS_B_CK-
B83
LVDS/eDP_BKLT_CTRL LVDS or eDP panel backlight brightness control.
I/O-3.3
-
GND
B84
VCC_5V_SBY_1
5V Standby
PWR
-
B85
VCC_5V_SBY_2
B86
VCC_5V_SBY_3
B87
VCC_5V_SBY_4
B88
BIOS_DIS1#
Selection straps to determine the BIOS boot device.
The Carrier should only float these or pull them low,
please refer to COME.0 specification Table 4.13 for
strapping options of BIOS disable signals.
I-3.3
PU 6.6k to 16.5k
Refer to chapter SPI boot
B89
VGA_RED
Red for monitor. Analog DAC output, designed to drive a
37.5Ω equivalent load.
Analog
-
NC
B90
GND_24
Power Ground
PWR
-
B91
VGA_GRN
Green for monitor. Analog DAC output, designed to drive Analog
a 37.5Ω equivalent load.
-
NC
B92
VGA_BLU
Blue for monitor. Analog DAC output, designed to drive a Analog
37.5Ω equivalent load.
-
NC
www.kontron.com
Comment
// 65
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
Comment
B93
VGA_HSYNC
Horizontal sync output to VGA monitor
O-3.3
-
NC
B94
VGA_VSYNC
Vertical sync output to VGA monitor
O-3.3
-
NC
B95
VGA_I2C_CK
DDC clock line (I2C port dedicated to identify VGA
monitor capabilities).
OD-3.3
PU 2.21k 3.3V
(S0)
Not used
B96
VGA_I2C_DAT
DDC data line.
I-3.3
PU 2.21k 3.3V
(S0)
Not used
B97
SPI_CS#
Chip select for Carrier Board SPI.
NC
-
NC
B98
RSVD3
NC
NC
-
B99
RSVD4
NC
NC
-
B100
GND_25
Power Ground
PWR
-
B101
FAN_PWMOUT/OLD_
12V
Fan speed control by PWM Output.
OD
-
B102
FAN_TACHIN/OLD_12 Fan tachometer input for a fan with a two pulse output.
V
I-3.3
PU 47K 3.3V (S0)
B103
SLEEP#/OLD_12V
Sleep button signal used by the ACPI operating system to I-3.3
bring the system to sleep state or to wake it up again.
PU 5.1K 3.3V
(S5)
B104
VCC_12V_7
Main input voltage (8.5-20V)
-
B105
VCC_12V_8
PWR 8.520V
B106
VCC_12V_9
B107
VCC_12V_10
B108
VCC_12V_11
B109
VCC_12V_12
B110
GND_26
Power Ground
PWR
-
#
+ and -
Active low
Differential pair differentiator
www.kontron.com
// 66
COMe-bBD6 User Guide Rev. 1.4
5.3
Connector X1B Row C
Table 39 lists the pin-outs for Connector X1B Row C.
Table 39: Connector X1B Row C Pin-out List
Pin
COME Signal
Description
Type
Termination
C1
GND_27
Power Ground
PWR
-
C2
GND_28
C3
USB_SSRX0-
DP-I
-
C4
USB_SSRX0+
Additional receive signal for the SuperSpeed USB data
path. AC coupled off module.
C5
GND_29
Power Ground
PWR
-
C6
USB_SSRX1-
DP-I
-
C7
USB_SSRX1+
Additional receive signal for the SuperSpeed USB data
path. AC coupled off module.
C8
GND_30
Power Ground
PWR
-
C9
USB_SSRX2-
DP-I
-
C10
USB_SSRX2+
Additional receive signal for the SuperSpeed USB data
path. AC coupled off module.
C11
GND_31
Power Ground
PWR
-
C12
USB_SSRX3-
DP-I
-
C13
USB_SSRX3+
Additional receive signal for the SuperSpeed USB data
path. AC coupled off module.
C14
GND_32
Power Ground
PWR
-
C15
DDI1_PAIR6+
GBE1_CTREF / Reference voltage for Carrier Board
Ethernet magnetics center tap. The reference voltage
is determined by the requirements of the Module PHY
and may be as low as 0V and as high as 3.3V.
PWR
-
**
C16
DDI1_PAIR6-
GBE1_ACT# / Gigabit ethernet controller activity
indicator
OD-3.3
-
**
C17
RSVD1
NC
NC
-
C18
RSVD2
NC
NC
-
C19
PCIE_RX6+
PCI Express receive lane. AC coupled off module.
DP-I
-
C20
PCIE_RX6-
C21
GND_33
Power Ground
PWR
-
C22
PCIE_RX7+
PCI Express receive lane. AC coupled off module.
DP-I
-
C23
PCIE_RX7-
C24
DDI1_HPD
DDI Hotplug Detect
I-3.3
-
NC (3)
C25
DDI1_PAIR4+
DP-I/O
-
**
C26
DDI1_PAIR4-
GBE1_MDI1- / Gigabit Ethernet Media
Dependent Interface
GBE1_MDI1+
C27
RSVD3
NC
NC
-
C28
RSVD4
NC
NC
-
C29
DDI1_PAIR5+
GBE1_MDI0- / Gigabit Eth. Media Dependent Interface DP-I/O
C30
DDI1_PAIR5-
GBE1_MDI0+
www.kontron.com
-
Comment
**
// 67
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
C31
GND_34
Power Ground
PWR
-
C32
DDI2_CTRLCLK_AUX+
GBE1_LINK# / Ethernet Controller Link Indicator
OD-3.3
-
* (2)
C33
DDI2_CTRLDATA_AUX- GBE1_LINK100# / 100 BT Ethernet controller speed
indicator
OD-3.3
-
* (2)
C34
DDI2_DDC_AUX_SEL
GBE1_LINK1000# / 1G BT Ethernet controller speed
indicator
OD-3.3
-
* (1)
C35
RSVD5
NC
NC
-
C36
DDI3_CTRLCLK_AUX+
LAN_I2C_SCL / I2C Data line for LAN use
I/O-3.3
-
* (2)
C37
DDI3_CTRLDATA_AUX- LAN_I2C_SDA / I2C Clock for LAN use
I/O-3.3
-
* (2)
C38
DDI3_DDC_AUX_SEL
GND
I-3.3
-
(1)
C39
DDI3_PAIR0+
LAN0_KR_RX+ / 10G KR Ethernet Interface
DP-I
-
**
C40
DDI3_PAIR0-
LAN0_KR_RX-
C41
GND_35
Power Ground
PWR
-
C42
DDI3_PAIR1+
LAN_MDC0_LED0_1 / Management interface clock or
LED output
O-1.05
-
**
C43
DDI3_PAIR1-
LAN_MDIO0_LED0_0 / Management interface data or
LED output
I/O-1.05
-
**
C44
DDI3_HPD
DDI Hotplug Detect
I-3.3
-
NC (3)
C45
RSVD6
NC
NC
-
GND
C46
DDI3_PAIR2+
LAN1_KR_RX+ / 10G KR Ethernet Interface
DP-I
-
**
C47
DDI3_PAIR2-
LAN1_KR_RX-
C48
RSVD7
GND
NC
-
C49
DDI3_PAIR3+
LAN_MDC1_LED1_1 / Management interface clock or
LED output
O-1.05
-
**
C50
DDI3_PAIR3-
LAN_MDIO1_LED1_0 / Management interface data or
LED output
I/O-1.05
-
**
C51
GND_36
Power Ground
PWR
-
C52
PEG_RX0+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C53
PEG_RX0-
C54
TYPE0#
Indicate to the Carrier Board the Pin-out Type that is
implemented on the Module:
TYPE2#
TYPE1#
TYPE0#
GND
NC
NC
Type 6
Strap
-
C55
PEG_RX1+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C56
PEG_RX1-
C57
TYPE1#
refer to C54
Strap
-
C58
PEG_RX2+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C59
PEG_RX2-
C60
GND_37
Power Ground
PWR
-
C61
PEG_RX3+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C62
PEG_RX3-
www.kontron.com
Comment
NC for type 6 module
NC for type 6 module
// 68
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
C63
RSVD8
NC
NC
-
C64
RSVD9
NC
NC
-
C65
PEG_RX4+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C66
PEG_RX4-
C67
RSVD10
NC
NC
-
C68
PEG_RX5+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C69
PEG_RX5-
C70
GND_38
Power Ground
PWR
-
C71
PEG_RX6+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C72
PEG_RX6-
C73
GND_39
Power Ground
PWR
-
C74
PEG_RX7+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C75
PEG_RX7-
C76
GND_40
Power Ground
PWR
-
C77
RSVD11
NC
NC
-
C78
PEG_RX8+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C79
PEG_RX8-
C80
GND_41
Power Ground
PWR
-
C81
PEG_RX9+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C82
PEG_RX9-
C83
RSVD12
NC
NC
-
C84
GND_42
Power Ground
PWR
-
C85
PEG_RX10+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C86
PEG_RX10-
C87
GND_43
Power Ground
PWR
-
C88
PEG_RX11+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C89
PEG_RX11-
C90
GND_44
Power Ground
PWR
-
C91
PEG_RX12+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C92
PEG_RX12-
C93
GND_45
Power Ground
PWR
-
C94
PEG_RX13+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C95
PEG_RX13-
C96
GND_46
Power Ground
PWR
-
C97
RSVD13
NC
NC
-
C98
PEG_RX14+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C99
PEG_RX14-
www.kontron.com
Comment
refer to 3.2
// 69
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
C100
GND_47
Power Ground
PWR
-
C101
PEG_RX15+
PCI Express Graphics receive. AC coupled off Module.
DP-I
-
C102
PEG_RX15-
C103
GND_48
Power Ground
PWR
-
C104
VCC_12V_13
main input voltage (8.5-20V)
-
C105
VCC_12V_14
PWR 8.520V
C106
VCC_12V_15
C107
VCC_12V_16
C108
VCC_12V_17
C109
VCC_12V_18
C110
GND_49
Power Ground
PWR
-
#
+ and *
**
(1)
(2)
(3)
Comment
Active low
Differential pair differentiator
Module drives low or open drain. Module tolerates possible PU from type 6 carrier.
Safe, AC coupled on DDI carrier
100K PU to 3.3V or 1Meg PD on Topanga Canyon
2.2K PU to 3.3V on DDI carrier
Carrier includes a blocking FET to avoid backfeeding. However, Topanga drives push-pull on this, so not used.
www.kontron.com
// 70
COMe-bBD6 User Guide Rev. 1.4
5.4
Connector X1B Row D
Table 40 lists the pin-outs for Connector X1B Row D.
Table 40: Connector X1B Row D Pin-out List
Pin
COME Signal
Description
Type
Termination
D1
GND_50
Power Ground
PWR
-
D2
GND_51
D3
USB_SSTX0-
DP-O
-
D4
USB_SSTX0+
Additional transmit signal for the SuperSpeed USB data
path.
D5
GND_52
Power Ground
PWR
-
D6
USB_SSTX1-
DP-O
-
D7
USB_SSTX1+
Additional transmit signal for the SuperSpeed USB data
path.
D8
GND_53
Power Ground
PWR
-
D9
USB_SSTX2-
DP-O
-
D10
USB_SSTX2+
Additional transmit signal for the SuperSpeed USB data
path.
D11
GND_54
Power Ground
PWR
-
D12
USB_SSTX3-
DP-O
-
D13
USB_SSTX3+
Additional transmit signal for the SuperSpeed USB data
path.
D14
GND_55
Power Ground
PWR
-
D15
DDI1_CTRLCLK_AUX+
HDMI/DVI I2C CTRLCLK or DP AUX+ function.
I/O-3.3
-
NC (2)
D16
DDI1_CTRLDATA_AUX- HDMI/DVI I2C CTRLDATA or DP AUX- function
I/O-3.3
-
NC (2)
D17
RSVD14
NC
NC
-
D18
RSVD15
NC
NC
-
D19
PCIE_TX6+
PCI Express Transmit
DP-O
-
D20
PCIE_TX6-
D21
GND_56
Power Ground
PWR
-
D22
PCIE_TX7+
PCI Express Transmit
DP-O
-
D23
PCIE_TX7-
D24
RSVD16
NC
NC
-
D25
RSVD17
NC
NC
-
D26
DDI1_PAIR0+
GBE1_MDI3- / Gigabit Eth. Media Dependent Interface
DP-O
-
D27
DDI1_PAIR0-
GBE1_MDI3+
D28
RSVD18
NC
NC
-
D29
DDI1_PAIR1+
GBE1_MDI2- / Gigabit Eth. Media Dependent Interface
DP-O
-
D30
DDI1_PAIR1-
GBE1_MDI2+
D31
GND_57
Power Ground
PWR
-
D32
DDI1_PAIR2+
LAN_SPI_CLK / LAN firmware SPI flash clock
O-3.3
-
**
D33
DDI1_PAIR2-
LAN_SPI_CS# / LAN firmware SPI flash chip select
O-3.3
-
**
D34
DDI1_DDC_AUX_SEL
LAN_SPI_HOLD / LAN firmware SPI flash hold
I-3.3
-
* (1)
www.kontron.com
Comment
**
**
// 71
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
D35
RSVD19
LAN_DETECT# / When grounded indicates the carrier
implements the custom pinout for GBE2 and 10G LAN
I-3.3
-
D36
DDI1_PAIR3+
LAN_SPI_MISO / LAN firmware SPI data output
I-3.3
-
**
D37
DDI1_PAIR3-
LAN_SPI_MOSI / LAN firmware SPI data input
O-3.3
-
**
D38
RSVD20
GND
NC
-
D39
DDI2_PAIR0+
LAN0_KR_TX+ / 10G KR Ethernet Interface
DP-O
-
D40
DDI2_PAIR0-
LAN0_KR_TX
D41
GND_58
Power Ground
PWR
-
D42
DDI2_PAIR1+
LAN_SDP0_0 / Software defined pin
OD-3.3
-
**
D43
DDI2_PAIR1-
LAN_SDP0_1 / Software defined pin
I-3.3
-
**
D44
DDI2_HPD
DDI Hotplug Detect
I-3.3
-
NC (3)
D45
RSVD21
NC
NC
-
GND
D46
DDI2_PAIR2+
LAN1_KR_TX+ / 10G KR Ethernet Interface
DP-O
-
**
D47
DDI2_PAIR2-
LAN1_KR_TX-
D48
RSVD22
NC
NC
-
GND
D49
DDI2_PAIR3+
LAN_SDP1_0 / Software defined pin
OD-3.3
-
**
D50
DDI2_PAIR3-
LAN_SDP1_1 / Software defined pin
I-3.3
-
**
D51
GND_59
Power Ground
PWR
-
D52
PEG_TX0+
PCI Express Graphics transmit.
DP-O
-
D53
PEG_TX0-
D54
PEG_LANE_RV#
PCIexpress Graphics Lane Reversal
I-3.3
PU 10k 3.3V (S0)
D55
PEG_TX1+
PCI Express Graphics transmit.
DP-O
-
D56
PEG_TX1-
D57
TYPE2#
refer to C54
Strap
-
D58
PEG_TX2+
PCI Express Graphics transmit.
DP-O
-
D59
PEG_TX2-
D60
GND_60
Power Ground
PWR
-
D61
PEG_TX3+
PCI Express Graphics transmit.
DP-O
-
D62
PEG_TX3-
D63
RSVD23
NC
NC
-
D64
RSVD24
NC
NC
-
D65
PEG_TX4+
PCI Express Graphics transmit.
DP-O
-
D66
PEG_TX4-
D67
GND_61
Power Ground
PWR
-
D68
PEG_TX5+
PCI Express Graphics transmit.
DP-O
-
D69
PEG_TX5-
D70
GND_62
Power Ground
PWR
-
www.kontron.com
Comment
**
GND for type 6 module
// 72
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
Description
Type
Termination
D71
PEG_TX6+
PCI Express Graphics transmit.
DP-O
-
D72
PEG_TX6-
D73
GND_63
Power Ground
PWR
-
D74
PEG_TX7+
PCI Express Graphics transmit.
DP-O
-
D75
PEG_TX7-
D76
GND_64
Power Ground
PWR
-
D77
RSVD25
NC
NC
-
D78
PEG_TX8+
PCI Express Graphics transmit.
DP-O
-
D79
PEG_TX8-
D80
GND_65
Power Ground
PWR
-
D81
PEG_TX9+
PCIexpress Graphics Transmit + (9)
DP-O
-
D82
PEG_TX9-
D83
RSVD26
NC
NC
-
D84
GND_66
Power Ground
PWR
-
D85
PEG_TX10+
PCI Express Graphics transmit.
DP-O
-
D86
PEG_TX10-
D87
GND_67
Power Ground
PWR
-
D88
PEG_TX11+
PCI Express Graphics transmit.
DP-O
-
D89
PEG_TX11-
D90
GND_68
Power Ground
PWR
-
D91
PEG_TX12+
PCI Express Graphics transmit.
DP-O
-
D92
PEG_TX12-
D93
GND_69
Power Ground
PWR
-
D94
PEG_TX13+
PCI Express Graphics transmit.
DP-O
-
D95
PEG_TX13-
D96
GND_70
Power Ground
PWR
-
D97
RSVD27
NC
NC
-
D98
PEG_TX14+
PCI Express Graphics transmit.
DP-O
-
D99
PEG_TX14-
D100 GND_71
Power Ground
PWR
-
D101 PEG_TX15+
PCI Express Graphics transmit.
DP-O
-
D103 GND_72
Power Ground
PWR
-
D104 VCC_12V_19
main input voltage (8.5-20V)
PWR 8.520V
-
Comment
D102 PEG_TX15-
D105 VCC_12V_20
D106 VCC_12V_21
D107 VCC_12V_22
www.kontron.com
// 73
COMe-bBD6 User Guide Rev. 1.4
Pin
COME Signal
D108 VCC_12V_23
Description
Type
Termination
main input voltage (8.5-20V)
PWR 8.520V
-
Power Ground
PWR
-
D109 VCC_12V_24
D110 GND_73
#
+ and *
**
(1)
(2)
(3)
Comment
Active low
Differential pair differentiator
Module drives low or open drain. Module tolerates possible PU from type 6 carrier.
Safe, AC coupled on DDI carrier
100K PU to 3.3V or 1Meg PD on Topanga Canyon
2.2K PU to 3.3V on DDI carrier
Carrier includes a blocking FET to avoid backfeeding. However, Topanga drives push-pull on this, so not used.
www.kontron.com
// 74
COMe-bBD6 User Guide Rev. 1.4
6/ BIOS Operation
The module is equipped with AMI® Aptio V, which is located in an onboard SPI serial flash memory.
The BIOS version covered in this document might not be the latest version. The latest version
might have certain differences to the BIOS options and features described in this chapter.
6.1
Determining the BIOS Version
The AMI® Aptio version is displayed in the main menu of the setup utility.

BIOS Vendor: American Megatrends

Core Version: x.x.x.x

Project Version: COMe_bBD6_Rx.xx x64

Build Date and Time: mm/dd/yyyy hh:mm:ss
6.2
BIOS Update
Kontron provides continuous BIOS updates for Computer-on-Modules. The updates are provided for download on
http://emdcustomersection.kontron.com with a detailed change description within the according Product Change
Notification (PCN).
Please register for the EMD Customer Section to get access to BIOS downloads and PCN
service.
Therefore, it is strongly recommended to use the “Kflash” shell utility available from version 0.06 with the BIOS binary
update to flash the whole SPI region (16MB).
1.
Boot the module to EFI Shell with access to the BIOS image.
2.
Execute “kflash “ shell utility as described in 3.5.1.
Backup the BIOS / Create a BIOS with custom defaults:
1.
Change your BIOS settings according to your needs and backup your customized binary onto a USB storage
device.
2.
Save and Exit Setup to EFI Shell.
3.
On your terminal, make sure to navigate to the USB key.
4.
Enter the following command to read SPI and save content to file “binary_name.bin“ in USB storage:
kflash -s binary_name.bin
Now you can clone the BIOS with your customized default settings to other modules or external SPI flashes with the
above “kflash“ Shell utility and the new customized and saved binary (“binary_name.bin“).
www.kontron.com
// 75
COMe-bBD6 User Guide Rev. 1.4
Any modification of the update process may damage your module.
AMI APTIO update utilities for DOS, EFI Shell and Windows are available for free at AMI.com:
http://www.ami.com/support/downloads/amiflash.zip.
6.3
Setup Guide
The Aptio Setup Utility changes system behavior by modifying the Firmware configuration. The setup program uses a
number of menus to make changes and turn features on or off.
Functional keystrokes in POST:
Table 41: Key Assignment
Key
Function
DEL
Enter Setup
F2
Enter Setup
F7
Boot Menu
6.4
POST Codes
Table 42: Important POST codes during boot-up
Key
Function
AB
BIOS Setup
AD
EFI Shell
AE
Windows
6.4.1 Start AMI® Aptio Setup Utility
To start the AMI® BIOS setup utility, press <DEL> or <F2> when the following string appears during bootup:
Press <DEL> to enter Setup
The setup utility screen appears.
The Setup Screen is composed of several sections:
Table 43: BIOS Setup Screen Sections
Setup Screen
Location
Function
Menu Bar
Top
Lists and selects all top level menus.
Legend Bar
Right side Bottom
Lists setup navigation keys.
Item Specific Help Window
Right side Top
Help for selected item.
Menu Window
Left Center
Selection fields for current menu.
6.4.1.1 Menu Bar
www.kontron.com
// 76
COMe-bBD6 User Guide Rev. 1.4
The menu bar at the top of the window lists different menus. Use the left/right arrow keys to make a selection.
6.4.1.2 Legend Bar
Use the keys listed in the legend bar on the bottom to make your selections or exit the current menu. The table below
describes the legend keys and their alternates.
Table 44: Legend Keys List
Key
Function
← or → Arrow key
Select a menu.
↑ or ↓ Arrow key
Select fields in current menu.
<Home> or <End>
Move cursor to top or bottom of current window.
<PgUp> or <PgDn>
Move cursor to next or previous page.
+/-
Change Option
<Enter>
Execute command or select submenu.
<F1>
General Help window.
<F2>
Previous Values
<F3>
Load the optimized default configuration.
<F4>
Save and exit.
<Esc>
Exit menu.
6.4.1.3 Selecting an Item
Use the ↑ or ↓ key to move the cursor to the field you want. Then use the + and – keys to select a value for that field.
The Save Value commands in the Exit menu save the values displayed in all the menus.
6.4.1.4 Displaying Submenus
Use the ← or → key to move the cursor to the submenu you want. Then press <Enter>. A pointer
submenus.
marks all
6.4.1.5 Item Specific Help Window
The Help window on the right side of each menu displays the Help text for the selected item. It updates as you move
the cursor to each field.
6.4.1.6 General Help Window
Pressing <F1> on a menu brings up the General Help window that describes the legend keys and their alternates. Press
<Esc> to exit the General Help window.
www.kontron.com
// 77
COMe-bBD6 User Guide Rev. 1.4
6.5
BIOS Setup
6.5.1 Main
Figure 12: Main Menu Screen
Table 45: Main Features List
Feature
Options
Description
System Language
English
Choose the system default language.
System Date
[mm/dd/yyyy]
Set the Date. Use Tab to switch between Date elements.
System Time
[hh:mm:ss]
Set the Time. Use Tab to switch between Time elements.
www.kontron.com
// 78
COMe-bBD6 User Guide Rev. 1.4
6.5.1.1 Platform Information
Figure 13: Platform Information Menu Screen
www.kontron.com
// 79
COMe-bBD6 User Guide Rev. 1.4
6.5.2 Advanced
Figure 14: Advanced Menu Screen
www.kontron.com
// 80
COMe-bBD6 User Guide Rev. 1.4
6.5.2.1 iSCSI Configuration
Figure 15: iSCSI Configuration Menu Screen
www.kontron.com
// 81
COMe-bBD6 User Guide Rev. 1.4
6.5.2.2 Trusted Computing
Figure 16: Trusted Computing Menu Screen
Table 46: Trusted Computing Features List
Feature
Options
Description
Security Device Support
Disable
Enable
Enables or Disables BIOS support for security device. O.S. will not show Security Device. TCG EFI
protocol and INT1A interface will not be available.
TPM State
Disabled
Enabled
Enable/Disable Security Device. NOTE: Your Computer will reboot during restart in order to change
State of the Device.
Pending operation
None
TPM Clear
Schedule an Operation for the Security Device. NOTE: Your Computer will reboot during restart in
order to change State of the Device.
Platform Hierarchy
Disabled
Enabled
Enable or Disable Platform Hierarchy
Storage Hierarchy
Disabled
Enabled
Enable or Disable Storage Hierarchy
Endorsement Hierarchy
Disabled
Enabled
Enable or Disable Endorsement Hierarchy
HashPolicy
Sha-1
Sha-2
Select the Hash policy to use. SHA-2 is most secure but might not be supported by all Operating
Systems
Device Select
TPM 1.2
TPM 2.0
Auto
TPM 1.2 will restrict support to TPM 1.2 devices, TPM 2.0 will restrict support to TPM 2.0 devices,
Auto will support both with the default set to TPM 2.0 devices if not found, TPM 1.2 devices will be
enumerated
www.kontron.com
// 82
COMe-bBD6 User Guide Rev. 1.4
6.5.2.3 ACPI Settings
Figure 17: ACPI Settings Menu Screen
Table 47: ACPI Settings Features List
Feature
Options
Description
Enable ACPI Auto Configuration
Disabled
Enabled
Enables or Disables BIOS ACPI Auto Configuration.
Enable Hibernation
Disabled
Enabled
Enables or Disables System ability to Hibernate (OS/S4 Sleep State). This
option may be not effective with some OS.
Lock Legacy Resources
Disabled
Enabled
Enables or Disables Lock of Legacy Resources
www.kontron.com
// 83
COMe-bBD6 User Guide Rev. 1.4
6.5.2.4 Miscellaneous
Figure 18: Miscellaneous Menu Screen
Table 48: Miscellaneous Features List
Feature
Options
Description
I2C Speed
200
Select I2C Bus Speed in kHz, min. 1kHz, max. 400kHz. For a default system 200kHz should be an
appropriate value.
Reset Button Behavior
Chipset Reset
Power Cycle
Select Reset Button Behavior: Chipset Reset, Power Cycle
S5 Eco
Disabled
Enabled
Reduce supply current in Soft Off (S5) to less than 1mA. If enabled, power button is the only wakeup
source in S5! See manual for restrictions in S5 Eco.
Sleep Button
Disabled
Enabled
Shows or hides Sleep Button inside ACPI OS
TPM Enable
Disabled
Enabled
Enable/Disable TPM (Trusted Platform Module)
PCI ExpressCard 0
Port 1
…
Port 8
Disabled
Controls PCIe Port for ExpressCard support.
PCI ExpressCard 1
Port 1
…
Port 8
Disabled
Controls PCIe Port for ExpressCard support.
www.kontron.com
// 84
COMe-bBD6 User Guide Rev. 1.4
6.5.2.5 Generic LPC Decode Ranges
Figure 19: Generic LPC Decode Ranges Menu Screen
Table 49: Generic LPC Decode Ranges Features List
Feature
Options
Description
Generic LPC
Decode 1
Disabled
Enabled
Enable generic LPC decode range.
www.kontron.com
// 85
COMe-bBD6 User Guide Rev. 1.4
6.5.2.6 Smart Battery Configuration
Figure 20: Smart Battery Configuration Menu Screen
Table 50: Smart Battery Configuration Features List
Feature
Options
Description
M.A.R.S.
Disabled
Auto
Charger
Manager
Preset M.A.R.S. Smart Battery System mode. System must be restarted to reflect mode changes.
www.kontron.com
// 86
COMe-bBD6 User Guide Rev. 1.4
6.5.2.7 Battery Information
Figure 21: Battery Information Menu Screen
www.kontron.com
// 87
COMe-bBD6 User Guide Rev. 1.4
6.5.2.8 Watchdog
Figure 22: Watchdog Menu Screen
Table 51: Watchdog Features List
Feature
Options
Description
Auto-reload
Disabled
Enabled
Enable automatic reload of watchdog timers on timeout.
Global Lock
Disabled
Enabled
If set to enabled, all Watchdog registers (except WD_KICK) become read only until the board is
reset.
Stage 1 Mode
Disabled
Reset
NMI
SMI
SCI
Delay
WDT Signal only
Select Action for this Watchdog stage
www.kontron.com
// 88
COMe-bBD6 User Guide Rev. 1.4
6.5.2.9 FPD UART Super IO Configuration
This setup option is available if a LPC SuperI/O Nuvoton 83627 is present on the baseboard. By default the COMebBD6 supports the legacy interfaces of 3.3V 83627DHG-P on external LPC. The SIO hardware monitor is not supported
in the setup.
Figure 23: FPD UART Super IO Configuration Menu Screen
www.kontron.com
// 89
COMe-bBD6 User Guide Rev. 1.4
6.5.2.10 FPD UART Serial Port 1 Configuration
Figure 24: FPD UART Serial Port 1 Configuration Menu Screen
Table 52: FPD UART Serial Port 1 Configuration Features List
Feature
Options
Description
Serial Port
Disabled
Enabled
Enable or Disable Serial Port (COM)
Change Settings
AUTO
IO=3F8h; IRQ=4;
IO=3F8h, IRQ=3,4,5,6,7,9,10,11,12;
IO=2F8h, IRQ=3,4,5,6,7,9,10,11,12;
IO=3E8h, IRQ=3,4,5,6,7,9,10,11,12;
IO=2E8h, IRQ=3,4,5,6,7,9,10,11,12;
Select an optimal setting for Super IO Device
www.kontron.com
// 90
COMe-bBD6 User Guide Rev. 1.4
6.5.2.11 FPD UART Serial Port 2 Configuration
Figure 25: FPD UART Serial Port 2 Configuration Menu Screen
Table 53: FPD UART Serial Port 2 Configuration Features List
Feature
Options
Description
Serial Port
Disabled
Enabled
Enable or Disable Serial Port (COM)
Change Settings
AUTO
IO=2F8h; IRQ=3;
IO=3F8h, IRQ=3,4,5,6,7,9,10,11,12;
IO=2F8h, IRQ=3,4,5,6,7,9,10,11,12;
IO=3E8h, IRQ=3,4,5,6,7,9,10,11,12;
IO=2E8h, IRQ=3,4,5,6,7,9,10,11,12;
Select an optimal setting for Super IO Device
www.kontron.com
// 91
COMe-bBD6 User Guide Rev. 1.4
6.5.2.12 W83627DHGSEC Super IO Configuration
Figure 26: W83627DHGSEC Super IO Configuration Menu Screen
www.kontron.com
// 92
COMe-bBD6 User Guide Rev. 1.4
6.5.2.13 W83627DHGSEC Serial Port 1 Configuration
Figure 27: W83627DHGSEC Serial Port 1 Configuration Menu Screen
Table 54: W83627DHGSEC Serial Port 1 Configuration Features List
Feature
Options
Description
Serial Port
Disabled
Enabled
Enable or Disable Serial Port (COM)
Change Settings
Auto
IO=240h; IRQ=10;
IO=240h, IRQ=3,4,5,6,7,10,11,12;
IO=248h, IRQ=3,4,5,6,7,10,11,12;
IO=250h, IRQ=3,4,5,6,7,10,11,12;
IO=258h, IRQ=3,4,5,6,7,10,11,12;
IO=260h, IRQ=3,4,5,6,7,10,11,12;
IO=268h, IRQ=3,4,5,6,7,10,11,12;
Select an optimal settings for Super IO Device
www.kontron.com
// 93
COMe-bBD6 User Guide Rev. 1.4
6.5.2.14 W83627DHGSEC Serial Port 2 Configuration
Figure 28: W83627DHGSEC Serial Port 2 Configuration Menu Screen
Table 55: W83627DHGSEC Serial Port 2 Configuration Features List
Feature
Options
Description
Serial Port
Disabled
Enabled
Enable or Disable Serial Port (COM)
Change Settings
Auto
IO=248h; IRQ=10;
IO=240h, IRQ=3,4,5,6,7,10,11,12;
IO=248h, IRQ=3,4,5,6,7,10,11,12;
IO=250h, IRQ=3,4,5,6,7,10,11,12;
IO=258h, IRQ=3,4,5,6,7,10,11,12;
IO=260h, IRQ=3,4,5,6,7,10,11,12;
IO=268h, IRQ=3,4,5,6,7,10,11,12;
Select an optimal setting for Super IO Device
Device Mode
Standard Serial Port Mode
IrDA Active pulse 1.6 uS
IrDA Active pulse 3/16 bit time
ASKIR Mode
Change the Serial Port mode.
www.kontron.com
// 94
COMe-bBD6 User Guide Rev. 1.4
6.5.2.15 W83627DHGSEC Parallel Port Configuration
Figure 29: W83627DHGSEC Parallel Port Configuration Menu Screen
Table 56: W83627DHGSEC Parallel Port Configuration Features List
Feature
Options
Description
Parallel Port
Disabled
Enabled
Enable or Disable Parallel Port (LPT/LPTE)
Change Settings
AUTO
IO=378h; IRQ=5;
IO=378h, IRQ=5,6,7,9,10,11,12;
IO=278h, IRQ=5,6,7,9,10,11,12;
IO=3BCh, IRQ=5,6,7,9,10,11,12;
Select an optimal settings for Super IO Device.
Device Mode
STD Printer Mode
SPP Mode
EPP-1.9 and SPP Mode
EPP-1.7 and SPP Mode
ECP Mode
ECP Mode & EPP 1.9 Mode
ECP Mode & EPP 1.7 Mode
Change the Printer Port mode.
www.kontron.com
// 95
COMe-bBD6 User Guide Rev. 1.4
6.5.2.16 H/W Monitor
Hardware Monitor measurements and configuration for the onboard Nuvoton NCT7802Y.
Figure 30: H/W Monitor Menu Screen
Table 57: H/W Monitor Features List
Feature
Options
Description
CPU Temperature
xx°C
Shows the measured temperature of the CPU Diode with onboard HWM.
PCH Temperature
xx°C
Shows the internal Platform Controller Hub temperature.
Module Temperature
xx°C
Shows the internal hardware monitor temperature.
CPU FAN
xxxx rpm
Shows the fan speed of onboard FAN connector.
FAN Control
Disabled
Manual
Auto
Set fan control mode. 'Disable' will totally stop the fan.
Fan Pulse
2
Number of pulses the fan produces during one revolution. Range 1-4
Fan Trip Point
50
Temperature where fan accelerates. Range: 20 – 80 C.
Trip Point Speed
50
Fan speed at trip point in %. Minimum value is 30. Fan always runs at 100% at TJmax – 10
C.
Reference Temperature
PCH Temperature
Module Temperature
Determines the temperature source which is used for automatic fan control
www.kontron.com
// 96
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
CPU Temperature
External FAN
xxxx rpm
Shows the fan speed of external COMe FAN.
FAN Control
Disabled
Manual
Auto
Set fan control mode. 'Disable' will totally stop the fan.
Fan Pulse
2
Number of pulses the fan produces during one revolution. Range 1-4
Fan Trip Point
50
Temperature where fan accelerates. Range 20 – 80 C
Trip Point Speed
50
Fan speed at trip point in %. Minimum value is 30. Fan always runs at 100% at TJmax – 10
C.
Reference Temperature
PCH Temperature
Module Temperature
CPU Temperature
Determines the temperature source which is used for automatic fan control.
5.0V Standby
x.xx V
Shows the 5V Standby Voltage input.
Batt volt at COMe pin
x.xx V
Shows the RTC Battery Voltage input measured at COMe connector.
Widerange Vcc
x.xx V
Shows the Module Main Input Voltage.
www.kontron.com
// 97
COMe-bBD6 User Guide Rev. 1.4
6.5.2.17 Serial Port Console Redirection
Figure 31: Serial Port Console Redirection Menu Screen
Table 58: Serial Port Console Redirection Features List
Feature
Options
Description
COM1
Console Redirection
Disabled
Enabled
Console Redirection Enable or Disable.
COM2
Console Redirection
Disabled
Enabled
Console Redirection Enable or Disable.
COM3
Console Redirection
Disabled
Enabled
Console Redirection Enable or Disable.
COM4
Console Redirection
Disabled
Enabled
Console Redirection Enable or Disable.
Serial Port for Out-of-Band
Management/Windows Emergency
Management Services (EMS)
Console Redirection
Disabled
Enabled
Console Redirection Enable or Disable.
www.kontron.com
// 98
COMe-bBD6 User Guide Rev. 1.4
6.5.2.18 Console Redirection Settings
Figure 32: Console Redirection Settings Menu Screen
Table 59: Console Redirection Settings Features List
Feature
Options
Description
Terminal Type
VT100
VT100+
VT-UTF8
ANSI
Emulation: ANSI: Extended ASCII char set. VT100: ASCII char set. VT100+: Extends VT100 to support
color, function keys, etc. VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.
Bits per second
9600
19200
38400
57600
115200
Selects serial port transmission speed. The speed must be matched on the other side. Long or noisy
lines may require lower speeds.
Data Bits
7
8
Data Bits
Parity
None
Even
Odd
Mark
Space
A parity bit can be sent with the data bits to detect some transmission errors. Even: parity bit is 0 if the
num of 1's in the data bits is even. Odd: parity bit is 0 if num of 1's in the data bits is odd. Mark: parity
bit is always 1. Space: Parity bit is always 0. Mark and Space Parity do not allow for error detection.
Stop Bits
1
2
Stop bits indicate the end of a serial data packet. (A.start bit indicates the beginning). The standard
setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit.
www.kontron.com
// 99
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Flow Control
None
Hardware
RTS/CTS
Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers
are full, a 'stop' signal can be sent to stop the data flow. Once the buffers are empty, a 'start' signal
can be sent to restart the flow. Hardware flow control uses two wires to send start/stop signals.
VT-UTF8 Combo Key Sup
Disabled
Enabled
Enable VT-UTF8 Combination Key Support for ANSI/VT100 terminals
Recorder Mode
Disabled
Enabled
With this mode enabled only text will be sent. This is to capture Terminal data.
Resolution 100×31
Disabled
Manual
Enables or disables extended terminal resolution
Legacy OS Redirection
Resolution
80x24
80x25
On Legacy OS, the Number of Rows and Columns supported redirection
Putty KeyPad
VT100
LINUX
XTERMR6
SCO
ESCN
VT400
Select FunctionKey and KeyPad on Putty.
Redirection After BIO
Always
Enable
BootLoader
The Settings specify if Bootloader is selected then legacy console redirection is disabled before booting
to legacy OS. Default value is Always Enable which means Legacy console Redirection is enabled for
Legacy OS.
www.kontron.com
// 100
COMe-bBD6 User Guide Rev. 1.4
6.5.2.19 Legacy Console Redirection Settings
Figure 33: Legacy Console Redirection Settings Menu Screen
Table 60: Legacy Console Redirection Settings Features List
Feature
Options
Description
Legacy Serial Redirection
Port
COM1
COM2
COM3 (Disabled)
COM4 (Disabled)
Select a COM port to display redirection of Legacy OS and Legacy OPROM Messages
www.kontron.com
// 101
COMe-bBD6 User Guide Rev. 1.4
6.5.2.20 Out-of-Band Management Console Redirection Settings
Figure 34: Out-of-Band Management Console Redirection Settings Menu Screen
Table 61: Out-of-Band Management Console Redirection Settings Features List
Feature
Options
Description
Out-of-Band Mgmt Port
COM1
COM2
COM3 (Disabled)
COM4 (Disabled)
Microsoft Windows Emergency Management Services (EMS) allows for remote
management of a Windows Server OS through a serial port.
Terminal Type
VT100
VT100+
VT-UTF8
ANSI
VT-UTF8 is the preferred terminal type for out-of-band management. The next best choice
is VT100+ and then VT100. See above, in Console Redirection Settings page, for more Help
with Terminal Type/Emulation.
Bits per second
9600
19200
57600
115200
Selects serial port transmission speed. The speed must be matched on the other side. Long
or noisy lines may require lower speeds.
Flow Control
None
Hardware RTS/CTS
Software Xon/Xoff
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a 'stop' signal can be sent to stop the data flow. Once the buffers
are empty, a 'start' signal can be sent to restart the flow. Hardware flow control uses two
wires to send start/stop signals.
www.kontron.com
// 102
COMe-bBD6 User Guide Rev. 1.4
6.5.2.21 PCI Subsystem Settings
Figure 35: PCI Subsystem Settings Menu Screen
Table 62: PCI Subsystem Settings Features List
Feature
Options
Description
PCI Latency Timer
32 PCI Bus Clocks
…
248 PCI Bus Clocks
Value to be programmed into PCI Latency Timer Register.
PCI-X Latency Timer
…
64 PCI Bus Clocks
…
248 PCI Bus Clocks
Value to be programmed into PCI Latency Timer Register.
VGA Palette Snoop
Disabled
Enabled
Enables or Disables VGA Palette Registers Snooping.
PERR# Generation
Disabled
Enabled
Enables or Disables PCI Device to Generate PERR#.
SERR# Generation
Disabled
Enabled
Enables or Disables PCI Device to Generate SERR#.
Above 4G Decoding
Disabled
Enabled
Enables or Disables 64bit capable Devices to be Decoded in Above 4G Address Space
(Only if System Supports 64bit PCI Decoding).
SR-IOV Support
Disabled
Enabled
If system has SR-IOV capable PCIe Devices, this option Enables or Disables Single Root IO
Virtualization Support.
www.kontron.com
// 103
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Don’t Reset VC-TC
Mapping
Disabled
Enabled
If system has Virtual Channels, Software can reset Traffic Class mapping through Virtual
Channels, to it’s default state. Setting this option to Enabled will not modify VC
Resources.
www.kontron.com
// 104
COMe-bBD6 User Guide Rev. 1.4
6.5.2.22 PCI Express Settings
Figure 36: PCI Express Settings Menu Screen
Table 63: PCI Express Settings Features List
Feature
Options
Description
Relaxed Ordering
Disabled
Enabled
Enables or Disables PCI Express Device Relaxed Ordering.
Extended Tag
Disabled
Enabled
If ENABLED allows Device to use 8-bit Tag field as a requester.
No Snoop
Disabled
Enabled
Enables or Disables PCI Express No Snoop option.
Maximum Payload
Auto
128 Bytes
…
2048 Bytes
4096 Bytes
Set Maximum Payload of PCI Express Device or allow System BIOS to select the value.
Extended Synch
Disabled
Enabled
If ENABLED allows generation of Extended Synchronization patterns.
Link Training Retry
Disabled
2
3
5
Defines number of Retry Attempts software will take to retrain the link if previous training
attempt was unsuccessful.
www.kontron.com
// 105
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Link Training Timeout (uS)
1000
Defines number of Microseconds software will wait before polling ‘Link Training’ bit in Link
Status register. Value range from 10 to 10000 uS.
Unpopulated Links
Keep Link ON
Disable Link
In order to save power, software will disable unpopulated PCI Express links, if this option set
to ‘Disable Link’.
Restore PCIE Registers
Disabled
Enabled
On non-PCI Express aware OS’s (Pre Windows Vista) some devices may not be correctly
reinitialized after S3. Enabling this restors PCI Express device configurations on S3 resume.
Warning: Enabling this may cause issues with other hardware after S3 resume.
www.kontron.com
// 106
COMe-bBD6 User Guide Rev. 1.4
6.5.2.23 PCI Express Gen 2 Settings
Figure 37: PCI Express Gen 2 Settings Menu Screen
Table 64: PCI Express Gen 2 Settings Features List
Feature
Options
Description
Completion Timeout
Default
Shorter
Longer
Disabled
In device Functions that support Completion Timeout programmability, allows system
software to modify the Completion Timeout value. ‘Default’ 50us to 50ms. If ‘Shorter’ is
selected, software will use shorter timeout ranges supported by hardware. If ‘Longer’ is
selected, software will use longer timeout ranges.
ARI Forwarding
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, the Downstream Port disables its
traditional Device Number field being 0 enforcement when turning a type1
Configuration Request into a type0 Configuration Request, permitting access to
Extended Functions in an ARI Device immediately below the Port. Default value:
Disabled
AtomicOp Requester Enable
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, this function initiates AtomicOp Requests
only if Bus Master Enable bit is in the Command Register Set.
AtomicOp Egress Blocking
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, outbound AtomicOp Requests via Egress
Ports will be blocked.
IDO Request Enable
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, this permits setting the number of IDBased Ordering (IDO) bit (Attribute[2]) requests to be initiated.
IDO Completion Enable
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, this permits setting the number of IDBased Ordering (IDO) bit (Attribute[2]) requests to be initiated.
www.kontron.com
// 107
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
LTR Mechanism Enable
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, this enables the Latency Tolerance
Reporting (LTR) Mechanism.
End-End TLP Prefix Blocking
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, this function will block forwarding of
TLPs containing End-End TLP Prefixes.
Target Link Speed
Auto
Force to 2.5 GT/s
Force to 5.0 GT/s
If supported by hardware and set to ‘Force to 2.5 GT/s’ for Downstream Ports, this sets
an upper limit on Link operational speed by restricting the values advertised by the
Upstream component in its training sequences. When ‘Auto’ is selected HW initialized
data will be used.
Clock Power Management
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, the device is permitted to use CLKREQ#
signal for power management of Link clock in accordance to protocol defined in
appropriate for factor specification.
Compliance SOS
Disabled
Enabled
If supported by hardware and set to ‘Enabled’, this will force LTSSM to send SKP
Ordered Sets between sequences when sending Compliance Pattern or Modified
Compliance Pattern.
Hardware Autonomous Width
Enabled
Disabled
If supported by hardware and set to ‘Disabled’, this will disable the hardware’s ability to
change link width except width size reduction for the purpose of correcting unstable
link operation.
Hardware Autonomous Speed
Enabled
Disabled
If supported by hardware and set to ‘Disabled’, this will disable the hardware’s ability to
change link speed except speed rate reduction for the purpose of correcting unstable
link operation.
www.kontron.com
// 108
COMe-bBD6 User Guide Rev. 1.4
6.5.2.24 PCI Hot-Plug Settings
Figure 38: PCI Hot-Plug Settings Menu Screen
Table 65: PCI Hot-Plug Settings Features List
Feature
Options
Description
BIOS Hot-Plug Support
Disabled
Enabled
If ENABLED allows BIOS build in Hot-Pug support. Use this feature if OS does not support
PCI Express and SHPC hot-plug natively.
PCI Buses Padding
1
2
3
4
5
Padd PCI Buses behind the bridge for Hot-Plug.
I/O Resources Padding
4K
8K
16 K
32 K
Padd PCI I/O Resources behind the bridge for Hot-Plug.
MMIO 32 bit Resources Padding
…
16 M
…
Padd PCI MMIO 32-bit Resources behind the bridge for Hot-Plug.
PFMMIO 32 bit Resources
Padding
…
16 M
…
Padd PCI MMIO 32-bit Prefetchable Resources behind the bridge for Hot-Plug.
www.kontron.com
// 109
COMe-bBD6 User Guide Rev. 1.4
6.5.2.25 Network Stack Configuration
Figure 39: Network Stack Configuration Menu Screen
Table 66: Network Stack Configuration Features List
Feature
Options
Description
Network Stack
Disabled
Enabled
Enable/Disable UEFI Network Stack
www.kontron.com
// 110
COMe-bBD6 User Guide Rev. 1.4
6.5.2.26 CSM Configuration
Figure 40: CSM Configuration Menu Screen
Table 67: CSM Configuration Features List
Feature
Options
Description
CSM Support
Disabled
Enabled
Enables/Disables CSM Support.
GateA20 Active
Upon Request
Always
UPN REQUEST – GA20 can be disabled using BIOS services. ALWAYS – do not allow disabling
GA20; this option is useful when any RT code is executed above 1MB.
Option ROM Messages
Keep Current
Force BIOS
Set display mode for Option ROM
INT19 Trap Response
Immediate
Postponed
BIOS reaction on INT19 trapping by Option ROM: IMMEDIATE – execute the trap right away;
POSTPONED – execute the trap during legacy boot.
Boot option filter
UEFI and Legacy
Legacy only
UEFI only
This option controls Legacy/UEFI ROMs priority
Network
Do not launch
UEFI
Legacy
Controls the execution of UEFI and Legacy PXE OpROM
Storage
Do not launch
UEFI
Legacy
Controls the execution of UEFI and Legacy Storage OpROM
www.kontron.com
// 111
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Video
Do not launch
UEFI
Legacy
Controls the execution of UEFI and Legacy Video OpROM
Other PCI devices
Do not launch
UEFI
Legacy
Determines OpROM execution policy for devices other than Network, Storage, or Video
www.kontron.com
// 112
COMe-bBD6 User Guide Rev. 1.4
6.5.2.27 NVMe Configuration
Figure 41: NVMe Configuration Menu Screen
www.kontron.com
// 113
COMe-bBD6 User Guide Rev. 1.4
6.5.2.28 Advanced USB Configuration
Figure 42: Advanced USB Configuration Menu Screen
Table 68: Advanced USB Configuration Features List
Feature
Options
Description
Legacy USB Support
Enabled
Disabled
AUTO
Enables Legacy USB support. AUTO option disables legacy support if no USB devices are connected.
DISABLE option will keep USB devices available only for EFI applications.
EHCI Hand-off
Disabled
Enabled
This is a workaround for OSes without EHCI hand-off Support. The EHCI ownership change should be
claimed by EHCI driver.
USB Mass Storage Driver
Support
Disabled
Enabled
Enable/Disable USB Mass Storage Driver Support.
Port 60/64 Emulation
Disabled
Enabled
Enables I/O port 60h/64h emulation support. This should be enabled for the complete USB keyboard
legacy support for non-USB aware OSes.
USB transfer time-out
1sec
…
20sec
The time-out value for Control, Bulk and Interrupt transfers.
Device reset time-out
10sec
20sec
…
USB mass storage device Start Unit command time-out.
Device power-up delay
Auto
Manual
Maximum time the device will take before it properly reports itself to the Host controller. 'Auto' uses
default value: for a Root port it is 100ms, for a Hub port the delay is taken from Hub descriptor.
www.kontron.com
// 114
COMe-bBD6 User Guide Rev. 1.4
6.5.3 Intel RC Setup
Figure 43: Intel RC Setup Menu Screen
www.kontron.com
// 115
COMe-bBD6 User Guide Rev. 1.4
6.5.3.1 Processor Configuration
Figure 44: Processor Configuration Menu Screen
Table 69: Processor Configuration Features List
Feature
Options
Description
Hyper-Threading (ALL)
Disabled
Enabled
Enables Hyper Threading (software Method to Enable/Disable Logical Processor threads.
Monitor/Mwait
Disabled
Enabled
Enable or Disable the Monitor/Mwait instruction
Execute Disable Bit
Disabled
Enabled
When disabled, forces the XD feature flag to always return 0.
Enable Intel TXT Support
Disabled
Enabled
Enables Intel Trusted Execution Technology Configuration. Please disable “EV DFX
Features” when TXT is enabled.
VMX
Disabled
Enabled
Enables the Vanderpool Technology, takes effect after reboot.
Enable SMX
Disabled
Enabled
Enables Safer Mode Extensions.
Lock Chipset
Disabled
Enabled
Lock or Unlock chipset
MSR Lock Control
Disabled
Enabled
Enable – MSR 3Ah, MSR 0E2h and CSR 80h will locked. Power Good reset os needed to
remove lock bits.
www.kontron.com
// 116
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
PPIN Control
Unlock/Disabled
Unlock/Enabled
Unlock and Enable/Disable PPIN Control
DEBUG INTERFACE
Disable
Enable
Auto
MSR 0C80h bit[0], When set enables the debug features.
Hardware Prefetcher
Enable
Disable
= MLC Streamer Prefetcher (MSR 1A4h Bit[0])
Adjacent Cache Prefetch
Enable
Disable
= MLC Spatial Prefetcher (MSR 1A4h Bit[1])
DCU Streamer Prefetcher
Enable
Disable
DCU streamer prefetcher is an L1 data cache prefetcher (MSR 1A4h Bit[2]).
DCU IP Prefetcher
Enable
Disable
DCU IP prefetcher is an L1 data cache prefetcher (MSR 1A4h Bit[3]).
DCU Mode
32KB 8Way Without
ECC
16KB 4Way With ECC
MSR 31h Bit[0] – A write of 1 selects the DCU mode as 16KB 4-way with ECC.
Direct Cache Access (DCA)
Disable
Enable
Auto
Enables Direct Cache Access
DCA Prefetch Delay
…
32
…
DCA Prefetch Delay Help
X2aPIC
Disable
Enable
Enable/disable extended APIC support
X2aPIC_OPT_OUT Flag
Disabled
Enabled
Enable/disable X2aPIC_OPT_OUT support flag
AES-NI
Disabled
Enabled
Down Stream PECI
Disabled
Enabled
Enable PCIe Down Stream PECI Write
IIO LLC Ways [19:0] (Hex)
0
MSR CBO_SLICEO_CR_IIO_LLC_WAYS bitmask
QLRU Config [63:32] (Hex)
0
VIRTUAL_MSR _CR_QLRU_CONFIG bitmask
QLRU Config [31:0] (Hex)
0
VIRTUAL_MSR _CR_QLRU_CONFIG bitmask
SMM Save State
Enable
Disable
Enable or Disable the SMM Save State Feature
Targeted Smi
Enable
Disable
Enable or Disable Targeted Smi Feature
www.kontron.com
// 117
COMe-bBD6 User Guide Rev. 1.4
6.5.3.2 Pre-Socket Configuration
Figure 45: Pre-Socket Configuration Menu Screen
www.kontron.com
// 118
COMe-bBD6 User Guide Rev. 1.4
6.5.3.3 CPU Socket Configuration
Figure 46: CPU Socket Configuration Menu Screen
Table 70: CPU Socket Configuration Features List
Feature
Options
Description
Cores Enabled
0
Number of Cores to Enable. 0 means all cores. 8 Cores available.
IOT Cfg Cbo Bitmap(Hex)
0
Each bit enables IOT/OCLA for a CBo.
www.kontron.com
// 119
COMe-bBD6 User Guide Rev. 1.4
6.5.3.4 Advanced Power Management Configuration
Figure 47: Advanced Power Management Configuration Menu Screen
Table 71: Advanced Power Management Configuration Features List
Feature
Options
Description
LOT26 Enable
Disable
Enable
For HEDT *only*, select whether VR power is turned off to empty DIMM channels.
UFS
Enabled
Disabled
Setting in PCU_MISC_CONFIG Bit[28]
CPU PM Tuning
Auto
Manual
If selected as ‘AUTO’, all bits in MSR 1FCh keeping value as PO.
EIST (P-states)
Disable
Enable
When enabled, OS sets CPU frequency according load. When disabled, CPU frequency is set at max
non-turbo.
Config TDP
Disable
Enable
Option to disable/enable Config TDP
IOTG Setting
Disable
Enable
IOTG Setting via sticky scratch pad register
Uncore CLR Freq OVRD
Auto
Manual
Override Uncore max CLR Freq ratio programming to MSR 0x620 bits[6:0]
www.kontron.com
// 120
COMe-bBD6 User Guide Rev. 1.4
6.5.3.5 CPU P State Control
Figure 48: CPU P State Control Menu Screen
Table 72: CPU P State Control Features List
Feature
Options
Description
P State Domain
ALL
ONE
Per Logical: indicates the P-state domain for each logical proc in the system.
Per Package: all procs indicate the same domain in the same package.
P-state coordination
HW_ALL
SW_ALL
SW_ANY
HW_ALL (hardware) coordination is recommended over SW_ALL an SW_ANY
(software coordination).
SINGLE_PCTL
no
yes
MSR_CR_MISC_PWR_MGMT 0x1AA Bit[0]: SINGLE_PCTL_EN
SPD
Disable
Enable
PCU_MISC_CONFIG Bit[30]: SPD
PL2_SAFETY_NET_ENABLE
Disable
Enable
PCU_MISC_CONFIG Bit[1]: PL2_SAFETY_NET_ENABLE
Energy efficient P-state
Disable
Enable
Enable/Disable Energy efficient P-state feature. When set to 0, will disable access to
ENERGY_PERFORMANCE_BIAS MSR and CPUID Function 6 EAX[3] will read 0
indicating nosupport for Energy Efficient policy setting. When set to 1 willenable
access to ENERGY_PERFORMANCE_BIAS MSR 1B0h and CPUID Function 6 EAX[3]
will read 1 indicating Energy EfficientPolicy setting is supported.
Boot performance mode
Max Performance
Max Efficient
Select the performance state that the BIOS will set before OS handoff.
www.kontron.com
// 121
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Turbo Mode
Disable
Enable
Turbo mode allows a CPU logical processor to execute a higher frequency when
enough power is available not exceed CPU defined limits.
www.kontron.com
// 122
COMe-bBD6 User Guide Rev. 1.4
6.5.3.6 XE Ratio Limit
Figure 49: XE Ratio Limit Menu Screen
Table 73: XE Ration Limit Features List
Feature
Options
Description
Overclocking Lock
Disable
Enable
Enable/Disable Overclocking.
www.kontron.com
// 123
COMe-bBD6 User Guide Rev. 1.4
6.5.3.7 CPU HWPM State Control
Figure 50: CPU HWPM State Control Menu Screen
Table 74: CPU HWPM State Control Features List
Feature
Options
Description
Enable CPU HWPM
Disable
HWPM NATIVE MODE
HWPM OOB MODE
Enable CPU HWPM for CPU for better Energy performance
Enable CPU Autonomous
Cstate
Disable
Enable
Enable CPU Autonomous Cstate which is CPU converst HALT instruction to MWAIT
www.kontron.com
// 124
COMe-bBD6 User Guide Rev. 1.4
6.5.3.8 CPU C State Control
Figure 51: CPU C State Control Menu Screen
Table 75: CPU C State Control Features List
Feature
Options
Description
C2C3TT
0
Default = 0, means [AUTO]. C2 to C3 Transition Timer, PPDN_INIT = 1:10:1:74
Bit[11:0].
CPU C State
Disable
Enable
Enables the Enhanced Cx state of the CPU, takes effect after reboot.
Package C State limit
C0/C1 state
C2 state
C6(non Retention) state
C6(Retention) state
No Limit
Package C State limit
CPU C3 report
Disable
Enable
Enable/Disable CPU C3(ACPI C2) report to OS. Recommended to be disabled.
CPU C6 report
Disable
Enable
Enable/Disable CPU C6(ACPI C2) report to OS Recommended to be enabled.
Enhanced Halt State (C1E)
Disable
Enable
Enables the Enhanced C1E state of the CPU, takes effect after reboot.
OS ACPI Cx
ACPI C2
Report CC3/CC6 to OS ACPI C2 or ACPI C3
www.kontron.com
// 125
COMe-bBD6 User Guide Rev. 1.4
6.5.3.9 CPU T State Control
Figure 52: CPU T State Control Menu Screen
Table 76: CPU T State Control Features List
Feature
Options
Description
ACPI T-States
Disable
Enable
Enable/Disable CPU throttling by OS. Throttling reduces power consumption.
www.kontron.com
// 126
COMe-bBD6 User Guide Rev. 1.4
6.5.3.10 CPU Thermal Management
Figure 53: CPU Thermal Management Menu Screen
Table 77: CPU Thermal Management Features List
Feature
Options
Description
Bi-directional PROCHOT#
Output-only
Disable
Bidirectional (normal input response)
Input-only
When a processor thermal sensor trips (either core), the PROCHOT#
will be driven. If bi-direction is enabled, external agents can drive
PROCHOT# to throttle the processor.
Thermal Monitor
Disable
Enabled
Enable/Disable Thermal Monitor
PROCHOT RESPONSE
Pn clamping
Pm clamping
Force CPU to throttle to a lower power condition such as Pn/Pm by
asserting PROCHOT#. MSR 0x1FC [26] =1: go to Pm(min freq) on
PROCHOT; =0 go to Pn (max efficient freq).
Use PCH_HOT
Disable
Enabled
Pcode is allowed to use PCH_HOT pin information for thermal
management
Use PCH Temp From ME
Disable
Enabled
Pcode is allowed to use PCH Temperature provided by ME
CPU to PCH Throttle
Disable
Enabled
Enable Pcode to throttle PCH
www.kontron.com
// 127
COMe-bBD6 User Guide Rev. 1.4
6.5.3.11 CPU Advanced PM Turning
Figure 54: CPU Advanced PM Turning Menu Screen
www.kontron.com
// 128
COMe-bBD6 User Guide Rev. 1.4
6.5.3.12 Energy Perf BIAS
Figure 55: Energy Perf BIAS Menu Screen
Table 78: Energy Perf BIAS Features List
Feature
Options
Description
Energy Performance Tuning
Enable
Disable
Selects whether BIOS or Operating System chooses energy
performance bias tunning.
Energy Performance BIAS setting.
Performance
Balance Performance
Balance Power
Power
Power/Performance Switch
Disable
Enabled
MSR 1FCh Bit[24] = PWR_PERF_TUNING_ENABLE_DYN_SWITCHING
Workload Configuration
UMA
NUMA
Optimization for the workload characterization. Balanced is
recommended.
Averaging Time Window
23
This is used to control the effective window of the average for C0 and
P0 time
P0 TotalTimeThreshold Low
35
The HW switching mechanism DISABLES the performance setting (0)
when the total P0 time is less than this threshhold
P0 TotalTimeThreshold High
58
The HW switching mechanism ENABLES the performance setting (0)
when the total P0 time is greater than this threshhold
www.kontron.com
// 129
COMe-bBD6 User Guide Rev. 1.4
6.5.3.13 Program PowerCTL_MSR
Figure 56: Program PowerCTL_MSR Menu Screen
Table 79: Program PowerCTL_MSR Features List
Feature
Options
Description
PKG C-state Lat. Neg.
Enable
Disable
MSR 1FCh Bit[30] = PCH_NEG_DISABLE
LTR Software Input
Take SW LTR input.
Ignore SW LTR input.
MSR 1FCh Bit[28] = LTR_SW_DISABLE. Disable = Ignore SW LTR input.
SAPM Control
Enable
Disable
MSR 1FCh Bit[22] = PWR_PERF_TUNING_DISABLE_SAPM_CTRL
PHOLD_SR
Enable
Disable
MSR 1FCh Bit[17] = PHOLD_SR_Disable
PHOLD_CST_PREVENTION_INIT
Enable
Disable
MSR 1FCh Bit[16] = PHOLD_CST_PREVENTION_INIT
FAST_Brk_Int_En
Enable
Disable
MSR 1FCh Bit[4] = FAST_Brk_Int_En. Disable = Use ‘fast’ VID swing
rate.
FAST_Brk_Snp_En
Enable
Disable
MSR 1FCh Bit[3] = FAST_Brk_Snp_En. Disable = Use ‘fast’ VID swing
rate.
Energy Efficient Turb
Enable
Disable
Energy Efficient Turbo Disable, MSR 0x1FC [19]
www.kontron.com
// 130
COMe-bBD6 User Guide Rev. 1.4
6.5.3.14 Program PPO_CURT_CFG_CTRL_MSR
Figure 57: Program PPO_CURT_CFG_CTRL_MSR Menu Screen
Table 80: Program PPO_CURT_CFG_CTRL_MSR Features List
Feature
Options
Description
PPO Current_Cfg_Ctl Ovrd
Auto
Manual
Allows manual overrides for
Primary_Plane_Current_Config_Control
Current Config
Disabled
Enable
0 – Deafult, do nothing; 1 – Manual, override Current limitation
in 1/8 A increments.
www.kontron.com
// 131
COMe-bBD6 User Guide Rev. 1.4
6.5.3.15 PSI Config
Figure 58: PSI Config Menu Screen
Table 81: PSI Config Features List
Feature
Options
Description
PSI3 Threshold
1
PSI3 Threshold
PSI2 Threshold
5
PSI2 Threshold
PSI1 Threshold
20
PSI1 Threshold
Lock Indication
Disable
Enable
This bit will lock the CURRENT_LIMIT settings in this register and
will also lock this setting
www.kontron.com
// 132
COMe-bBD6 User Guide Rev. 1.4
6.5.3.16 Program CSR_ENTRY_CRITERIA
Figure 59: Program CSR_ENTRY_CRITERIA Menu Screen
Table 82: Program CSR_ENTRY_CRITERIA Features List
Feature
Options
Description
PKG_CST_ENTRY_CRITERIA OVRD
Auto
Manual
Allows manual overrides for PKG_CST_ENTRY_CRITERIA_MASK
www.kontron.com
// 133
COMe-bBD6 User Guide Rev. 1.4
6.5.3.17 CPU Advanced PM Turning
Figure 60: CPU Advanced PM Turning Menu Screen
Table 83: CPU Advanced PM Turning Features List
Feature
Options
Description
QPI_0_IN
Disable
IN_L1
QPI_0 must be in L0s or L1. ‘Both’ = keeps default settings
CPU0 QPI_1_IN
Disable
IN_L1
QPI_1 must be in L0s or L1. ‘Both’ = keeps default settings
CPU0 QPI_2_IN
Disable
IN_L1
QPI_2 must be in L0s or L1. ‘Both’ = keeps default settings
PCIE Port0 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port1 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port2 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port3 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port4 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
www.kontron.com
// 134
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
PCIE Port5 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port6 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port7 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port8 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port9 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
PCIE Port10 PCIE_IN
Disable
IN_L1
If IN_L1, MSB = PCIe10. LSB-PCIe_10. LSB = PCIe_0.
www.kontron.com
// 135
COMe-bBD6 User Guide Rev. 1.4
6.5.3.18 Program CSR_SWLTROVRD
Figure 61: Program CSR_SWLTROVRD Menu Screen
Table 84: Program CSR_SWLTROVRD Features List
Feature
Options
Description
Snoop Latency Valid
Disable
Enable
When this bit is set to 0b, PCODE will ignore the Snoop Latency
override value
Snoop Latency Override
Disable
Enable
Force PCODe to always use values provided in SW_LTR_OVRD
Snoop Latency Multiplier
0
Value is multipled by to yield a time value
Snoop Latency Value
0
Latency requirement for Snoop requests
Non-Snoop Latency Value
Disable
Enable
When this bit is set to 0b, PCODE will ignore the Non-Snoop
Latency override value
Non-Snoop Latency Override
Disable
Enable
Force PCODe to always use values provided in SW_LTR_OVRD
NonSnoop LatencyMultiplier
0
Value is multipled by to yield a time value
Non-Snoop Latency Value
0
Latency requirement for Non-Snoop requests
www.kontron.com
// 136
COMe-bBD6 User Guide Rev. 1.4
6.5.3.19 Program MSR VR_MISC_CONFIG
Figure 62: Program MSR VR_MISC_CONFIG Menu Screen
Table 85: Program MSR VR_MISC_CONFIG Features List
Feature
Options
Description
Override VR CONFIG1
Disable
Enable
Enable Override Thermal VR CONFIG1 parameters
www.kontron.com
// 137
COMe-bBD6 User Guide Rev. 1.4
6.5.3.20 Program MSR VR_MISC_CONFIG2
Figure 63: Program MSR VR_MISC_CONFIG2 Menu Screen
Table 86: Program MSR VR_MISC_CONFIG2 Features List
Feature
Options
Description
Override VR CONFIG2
Disable
Enable
Enable Override Thermal VR CONFIG2 parameters
www.kontron.com
// 138
COMe-bBD6 User Guide Rev. 1.4
6.5.3.21 DRAM RAPL Configuration
Figure 64: DRAM RAPL Configuration Menu Screen
Table 87: DRAM RAPL Configuration Features List
Feature
Options
Description
DRAM RAPL Baseline
Disable
DRAM RAPL Mode 0
DRAM RAPL Mode 1
DRAM RAPL Baseline enabled and baseline mode
Override BW_LIMIT_TF
1
Allows custom tuning of BW_LIMIT_TF when DRAM RAPL is
enabled
DRAM RAPL Extended Range
Disable
Enable
Select DRAM RAPL Extended Range
www.kontron.com
// 139
COMe-bBD6 User Guide Rev. 1.4
6.5.3.22 Socket RAPL Config
Figure 65: Socket RAPL Config Menu Screen
Table 88: Socket RAPL Config Features List
Feature
Options
Description
FAST_RAPL_NSTRIKE_PL2_DUTY_CYCLE
64
FAST_RAPL_NSTRIKE_PL2_DUTY_CYCLE value between 25 (10%) –
64 (25%)
Turbo Pwr Limit Lock
Disable
Enable
Enable/Disable locking of turbo settings. When enabled,
TURBO_POWER_LIMIT MSR will be locked and a reset will be
required to unlock the register.
Long Pwr Limit Ovrd
Disable
Enable
Enable/Disable Long Term Power Limit override. If this option is
disabled, BIOS will program the deafult values for Long Term Power
Limit and Long Term Power Limit Time Window.
Long Dur Pwr Limit
0
Turbo Mode Long Duration Power Limit (aka Power Limit 1) in
Watts. The value may vary from 0 to Fused Value. If the value is 0,
the fused value will be programmed. A value greater than fused TDP
value will not be programmed.
Long Dur Time Window
1
Long Duration Time Window (aka Power Limit 1 Time) value in
seconds. The value may vary from 0 to 56. Indicates the time
window over which TDP value should be maintained. If the value is
0, the fused value will be programmed.
www.kontron.com
// 140
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Pkg Clmp Lim1
Bewtee P1/P0
Below P1
Pkg Clamping limit 1, Allow going below P1. 0: PBBM limited
between P1 and P0, 1: PBM can go below P1
Short Dur Pwr Limit En
Disable
Enable
Enable/Disable Short Duration Power Limit (aka Power Limit 2)
Short Dur Pwr Limit
0
Short Duration Power Limit (aka Power Limit 2) value in Watts. The
value may vary from 0 to 32767. If the value is 0, BIOS will program
this value as 125%TDP. Processor applies control policies such that
the package power does not exceed this limit.
Pkg Clmp Lim2
Bewtee P1/P0
Below P1
Pkg Clamping limit 2, Allow going below P1. 0: PBBM limited
between P1 and P0, 1: PBM can go below P1
www.kontron.com
// 141
COMe-bBD6 User Guide Rev. 1.4
6.5.3.23 Common RefCode Configuration
Figure 66: Common RefCode Configuration Menu Screen
Table 89: Common RefCode Configuration Features List
Feature
Options
Description
MMCFG Base
2G
1G
3G
Select MMCFG Base
MMIOBase
56T
48T
…
1T
MMIOH Base [63:32]; must be between 4032 – 4078
MMIO High Size
256G
128G
512G
1024G
Select MMIOH High Size
Isoc Mode
Disable
Isoc: Disable,Enable
MeSeg Mode
Disable
Enable
Auto
MeSeg: Disable,Enable
Numa
Disable
Enable
Enable or Disable Non uniform Memory Access (NUMA).
www.kontron.com
// 142
COMe-bBD6 User Guide Rev. 1.4
6.5.3.24 QPI Configuration
Figure 67: QPI Configuration Menu Screen
www.kontron.com
// 143
COMe-bBD6 User Guide Rev. 1.4
6.5.3.25 QPI General Configuration
Figure 68: QPI General Configuration Menu Screen
Table 90: QPI General Configuration Features List
Feature
Options
Description
Degrade Precedence
Topology Precedence
Feature Precedence
Choose Topology Precedence to degrade features if system
options are in conflict or choose Feature Precedence to degrade
topology if system options are in conflict.
Link Speed Mode
Slow
Fast
Select the QPI link speed as either the POR speed (Fast) or
default speed (Slow)
Link Frequency Select
6.4GB/s
8.0GB/s
9.6GB/s
Auto
Auto Limited
Allows for selecting the QPI Link Frequency
Link L0p Enable
Disable
Enable
Link L0p
Enable:Disable,Enable,Auto(default)
Link L1 Enable
Disable
Enable
Link L1
Enable:Disable,Enable,Auto(default)
Legacy VGA Socket
0
Socket that claims the legacy VGA range; valid values are 0-7; 0 is
default.
MMIO P2P Disable
no
yes
To disable MMIOL P2P traffic across Sockets. Default is NO to not
disable.
www.kontron.com
// 144
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
E2E Parity Enable
Disable
Enable
Enable/Disable E2E Parity.
COD Enable
Disable
Enable
Auto
Enable/disable Cluster on Die.
Early Snoop
Disable
Enable
Auto
Home Dir Snoop with I
Disable
Enable
Auto
Enable/disable Home Dir Snoop with IVT- Style OSB
QPI Debug Print Level
Fatal
Warning
Summary
Detail
All
QPI Debug Print Level Enable-Disable.
www.kontron.com
// 145
COMe-bBD6 User Guide Rev. 1.4
6.5.3.26 QPI Status
Figure 69: QPI Status Menu Screen
www.kontron.com
// 146
COMe-bBD6 User Guide Rev. 1.4
6.5.3.27 QPI Per Socket Configuration
Figure 70: QPI Per Socket Configuration Menu Screen
www.kontron.com
// 147
COMe-bBD6 User Guide Rev. 1.4
6.5.3.28 QPI Per Socket Configuration - CPU
Figure 71: QPI Per Socket Configuration - CPU Menu Screen
Table 91: QPI Per Socket Configuration - CPU Features List
Feature
Options
Description
Bus Resources Allocation
Ration
1
Bus resources allocation ratio, range 0 to 8
IO Resources Allocation
Ration
1
IO resources allocation ratio, range 0 to 8
MMIOL:Resources Allocation
Ratio
1
MMIOL resources allocation ratio, range 0 to 8
IIO Disable
no
Disable Ports and IIO without memory hotplug
Disable Ports Only with memory hotplug
Disable Ports and Clock Gate IIO
www.kontron.com
// 148
COMe-bBD6 User Guide Rev. 1.4
6.5.3.29 Memory Configuration
Figure 72: Memory Configuration Menu Screen
Table 92: Memory Configuration Features List
Feature
Options
Description
Enforce POR
Auto
Enforce POR
Disabled
Enforce Stretch Goals
Enable to enforce POR restrictions for DDR4 frequency and voltage programming
Memory Frequency
Auto
…
Reserved
Maximum Memory Frequency Selections in MHz. Do not select Reserved
MRC Promote Warnings
Disabled
Enabled
Determines if MRC warnings are promoted to system level
Promote Warnings
Disable
Enable
Determines if warnings are promoted to system level
Halt on mem Training Error Disabled
Enabled
Halt on mem Training Error Disable/Enable
Multi-Threaded MRC
Enable to execute the Memory Reference Code multi-threaded
www.kontron.com
Auto
Disabled
Enabled
// 149
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
ECC Support
Auto
Disable
Enable
Enable/disable DDR ECC Support
Enforce Timeout
Auto
Disable
Enable
Enable/disable forcing cold reset after 3 months
Enhanced Log Parsing
Disable
Enable
Enable additional output in debug log for easier machine parsing
Backside RMT
Auto
Disable
Enable
Enable Backside RMT
Rank Multiplication
Auto
Enabled
Force the Rank Multiplication factor for LRDIMM
LRDIMM Module Delay
Disabled
Auto
When Disabled, MRC will not use SPD bytes 90-95 for LRDIMM Module Delay. When
Auto, MRC will boundary check the values and use default values, if SPD is 0 or out
of range
MemTest
Auto
Disable
Enable
Enable/disable memory test during normal boot
MemTestLoops
1
Number of Memory test loops during normal boot, set to 0 to run memtest infinitely
Dram Maintenance Test
Auto
Disabled
Enabled
Dram Maintenance Test during normal boot
Memory Type
RDIMMs only
UDIMMs only
RDIMMs and UDIMMs
Selects the Memory type supported by this platform.
CECC WA CH Mask
10
CH bitmask to apply CECC WA. 1 bit per CH. Value 2 applies WA on CH1, 3 on CH0
and 1
Rank Margin Tool
Auto
Disabled
Enabled
Enables the rank margin tool to run after DDR4 memory training
RMT Pattern Length
32767
Sets the pattern length for the Rank Margin Tool
CMD Pattern Length
32767
Sets the pattern length for the Rank Margin Tool
Per Bit Margin
Auto
Disable
Enable
Enables the logging from the serial port of DDR Per Bit Margin Data
Training Result Offset
Config
Auto
Disabled
Enabled
Option to offset the final memory training results
Attempt Fast Boot
Auto
Disable
Enable
When enabled, portions of memory reference code will be skipped when possible to
increase boot speed
Attempt Fast Cold Boot
Auto
Disable
Enable
When enabled, portions of memory reference code will be skipped when possible to
increase boot speed
MemTest On Fast Boot
Auto
Disable
Enable
Enable/disable memory test during fast boot
RMT on Cold Fast Boot
Auto
Disable
Enable
Enable/Disable Rank Margin Tool on Cold Fast Boot
www.kontron.com
// 150
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
BDAT
Enabled
Disabled
Enable Disables BDAT
Data Scrambling
Auto
Disabled
Enabled
Enables data scrambling
Allow SBE during Training
Auto
Disabled
Enabled
Allow SBE during training knob enable/disable
CECC WA Control
Auto
Disabled
Enabled
This knob controls the CECC WA. Disabled by Default on L0 and Later Processor.
CAP ERR LOW feature
Auto
Disabled
Enabled
This knob controls the CAP ERR FLOW feature. Disabled by Default.
Scrambling Seed Low
41003
Low 32 bits of the scrambling seed
Scrambling Seed High
54165
High 32 bits of the scrambling seed
Enable ADR
Disabled
Hardware Triggered ADR
Software Triggered ADR
Enables the detecting and enabling of ADR
MC BGF threshold
0
The HA to MC BGF threshold is used for scheduling MC request in bypass condition.
DLL Reset Test
0
Set this to the number of loops to execute the DDL reset test. The test will execute
RMT for the provided number of loops without DLL resets and then it will exectue
RMT for the same number of loops with DLL resets.
MC ODT Mode
Auto
100 OHms
50 OHms
Select MC ODT Mode
Opp read during WMM
Auto
Disabled
Enabled
Enable/Disable issuing read commands opportunistically during WMM
Normal Operation
Duration
1024
Set normal operation duration interval (0 – 65535)
Number of Sparing
Transaction
4
Set number of sparing transactions interval (0 – 65535)
PSMI Support
Disabled
Enabled
PSMI Support Disable/Enable
C/A Parity Enable
Auto
Disabled
Enabled
Enable/Disable DDR4 Command Address Parity
SMB Clock Frequency
Auto
400 kHz
1 MHz
Sets DDR4 SMB Clock Frequencys For SPD ACCESS
DIMM Rank Enable Mask
Disabled
Enabled
Selects rank to enable/disable per DIMM
www.kontron.com
// 151
COMe-bBD6 User Guide Rev. 1.4
6.5.3.30 Memory Topology
Figure 73: Memory Topology Menu Screen
www.kontron.com
// 152
COMe-bBD6 User Guide Rev. 1.4
6.5.3.31 Memory Thermal
Figure 74: Memory Thermal Menu Screen
Table 93: Memory Thermal Features List
Feature
Options
Description
Set Throttling Mode
Disabled
OLTT
CLTT
Configure Thermal Throttling Mode. Select OLTT or CLTT mode.
Phase Shedding
Auto
Disabled
Enabled
DDR4 VR Static Phase Shedding Support. PS0: full-phase, PS1: single-phase, typically <18A load,
PS2: fixed loss, typically <5A load
Memory Power Savings
Mode
Auto
…
User Defined
Configures CKE and related Memory Power Savings Features
MDLL Off
Auto
Disabled
Enabled
Enable to shut down MDLL during SR
MEMHOT Throttling Mode Disabled
Output-only
Input-only
Configure MEMHOT Input and Output Mode: Mem Hot Sense Therm Throt or Mem Hot Output
Therm Throt.
Mem Electrical Throttling
Configure Memory Electrical Throttling
www.kontron.com
Disabled
Enabled
Auto
// 153
COMe-bBD6 User Guide Rev. 1.4
6.5.3.32 Memory Power Savings Advanced Options
Figure 75: Memory Power Savings Advanced Options Menu Screen
Table 94: Memory Power Savings Advanced Options Features List
Feature
Options
Description
CK in SR
Auto
Driven
Tri-State
Pulled Low
Pulled High
Configures CK behavior during self-refresh.
www.kontron.com
// 154
COMe-bBD6 User Guide Rev. 1.4
6.5.3.33 Memory Timings & Voltage Override
Figure 76: Memory Timings & Voltage Override Menu Screen
Table 95: Memory Timings & Voltage Override Features List
Feature
Options
Description
DIMM profile
Disabled
Manual
Selects the XMP profile to use
Memory Frequency
Auto
800
…
Maximum Memory Frequency Selections in Mhz. Do not select Reserved
www.kontron.com
// 155
COMe-bBD6 User Guide Rev. 1.4
6.5.3.34 Memory Map
Figure 77: Memory Map Menu Screen
Table 96: Memory Map Features List
Feature
Options
Description
Socket Interleave Below
4GB
Disable
Enable
Splits the 0-4GB address space between two sockets, so that both sockets get a
chunk of local memory below 4GB
Channel Interleaving
Auto
1-way Interleave
…
4-way Interleave
Select Channel Interleaving setting
Rank Interleaving
Auto
1-way Interleave
…
8-way Interleave
Select Rank Interleaving setting
IOT Memory Buffer
Reservation
0
Enable/Disable/Select IOT Memory Buffer Reservation
A7 Mode
Disable
Enable
A7 Mode Disable/Enable
www.kontron.com
// 156
COMe-bBD6 User Guide Rev. 1.4
6.5.3.35 Memory RAS Configuration
Figure 78: Memory RAS Configuration Menu Screen
Table 97: Memory RAS Configuration Features List
Feature
Options
Description
Correctable Error
Threshold
32767
Correctable Error Threshold (1 – 32767) used for sparing, tagging, and leaky bucket
Leaky bucket low bit
40
Leaky bucket low bit” (1 – 63)
Leaky bucket high bit
41
Leaky bucket high bit” (1 – 63)
DRAM Maintenance
Auto
MANUAL
Disable
Select Manual to customize DRAM Maintenance settings
Patrol Scrub
Disable
Enable
Enable/Disable Patrol Scrub
Patrol Scrub Interval
24
Selects the number of hours (1-24) required to complete full scrub. A value of zero means auto!
Demand Scrub
Disable
Enable
Enable/Disable Demand Scrub
Device Tagging
Disable
Enable
Enable/Disable Device Tagging
Memory Power
Management
Disable
Enable
Enable Memory power management for this platform
www.kontron.com
// 157
COMe-bBD6 User Guide Rev. 1.4
6.5.3.36 IIO Configuration
Figure 79: IIO Configuration Menu Screen
Table 98: IIO Configuration Features List
Feature
Options
Description
IIO PCIe Link on phase
Before memory chipset init
Post chipset init
Link training can be done either before memory chipset init or post chipset init
PCIe Train by BIOS
no
yes
Assume IIO is strapped for Wait-for-BIOS because straps are unreliable in A-O Silicon
PCIe Hot Plug
Disable
Enable
Auto
MANUAL
Enable/Disable PCIe Hot Plug globally
PCIe ACPI Hot Plug
Disable
Enable
Per-Port
Enable/Disable PCIe ACPI Hot Plug globally, or allow per-port control. When
Disabled, MSI is generated on HP event. When Enabled, _HPGPE message is
generated.
EV DFX Features
Disable
Enable
Set this option to allow DFX Lock Bits to remain clear
TX EQ WA
Enable
Disable
Use special table for TX_EQ and vendor specific cards
WA 4167453
Disable
Enable
Disable IIO VCP, Disable PHC VC1, set IIO VC1 & PCH VCP to TC2, clear
irp_misc_dfx0.force_no_snp_on_vc1_vcm
www.kontron.com
// 158
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
DMI Vc1 Control
Disable
Enable
Enable/Disable DMI Vc1
DMI Vcp Control
Disable
Enable
Enable/Disable DMI Vcp
DMI Vcm Control
Disable
Enable
Enable/Disable DMI Vcm
VC0 No-Snoop
Configuration
Disable
Enable
Enables No-Snoop on reads and writes for Vc0 traffic.
Gen3 Phase3 Loop Count
1
4
16
256
Skip Halt On DMI
Degradation
Disable
Enable
Enable this option to avoid the system to be halted on DMI width/link degradation
Power down unused ports
no
yes
Power down unused ports
SLD WA Revision
Auto
Rx Clock WA
Disable
Enable
Rx Clock WA
PCI-E ASPM Support
(Global)
Disable
L1 Only
This option enables / disables the ASPM support for all downstream devices.
PCIE Stop & Scream
Support
Disable
Enable
This option enables / disables PCIE Stop & Scream Support
Snoop Response Hold Off
6
Sets Snoop Response Hold Off value, 256 cycles as Default
www.kontron.com
// 159
COMe-bBD6 User Guide Rev. 1.4
6.5.3.37 IIO0 Configuration
Figure 80: IIO0 Configuration Menu Screen
Table 99: IIO0 Configuration Features List
Feature
Options
Description
IOU2 (IIO PCIe Port 1)
x4x4
x8
Auto
Selects PCIe port Bifurcation for selected slots(s)
IOU0 (IIO PCIe Port 2)
x4x4x4x4
x8x8
…
Selects PCIe port Bifurcation for selected slots(s)
IOU1 (IIO PCIe Port 3)
…
x16
Auto
Selects PCIe port Bifurcation for selected slots(s)
No PCIe port active ECOPCIe
ACPI Hot Plug
PCU Squelsh exit ignore option
Reset the SQ FLOP by CSR option
Workaround settings when no PCIe port active
IOU0 Non-Posted Prefetch
Enable
Disable
Enable/Disable IOU0 Non-Posted Prefetch
IOU1 Non-Posted Prefetch
Enable
Disable
Enable/Disable IOU1 Non-Posted Prefetch
IOU2 Non-Posted Prefetch
Enable
Disable
Enable/Disable IOU2 Non-Posted Prefetch
www.kontron.com
// 160
COMe-bBD6 User Guide Rev. 1.4
6.5.3.38 Socket 0 PcieD00F0 - Port 0/DMI
Figure 81: Socket 0 PcieD00F0 - Port 0/DMI Menu Screen
Table 100: Socket 0 PcieD00F0 - Port 0/DMI Features List
Feature
Options
Link Speed
Auto
Gen 1 (2.5 GT/s)
Gen 2 (5 GT/s)
Override Max Link Width
Auto
x1
…
x16
Override the max link width that was set by bifurcation
PCI-E Port DeEmphasis
-6.0 dB
-3.5 dB
De-Emphasis control (LNKCON2[6]) for this PCIe port.
PCI-E Port L0s Exit Latency
4uS – 8uS
The length of time this port requires to complete transition from L0s to L0
PCI-E Port L1 Exit Latency
<1uS
…
8uS – 16uS
…
>64uS
The length of time this port requires to complete transition from L1 to L0
Fatal Err Over
Disable
Enable
Enables forcing fatal error propogation to the IIO core error logic for this port
Non-Fatal Err Over
Disable
Enable
Enable forcing non-fatal error propogation to the IIO core error logic for this port
www.kontron.com
Description
// 161
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Corr Err Over
Disable
Enable
Enables forcing correctable error propogation to the IIO core error logic for this port
L0s Support
Disable
When disabled, IIO never puts its transmitter in L0s state
www.kontron.com
// 162
COMe-bBD6 User Guide Rev. 1.4
6.5.3.39 Socket 0 PcieD0XFX – Port XX
Figure 82: Socket 0 PcieD0XFX – Port XX Menu Screen
Table 101: Socket 0 PcieD0XFX – Port XX Features List
Feature
Options
Description
PCI-E Port
Auto
Enable
Disable
In auto mode the BIOS will remove the EXP port if there is no device or errors on
that device and the device is not HP capable. Disable is used to disable the port and
hide its CFG space.
Hot Plug Capable
Disable
Enable
This option specifies if the link is considered Hot Plug capable.
PCI-E Port Link
Enable
Disable
This option disables the link so that the no training occurs but the CFG space is still
active.
Link Speed
Auto
Gen 1 (2.5 GT/s)
Gen 2 (5 GT/s)
Gen 3 (8 GT/s)
Override Max Link Width
Auto
x1
…
x16
Override the max link width that was set by bifurcation
PCI-E Port DeEmphasis
-6.0 dB
-3.5 dB
De-Emphasis control (LNKCON2[6]) for this PCIe port.
www.kontron.com
// 163
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
PCI-E Port L0s Exit Latency
4uS – 8uS
The length of time this port requires to complete transition from L0s to L0
PCI-E Port L1 Exit Latency
<1uS
…
8uS – 16uS
…
>64uS
The length of time this port requires to complete transition from L1 to L0
Fatal Err Over
Disable
Enable
Enables forcing fatal error propogation to the IIO core error logic for this port
Non-Fatal Err Over
Disable
Enable
Enable forcing non-fatal error propogation to the IIO core error logic for this port
Corr Err Over
Disable
Enable
Enables forcing correctable error propogation to the IIO core error logic for this port
L0s Support
Disable
When disabled, IIO never puts its transmitter in L0s state
PM ACPI Mode
Disable
Enable
Gen3 Eq Mode
Auto
Enable Phase 0,1,2,3
Disable Phase 0,1,2,3
…
Alt Short Channel
PCIe Gen3 Adaptive Equilization Mode
Gen3 Spec Mode
Auto
0.70 July
0.70 Sept
0.71 Sept
PCIe Gen3 Spec Mode
Gen3 Phase2 Mode
Hardware Adaptive
Manual
Gen3 DN Tx Preset
Auto
P0 (-6.0/0.0 dB)
…
PCIe Gen3 Downstream Tx Preset
Gen3 DN Rx Preset
Auto
P0 (-6.0/0.0 dB)
…
PCIe Gen3 Downstream Rx Preset Hint
Gen3 UP Tx Preset
Auto
P0 (-6.0/0.0 dB)
…
PCIe Gen3 Upstream Tx Preset
Hide Port?
no
yes
User can force to hide this root port from OS
Pcie Ecrc
Disable
Enable
Auto
Enable/Disable Pcie Ercr Support for this port.
www.kontron.com
// 164
COMe-bBD6 User Guide Rev. 1.4
6.5.3.40 IOAT Configuration
Figure 83: IOAT Configuration Menu Screen
Table 102: IOAT Configuration Features List
Feature
Options
Description
Enable IOAT
Disable
Enable
Control to enable/disable IOAT devices
No Snoop
Disable
Enable
No Snoop Enable/Disable for each CB device
Disable TPH
Enable
Disable
TLP processing Hint disable
www.kontron.com
// 165
COMe-bBD6 User Guide Rev. 1.4
6.5.3.41 IIO General Configuration
Figure 84: IIO General Configuration Menu Screen
Table 103: IIO General Configuration Features List
Feature
Options
Description
TXT DPR memory setting
1M DPR
3M DPR
64M DPR
128M DPR
255M DPR
Allows selection of the TXT DPR size in system
IIO IOAPIC
Disable
Enable
Enable / Disable the IIO IOAPIC
www.kontron.com
// 166
COMe-bBD6 User Guide Rev. 1.4
6.5.3.42 Intel VT for Directed I/O (VT-d)
Figure 85: Intel VT for Directed I/O (VT-d) Menu Screen
Table 104: Intel VT for Direct I/O (VT-d) Features List
Feature
Options
Description
VTd Azalea VCp
Optimizations
Disable
Enable
Enable/Disable Azalea VCp Optimizations
Intel VT for Directed I/O
(VT-d)
Enable
Disable
Enable/Disable Intel Virtualization Technology for Directed I/O (VT-d) by reporting
the I/O device assignment to VMM through DMAR ACPI Tables.
ACS Control
Enable
Disable
Enable: Programs ACS only to Chipset Pcie Root Ports Bridges; Disable: Programs
ACS to all Pcie bridges
Interrupt Remapping
Enable
Disable
Enable/Disable VT_D Interrupt Remapping Support
Coherency Support (NonIsoch)
Enable
Disable
Enable/Disable Non-Isoch VT_D Engine Coherency support
Coherency Support (Isoch)
Enable
Disable
Enable/Disable Isoch VT_D Engine Coherency support
www.kontron.com
// 167
COMe-bBD6 User Guide Rev. 1.4
6.5.3.43 IIO South Complex Configuration
Figure 86: IIO South Complex Configuration Menu Screen
Table 105: IIO South Complex Configuration Features List
Feature
Options
Description
Disable SC GbE
Disable
Enable
Disables South Complex GbE completely
SC GbE PF0
Auto
Enable
Disable
Force Enable / Disable SC GbE physical function 0
SC GbE PF1
Auto
Enable
Disable
Force Enable / Disable SC GbE physical function 1
Disable SC CB3 DMA
Disable
Enable
Disables South Complex CB3 DMA completely
www.kontron.com
// 168
COMe-bBD6 User Guide Rev. 1.4
6.5.3.44 PCH Configuration
Figure 87: PCH Configuration Menu Screen
www.kontron.com
// 169
COMe-bBD6 User Guide Rev. 1.4
6.5.3.45 PCH Devices
Figure 88: PCH Devices Menu Screen
Table 106: PHC Devices Features List
Feature
Options
Description
Board Capacity
SUS_PWR_ON_ACK
DeepSx
Board Capability – SUS_PWR_DN_ACK -> Send Disabled to PCH, DeepSx -> Show
DeepSx Policies
DeepSx Power Policies
Disabled
Enabled in S5
Enabled in S4-S5
Enabled in S3-S4-S5
configure the DeepSx Mode configuration.
GP27 Wake From DeepSx
Enabled
Disabled
Wake from DeepSx by the assertion of GP27 pin
SMBUS Device
Disabled
Enabled
Enable/Disable SMBUS Device.
PCH Server Error Reporting
Mode (S
Disabled
Enabled
When enabled MCH is the final target of all errors otherwise SPCH is the final target
to all errors
PCH Display
Disabled
Enabled
Enables/Disables PCH Display
High Precision Timer
Disabled
Enabled
Enable or Disable the High Precision Event Timer.
www.kontron.com
// 170
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Boot Time with HPET Timer Disabled
Enabled
Boot time calculation with High Precision Event Timer enabled.
External SSC Enable –
CK420
Disabled
Enabled
Enable Spread Spectrum – only affects external clock generator
PCH state after G3
S0
S5
Last State
Select S0/S5 for ACPI state after a G3
PCH CRID
Disabled
Enabled
Enable/Disable PCH’s CRID
www.kontron.com
// 171
COMe-bBD6 User Guide Rev. 1.4
6.5.3.46 PCI Express Configuration
Figure 89: PCH Express Configuration Menu Screen
Table 107: PCH Express Configuration Features List
Feature
Options
Description
PCI-E ASPM Support
(Global)
Disabled
L1 Only
This option enables / disables the ASPM support for all downstream devices.
PCI-E Clock Gating
Disabled
Enabled
PCIE Clock Gating Enable/Disable for all PCH PCIE Ports.
DMI Link Extended Synch
Control
Disabled
Enabled
The control of Extended Synch on SB slide of the DMI Link.
Stop and Screame
Disabled
Enabled
When Enabled DS packets on DMI with the EP bit set, will have their UT bit set.
PCIe-USB Glitch W/A
Disabled
Enabled
PCIe-USB Glitch W/A for bad USB device(s) connected behind PCIE/PEG Port.
PCIe Root Port Function
Swapping
Disabled
Enabled
Enable PCIe root port function swapping feature to dynamically assign function 0 to
enabled root port.
www.kontron.com
// 172
COMe-bBD6 User Guide Rev. 1.4
6.5.3.47 PCI Express Root Port
Figure 90: PCH Express Root Port Menu Screen
Table 108: PCH Express Root Port Features List
Feature
Options
Description
PCI Express Root Port
Disabled
Enabled
Control the PCI Express Root Port.
L1 Substates
Disabled
…
L1.1 & L1.2
PCI Express L1 Substates settings.
URR
Disabled
Enabled
PCI Express Unsupported Request Reporting Enable/Disable.
FER
Disabled
Enabled
PCI Express Device Fatal Error Reporting Enable/Disable.
NFER
Disabled
Enabled
PCI Express Device Non-Fatal Error Reporting Enable/Disable.
CER
Disabled
Enabled
PCI Express Device Correctable Error Reporting Enable/Disable.
CTO
Disabled
Enabled
PCI Express Completion Timer T0 Enable/Disable.
SEFE
Disabled
Enabled
Root PCI Express System Error on Fatal Error Enable/Disable.
www.kontron.com
// 173
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
SENFE
Disabled
Enabled
Root PCI Express System Error on Non-Fatal Error Enable/Disable.
SECE
Disabled
Enabled
Root PCI Express System Error on Correctable Error Enable/Disable.
PME SCI
Disabled
Enabled
PCI Express PME SCI Enable/Disable.
Hot Plug
Disabled
Enabled
PCI Express Hot Plug Enable/Disable.
PCIe Speed
Auto
Gen1
Gen2
Configure PCIe Speed
PME Interrupt
Disabled
Enabled
PCI Express PME Interrupt Enable/Disable.
MSI
Disabled
Enabled
PCIE MSI Enable/Disable.
Extra Bus Reserved
0
Extra Bus Reserved (0-7) for bridges behind this root Bridge.
Reseved Memory
10
Reserved Memory and Prefetchable Memory (1-20MB) Range for this Root Bridge.
Reserved I/O
4
Reserved I/O (4K/8K/12K/16K/20K) Range for this Root Bridge.
www.kontron.com
// 174
COMe-bBD6 User Guide Rev. 1.4
6.5.3.48 PCH SATA Configuration
Figure 91: PCH SATA Configuration Menu Screen
Table 109: PCH SATA Configuration Features List
Feature
Options
Description
SATA Controller
Disabled
Enabled
Enable or Disable SATA Controller
Configure SATA as
IDE
AHCI
RAID
Identify the SATA port is connected to Solid State Drive or Hard Disk Drive
SATA test mode
Enabled
Disabled
Enable/Disable SATA test mode
SATA AHCI LPM
Disabled
Enabled
Enables/Disables Link Power Management
Support Aggressive Link
Power Mana
Disabled
Enabled
Enables/Disables SALP
Port
Disabled
Enabled
Enable or Disable SATA Port
Hot Plug
Disabled
Enabled
Designates this port as Hot Pluggable.
For each SATA Port:
www.kontron.com
// 175
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Configure as eSATA
Disabled
Enabled
Configures port as External SATA (eSATA)
Spin Up Device
Disabled
Enabled
If enabled for any of ports Staggered Spin Up will be performed and only the drivers
which have this option enabled will spin up at boot. Otherwise all drives spin up at
boot.
SATA Device Type
Hard Disk Drive
Solid State Drive
Identify the SATA port is connected to Solid State Drive or Hard Disk Drive
www.kontron.com
// 176
COMe-bBD6 User Guide Rev. 1.4
6.5.3.49 SATA Mode Options
Figure 92: SATA Mode Options Menu Screen
Table 110: SATA Mode Options Features List
Feature
Options
Description
SATA HDD Unlock
Disabled
Enabled
Enable: HDD password unlock is enabled in the OS
SATA Led locate
Disabled
Enabled
If enabled LED/SGPIO hardware is attached
www.kontron.com
// 177
COMe-bBD6 User Guide Rev. 1.4
6.5.3.50 USB Configuration
Figure 93: USB Configuration Menu Screen
Table 111: USB Configuration Features List
Feature
Options
Description
USB Precondition
Enabled
Disabled
Precondition work on USB host controller and root ports for faster enumeration.
xHCI Mode
Smart Auto
…
Disabled
Manual
Mode of operation of xHCI controller.
Trunk Clock Gating (BTCG)
Enabled
Disabled
Enable/Disable BTCG.
EHCI1
Disabled
Enabled
Control the USB EHCI (USB 2.0) functions. One EHCI controller must always be enabled.
EHCI2
Disabled
Enabled
Control the USB EHCI (USB 2.0) functions. One EHCI controller must always be enabled.
USB Per-Port Control
Disabled
Enabled
Control each of the USB ports (0~13) disabling.
XHCI Idle L1
Enabled
Disabled
Enabled XHCI Idle L1. Disabled to workaround USB3 hot plug will fall after 1 hot plug
removal. Please put the system to G3 for the new settings to take effect.
www.kontron.com
// 178
COMe-bBD6 User Guide Rev. 1.4
6.5.3.51 Security Configuration
Figure 94: Security Configuration Menu Screen
Table 112: Security Configuration Features List
Feature
Options
Description
GPIO Lockdown
Disabled
Enabled
Enable/Disable the PCH GPIO Lockdown feature.
RTC Lock
Disabled
Enabled
Enable will lock bytes 38h-3Fh in the lower/upper 128-byte bank o fRTC RAM
BIOS Lock
Disabled
Enabled
Enable/Disable the PCH BIOS Lock Enable feature.
Host Flash Lock-Down
Disabled
Enabled
Enable/Disable Host Flash Lock-Down
Gbe Flash Lock-Down
Disabled
Enabled
Enable/Disable Gbe Flash Lock-Down
www.kontron.com
// 179
COMe-bBD6 User Guide Rev. 1.4
6.5.3.52 Azalia Configuration
Figure 95: Azalia Configuration Menu Screen
Table 113: Azalia Configuration Features List
Feature
Options
Description
Azalia
Disabled
Enabled
Auto
Control Detection of the Azalia device. Auto = Azalia will be enabled if present, disabled
otherwise. Disabled = Azalia will be unconditionally disabled, regardless of presence.
Azalia Docking Support Enable
Disabled
Enabled
Enable/Disable Azalia Docking Support of Audio Controller.
Azalia PME Enable
Disabled
Enabled
Enable/Disable PME for Azalia.
www.kontron.com
// 180
COMe-bBD6 User Guide Rev. 1.4
6.5.3.53 Platform Thermal Configuration
Figure 96: Platform Thermal Configuration Menu Screen
Table 114: Platform Thermal Configuration Features List
Feature
Options
Description
PCH Thermal Device
Disabled
Enabled
Auto
Enable/Disable PCH Thermal Device(D31:F6)
Alert Enable Lock
Disabled
Enabled
Lock all Alert Enable settings
Enable Thermal Lock-Down
Disabled
Enabled
Enable will execute thermal programming, use disable as WA for PCHHOT
www.kontron.com
// 181
COMe-bBD6 User Guide Rev. 1.4
6.5.3.54 Miscellaneous Configuration
Figure 97: Miscellaneous Configuration Menu Screen
Table 115: Miscellaneous Configuration Features List
Feature
Options
Description
Fan PWM Offset
0
Specify fan speed offset
PCIe Max Read Request Size
128B
256B
…
4096B
Set Max Rest Request Size
PCIe LAtency Tolerance Reporting
Disable
Enable
Enable or Disable or Auto the LTR support
PCI Minimum Secondary Bus
Number
1
Specify the PCI minimum secondary bus number in system
PCIe Extended Tag Enable
Auto
Disable
Enable
Enable or Disable Extended Tag Enable Field Support
PCIe AtomicOp Request Support
Disable
Enable
Enable or disable AtomicOp Request Support
Breakpoint Type
None
After MRC
After QPIRC
…
Ready for IBIST
Halt at specified points in BIOS
www.kontron.com
// 182
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Serial Debug Message Level
Disable
Minimum
Normal
Maximum
Disable = no serial debug message, Minimum = high level debug messages, Normal =
general debug messages
Trace Messages
Disabled
Enabled
Enabled for
registry writes
only.
Enables display of every IO access
Training Messages
Disabled
Enabled
Enabled = set to disable the training results. Training results also get displayed if debug
messages is set to Maximum.
RC Promote Warnings
Disabled
Enabled
If enabled RC warnings are promoted to errors (except MRC warnings)
RC Promote MRC Warnings
Disabled
Enabled
If enabled MRC warnings are promoted to errors
Active Video
Onboard Device Select active Video type
Offboard Device
www.kontron.com
// 183
COMe-bBD6 User Guide Rev. 1.4
6.5.3.55 Server ME Debug Configuration
Figure 98: Server ME Debug Configuration Menu Screen
www.kontron.com
// 184
COMe-bBD6 User Guide Rev. 1.4
6.5.3.56 Server ME General Configuration
Figure 99: Server ME General Configuration Menu Screen
Table 116: Server ME General Configuration Features List
Feature
Options
Description
ME Initialization Complete Timeout
2
This option defines how long BIOS waits for ME to initialize.
Custom HPET timer for SPS HECI
wai
1
Custom HPET timer for SPS HECI Waiting
www.kontron.com
// 185
COMe-bBD6 User Guide Rev. 1.4
6.5.3.57 Override ICC Clock Enables
Figure 100: Override ICC Clock Enables Menu Screen
Table 117: Override ICC Clock Enables Features List
Feature
Options
Description
Override ICC Clock Enables
Disabled
Enabled
This option allows customization of clock enables.
FLEX0 Output (bit 0)
Disabled
Enabled
FLEX0 Output (bit 1)
Disabled
Enabled
FLEX0 Output (bit 2)
Disabled
Enabled
FLEX0 Output (bit 3)
Disabled
Enabled
PCICL0 Output (bit 7)
Disabled
Enabled
PCICL1 Output (bit 8)
Disabled
Enabled
PCICL2 Output (bit 9)
Disabled
Enabled
www.kontron.com
// 186
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
PCICL3 Output (bit 10)
Disabled
Enabled
PCICL4 Output (bit 11)
Disabled
Enabled
SRC0 Output (bit 16)
Disabled
Enabled
SRC1 Output (bit 17)
Disabled
Enabled
SRC2 Output (bit 18)
Disabled
Enabled
SRC3 Output (bit 19)
Disabled
Enabled
SRC4 Output (bit 20)
Disabled
Enabled
SRC5 Output (bit 21)
Disabled
Enabled
SRC6 Output (bit 22)
Disabled
Enabled
SRC7 Output (bit 23)
Disabled
Enabled
ITPXDP Output (bit 24)
Disabled
Enabled
PEG_A Output (bit 26)
Disabled
Enabled
PEG_B Output (bit 27)
Disabled
Enabled
DP Output (bit 29)
Disabled
Enabled
DPNS Output (bit 30)
Disabled
Enabled
www.kontron.com
Description
// 187
COMe-bBD6 User Guide Rev. 1.4
6.5.3.58 Override ICC Spread Spectrum Configuration
Figure 101: Override ICC Spectrum Configuration Menu Screen
Table 118: Override ICC Spectrum Configuration Features List
Feature
Options
Description
Override ICC Spread Spectrum
Confi
Override
Auto
Set non-default ICC spread spectrum configuration.
SSC0 mode
…
SSC7 mode
Down
Center
Disable
DoNotChange
Auto
Select spread spectrum mode.
www.kontron.com
// 188
COMe-bBD6 User Guide Rev. 1.4
6.5.3.59 NM Configuration
Figure 102: NM Configuration Menu Screen
Table 119: NM Configuration Features List
Feature
Options
Description
Boot Mode Override
Disabled
Enabled
Enables overriding the boot mode requested in NMFS register.
Boot Mode
Performance Optimized
Power Optimized
The boot mode to use instead of the mode requested in NMFS register.
Cores Disable Override
Disabled
Enabled
Enables overriding the value of the number of cores to disable
requested in NMFS register.
Cores to Disable
0
The number of cores to disable instead of the number requested in
NMFS register.
Power Measurement Override
Disabled
Enabled
Override power measurement support status reported to ME
Power Measurement
Disabled
Enabled
Override power measurement support status reported to ME
Hardware Change Override
Disabled
Enabled
Override hardware change detection status reported to ME
Hardware Changed
no
yes
Override hardware change detection status reported to ME
www.kontron.com
// 189
COMe-bBD6 User Guide Rev. 1.4
6.5.3.60 Server ME Configuration
Figure 103: Server ME Configuration Menu Screen
Table 120: Server ME Configuration Features List
Feature
Options
Description
Altitude
80000000
The altitude of the platform location above the see level, expressed in meters. The hex
number is decoded as 2’s complement signed integer. Provide the 80000000 value if the
altitude is unknown.
MCTP Bus Owner
0
MTCP bus owner location on PCIe: [15:8] bus, [7:3] device, [2:0] function. If all zeros
sending bus owner is disabled.
www.kontron.com
// 190
COMe-bBD6 User Guide Rev. 1.4
6.5.3.61 Runtime Error Logging
Figure 104: Runtime Error Logging Menu Screen
Table 121: Runtime Error Logging Features List
Feature
Options
Description
System Errors
Disable
Enable
Auto
System Error enabling and logging setup option.
S/W Error Injection Support
Disable
Enable
When Enabled S/W Error Injection is supported by unlocking MSR 0x790
Clear McBankErrors
Disable
Enable
Enables or Disables clearing MCBank erros on warm reset.
System Poison
Disable
Enable
Enable/Disable Core, Uncore and IIO Poison
IIO Error Enable
no
yes
PCH Error Enable
no
yes
Enable Cloaking
Enable
Disable
www.kontron.com
Enable / Disable Corrected Error Cloaking
// 191
COMe-bBD6 User Guide Rev. 1.4
6.5.3.62 Whea Settings
Figure 105: Whea Settings Menu Screen
Table 122: Whea Settings Features List
Feature
Options
Description
Whea Support
Disable
Enable
Enable or disable the WHEA support
www.kontron.com
// 192
COMe-bBD6 User Guide Rev. 1.4
6.5.3.63 Memory Error Enabling
Figure 106: Memory Error Enabling Menu Screen
Table 123: Memory Error Enabling Features List
Feature
Options
Description
Memory corrected Error enbaling
Disable
Enable
Enable/ Disable Memory corrected Errors
Spare interrupt
SMI
CMCI
Error Pin
Select SMI/CMCI/ErrPin for spare interrupt
www.kontron.com
// 193
COMe-bBD6 User Guide Rev. 1.4
6.5.3.64 IIO Error Enable
Figure 107: IIO Error Enable Menu Screen
Table 124: IIO Error Enable Features List
Feature
Options
Description
Error pin Programming for IIO
None
SMI
Error pin Programming
DMI Errors
Disable
Enable
Enable/Disable DMI errors
Vtd Errors
Disable
Enable
Enable/Disable Vtd errors
Misc Errors
Disable
Enable
Enable/Disable Miscellaneous errors
IIO core Errors
Disable
Enable
Enable/Disable IIO core errors
DMA Errors
Disable
Enable
Enable/Disable DMA errors
Coherency Interface Errors
Disable
Enable
Enable/Disable Coherency Interface errors
www.kontron.com
// 194
COMe-bBD6 User Guide Rev. 1.4
6.5.3.65 IIO Coherency Interface Error Enable
Figure 108: IIO Coherency Interface Error Enable Menu Screen
Table 125: IIO Coherency Interface Error Enable Features List
Feature
Options
Description
IIO IRP0 protocol parity error
Disable
Enable
Enable or disable Coherent Interface protocol IIO parity error reporting
IIO IRP0 protocol qt overflow unde
Disable
Enable
Enable or disable IIO Coherent Interface protocol queue table overflow or underflow error
reporting
IIO IRP0 protocol rcvd unexprsp
Disable
Enable
Enable or disable IIO Coherent Interface protocol layer received unexpected response or
completion error reporting
IIO IRP0 csr acc 32b unaligned
Disable
Enable
Enable or disable IIO Coherent Interface CSR access Crossing 32-bit Boundary error
reporting
IIO IRP0 wrcache uncecc error
Disable
Enable
Enable or disable IIO Coherent Interface Write Cache Un-correctable ECC error reporting
IIO IRP0 protocol rcvd poison erro
Disable
Enable
Enable or disable IIO Coherent Interface Protocol Layer Received Poisoned Packet error
reporting
IO IRP0 wrcache correcc error
Disable
Enable
Enable or disable IIO Coherent Interface Write Cache Correctable ECC error reporting
www.kontron.com
// 195
COMe-bBD6 User Guide Rev. 1.4
6.5.3.66 PCI/PCI Error Enabling
Figure 109: PCI/PCI Error Enabling Menu Screen
Table 126: PCI/PCI Error Enabling Features List
Feature
Options
PCI-Ex Error Enable
no
yes
Corrected Error Enable
Disabled
Enabled
Enable/Disable PCIe Correctable errors.
Uncorrected Error Enable
Disabled
Enabled
Enable/Disable PCIe Uncorrectable errors.
Fatal Error Enable
Disabled
Enabled
Enable/Disable PCIe Fatal errors.
PCIe Correctable error threshold
0
PCIe CE threshold(1-255), 0-No threshold.
Enable SERR propagation
no
yes
Enable PERR propagation
no
yes
Pcie Extended errors
Disabled
Enabled
www.kontron.com
Description
Enable/Disable –IIO Pcie Rootport errors
// 196
COMe-bBD6 User Guide Rev. 1.4
6.5.3.67 Reserved Memory
Figure 110: Reserved Memory Menu Screen
Table 127: Reserved Memory Features List
Feature
Options
Description
Reserve Memory Range
Disabled
Enabled
Sets aside an empty memory page that is hidden from the OS
Start Address
100000
Address that reserved memory page starts at
Reserve TAGEC Memory
Disable
Enable
Reserve 16M for TAGEC
www.kontron.com
// 197
COMe-bBD6 User Guide Rev. 1.4
6.5.4 Security
Figure 111: Security Menu Screen
Table 128: Security Features List
Feature
Options
Description
Administrator Password
Set administrator Password
User Password
Set user Password
www.kontron.com
// 198
COMe-bBD6 User Guide Rev. 1.4
6.5.4.1 Secure Boot menu
Figure 112: Secure Boot menu Menu Screen
Table 129: Secure Boot menu Features List
Feature
Options
Description
Secure Boot
Disabled
Enabled
Secure Boot can be enabled if 1.System running in User mode with enrolled Platform Key(PK) 2.CSM
function is disabled
Secure Boot Mode
Standard
Custom
Secure Boot mode selector. ‘Custom’ Mode enables users to change Image Execution policy and
manage Secure Boot Keys
www.kontron.com
// 199
COMe-bBD6 User Guide Rev. 1.4
6.5.4.2 Key Management
Figure 113: Key Management Menu Screen
Table 130: Key Management Features List
Feature
Options
Description
Provision Factory Default keys
Disable
Enable
Install factory default Secure Boot keys when System is in Setup Mode
Enroll all Factory Default Keys
Force System to User Mode – install all Factory Default keys(PK,KEK,db,dbt,dbx). Change
takes effect after reboot
Platform Key(PK)
Enroll Factory Defaults or load the keys from a file with:
1.Public Key Certificate in:
a)EFI_SIGNATURE_LIST
b)EFI_CERT_X509 (DER encoded)
c)EFI_CERT_RSA2048 (bin)
d)EFI_CERT_SHA256 (bin)
2.Authenticated UEFI Variable
Key Exchange keys
Authorized Signatures
Forbidden Signatures
Key source:Default,Custom,Mixed (*) modified from Setup menu
Authorized TimeStamps
www.kontron.com
// 200
COMe-bBD6 User Guide Rev. 1.4
6.5.5 Boot
Figure 114: Boot Menu Screen
Table 131: Boot Features List
Feature
Options
Description
Setup Prompt Timeout
1
Number of seconds to wait for setup activation key. 65535(0xFFFF) means
indefinite waiting.
Bootup NumLock State
On
Off
Select the keyboard NumLock state
Quiet Boot
Disabled
Enabled
Enables or disables Quiet Boot option
Boot Option #1
IBA GE Slot 0200 v1570
IBA XE Slot 0400 v2353
IBA XE Slot 0401 v2353
UEFI: Built-in EFI Shell
Disabled
Sets the system boot order
Boot Option #2
IBA GE Slot 0200 v1570
IBA XE Slot 0400 v2353
IBA XE Slot 0401 v2353
UEFI: Built-in EFI Shell
Disabled
Sets the system boot order
www.kontron.com
// 201
COMe-bBD6 User Guide Rev. 1.4
Feature
Options
Description
Boot Option #3
IBA GE Slot 0200 v1570
IBA XE Slot 0400 v2353
IBA XE Slot 0401 v2353
UEFI: Built-in EFI Shell
Disabled
Sets the system boot order
Boot Option #4
IBA GE Slot 0200 v1570
IBA XE Slot 0400 v2353
IBA XE Slot 0401 v2353
UEFI: Built-in EFI Shell
Disabled
Sets the system boot order
www.kontron.com
// 202
COMe-bBD6 User Guide Rev. 1.4
6.5.6 Event Logs
Figure 115: Event Logs Menu Screen
www.kontron.com
// 203
COMe-bBD6 User Guide Rev. 1.4
6.5.6.1 Change Smbios Event Log Settings
Figure 116: Change Smbios Event Log Settings Menu Screen
Table 132: Change Smbios Event Log Settings Features List
Feature
Options
Description
Smbios Event Log
Enabled
Change this to enable or disable all features of Smbios Event Logging during boot.
Erase Event Log
No
Yes, Next reset
Yes, Every reset
Choose options for erasing Smbios Event Log. Erasing is done prior to any logging
activation during reset.
When Log is Full
Do Nothing
Erase Immediately
Choose options for reactions to a full Smbios Event Log.
Log System Boot Event
Enable
Disable
Choose option to enable/disable logging of System boot event
MECI
1
Multiple Event Count Increment: The number of occurrences of a duplicate event that
must pass before the multiple-event counter of log entry is updated. The value ranges
from 1 to 255.
METW
60
Multiple Event Time Window: The number of minutes which must pass between
duplicate log entries which utilize a multiple-event counter. The value ranges from 0 to
99 minutes.
Log OEM Codes
Enable
Disable
Enable or disable the logging of EFI Status Codes as OEM Codes (if not already
converted to legacy).
Convert OEM Codes
Enable
Disable
Enable or disable the converting of EFI Status Codes to Standard Smbios Types (Not all
may be translated).
www.kontron.com
// 204
COMe-bBD6 User Guide Rev. 1.4
6.5.6.2 View Smbios Event Log
Figure 117: View Smbios Event Log Menu Screen
www.kontron.com
// 205
COMe-bBD6 User Guide Rev. 1.4
6.5.7 Save & Exit
Figure 118: Save & Exit Menu Screen
Table 133: Save & Exit Features List
Feature
Options
Description
Save Changes and Exit
-
Exit system setup after saving the changes.
Discard Changes and Exit
-
Exit system setup without saving any changes.
Save Changes and Reset
-
Reset system after saving the changes.
Discard Changes and Reset
-
Reset system without saving any changes.
Save Changes
-
Save Changes done so far to any of the setup options.
Discard Changes
-
Discard Changes done so far to any of the setup options.
Restore Defaults
-
Restore/Load Default values for all the setup options.
Save as User Defaults
-
Save the changes done so far as User Defaults.
Restore User Defaults
-
Restore the User Defaults to all the setup options.
Boot Override
List of all boot options
Boot directly from selected device
www.kontron.com
// 206
Appendix A: PICMG COME.0 Signal Terminology
COMe-bBD6 User Guide Rev. 1.4
Table 134: PICMG COME.0 Signal Terminology
Term
Definition
AC ‘97
Audio CODEC (Coder-Decoder)
ACPI
Advanced Configuration Power Interface – standard to implement power saving modes in PCAT systems
Basic Module
COM Express® 125mm x 95mm Module form factor.
BIOS
Basic Input Output System – firmware in PC-AT system that is used to initialize system components before handing control
over to the operating system.
CAN
Controller-area network (CAN or CAN-bus) is a vehicle bus standard designed to allow microcontrollers to communicate with
each other within a vehicle without a host computer.
Carrier Board
An application specific circuit board that accepts a COM Express® Module.
CCTV
Closed Circuit Television
CVBS
Composite Video Baseband Signal
Compact Module
COM Express® 95x95 Module form factor
DDC
Display Data Control – VESA (Video Electronics Standards Association) standard to allow identification of the capabilities of a
VGA monitor
DDI
Digital Display Interface – containing DisplayPort, HDMI/DVI and SDVO
DIMM
Dual In-line Memory Module
DisplayPort
DisplayPort is a digital display interface standard put forth by the Video Electronics Standards Association (VESA). It defines a
new license free, royalty free, digital audio/video interconnect, intended to be used primarily between a computer and its
display monitor.
DRAM
Dynamic Random Access Memory
DVI
Digital Visual Interface - a Digital Display Working Group (DDWG) standard that defines a standard video interface supporting
both digital and analog video signals. The digital signals use TMDS.
EAPI
Embedded Application Programming Interface Software interface for COM Express® specific industrial functions

System information

Watchdog timer

I2C Bus

Flat Panel brightness control

User storage area

GPIO
EEPROM
Electrically Erasable Programmable Read-Only Memory
Embedded
DisplayPort
Embedded Display Port (eDP) is a digital display interface standard produced by the Video Electronics Standards Association
(VESA) for digital interconnect of Audio and Video.
Extended Module
COM Express® 155mm x 110mm Module form factor.
FR4
A type of fiber-glass laminate commonly used for printed circuit boards.
Gb
Gigabit
GBE
Gigabit Ethernet
GPI
General Purpose Input
GPIO
General Purpose Input Output
www.kontron.com
// 207
COMe-bBD6 User Guide Rev. 1.4
Term
Definition
GPO
General Purpose Output
HDA
Intel High Definition Audio (HD Audio) refers to the specification released by Intel in 2004 for delivering high definition audio
that is capable of playing back more channels at higher quality than AC97.
HDMI
High Definition Multimedia Interface
I2C
Inter Integrated Circuit – 2 wire (clock and data) signaling scheme allowing communication between integrated circuits,
primarily used to read and load register values.
IDE
Integrated Device Electronics – parallel interface for hard disk drives – also known as PATA
Legacy Device
Relics from the PC-AT computer that are not in use in contemporary PC systems: primarily the ISA bus, UART-based serial
ports, parallel printer ports, PS-2 keyboards, and mice. Definitions vary as to what constitutes a legacy device. Some
definitions include IDE as a legacy device.
LAN
Local Area Network
LPC
Low Pin-Count Interface: a low speed interface used for peripheral circuits such as Super I/O controllers, which typically
combine legacy-device support into a single IC.
LS
Least Significant
LVDS
Low Voltage Differential Signaling – widely used as a physical interface for TFT flat panels. LVDS can be used for many highspeed signaling applications. In this document, it refers only to TFT flat-panel applications.
ME
Management Engine
Mini Module
COM Express® 84x55mm Module form factor
MS
Most Significant
NA
Not Available
NC
No Connect
NTSC
National Television Standards Committee – video broadcast standard used in North America
OEM
Original Equipment Manufacturer
PAL
Phase Alternating Line – video broadcast standard used in many European countries.
PATA
Parallel AT Attachment – parallel interface standard for hard-disk drives – also known as IDE, AT Attachment, and as ATA
PC-AT
“Personal Computer – Advanced Technology” – an IBM trademark term used to refer to Intel x86 based personal computers
in the 1990s
PCB
Printed Circuit Board
PCI
Peripheral Component Interface
PCI Express
PCIE
Peripheral Component Interface Express – next-generation high speed Serialized I/O bus
PEG
PCI Express Graphics
PHY
Ethernet controller physical layer device
Pin-out Type
A reference to one of seven COM Express® definitions for the signals that appear on the COM Express® Module connector
pins.
PS2
PS2 Keyboard
PS2 Mouse
“Personal System 2” - an IBM trademark term used to refer to Intel x86 based personal computers in the 1990s. The term
survives as a reference to the style of mouse and keyboard interface that were introduced with the PS2 system.
Ra
Roughness Average – a measure of surface roughness, expressed in units of length.
ROM
Read Only Memory – a legacy term – often the device referred to as a ROM can actually be written to, in a special mode.
Such writable ROMs are sometimes called Flash ROMs. BIOS is stored in ROM or Flash ROM.
RTC
Real Time Clock – battery backed circuit in PC-AT systems that keeps system time and date as well as certain system setup
parameters
www.kontron.com
// 208
COMe-bBD6 User Guide Rev. 1.4
Term
Definition
SAS
Serial Attached SCSI – high speed serial version of SCSI
SCSI
Small Computer System Interface – an interface standard for high end disk drives and other computer peripherals
SPD
Serial Presence Detect – refers to serial EEPROM on DRAMs that has DRAM Module configuration information
SPI
Serial Peripheral Interface
SO-DIMM
Small Outline Dual In-line Memory Module
S0, S1, S2, S3, S4,
S5
System states describing the power and activity level
S0
Full power, all devices powered
S1
S2
S3
Suspend to RAM System context stored in RAM; RAM is in standby
S4
Suspend to Disk System context stored on disk
S5
Soft Off Main power rail off, only standby power rail present
SATA
Serial AT Attachment: serial-interface standard for hard disks
SDVO
Serialized Digital Video Output – Intel defined format for digital video output that can be used with Carrier Board conversion
ICs to create parallel, TMDS, and LVDS flat-panel formats as well as NTSC and PAL TV outputs
SM Bus
System Management Bus
Super I/O
An integrated circuit, typically interfaced via the LPC bus that provides legacy PC I/O functions including PS2 keyboard and
mouse ports, serial and parallel port(s) and a floppy interface.
TFT
Thin Film Transistor – refers to technology used in active matrix flat-panel displays, in which there is one thin film transistor
per display pixel.
TMDS
Transition Minimized Differential Signaling - a digital signaling protocol between the graphics subsystem and display. TMDS is
used for the DVI digital signals.
TPM
Trusted Platform Module, chip to enhance the security features of a computer system.
USB
Universal Serial Bus
VGA
Video Graphics Adapter – PC-AT graphics adapter standard defined by IBM.
WDT
Watch Dog Timer.
XAUI
10 Gigabit / sec Attachment Unit Interface.
www.kontron.com
// 209
COMe-bBD6 User Guide Rev. 1.4
About Kontron
Kontron, a global leader in embedded computing technology and trusted advisor in IoT, works closely
with its customers, allowing them to focus on their core competencies by offering a complete and
integrated portfolio of hardware, software and services designed to help them make the most of their
applications.
With a significant percentage of employees in research and development, Kontron creates many of
the standards that drive the world’s embedded computing platforms; bringing to life numerous
technologies and applications that touch millions of lives. The result is an accelerated time-to-market,
reduced total-cost-of-ownership, product longevity and the best possible overall application with
leading-edge, highest reliability embedded technology
Kontron is a listed company. Its shares are traded in the Prime Standard segment of the Frankfurt
Stock Exchange and on other exchanges under the symbol “KBC”. For more
information, please visit: www.kontron.com

CORPORATE OFFICES
EUROPE, MIDDLE EAST
& AFRICA
NORTH AMERICA
ASIA PACIFIC
Lise-Meitner-Str. 3-5
86156 Augsburg
Germany
Tel.: + 49 821 4086-0
Fax: + 49 821 4086-111
info@kontron.com
14118 Stowe Drive
Poway, CA 92064-7147
USA
Tel.: + 1 888 294 4558
Fax: + 1 858 677 0898
info@us.kontron.com
1~2F, 10 Building, No. 8 Liangshuihe 2nd Street,
Economical & Technological Development Zone,
Beijing, 100176, P.R. China
Tel.: + 86 10 63751188
Fax: + 86 10 83682438
info@kontron.cn
www.kontron.com
// 210