PRODUCT
GUIDE
ELECTRIC • GAS • OIL • TANKLESS
Visit
online!
Visit www.johnwoodwaterheaters.com to access
valuable information concerning John Wood®
products and services such as:
• Parts Catalogue
• Warranty Validation
• ENERGY STAR® qualified products
• Information on products, including specifications
and installation manuals
• Frequently Asked Questions
• Resource center for contractors which includes product images
Table of Contents
John Wood® Water Heaters
1
STORAGE-TYPE PRODUCTS
John Wood® Safety Systems
5
ProLine® XE Atmospheric Vent
6
ProLine® & ProLine® Master Atmospheric Vent
8
ProLine® XE Power Vent
10
ProLine® XE Power Direct Vent
12
ProLine® Direct Vent
14
Envirosense® Power Direct Vent
16
Envirosense® Power Vent
18
Polaris™20
ProLine® & ProLine® Master Electric
22
Space Saver® Electric
24
Oil Fired & Oil Burners
26
Storage Booster Tanks
28
Flow THRU®29
TANKLESS PRODUCTS
John Wood® powered by Takagi Tankless (Condensing)
34
John Wood® powered by Takagi Tankless (Non-Condensing)
36
John Wood® powered by Takagi Tankless (Concentric Vent)
38
Table of Contents
APPENDICES
Ohm’s Law
42
Reference Guide for Water Heating
44
Exclusive Designs, Service & Support
49
John Wood® maintains a policy of ongoing product improvement. This may result in
modification of features and/or specifications without notice.
RESIDENTIAL WATER HEATERS
WITH
COMMERCIALGRADE
COMPONENTS
DON’T WASTE
YOUR ENERGY
WITH ANY OTHER POWER VENT
John Wood has the
most complete
line-up of Power
Vent water heaters
in their class and
exceed ENERGY STAR®
qualifications with up
an to
an amazing 0.70 EF.
Learn more on
Pages 10 and 11
in this catalogue.
Storage-Type
John Wood® Safety Systems
Flammable Vapour Ignition Resistant (FVIR) technology you
can trust.
John Wood residential water heaters use one of three unique Flammable Vapour
Ignition Resistant (FVIR) Safety Systems that reduce the risk of accidental fires
caused by the ignition of flammable vapours from products such as gasoline,
paint thinner and solvents: the Flame Guard® and Flame SafeTM Safety Systems
and the Power Vent Safety System.
Flame Guard® Safety System Used on
John Wood Atmospheric Vent Water Heaters
The Flame Guard® Safety System is a recognized and proven technology used
on John Wood Atmospheric Vent water heaters. The award winning Flame
Guard® Safety System protects the consumer by trapping burning vapours
within the water heater combustion chamber through the patented “Flame-Trap.” As
long as the vapours are present and within the flammability range, they will continue to
burn safely until they “burn themselves out.”
Flame SafeTM Safety System Used
on John Wood Direct Vent Water Heaters
Flame SafeTM technology - designed to protect the consumer against the
ignition of flammable vapours.
Power Vent Safety System
The Safety System used on John Wood Power Vent water heaters features a flammable
vapour sensor and air intake snorkel. This system not only shuts down the unit when
flammable vapours are detected in the area of the water heater but elevates the air
intake so that flammable vapours do not enter the combustion chamber and ignite
before the sensor shuts down the water heater.
5
ProLine® XE Atmospheric Vent
ENERGY STAR® qualified
Features
• Flue damper for increased energy efficiency
and performance
• 24 volt gas valve offers: Diagnostic capabilities,
monitors damper to ensure proper operation and
safety, spark ignition eliminates the need for a
standing pilot
• Robust 1/4” pilot tubing
• Durable brass drain valve
• Turbulator dip tube reduces sediment build-up at
bottom of the tank
• Glass-lined tank to prolong tank life and prevent
corrosion
• Plugs into a standard 110/120V outlet (10 ft. power
cord included)
• Combustion chamber is easy to access
• Conveniently located T&P and drain valve
for ease of installation and serviceability
• Top mounted heavy duty anode rod for added tank
protection
PERFORMANCE
Model
Series
Recovery Rate
Maximum
at 90°F
First Hour
Warranty
Capacity Input* Certified
Temperature Rating Energy Tank/Parts
Altitude
Rise
Factor
USG (L)
BTU/h
FT (M)
GPH (LPH)
GPH (LPH)
Years
41 (155)
67 (254)
0.67
6/6
41 (155)
67 (254)
0.67
6/6
41 (155)
81 (307)
0.67
6/6
41 (155)
81 (307)
0.67
6/6
NATURAL GAS
10,100
(3,078)
10,100
JW640T40N-AV-ES2 100/101 40 (151) 40,000
(3,078)
10,100
JW650S40N-AV-ES2 100** 50 (189) 40,000
(3,078)
10,100
JW650T40N-AV-ES2 100/101 50 (189) 40,000
(3,078)
JW640S40N-AV-ES2 100/101 40 (151) 40,000
Propane models sub N with P. Natural gas models are series 100. Propane models are series 101.
*Propane Gas – 36,000 for the 40 gallon models and 37,000 for the 50 gallon tall models.
**50 USG Short model is not available for Propane.
All models comply with national energy efficiency regulations.
6
ProLine® XE Atmospheric Vent
ProLine® XE Atmospheric Vent
7
54 (137)
64 1/4 (163)
55 3/4 (142)
63 1/2 (161)
JW640T40N-AV-ES2
JW650S40N-AV-ES2
JW650T40N-AV-ES2
57 1/4 (145)
49 1/2 (126)
58 1/4 (148)
47 3/4 (121)
B
IN (CM)
A
IN (CM)
JW640S40N-AV-ES2
Model
Height to Top
of Tank
Installation
Height
DIMENSIONS & SHIPPING WEIGHT
22 (56)
24 (61)
20 (51)
22 (56)
C
IN (CM)
13 (33)
13 (33)
13 (33)
13 (33)
D
IN (CM)
8 (20)
8 (20)
8 (20)
8 (20)
E
IN (CM)
50 1/4 (128)
42 1/2 (108)
51 3/4 (131)
41 (104)
F
IN (CM)
Tank
Height to Gas Hot Connection to
Height to T&P
Diameter
Inlet
Cold Connection
3 or 4
3 or 4
3 or 4
3 or 4
IN
Drafthood
Connector
Diameter
167 (76)
183 (83)
152 (51)
149 (68)
LB (KG)
Shipping
Weight
E
C
F
B
A
COLD
COLD
CONNECTION
CONNECTION
Maximum Hydrostatic
Working
Pressure:
150 PSI.
Maximum
Hydrostatic
Working
Pressure:
150 PSI
D
1/2” GAS
1/2"
GAS
CONNECTION
CONNECTION
T&PVALVE
VALVE
T&P
HOT
HOT
CONNECTION
CONNECTION
ANODEROD
ROD
ANODE
ProLine® & ProLine® Master Atmospheric Vent
Proven technology and exceptional reliability
Features
• Turbulator dip tube reduces sediment build-up at the
bottom of the tank
• Thermopile design provides robust pilot to withstand
down drafts and environmental conditions
• Gas valve offers easy temperature adjustments and
has LED indicator light for operation, diagnostic and
troubleshooting assistance
• Robust 1/4” pilot tubing
• The Flame Guard® Safety System protects the
homeowner by trapping burning vapours within the
water heater’s easy to access combustion chamber
• Conveniently located T&P and drain valve for ease of
installation and serviceability
• Piezoelectric ignitor allows for lighting of the pilot without
matches
• Top mounted heavy duty anode rod for added tank
protection
• 2 or 4 year tank warranty extension kits are available for 6
year models
PERFORMANCE
Model
Series
Maximum Recovery Rate
Warranty
First Hour
at 90°F
Capacity Input† Certified Temperature
Rating Energy Tank/Parts
Altitude
Rise
Factor
USG (L) BTU/h FT (M) GPH (LPH) GPH (LPH)
Years
NATURAL GAS
AV30N
400/401 30 (114) 35,500
AV40N
400/401 40 (151) 40,000
AV40TN
400/401 40 (151) 40,000
AV50N
400/401 50 (189) 40,000
AV50TN
400/401 50 (189) 40,000
AV60N
400/401 60 (227) 52,200
AV75N*
400/401 75 (284) 75,100
10,100
(3,078)
10,100
(3,078)
10,100
(3,078)
10,100
(3,078)
10,100
(3,078)
10,100
(3,078)
7,700
(2,347)
36 (136)
60 (227)
0.64
6/6
41 (155)
67 (254)
0.62
6/6
42 (159)
70 (265)
0.62
6/6
43 (163)
93 (352)
0.61
6/6
42 (159)
88 (333)
0.62
6/6
54 (204)
104 (344)
0.59
6/6
80 (303)
N/A
N/A
6/6
41 (155)
67 (254)
0.62
8/8
43 (163)
93 (352)
0.61
8/8
NATURAL GAS
AV40NM
AV50NM
10,100
(3,078)
10,100
400/401 50 (189) 40,000
(3,078)
400/401 40 (151) 40,000
Propane models sub N with P. Natural gas models are series 400. Propane models are series 401.
* Model has side connections
† Propane Gas – 36,000 for the 50 gallon short, 37,000 for the 50 gallon tall, & 36,000 for 40 gallon models and
32,000 input for 30 gallon models. All models comply with national energy efficiency regulations.
8
ProLine® & ProLine® Master Atmospheric Vent
ProLine® & ProLine® Master Atmospheric Vent
9
50 (127)
51 1/2 (131)
61 3/4 (157)
53 1/4 (135)
61 (155)
62 3/4 (159)
61 (155)
AV40N / AV40NM
AV40TN
AV50N / AV50NM
AV50TN
AV60N
AV75N
57 (145)
59 (150)
57 1/4 (145)
49 1/2 (126)
58 1/4 (148)
47 3/4 (121)
46 3/8 (118)
B
IN (CM)
A
IN (CM)
AV30N
Model
Height to Top
of Tank
Installation
Height
DIMENSIONS & SHIPPING WEIGHT
26 1/2 (67)
24 (61)
22 (56)
24 (61)
20 (51)
22 (56)
20 (51)
C
IN (CM)
14 3/4 (37)
13 (33)
13 (33)
13 (33)
13 (33)
13 (33)
13 1/2 (34)
D
IN (CM)
8 (20)
8 (20)
8 (20)
8 (20)
8 (20)
8 (20)
8 (20)
E
IN (CM)
50 1/4 (128)
51 1/2 (131)
50 1/4 (128)
4
4
4
3 or 4
3 or 4
51 ¾ (131)
42 1/2 (108)
3 or 4
3 or 4
IN
Drafthood
Connector
Diameter
41 (104)
40 (102)
F
IN (CM)
Tank
Height to Gas Hot Connection to
Height to T&P
Diameter
Inlet
Cold Connection
273 (124)
205 (93)
165 (75)
175 (79)
150 (68)
135 (61)
118 (53)
LB (KG)
Shipping
Weight
1/2” GAS
CONNECTION
T&P VALVE
HOT
CONNECTION
ANODE ROD
COLD
CONNECTION
ProLine® XE Power Vent
ENERGY STAR® qualified
Features
• Industry-leading energy efficient power vent, with
up to a 0.70 EF
• ENERGY STAR® qualified (except 60 and 75
• gallon models)
• State-of-the-art electronic gas control features
advanced self-diagnostic capability that makes
troubleshooting easy
• Ideal as a replacement water heater in a variety of
installation applications due to 3-position rotatable
blower
• Can be vented with 2”, 3” or 4” ULC S636 PVC, CPVC
or polypropylene pipe
• Vertical or horizontal venting configurations
• Convenient 3/4” side taps for combination
applications on 50 USG high-input and 75 USG
models
• 2 or 4 year tank warranty extension kits are
available for 6 year models
PERFORMANCE
Recovery
Warranty
Maximum
Rate at 90°F First Hour
Tank/
Certified
Temperature Rating Energy
Altitude
Factor Parts
Rise
Capacity
Input
USG (L)
BTU/h
FT (M)
GPH (LPH)
GPH (LPH)
PV40N
200/201 40 (151)
40,000
10,100 (3,078)
44 (167)
73 (276)
0.70
6/6
PV40TN
200/201 40 (151)
50,000
10,100 (3,078)
50 (189)
90 (341)
0.70
6/6
PV50N
200/201 50 (189)
40,000
10,100 (3,078)
44 (167)
90 (341)
0.70
6/6
PV50TN
200/201 50 (189)
50,000
10,100 (3,078)
50 (189)
96 (363)
0.70
6/6
PV50HIN
200/201 50 (189)
62,000
10,100 (3,078)
69 (261)
110 (416)
0.70
6/6
PV60N
200/201 60 (227)
42,000
10,100 (3,078)
46 (174)
106 (401)
0.70
6/6
PV75N
200/201 75 (284)
72,000
10,100 (3,078)
80 (303)
155 (587)
0.68
6/6
200/201 50 (189)
40,000
10,100 (3,078)
44 (167)
90 (341)
0.70
8/8
PV50HINM 200/201 50 (189)
62,000
10,100 (3,078)
69 (261)
110 (416)
0.70
8/8
Model
Series
Years
NATURAL GAS
NATURAL GAS
PV50NM
For propane models sub N with P. Natural gas models are series 200. Propane models are series 201.
All models comply with national energy efficiency regulations.
10
ProLine® XE Power Vent
ProLine® XE Power Vent
11
60 1/8 (153)
68 1/8 (173)
61 1/8 (155)
67 1/4 (171)
70 5/8 (179)
PV50N/PV50NM
PV50TN
PVHIN/PV50HINM*
PV60N
PV75N*
* Model has side connections
59 (150)
68 1/2 (174)
PV40TN
A
IN (CM)
PV40N
NATURAL GAS
Model
61 1/4 (156)
57 7/8 (147)
52 (132)
58 3/4 (149)
50 3/4 (129)
59 1/4 (150)
49 5/8 (126)
B
IN (CM)
Installation Height to Top
Height
of Tank
26 (66)
24 (61)
24 (61)
22 (56)
24 (61)
20 (51)
22 (56)
C
IN (CM)
Tank
Diameter
DIMENSIONS & SHIPPING WEIGHT
33 1/8 (84)
31 1/8 (79)
31 1/8 (79)
29 1/8 (74)
31 1/8 (79)
27 1/8 (69)
29 1/8 (74)
D
IN (CM)
Overall
Depth
11 (28)
11 (28)
11 (28)
11 (28)
11 (28)
11 (28)
11 (28)
E
IN (CM)
Height to
Drain Valve
13 1/4 (34)
13 1/4 (34)
13 1/4 (34)
13 1/4 (34)
13 1/4 (34)
13 1/4 (34)
13 1/4 (34)
F
IN (CM)
Height to
Gas Inlet
53 (135)
50 3/8 (128)
44 1/2 (113)
51 3/4 (131)
43 3/4 (111)
53 1/8 (135)
42 1/2 (108)
G
IN (CM)
Height
to T&P
53 (135)
N/A
44 1/2 (113)
N/A
N/A
N/A
N/A
G
IN (CM)
Height to
Upper Side
Connection
D
15 1/4 (39)
N/A
15 1/4 (39)
N/A
N/A
N/A
N/A
H
IN (CM)
Height to
Lower Side
Connection
277 (126)
216 (98)
212 (96)
192 (87)
198 (90)
176 (80)
174 (79)
LB (KG)
Shipping
Weight
D
C
E
F
H
G
B
A
C
ProLine® XE Power Direct Vent
ENERGY STAR® qualified
Features
• ENERGY STAR® qualified (except 75 gallon
model)
• Sealed combustion chamber design,
eliminating the need for a FV sensor
• Ultra-quiet blower
• Convenient 3/4” side water connections for
combination applications on high input 50 USG
and 75 USG units
• Can be vented with 2”, 3” or 4” ULC S636
PVC, CPVC or polypropylene pipe up to 180
equivalent feet (see installation manual for
full details)
• Zero clearance to combustibles
• Factory-installed heat trap nipples
• 2 or 4 year tank warranty extension kits are
available
PERFORMANCE
Model
Series
Maximum
Certified
Altitude
Capacity Input
Recovery Rate
Warranty
at 90°F First Hour
Temperature Rating Energy Tank/Parts
Factor
Rise
USG (L)
BTU/h
FT (M)
GPH (LPH) GPH (LPH)
Years
PDV40N
200/201 40 (151)
40,000
10,100 (3,078)
44 (167)
71 (269)
0.71
6/6
PDV50N
200/201 50 (189)
45,000
10,100 (3,078)
50 (189)
93 (352)
0.70
6/6
PDV50HIN
200/201 50 (189)
58,000
5,400 (1,646)
67 (254)
100 (379)
0.71
6/6
PDV75N
200/201 75 (284)
72,000
10,100 (3,078)
82 (310)
154 (583)
0.69
6/6
NATURAL GAS
For propane models sub N for P . Natural gas models are series 200. Propane models are series 201.
All models comply with national energy efficiency regulations.
12
ProLine® XE Power Direct Vent
ProLine® XE Power Direct Vent
13
67 1/2 (171)
68 7/8 (175)
70 5/8 (179)
PDV50HIN*
PDV75N*
*Model has side connections.
58 1/4 (148)
PDV50N
A
IN (CM)
PDV40N
NATURAL GAS
Model
60 1/2 (154)
60 1/4 (153)
58 7/8 (150)
49 1/2 (126)
B
IN (CM)
Installation Height to Top
Height
of Tank
26 (66)
22 (56)
22 (56)
22 (56)
C
IN (CM)
Tank
Diameter
DIMENSIONS & SHIPPING WEIGHT
33 7/8 (86)
29 7/8 (76)
29 7/8 (76)
29 7/8 (76)
D
IN (CM)
Overall
Depth
11 (28)
11 (28)
11 (28)
11 (28)
E
IN (CM)
Height to
Drain Valve
13 1/4 (34)
13 1/4 (34)
13 1/4 (34)
13 1/4 (34)
F
IN (CM)
Height to
Gas Inlet
53 (134)
52 3/4 (134)
51 3/4 (131)
42 3/8 (108)
G
IN (CM)
Height
to T&P
53 (134)
52 3/4 (134)
N/A
N/A
G
IN (CM)
15 1/4 (39)
15 1/4 (39)
N/A
N/A
H
IN (CM)
Height to Height to
Upper Side Lower Side
Connection Connection
3 or 4
3 or 4
2, 3 or 4
2, 3 or 4
IN
Vent
Diameter
277 (126)
200 (91)
192 (87)
174 (79)
LB (KG)
Shipping
Weight
ProLine® Direct Vent
A unique balanced flue design
Features
• Thermopile design provides robust pilot to
withstand down drafts and environmental
conditions
• LED indicator light lets you know when
pilot is in operation and provides diagnostic
capabilities
• Easy temperature adjustment
• Use outside air for combustion
• Meet latest NRCan energy efficiency standards
• No external power supply required
• 90” coaxial vent supplied with water heater
• Factory-installed plastic-lined nipples with
heat traps
• Sealed combustion chamber design,
eliminating the need for a flammable vapour
sensor
• Flame SafeTM FVIR technology
• 2 or 4 year tank warranty extension kits are
available
PERFORMANCE
Model
Series
Capacity
Input
USG (L)
BTU/h
DV40N
300/301
40 (151)
38,000
DV50N
300/301
50 (189)
40,000
DV50HIN
300/301
50 (189)
47,000
Maximum Recovery Rate
First Hour
at 90° F
Certified Temperature
Rating
Altitude
Rise
FT (M)
7,700
(2,347)
7,700
(2,347)
7,700
(2,347)
Energy
Factor
Warranty
Tank/
Parts
GPH (LPH)
GPH (LPH)
Years
42 (159)
72 (273)
0.63
6/6
43 (163)
91 (344)
0.62
6/6
51 (193)
92 (348)
0.61
6/6
For propane models sub N with P. Natural gas models are series 300. Propane models are series 301.
All models comply with national energy efficiency regulations.
14
ProLine® Direct Vent
ProLine® Direct Vent
DV50HIN*
64 3⁄8 (164)
63 5⁄8 (162)
73 (185)
DV50N
74 (188)
52 ½ (134) 49 5⁄8 (126)
54 3⁄8 (138)
64 (163)
DV40N
62 7⁄8 (160)
60 (152)
61 ¾ (157) 58 7⁄8 (150)
D
IN (CM)
C
IN (CM)
B
IN (CM)
Model
A
IN (CM)
22 (56)
22 (56)
22 (56)
E
IN (CM)
29 (74)
29 (74)
29 (74)
F
IN (CM)
Height to
Overall
Top of Diameter
Depth
Heater
Height to
Top of
Air Box
Height to Height to
Center of Top of Flue
Vent
Outlet
DIMENSIONS & SHIPPING WEIGHT
*Model has side connections.
15
10 ¾ (27)
10 ¾ (27)
10 ¾ (27)
G
IN (CM)
Height
to Drain
13 ¼ (34)
13 ¼ (34)
13 ¼ (34)
H
IN (CM)
Height
to Gas
Inlet
52 ¾ (134)
51 5⁄8 (132)
42 3⁄8 (108)
I
IN (CM)
Height
to T&P
52 ¾ (134)
N/A
N/A
I
IN (CM)
Height to
Side Tap
(Hot Out)
15 ¼ (39)
N/A
N/A
J
IN (CM)
215 (98)
200 (91)
178 (81)
LB (KG)
Height to
Shipping
Side Tap
Weight
(Cold In)
1” (25mm)
CLEARANCE TO
COMBUSTIBLES
17” (430 mm) MIN.
80” (2035 mm) MAX.
DRAIN VALVE
T&P VALVE
INLET
OUTLET
EXTERIOR
WALL
Envirosense® Power Direct Vent
96% Thermal Efficiency
Features
• Power Direct Vent design for installation versatility
vents up to 128 equivalent feet using ULC S636
PVC, CPVC or polypropylene pipe (See manual for
complete details)
• ENERGY STAR® qualified
• Side water connections for recirculating systems
• Advanced electronic control with large LCD display
• Glass-lined tank with two magnesium anode rods
• Fully submerged, spiral-shaped condensing heat
exchanger
• Concentric vent kits and condensate neutralizer kits
available
• Approved for one-pipe (PV) or two-pipe (PDV)
venting
50 Gallon Model Shown
PERFORMANCE
Model
Series
Capacity
Maximum
Certified
Altitude
Input
Recovery
Rate at 90°F
Temperature
Rise
USG
L
FT (M)
BTU/h
GPH (LPH)
Thermal
Efficiency
Warranty
Tank/
Parts
Years
NATURAL GAS
6G50100NPDVH02
140/141
50
189
10,100 (3,078)
100,000
128 (485)
96%
6/6
6G75100NPDVH02
140/141
75
284
10,100 (3,078)
100,000
128 (485)
96%
6/6
For propane models sub N with P. Natural gas models are series 140. Propane models are series 141.
All models comply with national energy efficiency regulations.
16
Envirosense® Power Direct Vent
Envirosense® Power Direct Vent
17
45 5/8 (116)
45 5/8 (116)
65 ¼ (166)
6G75100NPDVH02*
*Model has side connections.
49 ¼ (125)
49 ¼ (125)
B
IN (CM)
66 ¾ (170)
B
IN (CM)
A
IN (CM)
Height to
Upper Side
Connection
6G50100NPDVH02*
NATURAL GAS
Model
Height to
T&P
Height to
Top of Tank
DIMENSIONS & SHIPPING WEIGHT
27 ¾ (71)
22 (56)
C
IN (CM)
Tank
Diameter
16 (41)
15 ¾ (40)
D
IN (CM)
Height
to Lower
Side
Connection
3 ¾ (10)
3 (8)
E
IN (CM)
Height
to Drain
Valve
8 (20)
8 (20)
F
IN (CM)
Outlet to
Inlet
1
¾
IN
NPT
Top Water
Connections
¾
¾
IN
NPT
Side Water
Connections
½
½
IN
NPT
Gas
Connection
382 (173)
255 (116)
LB (KG)
Shipping
Weight
UPPER
PROBE
TOP VIEW
DIAMETER
FRONT VIEW
DRAIN
HOT
CONNECTION
ANODE
LOWER SIDE CONNECT
UPPER SIDE CONNECT
COLD
CONNECTION
Envirosense® Power Vent
94% Thermal Efficiency
Features
• Power Vent design for installation versatility that
vents up to 125 equivalent feet using ULC S636
PVC, CPVC or polypropylene pipe (See manual for
complete details)
• Side-mounted taps for recirculating systems
• Intelli-Vent™ gas control with silicon nitride hot
surface igniter
• Commercial-grade glass lining with two magnesium
anode rods
• Available in Natural Gas only
• Diffuser dip tube helps reduce lime and sediment
build-up to, maximize hot water output
50 Gallon Model Shown
PERFORMANCE
Model
Series
Capacity
Maximum
Certified
Altitude
Input
Recovery
Rate at 90°F
Temperature
Rise
USG
L
FT (M)
BTU/h
GPH (LPH)
50
189
5,300
(1,615)
76,000
96 (364)
Thermal
Efficiency
Warranty
Tank/Parts
Years
NATURAL GAS
6G5076NVC02
120
All models comply with national energy efficiency regulations.
18
Envirosense® Power Vent
94%
6/6
Envirosense® Power Vent
6G5076NVC02*
NATURAL GAS
Model
71 (180)
B
IN (CM)
A
IN (CM)
68 5/8 (174)
Height to
Top of Tank
Installation
Height
DIMENSIONS & SHIPPING WEIGHT
Natural gas only.
*Model has side connections.
19
52 (132)
C
IN (CM)
Height
to T&P
52 (132)
C
IN (CM)
Height to
Upper Side
Connection
21 (53)
D
IN (CM)
Height to
Lower Side
Connection
9 1/8
(23)
E
IN (CM)
Height to
Drain Valve
12 (30)
F
IN (CM)
22 (56)
G
IN (CM)
8 (20)
H
IN (CM)
Hot
Height to
Tank Connection
Thermostat Diameter to Cold
Connection
15 ¾ (40)
J
IN (CM)
Water Connection Depth From
Front of Tank
27 (69)
K
IN (CM)
Overall
Depth
¾
IN
NPT
Top Water
Connections
¾
IN
NPT
Side Water
Connections
225 (102)
LB (KG)
Shipping
Weight
INLET (L)
ANODE
DRAIN
VALVE
FRONT VIEW
THERMOSTAT
SIDE INLET
DIAMETER
T & P VALVE
SIDE OUTLET
OUTLET (L)
COLD
TOP VIEW
HOT
Polaristm
The perfect choice for combi systems
Features
• High grade stainless steel tank with brass
connections for years of dependable service
– no anode required
• A submerged combustion chamber with spiral
flue provides up to 96% thermal efficiency and
ultra-low standby heat loss of approximately 1%
• Whisper quiet operation
• Self-diagnostic control system
• Fully serviceable from the front
• Direct vents up to 120’ using ULC S636 PVC or CPVC
pipe either through the wall or through the roof
• The perfect choice for combination systems
• Modulating burner maintains high efficiency
operation at lower input rates.
PR34-100-2NV
model only
PERFORMANCE
Model
Series
Capacity
Maximum
Certified
Altitude
Input
Recovery Rate
at 90°F
Temperature
Rise
USG
L
FT (M)
BTU/h
GPH (LPH)
Thermal
Efficiency
Warranty
Tank/
Parts
Years
NATURAL GAS
PR34-100-2NV
200/201
34
129
7,700 (2,437)
100,000
129 (488)
96%
10/1
PR34-130-2NV
200/201
34
129
7,700 (2,437)
130,000
168 (636)
96%
10/1
PR34-150-2NV
200/201
34
129
7,700 (2,437)
150,000
190 (719)
94%
10/1
PR50-130-2NV
200/201
50
189
7,700 (2,437)
130,000
165 (625)
95%
10/1
PR50-150-2NV
200/201
50
189
7,700 (2,437)
150,000
190 (719)
95%
10/1
PR50-175-2NV
200/201
50
189
7,700 (2,437)
175,000
222 (840)
96%
10/1
PR50-199-2NV
200/201
50
189
7,700 (2,437)
199,000
253 (958)
96%
10/1
For propane models sub N with P. Natural gas models are series 200. Propane models are series 201.
All models comply with national energy efficiency regulations. Input, output and recovery may vary depending upon air inlet and
exhaust outlet installations, consult manual for details.
20
Polaristm
22 (56)
22 (56)
48 ½ (123)
48 ½ (123)
62 3/8 (158)
63 ¾ (162)
63 ¾ (162)
63 ¾ (162)
PR34-130-2NV
PR34-150-2NV
PR50-130-2NV
PR50-150-2NV
PR50-175-2NV
PR50-199-2NV
22 (56)
22 (56)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
C
IN (CM)
55 ¾ (142)
55 ¾ (142)
55 ¾ (142)
54 ½ (138)
40 ½ (103)
40 ½ (103)
40 ½ (103)
D
IN (CM)
Height to
Upper Side
Connection
56 ¼ (143)
56 ¼ (143)
56 ¼ (143)
55 (140)
41 (104)
41 (104)
41 (104)
E
IN (CM)
Height to T&P
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
6 3/8 (16)
G
IN (CM)
Height to
Air Inlet
6 3/8 (16)
F
IN (CM)
Height to
Gas Supply
1
1
1
1
1
1
1
IN
NPT
Water
Connections
½
½
½
½
½
½
½
IN
NPT
Gas
Connections
3
3
2 or 3
2 or 3
2 or 3
2 or 3
2 or 3
IN
Vent
Diameter
180 (82)
180 (82)
180 (82)
176 (80)
150 (68)
150 (68)
150 (68)
LB (KG)
Shipping
Weight
Gas Supply
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
15 ¾ (40)
C
IN (CM)
Height to
Cold Water
Inlet
Air Inlet
22 (56)
22 (56)
48 ½ (123)
22 (56)
B
IN (CM)
A
IN (CM)
Height to
Lower Side
Connection
LEFT SIDE
PR34-100-2NV
NATURAL GAS
Model
Tank
Diameter
Height to
Top of Tank
DIMENSIONS & SHIPPING WEIGHT
T&P Valve
Additional
Side Taps
Cold Water Inlet
Exhaust Outlet
Condensate
Drain
Outlet
FRONT
Polaristm
21
Electric
Unique features and a broad range of models
and sizes
Features
C
• Meets and exceeds NRCan energy efficiency
standards
• Wide variety of models available to meet energy
efficiency compliance standards nationwide
• Patented Styropour® base for added energy
efficiency
• Exclusive TankSaver® design to prolong tank life
• Glass-lined tank for longer life
• Factory-installed plastic-lined nipples
• Thermostatically controlled, long life elements
• Brass drain valve
• Quick recovery models available, suitable for the
builder market
• CFC-free foam insulation
• Conveniently located T&P and drain valve for ease
of installation and serviceability
• Removable anode
• 2 or 4 year tank warranty extension kits are
available for 6 year models
US
PERFORMANCE
Model
Capacity
Series
TOP ENTRY
250
E50TE-30208
250
E50TE-30240
250
E50TE-38240
250
E50TE-45208
250
E50TE-45240
250
E50TE-55208
250
E50TE-60240
250
E80TE-30208
250
E80TE-30240
250
E80TE-38240
250
E80TE-45208
250
E80TE-45240
250
E80TE-55208
250
E80TE-60240
TOP ENTRY
250
E50TEM-30240*
250
E50TEM-38240*
250
E80TEM-45240*
BOTTOM ENTRY
250
E50BE-30208
250
E50BE-30240
250
E50BE-45208
250
E50BE-45240
250
E80BE-30208
250
E80BE-30240
250
E80BE-45208
250
E80BE-45240
Elements
(Upper and Lower)
WATTS
VOLTS
First Hour
Rating
GPH (LPH)
Warranty
Tank/Parts
Years
IG
USG
L
40
40
40
40
40
40
40
60
60
60
60
60
60
60
50
50
50
50
50
50
50
80
80
80
80
80
80
80
182
182
182
182
182
182
182
287
287
287
287
287
287
287
3000
3000+
3800++
4500
4500+++
5500
6000++++
3000
3000+
3800++
4500
4500+++
5500
6000++++
208
240
240
208
240
208
240
208
240
240
208
240
208
240
53
53
53
53
53
53
53
78
78
78
78
78
78
78
60 (227)
60 (227)
60 (227)
60 (227)
60 (227)
60 (227)
60 (227)
81 (307)
81 (307)
81 (307)
81 (307)
81 (307)
81 (307)
81 (307)
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
40
40
40
50
50
50
182
182
182
3000+
3800++
4500+++
208
240
240
53
53
78
60 (227)
60 (227)
81 (307)
8/8
8/8
8/8
40
40
40
40
60
60
60
60
50
50
50
50
80
80
80
80
182
182
182
182
287
287
287
287
3000
3000+
4500
4500+++
3000
3000+
4500
4500+++
208
240
208
240
208
240
208
240
65
65
65
65
80
80
80
80
60 (227)
60 (227)
60 (227)
60 (227)
81 (307)
81 (307)
81 (307)
81 (307)
6/6
6/6
6/6
6/6
6/6
6/6
6/6
6/6
* Model has incoloy elements
All models comply with national energy efficiency regulations.
+Model is dual-rated. At 208V wattage is 2253.
++Model is dual-rated. At 208V wattage is 2854.
+++Model is dual-rated. At 208V wattage is 3380.
++++Model is dual-rated. At 208V wattage is 4507.
22
Standby
Loss
WATTS
ProLine® & ProLine® Master Electric
COLD
CONNECTON
ANODE ROD
HOT
CONNECTON
DIMENSIONS & SHIPPING WEIGHT
Model
TOP ENTRY
E50TE-30208
E50TE-30240 / E50TEM-30240
E50TE-38240 / E50TEM-38240
E50TE-45208
E50TE-45240
E50TE-55208
E50TE-60240
E80TE-30208
E80TE-30240
E80TE-38240
E80TE-45208
E80TE-45240 / E80TEM-45240
E80TE-55208
E80TE-60240
BOTTOM ENTRY
E50BE-30208
E50BE-30240
E50BE-45208
E50BE-45240
E80BE-30208
E80BE-30240
E80BE-45208
E80BE-45240
Height to Top of
Tank
A
Diameter
B
Shipping Weight
IN (CM)
IN (CM)
LB (KG)
48 3/4 (124)
48 3/4 (124)
48 3/4 (124)
48 3/4 (124)
48 3/4 (124)
48 3/4 (124)
48 3/4 (124)
60 1/2 (154)
60 1/2 (154)
60 1/2 (154)
60 1/2 (154)
60 1/2 (154)
60 1/2 (154)
60 1/2 (154)
22 (56)
22 (56)
22 (56)
22 (56)
22 (56)
22 (56)
22 (56)
24 (61)
24 (61)
24 (61)
24 (61)
24 (61)
24 (61)
24 (61)
125 (57)
125 (57)
125 (57)
125 (57)
125 (57)
125 (57)
125 (57)
170 (77)
170 (77)
170 (77)
170 (77)
170 (77)
170 (77)
170 (77)
48 (122)
48 (122)
48 (122)
48 (122)
60 1/2 (154)
60 1/2 (154)
60 1/2 (154)
60 1/2 (154)
22 (56)
22 (56)
22 (56)
22 (56)
24 (61)
24 (61)
24 (61)
24 (61)
122 (55)
122 (55)
122 (55)
122 (55)
170 (77)
170 (77)
170 (77)
170 (77)
ProLine® & ProLine® Master Electric
23
Space Saver® Electric
Put hot water right where you need it
Features
• Designed for installation in cottages, offices,
mobile homes and other applications where
space is limited
• Meets NRCan energy efficiency standards
• Personnel protector covers elements and
controls for added safety
C
PERFORMANCE
Capacity
Model
Recovery
Warranty
Rate at 90°F Standby
Tank/
Temperature Loss
Parts
Rise
Input
Series
IG
USG
PLUG IN SINGLE ELEMENT MODEL
SS025SE15
N/A
2
2.5
BOTTOM ENTRY SINGLE ELEMENT MODELS
SS06SEB15
N/A
5
6
SS06SEB30
N/A
5
6
SS12SEB15
N/A
9
12
SS12SEB30
N/A
9
12
SS620SSEB-15K
100
14
19
SS620SSEB-30
100
14
19
SS630SSEBN-15K 100
22
30
SS630SSEBN-30
100
22
30
TOP ENTRY DOUBLE ELEMENT MODELS
SS640SDE3-15K
100
30
40
SS640SDE3-30X
100
30
40
SS640SDE3-30
100
30
40
LOWBOY TOP ENTRY DOUBLE ELEMENT MODELS
SS630LDE-45
250
22
30
SS640LDE-45
250
30
40
SS650LDE-45
250
40
50
US
L
WATTS
VOLTS
GPH (LPH)
WATTS
Years
10
1500
120
7 (26)
N/A
5/1
23
23
43
43
65
65
108
108
1500
3000+
1500
3000+
1500
3000+
1500
3000+
120
240
120
240
120
240
120
240
7 (26)
14 (53)
7 (26)
14 (53)
7 (26)
14 (53)
7 (26)
14 (53)
N/A
N/A
N/A
N/A
51
51
48
48
6/1
6/1
6/1
6/1
6/1
6/1
6/1
6/1
143
143
143
1500
3000
3000+
120
208
240
7 (26)
14 (53)
14 (53)
54
54
54
6/1
6/1
6/1
108
143
182
4500++
4500++
4500++
240
240
240
20 (76)
20 (76)
20 (76)
53
62
64
6/1
6/1
6/1
All models except LOWBOY TOP ENTRY DOUBLE ELEMENT MODELS are BC/ON compliant. SS630LDE-45 and SS640LDE-45 are
ON compliant.
+Model is dual-rated. At 208V wattage is 2253.
++Model is dual-rated. At 208V wattage is 3380.
24
Space Saver® Electric
Bottom Entry Model
Top Entry Model
DIAMETER
HEIGHT
DIAMETER
HEIGHT
DIMENSIONS & SHIPPING WEIGHT
Height
Diameter*
Width
Shipping
Weight
A
IN (CM)
B
IN (CM)
C
IN (CM)
LB (KG)
11 (28)
14 (36)
20 (9)
14 ¼ (36)
14 ¼ (36)
16 (41)
16 (41)
20 (51)
20 (51)
22 (56)
22 (56)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
35 (16)
35 (16)
55 (25)
55 (25)
65 (30)
65 (30)
101 (46)
101 (46)
22 (56)
22 (56)
22 (56)
N/A
N/A
N/A
103 (47)
103 (47)
103 (47)
22 (56)
24 (61)
26 ½ (67)
N/A
N/A
N/A
96 (44)
113 (51)
164 (74)
Model
PLUG IN SINGLE ELEMENT MODEL
SS025SE15
14 (36)
BOTTOM ENTRY SINGLE ELEMENT MODELS
SS06SEB15
15 ¼ (39)
SS06SEB30
15 ¼ (39)
22 ¾ (58)
SS12SEB15
SS12SEB30
22 ¾ (58)
25 ½ (65)
SS620SSEB-15K
SS620SSEB-30
25 ½ (65)
SS630SSEBN-15K
30 (76)
SS630SSEBN-30
30 (76)
TOP ENTRY DOUBLE ELEMENT MODELS
SS640SDE3-15K
50 (127)
SS640SDE3-30X
50 (127)
SS640SDE3-30
50 (127)
LOWBOY TOP ENTRY DOUBLE ELEMENT MODELS
SS630LDE-45
31 (79)
SS640LDE-45
33 ½ (85)
SS650LDE-45
34 (86)
*Depth on model SS025SE15
Space Saver® Electric
25
Oil-Fired
Models for virtually every application
Features
• Glass-lined inner tank and sacrificial
magnesium anodes extend tank life
• Universal mounting design fits most burners
• Ceramic fibre combustion chamber maximizes
heat retention
• Supplied with a blocked flue safety switch
• Suitable for combination applications, potable
water and space heating
C
US
Oil burners designed by BeckettTM
• Easy to install
• AFG Burner comes with Beckett Clean Cut Fuel Unit, Beckett R7184 Series 5
Primary Control, self-centering Nozzle Line Electrode Assembly and one piece
Flame Retention Head
PERFORMANCE
Model
Series
Capacity
Input
USG (L)
BTU/h
Recovery
Standard
Warranty
Rate at 90°F First Hour
Firing
Temperature Rating Energy Tank/Parts*
Rate
Factor
Rise
USG/h
GPH (LPH) GPH (LPH)
Years
CENTER-FLUE
JW6 F307
400
32 (121) 84,000 - 105,000 0.60 - 0.75
120 (454)
113 (428)
0.62
6/1*
JW6 F507
400
50 (189)
105,000
0.75
126 (477)
145 (549)
0.62
6/1*
32 (121)
91,000
0.65
103 (390)
113 (428)
0.62
6/1*
DIRECT VENT**
JW6 F307V
400
*Burners are sold separately and warrantied by the burner manufacturer.
**Direct vent models must use vent kit and burner supplied by John Wood®. Burner must be model specified
with pre-purge and post-purge features.
All models comply with national energy efficiency regulations.
26
Oil-Fired
Oil-Fired
27
Beckett oil burner for JW6 F307V, single aquastat
Beckett oil burner for JW6 F307V, dual aquastat
10’ vent kit, includes termination, cage and adapter
20’ vent kit, includes termination, cage and adapter
3” clamp and teflon gasket
6” clamp and teflon gasket
CENTER-FLUE
GSW1801 Beckett oil burner, for model JW6 F307, single aquastat
GSW1802 Beckett oil burner, for model JW6 F307, dual aquastat
GSW1901 Beckett oil burner for JW6 507, single aquastat
GSW1902 Beckett oil burner for JW6 507, dual aquastat
Description
172 (78)
214 (97)
172 (78)
LB (KG)
Shipping Weight
Description
3/4
3/4
3/4
IN
(NPT)
Water Connection
DIRECT VENT
GSW2001
GSW2002
100092474
100092475
100092507
100092508
4 3/4 (12)
5 3/4 (15)
4 3/4 (12)
IN (CM)
Tube Insertion
Length
Part Number
6 (15)
6 (15)
6 (15)
D
IN (CM)
Vent Diameter
OIL BURNERS, VENT KITS & GASKETS
20 (51)
22 (56)
20 (51)
C
IN (CM)
Tank Diameter
Part
Number
50 5/8 (129)
58 1/2 (149)
50 5/8 (129)
Height to Top of
Tank
B
IN (CM)
OIL BURNERS, VENT KITS & GASKETS
JW6 F307V
52 3/4 (134)
60 1/2 (154)
DIRECT VENT
52 3/4 (134)
JW6 F507
A
IN (CM)
Installation Height
JW6 F307
CENTER-FLUE
Model
DIMENSIONS & SHIPPING WEIGHT
5’,10’ or 20’ kits
available for
JWF307V
(Factory length not
to be altered)
Storage Booster Tanks
Exclusive, patented innovation
Features
• Available in 40, 50, and 80 gallon
capacities to meet the hot water
requirements of modern households
• Glass-lined inner tanks for long life
• Automatic temperature control through
adjustable thermostat
• 6-year tank warranty
1-year parts warranty
DIMENSIONS & SHIPPING WEIGHT
Capacity
Water
Connections
Height to
Top of Tank
Tank
Diameter
Height to
T&P
Approximate
Shipping
Weight
USG (L)
IN
(NPT)
IN (CM)
IN (CM)
IN (CM)
LB (KG)
3/4
40 (102)
37 3/4 (96)
103 (47)
Model
HOT OUTLET
SUPPLY (TO BOILER
TANKLESS COIL)
JUNCTION
BOX
ANODE
JWSB-40
40 (151)
T&P VALVE
20 1/2 (52)
ACCESS
DOORS
JWSB-50
50 (189)
3/4
48 (122)
21 1/2 (55)
40 1/2 (103)
123 (56)
JWSB-80
80 (303)
3/4
60 1/2 (154)
22 1/2 (57)
52 (132)
175 (79)
THERMOSTAT
CONTROL
THERMOSTAT
RETAINER
COMBINATION
RETURN & DRAIN
VALVE
CHECK VALVE
EXPANSION TANK
(OPTIONAL)
CIRCULATOR
PUMP
PRESSURE
REGULATOR
(OPTIONAL)
HOT
SUPPLY (TO BOILER
TANKLESS COIL)
COLD
HOT OUTLET
JUNCTION
BOX
T&P
VALVE
HOT
TANKLESS COIL BOILER
ANODE
T&P VALVE
STORAGE
BOOSTER
TANK
ACCESS
DOORS
THERMOSTAT
CONTROL
THERMOSTAT
RETAINER
COMBINATION
RETURN & DRAIN VALVE
COMBINATION
RETURN & DRAIN
VALVE
CHECK VALVE
EXPANSION TANK
(OPTIONAL)
CIRCULATOR
PUMP
28
PRESSURE
REGULATOR
(OPTIONAL)
HOT
Storage Booster Tanks
COLD
T&P
VALVE
TANKLESS COIL BOILER
Flow THRU®
Storage tanks specifically designed to complement
our series of tankless water heaters
Features
• Exclusive TankSaver® design works to prolong
tank life
• Factory-installed dielectric nipples for ease of
installation
• T&P valve conveniently located on the side
• Top access junction box for convenient
electrical hook-up
• Equipped with an adjustable thermostat,
pre-wired and ready for connection to a
circulator pump
• 6-year tank warranty
1-year parts warranty
C
US
Flow THRU®
29
Flow THRU®
Series
200
200
Model
GST 20
GST 30
SPECIFICATIONS
30
30
19
USG
Capacity
108
67
L
31 ½ (80)
25 ½ (65)
A
IN (CM)
Height
22 (56)
19 (48)
B
IN (CM)
Diameter
¾
¾
IN
NPT
Water
Connections
94 (43)
65 (29)
LB (KG)
Shipping Weight
A
B
Tankless
Tankless
SPECIFICATIONS CHART
7
Powered by
The John Wood powered by Takagi condensing tankless water
heaters provide endless hot water *. The durable primary heat
exchanger is made of commercial-grade copper while the secondary
heat exchanger is made of Type 316L stainless steel, preventing
corrosion and prolonging the life of the heater. These direct vent
models combine durability and versatility in an easy-to-install
space-saving design.
Features of Condensing Tankless Models:
• Integrated temperature and error display
• Advanced safety features
• ENERGY STAR® qualified with a 0.95 EF
• ULC S636 PVC, CPVC, polypropylene pipe or Cat. III/IV stainless steel venting
• Internal freeze protection system
• New 540P model with integrated recirculation pump
*When sized appropriately
John Wood® powered by Takagi Tankless
High-efficiency condensing models
Features
C
• ENERGY STAR® qualified
• 0.95 Energy Factor
• Durable primary heat exchanger is made of
commercial-grade copper while the secondary heat
exchanger is made of Type 316L stainless steel,
preventing corrosion and prolonging the life of the
heater
• Available inputs: up to 199,000 BTU
• New 540P model with integrated recirculation
pump
• Can be vented using ULC S636 PVC, CPVC,
polypropylene pipe or Cat. III/IV stainless steel
• Factory-installed power cord and integrated controls
• Concentric vent kit available
• Fully modulating
• Easy-link up to 4 units with no additional accessories
(JWT-540 model only)
• Multi-link up to 20 units with a multi-unit controller
(JWT-540H model only)
• 15-year limited warranty on heat exchanger in
residential applications
• 6-year limited warranty on heat exchanger in
commercial applications
• 5-year limited warranty on all parts
US
Flow Rate Guide
Temperature Rise vs. Gallons per minute
Temperture Rise (°F)
JWT-240H
JWT-340H
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
6.6
6.6
6.6
6.6
6.1
5.5
5.1
4.7
4.3
4.1
3.8
3.6
3.4
3.2
3.0
8.0
8.0
8.0
7.6
6.8
6.2
5.7
5.3
4.9
4.6
4.3
4.0
3.8
3.6
3.4
Flow rate is determinded by temperature rise. To determine your temperature rise,
subtract the incoming water temperature from the set output temperature. All units
are factory set to 120ºF or 122ºF but can be changed.
Flow rates are based on default set temperatures.
34
John Wood® powered by Takagi Tankless (Condensing)
JWT-540H
JWT-540P
10.0
10.0
9.5
8.4
7.6
6.9
6.3
5.8
5.4
5.0
4.7
4.4
4.2
4.0
3.8
John Wood® powered by Takagi Tankless (Condensing)
35
JWT-240H-DV-N
JWT-340H-DV-N
JWT-540H-DV-N
JWT-540P-N
PROPANE
JWT-240H-DV-P
JWT-340H-DV-P
JWT-540H-DV-P
JWT-540P-P
NATURAL GAS
Model
15,000 - 160,000
15,000 - 180,000
15,000 - 199,000
15,000 - 199,000
13,000 - 160,000
13,000 - 180,000
13,000 - 199,000
15,000 - 199,000
Residential
Residential
Residential/Commercial
Residential/Commercial
BTU/h
Input
Residential
Residential
Residential/Commercial
Residential/Commercial
Application
PERFORMANCE & DIMENSIONS
4.3
4.9
5.4
5.4
4.3
4.9
5.4
5.4
Flow Rate GPM
at 70°F Rise
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
Energy
Factor
22 1/2 (57)
22 1/2 (57)
22 1/2 (57)
23 5/8 (60)
22 1/2 (57)
22 1/2 (57)
22 1/2 (57)
23 5/8 (60)
IN (CM)
Height
17 3/4 (45)
17 3/4 (45)
17 3/4 (45)
17 3/4 (45)
17 3/4 (45)
17 3/4 (45)
17 3/4 (45)
17 3/4 (45)
IN (CM)
Width
11 ¼ (29)
10 3/4 (27)
10 3/4 (27)
10 3/4 (27)
11 ¼ (29)
10 3/4 (27)
10 3/4 (27)
10 3/4 (27)
IN (CM)
Depth
58 (26)
58 (26)
59 (27)
61 (28)
58 (26)
58 (26)
59 (27)
61 (28)
LB (KG)
Shipping Weight
John Wood® powered by Takagi Tankless
Non-condensing models
Features
LOW LEAD
ANSI Z21.10.3
• Durable primary heat exchanger is made of
commercial-grade copper which has 8 times
the tensile strength of standard copper and
prevents corrosion, prolonging the life of
the heater
• Built-in freeze protection
• Advanced safety features help prevent scalding
dangers
• Factory-installed power cord
• Easy-link up to 4 units with no additional
accessories (JWT-910 model only)
• Multi-link up to 10 units with a multi-unit
controller (JWT-910 model only)
• 15-year limited warranty on heat exchanger
in residential applications
• 6-year limited warranty on heat exchanger
in commercial applications
• 5-year limited warranty on all parts
ANSI Z21.10.3 CSA 4.3
Flow Rate Guide
Temperature Rise vs. Gallons per minute
Temperture Rise (°F)
JWT-110
JWT-310
JWT-510
JWT-910
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
6.6
6.6
5.7
5.1
4.6
4.2
3.8
3.5
3.3
3.1
2.9
2.7
2.5
2.4
2.3
8.0
8.0
7.8
6.9
6.2
5.7
5.2
4.8
4.4
4.1
3.9
3.7
3.5
3.3
3.1
10.0
9.3
8.1
7.2
6.5
5.9
5.4
5.0
4.7
4.3
4.1
3.8
3.6
3.4
3.3
14.5
14.5
14.5
13.5
12.2
11.1
10.1
9.4
8.7
8.1
7.6
7.2
6.8
6.4
6.1
Flow rate is determinded by temperature rise. To determine your temperature rise,
subtract the incoming water temperature from the set output temperature. All units
are factory set to 120ºF or 122ºF but can be changed.
Flow rates are based on default set temperatures.
36
John Wood® powered by Takagi Tankless (Non-Condensing)
John Wood® powered by Takagi Tankless (Non-Condensing)
37
19,500 - 140,000
11,000 - 190,000
11,000 - 199,000
15,000 - 380,000
15,000 - 380,000
19,500 - 140,000
11,000 - 190,000
11,000 - 199,000
15,000 - 380,000
15,000 - 380,000
Residential
Residential
Residential
Commercial
Commercial
BTU/h
Residential
Residential
Residential
Commercial
Commercial
Application
Input Range
3.3
4.4
4.7
8.7
8.7
3.3
4.4
4.7
8.7
8.7
Flow Rate
GPM at 70°F
Rise
0.83
0.82
0.82
N/A*
N/A*
0.82
0.82
0.83
N/A*
N/A*
Energy
Factor
20 1/4 (52)
20 1/4 (52)
20 1/4 (52)
25 1/4 (64)
25 1/4 (64)
20 1/4 (52)
20 1/4 (52)
20 1/4 (52)
25 1/4 (64)
25 1/4 (64)
IN (CM)
Height
13 3/4 (35)
13 3/4 (35)
13 3/4 (35)
24 7/8 (63)
24 7/8 (63)
13 3/4 (35)
13 3/4 (35)
13 3/4 (35)
24 7/8 (63)
24 7/8 (63)
IN (CM)
Width
* JWT-910N and JWT-910P have a thermal efficiency of 80%. JWT-910AN and JWT-910AP have a thermal efficiency of 82%.
**ASME models
NATURAL GAS
JWT-110-N
JWT-310-N
JWT-510-N
JWT-910-N
JWT-910-AN**
PROPANE
JWT-110-P
JWT-310-P
JWT-510-P
JWT-910-P
JWT-910-AP**
Model
PERFORMANCE & DIMENSIONS
7 3/4 (20)
9 1/2 (24)
9 1/2 (24)
12 1/4 (31)
12 1/4 (31)
7 3/4 (20)
9 1/2 (24)
9 1/2 (24)
12 1/4 (31)
12 1/4 (31)
IN (CM)
Depth
33 (15)
38 (17)
39 (18)
112 (51)
112 (51)
33 (15)
38 (17)
39 (18)
112 (51)
112 (51)
LB (KG)
Shipping
Weight
John Wood® powered by Takagi Tankless
Non-condensing concentric vent models
Features
• Concentric vent design
• Field convertible from natural gas to
propane
• Maximum flow rates up to 10.0 GPM
• Copper heat exchanger: 25x better heat
transfer than stainless steel
• Easy-Link up to 4 units with no additional
parts or accessories needed (JWT-510C only)
• Multi-link up to 20 units with a Multi-Unit
Controller (JWT-510C only)
• Built-in freeze protection
• 15-year limited warranty on heat exchanger
in residential applications
• 6-year limited warranty on heat exchanger
in commercial applications
• 5-year limited warranty on all parts
LOW LEAD
(510C-NI models only)
ANSI Z21.10.3
Flow Rate Guide
Temperature Rise vs. Gallons per minute
Temperture Rise (°F)
JWT-110C
JWT-310C
JWT-510C
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
6.6
6.6
5.7
5.1
4.6
4.2
3.8
3.5
3.3
3.1
2.9
2.7
2.5
2.4
2.3
8.0
8.0
7.8
6.9
6.2
5.7
5.2
4.8
4.5
4.1
3.9
3.7
3.5
3.3
3.1
10.0
9.3
8.1
7.2
6.5
5.9
5.4
5.0
4.7
4.3
4.1
3.8
3.6
3.4
3.3
Flow rate is determinded by temperature rise. To determine your temperature rise,
subtract the incoming water temperature from the set output temperature. All units
are factory set to 120ºF or 122ºF but can be changed.
Flow rates are based on default set temperatures.
38
John Wood® powered by Takagi Tankless (Non-Condensing Concentric Vent)
John Wood® powered by Takagi Tankless (Non-Condensing Concentric Vent)
39
NATURAL GAS
JWT-110C-NI
JWT-310C-NI
JWT-510C-NI
Model
Residential
Residential
Residential
Application
PERFORMANCE & DIMENSIONS
15,000 - 140,000
15,000 - 190,000
15,000 - 199,000
BTU/h
Input Range
3.3
4.5
4.7
Flow Rate
GPM at 70°F
Rise
0.82
0.82
0.82
Energy
Factor
20 1/2 (53)
20 1/2 (53)
20 1/2 (53)
IN (CM)
Height
13 3/4 (35)
13 3/4 (35)
13 3/4 (35)
IN (CM)
Width
10 1/2 (27)
10 1/2 (27)
10 1/2 (27)
IN (CM)
Depth
51 (23)
51 (23)
51 (23)
LB (KG)
Shipping
Weight
Appendices
Appendices
Reference Calculations and Conversions for Electricity
Ohm’s Law
Ohm’s Law defines the relationships between (P) power, (E) voltage, (I) current, and (R)
resistance. One ohm is the resistance value through which one volt will maintain a current of
one ampere.
(I) Current is what flows on a wire or conductor like water flowing down a river. Current flows
from points of high voltage to points of low voltage on the surface of a conductor. Current is
measured in (A) amperes or amps.
(E) Voltage is the difference in electrical potential between two points in a circuit. It’s the push
or pressure behind current flow through a circuit, and is measured in (V) volts.
(R) Resistance determines how much current will flow through a component. Resistors are
used to control voltage and current levels. A very high resistance allows a small amount of
current to flow. A very low resistance allows a large amount of current to flow. Resistance is
measured in ohms.
(P) Power is the amount of current times the voltage level at a given point measured in
wattage or watts.
42
Appendices
Reference Guide for Water Heating
One US gallon of fresh water weighs 8.333 lb.
Water expands 4.34% heated from 40o to 212o F.
1 BTU = Amount of heat required to raise the temperature of 1 lb. of water 1o F.
Recovery GPH = (Electric) KW x 3412
8.33 x ∆T
Recovery GPH =
(Gas)
Input x Efficiency
8.33 x ∆T
Req. BTU Input = Water Heater Capacity x 8.33 x ∆T
% Efficiency
First Hour Draw (FHD)
FHD = (Storage x % Efficiency) + Recovery
% of hot and cold water needed to be mixed to obtain a desired temperature
Hot water percentage =
M-C
H-C
Cold water percentage =
H-M
H-C
Water C = Cold Water Temperature
H = Hot Water Temperature
M = Mixed Water Temperature
% Efficiency =
GPH x 8.33 x Temp. Rise
BTU/Hr. Input
43
Appendices
Reference Guide for Water Heating
BTU/Output = GPH x 8.33 lbs./Gal. x Temp. Rise
BTU/Input =
GPH x 8.33 x Temp. Rise
% Efficiency
KW = GPH x 8.33 x Temp. Rise
3413
Temperatures
To convert from degrees Centigrade (C) to degrees Fahrenheit (F) multiply the
number of degrees C by 9/5 (or 1.8) and add 32.
To convert from degrees Fahrenheit (F) to degrees Centigrade (C) first subtract 32
from the number of degrees F then multiply the remainder by 5/9 (or 0.556).
Gas/Oil
GasBTU
1 lb. of Butane
1 Gal. of Butane
1 Cu. Ft. of Butane
1 Cu. Ft. of Manufactured
1 Cu. Ft. of Mixed
1 Cu. Ft. of Natural
1 lb. of Propane
1 Gal. of Propane
1 Cu. Ft. of Propane
44
=
=
=
=
=
=
=
=
=
21,300
102,600
3,260
530
850
1,075
21,600
91,700
2,570
Appendices
Reference Guide for Water Heating
Oil vs. Electric vs. Propane vs. Natural Gas
Oil
1 litre = 36,515 BTUs*
Example Price = 60.0¢/litre
Electric
1 Kilowatt Hour = 3,413 BTUs*
Example Price = 10.1¢/KW (kilowatt)
Propane
1 litre = 24,197 BTUs*
Example Price = 63.0¢/litre
Natural Gas
1 M3 35,310 BTUs*
Example Price = 44.0¢/M3 (cubic metre)**
Formula
BTUs per Unit x Efficiency
Cost per Unit
Example:
Propane = 24,197 x 92% = 35335 BTUs per $1.00
0.63
GST is extra on all prices.
* Information supplied by The Ontario Ministry of Energy.
** This price reflects delivery charge and monthly administration charge to service
your account.
Formulas and Facts
• 1 gallon of water weighs 8.33 lbs.
• 1 gallon of water has a volume of 231 cubic inches
• 1 cubic foot of water weighs 62.38 lbs. and contains 7.48 gallons
of water
• 100 feet of 3/4” copper pipe contains 2.5 gallons of water; 1” pipe contains 4.3 gallons
• 8.33 BTU will raise 1 gallon of water 1o F at 100% efficiency (electricity)
45
Appendices
Reference Guide for Water Heating
• 11 BTUs are required to raise 1 gallon of water 1o F at 70% efficiency (gas)
• 3,412 BTUs equal 1 kilowatt hour (KW)
• 1 KW will raise 410 gallons of water 1o F at 100% efficiency
• 1 BTU x 0.293 = watts
• 1 KW = 1000 watts
• 2.42 watts are required to raise 1 gallon of water 1o F
1 KW will raise 10.25 gallons of water 40o F at 100% efficiency
1 KW will raise 6.8 gallons of water 60o F at 100% efficiency
1 KW will raise 5.1 gallons of water 80o F at 100% efficiency
1 KW will raise 4.1 gallons of water 100o F at 100% efficiency
Formula for mixing hot water
M-C
= Percent of hot water required to produce desired mixed temperature
H-C
Where M = mixed water temperature; C = cold water temperature;
H = hot water temperature
For example: How much of a shower is hot water and how much is cold water?
My shower temperature is 105o F, my water heater thermostat is set on 120o F and the cold water inlet temperature is 50o F.
105 – 50 = 55
120 – 50 = 70
= 79% of the shower is 120o hot water
This formula for mixing hot water is important when explaining a NOT ENOUGH
HOT WATER trouble call and the water heater is functioning properly.
46
Appendices
Reference Guide for Water Heating
ELECTRIC
GAS
Energy Costs:
Energy Costs:
KW x fuel costs = energy costs
Cubic feet x fuel costs = energy costs
100 x 0.05 = $5.00
100 x 0.75 = $7.50
To obtain gallons per hour
(GPH) recovery
WATTS
2.42 x (temp rise o F)
To obtain gallons per hour
(GPH) recovery
HOURLY INPUT (BTUs)
11.0 x (temp rise o F)
I have a 30-gallon electric heater,
non-simultaneous operation, 4,500 watt
elements. What is the recovery GPH if my
cold water is 40o F and my thermostat is
set to 120o F?
I have a 30-gallon gas heater,
rated at 40,000 BTUs. What is the recovery
GPH if my cold water is 40o F and my
thermostat is set to 120o F?
4,500
2.42 x 80
= 23 gallons per hour
40,000
11.0 x 80
= 45 gallons per hour
Temperature Rise (o F)
WATTS
2.42 x GPH
Temperature Rise (o F)
H OURLY INPUT (BTUs)
11.0 x GPH
I have a 30-gallon electric heater,
non-simultaneous operation, 4,500
watt elements. What is the maximum
temperature rise if the heater can recover
23 gallons per hour?
4,500
= 80o temp
2.42 x 23 rise
I have a 30-gallon gas heater,
rated at 40,000 BTUs. What is the maximum
temperature rise if the heater can recover 45
gallons per hour?
40,000
11.0 x 45 rise
= 80o temp
47
Appendices
Reference Guide for Water Heating
Oil
1 Gal. #1 Fuel
1 Gal. #2 Fuel
1 Gal. #3 Fuel
1 Gal. #5 Fuel
1 Gal. #6 Fuel
1 lb. of Gas = 28” Water Column
1 lb. of Gas = 16 oz.
100 Cu. Ft. = 1 therm.
=
=
=
=
=
BTU
136,000
138,500
141,000
148,500
152,000
Conversions
Multiply
By
To Obtain
BTU/HR
0.293
W
Ft.
0.3048
m
Ft./min., fpm
0.00508
m/s
Ft.2
0.0929m2
3
Ft. 0.0283m3
3
Gallon (U.S. 231 in )3.79
L
Gallon
0.00379
m3
Horsepower (boiler)
9.81
KW
Inch
25.4
mm
Mile
1.61
km
Pound lb. (mass)
0.454
kg
Psi
6.89
kPa
48
Appendices
Exclusive Designs, Built-to-Last
John Wood® Water Heaters are designed and built with
features to ensure maximum quality, safety and reliability. Our
heaters are thoroughly factory tested, field-proven and meet or
exceed industry standards.
TankSaver®
T he exclusive TankSaver® design prolongs tank life. TankSaver®
impedes corrosion by guarding metal tank openings from exposure
to water and keeping them watertight. The durable construction
virtually eliminates rust.
Certified Hydrostatic Tests
Design test pressure - 300 psi. Maximum working pressure - 150 psi.
NRCan Standard
All John Wood water heaters meet or exceed NRCan energy
efficiency standards.
Coast-to-Coast Service & Support
In order to bring you unsurpassed quality and reliability after you’ve
purchased a John Wood product, we’ve created a number of service
and support resources to help take you through installation and
beyond. Operating hours are 8:00 a.m. to 6:00 p.m. EST for our
Technical Support call centre (1-888-479-8324), which is staffed
by technical experts who provide in-depth product support and
troubleshooting advice. We offer a wide-range of hands-on training
programs from basic refresher courses to product-specific programs.
Our spare parts inventory carries a comprehensive supply of parts to
help make repairs fast and easy.
49
Notes
50
Notes
Head Office:
599 Hill Street West
Fergus, ON N1M 2X1
Tel.: 1-800-447-6575
Fax: 519-787-5500
Technical Service & Warranty:
Tel.: 1-888-479-8324
Sales & Customer Service:
Tel.: 1-888-599-2837
info@johnwoodwaterheaters.com
www.johnwoodwaterheaters.com