Notice 2700990 rev1_Centrale Allarme H4_ing.qxp

H4 Alarm Control Unit
with siren
and telephone transmitter
Installation and use
instructions
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
2
INDEX
1 - PRESENTATION
Presentation of the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Presentation of H4 alarm control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2 - INSTALLATION
Indicator lights status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Preparation - Positioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Securing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
3 - PROGRAMMING
Go to Add devices mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Registering devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Deleting devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Areas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
4 - CUSTOMISING THE SYSTEM
Access to the telephone transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Modifying the system parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Control Unit internal functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
System test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
5 - USE
Status diagram (use with radio control) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
System management in local mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Management by telephone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Indicator lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Signals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
6 - HOW AN ALARM TAKES PLACE
Operation of telephone calls during an alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
7 - ENCLOSURES
Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Customised configuration panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
CE Declaration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
3
1
PRESENTATION
This system's devices communicate on two different
frequency bands: the messages emitted between
the control unit, the detectors, and the warning
indicators are sent simultaneously on the following
two frequencies: 434 and 868 MHz.
Maximum capacity of the elements supported by the
system:
- various detectors
40 max
- remote-controls
14 max
- emergency call panic buttons
4 max
- control keypads
4 max
- transmitters
2 max
- sirens
4 max
This guarantees the sending of information,
irrespective of the environment and of the attempts
to disturb one of the frequencies.
The security of every element is guaranteed thanks
to a unique identifier and to periodic supervision by
radio.
PRESENTATION OF THE SYSTEM
2 Detect
Movement
detector
1 Control
C
-
OK
Opening
detector
3 Analyse,
process
INFO
+
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Control keypad
Passage open signal
Alarm control unit
with siren and
telephone
transmitter
4-key
remote-control
Outdoor siren
Outdoor siren with
flashing light
4 Signal - alert
4
THE AREAS (AREA 1 - AREA 2 - AREA 3 - AREA 4)
The areas can be selected from a control keypad (Area from 1 to 4).
The configuration of the areas, i.e. the enablement of the detectors, is done by a keypad and by the detectors
to be integrated in each area.
The control unit can protect the whole of an ambient/room or just part of it.
first floor
ground floor
staircases
AMBIENT TO BE PROTECTED
4 areas (A1, A2, A3,and A4) are available on
the control unit.
garage
SYSTEM MODE ON
Each detector can belong to different areas (possible
overlapping).
EXAMPLES OF AREAS
The garage detector is associated with areas 1, 2 and 4 (A1, A2 and A4).
One area at a time can be enabled.
AREA 1
AREA 2
AREA 3
AREA 4
5
PRESENTATION OF H4 ALARM CONTROL UNIT
The siren control unit is the main part of the alarm
system. It analyses the detectors' messages,
transmits the alarm toward the siren and
automatically calls up to 4 telephone numbers.
signalling
indicator lights
(system statuses)
The transmission control unit manages intrusion
detections and domestic risks.
A powerful 102 dB siren is integrated in it.
It can operate either in system mode on, or in partial
mode (areas).
operation
indicator light
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
operation
options selector
Peripheral units fault /
Telephone line fault
Passage open signal
front side
securing screw
battery
compartment
EFF
AP
TEST
delete push-button
TEST push-button
key to open
battery
compartment
front side
securing screws
battery
compartment
sabotage
Internal view of the control unit
Cable route
The control unit has:
- a telephone output to be connected to the telephone
network,
- two outputs supplying status information and alarm
information (see specific chapter).
Sabotage
route
Status report
and alarm
report board
6
INDICATOR LIGHTS STATUS
Fault indicator
lights
Operation indicator
light (yellow)
OFF
flash 0.1s / 1s
lighted on steady beam
lighted on steady beam ADD DEVICES menu status
flashes 0.5s / 0.5s
flashes 0.5s / 0.5s
MAINTENANCE PROGRAM mode
AREA CREATION menu status
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
AP
TEST
EFF
TEST push-button
DELETE push-button
ADD DEVICES menu
MAINTENANCE PROGRAM mode
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory stored / In progress
Detector
Alarm memory-stored / In progress
1
Sabotage memory stored
2
Sabotage in progress
except control unit
Remote-control
System sabotage alarm
Control keypad
Discharged batteries
Telephone transmitter
Peripheral units fault /
Telephone line fault
Siren
Passage open signal
3
Battery fault in progress
4
Peripheral units fault or
telephone line fault
5
Perimetric fault
EFF
TEST
AP
Status of red signal indicator lights
In ADD DEVICES menu
(Yellow operation
indicator light:
)
In AREA CREATION
menu
(Yellow operation
indicator light:
)
A device is present
No devices
A detector is present in the area (X)
No detectors in the area (X)
7
2
INSTALLATION
PREPARATION - POSITIONING
„ Choice of location
Before installing, you must adequately select the
place where the control unit will be located (for the
other devices, consult the relevant instructions).
Radio wave propagation rate:
„ Installation precautions
plaster, wood,
plasterboard
reinforced
concrete
from 90 to 100%
from 10 to 70%
The radio waves in the room are reflected and
attenuated, according to the structures they
encounter.
Propagation may be altered and, therefore, the
devices must not be installed near large metal
masses (beams…), or near an electrical panel.
brick,
agglomerate
metal, metallic
protection
from 65 to 95%
from 0 to 10%
„ Locating the control unit
- On a flat surface, with sufficient space around, to
enable the battery compartment to be installed and
opened.
- At the centre of the system and high up, to ensure
better radio connection (avoid underground rooms).
- In an obstacle-free place, for excellent sound
diffusion of the integrated siren.
- In a place difficult to reach by an intruder, but
accessible for the user.
- In a place protected by a movement sensor (not
delayed).
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
not recommended recommended
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
not recommended
recommended
- Near a wall-fitted telephone socket and in a place
permitting effective listening of the rooms (without
obstacles and at a height of about 1.5 m).
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
1.50 m
8
3
SECURING
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
- Open the battery compartment with the supplied
key.
- Loosen the two securing screws and remove the
front cover.
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
AP
SUPTEST
2
Insert the cable with the RJ11 plug, taking care
not to crush it.
Cable route
Securing
screws
- Drill the holes in the specified securing points and
secure the support on the wall in the four indicated
points.
Self-protection route
- Connect the RJ11 plug to the control unit via
the supplied pre-wired socket (long side).
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
- Connect the RJ11 plug to the entry-point of
the telephone line via the supplied pre-wired
socket (short side).
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
EFF
- Connect the telephones to the RJ11 socket on
the supplied cable.
- Re-position the cover of the control unit on its wall
support and secure the screw.
9
TEST
AP
ELECTRICAL CONNECTIONS
„ Putting into operation
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
- Fit the batteries, respecting the indicated polarity.
EFF
+
AP
TEST
- +
+
The yellow indicator light “flashes” indicating that the
control unit is in Maintenance Program mode and is
ready to memory-store the control keypad as the first
element.
„ Telephone line connection
RJ11
Refer to the previous section.
Board
RJ11 Plug
Speaker
Cable for telephone
connection
Battery compartment (rear view)
10
- +
-
„ Wiring the outputs
The control unit supplies status and alarm
information.
Cable route
Status: Closed contact: alarm system enabled.
Open contact: alarm system disabled.
Alarm: output of alarm in progress (open collector).
The output, which is normally floating, is earth
connected when the alarm is tripped. Do not exceed
the indicated voltage and current values.
Max voltage: 12Vdc
Max current: 30mA
Closed = Alarm
enabled
Open = Alarm
disabled
11
Earth connected when
an alarm is in progress
Earth
3
PROGRAMMING
GO TO ADD DEVICES MODE
Learning of a MASTER remote-control
When purchased, the control unit is not
programmed.
The MASTER remote-control must be the first
remote-control to be programmed.
In fact, the Master remote-control is essential for
adding any other remote-control.
Time to carry out this operation is limited.
To ensure that the control unit recognises the
system's elements, it must be made to 'learn' them
(registration of the devices).
Procedure
When the control unit is powered up, its indicator
lights flash rapidly and, then, the red indicator lights
flash simultaneously but more slowly. The control unit
is in Maintenance Program mode (the yellow warning
light flashes every second).
-Press the future ON key for 10 seconds: the control
unit beeps once and goes into Add Devices menu.
The yellow operation indicator light comes on with
steady beam.
-Simultaneously press push-buttons 1 and 2 until the
remote-control starts to flash.
-Press the ON Key once:
the control unit beeps once.
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
EFF
+
AP
TEST
- +
+
- +
-
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
EFF
At this point the control unit waits for a control
device to be registered.
TEST
AP
2
ON
BeeP
1
Proceed, using a control keypad or a remotecontrol.
Learning of the control keypad
-Simultaneously press push-buttons 1 and 2, until
the remote-control begins to flash and, then, press
OFF:
the control unit beeps twice.
The keypad must be powered.
- Press OK and, then, using a pointed objective (e.g.
pencil), press the configuration access push-button
located under C key of the keypad.
-Press the ON key twice in succession: the control
unit should emit a confirming beep. The remotecontrol indicator light stays lighted on steady beam
for as long as pressure is exerted.
The yellow indicator light comes on with steady
beam: this means that the control unit is in ADD
DEVICES menu.
-Press the OFF key twice in succession: the control
unit should emit two confirming beeps.
The control unit has registered the master remotecontrol.
C
-
OK
INFO
THE CONTROL UNIT IS IN ADD DEVICES MENU.
The yellow indicator light stays lighted.
+
12
REGISTERING DEVICES
Step 2: put in ADD DEVICES mode.
- press the ON key of the slave remote-control for
about one second,
- press the ON key again (for about 1 second); you
should hear a beep from the control unit.
- press the OFF key of the slave remote-control for
about one second,
- press the OFF key again (for about 1 second); you
should hear two beeps from the control unit.
Note: the control unit must be in MAINTENANCE
PROGRAM mode and in ADD DEVICES menu
(yellow indicator light on steady beam).
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Sensors
Remote-control
Control keypad
Telephone transmitter
Siren
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Control keypad
Peripheral units fault /
Telephone line fault
Passage open signal
EFF
TEST
- Press the OK key and then the configuration
access push-button.
The control keypad beeps once. The control unit
beeps once.
AP
Outdoor siren
Movement detector / Opening detector
- Press the TEST push-button of the siren.
The control unit beeps once.
- Press the detector's TEST push-button.
The control unit sounds a beep and the indicator
light on the detectors' control unit lights up.
The control unit will emit several beep if the
device has not been correctly registered as
regards the radio range limit, or if the maximum
number of elements has been reached.
SLAVE remote-control
The new remote-control will be a slave remotecontrol.
To add a slave remote-control, you have to work in
steps in a limited time period.
„ Exit from the Add Devices mode
When all the elements have been registered:
- press the OFF key of the remote-control or the C
key of the keypad.
The control unit beeps once.
Step 1: synchronise the slave remote-control with
the master remote-control. Bring the two remotecontrols forward, so that they touch.
Close the control unit battery compartment last
of all.
-Simultaneously press push-buttons 1 and 2 on the
master remote-control, and release them when the
indicator light flashes. Press and hold down the ON
key. On the slave remote-control, press the ON key
and release it when the indicator light goes off (after
a double flash, to confirm that a memory-storage
operation has taken place). Release the ON key of
the master remote-control.
If inactive, the control unit will automatically exit from
the ADD DEVICES mode within 5 minutes, and will
remain in MAINTENANCE PROGRAM mode.
-Do likewise for the OFF key
13
DELETING DEVICES
Note: the control unit must be in MAINTENANCE
PROGRAM mode and in ADD DEVICES menu.
This procedure makes it possible to delete the
identity of the devices from the control unit memory:
„ To eliminate all the devices except the outdoor
siren
-
- Press for more than 5 seconds the yellow DELETE
(EFF) push-button of the control unit.
The control unit sounds a long BEEP and the 5
indicator lights flash simultaneously.
The telephone access code is deleted and the
123456 default code is restored.
C
INFO
OK
+
C INFO
+
-
-
+
OK
C INFO
+
-
-
„ To eliminate all devices, including the siren
+
OK
C INFO
OK
-
OK
+
- Press the DELETE push-button for more than 10
seconds.
The telephone access code is deleted (the 123456
default code is restored).
C INFO
+
-
-
Select a device by pressing the relevant TEST
push-button
„ To eliminate one device at a time
C INFO
-Select the DELETE DEVICES menu on the control
keypad and confirm,
OK
-
-Select the device to be eliminated, by pressing keys
+ and - or by directly pressing the TEST push-button
of the device to be eliminated,
OK
+
C INFO
OK
-
OK
+
C INFO
-The identification number and, subsequently, the
name of the device will be shown after confirmation,
OK
-
-Press the OK key until you see the message
PLEASE CONFIRM on the display, and then confirm.
OK
+
C INFO
+
-
-
14
OK
+
OK
+
Select a device with the +
and - push-buttons of the
keypad
AREAS
„ Eliminating devices from an area
The transmission control unit can be used to obtain
selective protection of the rooms, indicated by the
term “AREA”. Only the intrusion detector can be
assigned to an AREA.
The transmission control unit must be
MAINTENANCE PROGRAM mode (door open).
In case of an error, you can eliminate devices,
previously assigned, to a given area of your system.
Procedure:
in
- put the keypad in the CREATION AREA mode;
- confirm to view "XX - - - - -"
- press the yellow push-button of the control unit for
more than 5 seconds
- the control unit beeps briefly to signal that all the
devices of that area were deleted.
„ Assigning devices to an area
Control keypad
- Type in the main access code (1234 by default), by
the navigation keys.
The screen will show
.
Exit from this elimination status is over in 5 minutes.
- Using a pointed object, press the configuration
access push-button once.
- By the navigation keys select INSTALLATION and
then confirm by pressing the OK key.
- Select CREATION menu
Area 1, Area 2, Area 3 or
Area 4, and then confirm.
1
2
3
4
The keypad, and then, the control unit, each beep
once to confirm. The keypad shows “XX -- -- -- -- --”.
- Press the TEST push-button of the detector
assigned to the area.
The screen shows the relevant identity of every
allocated detector.
To access the other areas, press the C key of the
keypad and select the area you require.
- To definitively exit from the menu, press the C key
until the time is shown.
Proceed as indicated above to assign the detectors
to the selected areas.
A device can be associated with several
surveillance areas or none.
An alarm can be enabled in one area at a time.
15
4
CUSTOMISING THE SYSTEM
ACCESS
TO
TRANSMITTER
THE
TELEPHONE
The control unit must be in MAINTENANCE
PROGRAM mode (See Alarm Control Unit
Instructions).
Method 1
Method 1:
From a different telephone line - mobile or fixed type in the number of the system.
The transmission control unit engages the line after
5 to 10 ring tones.
Type in the number of the system from an
external line
"Tuu"
2 secs.
Wait for 5-10 ring tones
The transmitter answers
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
Method 2:
To be used when the transmission control unit coexists with a telephone answering system or other
automatically enabled equipment.
Hello, please type in the access code
Method 2
Type in the number of the system from an
external line
„ Technical block
When you consult the telephone transmitter, a
“Technical block” message will be shown in one of
the following cases:
- the transmitter's identity was deleted by a system,
- the control unit battery compartment is open
(maintenance program mode).
"Tuu"
Wait for 1-2 ring tones
Hang up and wait for 10 seconds
Type in the system's number again
„ Communication block
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
When an alarm is in progress, the telephone call in
progress cannot be blocked (a call from the
transmitter to the outside).
To interrupt the current telephone call cycle, press
the OFF key of a remote-control.
Discharged batteries
Peripheral units fault /
Telephone line fault
The transmitter answers after 1 or 2
ring tones
Passage open signal
Hello, please type in the access code
16
MODIFYING THE SYSTEM PARAMETERS
„ MODIFYING THE TELEPHONE NUMBERS
Call
- access to the customising menu,
- to modify the telephone numbers to be called, press
push-button 1 of the telephone.
1 The transmitter asks you to type in the position
of the telephone number to be modified.
Access code
Customising
Select the function
- press one of the four suggested push-buttons
(choice from 1 to 4) for the position of the telephone
number to be called.
To modify one of the numbers to be called, press 1 or 2
or 3 or 4 or press the asterisk to return to the previous
menu.
from 1 to 4
ess
Pr
If no number has previously been registered in
that position, go directly to step 3.
2 The control unit repeats the registered telephone
number at the selected sequential number. It then
suggests to press 1 to modify it or to press the
asterisk to exit from the function.
- press 1
The third number to be called is: “zero, five, six, three,
two, one, two, two, two, three (05 63 21 22 23)”.
To modify, press 1 or press the asterisk to return to the
previous menu
3 The control unit invites you to type the new
telephone number to be registered.
- type in the telephone number and confirm by
pressing
.
Select to modify
The transmitter asks you to type in the position of
another telephone number to be modified.
Type in the number to be called and press the asterisk.
Repeat the operation for everyone of the 4 telephone
numbers to be typed, or press
to return to the
customising menu, otherwise hang up.
er
g in the num
pin
b
y
T
No telephone number is registered by
default.
The telephone number with sequential position
1 will be the first to be called in case of an
alarm.
Confirm
modification
A space in the numbering is inserted by typing
a # .
The maximum number of digits for a telephone
number is 14.
„ ELIMINATING TELEPHONE NUMBERS TO
BE CALLED
“Type in the telephone number and press the asterisk”
Use the procedure “Modify the telephone
numbers to be called”.
- type in the position of the telephone number to be
eliminated and, after the message “Type in the
telephone number and press the asterisk”, press
only .
Confirm without
typing in
The number has been eliminated.
17
„ HOW TO MODIFY THE VOICE MESSAGE
- access the customising menu,
- press push-button 2 of the telephone.
Call
The transmitter repeats the current voice message
and then invites you to speak after an acoustic
signal, to record the new message.
Access code
Customising
- wait for the beep, and then speak,
Select the function
- confirm by pressing
or wait for the maximum
duration of the message (15 seconds).
You are communicating with your Home Shield.
Record the message after the beep and press the asterisk.
The transmitter will repeat the message.
- press
hang up.
to return to the customising menu or
.
p..
Bee
Hello, you are communicating
with the telephone transmitter
of Mr...
Speak
„ HOW TO MODIFY TIME
Confirm
- access the customising menu,
- press push-button 4 of the telephone.
The transmitter shows the recorded time and then
invites you to type in the 4 digits of the new time.
- type in the four digits.
Call
(e.g.: to type in one and 47 minutes, type in the
following order 0 1 4 7).
Access code
Customising
The transmitter repeats the new time.
- press
hang up.
to return to the customising menu or
Select the function
The time is: “one and forty-seven minutes”:
Type in the four digits of the new time or press the
asterisk to return to the previous menu.
„ HOW TO MODIFY THE DATE
- access the customising menu,
- press push-button 5 of the telephone.
The transmitter shows the recorded date and then
invites you to type in the 6 digits of the new date.
- type in the six digits.
(e.g.: to type in 25 January 2005, type in the following
order 2 5 0 1 0 5).
The transmitter repeats the new date.
- press
hang up.
Call
Access code
Customising
to return to the customising menu or
The date is: twenty fifth of January zero five.
Type in the six digits of the new date, or press the
asterisk to return to the previous menu.
18
CONTROL UNIT INTERNAL
FUNCTIONS
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
„ CONTROL UNIT INTERNAL SIREN
In case of an alarm due to intrusion, the control
unit's internal siren is enabled.
It can be disabled. In that case, make sure that a
warning indicator is present on the system (indoor
and outdoor siren).
TEST
AP
ind
oo
rs
ac
ire
ou
n
sti
c
lev
el
su
pe
r vi
sio
n
pre
-al
arm
be
rad
ep
io
s
sa
tur
ati
tel
on
ep
ho
ne
lin
m
e
fre ono
qu -bi
en
cy
SUP
„ ACOUSTIC LEVEL OF CONFIRMATION
SIGNAL
Every control unit action is signalled by a beep:
- For ON, the acoustic level of the beeps is soft,
- For OFF, the acoustic level of the beeps is loud.
Siren
disabled
ind
oo
rs
ac
ou
sti
c
ire
n
su
lev
pe
el
rvi
sio
n
pre
-al
arm
be
rad
ep
io
s
sa
tur
a
t
tel
ion
ep
ho
ne
m
lin
e
fre ono
qu -bi
en
cy
Siren
enabled
„ DISABLING SUPERVISION
Each element periodically communicates its status
to the control unit. If the control unit does not receive
anything from one of the elements, it signals this
(when the alarm is enabled or disabled) by a set of
beeps.
This supervision can be disabled.
Soft
on
ne
lin
m
e
fre ono
qu -bi
en
cy
tur
ati
n
be
sa
tel
rad
ep
io
ho
sio
arm
-al
rvi
su
pe
sti
ou
ac
pre
n
ev
el
cl
ire
rs
oo
ind
ep
s
Loud
Supervision
enabled
„ PRE-ALARM BEEPS
When an alarm is tripped by a sensor with delayed
enablement (45 seconds), the control unit emits a
set of soft beeps for the entire pre-alarm time. This
reminds the user to disable the alarm. These alerting
beeps can be disabled.
lin
e
m
fre ono
qu -bi
en
cy
ne
ho
sa
ep
dio
tel
rvi
pe
sti
ou
su
ac
tur
ati
o
p sion
bere-a
ep lar
s m
ra
n
ev
el
cl
ire
rs
oo
ind
n
Supervision
disabled
Beeps
enabled
„ RADIO SATURATION CHECK
In the event of simultaneous saturation of the two
frequencies (434 and 868 MHz), for more than 30
seconds, you can select from two options:
ON: outdoor and indoor siren activated (if enabled)
for 90 s, alarm telephone call and signal on the
display of the control keypad.
OFF: only signal on display of the control keypad.
el
ine
m
fre ono
qu -bi
en
cy
r
saadio
tur
a
ph
s
on
on
tio
n
be
ep
n
sio
ar m
tel
e
-al
pre
pe
rvi
cl
su
ac
ind
ou
oo
sti
rs
ire
n
ev
el
s
Beeps
disabled
Acoustic signal
Saturation enabled
lin
o
ne
m
fre ono
qu -bi
en
cy
rat
i
ph
io
sa
tu
be
rad
tel
e
sio
su
pre
-al
rvi
pe
arm
n
ev
el
cl
sti
ac
ou
ind
oo
rs
ire
n
„ TELEPHONE TRANSMITTER
On OFF, the control unit's transmitter is disabled.
ep
e
Acoustic signal
Saturation disabled
Transmitter
enabled
„ MONO-BI FREQUENCY TRANSMISSION
OFF: double frequency always active and alarm
enabled or disabled.
ON: double frequency active only if alarm enabled.
If the alarm is disabled, the system transmits in
mono-frequency (battery saving).
Battery saving
Standard battery
consumption
19
eq oue bi
nc
y
be
rad
ep
io
s
sa
tur
a
tio
tel
n
ep
ho
n
m el
fr on ine
n
sio
arm
-al
pre
rvi
pe
ou
sti
cl
su
ac
ind
oo
rs
ire
n
ev
el
Transmitter
disabled
„ Test of control and information keypad
SYSTEM TEST
- Press the OK key.
The display shows “-- -- -- --”.
The control unit must be in MAINTENANCE
PROGRAM mode
INFO
- Press the
key.
The control unit and keypad emit a beep.
We advise you to run the test so that you can verify after installation - if all the elements of your alarm
system are operating correctly.
For security reasons, the test should be run whenever
a device is added, before a long period of absence
and, in any event, regularly.
C
-
OK
C
INFO
+
-
OK
INFO
+
„ Remote-control test
OK
When the ON or OFF keys of the remote-control are
pressed, this should cause the confirmation signals
to be emitted by the control unit (refer also to the
switch configuration).
INFO
„ Outdoor siren test
While holding down the self-protection contact,
- Press the siren's TEST push-button.
The control unit emits a beep.
„ Detector test
„ Warning signal test
- Press the detector's TEST push-button.
The control unit and detector beep once.
- Press the control unit's TEST push-button.
The detectors are in TEST mode and beep once at
every detection, in the case of movement detectors,
and at every opening of a passage, in the case of
opening detectors.
Everyone of the system's warning signal emits a
brief beep in succession, and then the control unit
beeps once.
Discharged batteries
Peripheral units fault /
Telephone line fault
BeeP
Passage open signal
BeeP
EFF
20
TEST
AP
„ Test for registering the first telephone number
Press for more than 30 seconds the transmission
control unit's TEST push-button. It will call the first
registered number.
„ Test for checking if the transmission control unit
engages the line.
Make a telephone call to a friend or neighbour, with
the phone connected to the control unit's line. While
you remain on the line, ensure that, with the alarm
system enabled, the alarm is tripped, by simulating
an intrusion (e.g. open a door on which an opening
detector is installed).
Make sure that the telephone call was interrupted.
BeeP
„ Test for checking if the external telephone call
is made.
Trip the alarm by simulating an intrusion (e.g. by
passing front of a movement detector).
Inform the recipients on the procedure to follow
when the alarm telephone call begins (refer to
paragraph "How to manage an alarm"), telling them
not to answer the call, in order not to stop the cycle
of telephone calls.
After about ten minutes, contact the persons, to
check if they actually received the alarm telephone
call.
21
5
USE
STATUS DIAGRAM (use with radio control)
MAINTENANCE
PROGRAM
Press the
ON key
for a long time
ADD DEVICES
Press
OFF
Open the battery compartment
(you have 1 minute to do this)
Close the battery
compartment
Press 1 + 2 and
then press the OFF Key
for a long time
(Master only)
ALARM
OFF
If you hear beep signals,
check the events
Press the
OFF key
for a long time
Automatic
System
mode on
Confirmation of
active events
22
Alarm
mode on
Press
OFF
SYSTEM MANAGEMENT IN LOCAL
MODE
„ Alarm cycles / Trip the detection
When the alarm is tripped, the acoustic signal is
enabled for 90 seconds.
It can be stopped by the OFF function of a control
device.
If the fault persists (e.g. a door that stays open), or if
other detections occur, the signal trips a 90 second
cycle four times, with pause intervals of 20
seconds.
If the problem persists at the end of the cycle, the
device which signalled the fault is automatically
excluded and the event - which caused this exclusion
- is registered in the historic record.
When normal conditions are resumed, the exclusion
ceases.
After all the elements have been installed and
programmed correctly, you can put your system into
operation.
„ Alarm OFF Status
To access this mode, press the OFF key of a control
device.
The control unit signals the stop with two beeps.
In this case, the entire system is disabled, but the
control unit continues to receive the supervision and
self-protection information.
„ Alert Detection (emergency call panic button)
The alarm can be tripped also for a help request.
This entails the use of the SOS emergency call panic
button, which trips a “telephone call” type of alarm.
This alarm is also signalled by the control unit by
means of beeps lasting 30 seconds.
„ Alarm Mode on Status
This mode is enabled as soon as you press the ON
function of a control device.
Surveillance, signalled by a beep and indicator light
by the control unit, will be effective on the whole
system after 1 minute.
„ Forced enable
When the alarm system is enabled, if an opening
detector is declared active (open door, etc.), the
control unit sounds several beeps to signal the
"passage open" fault, and will not carry out the
order.
„ Status of Area A1, A2, A3, and A4
To enable the alarm in part of your system, activate
partial protection from the control keypad.
The selected area, and only that area, will be in
effective surveillance conditions.
To make a forced enable possible, press ON again
during the 10 seconds after the first pressure
(this method is identical for all control devices).
In both cases, the control unit beeps once to confirm
that the alarm is enabled.
(important: in this case the opening detector is
inhibited, unless the passage is closed and then
reopened).
The front indicator light of the control unit and an
acoustic signal indicate this change of status.
The remainder of the system stays disabled.
Note: a system in which the general alarm is
enabled, can change over to the area enable status
only after being switched OFF (see the use status
diagram at the side).
„ Disable under threat
This function is used to make a possible aggressor
believe that you are typing in the real access code,
whereas a telephone call is tripped, without any
acoustic signal. To do this, you have to add a unit to
the first digit of your keypad access code and, then
select OFF..
For example: access code “3586” ---> under threat “4586”,
access code “9471” ---> under threat “0471”
„ Technical detection (with a sensor)
A technical alarm - which can be obtained by using a
device known as a “technical sensor” - will be
signalled by several beeps from the control unit, and
the telephone transmitter will make a call.
NOTE: This function is active only on code 1
23
MANAGEMENT BY TELEPHONE
READ THIS BEFORE ANY USE
„ Wait for the end of the phrases before pressing the keys, when carrying out the different
configurations and consultation of the system.
„ The transmitter will automatically disconnect itself if no pressure is exerted for 90 seconds.
„ To return at any time to the main menu, starting off from any function, press key
Likewise, 2 successive pressings of key # enable you to hang up.
of the telephone.
„ Any non-confirmed modification of parameters (no pressure of the indicated push-button, exiting
the function before finishing, etc…) will not be considered.
The old parameters will be maintained (time, date, access code, etc…).
„ How to access the main menu
Starting from a telephone line (fixed or mobile):
- type the telephone number of the line to which the
control unit is connected,
- allow to ring once or twice, then hang up,
- wait for 10 seconds, and then call again within one
minute.
Call
The transmitter engages the line and asks you to
type the access code:
Allow to ring once or twice,
hang up,
wait for 10 seconds.
Call again
Hello, type in the access code
- type in the 6 digits of the access code (1 2 3 4 5 6
by default).
The transmitter communicates the system status,
internal temperature and, later, your main menu.
Access code
Alarm disabled, no signals, indoor temperature is 21
degrees
You can now:
- modify the system's status (ON or OFF),
- listen to what is happening in the rooms where the
transmitter is installed,
- speak so you can be listened to in the protected
rooms,
- customise the transmitter (if the control unit is in
MAINTENANCE PROGRAM mode),
- hang up.
Main menu
To enable the alarm system, press 1,
To listen, press 2,
To speak, press 3,
To customise the transmitter, press 4,
To hang up, press # twice
„ How to confirm reception of an event
Until a given alarm is encountered, it is
communicated to the transmitter at every new
access. To confirm the reception of the alarm:
Main menu,
To delete the alarm, press 0,
To enable the alarm system, press 1,
......
- access to the main menu,
- press the 0 push-button.
You may now hang up.
Delete the alarm
24
„ To listen to the protected rooms
- access the main menu
- press push-button 2 of the telephone
At this point, the transmission control unit allows the
user to listen to what is happening in the rooms, or to
change over to the function “Speak in the protected
rooms”, by pressing push-button 3.
You can listen to what happens in the protected
rooms for a maximum time of 30 sec.
- during the “listen” function, press push-button 3 to
speak or press
to return to the main menu,
otherwise hang up.
Call
Access code
Select function
„ To speak in the protected rooms
- access the main menu,
- press push-button 3 of the telephone.
At this point, the transmission control unit allows the
user to speak in the protected rooms, or to change
over to the function “Listen to the protected rooms”
by pressing push-button 2.
You can speak and be listened to in the protected
rooms for a maximum time of 30 sec.
- during the “speak” function, press push-button 2 to
speak or press
to return to the main menu,
otherwise hang up.
To listen, press two or press
Call
Access code
Select function
To speak, press three or press
When using the “listen” or “speak”
functions, you can change over from one
to the other, by pressing push-button 2 to listen
and push-button 3 to speak (conversation
mode).
"
n…
"lis
t
e
The time available for each function is renewed
(30 seconds), at every pressure of pushbuttons 2 or 3.
k…
"
The transmitter signals the function changes
by emitting the “push-button” tone of the
telephone.
"sp
„ To know the temperature of the rooms
To know the ambient temperature of the room where
the control unit is installed:
- access the main menu: the ambient temperature is
communicated at the end of the first message.
Call
25
Access code
ea
„ Enable or disable the alarm system
- access the main menu,
- press push-button 1 of the telephone
The transmitter shows the main menu, indicating the
system's new status (ON or OFF).
- select another function or hang up.
„ Access the customising menu
Call
Access code
The control unit must be in MAINTENANCE
PROGRAM mode.
- access the main menu,
Select function
- press push-button 4 of the telephone.
CUSTOMISING Menu
The transmitter indicates the customising menu.
- To modify the telephone numbers to be called, press 1,
- To modify the voice message, press 2,
- To modify the access code, press 3,
- To modify the time, press 4,
- To modify the date, press 5,
- To return to the main menu, press
You can now:
- modify the telephone numbers to be called,
- modify the voice message,
- modify the access code,
- modify the time,
- modify the date,
- return to the main menu.
- select one of the suggested functions, or press key
to return to the main menu, otherwise hang up.
ect from 1 to 5
Sel
„ Modify the access code
The control unit must be in MAINTENANCE
PROGRAM mode.
- access the customising menu,
- press push-button 3 of the telephone.
The transmitter indicates the current access code,
then invites you to type in the 6 digits of the new
code.
Call
Access code
Customising
- type the 6 digits of the new code.
The transmitter indicates the new access code.
Select function
- press key
to return to the customising menu,
otherwise hang up.
The access code is:1 2 3 4 5 6.
Type in the 6 digits of the new access code, or
press
ccess co
wa
de
Ne
26
„ How to manage an alarm
Following an alarm, the telephone transmitter calls a
number according to the preset calls cycle.
- the telephone rings, lift the handset.
- press key
.
Lift up the handset
The transmitter announces the welcome message,
and then communicates the alarm, indicating the
time, type (e.g. an intrusion) and the name assigned
to the device which originated the alarm.
Intrusion alarm, press
Confirm that you
have seized the line
You can now:
- listen to the voice message,
- listen to the protected rooms,
- speak in the protected rooms,
- confirm reception of the call.
- Select one of the suggested functions or hang up.
You are communicating with your Home Shield.
At 14.25 hours: office intrusion alarm.
To listen to the voice message, press 1,
To listen, press 2,
To speak, press 3,
To confirm reception of the call, press 4.
If you hang up without confirming
reception of the call (by pressing pushbutton 4), the telephone transmitter calls
the other recorded numbers, continuing
its call cycle.
from 1 t
lect
o4
Se
27
INDICATOR LIGHTS
ADD DEVICES Menu
2 secs.
MAINTENANCE PROGRAM
mode
Alarm memory-stored / In progress
Alarm ON / Alarm OFF
Maintenance Program mode
Detector
Alarm memory-stored / In progress
1
Sabotage memory-stored
2
Sabotage in progress
except control unit
Remote-control
System sabotage alarm
Control and
information keypad
Discharged batteries
Telephone transmitter
Peripheral units fault /
Telephone line fault
Siren
Passage open signal
3
Battery fault in progress
4
Peripheral units fault
or telephone line fault
5
Perimetric fault
EFF
TEST
AP
Status of red indicator lights:
In ADD DEVICES menu
(Yellow operation
indicator light:
)
In AREA CREATION
menu
(Yellow operation
indicator light:
)
A device is present
No devices
A detector is present in the area (X)
No detectors in the area (X)
SIGNALS
If no control device (remote-control or control
keypad) was registered in the system, all
indicator lights flash.
„ Discharged batteries indication
Whenever the alarm system is enabled or disabled,
the control unit emits a series of 3 short beeps.
The time available for replacing the batteries, before
total shut-down of the system, is about 1 month.
To replace batteries, put the control unit in
MAINTENANCE PROGRAM mode.
We advise you to put the discharged batteries in the
appropriate collection bins.
28
„ DELETING THE EVENTS
„ YELLOW OPERATION INDICATOR LIGHT
When you come back, and change over to disabled
alarm mode, the control unit signals (with beeps) if
any alarm events have occurred during your
absence.
- Under normal operation conditions, the indicator
light is OFF.
- When the alarm is enabled or disabled, the
indicator light lights up for two seconds and then
goes OFF.
- After an enable or disable operation, if a fault is
present in the system, the indicator light flashes and
the relevant fault indicator is lighted.
These events can be deleted, i.e. they are no longer
signalled by the control unit (with the exception of the
“discharged batteries” signal).
- In Maintenance Program mode: it flashes (0.1s / 1s).
- In Add Devices menu, it stays on steady beam.
- In Area Creation mode: it flashes (0.5s / 0.5s).
There are two solutions for deleting the events:
With a control device
- Press the OFF key of a remote-control for 10
seconds.
- Then press the INFO key of the control keypad in
order to read the event and, when you have finished,
confirm by pressing the OK key.
The control unit confirms the operation with a beep.
„ FAULT INDICATOR LIGHTS
When the control unit's battery compartment is
opened, the unconfirmed events are shown
automatically.
The red indicator lights indicate the problem in
progress.
Alarm memory-stored / In progress Indicator
light:
This lights up when an intrusion or technical alarm is
stored in the memory. It remains lighted until manual
confirmation by the alarm itself.
Press the “DELETE” pushbutton.
The control unit confirms
the operation with a beep.
Self-protection Indicator light:
It lights up when a system self-protection operation
has been activated (opening or removal of a system
element). It goes OFF following manual alarm
confirmation, but flashes if the fault persists.
With the control unit
- Put the control unit in Maintenance Program mode
(battery compartment open).
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
EFF
TEST
AP
This operation eliminates
all the active events in the
system.
Discharged Batteries Indicator light:
When a status change occurs in the control unit
(enable, disable, etc…), it lights up when the battery
charge of one of the system's elements (except the
remote-control) is insufficient, signalling that the
batteries must be replaced.
The “discharged batteries” event can be deleted only
by replacing the batteries of the device in question.
Supervision Fault
Telephone line fault Indicator light:
It lights up when one of the system's elements
(except the remote-control) stops communicating
with the control unit or does not provide any signal.
It signals a supervision fault on the telephone line.
The control unit indicates the date and records all the
events which occurred in the system.
A deleted event is stored in the events historic record
and is no longer signalled to the user. The historic
record can be consulted in the view mode, using a
control keypad.
Passage Open Indicator light:
It indicates the status of the passages when the
alarm is enabled. It goes off after confirmation of
manual enablement.
29
6
HOW AN ALARM TAKES PLACE
OPERATION OF TELEPHONE CALLS
DURING AN ALARM
„ Events sending
The telephone transmitter element makes calls on
the switched telephone network (STN), according to
the following principle:
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
- a telephone call to recipients according to a preset
cycle (see paragraph telephone calls Cycle). When a
recipient answers, it asks him/her to press a key to
continue listening, and sends a pre-recorded
welcome message.
- indication of the type of event, date and time,
- indication of the suggestions to re-listen to the
welcome message, to listen to the protected room, or
to speak via the transmitter for about thirty seconds.
- event confirmation request, by pressing a key,
- manual disconnection by pressing a series of keys
or automatic.
An alarm
is tripped
The transmitter calls
via the telephone
network, according to
a defined cycle
1st number called
4th number called, if
necessary
„ Telephone calls cycle
Every alarm trips a cycle of telephone calls, which
entails several attempts in sequence, as shown at
the side here.
The telephone call
sequence begins
(following an alarm)
The transmitter exits the cycle as soon as:
- the call reception confirmation code (push-button
4) is received, or when the cycle has been performed
4 times (for numbers 1, 2 and 3) and 3 times (for
number 4), or
- an order was issued (disable or enable) with a
system control device (remote-control or keypad).
telephone call number 1
5 seconds
telephone call number 2
5 seconds
telephone call number 3
5 seconds
telephone call number 4
5 seconds
End of
telephone
calls
sequence
5 seconds 5 seconds
The telephone transmitter holds the line
engaged for the entire duration of the cycle.
30
„ Remote access to telephone transmitter
There are two simple ways of calling the transmitter:
- just type in the number of the line to which you are
connected.
It will answer after 10 ring tones.
This time interval can be adjusted, by typing in the #
81 xx command on the telephone in the main menu.
(xx refers to the number of required tones, which can
vary from 05 to 40).
To use the second way:
- type in the telephone number, wait for one ring
tone, hang up and wait for 10 seconds.
- retype in the number within one minute. The
transmitter will answer after one ring tone.
You are connected to your
Home Shield.
2 secs.
Alarm ON / Alarm OFF
Maintenance Program mode
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
The second method must be used in the
following cases:
- a telephone answering system uses the same
line as the transmitter,
- the subscriber to the line signs a
subscription for a telephone message
service,
The second method is described in the
explanations in the USE chapter.
31
7
ENCLOSURES
TECHNICAL SPECIFICATIONS
- Radio range:
ƒ in free field: from 200 to 300 m, according to
environment
ƒ indoors: according to environment
- Power supply: four 1.5 Volt alkaline batteries
type LR20 (or D)
- Time range:
2.5 years
conditions
under
normal
use
- Functions:
double band system
102 dB integrated siren
historic record of 200 events and
40 ON/OFFs
radio learning
radio codes > 16 million
- Enclosure: ABS
- Dimensions: 284 (L) x 190 (W) x 80 (h) mm
- Operating temperature:
+5°C / +55°C
- Weight (including batteries): 1 Kg
- Connection to telephone network.
Max installation: 40 detectors
14 remote-controls
4 control and information keypads
4 sirens
4 emergency call panic buttons
- Maximum number of main lines (RTCP): 1
- Connection method:
ƒ RJ11 integrated socket
- Selective telephone calls.
- Consumption on stand-by: ~ 320 µA (max 350 µA)
- Average consumption in alarm status: <= 300 mA
- Average consumption in transmission status: <= 50 mA
- 4 telephone numbers (max 14 digits)
- Configuration, events historic record,
parameter consultation by telephone call.
- Self-protection: at opening and removal
- Radio frequency: 434 and 868 MHz band
32
and
CUSTOMISED CONFIGURATION
SUMMARY
To facilitate putting the system into operation, we advise you to do the following:
- write the configuration of your system in the following table (type of detector, location, configuration , etc.),
- identify every detector (with numbers).
Remember that the control and information keypad enables you to assign names, which are already present in
the system's memory.
Protected rooms
Entrance / Hall
Detectors
Type
Identity
Movement
Opening
Corridor
Movement
Opening
Living room
Movement
Opening
Kitchen
Movement
Opening
Bedrooms
Movement
Opening
Garage
Movement
Opening
Timed
YES NO
Quantity
A1
AREAS
A2
A3
A4
Movement
Opening
Movement
Opening
System parametering memo
TRANSMISSION CONTROL UNIT
OPENING DETECTOR
1 : Indoor siren (OFF enabled)
2 : Siren confirmation acoustic level (OFF
loud)
3 : Control unit supervision (ON enabled)
4 : Pre-alarm acoustic signals (ON enabled)
5 : Radio 'dazzling' (ON enabled)
6 : Transmitter (ON enabled)
7 : Mono-bi frequency transmission (OFF bifrequency)
1 : Detector / Transmitter (OFF / ON)
2 : Immediate / Delayed (OFF / ON)
3 : NC / NO (OFF / ON)
MOVEMENT DETECTOR
R
1 : Immediate / Delayed (OFF / ON)
OFF
33
I
GLOSSARY
Alarm
- Dissuasion acoustic signal, emitted by a siren, when intrusion occurs
- Status of system when an intrusion occurs.
- Common name for an alarm system.
Area
A set of devices which operate at the same time, associated with partial enablement
of the system.
Range
The average life of a device's batteries, under normal use conditions.
Self-protection
Also defined as self-surveillance. It is the function that surveys the system round-theclock against any sabotage act. Irrespective of whether the control unit is enabled or
disabled, if one of the system's elements is opened, or if the control unit is detached
from its support, the siren is immediately tripped.
To Delete, Deleting
procedure
To acknowledge any information issued by the system, and eliminate it.
Transmitter
A transmitter makes it possible to signal an alarm by telephone, thanks to a voice
message.
Confirmation
An acoustic signal from the control unit indicating modifications to the ON / OFF status
and correct reception of the radio transmissions during the tests.
Parameter
Used for defining the type of signal (sirens, …).
Radio Range
The distance at which a device in a radio system (remote-control, detector, siren,
transmitter, etc.) is able to dialogue with another radio device, without any problems
of understanding the exchanged data.
Reading request
Reporting with attenuated acoustic signals and flashing indicator lights, prompting the
user - when the alarm is disabled - to read the event stored in the control unit's
memory.
Signal, signalling
The function performed by the control unit after every alarm detection in the installed
system. This signal can be acoustic (siren), telephone (transmitter), or electric
(command of electric equipment, to simulate a presence in a protected room).
Supervision
Surveillance by the control unit of all the sensitive elements in your system to detect
any trouble, fault or malfunction of the system in protecting the rooms (e.g. sabotage
of protective or signalling elements).
Universal transmitter
The magnetic opening contact can be used for connecting any released contact
(configurable by dip-switches). It thus becomes a universal transmitter.
34
CE DECLARATION
R&TTE DECLARATION OF CONFORMITY
Effective use of the radioelectric spectrum:
EN 300-220_3 V1.1.1(September 2000)
EN 300-220_1 V1.3.1(September 2000) Chapter 9.3.3
Name: H4 Alarm Control unit with siren and telephone transmitter
Distributor: FAAC S.p.A.
Via Benini, 1 - 40069 Zola Predosa - Bologna (Italy)
It is declared that the essential radio tests were performed
Type: Transmitter - Receiver
The CE mark is affixed to the product
It is declared that the above mentioned product conforms to the
essential requirements of directive R&TTE 1999/5/EC
Year when CE mark was affixed: 2003
Manufacturer's CE Declaration: No. 02-035_1
Electrical safety:
NF EN 60950 (October 2000)
Bologna, 18/01/05
The Managing Director
A. Bassi
Electromagnetic compatibility:
EN 301489_3 (July 2000)
NF EN 50130_4 (April 1995) + A1 (1998)
35
FAAC S.p.A.
Via Benini, 1
40069 Zola Predosa (BO) - ITALY
Tel.: 051/61724 - Fax: 051/758518
www.faacgroup.com
Distributor's Stamp:
The descriptions and illustrations in this manual are not binding. While leaving the essential characteristics of the
equipment unaltered, FAAC reserves the right, at any time and without having to update this publication, to make
the modifications which it considers convenient for technical improvements or for any other construction or
commercial requirements.