Product brochure
Eaton FlexPDU and Maintenance Bypass PDU
Eaton provides five different functions for rack power
distribution solutions. Two of these functions, FlexPDU
and Maintenances Bypass PDU, were created as
accessories specific to some of our UPSs. Both of
these units offer the flexibility of connections to
meet the demanding requirements of today’s data
center architects.
The HotSwap Maintenance Bypass (MBP) unit enables
easy UPS replacement without interruption of the load.
The HotSwap MBP is ideal when exchanging a unit or
servicing a UPS. For added convenience, the HotSwap
MBP offers two types of receptacles: 5-15R or 5-20R.
Features
• H
otSwap MBP provides service continuity during
UPS maintenance or upgrade
• Both units offer connections to all types of equipment
• Eases installation with flexible mounting options
• Minimal depth accommodates most space
constraints
The FlexPDU is a basic function power distribution
unit with a short power cord for easy, close mounting.
FlexPDUs are available with 5-15R, 5-20R or L5-20R
output receptacles, for connection to a wide range
of equipment.
Both of these options allow for easy deployment, even
in space-constrained environments. You have a variety
of mounting options, including top and side mounting.
Side mounting Flex PDU
with Tower UPS
HotSwap MBPs rackmounted
horizontally in rack
Top mounting horizontal
FlexPDU with 2U UPS
Top mounting vertical
FlexPDU
FLEXPDU MODELS
Style Number
Input Plug
Breaker
Max kW
Function
Cord (ft)
Orientation
Receptacles
Dimensions
(H x W x D, in)
EFLXL1500R-PDU1U
58015
5-15P
None
1.44
BA
3
1U
(12) 5-15R
1.7 x 19.0 x 2.4
EFLXL2000R-PDU1U
58020
5-20P
None
1.92
BA
3
1U
(12) 5-20R
1.7 x 19.0 x 2.4
EFLXL2000R-PDU1UL
58021
5-20P
None
1.92
BA
3
1U
(5) L5-20R
1.7 x 19.0 x 3.0
EFLXI3000R-PDU1UIEC
68438
C20 Inlet
(2) 20A
3.33
BA
3
1U
(12) C13, (1) C19
1.7 x 19.0 x 2.4
Catalog number
EHBPL1500R-PDU1U
Style Number
58115
Input Plug
5-15P
Breaker
None
Max kW
1.44
Function
BA
Cord (ft)
8
Orientation
2U
Receptacles
(6) 5-15R
Dimensions
(H x W x D, in)
2.1 x 17.3 x 3.8
EHBPL2000R-PDU1U
58120
5-20P
None
1.92
BA
8
2U
(6) 5-20R
2.1 x 17.3 x 3.8
EHBPL3000R-PDU1U
58130
L5-30P
(2) 20A
2.88
BA
3.3
2U
(5) 5-20R
2.1 x 17.3 x 3.8
Catalog number
HOTSWAP MODELS
COMPATIBILITY MATRIX FOR RACKMOUNT UPSs*
FlexPDU
plug/amp rating
15A
20A
UPS model
(North American only)
Eaton 5P 1U UPS, 550, 750, 1000 and 1500 VA
Eaton 5P 2U UPS, 1500, 2200 and 3000 VA
Eaton 5) 2U Compact UPS, 750, 1000 and 1500 VA
Eaton 5PX UPS, 1000 and 1500 VA
Eaton 9PX UPS, 700, 1000 and 1500 VA
Eaton 5PX UPS, 2200 VA
Eaton 9PX UPS, 2000 VA
Rack mounting
3
3
3
3
3
3
3
*For tower models, all FlexPDUs can be wall-mounted. ** Rear mounting available on 3U models only.
HotSwap MBP
plug/amp rating
15A
20A
30A
UPS model
(North American only)
Eaton 5P UPS, 550, 750, 1000 and 1500 VA
Eaton 5P 2U UPS, 1500, 2200 and 3000 VA
Eaton 5P 2U Compact UPS, 750, 1000 and 1500 VA
Eaton 5PX UPS, 1000 and 1500 VA
Eaton 9PX UPS, 700, 1000 and 1500 VA
Eaton 5PX UPS, 2200 VA
Eaton 9PX UPS, 2000 VA
Eaton 5PX UPS, 3000 VA
Eaton 9PX UPS, 3000 VA
Rack mounting
3
3
3
3
3
3
3
3
3
*For tower models, all HotSwap MBPs can be wall-mounted. **Rear mounting available on 3U models only.
To interact with the FlexPDU and Maintenance
Bypass PDF, please visit: Eaton.com/epdu
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
©2017 Eaton
All Rights Reserved
Printed in USA
Publication No. PDU17FXA / GG
August 2017
Eaton is a registered trademark.
All other trademarks are property
of their respective owners.
Follow us on social media to get the
latest product and support information.