Technical
training
Purpose:
The purpose of this instruction is to inform you about the new
commercial and technical aspects of the ComBi-line.
ComBi-line
Possible executions:
CB 2x5
CB 2x5W
CB 2x10
CB 2x10W
CB 2x20
CB 2x20W
CB 2x40 (new 2006)
CB 1x5 L/R
CB 1x5W L/R
CB 1x10 L/R
CB 1x10W L/R
CB 1x20 L/R
CB 1x20W L/R
CB 1x40 L/R (new 2006)
(Combination of L & R)
ComBi-line
Possible executions:
CB 5
CB 10
CB 20
CB 40 (new 2006)
CB 5W
CB 10W
CB 20W
CB 10W
ComBi-line
Accessories:
Wall brackets for wall mounting
Base plate heightening, to increase
the tap height to 335 mm
ComBi-line
Accessories:
Open base stainless steel
with height adjustable drip tray holder
Combine a left and right machine to
increase the capacity
(old FC GL Duplo)
ComBi-line
Bigger volumes of
hot water needed?
Use our new water boiler WKT-D with a
capacity up to 32 litres/hour.
Attention: Don’t use wall note of CB
column a separate electrical connection
is required.
Denmark & Switzerland;
available with reduced power 2200W,
22 litres/hour.
Available in quantities 5, 10 and 20
litre, and manual filled (HA) en with
water connection (VA).
ComBi-line – technical data.
Hour capacity coffee system
•
•
•
•
CB
CB
CB
CB
5 (W)
10 (W)
20 (W)
40
30 liter/h
60 liter/h
90 liter/h
180 liter/h
Hour capacity hot water system: 2200W
• CB 5 (W)
• CB 10 (W)
• CB 20 (W)
22 liter/h
22 liter/h
22 liter/h
Buffer stock 2,2 liter
Buffer stock 3,6 liter
Buffer stock 3,6 liter
ComBi-line – technical data.
Electrical connection
1N~ 220-240V 50-60Hz (CB 5)
3N~ 380-415V 50-60Hz (other)
More over price:
CB 5W with priority circuit: 1N~ 220-240V 3200W
Electrical execution 3~ 220-240V ; easy to realise
(information sticker inside left panel)
Attention Denmark and Switzerland (max. 10A/~230V):
Order CB 2x5 into 3N~400V (Animo standard = 1N~230V 3200W)
Tip: CB 2x10W with priority circuit <10A per phase!
Container: CNe/CNi
Two executions:
CNe (electrical execution)
CNi (insulated execution)
Deliverable in 4 capacities: 5, 10, 20 and 40 Liter
Content:
5
10 20
40
Content max.:
5,5 11 22
44 liter (= +10%)
Double walled st/st
Container: CNe/CNi
Advantages containers CNe / CNi
•
•
•
•
•
Standard supplied with insulated lid: safety
Integrated gauge glass (with an extra glass in
protector)
No hot-spots
Removable connection cable (CNe), 1,5m with
plug : convenience, safety
Socket with splash protection
Containers: CNe/CNi
Other features
•
•
•
•
Synthetic grips
Tap with quick connector
Magnet for container in position;
Gauge glass, easy to remove and clean
Surcharge for
• Extra no-drip tap at the back (with/without gauge
glass)
• Tap protection
• Clip fastener for lid
Containers: CNe/CNi
Accessories
•
•
•
•
Coffee blender/ transport disk
Tea filter and disk
Filling pipe
Gauge glass brush
CNe – heating
• Direct foil heating on the
bottom of the container
• No hot-spots !
• Holding temp. 80-85°C
Container
CNe 5
CNe 10
CNe 20
CNe 40
Diam.
12cm
15cm
15cm
15cm
Power
35W
70W
70W
2x70W
Heat transmit 0,4 W/cm2
This means no Hot Spots !
CNi
• Insulation = equal to the present containers
• Temperature loss = equal to the present containers.
CNi 5
abt. 4°C/hour
CNi 10
abt. 3°C/hour
CNi 20
abt. 2,5°C/hour
• Dish washer proof (IP65)
• Magnet for container in position
Synthetic filter
Advantages
• weight saving (empty) = ca. 50%
5
10
20
•
•
•
•
synthetic
704 gr
1288 gr
1656 gr
stainless steel
1378 gr
2678 gr
3682 gr
Minimum loss of heat; better for the coffee
Cool wall; safety
No (separate) inlay; user convenience
Attention ; CB 2x40 has stainless steel filters.
Synthetic filter
More features
• Dish washer proof
Material: Polypropylene >PP<
• Integrated grips
• Double walled (no hot outside): safety
• St/st spray head in synthetic lid
for an even and complete saturation of the coffee bed
• Filter paper: 5
10
20
101/317 (= equal to DE 5)
152/457 (= equal to DE 10)
203/533 (= equal to DE 20)
• Coffee advise: standard grinding
i.c.w. interval brew fine grinding possible
ComBi-line – First time use
• Installation is almost equal to FC GL
• During the 1st installation, you should
make the following settings in the
operator menu:
- Language (default = English)
- Time
- Date
- Descaling indicator coffee system
- Coffee dosing
- Descaling indicator hot water system
ComBi-line – user front panel
Brew selection (4x)
3= Start + confirm operator
2= (Emergency) Stop
cancel button menu
On/off button Hot
water system
menu
Timer function (delayed
brewing process)
On/off container heating
ComBi-line –display symbols
4 pre-programmed brew
quantities (= equal GL)
Swivel arm position
Container position
Container heating
Hot water system ‘On’
Tap symbol or actual temp.
Actual time indication
(1)
ComBi-line – display symbols
filter dripping out
(2)
container not placed (correctly)
timer activated
descale signal
swivel arm out of position during coffee
brewing
swivel arm not in position
3 = press START to continue
2 = process is canceled press STOP
ComBi-line – coffee brewing
• 4 pre-select brew buttons for quick select
• Coffee dosing advice in display
• Automatic container heating on when brewing
starts
• Dosed water volume during brewing in display
• Beep signal (1x short) after hot water dosing
stops
• Beep signal (3x short) after filter has dripped
out
• Beep signal + warning symbols after bad
position swivel arm and container
• Interval brew (can be activated in operator
menu)
• Demonstration + explanation user menu
ComBi-line – extended start time
• Easy to activate (easy to de-activate, just
press stop)
• Coffee and/or hot water system can be
selected
• Maximum extended starting time:
6 days (long weekend is no problem)
• Just select wanted brew quantity; and
activate with 3
• 5 minutes before starting brew container
pre-heats
• During timer activation it is possible to keep
the second container heating switched on.
• All safeties are kept during activated timer
• No loss of timer setting by power cut off!
• Demonstration + explanation timer
ComBi-line – switch on boiler
• Push on/off button hot water system
(tap symbol)
• Blinking tap or temperature symbol:
water is not at the correct temperature
• Standard hot water temperature: 90°C
(adjustable 60-97°C)
• Extra 97+°C setting; after boiler reached
97°C, 1 heating element heats a extra period
of time improving the tea water quality.
• The boiler refill and heat in charges of 0,75
liter, for faster boiler recovery after complete
draw-off.
• All temperature features can be set in the
operator menu
ComBi-line – operator menu
• For trained personal; operators
and/or end users
• Activation only after entering PIN
code, printed inside manual.
• All menu items are numbered for
easy navigation
• Demonstration + explanation
operator menu
ComBi-line – service menu
• Only for trained service personal; service
engineers only
• Activation only after entering service PIN
code. List is printed in service manual &
printed on sticker inside left panel.
• All menu items are numbered for easy
navigation
• Service menu = operator menu + extra
service menu items
• Demonstration + explanation service menu
43233
ComBi-line – descaling
Coffee system / Hot Water system
•
•
•
•
•
•
Operator menu gives information how close
both systems are from the de-scale signal.
After the de-scale indication symbol (tool
symbol) lights up one of the systems has to
be de-scaled. In the operator menu can be
read which system has to be de-scaled.
Descaling program activated in the operator
menu.
The user can follow the instructions on the
display and the descaling instructions in the
manual.
Safety; the user must walk trough the
complete program.
De-scaler solution can not stay behind, even
when user switches the machine off, the
program stays active.
When de-scaling program is activated in the
service menu, the program can be canceled at
any moment.
Figure: Descaling of the coffee system
ComBi-line – descaling
2 litre descaling
solution
(abt. 60°C) slowly
poured in by hand
Descaling funnel
Advice; Animo de-scaling
(powder) solution
Flow diagram showing how the de-scaling
solution runs though the flow heating system
Water column only
No heating!
ComBi-line – descaling
2 litre de-scaling
solution
(abt. 60°C) slowly
poured in by hand
Descaling funnel
Advice; Animo de-scaling
(powder) solution
Flow diagram showing how the de-scaling
solution enters the boiler system
ComBi-line - water treatment
We recommends water treatment when hardness is >10°kH
New in program; Brita AquaQuell® Purity
• Unique BRITA 4 stage filtration (down to 10 micron)
• Pre-filter – AquaQuell filter medium – activated carbon – fine filter
• Flexible replacement cartridges
AquaQuell® Purity
Type
Capacities
300
4.217 litres (10°kH)
600
7.200 litres
1200 13.000 litres
Complete set contains;
• pressure container lid with display unit
• pressure container
• cartridge Purity
ComBi-line – coffee system
A
•
A=
B=
C=
D=
E=
F=
G=
•
SOFT START
flow heater starts-up in 2 phase
(reduced start-up power)
B
C
Maximum electrodes
Mass electrode
Minimum electrodes
Flow meter
Inlet valve
Flow heater
Heating element
D
G
E
F
ComBi-line – hot water system
A
•
A = maximum electrode
B = minimum electrode
C = mass electrode (2x!)
D = inlet valve
E = NTC-sensor
F & G = heating element
•
Charge (0,75 liter)
filling/heating system
C
CB5W fills/heat 3x, total heat time 14 min.
CB10W fills/heat 5x, total heat time 20 min.
B
C
CB20W fills/heat 5x, total heat time 20 min.
E
D
F
G
ComBi-line – Faults
ERROR messages in display
C codes for errors inside the coffee system
B codes for errors inside the hot water system
- Error list in user manual
- Extended error list in service manual
- The service menu has a log menu where the last 15 error history
can be displayed.
ComBi-line - Trouble shooting
C2 (coffee)
C3 (coffee)
C4 (coffee)
C7 (coffee)
C8 (coffee)
C9 (coffee)
Flow heater is on for more than twenty minutes
Min. electrode fault; The min. electrode is not reached during
the coffee making.
Filling time fault; The max. electrode is not reached within 40
seconds of the coffee maker starting.
Solenoid valve fault; Flow meter registers water flow while the
inlet valve is electrically closed.
Minimum electrode fault; Min. electrode doesn't see any water,
max. electrode does.
Filling time fault; error C3 changes to Error C8 after 3 minutes.
Coffee maker inlet valve closes.
Flow meter fault; inlet valve is electrically opened, but the flow
meter doesn't register any water flow
ComBi-line - Trouble shooting
B0 (boiler)
B1 (boiler)
B2 (boiler)
B3 (boiler)
B7 (boiler)
B8 (boiler)
E0
E1
Temperature fault; NTC sensor registers a temperature
higher than 108°C
Temperature fault; NTC sensor registers a temperature
lower than 0°C
The heating element is on for more than twenty minutes.
Filling time fault; The max. electrode is not reached within
120 seconds of the hot water system being switched on.
Minimum electrode fault; Min. electrode doesn't see any
water, max. electrode does.
Filling time fault; error B3 changes to Error B8 after
approx. 10 minutes. Hot water system inlet valve closes.
No NTC sensor is detected
NTC sensor is closed short-circuited
3N~400V
~230V
Sensor circuit
Heating circuit
~230V circuit
Fuse 1,6A, wall notes only
Fuse 4 A (slow)
Valves & wall notes
Next to left wall note
Fuse 315mA (slow)
Power supply PC board
On board power supply
Input AC 90-250V / Outputs DC 5, 12, 24V
PC board heating circuit
I/0 board
Main PC board
Heating
Dry-boil safety
24Vdc circuit
3N~400V circuit
PC board sensors circuit
Flowmeter
Container / swivel arm reed sensors
3N~400V connection
The machine electrically ‘easy’ to modify
in star, triangle or single phase
By activating the priority function, it is
possible to connect a CB2x5W (normally
3 phase connection) on 1 phase 230V.
Attention; does not function in DK and
CH
The priority function switch off the boiler
during the coffee brewing process.
Power & current overview
CB
Model
Power supply
(50-60Hz)
Power
Coffee system
Power
Boiler system
Power
Tot
Current
/phase
Fuse
Cable
H 05 VV-F
Cable
article number
Model
Voedingsspanning
(50-60Hz)
Vermogen
Koffiezetgedeelte
Vermogen
heetwatergedeel
te
Totaal
vermoge
n
Stroom
per fase
Afzekering
Kabel
H 05 VV-F
Kabel
artikelnummer
V
kW
kW
kW
A
A
mm2
CB5
CB10
CB20
1
N~
230
3,0
-
3,2
13,9
16
3 x 1,5
02178
1
N~
240
3,3
-
3,5
14,6
16
3 x 1,5
02178
3
N~
400
3,0
-
3,2
4,6
10
5 x 1,5
02196
3
N~
415
3,3
-
3,5
4,9
10
5 x 1,5
02196
3
~
440
3,0
-
3,2
4,2
10
4 x 1,5
02196
1
N~
230
6,0
-
6,2
27,0
32
3x4
02253
1
N~
240
6,5
-
6,7
27,9
32
3x4
02253
3
N~
400
6,0
-
6,2
9,0
10
5 x 1,5
02196
3
N~
415
6,6
-
6,8
9,5
10
5 x 1,5
02196
3
~
440
6,0
-
6,2
8,1
10
4 x 1,5
02196
1
N~
230
9,0
-
9,2
40,0
50
3x4
02253
3
~
230
9,0
-
9,2
23,1
25
4 x 2,5
02236
3
N~
400
9,0
-
9,2
13,3
16
5 x 2,5
02236
3
N~
415
9,8
-
10,0
13,9
16
5 x 2,5
02236
3
~
440
9,0
-
9,2
12,1
16
4 x 2,5
02236
Model
Power supply
(50-60Hz)
Power
Coffee system
Power
Boiler system
Power
Tot
Current /
phase
Fuse
Cable
H 05 VV-F
Cable
article number
Model
Voedingsspanning
(50-60Hz)
Vermogen
Koffiezetgedeelte
Vermogen
heetwatergedeelte
Totaal
vermogen
Stroom
per fase
Afzekering
Kabel
H 05 VV-F
Kabel
artikelnummer
V
kW
kW
kW
A
A
mm2
CB- W
Power & current overview
CB5 W
CB10 W
CB20 W
1
N~
230
3,0
2,2
5,4
23,5
25
3 x 1,5
02178
1
N~
240
3,3
2,4
5,9
24,6
25
3 x 1,5
02178
1
N~
230
3,0
2,2
3,2
13,9
16
3 x 1,5
02178
3
~
230
3,0
2,2
5,4
15,8
16
4 x 1,5
02196
3
N~
400
3,0
2,2
5,4
7,5
10
5 x 1,5
02196
3
N~
415
3,3
2,4
5,9
7,9
10
5 x 1,5
02196
3
~
440
3,0
2,7
5,9
9,2
16
4 x 1,5
02196
1
N~
230
6,0
2,2
8,4
36,5
40
3x4
02253
1
N~
240
6,5
2,4
9,1
37,9
40
3x4
02253
1
N~
230
6,0
2,2
6,2
27,0
32
3x4
02253
3
~
230
6,0
2,2
8,4
23,4
25
4 x 2,5
02236
3
N~
400
6,0
2,2
8,4
11,8
16
5 x 1,5
02196
3
N~
415
6,6
2,4
9,2
12,5
16
5 x 1,5
02196
3
~
440
6,0
2,7
8,9
13,2
16
4 x 1,5
02196
1
N~
230
9,0
2,2
9,2
40,0
-
4x4
02253
3
~
230
9,0
2,2
11,4
30,9
32
4x4
02253
3
N~
400
9,0
2,2
11,4
16,2
25
5 x 2,5
02236
3
N~
415
9,8
2,4
12,4
17,0
25
5 x 2,5
02236
3
~
440
9,0
2,7
11,9
17,1
25
4 x 2,5
02236
#
#
#
Water reservoir
Lid
- de-scale openings
- sensor holders swivel arm detection
- coffee system level probes
- hot water system level probes
Reservoir
- integrated water inlets
- integrated overflow
- left; water reservoir coffee system
- right; water reservoir hot water system
Level probes
• Sensitivity level probes
Min. Mass Max.
- CB
12 µS
82 kΩ
- FC GL standard
sensitive
50 µS
10 µS
20 kΩ
100 kΩ
µS = micro Siemens
Display interface
Membrane panel
Contrast Display
Left-turn = darker
Right-turn= lighter
Flat cable to PC board
PC board & display interface
New PC board includes:
• Fuses
• Battery (not activated)
Attention; exclusive EPROM
must be ordered separately
Membrane
panel
Eprom
Display
ComBi-line - look inside
ComBi-line - look inside
ComBi-line - look inside
ComBi-line - Opening top
ComBi-line Maritime
ComBi-line 40 litre model
New in 2006….
CB 2x40, CB 1x40 L-R, CB 40, no W models!
Column CB40
• 2x 9kW flow heater (new type), incl. Soft start!
• New inlet valve 4 ltr/min
• 2x relay 02013 (each heater 1 relay, (I/O board
is not used).
• Model settings already in Eprom SW1.5b
(1O 05494) (today's version)
Container CN40e
• 2x70W foil heaters.
• Socket with splash protection.
• ‘old’ Stainless steel grips en filters
ComBi-line – CB40 look inside
ComBi-line – CB40 heating circuit
Modifications
Modification / Change
Fuse 4A SLOW (03224) is
changed into fuse 1,6A QUICK
(03247)
New: 1,6A Quick
02347
From machine No.
1O 03828
Reason
Selective fusing
Interchange ability
Fuse is interchangeable
03224
Existing: 4A slow
Modifications
Modification / Change
Spare parts (PC boards)
From machine No.
Medio Juli 2005
Reason
Mentioned parts are specially packet (inclusive
documentation) for EMC safe transport for
single spare part sales
Interchange ability
PC board PP34a CB+OV (12 relays) can be used
in ComBi-line as well in OptiVend machines.
The ComBi-line exploded views (SPI’s) are
modified.
Modifications
Modification / Change
Tube connection water reservoir CB-W.
From machine No.
1P 03369
Reason
To prevent air bubbles blocking the flow
Interchange ability
The new designed coupling fits into the
existing hole of the hot water tank
The ComBi-line exploded views (SPI’s) are
modified. See also the attachment.
New
Old
Modifications
Modification / Change
EPROM ComBi-line
From machine No.
1O 05494 (beginning 2005 !)
From V1.5b is model CB40
inside the software
Reason
Introduction CB 2x40
Interchange ability
Eproms with software V1.5b and higher are
incl. CB 2x40 model settings.
Service manual is also modified!
(also include the CB 2x40)
8
ð
1
2
3
4
Model CB5
Model CB10
Model CB20
Model CB40
Model E
Service menu: Load defaults
Modifications
Modification / Change
Left side funnel hole for de-scaling purposes
Reason
The funnel pipe is now better guided
towards the drain hole in the bottom of the
reservoir by special ribs.
This guiding is already inside the reservoir
for one year. Only the drain hole is recently
changed so the funnel pipe is falls deeper
inside.
Interchange ability
The reservoir can normally interchanged
when needed.
• Questions?
Thanks for your attention !
Marcel Tempelman