IP-EL Series - User's Manual
PTZ
Control
Motion
Activated
Recording
Guaranteed
Warranty
View From
Anywhere
4K
Resolution
Welcome
Thank you for purchasing our IP camera!
This user’s manual is designed to be a reference tool for your system.
Please read the following safeguard and warnings carefully before you use this series product! Please keep
this user’s manual well for future reference!
Our units do not support PAL
Important!
To find your cameras on the network, use the "config Tool" found in the
CD(under Software>ConfigTool) that came with your package. Some
cameras will be assigned as a DHCP. Therehore, The "IP Config Tool is
required to find the camera on the network.
DO NOT Connect all the cameras on the same network at the same time.
This will cause IP conflict within your network and you will not be able to
accress your cameras. Before connecting all the of the IP cameras on the
network One-At-A-Time.
DO NOT power the camera with both PoE and a power supply at the
same time.
If you purchase a PoE(Power Over Ethernet) device from us, Whether
as an External POE Switch or built into on of our NVRs, your camera
will be powered through the Ethernet cable and will not need to power it
with a seperate power supply.
*Restrictions may apply*
Important Safeguards and Warnings
1.Electrical safety
All installation and operation here should conform to your local electrical safety codes.
The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited
power source is rated 12V DC in the IEC60950-1.This series product supports PoE too. Please note:
Do not connect these two power supplying sources to the device at the same time; it may result
in device damage!
We assume no liability or responsibility for all the fires or electrical shock caused by improper handling
or installation.
We are not liable for any problems caused by unauthorized modification or attempted repair.
2.Transportation security
Heavy stress, violent vibration or water splash are not allowed during transportation, storage and
installation.
3.Installation
Do not apply power to the camera before completing installation.
Please install the proper power cut-off device during the installation connection.
Always follow the instruction guide the manufacturer recommended.
4.Qualified engineers needed
All the examination and repair work should be done by the qualified service engineers.
We are not liable for any problems caused by unauthorized modifications or attempted repair.
5.Environment
This series IP camera should be installed in a cool, dry place away from direct sunlight, inflammable,
explosive substances and etc.
Please keep it away from the electromagnetic radiation object and environment.
Please make sure the CCD (CMOS) component is out of the radiation of the laser beam device.
Otherwise it may result in CCD (CMOS) optical component damage.
Please keep the sound ventilation.
Do not allow the water and other liquid falling into the camera.
Thunder-proof device is recommended to be adopted to better prevent thunder.
The grounding studs of the product are recommended to be grounded to further enhance the reliability
of the camera.
6. Daily Maintenance
Please shut down the device and then unplug the power cable before you begin daily maintenance
work.
Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens
surface.
Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to
dilute the mild detergent first and then use it to clean the device. Finally use the dry cloth to clean the
device.
Please put the dustproof cap to protect the CCD (CMOS) component when you do not use the camera.
7. Accessories
Be sure to use all the accessories recommended by manufacturer.
Before installation, please open the package and check all the components are included.
Contact your local retailer ASAP if something is broken in your package.
Accessory Name
Amount
IP Camera Unit
1
CD
1
Installation Accessories Bag
1
Table of Contents
1
2
4
5
General Introduction ..................................................................................................................
1.1
Overview........................................................................................................................
1.2
Features.........................................................................................................................
1.3
Camera Installation.......................................................................................................
1.4
Varifocal lens...................................................................................................................
Structure ......................................................................................................................................
2.1
Multiple-function Combination Cable ........................................................................
2.2
Framework and Dimension.........................................................................................
Quick Configuration Tool...........................................................................................................
4.1
Overview.........................................................................................................................
4.2
Operation.......................................................................................................................
FAQ .............................................................................................................................................
Appendix Toxic or Hazardous Materials or Elements ................................................................
1 General Introduction
1.1 Overview
This series IP camera integrates the traditional camera and network video technology. It adopts video
data collection, transmission together. It can connect to the network directly without any auxiliary
device.
This series IPC uses standard H.264 video compression technology, which maximally guarantees the
video quality.
It supports the IR night vision function. In the night environments, the device can use the IR light to
highlight the object which is suitable for the surveillance function in the low illumination environments.
The waterproof design conforms to the IP 66 level. It has the sound waterproof function suitable for
use in the outdoor environments.
It can be used alone or used in a network area. When it is used lonely, you can connect it to the
network and then use a network client-end. Due to its multiple functions and various uses, this
series IPC is widely used in many environments such as an office, bank, road monitor and etc.
1.2 Features
User
Management
z
z
Support central server backup function in accordance with your configuration
and setup in alarm or schedule setting
z Support record via Web and the recorded file are storage in the client-end
PC.
z Support network storage function such as FTP.
z IPC supports one-channel video data transmit to network terminal and then
decode. Delaying time is within 270ms (network bandwidth support needed)
z Max supports 20 connections.
z Adopt the following video transmission protocol: HTTP, TCP, UDP,
MULTICAST, RTP/RTCP, RTSP and etc.
z Support web access.
z Realize IPC configuration and management via Ethernet.
z Support device management via web or client-end.
z External power adapter DC 12V.
z Support PoE.
Warning!
Do not connect these two power supplying sources to the device at the
same time; it may result in device damage!
z Log function
z Support system resource information and running status real-time display.
z Day/Night mode auto switch.
z Support picture parameter setup such as electronic shutter and gain setup.
z Support motion detect.
z Backlight compensation: screen auto split to realize backlight compensation
to adjust the bright.
z Support video watermark function to avoid vicious video modification.
z Built-in IR light. Support IR night vision.
z The enclosure conforms to the IP 66 protection. Has the waterproof function.
z
Storage
Function
Network
Monitor
Network
Management
Power
Assistant
Function
Different user rights for each group, one user belongs to one group.
The user right shall not exceed the group right.
1.3 Camera Installation
Dome Installation
Step 1
If included please take the installation position map from the accessories bag,
and then paste it on the ceiling or the wall according to your monitoring area
requirements. Draw and then drill holes in the installation surface and then insert
expansion(anchor) bolts in the holes. Secure these bolts firmly.
Step 2
Turn counter clockwise to remove the decoration ring(plastic housing), turn the
pan base to the pedestal to loosen or secure firmly(metal housing) or Use the
inner hex wrench to remove the three enclosure fastening screws and then
remove the dome enclosure(glass enclousure). Adjust the pedestal position
according to the cable exit move(ceiling/side). Pull the cable through the cable
side exit at the installation surface and the pedestal.
(Please skip this step if you are mounting on a ceiling). Line up the screw holes
at the bottom of the pedestal to the expansion bolts in the installation surface.
Put three self-tapping screws to expansion bolts and then secure firmly. Now the
pedestal is on installation surface.
Plastic Housing
Ceiling or Wall
Expansion Bolt
Dome Camera Body
ST3 Self-tapping Screws
Decoration Ring
Metal Housing
Ceiling or Wall
Expansion Bolt
Pedistal 1
ST3 Self-tapping Screws
Glass Enclosure
Ceiling or Wall
Installation Position Map
Expansion Bolts
Enclosure fastening screw
Socket Screw
Inner Hex Wrench
Box Camera Lens Installation
Auto Aperture Lens
Please follow the steps listed below for auto aperture lens installation.

Remove the CCD protection cap of the device, and then line up the lens to
the proper installation position. Turn clockwise until the lens is fixed firmly.

Insert the lens cable socket to the auto lens connector in the side panel.

Adjust focus length.
Bullet Installation
Sun Shield Cover
Bracket
Before you install the bracket, please pull the cable through the cable exit of the bracket
chassis.
Important
The installation wall shall min sustain 3X weight of the bracket and camera.
Step 1
Paste the installation map on the surface of the wall or the ceiling.
Step 2
Dig the installation holes according to the installation map.
Step 3
Open the accessories bag and then take the expansion bolt out. Insert the expansion bolt into
the installation holes.
Step 4
Take the screws from the accessories bag and then use them to secure the device on the
installation surface of the wall or the ceiling. The sun shield of the device can move forward or
backward. Please secure the set screw of the sun shield after you fixed the device. Step 5
Connect the corresponding cables.
Step 6
Use the cross-head screwdriver to loosen the adjust screw.
Step 7
Turn the device in different directions to make it suitable for the monitor position.
Step 8
Use the cross-head screwdriver to fix the adjust screw firmly.
1.4 Variofocal lens
Each camera will be a
little different. Some
adjustable lens
cameras are adjusted
manually on the
camera.
VariFocal Camera
In other cameras the
adjustable lever can be
found in the inside of the
camera
Unscrew M2 5*5 Bolt from the
lower cover of the camera. Remove
the Cover and adjust the VariFocal
(zoom) to your preference.
Lens Focal Lens
Lower Cover
M2 5*5 Bolt
2.1 Multiple-function Combination Cable
You can refer to the following figure for multiple-function combination cable information. See Figure
2-1.
Figure 2-1
Please refer to the following sheet for detailed information.
Port Name
Function
Connection
Note
1.LAN
Network port
Ethernet
port
Connect to standard Ethernet cable.
2.DC12V
Power
port
/
Power input port. Input DC 12V.
input
3 Quick Configuration Tool
Please refer to the CD to find Configtools.exe
3.1 Overview
Quick configuration tool can search current IP address, modify IP address. At the same time, you can
use it to upgrade the device.
Please note the tool only applies to the IP addresses in the same segment.
3.2 Operation
Double click the “ConfigTools.exe”icon, you can see an interface is shown as in Figure 3-1.
In the device list interface, you can view device IP address, port number, subnet mask, default
gateway, MAC address and etc.
Figure 3-1
Select one IP address and then right click mouse, you can see an interface is shown as in Figure 3-2.
Note:
You can set the IP address, subnet mask and gateway for the IPC and PC. Please note IPC IP
address and PC IP address shall be in the same network segment if there is no router. IPC default IP
address is 192.168.1.108 or DHCP If there is a router, please set the corresponding gateway and subnet mask.
The factory default user name is admin and password is admin. For security reasons, please modify
your password after you first login.
For detailed WEB operation, please refer to the IPC Web Operation Manual in the resource CD.
Figure 3-2
Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure
3-3.
Figure 3-3
If you want to modify the device IP address without logging in the device web interface, you can go to
the configuration tool main interface to set.
In the configuration tool search interface (Figure 3-1), please select a device IP address and then
double click it to open the login interface. Or you can select an IP address and then click the Login
button to go to the login interface. See Figure 3-4.
In Figure 3-4, you can view device IP address, user name, password and port. Please modify the
corresponding information to login.
Please note the port information here shall be identical with the port value you set in TCP port in Web
Network interface. Otherwise, you can not login the device.
If you are use device background upgrade port 3800 to login, other setups are all invalid.
Figure 3-4
After you logged in, the configuration tool main interface is shown as below. See Figure 3-5.
Figure 3-5
For detailed information and operation instruction of the quick configuration tool, please refer
to the Quick Configuration Tool User’s Manual included in the resources CD.
4 Web Operation
This series IPC product support the Web access and management via PC.
Web includes several modules includes monitor channel preview, system configuration, alarm and etc.
4.1 Network Connection
Please follow the steps listed below for network connection.
z Make sure the IPC has connected to the network properly.
z Please set the IP address, subnet mask and gateway of the PC and the IPC respectively. IPC
default IP address is 192.168.1.108 or DHCP. Subnet mask is 255.255.255.0. Gateway is 192.168.1.1
z Use order ping ***.***.***.***(IP camera address) to check connection is OK or not.
4.2 Login and Logout
Open IE and input IP camera address in the address bar.
For example, if your camera IP is 192.168.1.108, then please input http:// 192.168.1.108 in IE address
bar.
Input your IP
address here
The login interface is shown as below.
Please input your user name and password.
Default factory name is admin and password is admin.
Note: For security reasons, please modify your password after you first login.
If it is your first time to login in, system pops up warning information to ask you whether install control
webrec.cab or not after you logged in for one minute. Please click OK button, system can
automatically install the control. When system is upgrading, it can overwrite the previous Web too.
If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable
the control download. Or you can lower the IE security level.
Please refer to the Web Operation Manual included in the resource CD for detailed operation
instruction.
5 FAQ
Bug
I can not boot up
the device or
operate properly.
Please click RESET button for at least five seconds to restore
factory default setup.
The water leakage
occurred.
The unauthorized front or rear cap remove many result in water
leakage.
The glass front cap has sustained heavy push or strike.
The waterproof plug of the rear cap becomes loosen.
IR video is poor.
Do not use the proper supplying power. The IR light can not turn on
completely.
The object is out of the IR distance range of current device.
IR-CUT does not turn to the night mode. The photosensitive chip of
the front-end can not sense the IR light.
I can not upgrade
the
device
via
network.
When network upgrade operation failed, you can use port 3800 to
continue upgrade.
I can not login the
client-end or the
WEB.
For Windows OS 98 or Windows ME user, if you can not install the
client-end or can not view after the installation. We recommend the
win2000sp4 OS or install the client-end of the low version.
The Active X control is blocked.
The display card version shall be dx8.1 or higher.
Network connection error occurred.
Invalid network setup.
Invalid user name or password.
I can not play the
download file.
There is no player.
There is no DX8.1 or higher.
For the MEDIA PLAYER, there shall be Div X503Bundle.exe plugin
if you play the .AVI file.
For Windows XP user, you need to install the plugin
DivX503Bundle.exe and ffdsho-2004 1012.exe.
To guarantee
setup update
After you modified the important setup, please reboot the device via
the software to make sure the setup has been updated to the
storage medium.
Power adapter
The power adapter included in the accessories bag can work
ranging from 0℃ to 40 ℃. The device may result in unstable power
supply when the temperature exceeds the working temperature.
Please replace an industry-level power adapter if you are using in
the harsh environments.
Appendix Toxic or Hazardous Materials or Elements
Component
Name
Toxic or Hazardous Materials or Elements
Pb
Hg
Cd
Cr VI
PBB
PBDE
Circuit Board
Component
○
○
○
○
○
○
Device
Construction
Material
○
○
○
○
○
○
Wire and Cable
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Packing
Components
Accessories
O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the
parts is below the relevant threshold of the SJ/T11363-2006 standard.
X: Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard. During the
environmental-friendly use period (EFUP) period, the toxic or hazardous substance or elements
contained in products will not leak or mutate so that the use of these (substances or elements) will not
result in any severe environmental pollution, any bodily injury or damage to any assets. The consumer
is not authorized to process such kind of substances or elements, please return to the corresponding
local authorities to process according to your local government statutes.
Note
z
This user’s manual is for reference only. Slight difference may be found in user interface.
z
All the designs and software here are subject to change without prior written notice.
z
If there is any uncertainty or controversy, please refer to the final explanation of us.
z
Please visit our website for more information.
Download PDF

advertising