Quickstart Guide
1
Charge
your Hub
2
Download
OpenSignals
3
Turn On
the Device
Make sure your hub has enough battery
Go to our website
to complete a task before using it; while charging
www.biosignalsplux.com/software
in order to turn on the hub;
a green light will turn on, which turns off
to download and install the software
a green light should start blinking.
automatically when the battery is fully charged.
for your operative system.
To fully charge your bioplux hub battery,
connect it to the charger provided with your kit
until the light turns off.
4
Configure
the Hub
5
To find and configure your new device
in OpenSignals, click the
The software will issue notifications
whenever new releases and improvements
are available.
button.
Press the center button once
%
&
#
'
$
(
On the biosignalsplux hub manual or data sheet
you will find detailed information about
the different states indicated by the light.
Connect
Sensors to Hub
Select and plug into
!
"
6
Start
Acquiring Data
To start a data visualization and recording session
one of the numbered analog inputs
in OpenSignals click the
button.
1-4 or 1-8 available on your hub.
Bluetooth settings depend on your OS.
Please refer to the device manual.
Some sensors require the use of a ground cable
to work properly; this cable can be connected
on the
socket.
After stopping your recording, data can be saved
through the
button; please refer to the
OpenSignals manual to learn about all its features.
Questions? Contact us at support@plux.info
©PLUX wireless biosignals 2017 | biosignalsplux Quick Start Guide 1.0.0 | 2017.05
Extend Your Kit
http://www.biosignalsplux.com/products/sensors
EMG
High performance bipolar sensor
with low noise characteristics for
seamless muscle data acquisition.
FSR
Thin film membrane force
sensor... perfect for
minimally intrusive setups.
BVP
Transmissive sensor with infrared
emitter and integral finger clip
for low noise and easy application.
RFID
The perfect accessory for synchronous
recording of biosignal data and
ID-mappable events.
EEG
ACC
Ideal for evoked potentials and
other localized EEG applications;
provides a single channel per sensor.
EDA
Triaxial accelerometer packed in
a miniaturized form factor
devised for non-intrusive sensing.
TMP
Discrete form factor, enables
sympathetic nervous system
monitoring at the hand or foot palms.
RIP
High resolution medical-grade
sensor, especially designed
for body temperature monitoring.
GON
Inductive sensor with adjustable
chest strap... high performance
even in dynamic settings.
Twin axis strain gage goniometer
with flexible connecting beam
for uncompromised range of motion
Load Cell
Precision sensor for handgrip,
traction, and other heavy
duty force sensing applications.
ECG
Single-lead local differential
bipolar sensor, designed for
improved user acceptability.
PZT
Affordable piezoelectric sensor with
adjustable chest strap... perfect for
basic sensing in low mobility settings.
VAG
This sensor is especially designed
for highh performance pelvic floor
EMG data acquisition.
Force Platform
Robust yet lightweight,
our force platform enables
uncompromised data acquisition.
Get Your Manuals
http://www.biosignalsplux.com/learn/documentation
All the latest documentation for our kits, components, sensors and software available at our website.
Questions? Contact us at support@plux.info
©PLUX wireless biosignals 2017 | biosignalsplux Quick Start Guide 1.0.0 | 2017.05
Specs & Maintenance
Electromagnetic emissions
See the table below for specific information regarding the bioPLUX electromagnetic emissions.
The bioPLUX is intended for use in the electromagnetic environment specified below.
The client and / or user of this device should ensure that it is used in such an environment.
Emissions test
Compliance
RF Emissions | CISPR 11
Group 1
RF Emissions | CISPR 11
Class B
Harmonic Emissions | IEC 61000-3-2
A
Voltage fluctuations / Flicker Emission IEC 1000-3-3
Conforms
Electromagnetic Environment - Guidance
This device must emit electromagnetic energy in order to perform its function.
Electronic equipment near it, may be affected.
This device is suitable for use in all establishments, including domestic and
those directly connected to low-voltage energy public network supply which
supplies buildings used for domestic purposes.
Table 1: Electromagnetic Emissions
This device is suitable for use in all establishments, including domestic and those directly connected to low-voltage energy public network supply which supplies buildings
used for domestic purposes.
Technical specifications
bioPLUX device
Analog Ports: 8 generic inputs
Auxiliary Ports: 1 digital I/O + 1 ground
Resolution: up to 16-bit (per channel)
Sampling Rate: up to 1000Hz (per channel)
Communication: Bluetooth Class II
Range: up to ~10m (extendable)
Internal Memory: (optional extra)
Battery Life: ~10h streaming
Size: 85x54x10mm
Weight: 46gr
Hub specifications
Charger | FW7600/09 charger with universal battery
Input 100 to 240 V~, 50 to 60 Hz, 0.5A
Output 5V, 1.2A
Medical grade charger safety approvals and certifications: UL60601-1, CUL TO 22.2 no. 601.1-M90, INNOVA BAUART to
EN60601-1, CE CLASS II, PSE to J60601-1, CB REPORT TO IEC 60601-1:2005 (3rd edition), AS/NZ to 60601-1, C-TICK to
EN55011, CCC
CE marked: tested to comply with EN61000-3-2, EN61000-3-3, EN60601-1-2 2001, INCLUDING EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11. Complies to section 301 of energy
independence and security act.
Conforms with
Maintenance recommendations
Cleaning
The bioPLUX equipment and sensors should be visually checked before each use to ensure that no mechanical damage has occurred.
• The bioPLUX equipment and sensors (including the cables) should be cleaned with a slightly damp cloth or suitable absorbent paper,
ensuring that no liquid enters the equipment or sensors. Do not use detergent or any type of cleaning liquid.
• Clean the bioPLUX equipment separately from the sensors
• Do not clean or re-use detection surfaces. They are only suitable for single use, and should be disposed of after usage.
•
Transport and storage
• When the equipment and accessories are not being used, they should be stored in the original box in a dry place:
– Relative humidity: up to 95% with no condensation
– Ambient temperature: 10ºC to 30ºC
– Atmospheric pressure between 500 hPa and 1060hPa
• Whenever the equipment needs to be transported, it should be placed in the original box, since this was designed and tested to ensure the equipment
and accessories are securely stored;
• Take care while handling the bag and avoid dropping it, since the device is not shock-proof and should not be placed under stress or sudden acceleration.
PLUX can not be held responsible if the system is transported outside it’s original box or in any other type of unsuitable packaging, which may invalidate the guarantee.
Questions? Contact us at support@plux.info
©PLUX wireless biosignals 2017 | biosignalsplux Quick Start Guide 1.0.0 | 2017.05
Indications & Warnings
User Manual and Software
To download the software and latest user manual go to:
http://www.biosignalsplux.com/learn/documentation
Do not open the bioPLUX or its accessories. The repair of the same should
be only done by properly authorized PLUX personnel.
Intended Use
By connecting the bioPLUX to the transformer for batteries recharge,
place the device so that the cable is free, away from places where it
can be walked on or damaged. Make sure the cable does not obstruct
the passage of people.
Research Use Only, not for Use in Diagnostic Procedures. biosignalsplux
products are intended for use in life science education and research ap
plications; they are not medical devices nor are they intended for medical
diagnosis, cure, mitigation, treatment or prevention of disease.
Contraindications
Do not use this device in patients with implanted electronic devices of
any kind, including pace-makers, electronic infusion pumps, stimulators,
defibrillators or similar
Do not apply electrodes over damaged skin.
Do not use the system in patients with allergies to silver.
Warnings and Precautions
See all the documentation that came with the system for instructions on
safety and precaution.
See the User’s Guide for detailed instructions about bioPLUX and sensors.
Always keep the device and its accessories dry. The presence of liquid
contact can compromise the safety operating characteristics of the sys
tem. Do not immerse the sensors or the bioPLUX, nor clean with liquid
or with abrasives. Read the manual to learn how to clean up the bioPLUX
and sensors.
Fragile. Handle with caution. Do not expose the device or accessories to
high accelerations and vibrations.
Do not use this equipment in an environment with operating magnetic
resonance imaging devices (MRI).
Do not use the device near the fire or in potentially explosive atmospheres,
such as atmospheres with flammable gas.
The use of damaged accessories or not recommended by PLUX may result
in changes to the technical characteristics and features of your bioPLUX.
Use only approved accessories purchased from PLUX or an PLUX agent.
Use only the detection surfaces provided on the packaging of the system
or acquired from PLUX or an PLUX agent.
The detection surfaces provided are single-user and disposable.
Use only the transformer supplied with the package of the system or
purchased from PLUX or an PLUX agent.
Inspect the sensors on a regular basis to ensure that they remain in good
working order.
If you experience any kind of discomfort or skin irritation when using the
clinical bioPLUX, discontinue using it immediately.
Use the sensor cables with extreme caution to avoid risk of strangulation.
The bioPLUX may suffer or cause interference to other equipment with
radio receiver / transmitters, even those that comply with international
standards. Keep a safe distance between the bioPLUX and other devices
to ensure their proper functioning. The bioPLUX should not be used in
noisy environments in relation to RF radiation wich can cause communi cation failures with the computer.
If your bioPLUX stops working properly, do not use it until you send it
for repair by qualified PLUX personnel.
Complies with Requirements put forth by the Medical Device Directive
93/42/EEC. Class I device, Annex VII.
Type BF Device (IEC 60601-1)
Isolated device. (Class II, EEC 60601-1)
In compliance with the European Directive on Waste of Electrical and
Electronic Equipment (WEEE) 2002/96/EC, do not deposit the bioPLUX
in the trash. Instead, contact your Reseller or PLUX for properly recycle
your bioPLUX. You can get information about the contact nearest to you
in http://www.plux.info.
Date of Manufacturing (appears on product packaging).
Serial Number (appears on product packaging and bioPLUX).
The bioPLUX device should be used at temperatures between 10º and
40ºC and stored at temperatures between 10º and 30ºC because it has
rechargeable Li-Ion batteries and detection surfaces with limitations
on operating temperatures. Operating or storing the device outside this
range may compromise the integrity and security of it.
This equipment complies with International Standard EN 60601-1-2:2001
for electromagnetic compatibility for medical equipment and systems.
This pattern is used to provide reasonable protection against harmful
interference in a typical medical environment. However, the proliferation
of devices using radio frequencies can cause interference that can reach
the limit to prevent the proper functioning of your bioPLUX. Keep your
equipment installed in accordance with their instructions.
Use bioPLUX within the limits of communication with the receiving
equipment of the wireless signal: in a radius of approximately 10 meters
for the Bluetooth connection. Working with the device outside of this
range of communication can lead to data loss and faulty communica tions. See user manual for more details.
Do not place the device in the microwave.
If the bioPLUX system or accessories reach uncomfortable temperatures,
turn off the bioPLUX immediately and contact Technical Support.
Do not insert objects into the holes of the device, it may affect the operating characteristics, and safety.
Zona Industrial das Corredouras - Lote 14, 1º
2630-369 Arruda dos Vinhos | PORTUGAL
Questions? Contact us at support@plux.info
©PLUX wireless biosignals 2017 | biosignalsplux Quick Start Guide 1.0.0 | 2017.05