Hand Dryers
CYCA18F
Automatic operation
1
Hand Dryer
Operating Instructions and Parts Manual (Automatic)
CYCA18F
Description: CYCA18F
Automatic operation hand dryer.
Casing: Made of high grade fire retardant ABS, 3.0 mm thick.
Brush motor : 80W, 2850 R.P.M. (50Hz)
Designed with 105 C (221 F) thermostat.
Heater assembly : Designed with 87 C (200 F) thermostat.
Designed with 141 C (323 F) thermal cut-off.
3
Dryer shall deliver 255 m/h (150 CFM).--50Hz.
Air speed : 14.5 m/s.--50Hz
Sound level : 55+3 db.
Approximately 30-35 seconds drying time.
Adjustable sensitive distance of sensor from 10 to 30 cm.
Power cut off automatically in case of irregular use over 120 seconds.
Drip proof : IPX1
Weight: 3.8kgs (8.4 lbs) unpacked ; 4.5kgs (9.9 lbs) packed.
Specifications and Dimensions
Model
CYCA18F
Volts
230-240Vac
Watts
1653-1800W
Housing Dimensions: mm (in)
L
W
H
Amps
7.2-7.5A
268(10 1/2)
L
W
H
2
220(8 3/4)
170(6 3/4)
Hand Dryers
Operating Instructions and Parts Manual
General safety information
CYCA18F
WARNING Disconnect power before
installation or servicing.
WARNING This product intended for
installation by a qualified service person.
Use AWG NO. 14 solid conductor for wiring.
WARNING All units must be supplied with
a 3-wire service. The ground wire must be
connected to the dryer's backplate.
DANGER Failure to properly ground unit
could result in severe electrical shock and/or death.
NOTE: Do not install dryer over washbasin.
Wiring Diagrams
Thermal
Cut-off
Heater
G
Sensor
Motor
C
Capacitor
Relay Contact
Timer
Installation
1. Fix the position card on the wall.
Suitable height for hole "D" is 130 cm (50") from ground.
2. Drill 4 holes
(A. B. C. D. 8 mm (5/16") diameter:35 mm (3/8") depth.)
3. Take off the mounting instruction sheet.
Hammer dowels into 4 holes.
4. Remove the housing from the base plate; fix the base
plate firmly on to the wall.
5. Connections:
A. Connect the live wire (colored red or brown) to
the terminal block marked "L".
B. Connect the neutral wire (colored black or blue)
to the terminal block marked "N".
C. Connect the ground wire (colored green and
yellow) to the green screw marked " ".
6. Attach housing back to base plate.
3
N
L
Thermostat
Hand Dryers
Operating Instructions and Parts Manual
Operation
CYCA18F
Shake excess water from hands.
Place hands under the outlet to start operation.
Rub hands lightly and rapidly.
Stops automatically when hands are removed.
Maintenance
Easy to maintain. If the surface is dirty or dusty
just wipe to clean.
Troubleshooting Chart
Symptom
Corrective Action
Blower motor stops running
Turn off power to the dryer at electrical panel.
Remove cover.
Check all wiring connections from terminal board to the
motor.
Check blower wheel and spin to make sure it rotates freely:
Look for objects blocking the free movement.
Replace cover and turn on power to the hand dryer.
If motor fails to start, have a qualified electrician check the
Push-On-Switch, thermostat, motor and capacitor for proper
operation. Replace if necessary.
Dryer blows cold air
Turn off power to the dryer at the electrical panel.
Remove cover.
Check all wiring connections to make sure all terminals are
firmly mounted in place and the wire insulation is in
good condition.
Have a qualified electrician check the thermal cut off and
heating element.
Replace cover, turn on power to the hand dryer. If dryer
continues to blow cold air, replace defective thermal cut
off and/or heating element.
Dryer does not respond
to hand movement
Make sure power is on and available to the unit. Place
hands under sensor.
A clicking sound indicates sensor is functioning properly.
No clicking sound would indicate a bad sensor and/or
contactor.
Replace if necessary.
Dryer will not shut off or will
not run for a complete cycle
Replace timer assembly
4
Hand Dryers
Operating Instructions and Parts Manual
CYCA18F
5
Operating Instructions and Parts Manual
Hand Dryers
Repair parts list
Part number for
CYCA18F
Reference
Number
Description
CYCA18F
Qty.
1
2
3
4
5
Enclosure
Name plate
Plate
Grounding screw
Power terminal block
A13-0001
K13-0001
K13-0002
D01-002
F01-005
1
1
1
1
1
6
7
8
9
10
Insulating barrier
Power cord
Bushing
Motor
Sensor
A01-001-1
------A01-002
E01-002-02(230Vac)
11
12
13
14
15
Timer assembly
Base plate
Fix screw
Thermostat
Heater assembly
F02-003
TIA02-2(230Vac)
C04-003
D13-0001
F01-004
HE09(230Vac)
1
1
1
1
16
17
18
19
Fan enclosure
Air outlet guard
Fan blower
Motor capacitor
C11-0001
C01-013
C01-001-1
F01-001-1
1
1
2
1
1
1
1
1
1
Hyco Manufacturing Ltd
Normandy Court
Express Way
Castleford
West Yorkshire
WF10 5NR
United Kingdom
6
Tel:01924 225 200 Fax:01924 225 210
Web:www.hyco.co.uk Email:sales@hyco.co.uk