First Co. Certificate of Product Ratings

First Co. Certificate of Product Ratings
FC-1/OHP-9
First Co. Certificate of Product Ratings
First Co. Certified Reference Number: F106882
Outdoor Unit Manufacturer:
CARRIER
Outdoor Unit Model Number:
25HCE436C*030*
Print Date: 8/7/2017
First Co. Indoor Model Number: 37HXX
Cooling Capacity (MBTUH):
34.0
EER (Cooling)
12.00
SEER (Cooling):
14.00
Heating Capacity (MBTUH):
HSPF (Heating):
34.8
8.2
First Co. certifies that the capacity and SEER values shown are calculated using the methodology in
Section 430.23(M) of 10CFR Part 430. The calculation procedure utilizes test data collected in accordance
with ANSI/AHRI 210/240-2008.
DOE Requirement
Effective July 5, 2011, the U.S. Department of Energy (DOE) issued a Final Rule (10 CFR Parts 429-431) that
expands the existing certification, compliance, and enforcement requirements for all covered products, including
Residential and Commercial HVAC products. As part of the Final Rule, all efficiency information for covered products must be on file with DOE. All First Co. ratings have been submitted to DOE.
Certification Vertification
The above rating information can be verified on either of the following web sites:
First Co.: ratings.firstco.com
DOE: www.regulations.doe.gov/certification-data
Void Date: 07/01/2018
FC-2/OHP-10
First Co. Certificate of Product Ratings
First Co. Certified Reference Number: F106728
Outdoor Unit Manufacturer:
CARRIER
Outdoor Unit Model Number:
25HBC524A*030*
Print Date: 8/7/2017
First Co. Indoor Model Number: 25HXX
Cooling Capacity (MBTUH):
23.4
EER (Cooling)
11.20
SEER (Cooling):
14.00
Heating Capacity (MBTUH):
HSPF (Heating):
24.0
8.2
First Co. certifies that the capacity and SEER values shown are calculated using the methodology in
Section 430.23(M) of 10CFR Part 430. The calculation procedure utilizes test data collected in accordance
with ANSI/AHRI 210/240-2008.
DOE Requirement
Effective July 5, 2011, the U.S. Department of Energy (DOE) issued a Final Rule (10 CFR Parts 429-431) that
expands the existing certification, compliance, and enforcement requirements for all covered products, including
Residential and Commercial HVAC products. As part of the Final Rule, all efficiency information for covered products must be on file with DOE. All First Co. ratings have been submitted to DOE.
Certification Vertification
The above rating information can be verified on either of the following web sites:
First Co.: ratings.firstco.com
DOE: www.regulations.doe.gov/certification-data
Void Date: 07/01/2018
EL
FC-1 AND 2
X)
D
O HX
M 28
(
EW ED
N D
D
A
HXX(-C) Series
Horizontal Recessed
Ceiling Fan Coil
1.5 - 3.0 Tons Cooling or Heat Pump
0 - 10 kW Electric Heat
These recessed ceiling fan coils are designed for use with today's
higher efficiency split-system condensing units and heat pumps.
High efficiency ECM type motors are standard in all HXX series
fan coils.
HXX Fan Coil
Optional Access Panel
(non-louvered shown)
(see P. 3 for information)
Optional Insulated Enclosure
(see P. 3 for information)
Matching Access Panel for Enclosure
(non-louvered shown)
(see P. 3 for information)
The base HXX fan coil is an open blower type (non-enclosed)
fan coil. It is also available with either a field or factory installed
enclosure, with both options including your choice of either a
louvered or solid ceiling panel. For HXX fan coils factory installed
within an enclosure, add "-C" after the kW in the model number.
For instance, ordering model 19HXX5-C R410 TXV, will include an
19HXX5 R410 TXV fan coil factory installed in a number 9EHX01
enclosure and your choice of either a solid or louvered panel
(see "Enclosures with Ceiling Panels" on P. 3). A "cap kit" is also
available when the HXX is installed above a ceiling, rather than
recessed (see P. 4).
Compatible outdoor units: First Co's customer is ultimately
responsible for confirming which fan coil models are compatible with selected outdoor units. To determine certified
indoor/outdoor matches, go to www.firstco.com or contact
the factory.
Standard Features:
•
•
•
•
•
•
•
High efficiency ECM motor
Drain pan has 3/4" NPT primary and secondary (overflow) fittings
240V motor, 24V control
Factory installed electric heat (up to 10 kW) (except 0 kW models)
Highly efficient copper tube/aluminum fin cooling coil with factory installed R-410A TXV (non-bleed type)
Insulated and coated galvanized steel drain pan, sloped for positive drainage
Effective January 2016, Cabinet air leakage is no more than 2% when tested in accordance with ASHRAE 193. Optional Features:
•
•
•
•
•
•
Attractive off-white return air / access panel with captive screws. They can be used with either the non-
enclosed HXX or the HXX with a field or factory installed
enclosure.
IAQ filter panels (see P. 3)
Field installed enclosure. All enclosures are fully
insulated and include cutouts for optional ducted return air. Ducted return air option requires remote filter-grille.
Heat pump kit - required for all HXX models having electric heat (#942-1). (P. 2)
Condensate overflow switch (# SS3) (field installed)
Enclosure "Cap Kit" - for above the ceiling installation (P. 4)
FIRST CO. - P.O. Box 270969 - Dallas, Texas 75227 - Ph. (214) 388-5751 - Fax (214) 388-2255 - www.firstco.com
HXX(-C) Series
1.5 through 3.0 tons
Approved for installation with
0" clearance to combustible
materials
SUCTION LINE
5/8 SWEAT: 19HXX
7/8 SWEAT: 25-37HXX
LIQUID LINE - 3/8 SWEAT
(See P. 4 for Model Numbers)
PERFORMANCE DATA
NOM.
CFM
UNIT MODEL
FC-2
FC-1
19HXX
20HXX
-0
-3
-5
-6
-8
-10
25HXX
26HXX
28HXX
-0
-3
-5
-6
-8
-10
31HXX
32HXX
-0
-3
-5
-6
-8
-10
37HXX
-0
-3
-5
-6
-8
-10
PHYSICAL DIMENSIONS
600
800
1000
1200
NOM.
COOL
BTUH
HEAT (1)
TOTAL AMPS
MIN. CIR.
AMPACITY
MAX FUSE
kW
BTUH
208V
240V
208V
240V
208V
240V
18,000
--3
5
6
8
10
--10,200
17,000
20,500
27,300
34,100
4.3
15.2
22.4
26.0
33.2
40.4
4.3
16.8
25.2
29.3
37.7
46.0
--19
28
33
42
51
--21
32
37
47
58
--20
30
35
50
60
--25
35
40
50
60
24,000
--3
5
6
8
10
--10,200
17,000
20,500
27,300
34,100
4.3
15.2
22.4
26.0
38.2
40.4
4.3
16.8
25.2
29.3
37.7
46.0
--19
28
33
42
51
--21
32
37
47
58
--20
30
35
50
60
--25
35
40
50
60
30,000
--3
5
6
8
10
--10,200
17,000
20,500
27,300
34,100
4.3
15.2
22.4
26.0
33.2
40.4
4.3
16.8
25.2
29.3
37.7
46.0
--19
28
33
42
51
--21
32
37
47
58
--20
30
35
50
60
--25
35
40
50
60
36,000
--3
5
6
8
10
--10,200
17,000
20,500
27,300
34,100
4.3
15.2
22.4
26.0
33.2
40.4
4.3
16.8
25.2
29.3
37.7
46.0
--19
28
33
42
51
--21
32
37
47
58
--20
30
35
50
60
--25
35
40
50
60
MODEL
A
B
C
D
19HXX
37-1/4
34-11/16
30
6-1/2
20,25HXX
43-1/4
40-11/16
36
6-1/2
26,31HXX
49-1/4
46-11/16
42
6-1/2
28,32,37HXX
56-1/4
53-11/16
49
6-1/2
HEAT PUMP KIT (FIELD INSTALLED)
PART NO.
DESCRIPTION
942-1
KIT FOR HXX MODELS WITH ELECTRIC HEAT
Note: Heat pump kit must be field installed for all HXX models
with electric heat. 0 kW models do not require kit. Contact the
factory for compatibility match with condensing unit.
(1) All BTUH heating ratings at 240V - derate heating capacities
by 25% for 208V
(2) Maximum fuse or HACR-type circuit breaker.
BLOWER DATA
MOTOR
HP
(240V)
SPEED
TAP
MOTOR
BHP
NOM.
AMPS
0.00
0.05
0.10
0.15
0.20
0.25
0.30
0.35
0.40
19HXX
1/2
OPTIONAL HIGH
STD. HIGH
STD. LOW
.16
.10
.08
1.2
.08
.07
800
660
590
765
630
555
730
600
520
695
575
495
660
550
470
620
525
445
580
500
420
535
-----
490
-----
20HXX
1/2
OPTIONAL HIGH
STD. HIGH
STD. LOW
.16
.10
.08
1.2
0.8
0.7
800
650
590
765
625
560
730
600
530
695
575
505
660
550
480
620
525
455
580
500
430
535
-----
490
-----
25HXX
28HXX
1/2
OPTIONAL HIGH
STD. HIGH
STD. LOW
.30
.20
.16
2.1
1.5
1.0
970
810
720
950
790
690
930
770
660
910
745
645
890
720
630
870
705
615
850
690
600
825
-----
800
-----
26HXX
1/2
OPTIONAL HIGH
STD. HIGH
STD. LOW
.30
.20
.16
2.1
1.5
1.0
1010
840
750
980
810
715
950
780
680
925
760
655
900
740
630
880
720
615
860
700
600
840
-----
820
-----
31HXX
1/2
OPTIONAL HIGH
STD. HIGH
STD. LOW
.43
.32
.24
3.3
2.2
1.5
1230
1060
920
1195
1015
885
1160
970
850
1140
945
810
1120
920
770
1090
875
735
1060
830
700
995
-----
930
-----
32HXX
1/2
OPTIONAL HIGH
STD. HIGH
STD. LOW
.43
.32
.24
3.3
2.2
1.5
1280
1090
950
1245
1050
920
1210
1010
890
1180
985
855
1150
960
820
1115
930
790
1080
900
760
1025
-----
970
-----
37HXX
1/2
OPTIONAL HIGH
STD. HIGH
STD. LOW
.51
.43
.32
4.0
3.3
2.2
1430
1260
1110
1400
1225
1080
1370
1190
1050
1355
1160
1025
1320
1130
1000
1295
1115
970
1270
1100
940
1220
-----
1170
-----
UNIT
MODEL
CFM vs. EXTERNAL STATIC PRESSURE
(1) Add .05 static when enclosure is used.
-2-
In keeping with its policy of
continuous progress and product
improvement, First Co. reserves
the right to make changes without
notice. Maintenance for all First
Co. products is available under
"Product Maintenance" at
www.firstco.com.
Ceiling Access Panels - (For HXX's installed without enclosure)
CEILING ACCESS PANELS
FOR MODEL
19HXX
20, 25HXX
26, 31HXX
28, 32, 37HXX
PANEL
NO.
(STD.)
PANEL
NO.
(IAQ)
CEILING
PANEL
OPENING
DESCRIPTION
PANEL FRAME
DIMS.
(OUTSIDE)
965
965-M8
LOUVERED
24-1/2
40
27-1/2
43
965-1
NA
NON-LOUVERED
24-1/2
40
27-1/2
43
966
966-M8
LOUVERED
24-1/2
46
27-1/2
49
966-1
NA
NON-LOUVERED
24-1/2
46
27-1/2
49
967
967-M8
LOUVERED
24-1/2
52-1/2
27-1/2
55-1/2
967-1
NA
NON-LOUVERED
24-1/2
52-1/2
27-1/2
55-1/2
967-6
967-6-M8
LOUVERED
24-1/2
60
27-1/2
63
967-7
NA
NON-LOUVERED
24-1/2
60
27-1/2
63
STANDARD PANELS
# 965-1, 966-1,
967-1, 967-7
IAQ PANELS
# 965-M8 (accepts 1-20x30x1 filter)
# 966-M8, 967-M8 (accepts 2-20x20x1 filter)
# 967-6-M8 (accepts 2-20x25x1 filter)
(GlasFloss ® Industries Series
HV filter or equivalent is recommended)
# 965, 966, 967, 967-6
(Louvers may differ from picture)
Louvered panels accept 20x20x1" filter
(field supplied)
Enclosures with Ceiling Panels
(Enclosures and panels are standard with ALL "-C" models or
can be ordered separately for "HXX" models)
CEILING PANEL / ENCLOSURE INFORMATION
FOR MODEL
19HXX
20, 25HXX
26, 31HXX
28, 32, 37HXX
ENCLOSURE
DIMENSIONS
ENCLOSURE
NO.
9EHX01
9EHX02
H
W
D
11
39-3/4
23-7/8
11
9EHX03
11
9EHX04
11
45-3/4
51-3/4
58-3/4
23-7/8
23-7/8
23-7/8
PANEL
NO.
(STD.)
PANEL
NO.
(IAQ)
DESCRIPTION
(2)
CEILING PANEL
OPENING
PANEL FRAME
DIMS (OUTSIDE)
W
L
W
L
965
965-M8
LOUVERED
24-1/2
40
27-1/2
43
965-1
NA
NON-LOUVERED
24-1/2
40
27-1/2
43
966
966-M8
LOUVERED
24-1/2
46
27-1/2
49
966-1
NA
NON-LOUVERED
24-1/2
46
27-1/2
49
967
967-M8
LOUVERED
24-1/2
52-1/2
27-1/2
55-1/2
967-1
NA
NON-LOUVERED
24-1/2
52-1/2
27-1/2
55-1/2
967-6
967-6-M8
LOUVERED
24-1/2
60
27-1/2
63
967-7
NA
NON-LOUVERED
24-1/2
60
27-1/2
63
(See Panel Pictures Above)
NOTES:
(1) Louvered is the "default" style and automatically shipped unless non-louvered is specified on order.
6-7/8
FRONT VIEW (SUPPLY)
END VIEW
REAR VIEW (RETURN)
11
2-13/16 4-1/2
2
23-7/8
2-1/2
"B"
7
5-7/8
"C"
"A"
KNOCKOUT FOR
DUCTED RETURN
(Requires remote filter
grille - field supplied)
(Ducted return requires
non-louvered panel)
ENCLOSURE DIMENSIONS
FOR MODEL
ENCLOSURE
NO.
A
B
C
19HXX
9EHX01
39-3/4
30-5/8
28
20, 25HXX
9EHX02
45-3/4
36-5/8
34
26, 31HXX
9EHX03
51-3/4
42-5/8
40
28, 32, 37HXX
9EHX04
58-3/4
50
46-3/4
Picture shown is enclosure with installed HXX
(Available from the factory as a complete unit)
-3-
HXX(-C) Series
1.5 through 3.0 tons
MODEL NUMBERS:
UNCASED (NO ENCLOSURE)
FACTORY INSTALLED ENCLOSURE
(ALL WITH FACTORY
INSTALLED R410A TXV)
(ALL WITH FACTORY
INSTALLED R410A TXV)
MODEL SIZE (BTU)
MODEL
MODEL
18,000
19HXX(*) R410 TXV
19HXX(*)-C R410 TXV
18,000
20HXX(*) R410 TXV
20HXX(*)-C R410 TXV
24,000
25HXX(*) R410 TXV
25HXX(*)-C R410 TXV
24,000
26HXX(*) R410 TXV
26HXX(*)-C R410 TXV
24,000
28HXX(*) R410 TXV
28HXX(*)-C R410 TXV
30,000
31HXX(*) R410 TXV
31HXX(*)-C R410 TXV
30,000
32HXX(*) R410 TXV
32HXX(*)-C R410 TXV
36,000
37HXX(*) R410 TXV
37HXX(*)-C R410 TXV
All TXVs are approved for cooling only or heat pump operation (non-bleed type).
(*) = kW HEAT
ENCLOSURE INSTALLATION SUPPORT FRAMING
Ceiling
Wood or Metal
Frame All Sides
Louvered Ceiling Panel
Sheet Rock
ENCLOSURE CONNECTION LOCATIONS
CAP KIT - FOR INSTALLATION ABOVE A SUSPENDED CEILING
Optional Return
Air Cutout
Refrigerant Line
Connections
Drain
Connections
Catalog No. HXX517 (replaces hxx816)
PART NO.
FITS ENCLOSURE NO.
9PHX01
9EHX01
19HXX-C
9PHX02
9EHX02
20, 25HXX-C
9PHX03
9EHX03
26, 31HXX-C
9PHX04
9EHX04
28, 32, 37HXX-C
FOR UNIT MODEL
NOTES:
1. Cap kit is an insulated panel that covers the entire bottom opening of the enclosure (requires ducted return)
2. Cap kit would be used in lieu of the ceiling panel
Electrical
Connections
-4-
25HCE4
Comfort™ 14 Heat Pump
with Puronr Refrigerant
1---1/2 to 5 Nominal Tons
Product Data
OHP-1
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 14 SEER / 11.0 -- 11.7 EER / 8.2 HSPF
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 69 dBA
S Sound levels as low as 68 dBA with accessory sound blanket
Comfort
S System supports CôRt, Edger or standard thermostat controls
Reliability
S
S
S
S
S
S
S
S
Non--ozone depleting Puronr refrigerant
Scroll compressor
Internal pressure relief valve
Internal thermal overload
High pressure switch
Loss of charge switch
Filter drier
Balanced refrigeration system for maximum reliability
Durability
Carrier heat pumps with Puronr refrigerant provide a collection of
features unmatched by any other family of equipment. The
25HCE4 has been designed utilizing Carrier’s non--ozone
depleting Puronr refrigerant.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.
WeatherArmort protection package:
S Solid, durable sheet metal construction
S Dense wire coil guard
S Baked--on powder paint
Applications
S Long--line -- up to 250 feet (76.20 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)
S Low ambient (down to --20_F/--28.9_C) with accessory kit
MODEL NUMBER NOMENCLATURE
1
N
2
N
3
A
4
A
5
A/N
6
N
7
N
8
N
9
A/N
10
A/N
11
A/N
12
N
13
N
2
5
H
C
E
4
3
6
A
0
0
3
0
Open
Open
Voltage
0=Not
Defined
0=Not
Defined
3=208/230/1
5=208/230/3
6=460/3
Product
Series
25 = HP
Product
Major
Tier
Family
Series
H = RES HP C=Comfort E = Puron
Cooling
Capacity
SEER
4=14 SEER
Grille
Variations
A=Dense Grille
Minor
Series
0, 1, 2...
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
STANDARD FEATURES
Feature
18
24
30
36
42
48
60
Puron Refrigerant
X
X
X
X
X
X
X
Scroll Compressor
X
X
X
X
X
X
X
Field Installed Filter Drier
X
X
X
X
X
X
X
Front Seating Service Valves
X
X
X
X
X
X
X
Internal Pressure Relief Valve
X
X
X
X
X
X
X
Internal Thermal Overload
X
X
X
X
X
X
X
Long Line capability
X
X
X
X
X
X
X
Low Ambient capability with Kit
X
X
X
X
X
X
X
Suction Line Accumulator
X
X
X
X
X
X
X
High Pressure Switch
X
X
X
X
X
X
X
Loss of Charge Switch
X
X
X
X
X
X
X
X = Standard
2
PHYSICAL DATA
OHP-9
UNIT SIZE SERIES
18--- 30
24--- 30
30--- 30
36--- 31, 51, 61
42--- 30
48--- 30, 50, 60
60--- 30
60--- 50, 60
Compressor Type
Scroll
REFRIGERANT
Puron (R---410A)
Control
TXV (Puron Hard Shutoff)
Outdoor Heating Piston #
42
46
49
57
61
65
73
78
Charge lb (kg)
5.30 (2.4)
5.60 (2.5)
6.40 (2.9)
7.67 (3.48)
8.25 (3.74)
8.68 (3.94)
10.60 (4.81)
10.60 (4.81)
COND FAN
Forwrard Swept or Propeller Type, Direct Drive
Air Discharge
Vertical
Motor HP
1/12
1/10
1/4
1/5
1/4
1/4
1/4
1/4
Motor RPM
1100
1100
1100
1100
1100
1100
800
800
CFM
1700
2195
3365
3165
3800
3365
4470
4470
VALVE CONNECT. (In. ID)
Vapor
5/8
5/8
3/4
3/4
7/8
7/8
7/8
7/8
Liquid
3/8
REFRIGERANT TUBES* (In. OD)
Rated Vapor
5/8
5/8
3/4
3/4
7/8
7/8
1 ---1/8
1 ---1/8
Max Liquid Line
3/8
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for HP systems with Puron refrigerant:
Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications
Unit Nominal Size
(Btuh)
Acceptable
Vapor Line
Diameters
(In. OD)
Cooling Capacity Loss (%)
Total Equivalent Line Length (ft)
Standard Application
Long Line Application Requries Accessories
25
(7.62)
50
(15.2)
80
(24.4)
80+
(24.4+)
100
(30.48)
125
(38.10)
150
(45.72)
175
(53.34)
200
(60.96)
225
(68.58)
250
(76.20)
18000
1--- Stage HP
1/2
1
2
3
3
4
6
7
8
9
10
12
5/8
0
0
1
1
1
1
2
2
3
3
3
24000
1--- Stage HP
5/8
0
1
1
1
2
3
3
4
4
5
6
3/4
0
0
0
0
0
1
1
1
1
1
2
5/8
1
2
3
3
3
4
5
6
7
8
9
3/4
0
0
1
1
1
1
2
2
2
3
3
7/8
0
0
0
0
0
1
1
1
1
1
1
5/8
1
2
4
4
5
6
7
9
10
11
13
3/4
0
0
1
1
1
2
2
3
3
4
4
7/8
0
0
0
0
0
1
1
1
1
2
2
42000
1--- Stage HP
3/4
0
1
2
2
2
3
4
4
5
6
6
7/8
0
0
1
1
1
1
2
2
2
3
3
48000
1--- Stage HP
3/4
0
1
2
2
3
4
5
5
6
7
8
7/8
0
0
1
1
1
2
2
2
3
3
4
3/4
1
2
4
4
5
6
7
9
10
11
12
7/8
0
1
2
2
2
3
4
4
5
5
6
1 1/8
0
0
0
0
1
1
1
1
1
1
2
30000
1--- Stage HP
36000
1--- Stage HP
60000
1--- Stage Puron HP
Standard Length = 80 ft. (24.4 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
3
ELECTRICAL DATA
UNIT SIZE
V/PH
OPER VOLTS*
MAX
COMPR
MIN
FAN
LRA
RLA
MAX
FUSE** or
CKT BRK
AMPS
20
25
30
30
40
40
50
20
25
30
15
15
15
MCA
FLA
18 --- 30
48.0
9.00
0.50
11.8
24 --- 30
62.9
10.90
0.60
14.2
30 --- 30
72.5
13.50
1.40
18.3
36 --- 31
208/230/1
253
197
75.0
15.10
1.10
20.0
42 --- 30
105.5
18.10
1.40
24.0
48 --- 30
108.0
19.00
1.40
25.2
60 --- 30
144.2
24.40
1.52
32.0
36 --- 51
70.0
8.46
1.10
11.7
48 --- 50
208/230/3
253
187
123.0
10.44
1.40
14.5
60 --- 50
110.0
15.96
1.52
21.5
36 --- 61
31.0
3.85
0.60
5.4
48 --- 60
460 ---3
506
414
60.0
6.00
0.77
8.3
60 --- 60
52.0
7.75
0.77
10.5
* Permissible limits of the voltage range at which the unit will operate satisfactorily
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1
A--WEIGHTED SOUND POWER
UNIT SIZE
18--- 30
24--- 30
30--- 30
36--- 31, 51, 61
42--- 30
48--- 30, 50, 60
60--- 30
60--- 50, 60
STANDARD
RATING
(dBA)
69
76
77
77
76
79
73
76
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125
250
500
1000
2000
4000
8000
45
46
52
51
49
53
50
52
48
56
62
62
61
66
63
62
56
59
67
66
63
69
62
63
62
63
68
69
65
71
63
66
55
63
65
64
62
67
60
65
53
60
62
61
60
64
58
59
47
55
55
53
52
57
52
57
NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).
A--WEIGHTED SOUND POWER WITH SOUND HOOD
UNIT SIZE
18--- 30
24--- 30
30--- 30
36--- 31, 51, 61
42--- 30
48--- 30, 50, 60
60--- 30
60--- 50, 60
STANDARD
RATING
68
74
77
76
74
79
73
76
125
47
47
52
52
50
54
51
52
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
250
500
1000
2000
4000
48
56
61
55
52
57
59
62
61
58
62
67
67
65
62
62
66
67
64
60
61
63
64
61
58
66
69
70
67
64
64
62
63
59
56
62
63
66
65
59
8000
46
51
54
52
49
56
49
57
NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- SERIES
18--- 30
24--- 30
30--- 30
36--- 31
36--- 51, 61
42--- 30
48--- 30, 50, 60
60--- 30, 50, 60
REQUIRED SUBCOOLING ° F (° C)
11 (6.1)
11 (6.1)
10 (5.6)
10 (5.6)
11 (6.1)
10 (5.6)
14 (7.8)
15 (8.3)
HP ONLY REPLACEMENT WITH PISTON INDOORS
When the 25HCE4 is used as a replacement component in a system with a piston fan coil, use the indoor piston size specified below:
UNIT SIZE
18
24
30
36
42
48
60
PISTON SIZE
FFM
0.050
0.057
0.070
0.072
FB4CNF
0.052
0.057
0.067
0.070
0.078
0.084
= N/A
8
FPMA
0.050
0.056
0.067
0.069
9
0
0
0
1
1
1
0
0
0
0
0
0
0
25HCE418A0030011
25HCE424A0030011
25HCE430A0030011
25HCE436A0031011
25HCE436A0051011
25HCE436A0061011
25HCE442A0030011
25HCE448A0030011
25HCE448A0050011
25HCE448A0060011
25HCE460A0030011
25HCE460A0050011
25HCE460A0060011
18
24
30,36,42,48,60
-
UNIT SIZE
SERIES
UNIT
792.5
31 3/16
Y=YES
N=NO
N
23 1/8
25 3/4
31 3/16
35
"X"
587.3
654.0
792.5
889.0
MINIMUM GROUND MOUNTING
PAD APPLICATION DIMENSIONS
Y
N
N
INCH
17
20
22
26
7/8
7/16
15/16
3/4
"Y"
32 1/16
32 1/16
32 1/16
28 11/16
28 11/16
28 11/16
38 7/8
28 11/16
28 11/16
28 11/16
32 1/16
35 1/2
35 1/2
B
MM
815.1
815.1
815.1
728.7
728.7
728.7
987.8
728.7
728.7
728.7
815.1
901.4
902.0
454.6
518.5
583.2
679.7
MINIMUM ROOF-TOP MOUNTING
PAD APPLICATION DIMENSIONS
792.5
31 3/16
N
N
792.5
31 3/16
N
N
792.5
31 3/16
N
792.5
Y
792.5
31 3/16
N
N
31 3/16
N
N
792.5
31 3/16
N
N
792.5
31 3/16
N
Y
792.5
31 3/16
N
N
792.5
31 3/16
N
792.5
N
654.0
31 3/16
N
N
25 3/4
N
N
MM
587.3
INCH
A
23 1/8
N
N
208-230-1-60
Y
N
N
Y
N
N
N
Y
N
N
N
N
460-3-60
208/230-3-60
N
Y
N
N
Y
Y
N
N
Y
Y
Y
Y
ELECTRICAL
CHARACTERISTICS
DIMENSIONS
575-3-60
7/8
7/8
7/8
7/8
7/8
7/8
7/8
3/4
3/4
3/4
3/4
5/8
5/8
INCH
C
MM
22.2
22.2
22.2
22.2
22.2
22.2
22.2
19.1
19.1
19.1
19.1
15.9
15.9
INCH
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
6 9/16
4 7/16
4 7/16
D
MM
166.1
166.1
166.1
166.1
166.1
166.1
166.1
166.1
166.1
166.1
166.1
113.0
113.0
INCH
MM
626.3
626.3
626.3
626.3
626.3
626.3
626.3
626.3
626.3
626.3
626.3
539.9
459.0
INCH
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
9 1/8
7 13/16
F
MM
231.3
231.3
231.3
231.3
231.3
231.3
231.3
231.3
231.3
231.3
231.3
231.3
197.9
INCH
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
1 1/8
G
MM
28.2
28.2
28.2
28.2
28.2
28.2
28.2
28.2
28.2
28.2
28.2
28.2
28.2
INCH
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
3 13/16
NOTE: ALL DIMENSIONS IN INCH (MM)
24 11/16
24 11/16
24 11/16
24 11/16
24 11/16
24 11/16
24 11/16
24 11/16
24 11/16
24 11/16
24 11/16
21 1/4
18 1/16
E
H
MM
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
97.4
INCH
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
27 7/8
25 1/4
I
MM
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
708.0
641.4
INCH
MM
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
847.7
708.0
641.4
36 5/8
36 5/8
36 5/8
33 1/4
33 1/4
33 1/4
43 1/2
33 1/4
33 1/4
33 1/4
36 5/8
40
40
INCH
K
MM
930.3
930.3
930.3
844.6
844.6
844.6
1104.9
844.6
844.6
844.6
930.3
1016.0
1016.0
212
212
212
197
197
197
201
170
170
170
158
144
136
Lbs
96.2
96.2
96.2
89.4
89.4
89.4
91.2
77.1
77.1
77.1
71.7
65.3
61.7
Kgs
OPERATING
WEIGHT
248
248
248
232
232
232
235
201
201
201
180
175
166
Lbs
112.5
112.5
112.5
105.2
105.2
105.2
106.6
91.2
91.2
91.2
81.6
79.4
75.3
Kgs
SHIPPING
WEIGHT
U.S. ECCN: Not Subject to Regulation (N.S.R.)
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
33 3/8
27 7/8
25 1/4
J
33 5/16
33 5/16
33 5/16
33 5/16
33 5/16
33 5/16
33 5/16
33 5/16
33 5/16
33 5/16
33 5/16
27 7/8
25 1/4
36 5/8
36 5/8
36 5/8
33 3/16
33 3/16
33 3/16
43 3/8
33 3/16
33 3/16
33 3/16
36 5/8
40
40
INCH
929.5
929.5
929.5
843.1
843.1
843.1
1102.2
843.1
843.1
843.1
929.5
1015.8
1015.8
MM
SHIPPING
HEIGHT
SD5367-4 REV. B
846.6
846.6
846.6
846.6
846.6
846.6
846.6
846.6
846.6
846.6
846.6
708.2
641.5
SHIPPING
LENGTH / WIDTH
(Sq.)
INCH
MM
TESTED AHRI COMBINATION RATINGS
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Carrier database at: www.MyCarrierRatings.com
For performance data at specific application &/or design conditions with various indoor unit combinations, the
equipment performance calculator can be accessed at : http://rpmob.wrightsoft.com/
High Temp
Model Number
Indoor Coil Model
Number
Cooling
Capacity
EER
SEER
E
Capacity
E COP
25HCE418A**30
FB4CNP018L
17,800
11.7
14
17,600
25HCE424A**30
FB4CNP030L
22,200
11.5
14
22,200
25HCE430A**30
FB4CNP030L
28,600
11.7
14
25HCE436A**31
FB4CNP036L
33,000
11.7
25HCE436A**51, 61
FB4CNP036L
33,000
25HCE442A**30
FB4CNP042L
25HCE448A**30, 50, 60
25HCE460A**30, 50, 60
Low Temp
HSPF
H
Capacity
H COP
3.72
8.2
10,400
2.40
3.84
8.2
13,200
2.54
28,600
3.62
8.2
17,100
2.44
14
33,800
3.62
8.2
21,000
2.40
11.0
14
33,000
3.64
8.2
20,800
2.46
40,000
11.5
14
41,000
3.62
8.2
25,200
2.50
FB4CNP048L
46,000
11.7
14
45,500
3.64
8.2
27,800
2.56
FX4DN(B,F)061L
57,000
11.7
14
54,500
3.70
8.2
33,000
2.56
Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit.
High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43° F (6_C) wb air entering outdoor unit.
Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (---8_C) db 15° F (---9_C) wb air entering outdoor unit.
COP — Coefficient of Performance
EER — Energy Efficiency Ratio
HSPF — Heating Seasonal Performance Factor
SEER — Seasonal Energy Efficiency Ratio
12
25HBC5
Comfort™ 15 Heat Pump
with Puronr Refrigerant
1---1/2 to 5 Nominal Tons
Product Data
OHP-10
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 15 SEER/ 12.5 EER / 8.0 -- 9.0 HSPF
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 69 dBA
S Sound levels as low as 68 dBA with accessory sound blanket
Comfort
S System supports Edger Thermidistatt or standard thermostat
controls
Reliability
the environmentally sound refrigerant
Carrier heat pumps with Puronr refrigerant provide a collection of
features unmatched by any other family of equipment. The 25HBC
has been designed utilizing Carrier’s Puron refrigerant. The
environmentally sound refrigerant allows consumers to make a
responsible decision in the protection of the earth’s ozone layer.
This product has been designed and manufactured to meet Energy
Starr criteria for energy efficiency when matched with appropriate
coil components. Refer to the combination ratings in the Product
Data for system combinations that meet Energy Starr guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.
S Puronr refrigerant -- environmentally sound, won’t deplete the
ozone layer and low lifetime service cost.
S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S High pressure switch
S Loss of charge switch
S Filter drier
S Balanced refrigeration system for maximum reliability
Durability
WeatherArmor Ultrat protection package:
S Solid, durable sheet metal construction
S Dense wire coil guard standard
S Baked--on powder paint
Applications
S Long--line -- up to 250 feet (76.20 m) total equivalent length, up
to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft.
(24.38 m) evaporator above condenser (See Longline Guide for
more information.)
S Low ambient cooling (down to --20_F/--28.9_C) with accessory
kit
MODEL NUMBER NOMENCLATURE
1
N
2
N
3
A
4
A
5
A/N
6
N
7
N
8
N
9
A/N
10
A/N
11
A/N
12
N
13
N
2
5
H
B
C
5
3
6
A
0
0
3
0
Product
Series
Product
Family
Tier
Major
Series
SEER
Grille
Variations
Open
Open
Voltage
Minor
Series
25 = HP
H = RES HP
0=Not
Defined
0=Not
Defined
3=208/230 ---1
B=Comfort C = Puron
Cooling
Capacity
5=15 SEER
A = Dense
0, 1, 2...
the environmentally sound refrigerant
25HBC5
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.
This product has been designed and manufactured to
meet Energy Star® criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.
STANDARD FEATURES
Feature
18
24
30
36
42
48
60
Puron Refrigerant
X
X
X
X
X
X
X
15.3
15.3
15.3
15.3
15.0
15.0
15.0
Scroll Compressor
X
X
X
X
X
X
X
Field Installed Filter Drier
X
X
X
X
X
X
X
Front Seating Service Valves
X
X
X
X
X
X
X
Internal Pressure Relief Valve
X
X
X
X
X
X
X
Internal Thermal Overload
X
X
X
X
X
X
X
Long Line capability
X
X
X
X
X
X
X
Low Ambient cooling capability with Kit
X
X
X
X
X
X
X
Suction Line Accumulator
X
X
X
X
X
X
X
High Pressure Switch
X
X
X
X
X
X
X
Loss of Charge Switch
X
X
X
X
X
X
X
Dense Grille
X
X
X
X
X
X
X
Maximum SEER Rating*
X = Standard
* = Based on tested combination
2
PHYSICAL DATA
18--- 30
24--- 30
30--- 30
36--- 30
169 (76.7)
200 (90.8)
196 (88.9)
215 (97.5)
Shipping Weight lb (kg)
207 (93.9)
233
(105.7)
242
(109.8)
Compressor Type
REFRIGERANT
Control
Charge lb (kg)
Outdoor Heating Piston #
5.6 (2.54)
42
Operating Weight lb (kg)
COND FAN
Air Discharge
Air Qty (CFM)
Motor HP
Motor RPM
COND COIL
Face Area (Sq ft)
Fins per In.
Rows
Circuits
VALVE CONNECT. (In. ID)
Vapor
Liquid
REFRIGERANT TUBES (In. OD)
Rated Vapor*
Liquid
42--- 30
245
(111.1)
290
(131.5)
48--- 30
260
(117.9)
303
(137.4)
60--- 30
294 (113.4)
7.60 (3.45)
46
257
(116.6)
Scroll
Puron (R---410A)
TXV (Puron Hard Shutoff)
7.00 (3.18)
7.40 (3.34)
8.90 (4.04)
52
61
61
9.60 (4.35)
67
12.50 (5.67)
76
2233
1/12
800
3223
1/12
800
Propeller Type, Direct Drive
Vertical
3223
3810
3810
1/12
1/5
1/5
800
800
800
4046
1/4
800
4046
1/4
800
15.09
20
1
4
20.12
20
1
5
20.12
20
1
5
22.63
20
1
6
17.60
20
2
7
17.60
20
2
7
25.15
20
2
9
5/8
5/8
3/4
3/4
3/8”
7/8
7/8
7/8
5/8
5/8
3/4
3/4
3/8
7/8
7/8
1 1/8
345 (156.5)
*Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for HP systems with Puron refrigerant:
Vapor Line Sizing and Cooling Capacity Losses -- Puronr Refrigerant 1-- Stage Heat Pump Applications
Unit
Nominal
Size (Btuh)
18,000
1--- Stage
HP with
Puron
24,000
1--- Stage
HP with
Puron
30,000
1--- Stage
HP with
Puron
36,000
1--- Stage
HP with
Puron
42,000
1--- Stage
HP with
Puron
48,000
1--- Stage
HP with
Puron
60,000
1--- Stage
HP with
Puron
Maximum
Liquid Line
Diameters
(In. OD)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line
Diameters
(In.) OD
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
Standard
Application
26--- 50
51--- 80
Long Line Application Requires Accessories
81--- 100
101--- 125
126--- 150
151--- 175
176--- 200
201--- 225
226--- 250
(7.9--- 15.2)
(15.5--- 24.4)
(24.7--- 30.5)
(30.8--- 38.1)
(38.4--- 45.7)
(46.0--- 50.3)
(53.6--- 60.0)
(61.3--- 68.6)
(68.9--- 76.2)
1/2
1
2
3
4
6
7
8
9
10
5/8
0
0
1
1
1
2
2
3
3
5/8
0
1
1
2
3
3
4
4
5
3/4
0
0
0
0
1
1
1
1
1
5/8
1
2
3
3
4
5
6
7
8
3/4
0
0
1
1
1
2
2
2
3
7/8
0
0
0
0
1
1
1
1
1
5/8
1
2
4
5
6
7
9
10
11
3/4
0
0
1
1
2
2
3
3
4
7/8
0
0
0
0
1
1
1
1
2
3/4
0
1
2
2
3
4
4
5
6
7/8
0
0
1
1
1
2
2
2
3
3/4
0
1
2
3
4
5
5
6
7
7/8
0
0
1
1
2
2
2
3
3
3/4
1
2
4
5
6
7
9
10
11
7/8
0
1
2
2
3
4
4
5
5
1 ---1/8
0
0
0
1
1
1
1
1
1
Standard Length = 80 ft. (24.4 m) or less total equivalent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
3
25HBC5
UNIT SIZE SERIES
ELECTRICAL DATA
UNIT SIZE
V/PH
OPER VOLTS*
MAX
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
48--- 30
60--- 30
208/230/1
253
COMPR
FAN
MIN
LRA
RLA
FLA
197
48.0
58.3
73.0
79.0
109.0
117.0
134.0
9.0
12.8
14.1
16.7
21.1
21.8
26.4
0.5
0.5
0.5
1.2
1.2
1.2
1.2
MIN WIRE
SIZE†
MCA
MAX LENGTH
ft (m))‡
60° C
75° C
60° C
75° C
14
14
14
12
10
10
8
14
14
14
12
10
10
10
67 (20.4)
48 (14.6)
44 (13.4)
57 (17.4)
72 (21.9)
70 (21.3)
91 (27.7)
63 (19.2)
45 (13.7)
41 (12.5)
54 (16.5)
69 (21.0)
67 (20.4)
56 (17.1)
11.8
16.5
18.1
22.1
27.6
28.5
34.2
MAX
FUSE**
or BRK
AMPS
20
25
30
35
40
40
50
25HBC5
*
{
Permissible limits of the voltage range at which the unit will operate satisfactorily
If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70). The ampacity of non ---metallic---sheathed cable (NM),
trade name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or 75_C
insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA
70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1
A--WEIGHTED SOUND POWER (dBA)
UNIT SIZE
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
48--- 30
60--- 30
STANDARD
RATING
dBA
73
69
71
72
74
74
74
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125
250
500
1000
2000
4000
8000
49.5
48.5
51.0
55.5
56.5
55.5
59.0
60.0
59.5
58.5
59.5
64.0
62.0
62.0
65.0
61.5
61.5
63.5
67.0
66.0
65.0
69.0
62.5
65.5
66.5
68.5
69.0
68.0
65.5
61.0
62.5
64.5
65.0
65.0
65.0
62.0
59.0
60.0
61.5
62.0
62.0
62.5
55.0
53.5
53.5
55.5
57.5
56.0
62.0
NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).
A--WEIGHTED SOUND POWER (dBA) WITH SOUND SHIELD
UNIT SIZE
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
48--- 30
60--- 30
STANDARD
RATING
dBA
72
68
69
70
72
72
73
TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)
125
250
500
1000
2000
4000
8000
50.5
49.5
50.5
54.5
56.5
55.5
58.5
60.0
58.5
58.5
57.5
64.5
62.5
62.5
65.0
61.5
61.5
63.0
66.5
66.0
65.0
67.5
62.0
64.0
66.0
66.5
68.0
67.0
64.5
61.0
61.5
64.0
64.5
64.0
64.0
61.5
58.5
58.5
61.0
61.0
60.0
61.0
53.5
51.5
51.5
54.0
54.5
53.0
56.5
NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- SERIES
18--- 30
24--- 30
30--- 30
36--- 30
42--- 30
48--- 30
60--- 30
REQUIRED SUBCOOLING ° F (° C)
12 (6.7)
14 (7.8)
10 (5.6)
8 (4.4)
10 (5.6)
11 (6.1)
10 (5.6)
8
9
0
0
0
0
0
0
25HBC524
25HBC530
25HBC536
25HBC542
25HBC548
25HBC560
18
O
O
O
O
O
O
O
O
O
O
O
O
O
O
32 5/16"
35 3/4"
28 15/16"
28 15/16"
39 1/8"
35"
35"
35"
35"
35"
3 1/2"
26" X 26"
31 1/2" X 31 1/2"
35" X 35"
MINIMUM
VAPOR
LINE CONN.
D
C
3/8"
X = YES
O = NO
32 5/16"
35"
B
28 15/16"
31 3/16"
7/8" HOLE WITH
1 1/8" KNOCKOUT
FIELD CONTROL
SUPPLY CONN.
7/8" HOLE
O
X
O
O
O
O
O
O
208-230-1-60
X
X
X
X
X
X
230-1-60
UNIT SIZE
B
0
ELECTRICAL
SERIES
CHARACTERISTICS A
25HBC518
208/230-3-60
UNIT
DIMENSIONS -- ENGLISH
460-3-60
C
7/8"
7/8"
7/8"
3/4"
3/4"
5/8"
SQ.
A
D
5/8"
AIR DISCHARGE
3 7/8"
3 7/8"
3 7/8"
3 3/4"
3 3/4"
3 3/4"
3 3/4"
E
6 9/16"
6 9/16"
6 9/16"
6 9/16"
6 9/16"
6 9/16"
6 9/16"
F
28 7/16"
28 7/16"
28 7/16"
28 7/16"
28 7/16"
28 7/16"
24 11/16"
G
1 7/8"
9 1/8"
9 1/8"
9 1/8"
9 1/8"
9 1/8"
9 1/8"
9 1/8"
K
P
L
AIR IN
5/8"
5/8"
5/8"
1/2"
1/2"
1/2"
1/2"
M
1 1/8"
17 1/4"
16 3/4"
17"
15 3/4"
16 1/4"
15 3/4"
16"
N
K
M
G
16 1/4"
16 1/4"
16 3/4"
16 3/4"
16"
16 3/4"
15"
3/8" TIEDOWN KNOCKOUTS
(2) PLACES
L
3 13/16"
2 15/16"
2 15/16"
2 15/16"
2 13/16"
2 13/16"
2 13/16"
2 13/16"
P
345
303
290
257
242
233
207
SHIPPING
AIR IN
AIR IN
AIR
DISCHARGE
E
N
F
F, MAX. 125
2. MINIMUM OUTDOOR
OPERATING AMBIENT IN COOLING
MODE IS 55
AIR IN
1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT,
48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE,
AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
NOTES:
294
260
245
215
196
200
169
OPERATINGSHIPPING
WEIGHT (lbs)
WEIGHT (lbs)
25HBC5
18 1/4"
14"
14 3/4"
17"
15 1/2"
16 1/2"
14"
TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Carrier database at:
http://cactaxcredits.info/carrier-ratings/ac_ratings_srch.php
Equipment performance calculator can be accessed at: http://rpmob.wrightsoft.com/
Coil Model Number
25HBC518A**30
25HBC524A**30
25HBC530A**30
25HBC536A**30
25HBC542A**30
25HBC548A**30
25HBC560A**30
FX4DNF019
FX4DNF025
FX4DN(B,F)031
FX4DN(B,F)037
FX4DN(B,F)043
FX4DN(B,F)049
FX4DN(B,F)061
Furnace
Model Number
Cooling
Capacity
EER
SEER
17,800
24,000
28,800
34,800
41,500
47,500
57,000
12.6
12.5
12.5
12.5
12.5
12.5
12.5
15.3
15.3
15.3
15.0
15.0
15.0
15.0
High Temp
E
E COP
Capacity
17,800
3.92
24,000
3.96
28,600
3.98
35,400
3.92
41,500
3.82
46,500
3.84
57,000
3.86
HSPF
8.6
8.7
8.7
8.7
8.7
8.5
8.7
Low Temp
H
H COP
Capacity
10,700
2.60
14,700
2.68
17,000
2.66
21,400
2.64
26,400
2.62
29,000
2.66
35,400
2.72
* AHRI = Air Conditioning, Heating & Refrigeration Institute
Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit.
High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43° F (6_C) wb air entering outdoor unit.
Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (---8_C) db 15° F (---9_C) wb air entering outdoor unit.
COP — Coefficient of Performance
EER — Energy Efficiency Ratio
HSPF — Heating Seasonal Performance Factor
SEER — Seasonal Energy Efficiency Ratio