User Manual Weighing Indicator
User Manual
Weighing Indicator
BTW
Table of Contents
Instructions for Use ........................................................................................................................... 2
Preparing to Use the Scale .............................................................................................................. 2
Chapter 1 Introduction ...................................................................................................................... 4
1-1 Features ................................................................................................................................... 4
1-2 Specifications .......................................................................................................................... 4
1-3 Display...................................................................................................................................... 4
1-4 Keypad Functions Description.............................................................................................. 5
1-5 Power Supply .......................................................................................................................... 5
1-6 Error Massage ........................................................................................................................ 5
Chapter 2 Operating Introduction ................................................................................................... 6
2-1 Keypad Operating................................................................................................................... 6
2-2 Self Test Mode ........................................................................................................................ 7
2-3 General Function Operating ................................................................................................. 8
2-3-1 Simple Counting Function ............................................................................................. 9
2-3-2 Check Weighing Function ............................................................................................10
2-3-3 Accumulation Function.................................................................................................. 11
2-3-4 Hold Function .................................................................................................................12
2-4 Further Function Operating.................................................................................................13
2-4-1 General Setting .............................................................................................................13
2-4-2 Check Voltage ...............................................................................................................13
2-4-3 External Weight Calibration .........................................................................................14
2-4-4 Transmission Setting ....................................................................................................15
Appendix 1 7-Segment Display Characters ................................................................................17
Appendix 2 Installation ...................................................................................................................18
02023032/02023042
1
ZSME3000000319
Thank for your purchasing of our Weighing Scale. To
guide you to use our product correctly, please read
this User Manual carefully to extend the life of
machine and to avoid error.
Instructions for Use
1. Please keep scale in a cool and dry place. Do not store under high temperatures.
2. Please keep the scale clean and free from insect infestation.
3. Avoid impacting with other items or overloaded with excessively heavy weights.
(The load must not exceed the maximum capacity of the scale).
4. If the scale is not going to be used for some time, please clean it and store it in a plastic
bag in dry condition. A desiccant sachet may be included to prevent moisture from
building up.
5. Please operate or charge the scale in an open area. Do not squeeze the power cord to
avoid wire on fire.
6. Any suggestion is warmly welcome.
Preparing to Use the Scale
1. Locate the scale on a firm level surface free from vibrations for accurate weight readings.
Adjust the four leveling feet to centre the leveling bubble on the scale.
2. Avoid hot sunshine directly on the scale or near the exhaust port of ventilating system.
3. Please use a separate power source plug, to avoid the disturbance of other electric
appliance.
4. There should be no weight on the scale when power is turned on.
5. Commodity should be placed at the centre of platter when being weighed, and its size
should not exceed the dimension of the platter.
6. We suggest to warm the scale for 15 ~ 20 minutes before using.。
7. Please note that when
symbol shows up on the display, which means the indicator
needs to be charged. The indicator could only operate for another 6~8 hours. Then
“ .
. ” will show on the display and the indicator must be fully charged before
operating again.
8. Introduction of Storage Battery
02023032/02023042
2
ZSME3000000319
Due to the storage battery adopt the advanced free-maintaining technique, customers need
not to replenish electrolyte.
The scale should be recharged every 3 months to prevent failure of the internal
rechargeable battery.
1. The battery should be charged for 8~10 hours.
2. The temperature of battery should below 45℃.
Maintaining
1. Please do not discharge with over-current when using the battery. Please charge the
battery after discharging current.
2. Please take down the battery when the scale is not used for a long time or break the
connection of cathode.
3. Do not short the battery terminals to check whether there is current. Please check
whether the connection point is firm to guarantee good connection.
4. The battery should be replaced by specialized person. No reverse-battery or the
product will be damaged.
a) Anode of battery should be connected with Anode of product battery(usually red
cable)
b) Cathode of battery should be connected with Cathode of product battery (usually
brown cable or black cable)
c) See the picture following
Brown cable(or black cable)
connected with Anode of
battery
Red cable connected with
Cathode of battery
Safety warnings
1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode.
2. The hydrogen will be resolved when using or charging the battery and it will cause
explosion when approaches fire.
No burning
Caution Corrosion
02023032/02023042
Warning explosion
3
Children faraway
ZSME3000000319
Chapter 1 Introduction
1-1 Features











The interface is simple and easy to operate
Up to 1/15,000 display resolution
High Speed 24bits AD
AC / DC switching function (Built-in rechargeable battery)
Low power indication
LCD display (Weight-6 digits); Full range tare; Auto zero tracking
Simple counting; Gross/Net indication; Hold function
Check mode Lo / Hi / OK with 3 selectable beeping sounds
Lo / Hi / OK indication shows on LED lights
Selectable unit: Kilogram (kg) and pound (lb)
Easily viewing single weight / total weight within 1 button press
Option:
 RS232: Bi-direction transmission, easy data reading or printing
 Sleeve connecting stand
1-2 Specifications
 Display LCD 6 digits, Height 25mm, LED Backlight
 Indicator Dimensions: 235 x 163 x 133 mm (W x H x D)
1-3 Display
● HI
● OK
● LO
1
● 7
2
3
4
5
6
Icon Introduction
→O← :
:
Net :
:
“Zero” indication
When the weight is negative, this icon appears.
Put container on the platter, after stable and press tare key and the “Net” appears.
“Low battery power” indication
kg
:
“kg” unit
lb
斤
:
:
“lb” unit
“Taiwan Tael“ unit
Pcs
:
Counting mode
%
HI
OK
LO
:
:
:
:
Percent indication
The weight is higher than setting value, “HI “LED on
When the weight is between HI limit values and LO limits value, “OK “LED on
The weight is lower than setting value, “LO “LED on
02023032/02023042
4
ZSME3000000319
▼ 1
:
▼ 2
:
▼ 3
:
“STABLE” indication
“GROSS” indication. When the object is in net mode and press F key, this icon
appears
“M+” indication
▼ 4
▼ 5
:
:
“PT” indication
Range 2
▼ 6
:
Range 1
●
:
When this LED is on, the indicator is charging.
7
1-4 Keypad Functions Description
key
Function
Hold the key for 1 sec.
Zero key
Check Voltage
Tare/Pre-tare key
 Backlight setting
 Zero display setting
 Local G value setting
Hold the key for 3 sec.
Enter password to enter
external weight calibration
Unit key
Function key
Print / transmit key
RS-232 transmission setting
1-5 Power Supply
Power Selection
6V 4Ah / 4V 4Ah rechargeable battery
110V/230V AC Adaptor
Power Consumption
White backlight: about DC 37.7 mA
Green backlight: about DC 12.95mA for 4V models; about DC 14.67mA
for 6V models
LED charging icon
When “ . . ” shown on the display, the indicator must be charged. When the charging
icon becomes red, it means the indicator is charging; when the charging icon becomes
green, it means the indicator is fully charged.
The indicator needs to be charged for about 8~9 hours when“ . . ” shown on the
display.
1-6 Error Massage
 The EEPROM is not working correctly.
(The EEPROM is not set yet, or the circuit on PCB is broken.)
 Zero is higher than the zero range when switching the indicator on.
 Zero is lower than the zero range when switching the indicator on.
 A/D value is unstable
 ADIC value is over the maximum range. (2097151 ~ -2097152)
 The weight of the object is over 9 divisions of the maximum capacity.
 The weight of the object is under -1/6 maximum capacity.
02023032/02023042
5
ZSME3000000319
Chapter 2 Operating Introduction
2-1 Keypad Operating
: Zero key
If the weighing value is within the range of zero balance, it can be re-zeroed and tare
cancelled.
: Tare key
It can be tare except when the weight is negative and the maximum capacity.
Tare Function
 Place the container onto the scale, until the weight value is stable, press
key for
zero return and the NET indication is shown on the display.
 Place the object into the container and the display shows the net weight value of the
object.
 Remove both object and container, and negative value of the container will show on the
display. Press
again to clear “tare value”. The scale returns to zero and NET
indication goes off.
 Tare can be continuously done until tare value=maximum capacity
 Continuous Tare  Press
key for continuous weight increase/decrease on platter.
 If there is Tare, the pre-tare cannot be done. If there is pre-tare first, and the tare weight
Is more than pre-tare weight, Tare can be done.
 No Tare can be done under gross weight display mode.
Pre-Tare Function
When there is nothing on the platter, press
key and use keypad to input pre-tare weight.
When the cursor flashes on the last digit of display, press
key again to complete.
Method of clearing Pre-tare value: the same as the method of clearing tare value.
Pre-tare mode, keypad function as followed:
⇒ upward key
⇒ move cursor leftward
⇒ downward key
⇒ move cursor rightward
: Function key
 In weighing mode, use this key to shift among simple counting function, check weighing
function, accumulation function and hold function.
 In tare mode, use this key to shift between the “Net value” and the “Gross value”.
Shift between Net value and Gross value
 In the Tare mode, the “Net” icon shows up. Press F key, the screen displays the
“gross weight ” and when the ”GROSS” icon  shows up ,“Net” icon goes off. Press
1F key again the screen displays the “net weight ” and when the ”Net” icon shows up ,
the ”GROSS” icon  goes off .
When the screen displays the “gross weight” (the ”GROSS” icon  shows up), keys
except the F key, have no response.
02023032/02023042
6
ZSME3000000319
:Unit key
Use
key to select a unit as the display indicated.
 The selected unit will be memorized when you turn the indicator off. And the memorized
unit will appear after you turn on the indicator next time.
:Print key
In accumulation mode, if the parameter set as
or
transmission, it
transmits the format of simple mode or complete mode.
This key is the combination key. while total counts is shown and weight returns to net zero,
press
key to clear data and RS-232 transmits the MC printing format.
 If there is new weight added on platter, a new data will be added to accumulation data. If
this weight is not taken off, nothing can be added to accumulation data. Display will
show the total counts for one second, then show net weight for one second, then the
display returns to the current weight.
 Clear Accumulation data: Press
key and the total counts shows on the display. Press
key again to clear accumulation data.
 Weight must return to net zero if to perform clear function
2-2 Self Test Mode
Press
key and not release. Then power on the indicator, Wait till display shows
to enter “Self-Test Mode”.
Press
Press
key
Press
key
Press
key
Press
key
Press
key
Press
key
Press
key
key
02023032/02023042
7
ZSME3000000319
INTERNAL VALUE MODE (must hook up full-bridge Load Cell to test)
 Press
to enter, and the display shows internal value
 Please check the internal value is within normal range(0~400000 no load)。
 Check whether the backlight is on
 Press
key to back to the last screen, the display shows
KEYPAD TEST MODE
 Press
to enter, display shows
 Keypad’s internal code:
 Press
key = 01、
key =31、
key=20、
key=30
key to back to the last screen, the display shows
FIRMWARE VERSION DISPLAY MODE
 Press
to enter, display shows the firmware version
 Press
key again, the display shows maintenance number
 Press
key to back to the last screen, display shows
for 2 seconds
BACK TO THE LAST SCREEN
Press
key to exit self-test mode, the scale will re-power on automatically
2-3 General Function Operating
Power on the indicator and enter into the setting that you set before or weighing mode.
Then press
to shift functions
kg
→0←
▼1
Press
.
Weighing Mode
▼6
key
→0←
▼1
Press
Pcs
Simple Counting Function
key
Check Weighing Function
Press
key
Accumulation Function
Press
key
Hold Function
Press
key
02023032/02023042
8
ZSME3000000319
2-3-1 Simple Counting Function
1. In weighing mode, press
key to enter into simple counting function.
2. Press
key to select sample quantity (10, 20, 50, 100, 200)
LCD shows as right picture:
→0←
▼1
Press
key
→0←
.
▼1
Press
key
→0←
.
Press
▼1
key
3. Select sample quantity and then place samples on the platter. After
stable, press
key and display shows ------. After stable, the scale
enters into counting mode and the display shows sample .
→0←
Pcs
▼1
Place samples
on the platter
.
▼1
Press
Pcs
After stable, ▼1
shows on
Pcs
Enter into counting
function
key
▼1
Press
key
kg
.
Display total weight
▼1
After 1 second
kg
.
Return to counting
mode after 1 second
4. Press
▼1
Display Unit weight
key to enter into next function.
02023032/02023042
9
ZSME3000000319
2-3-2 Check Weighing Function
1. In weighing mode, press
key twice to enter into check weighing function.
2. Press
key to enter into beeper setting.
LCD shows as right picture:
3. Press
key to select beep sound.
Press
⇒No beep
key
⇒OK (when the weight is
between Low limit & High
limit.), the beeper beeps.
⇒When the weight is under
or equal to Low limit & over
or equal to High limit, the
beeper beeps.
Beeper setting
Press
key
Press
key
Press
4. Press
5.
key
key to enter into Hi limit value setting
key⇒move cursor to right
(When the cursor arrive to the last
Digit, it returns to the first digit.)
key⇒increase/decrease number
Press
key
kg
key⇒confirm and enter into Lo
limit value setting
.
.
Hi limit value setting
6. In Lo limit value setting
key⇒confirm and return to
Beeper setting
Press
key
kg
.
Lo limit value setting
Press
key to
confirm and return
to Beeper setting
7. In beeper setting, press
key to enter
into check weighing function. When
the weight is more than 10d, check weighing function activates.
8. Press
Press
key
→0←
kg
▼1
key to exit the setting and
.
Check weighing
function
Shift “Hi,OK,LO “ LED light
Put weight (>10d) according Hi-Lo limit value
Repeat above steps to set this function again.
setting
kg
 Units can not be shift in check weighing
.
function. Please enter into weighing mode
● OK
▼1
to shift units
enter into next function.
02023032/02023042
10
ZSME3000000319
2-3-3 Accumulation Function
1. In weighing mode, press
key three times to enter into accumulation function.
LCD shows as following picture:
Press
Press
key to shift
Press
key
kg
→0←
.
▼1
key
→0←
Accumulation
function
▼6
kg
.
▼1
▼6
Put weight
On platter
Put weight
On platter
kg
kg
.
▼1
Press
.
▼6
key
▼1
▼6
▼1
Accumulate
automatically
kg
▼3
▼6
kg
Accumulation
counts
▼1
▼3
kg
.
kg
Accumulation
weight
.
Return to
▼1
▼3
accumulation
function after
0.5 second
⇒Manual accumulation: After the weight is stable, press
▼1
▼6
Accumulation
counts
After 0.5 second
After 0.5 second
Return to
accumulation
function after
0.5 second
Accumulation
function
▼3
▼6
▼6
Accumulation
weight
key to accumulate
and “M+” icon  shows up. It does the second accumulation, after the weight
returns to zero.
⇒Automatic accumulation: After the weight is stable, it accumulates automatically,
and “M+” icon  shows up. It does the second accumulation, after the weight
returns to zero.
 If it set as
,
or
transmission mode, RS-232 outputs printing
format while accumulating.
 The Minimum weight of accumulation: > 10d
 If the weight is unstable while accumulating,
→0←
kg In accumulation
display shows
.
.
function, there is
accumulation
▼3
▼6
▼1
2. Press
key to see accumulation counts
data.
and accumulation weight.
Press
key
→0←
kg
▼1
▼3
▼6
Accumulation
counts
after 0.5 second
→0←
Return to accumulation
function after 0.5 second
02023032/02023042
11
kg
.
▼1
▼3
▼6
Accumulation
weight
ZSME3000000319
kg
→0←
3. Clear accumulation data:
.
When there is no weight on the platter,
▼1 ▼3
press
key to display accumulation counts.
Press
key
Then press
key again to clear the data.
→0←
“M+” icon  goes off.
 If it set as
or
transmission mode,
▼1
▼3
RS-232 outputs MC printing format after data clear.
key
 Press
key for 2 seconds and the beeper beeps Press
→0←
3 times. The accumulation data is cleared and RS-232
does not output MC printing format. “M+” icon  goes off.
▼1
4. Press
key to exit the setting and enter into next function.
The original accumulation data still exist.
No weight on
the platter
▼6
kg
Accumulation
counts
▼6
kg
▼6
Clear accumulation
data
2-3-4 Hold Function
1. In weighing mode, press
key four times to enter into hold function.
2. Use
key to select
,
or
Then press
key to enter into Hold function.
When the weight is fixed, the beeper beeps.
Press
The weight is unlocked only after taking off
the weight and the weight returns to zero.
The weight is unlocked, when increase or
decrease the weight that is beyond the
Press
tolerance d.
 Calculate the average weight and fixed the
display. To unlock it, press
key to re-read
the weight.
Press
Press
key
Press
kg
→0←
.
▼1
Press
key
▼6
key
Press
key
key
Press
key
key
Press
key
key
d value: 2~50d
defaults: 5d
Weighing
mode
:Move to right
:adjust
:save
number
kg
→0←
▼1
.
▼6
calculate
average weight
Press
key to enter
into weighing
mode
Press
key
→0←
kg
▼1
.
3. Press
key to exit the setting
and enter into next function.
 Repeat above steps to set this function again.
02023032/02023042
12
ZSME3000000319
2-4 Further Function Operating
2-4-1 General Setting
 Upward key (0~9 digit ent ry)
 Downward key (0~ 9 digit entry)
Press
key to save. Press
key to exit without saving and return
to upper level or weighing mode.
kg
→0←
For entering values:
.
▼1
 Move cursor rightward
 Move cursor left ward
Press
key for 1 sec.
Backlight setting
Press
Zero display setting
key
Press
Local G value setting
key
Backlight setting
Press
key
.
Auto. Backlight
Press
key
Press
key
Use
or
to enter parameter
.
Press
keys in order
.
Backlight on
Press
key
Press
Enter local G
value
key
.
.
Backlight off
After selection
Press
Press
key
key
Fail
Restart automatically
 Zero display setting: 0~9, when the weight is within +/- of the set values, it display as zero.
 Local G value conditions: The new Local G values must be within ±10% of the Local G
value set in the factory.
 If the external weight calibration has been used, the Local G value is disable.
 To enable it, please switch the jumper SWA1 to ADJ position first. Then do Weight
Calibration Setting
(See 3-2-1).
→0←
2-4-2 Check Voltage
.
▼1
In weighing mode and the weight returns to zero,
Weighing mode
▼6
Press
key
for 1 second
Press
key for 1 second to check voltage.
It returns to weighing mode after 3 second.
Returns to weighing
mode after 3 second
02023032/02023042
kg
13
.
Voltage
ZSME3000000319
2-4-3 External Weight Calibration
In weighing mode and the weight returns to zero, Press
key for 3 second to enter into
password display. Press
keys in order a nd enter into External Weight
Calibration. Otherwise it will returns to weighing mode.
kg
→0←
▼1
.
▼6
Press
key
for 3 seconds
Press
keys in order
The display shows the
calibration value and unit.
The right digit keeps
flashing.
kg
.
Press
key to
move the cursor to
the left.
kg
.
Press
key while
there is no load on
platter.
Press
key to
abort zero calibration
kg
The scale is managing
the data of zero point
When it becomes stable,
the display shows the
calibration weight.
2 seconds later
kg
.
While no load, press
key
and then press
key to
abort full capacity calibration
Put the weight on the
platter and press
key.
The scale is managing
the data of full capacity.
When it becomes stable,
the beeper beeps 3 times.
2 seconds later
Weight calibration
finished and then
take off the weight
Press
key return
to the weighing mode
→0←
kg
▼1
After aborting zero calibration, please put full
weight on the platter and wait till the scale
stable. Then it will calibrate automatically.
.
▼6
 Weight calibration conditions:
The calibration weight value placed on the platter must be over 100e, and the standard
deviation of the weight must be within ±10%.
02023032/02023042
14
ZSME3000000319
2-4-4 Transmission Setting
1. In weighing mode, press
2. Press
key for 1 second to enter into transmission setting.
key to select transmission
No transmission
Stable transmission
Continuous transmission Press
Press
key to transmit
→0←
kg
.
Weighing mode
▼6
▼1
for 1 sec
Press
key
(Simple mode)
Press
key to transmit
(Complet e mode)
Press
 Stable transmission
key
Press
key
Press
key
The format is as same
as
3. Press
key to set baud rate
(1200, 2400, 4800, 9600 or
19200.)
Press
Press
key
key
Press
4. Press
key to save the setting and
return to weighing mode
Press
Baud rate setting
key
→0←
kg
.
▼1
 RS-232 Output Format
The output format of
GROSS
Net
Plus OL
Minus OL
Unstable
S
S
O
O
U
T
T
L
L
S
,
,
,
,
,
G
N
G
G
G
S
T
S
S
S
key
▼6
Save the setting and
return to weighing mode
and
,
,
,
,
,
+
+
+
+
1
.
SP
SP
1
2
2
SP
SP
2
3
4
3
.
SP SP
SP SP
3
4
5
6
4
5
SP SP
SP SP
.
5
7
6
SP
SP
6
SP
t
SP
SP
SP
SP o
l
.
SP SP
SP SP
SP l
z
g
SP CR
SP
b
LF
Stable transmission:when the weight is more than 10d and the weight is stable,
it transmit above format. It transmits next data format only when take off the
weight on the platter and put it on again.
Continuous transmission:It always transmit above format.
Output rate: 4counts / second
02023032/02023042
15
ZSME3000000319
Press key to transmit (simple mode):use in accumulation mode.
Steps: 1. Press F key and select
. Press
key to enter into weighing
mode.
2. Select
and necessary baud rate.
3. Put the objects on the platter. After the weight stable, press
key to
accumulate the data and print out the order and the net value of the data as
following example.
4. Repeat above step to accumulate and print continuously.
5. Press
key twice to print TOTAL as following example and clear the data.
S/N
WT
--------------------------------------0001
2.500
 Press
key
0002
2.500
 Press
key
0003
2.500
 Press
key
--------------------------------------0003
7.500
 Press
key twice to print TOTAL
Press key to transmit (complete mode):use in accumulation mode.
Steps: 1. Press F key and select
. Press
key to enter into weighing
mode.
2. Select
and necessary baud rate.
3. Put the objects on the platter. After the weight stable, press
key to
accumulate the data and print out the data as following example.
TICKET NO. 0001
GS
2.500kg
TR
0.000kg
NT
2.500kg
 Press
key
4. Repeat above step to accumulate and record.
5. Press
key twice to print TOTAL as following example and clear the data.
TOTAL NUMBER
OF TICKETS 0003
TOTAL WEIGHT
2.500kg
 Press
key twice to print TOTAL
Stable transmission (the format is as same as
) in accumulation
mode.
Steps: 1. Press F key and select
. Press
key to enter into weighing
mode.
2. Select
and necessary baud rate.
3. Put the objects on the platter. After the weight stable, it automatically
accumulates the data and print out the order and the net value of the data as
following example.
4. Repeat above step to record and print continuously.
5. Press
key twice to print TOTAL as following example and clear the data.
02023032/02023042
16
ZSME3000000319
Appendix 1 7-Segment Display Characters
Number
Display
Letter
Display
Letter
0
A
N
1
B
O
2
C
P
3
D
Q
4
E
R
5
F
S
6
G
T
7
H
U
8
I
V
9
J
W
K
X
L
Y
M
Z
02023032/02023042
17
Display
ZSME3000000319
Appendix 2 Installation
1. Please connect the Load Cell and Indicator as following
5PIN Connector
PIN 1 E+
PIN 2 E3 4
PIN 3 S+
2
5
1
PIN 4 SPIN 5 GND
2. Connecting way of a 9 pin RS-232 connector as following.
PIN 2:Data inputting (TXD), position 2 in following picture
PIN 3:Data outputting (TXD), position 3 in following picture
PIN 5:Internal grounded (GND), position 5 in following picture
2
3
5
Relay Output
1. Principle of operation
Use check weighing function to set the ranges of High, OK, LOW.
If the weight is between the ranges of LOW, the data will output in LOW port;
If the weight is between the ranges of OK, the data will output in OK port;
If the weight is between the ranges of High, the data will output in High port;
 Please refer to check weighing function to set the ranges of High, OK, LOW.
2. Connecting ways and function
Terminal Block
Connector’s PIN
A1
PIN 1
B1
PIN 2
C1
PIN 3
COM
PIN 4
02023032/02023042
Function
High Output
OK Output
Low Output