Intel®Server Board S1200V3RP

Add to my manuals
271 Pages

advertisement

Intel®Server Board S1200V3RP | Manualzz

Intel

®

Technical Product Specification

Intel reference number G84364-004

Revision 2.0

June 2015

Revision History

Date

November 2012

May 2013

October 2013

January 2014

July 2014

November 2014

June 2015

1.2

1.3

1.4

2.0

Revision

Number

0.5

1.0

1.1

Revision History

Modifications

Preliminary release.

 Updated BIOS Setup Interface

 Changed the chipset of S1200V3RPL to C226

Updated Graphics Controller and Video output: Changed the supporting OS for pGFX Display Port video output to Microsoft Windows 7*.

Added Backup BIOS update instruction.

Updated TPM module information.

Updated Figure 9.

Added support for Intel

®

Xeon

®

processor E3-1200 v4 product family. ii Revision 2.0

Disclaimers

Disclaimers

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,

EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS

GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR

SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR

IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR

WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR

INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.

A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION

CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES,

SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH,

HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS'

FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL

INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR

NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF

THE INTEL PRODUCT OR ANY OF ITS PARTS.

Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information.

The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.

Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.

Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature.htm

Revision 2.0 iii

Table of Contents

Table of Contents

1.

Introduction ........................................................................................................................ 1

1.1

1.2

Chapter Outline ...................................................................................................... 1

Server Board Use Disclaimer ................................................................................. 2

2.

Overview ............................................................................................................................. 3

2.1

Intel

®

Server Boards S1200V3RP product family Feature Set ................................ 3

2.2

Server Board Layout .............................................................................................. 5

2.2.1

Server Board Connector and Component Layout ................................................... 5

2.2.2

Server Board Mechanical Drawings ....................................................................... 8

2.2.3

Server Board Rear I/O Layout .............................................................................. 11

3.

Functional Architecture ................................................................................................... 12

3.1

Processor Subsystem .......................................................................................... 13

3.1.1

Intel

®

Xeon

®

processor E3-1200 V3 product family............................................... 13

3.1.2

The 4 th

Generation Intel

®

Core

i3 Processors ..................................................... 14

3.2

3.3

Processor Function Overview ............................................................................... 14

Integrated Memory Controller (IMC) and Memory Subsystem .............................. 15

3.3.1

Supported Memory ............................................................................................... 16

3.3.2

Memory RAS Features ......................................................................................... 18

3.3.3

Post Error Codes .................................................................................................. 19

3.3.4

Processor Integrated I/O Module (IIO) .................................................................. 19

3.3.5

Intel

®

Integrated RAID Option ............................................................................... 21

3.3.6

Optional I/O Module Support ................................................................................ 21

3.3.7

Intel

®

I/O Acceleration Technolgy 2 (Intel

®

I/O AT2) ............................................. 22

3.4

Intel

®

C220 series Chipset PCH Functional Overview .......................................... 22

3.4.1

Digital Media Interface (DMI) ................................................................................ 23

3.4.2

PCI Express* Interface ......................................................................................... 23

3.4.3

Serial ATA (SATA) Controller ............................................................................... 23

3.4.4

Low Pin Count (LPC) Interface ............................................................................. 24

3.4.5

Serial Peripheral Interface (SPI) ........................................................................... 25

3.4.6

Universal Serial Bus (USB) Controller .................................................................. 25

3.4.7

Gigabit Ethernet Controller ................................................................................... 26

3.4.8

Enhanced Power Management ............................................................................ 27

3.4.9

Serial Ports .......................................................................................................... 27

3.4.10

KVM/Serial Over LAN (SOL) Function .................................................................. 27

3.4.11

System Management Bus (SMBus* 2.0) .............................................................. 28

3.4.12

Intel

®

Virtualization Technology for Direct I/O (Intel

®

VT-d) ................................... 28

3.5

Integrated Baseboard Management Controller (BMC) Overview .......................... 28

3.5.1

Super I/O Controller ............................................................................................. 30

3.5.2

Graphics Controller and Video Support ................................................................ 30

3.5.3

Baseboard Management Controller ...................................................................... 32 iv Revision 2.0

Table of Contents

4.

System Security ................................................................................................................ 34

4.1

4.2

BIOS Password Protection ................................................................................... 34

Trusted Platform Module (TPM) Support .............................................................. 35

4.2.1

TPM security BIOS ............................................................................................... 35

4.2.2

Physical Presence ................................................................................................ 36

4.2.3

TPM Security Setup Options ................................................................................ 36

4.3

Intel

®

Trusted Execution Technology .................................................................... 38

5.

Intel

®

Technology Support ............................................................................................... 39

5.1

5.2

5.3

Intel

®

Trusted Execution Technology .................................................................... 39

Intel

®

Virtualization Technology

– Intel

®

VT-x/VT-d/VT-c ...................................... 39

Intel

®

Intelligent Power Node Manager ................................................................. 40

5.3.1

Hardware Requirements ...................................................................................... 42

6.

Platform Management Functional Overview ................................................................... 43

6.1

Baseboard Management Controller (BMC) Firmware Feature Support................. 43

6.1.1

IPMI 2.0 Features ................................................................................................. 43

6.1.2

Non-IPMI Features ............................................................................................... 44

6.2

Basic and Advanced Features .............................................................................. 45

6.3

6.4

Advanced Configuration and Power Interface (ACPI) ........................................... 46

Power Control Sources ........................................................................................ 47

6.5

6.6

6.7

6.8

6.9

BMC Watchdog .................................................................................................... 47

Fault Resilient Booting (FRB) ............................................................................... 48

Sensor Monitoring ................................................................................................ 48

Field Replaceable Unit (FRU) Inventory Device ................................................... 49

System Event Log (SEL) ...................................................................................... 49

6.10

System Fan Management .................................................................................... 49

6.10.1

Thermal and Acoustic Management ..................................................................... 49

6.10.2

Thermal Sensor Input to Fan Speed Control ........................................................ 50

6.10.3

Fan Profiles .......................................................................................................... 51

6.10.4

Memory Thermal Throttling .................................................................................. 52

6.11

Messaging Interfaces ........................................................................................... 53

6.11.1

User Model ........................................................................................................... 53

6.11.2

IPMB Communication Interface ............................................................................ 54

6.11.3

LAN Interface ....................................................................................................... 54

6.11.4

Address Resolution Protocol (ARP) ...................................................................... 60

6.11.5

Internet Control Message Protocol (ICMP) ........................................................... 60

6.11.6

Virtual Local Area Network (VLAN) ...................................................................... 60

6.11.7

Secure Shell (SSH) .............................................................................................. 61

6.11.8

Serial-over-LAN (SOL 2.0) ................................................................................... 61

6.11.9

Platform Event Filter (PEF)................................................................................... 61

6.11.10

LAN Alerting ......................................................................................................... 62

6.11.11

Alert Policy Table ................................................................................................. 63

Revision 2.0 v

Table of Contents

6.11.12

SM-CLP (SM-CLP Lite) ........................................................................................ 63

6.11.13

Embedded Web Server ........................................................................................ 64

6.11.14

Virtual Front Panel ............................................................................................... 65

6.11.15

Embedded Platform Debug .................................................................................. 66

6.11.16

Data Center Management Interface (DCMI) ......................................................... 68

6.11.17

Lightweight Directory Authentication Protocol (LDAP) .......................................... 69

7.

Advanced Management Feature Support (RMM4) .......................................................... 70

7.1

Keyboard, Video, and Mouse (KVM) Redirection ................................................. 71

7.1.1

Remote Console .................................................................................................. 72

7.1.2

Performance ........................................................................................................ 73

7.1.3

Security ................................................................................................................ 73

7.1.4

Availability ............................................................................................................ 73

7.1.5

Usage .................................................................................................................. 73

7.1.6

Force-enter BIOS Setup ....................................................................................... 73

7.2

Media Redirection ................................................................................................ 73

7.2.1

Availability ............................................................................................................ 74

7.2.2

Network Port Usage ............................................................................................. 74

8.

On-board Connector/Header Overview ........................................................................... 76

8.1

Board Connector Information ............................................................................... 76

8.2

Power Connectors ................................................................................................ 77

8.3

System Management Headers ............................................................................. 78

8.3.1

Intel

®

Remote Management Module 4 Dedicated NIC Connector ......................... 78

8.3.2

TPM connector ..................................................................................................... 79

8.3.3

Intel

®

ESRT2 RAID Upgrade Key Connector ........................................................ 79

8.3.4

Local Control Panel Header ................................................................................. 79

8.3.5

HSBP_ I

2

C Header ............................................................................................... 80

8.3.6

HDD LED Header ................................................................................................. 80

8.3.7

Chassis Intrusion Header ..................................................................................... 80

8.3.8

SATA SGPIO Header ........................................................................................... 80

8.3.9

IPMB Connector ................................................................................................... 81

8.4

Front Panel Connector ......................................................................................... 81

8.4.1

Power/Sleep Button and LED Support ................................................................. 81

8.4.2

System ID Button and LED Support ..................................................................... 82

8.4.3

System Reset Button Support .............................................................................. 82

8.4.4

NMI Button Support .............................................................................................. 82

8.4.5

NIC Activity LED Support ..................................................................................... 83

8.4.6

Hard Drive Activity LED Support........................................................................... 83

8.4.7

System Status LED Support ................................................................................. 83

8.5

I/O Connectors ..................................................................................................... 83

8.5.1

VGA Connector .................................................................................................... 83

8.5.2

Display Port Connector ........................................................................................ 84 vi Revision 2.0

Table of Contents

8.5.3

SATA Connectors ................................................................................................ 84

8.5.4

Serial Port Connectors ......................................................................................... 84

8.5.5

USB Connector .................................................................................................... 85

8.5.6

I/O Module Connector .......................................................................................... 87

8.5.7

SAS Module Connector ........................................................................................ 88

8.5.8

NIC1 with USB2.0 connector ................................................................................ 89

8.5.9

NIC2 with USB3.0 connector ................................................................................ 89

8.6

Fan Headers ........................................................................................................ 90

9.

BIOS Setup Interface ........................................................................................................ 91

9.1

9.2

HotKeys Supported During POST ........................................................................ 91

POST Logo/Diagnostic Screen ............................................................................. 91

9.3

9.4

BIOS Boot Pop-up Menu ...................................................................................... 92

BIOS Setup Utility ................................................................................................ 92

9.4.1

BIOS Setup Operation .......................................................................................... 92

9.4.2

BIOS Setup Utility Screens................................................................................... 95

9.5

BIOS Update Capability ..................................................................................... 196

9.5.1

Standalone BIOS Flash Update ......................................................................... 197

9.5.2

OS-Running BIOS Flash Update ........................................................................ 198

9.5.3

BIOS Backup Flash Update ................................................................................ 199

9.6

BIOS Recovery .................................................................................................. 199

10.

Jumper Blocks ................................................................................................................ 202

10.1

10.2

10.3

BIOS Default Jumper Block ................................................................................ 203

BIOS Recovery Jumper ...................................................................................... 203

Password Clear Jumper Block ........................................................................... 204

10.4

Management Engine (ME) Firmware Force Update Jumper Block ..................... 205

10.5

BMC Force Update Jumper Block ...................................................................... 206

11.

Intel

®

Light Guided Diagnostics .................................................................................... 207

11.1

System ID LED ................................................................................................... 208

11.2

11.3

System Status LED ............................................................................................ 208

BMC Boot/Reset Status LED Indicators ............................................................. 210

11.4

11.5

Post Code Diagnostic LEDs ............................................................................... 210

5 Volt Stand-By Present LED ............................................................................. 211

12.

Environmental Limits Specification .............................................................................. 212

12.1

Processor Thermal Design Power (TDP) Support .............................................. 212

12.2

MTBF ................................................................................................................. 213

13.

Server Board Power Distribution .................................................................................. 214

13.1

DC Output Specification ..................................................................................... 214

13.1.1

Output Power/Currents ....................................................................................... 214

13.1.2

Cross Loading .................................................................................................... 215

13.1.3

Standby Output .................................................................................................. 215

13.1.4

Voltage Regulation ............................................................................................. 215

Revision 2.0 vii

Table of Contents

13.1.5

Dynamic Loading ............................................................................................... 216

13.1.6

Capacitive Loading ............................................................................................. 216

13.1.7

Grounding .......................................................................................................... 216

13.1.8

Residual Voltage Immunity in Standy mode ....................................................... 216

13.1.9

Common Mode Noise ......................................................................................... 217

13.1.10

Ripple/Noise ....................................................................................................... 217

13.1.11

Timing Requirements ......................................................................................... 217

Appendix A: Integration and Usage Tips ............................................................................ 220

Appendix B: Integrated BMC Sensor Tables ....................................................................... 221

Appendix C: POST Code Diagnostic LED Decoder ............................................................ 240

Appendix D: POST Code Errors ........................................................................................... 246

Appendix E: Supported Intel

®

Server Chassis .................................................................... 253

Glossary ................................................................................................................................ 254

Reference Documents .......................................................................................................... 257

viii Revision 2.0

List of Figures

List of Figures

Figure 1. Intel

®

Server Board S1200V3RP Layout....................................................................... 5

Figure 2. Intel

®

Server Board S1200V3RPL and S1200V3RPS Layout ....................................... 6

Figure 3. Intel

®

Server Board S1200V3RPO and S1200V3RPM Layout ...................................... 7

Figure 4. Intel

®

Server Board S1200V3RP

– Mounting Hole Locations ....................................... 8

Figure 5. Intel

®

Server Board S1200V3RP

– Major Connector Pin-1 Locations ........................... 9

Figure 6. Intel

®

Server Board S1200V3RP

– Primary Side Keepout Zone ................................. 10

Figure 7. Intel

®

Server Board S1200V3RP

– Second Side Keepout Zone ................................. 11

Figure 8. Intel

®

Server Board S1200V3RP Rear I/O Layout ...................................................... 11

Figure 9. Intel

®

Server Board S1200V3RP Functional Block Diagram ....................................... 13

Figure 10. Intel

®

Server Board S1200V3RP DIMM Slot Layout ................................................. 17

Figure 11. Functional Block Diagram

– Chipset Supported Features and Functions ................. 22

Figure 12. Integrated Baseboard Management Controller (BMC) Overview .............................. 29

Figure 13. Integrated BMC Functional Block Diagram ............................................................... 29

Figure 14. Setup Utility

– TPM Configuration Screen ................................................................ 37

Figure 15. Fan Speed Control Process ..................................................................................... 51

Figure 16. Intel

®

RMM4 Lite Activation Key Installation ............................................................. 70

Figure 17. Intel

®

RMM4 Dedicated Management NIC Installation .............................................. 71

Figure 18. NIC1 with USB2.0 connector .................................................................................... 89

Figure 19. NIC2 with USB3.0 connector .................................................................................... 89

Figure 20. Main Screen ............................................................................................................. 97

Figure 21. Advanced Screen ................................................................................................... 102

Figure 22. Processor Configuration Screen ............................................................................. 105

Figure 23. Memory Configuration Screen ................................................................................ 115

Figure 24. Mass Storage Controller Configuration Screen ...................................................... 119

Figure 25. PCI Configuration Screen ....................................................................................... 122

Figure 26. NIC Configuration Screen ...................................................................................... 127

Figure 27. Serial Port Configuration Screen ............................................................................ 134

Figure 28. USB Configuration Screen ..................................................................................... 137

Figure 29. System Acoustic and Performance Configuration Screen ...................................... 141

Figure 30. Network Stack Screen ............................................................................................ 144

Figure 31. Security Screen ...................................................................................................... 146

Figure 32. Server Management Screen .................................................................................. 151

Figure 33. Console Redirection Screen ................................................................................... 158

Figure 34. System Information Screen .................................................................................... 162

Figure 35. BMC LAN Configuration Screen ............................................................................. 166

Figure 36. Boot Option Screen ................................................................................................ 178

Figure 37. CDROM Order Screen ........................................................................................... 184

Figure 38. Hard Disk Order Screen ......................................................................................... 185

Figure 39. Floppy Order Screen .............................................................................................. 186

Revision 2.0 ix

List of Figures

Figure 40. Network Device Order Screen ................................................................................ 186

Figure 41. BEV Device Order Screen ...................................................................................... 187

Figure 42. Add EFI Boot Option Screen .................................................................................. 188

Figure 43. Delete EFI Boot Option Screen .............................................................................. 189

Figure 44. Boot Manager Screen ............................................................................................ 190

Figure 45. Error Manager Screen ............................................................................................ 191

Figure 46. Save & Exit Screen ................................................................................................ 193

Figure 47. Jumper Blocks (J2K6, J2K8, J2K9, J3K2, J3K6) .................................................... 202

Figure 48. On-Board LED Placement ...................................................................................... 207

Figure 49. Power Distribution Block Diagram .......................................................................... 214

Figure 50. Differential Noise test setup ................................................................................... 217

Figure 51. Output Voltage Timing ........................................................................................... 218

Figure 52. Turn On/Off Timing (Power Supply Signals) ........................................................... 219

Figure 53. POST Code Diagnostic LEDs................................................................................. 240

Figure 54. Processor Heatsink Installation .............................................................................. 253 x Revision 2.0

List of Tables

List of Tables

Table 1. Intel

®

Server Board S1200V3RP Feature Set ................................................................ 3

Table 2. UDIMM Support Guidelines ......................................................................................... 16

Table 3. Intel

®

Server Board S1200V3RP DIMM Nomenclature ................................................ 17

Table 4. Intel

®

Server Board S1200V3RP DIMM Maximum Configuration ................................. 17

Table 5. PCI Express* Speed Matrix for Each Configuration ..................................................... 20

Table 6. Supported Intel

®

Integrated RAID Modules .................................................................. 21

Table 7. Intel

®

Server Board S1200V3RP SATA Data Transfer Rate ........................................ 23

Table 8. Intel

®

Server Board S1200V3RP series USB Ports Allocation ..................................... 25

Table 9. External RJ45 NIC Port LED Definition ........................................................................ 26

Table 10. Video Modes ............................................................................................................. 30

Table 11. Video Mode ............................................................................................................... 31

Table 12. TPM Setup Utility

– Security Configuration Screen Fields ......................................... 37

Table 13. Intel

®

Intelligent Power Node Manager ...................................................................... 40

Table 14. Intel

®

Intelligent Power Node Manager 2.0 Capabilities and Features ....................... 41

Table 15. Basic and Advanced Features ................................................................................... 45

Table 16. ACPI Power States .................................................................................................... 46

Table 17. Power Control Initiators ............................................................................................. 47

Table 18. Fan Profiles ............................................................................................................... 51

Table 19. Messaging Interfaces ................................................................................................ 53

Table 20. Factory Configured PEF Table Entries ...................................................................... 62

Table 21. Diagnostic Data ......................................................................................................... 68

Table 22. Additional Diagnostics on Error ................................................................................. 68

Table 23. RMM4 Option Kits ..................................................................................................... 70

Table 24. Enabling Advanced Management Features ............................................................... 71

Table 25. Board Connector Matrix............................................................................................. 76

Table 26. Main Power Connector Pin-out (J9H1) ...................................................................... 77

Table 27. CPU Power Connector Pin-out (J9B1) ....................................................................... 78

Table 28. Power Supply Auxiliary Signal Connector Pin-out (J9C3) .......................................... 78

Table 29. Intel

®

RMM4 Dedicated NIC Module Connector Pin-out (J4C1) ................................. 78

Table 30. Intel

®

RMM4

– Lite Connector Pin-out (J4B1) ............................................................ 79

Table 31. TPM connector Pin-out (J8J1) ................................................................................... 79

Table 32. Intel

®

ESRT2 RAID Upgrade Key Connector Pin-out (J4A1) ..................................... 79

Table 33. LCP Header Pin-out (J1G1) ...................................................................................... 79

Table 34. HSBP_ I

2

C Header Pin-out (J2K4) ............................................................................ 80

Table 35. HDD LED Header Pin-out (J1G2) .............................................................................. 80

Table 36. Chassis Intrusion Header Pin-out (J1F1) ................................................................... 80

Table 37. SATA SGPIO Header Pin-out (J2K2) ........................................................................ 80

Table 38. IPMB Connector Pin-out (J2K1) ................................................................................ 81

Table 39. Front Panel 24-pin Connector Pin-out (J1E1) ............................................................ 81

Revision 2.0 xi

List of Tables

Table 40. Power/Sleep LED Functional States .......................................................................... 82

Table 41. NMI Signal Generation and Event Logging ................................................................ 82

Table 42. VGA Connector Pin-out (J7A1) .................................................................................. 83

Table 43. Display Port Connector Pin-out (J8A1) ...................................................................... 84

Table 44. SATA Connector Pin-out (J1K4, J1K1, J1K5, J1K2, J2K5, J2K3) .............................. 84

Table 45. External DB9 Serial A Port Pin-out (J9A1) ................................................................. 85

Table 46. Internal 9-pin Serial B Header Pin-out (J9A2) ............................................................ 85

Table 47. Internal USB2.0 Connector Pin-out (J1K3) ................................................................ 85

Table 48. Internal USB3.0 Connector Pin-out (J1J1) ................................................................. 86

Table 49. Pin-out of Internal Low-Profile USB Connector (eUSB) for Solid State Drive (J5K1) .. 86

Table 50. Internal Type A USB Port Pin-out (J1J4) ................................................................... 86

Table 51. I/O Module Connector Pin-out (J1C1) ........................................................................ 87

Table 52. I/O Module Connector Pin-out (J4J1) ........................................................................ 88

Table 53. SSI 4-pin Fan Header Pin-out (J7K1, J3K4, J8K1, J8K2, J8B1) ................................ 90

Table 54. POST HotKeys Recognized ...................................................................................... 91

Table 55. BIOS Setup Page Layout .......................................................................................... 93

Table 56. BIOS Setup: Keyboard Command Bar ...................................................................... 94

Table 57. Screen Map ............................................................................................................... 96

Table 58. Server Board Jumpers (J2K6, J2K8, J2K9, J3K2, J3K6) ......................................... 203

Table 59. System Status LED State Definitions....................................................................... 208

Table 60. BMC Boot/Reset Status LED Indicators .................................................................. 210

Table 61. Server Board Design Specifications ........................................................................ 212

Table 62. MTBF Estimate ....................................................................................................... 213

Table 63. Over Voltage Protection Limits ................................................................................ 214

Table 64. Loading Conditions .................................................................................................. 215

Table 65. Voltage Regulation Limits ........................................................................................ 215

Table 66. Transient Load Requirements ................................................................................. 216

Table 67. Capacitive Loading Conditions ................................................................................ 216

Table 68. Ripples and Noise ................................................................................................... 217

Table 69. Output Voltage Timing ............................................................................................. 218

Table 70. Turn On/Off Timing .................................................................................................. 218

Table 71. Integrated BMC Core Sensors................................................................................. 222

Table 72. POST Progress Code LED Example ....................................................................... 240

Table 73. POST Progress Codes ............................................................................................ 241

Table 74. MRC Progress Codes ............................................................................................. 243

Table 75. POST Progress LED Codes .................................................................................... 244

Table 76. POST Error Codes and Messages .......................................................................... 246

Table 77. POST Error Beep Codes ......................................................................................... 251

Table 78. Integrated BMC Beep Codes ................................................................................... 252

Table 79. Compatible Intel

®

Server Chassis P4000S family .................................................... 253 xii Revision 2.0

< This page intentionally left blank. >

List of Tables

Revision 2.0 xiii

Introduction

1. Introduction

This Technical Product Specification (TPS) provides board specific information detailing the features, functionality, and high-level architecture of the Intel

®

Server Board series S1200V3RP family.

Design-level information related to specific server board components and subsystems can be obtained by ordering External Product Specifications (EPS) or External Design Specifications

(EDS) related to this server generation. EPS and EDS documents are made available under

NDA with Intel and must be ordered through your local Intel representative. See the Reference

Documents section for a list of available documents.

1.1 Chapter Outline

This document is divided into the following chapters:

Chapter 1

– Introduction

Chapter 2

– Overview

Chapter 3

– Functional Architecture

Chapter 4

– System Security

Chapter 5

–Intel

®

Technology Support

Chapter 6

– Platform Management Functional Overview

Chapter 7

– Advanced Management Feature Support (RMM4)

Chapter 8

– On-board Connector/Header Overview

Chapter 9

– BIOS Setup Interface

Chapter 10

– Jumper Blocks

Chapter 11

– Intel

®

Light Guided Diagnostics

Chapter 12

– Environmental Limits Specifications

Chapter 13

– Server Board Power Distribution

Appendix A

– Integration and Usage Tips

Appendix B

– Integrated BMC Sensor Tables

Appendix C

– POST Code Diagnostic LED Decoder

Appendix D

– POST Code Errors

Appendix E

– Supported Intel

®

Server Chassis

Glossary

Reference Documents

Revision 2.0 1

Introduction

1.2 Server Board Use Disclaimer

Intel Corporation server boards support add-in peripherals and contain a number of high-density

Very Large Scale Integration (VLSI) and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.

2 Revision 2.0

Overview

2. Overview

The Intel

®

Server Board S1200V3RPL, S1200V3RPS, S1200V3RPO, and S1200V3RPM are monolithic printed circuit boards (PCBs) with features designed to support the pedestal or rack server markets. These server boards are designed to support the Intel

®

Xeon

®

processor E3-

1200 V3 product family and Intel

®

Xeon

®

processor E3-1200 V4 product family (only support

Intel

®

C226 Platform Controller Hub (PCH) chipset). Previous generation Intel

®

Xeon

® processors are not supported. Many of the features and functions of these four server boards are common. A board will be identified by name when a described feature or function is unique to it.

2.1 Intel

®

Table 1. Intel

®

Feature

Processor

Memory

Chipset

Description

 Support for one Intel

®

Xeon

®

processor E3-1200 V3 processor and Intel

®

Xeon

®

processor

E3-1200 V4 product family (only support Intel

®

C226 Platform Controller Hub (PCH) chipset) in an LGA 1150 Socket H3 package with Thermal Design Power up to 95W.

 5 GT/s point-to-point DMI 2.0 interface to PCH.

 Two memory channels, four memory DIMMs (Two memory DIMMs per channel).

 Support for 1333/1600 MT/s Unbuffered (UDIMM DDR3L ECC memory).

 No support for RDIMMs.

 No support for SODIMMs.

 No support for mixing ECC and non-ECC UDIMMs.

S1200V3RPO supports for Intel

®

C224 Platform Controller Hub (PCH) chipset.

S1200V3RPS supports for Intel

®

C222 Platform Controller Hub (PCH) chipset.

S1200V3RPL and S1200V3RPM support for Intel

®

C226 Platform Controller Hub (PCH) chipset.

Cooling Fan Support Support for:

 One processor fan (4-pin header).

 Three front system fans (4-pin headers).

 One rear system fan (4-pin header).

Add-in PCI Express*

Slots

Four expansion slots at most:

 Slot 7: PCI Express* Gen2 x1 electrical with x8 physical connector, from PCH.

 Slot 6: PCI Express* Gen3 x8 electrical with x16 physical connector, from processor.

 Slot 5: PCI Express* Gen2 x8 or x4 electrical with x8 physical connector, from processor.

 Slot 4: PCI Express* Gen2 x4 electrical with x8 physical connector, from PCH.

Slot/SKU

Slot 7

S1200V3RPL

Yes

Slot Population Per SKU

S1200V3RPS

Yes

S1200V3RPM

NA

S1200V3RPO

NA

Slot 6

Slot 5

Slot 4

Yes

Yes

Yes

Yes

Yes

Yes

Yes

NA

NA

Yes

NA

NA

Hard Drive and

Optical Drive Support

 Optical devices are supported.

S1200V3RPO supports four SATA connectors at 6Gbps and two SATA connectors at

3Gbps through six onboard SATA connectors.

Revision 2.0 3

Overview

Feature

RAID Support

Description

S1200V3RPL and S1200V3RPM support six SATA connectors at 6Gbps through six onboard SATA connectors.

S1200V3RPS supports two SATA connectors at 6Gbps and four SATA connectors at

3Gbps through six onboard SATA connectors.

 Intel

®

RSTe SW RAID through onboard SATA connectors provides SATA RAID 0/1/10/5.

 Intel

®

Embedded Server RAID Technology II through onboard SATA connectors provides

SATA RAID 0/1/10 and optional RAID 5 support provided by the Intel

®

RAID Activation

Key RKSATA4R5.

 S1200V3RPL, S1200V3RPO, and S1200V3RPM support one optional internal SAS module connector which supports Intel

®

SAS or ROC modules with the product code of

RMS25CB080, RMS25JB080, RMS25CB040, and RMS25JB040.

External (Back

Panel) I/O connections

Internal I/O connectors/ headers

Video Support

External connections:

 DB9 serial port A connection.

 One DB-15 video connector.

 Two RJ-45 NIC connectors for 10/100/1000 Mb connections through the two Intel

®

Ethernet Controller I210.

 Two USB 3.0 ports at the back of the board.

 Two USB 2.0 ports at the back of the board.

 One 2x10 pin USB 3.0 header, providing front panel support for two USB ports respectively on S1200V3RPL, S1200V3RPO, and S1200V3RPM.

 One 2x5 pin USB 2.0 headers, providing front panel support for two USB ports respectively.

 One internal 2x5 pin serial port B header.

 One internal Type-A USB 2.0 port.

 One 9 pin USB header for eUSB SSD.

 One 1x7 pin header for optional Intel

®

Local Control Panel support.

 One combined header consists of a 24-pin SSI-EEB compliant front panel header.

 Integrated 2D video controller.

 Dual monitor video mode is supported.

 16 MB DDR3 Memory.

 Only S1200V3RPM supports integrated graphics support for processors with Intel

®

Graphics Technology. The processor graphics contains generation 7.5 graphics core architecture. This enables substantial gains in performance and lower power consumption over previous generations. Up to 20 EUs are supported depending on the processor SKU.

The maximum resolution should be 3840x2160@60Hz, 24bpp.

LAN

Compatible Intel

®

Server Chassis

Two Gigabit Ethernet Ports through the two Intel

®

Ethernet Controller I210 PHYs.

Security Intel

®

TPM Module AXXTPME3 (Accessory Option).

Server Management

 Integrated Baseboard Management Controller, IPMI 2.0 compliant.

 Support for Intel

®

Remote Management Module 4 solutions (Optional except on

S1200V3RPS).

Form Factor

 Support for Intel

®

Remote Management Module 4 Lite solutions (Optional except on

S1200V3RPS).

 Support for Intel

®

System Management Software.

 Support for Intel

®

Intelligent Power Node Manager (Need PMBus*-compliant power supply). microATX 9.6”x9.6” compliant form factor.

Intel

®

Server Chassis P4000S for S1200V3RP.

4 Revision 2.0

2.2 Server Board Layout

Overview

Figure 1. Intel

®

2.2.1 Server Board Connector and Component Layout

The following figure shows the layout of the server board. Each connector and major component is identified by a number or letter, and a description is given in the figure below.

Revision 2.0 5

Overview

6

Figure 2. Intel

®

Revision 2.0

Overview

Figure 3. Intel

®

Revision 2.0 7

Overview

2.2.2 Server Board Mechanical Drawings

8

Figure 4. Intel

®

Revision 2.0

Overview

Revision 2.0

Figure 5. Intel

®

9

Overview

Figure 6. Intel

®

10 Revision 2.0

Overview

Figure 7. Intel

®

2.2.3 Server Board Rear I/O Layout

The following drawing shows the layout of the rear I/O components for the server board.

Revision 2.0

Figure 8. Intel

®

11

Functional Architecture

3. Functional Architecture

The architecture and design of the Intel

®

Server Board S1200V3RP is based on the Intel

®

C220 series chipset. The chipset is designed for systems based on the Intel

®

Xeon

®

processor in an

LGA 1150 Socket H3 package.

The Intel

®

Server Board S1200V3RPO uses Intel

®

C224 chipset. The Intel

®

Server Board

S1200V3RPS uses Intel

®

C222 chipset. The Intel

®

Server Board S1200V3RPL and

S1200V3RPM use Intel

®

C226 chipset.

The Intel

®

Xeon

®

Processor E3-1200 V3 and Intel

®

Xeon

®

processor E3-1200 V4 Processors are made up of multi-core processors based on the 22nm processor technology. The 4 th

Intel

®

Core

i3 Processors are made up of dual-core processors based on the 22nm processor technology.

This chapter provides a high-level description of the functionality associated with each chipset component and the architectural blocks that make up the server boards.

12 Revision 2.0

Functional Architecture

Figure 9. Intel

®

3.1 Processor Subsystem

The Intel

®

Server Board S1200V3RP supports the following processor:

Intel

®

Xeon

®

processor E3-1200 V3 product family

Intel

®

Xeon

®

processor E3-1200 V4 product family (only support Intel

®

C226 Platform

Controller Hub (PCH) chipset)

The 4 th

Generation Intel

®

Core

i3 processors

Note: The previous generation Intel

®

Xeon

®

processors are not supported on the Intel

®

server board described in this document.

3.1.1 Intel

®

processor E3-1200 V3 product family

Intel

®

Xeon

®

processor E3-1200 v3 product family highly integrated solution variant is composed of quad processor cores:

LGA 1150 socket package with 5 GT/s

Up to 95 W Thermal Design Power (TDP)

The list of supported processors may be found at http://serverconfigurator.intel.com/sct_app.aspx

.

Revision 2.0 13

Functional Architecture

3.1.2 Intel

®

processor E3-1200 V4 product family

Intel

®

Xeon

®

processor E3-1200 v4 product family highly integrated solution variant is composed of quad processor cores:

LGA 1150 socket package with 5 GT/s

Up to 95 W Thermal Design Power (TDP)

The list of supported processors may be found at http://serverconfigurator.intel.com/sct_app.aspx

.

Note: The workstation processor is not supported in this platform.

3.1.3 The 4

th

Generation Intel

® ™

i3 Processors

The 4 th

Generation Intel

®

Core

i3 Processors highly integrated solution variant is composed of

Duo cores:

FC-LGA 1150 socket package with 5 GT/s

Up to 65 W Thermal Design Power (TDP); processors with higher TDP are not supported

The list of supported processors may be found at http://serverconfigurator.intel.com/sct_app.aspx

.

3.2 Processor Function Overview

With the release of the Intel

®

Xeon

®

processor E3-1200 V3/V4 product family, several key system components, including the CPU, Integrated Memory Controller (IMC), and Integrated IO

Module (IIO), have been combined into a single processor package and feature; up to 16 lanes of Gen 3 PCI Express* links. The FMA instruction has improved from 128 bit integer instruction to 256 bit integer, providing much better media processing performance.

The following sections provide an overview of the key processor features and functions that help to define the performance and architecture of the server board. For more comprehensive processor specific information, refer to the Intel

®

Xeon

®

processor E3-1200 V3/V4 product

family documents listed in the Reference Documents list.

Processor feature details:

Up to four execution cores

Each core supports two threads (Intel

®

Hyper-Threading Technology), up to 8 threads per socket

Supported technologies:

Intel

®

Virtualization Technology (Intel

®

VT-x)

Server Platform Services 3.0 (SPS3.0)

Intel

®

Trusted Execution Technology (Intel

®

TXT)

Intel

®

64 Architecture

14 Revision 2.0

Functional Architecture

Intel

Intel

Advanced Encryption Standard New Instructions (AES-NI)

Intel

Execute Disable Bit

Intel

PCLMULQDQ Instruction

Intel

®

®

®

®

®

PAIR

Streaming SIMD Extensions 4.2 (Intel

Advanced Vector Extensions 2.0 (Intel

Hyper-Threading Technology

Turbo Boost Technology

®

®

SSE4.2)

AVX2)

Transactional Synchronization Extensions (Intel

– Power Aware Interrupt Routing

SMEP

– Supervisor Mode Execution Protection

®

TSX)

Note: The SR-IOV function is not supported because the hardwar e doesn’t support ACS which is required to support SR-IOV.

3.3 Integrated Memory Controller (IMC) and Memory Subsystem

Integrated into the processor is a memory controller. Only ECC memory is supported on this platform. Each processor provides two DDR3L Unbuffered Dual In-Line Memory Modules

(UDIMM) channels that support the following:

ECC Unbuffered DDR3L

Single-channel and dual-channel memory organization modes

Data burst length of eight cycles for all memory organization modes

Memory DDR3 data transfer rates of 1333, and 1600 MT/s

64-bit wide channels

DDR3L I/O Voltage of 1.35 V

Theoretical maximum memory bandwidth of:

- 21.3 GB/s in dual-channel mode assuming 1333 MT/s

-

25.6 GB/s in dual-channel mode assuming 1600 MT/s

1 Gb, 2 Gb, and 4 Gb DDR3L DRAM device technologies are supported

- Using 4 Gb DRAM device technologies, the largest system memory capacity possible is 32 GB, assuming Dual Channel Mode with four x8 dual ranked DIMM memory configuration

Up to 64 simultaneous open pages, 32 per channel (assuming 8 ranks of 8 bank devices)

Processor on-die Vref generation for DDR DQ Read and Write as well as CMD/ADD

Command launch modes of 1n/2n

On-Die Termination (ODT)

Asynchronous ODT

Intel

®

Fast Memory Access (Intel

®

FMA):

-

Just-in-Time Command Scheduling

- Command Overlap

-

Out-of-Order Scheduling

The memory channels are named as Channel A and Channel B.

Revision 2.0 15

Functional Architecture

The memory slots are named as Slot1 and Slot2 on each channel. Slot1 is the farthest from the processor socket.

DIMMs are named to reflect the channel and slot in which they are installed:

3.3.1

-

Channel A, Slot1 is DIMM_A1.

- Channel A, Slot2 is DIMM_A2.

-

Channel B, Slot1 is DIMM_B1.

- Channel B, Slot2 is DIMM_B2.

Supported Memory

Single Ranked x8 unbuffered ECC

Dual Ranked x8 unbuffered ECC

Table 2. UDIMM Support Guidelines

Ranks

Per

DIMM and

Data

Width

Memory Capacity Per DIMM

Speed (MT/s) and Voltage Validated by

Slot per Channel (SPC) and DIMM Per Channel (DPC)

1 Slot per Channel 2 Slots per Channel

1DPC

1.35V

1DPC

1.35V

2DPC

1.35V

1333, 1600 1333, 1600 1333, 1600

SRx8

ECC

DRx8

ECC

1GB

2GB

2GB

4GB

Notes:

1. No support for RDIMMs.

4GB

8GB 1333, 1600 1333, 1600 1333, 1600

2. No support for SODIMM.

3. All channels in a system run at the fastest common frequency.

4. Mixing ECC and non-ECC UDIMMs anywhere on the platform is not supported.

5. Static CLTT supported using BMC (requires ECC DIMMs with thermal sensor).

3.3.1.1 Memory Population Rules

Note: Although mixed DIMM configurations are supported, Intel

®

only performs platform validation on systems that are configured with identical DIMMs installed.

The processor provides two channels of memory, each capable of supporting up to two DIMMs.

DIMMs are organized into physical slots on DDR3L memory channels that belong to processor sockets.

The silk screened DIMM slot identifiers on the board provide information about the channel. For example, DIMM_A1 is the first slot on Channel A on processor.

Slot1 must be populated first before Slot2, on either channel.

Channel A and Channel B are independent and are not required to have the same number of DIMMs installed. Either channel may be used for a single-DIMM configuration.

16 Revision 2.0

Functional Architecture

-

When only one memory channel is populated, the memory runs in Single Channel mode, with no interleaving.

On the Intel

®

Server Board S1200V3RP, a total of 4 DIMM slots is provided. The nomenclature for DIMM sockets is detailed in the following table.

Table 3. Intel

®

A1

(0)

Channel A

A2 B1

(1)

Channel B

B2

Max Memory Possible

Single Rank UDIMM

Dual Rank UDIMMs

Figure 10. Intel

®

Table 4. Intel

®

1Gb DRAM Technology

4GB

(4 x 1GB DIMMs)

8GB

(4 x 2GB DIMMs)

2Gb DRAM Technology

8GB

(4 x 2GB DIMMs)

16GB

(4x 4GB DIMMs)

4Gb DRAM Technology

16GB

(4 x 4GB DIMMs)

32GB

(4 x 8GB DIMMs)

Revision 2.0 17

Functional Architecture

3.3.1.2

Publishing System Memory

The BIOS displays the Total Memory of the system during POST if Display Logo is disabled in the BIOS setup. This is the total size of memory discovered by the BIOS during POST, and is the sum of the individual sizes of installed DDR3 DIMMs in the system.

The BIOS displays the Effective Memory of the system in the BIOS setup. The term

Effective Memory refers to the total size of all DDR3 DIMMs that are active (not disabled).

The BIOS provides the total memory of the system in the main page of the BIOS setup.

This total is the same as the amount described by the first bullet above.

If Display Logo is disabled, the BIOS displays the total system memory on the diagnostic screen at the end of POST. This total is the same as the amount described by the first bullet above.

Note: Some server operating systems do not display the total physical memory installed. What is displayed is the amount of physical memory minus the approximate memory space used by system BIOS components. These BIOS components include, but are not limited to:

1. ACPI (may vary depending on the number of PCI devices detected in the system)

2. ACPI NVS table

3. Processor microcode

4. Memory Mapped I/O (MMIO)

5. Manageability Engine (ME)

6. BIOS flash

3.3.2 Memory RAS Features

For Intel

®

Server Board S1200V3RP product family, the form of Memory RAS provided is Error

Correction Code (ECC). ECC uses extra bits

– 64-bit data in a 72-bit DRAM array – to add an 8bit calculated Hamming Code to each 64 bits of data. This additional encoding enables the memory controller to detect and report single or double bit errors, and to correct single-bit errors.

There is a specific step in memory initialization in which all of memory is cleared to zeroes before the ECC function is enabled, in order to bring the ECC codes into agreement with memory contents.

During operation, in the process of every fetch from memory, the data and ECC bits are examined for each 64-bit data plus 8-bit ECC group. If the ECC computation indicates that a single bit Correctable Error has occurred, it is corrected and the corrected data is passed on to the processor. If a double-bit Uncorrectable Error is detected, it cannot be corrected. In each case, a Correctable or Uncorrectable ECC Error event is generated.

For Correctable Errors, there is a certain tolerance observed, since a Correctable Error can be generated by something as random as a stray Cosmic Ray impacting the DIMM. Correctable

Errors are counted on a per-DIMM basis, but are just silently recorded until the tolerance threshold is crossed. The Correctable Error Threshold for Intel

®

Server Board S1200V3RP

18 Revision 2.0

Functional Architecture product family board is set at 10 events. When the 10 th

CE occurs, a single Correctable Error event is logged.

3.3.3 Post Error Codes

The range {0xE0 - 0xEF} of POST codes is used for memory errors in early POST. In late POST, this same range of POST code values is used for reporting other system errors.

0xE8 - No Usable Memory Error: If no usable memory is available, the BIOS emits a beep code and displays POST Diagnostic LED code 0xE8 and halts the system.

This can also occur if all memory in the system fails and/or has become disabled during memory initialization. For example, if a DDR3 DIMM has no SPD information, the BIOS treats the DIMM slot as if no DDR3 DIMM is present on it. Therefore, if this is the only

DDR3 DIMM installed in the system, there is no usable memory, and the BIOS goes to a memory error code 0xE8 as described above.

0x53/0x55/0XE8: DIMM SPD does not respond or DIMM SPD Read Error, the DIMM will not be detected, if the SPD does not respond, which could result in No memory Installed or No Usable Memory Error Halt 0X53, 0x55, or 0xE8, or could result later in an invalid configuration if the no SPD DIMM is in Slot 1 on the channel.

0x51

– Memory SPD Error: If the DIMM does respond but the SPD cannot be successfully read, that would cause a Memory SPD Error, memory error halt 0X51. For each memory channel, once the DIMM SPD parameters have been read, they are checked to verify that the DIMMs on the channel are a valid configuration, DIMM speed and size, ECC capability, and in which memory slot the DIMMs are installed. An invalid configuration will cause the system to halt.

0xEA - Channel Training Error: If the memory initialization process is unable to properly perform the Data/Data Strobe timing training on a memory channel, the BIOS emits a beep code and displays POST Diagnostic LED code 0xEA momentarily during the beeping. If there is usable memory in the system on other channels, POST memory initialization continues. Otherwise, the system beeps and halts with POST Diagnostic

LED code 0xEA staying displayed.

0x54/0xEB - Memory Test Error: If a DDR3 DIMM or a set of DDR3 DIMMs on the same memory channel fails memory testing but usable memory remains available, the

BIOS emits a beep code and displays POST Diagnostic LED code 0xEB momentarily during the beeping, then continues POST. If all of the memory fails memory testing, then system memory error code 0xE8 (No Usable Memory) as described above.

0xED - Population Error or Invalid DIMM: If the installed memory contains an invalid

DIMM configuration on any channel in the system, the system beeps and halts with

POST Diagnostic LED code 0xED. The DIMM are installed incorrectly, not following the

Fill Farthest First rule (Slot 1 must be filled before Slot 2). This will result in a DIMM

Population Error, with a Memory Error Halt 0xED.

3.3.4 Processor Integrated I/O Module (IIO)

The processor’s integrated I/O module provides features traditionally supported through chipset components. The integrated I/O module provides the following features:

PCI Express* Interfaces

The integrated I/O module incorporates the PCI Express* interface and supports up to

16 lanes of PCI Express*. Following are key attributes of the PCI Express* interface:

Revision 2.0 19

Functional Architecture

-

Gen3 speeds at 8 GT/s (no 8b/10b encoding)

- Can operate at 2.5 GT/s, 5 GT/s, or 8 GT/s

The Intel

®

Server Board S1200V3RPL and S1200V3RPS support PCIe slots:

-

Slot 7: PCI Express* Gen2 x1 electrical with x8 physical connector, from PCH.

- Slot 6: PCI Express* Gen2 x 16 or Gen3 x8 electrical with x16 physical connector, from processor.

-

Slot 5: PCI Express* Gen2 x8 or x4 electrical with x8 physical connector, from processor.

- Slot 4: PCI Express* Gen2 x4 electrical with x8 physical connector, from PCH.

The Intel

®

Server Board S1200V3RPO and S1200V3RPM support PCIe slots:

-

Slot 6: PCI Express* Gen3 x16 electrical with x16 physical connector, from processor.

Table 5. PCI Express* Speed Matrix for Each Configuration

Board Name

S1200V3RPS

S1200V3RPL

Slot4

PCI

Express*

Gen2 x4

Slot4

PCI

Express*

Gen2 x4

Slot7

PCI

Express*

Gen2 x1

Slot7

PCI Express* Slot

Slot5

PCI Express* Gen2

Slot5 x8

Slot6

PCI

Express*

Gen2 x1

No card installed

PCI

Express*

Gen2 x8

PCI

Express*

Gen2 x4

IO Module

PCI

Express*

Gen3 x8 or Gen2 x16

PCI

Express*

Gen3 x8

PCI

Express*

Gen3 x8

Gen3 x8

Slot6

PCI

Express*

Gen3 x8

SAS Module

No Card installed

PCI

Express*

Gen2 x8

No Card installed

PCI

Express*

Gen2 x4

SAS module

S1200V3RPO

S1200V3RPM

Slot6

PCI

Express*

Gen2 x16 or

Gen3 x8

PCI

Express*

Gen3 x8 or don’t have add-in card

Don’t have add-in module

PCI Express* Gen2 x8

Don’t have add-in module

Don’t have add-in module

PCI Express* Gen2 x8

PCI Express* Gen2 x4

Don’t have add-in module

PCI Express* Gen2 x4

Note: If no device is installed on IO Module connector or Slot5, the device connecting to Intel

®

SAS module connector can work as PCI Express* Gen2 x4 electrical; if any device is installed on IO Module connector or Slot5, the Intel

®

SAS modules (RMS25JB080 and RMS25JB040) can work as PCI Express* Gen2 x4 electrical and the Intel

®

ROC modules (RMS25CB080 and

RMS25CB040) cannot be detected.

20 Revision 2.0

Functional Architecture

Direct Media Interface (DMI)

Direct Media Interface (DMI) connects the processor and the PCH. DMI2.0 is supported.

Note: Only DMI x4 configuration is supported.

- DMI 2.0 support.

-

Compliant to Direct Media Interface Second Generation (DMI2).

- Four lanes in each direction.

-

5 GT/s point-to-point DMI interface to PCH is supported.

3.3.5 Intel

®

The Intel

®

Server Board S1200V3RPL, S1200V3RPO, and S1200V3RPM provide a SAS/ROC

Mezzanine slot (J4J1) to a high density 80-pin connector labeled SAS_MOD for the installation of an optional Intel

®

Integrated RAID Module. For more information, please refer to Table 5.

Features of this option include:

SKU options to support full or entry level hardware RAID

Dual-core 6Gb SAS ROC/IOC (LSI* 2208)

4 or 8 port and SAS/SATA or SATA

– only ROC options

SKU options to support 512MB or 1GB embedded memory

Intel

®

designed flash plus optional support for Intel

®

RAID Maintenance Free Backup

Units (AXXRMFBU2) or improved Lithium Polymer battery

Table 6. Supported Intel

®

External Name

Intel

®

Integrated RAID Module

RMS25CB080

Description

8 Port SAS-2.1, Full HW RAID, 1GB, IOM

Slot

RAID Levels 0,1,10, 5, 50, 6, 60

Product Code

RMS25CB080

Intel

®

Integrated RAID Module

RMS25CB040

Intel

®

Integrated RAID Module

RMT3CB080

4 Port SAS-2.1, Full HW RAID, 1GB, IOM

Slot

RAID Levels 0,1,10, 5, 50, 6, 60

8 Port SATA-3, Full HW RAID, 512MB,

IOM Slot

RAID Levels 0,1,10, 5, 50, 6, 60

RMS25CB040

RMT3CB080

Intel

®

Integrated RAID Module

RMS25KB080

8 Port SAS-2.1, Entry-level HW RAID,

IOM Slot

RAID Levels 0,1,1E

RMS25KB080

Intel

®

Integrated RAID Module

RMS25KB040

4 Port SAS-2.1, Entry-level HW RAID,

IOM Slot

RMS25KB040

RAID Levels 0,1,1E

For additional product information, refer to the document Intel

®

Integrated RAID Module

RMS25KB080, RMS25KB040, RMS25CB080, and RMS25CB040 Hardware User’s Guide.

3.3.6 Optional I/O Module Support

To broaden the standard on-board feature set, the Intel

®

Server Board S1200V3RPO and

S1200V3RPM provide support for one of several available IO Module options. The I/O module

Revision 2.0 21

Functional Architecture attaches to a high density 80-pin connector on the server board (J1C1) labeled I/O_MOD and is supported by up to x8 PCIe Gen3 signals from the IIO module of the processor.

3.3.7 Intel

®

Intel

®

I/O AT2 is not supported.

I/O AT2)

3.3.7.1 Direct Cache Access (DCA)

Direct Cache Access (DCA) is not supported on Intel

®

Xeon

®

Processor E3-1200 V3/V4 series.

3.4 Intel

®

The following subsections provide an overview of the key features and functions of the Intel

®

C220 series chipset PCH used on the server board. For more comprehensive chipset specific information, refer to the Intel

®

C220 series chipset documents listed in the Reference Document

list.

Slot 4

(x8 connector)

Slot 7

(x4 or x8 connector)

SATA-III

SATA-II

P1, P2, P3, P4

PCIe Gen2 x4

PCIe Gen2 x1

P8

SPI

Intel

®

PCH

C220 Series

SATA 6G

4 2

10

4

SATA 3G

USB 2.0

USB 3.0

2

2

1 1

P7

( PCIe Gen1 x1 )

P6 ( PCIe Gen1 x1 )

P5

Intel® I210

Gigabit

Ethernet

Controller

RMII

Intel® I210

Gigabit

Ethernet

Controller

BMC Boot

Flash

LPC

TPM

2

2

SPI

2

BMC

Zoar

III

USB

1.1

USB

2.0

SGPIO

PORT 80

LED

RGMII

DNM

GbE

GbE

Back

Panel

Back

Panel

VIDEO

Back

Panel

Misc

VR s

On Standby

SERIAL 2

Front

Panel

Header

SERIAL 1

Back

Panel

Difference on SE SKU

·

SATA: 2x6G + 4x3G

·

·

USB: USB2 for front panel

No DNM

Front Panell

USB 3.0

Header

Type-A

Header

USB USB eUSB

Header

Back

Panel

USB 3.0

Back

Panel

USB 2.0

Figure 11. Functional Block Diagram – Chipset Supported Features and Functions

On the Intel

®

Server Boards S1200V3RP, the chipset provides support for the following onboard functions:

Digital Media Interface (DMI) to Processor

PCI Express* Interface

Serial ATA (SATA) Controller

AHCI

Rapid Storage Technology enterprise (RSTe)

Low Pin Count (LPC) interface

Serial Peripheral Interface (SPI)

Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)

Advanced Programmable Interrupt Controller (APIC)

Universal Serial Bus (USB) Controller

22 Revision 2.0

Functional Architecture

3.4.1

Gigabit Ethernet Controller

RTC

GPIO

Enhanced Power Management

Manageability

System Management Bus (SMBus* 2.0)

Integrated NVSRAM controller

Virtualization Technology for Direct I/O (Intel

®

VT-d)

JTAG Boundary-Scan

KVM/Serial Over LAN (SOL) Function

Digital Media Interface (DMI)

Digital Media Interface (DMI) is the chip-to-chip connection between the processor and the

Intel

®

C220 series chipset. This high-speed interface integrates advanced priority-based servicing allowing for concurrent traffic and true isochronous transfer capabilities. Base functionality is completely software-transparent, permitting current and legacy software to operate normally.

3.4.2 PCI Express* Interface

The Intel

®

C220 series chipset provides up to 8 PCI Express* Root Ports, supporting the PCI

Express* Base Specification, Revision 2.0. Each Root Port x1 lane supports up to 5 Gb/s bandwidth in each direction (10 Gb/s concurrent). On the Intel

®

Server Board S1200V3RPL and

S1200V3RPS, PCI Express* Root Ports 1-4 is configured to support one Gen2 x4 port widths of slot 4; PCI Express* Root Port 8 is configured to support one Gen2 x1 port widths of slot 7. On the Intel

®

Server Boards S1200V3RP family product, PCI Express* Root Port 5 is configured to support one Gen1 x1 widths connection with the BMC chip; PCI Express* Root Port 5 and 6 are configured to support two Gen1 x1 widths connection with the two Intel

®

I210 Gigabit Ethernet

Network controller.

3.4.3 Serial ATA (SATA) Controller

The Intel

®

C220 series chipset provides SATA host controllers that support independent DMA operation on up to six ports and supports data transfer rates of up to 6.0 Gb/s (600 MB/s) on up to six ports while all ports support rates up to 3.0 Gb/s. The SATA controller contains two modes of operation

– a legacy mode using I/O space, and an AHCI mode using memory space.

Software that uses legacy mode will not have AHCI capabilities. The Intel

®

C220 series chipset supports the Serial ATA Specification, Revision 3.0. The Intel

®

C220 series also supports several optional sections of the Serial ATA II: Extensions to Serial ATA 1.0 Specification,

Revision 1.0 (AHCI support is required for some elements).

SKU Name

S1200V3RPO

S1200V3RPS

S1200V3RPL

S1200V3RPM

Table 7. Intel

®

SATA Port 0, 1

Up to 6.0 Gb/s

Up to 6.0 Gb/s

Up to 6.0 Gb/s

SATA Port 2, 3

Up to 6.0 Gb/s

Up to 3.0 Gb/s

Up to 6.0 Gb/s

SATA Port 4, 5

Up to 3.0 Gb/s

Up to 3.0 Gb/s

Up to 6.0 Gb/s

Revision 2.0 23

Functional Architecture

3.4.3.1 AHCI

The Intel

®

C220 series chipset provides hardware support for Advanced Host Controller

Interface (AHCI), a standardized programming interface for SATA host controllers. Platforms supporting AHCI may take advantage of performance features such as no master/slave designation for SATA devices

—each device is treated as a master—and hardware assisted native command queuing. AHCI also provides usability enhancements such as Hot-Plug. AHCI requires appropriate software support (for example, an AHCI driver) and for some features, hardware support in the SATA device or additional platform hardware.

The server board includes support for two embedded software RAID options:

Intel

®

Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW

RAID technology

Intel

®

Rapid Storage Technology (RSTe)

Using the <F2> BIOS Setup Utility, accessed during system POST, options are available to enable/disable SW RAID, and select which embedded software RAID option to use.

3.4.3.2 Intel

®

The Intel

®

C220 series chipset provides support for Intel

®

Rapid Storage Technology enterprise, providing both AHCI (see above for details on AHCI) and integrated RAID functionality. The industry-leading RAID capability provides high-performance RAID 0, 1, 5, and 10 functionality on up to 6 SATA ports of the Intel

®

C220 series chipset. RSTe RAID support is provided to allow multiple RAID levels to be combined on a single set of hard drives, such as RAID 0 and RAID 1 on two disks. Other RAID features include hot-spare support, SMART alerting, and RAID 0 auto replace. Software components include an Option ROM for pre-boot configuration and boot functionality, a Microsoft Windows* compatible driver, and a user interface for configuration and management of the RAID capability of the Intel

®

C220 series chipset.

3.4.3.3 Intel

®

Features of the embedded software RAID option Intel

®

Embedded Server RAID Technology 2

(ESRT2) include the following:

Based on LSI* MegaRAID Software Stack

Software RAID with system providing memory and CPU utilization

Supported RAID Levels

– 0, 1, 10, RAID 5 support provides with upgrade key of

RKSATA4R5.

Open Source Compliance = Binary Driver (includes Partial Source files) or Open Source using MDRAID layer in Linux*

OS Support = Microsoft Windows 2012*, Microsoft Windows 2008*, RHEL*, SLES, and other Linux* variants using partial source builds

3.4.4

Utilities = Microsoft Windows* GUI and CLI, Linux* GUI and CLI, DOS CLI, and EFI CLI

Low Pin Count (LPC) Interface

The Intel

®

C220 series chipset implements an LPC Interface as described in the LPC 1.1

Specification and provides support for up to two Master/DMI devices. On the server board, the

LPC interface is utilized as an interconnection between the chipset and the Integrated Base

24 Revision 2.0

Functional Architecture

Board Management Controller as well as providing support for the optional Trusted Platform

Module (TPM).

3.4.5 Serial Peripheral Interface (SPI)

The Intel

®

C220 series chipset implements an SPI Interface as an alternative interface for the

BIOS flash device.

3.4.6 Universal Serial Bus (USB) Controller

The Intel

®

C220 series chipset has up to two Enhanced Host Controller Interface (EHCI) host controllers that support USB high-speed signaling. High-speed USB 2.0 allows data transfers up to 480 Mb/s which is 40 times faster than full-speed USB.

The Intel

®

C220 series chipset contains an eXtensible Host Controller Interface (xHCI) host controller which supports up to fourteen USB 2.0 ports of which up to six can be used as

USB3.0 ports with board routing, ACPI table, and BIOS considerations. This controller allows data transfers of up to 5Gb/s. The controller supports SuperSpeed (SS), high-speed (HS), fullspeed (FS), and low speed (LS) traffic on the bus.

Table 8. Intel

®

Board SKU

Rear USB Ports

USB 1, 2

(USB2.0)

USB 3, 4

(USB3.0)

J1J1 (USB 5, 6)

(USB3.0)

Internal USB Headers

J1J4 (USB 7)

(USB2.0 Type A)

J1K3 (USB 8,9)

(USB2.0)

J5K1 eUSB

(USB2.0)

S1200V3RPL

S1200V3RPO

S1200V3RPM

S1200V3RPS

Yes

Yes

Yes

Yes

Yes

No

Yes

Yes

Yes

Yes

Yes

Yes

3.4.6.1 Native USB Support

During the power-on self-test (POST), the BIOS initializes and configures the USB subsystem.

The BIOS can initialize and use the following types of USB devices:

USB Specification-compliant keyboards

USB Specification-compliant mouse

USB Specification-compliant storage devices that utilize bulk-only transport mechanism

USB devices are scanned to determine if they are required for booting.

The BIOS supports USB 2.0 mode of operation, and as such supports USB 1.1 and USB 2.0 compliant devices and host controllers.

During the pre-boot phase, the BIOS automatically supports the hot addition and hot removal of

USB devices and a short beep is emitted to indicate such an action. For example, if a USB device is hot plugged, the BIOS detects the device insertion, initializes the device, and makes it available to the user. During POST, when the USB controller is initialized, it emits a short beep for each USB device in the system as if they were all just “hot added”.

Only on-board USB controllers are initialized by BIOS. This does not prevent the operating system from supporting any available USB controllers including add-in cards.

Revision 2.0 25

Functional Architecture

3.4.6.2 Legacy USB Support

The BIOS supports PS/2 emulation of USB keyboards and mouse. During POST, the BIOS initializes and configures the root hub ports and searches for a keyboard and/or a mouse on the

USB hub and then enables the devices that are recognized.

3.4.6.3 eUSB SSD Support

The server board provides support for a low profile eUSB SSD storage device. A 2mm 2x5-pin connector labeled eUSB SSD near the rear I/O section of the server board is used to plug this small flash storage device into. eUSB SSD features include:

Two wire small form factor Universal Serial Bus 2.0 (Hi-Speed USB) interface to host

Read Speed up to 35 MB/s and write Speed up to 24 MB/s

Capacity range from 256 MB to 32 GB

3.4.7

Support USB Mass Storage Class requirements for Boot capability

Gigabit Ethernet Controller

Network connectivity is provided by means of two onboard Intel

®

Ethernet Controller I210 providing up to two 10/100/1000 Mb Ethernet ports. The Intel

®

Ethernet Controller I210 is single, compact, low-power components that offer a fully-integrated Gigabit Ethernet Media Access

Control (MAC) and Physical Layer (PHY) port. The Intel

®

Ethernet Controller I210 uses the PCI

Express* architecture from the Intel

®

C220 series PCH and provides a single-port implementation in a relatively small area so it can be used for server and client configurations as a LAN on Motherboard (LOM) design.

External interfaces provided on the I210:

PCIe Rev. 2.0 (2.5 GHz) x1

MDI (Copper) standard IEEE 802.3 Ethernet interface for 1000BASE-T, 100BASETX, and 10BASE-T applications (802.3, 802.3u, and 802.3ab)

NC-SI or SMBus* connection to a Manageability Controller (MC)

EEE 1149.1 JTAG (note that BSDL testing is NOT supported)

Each Ethernet port drives two LEDs located on each network interface connector. The LED at the right of the connector is the link/activity LED and indicates network connection when on, and transmit/receive activity when blinking. The LED at the left of the connector indicates link speed as defined in the following table.

Table 9. External RJ45 NIC Port LED Definition

26

LED Color

Green/Amber (Right) Off

LED State

10 Mbps

NIC State

Revision 2.0

Functional Architecture

LED Color

Green (Left)

Amber

Green

On

Blinking

LED State

100 Mbps

NIC State

1000 Mbps

Active Connection

Transmit/Receive activity

3.4.7.1 MAC Address Definition

Each Intel

®

Server Board S1200V3RPL, S1200RPO, or S1200RPM has the following MAC addresses assigned to it at the factory:

NIC 1 MAC address (for OS usage)

NIC 2 MAC address

– Assigned the NIC 1 MAC address +1 (for OS usage)

Integrated BMC LAN Channel MAC address

– Assigned the NIC 1 MAC address +2

Intel

®

Remote Management Module 4 dedicated NIC MAC address

– Assigned the NIC

1 MAC address +3

Each Intel

®

Server Board S1200V3RPS has the following MAC addresses assigned to it at the factory:

NIC 1 MAC address

NIC 2 MAC address

– Assigned the NIC 1 MAC address +1

Integrated BMC LAN Channel MAC address

– Assigned the NIC 1 MAC address +2

3.4.8 Enhanced Power Management

The Intel

®

C220 series chipset’s power management functions include enhanced clock control and various low-power (suspend) states (for example, Suspend-to-RAM and Suspend-to-Disk).

A hardware-based thermal management circuit permits software-independent entrance to lowpower states. The Intel

®

C220 series chipset contains full support for the Advanced

Configuration and Power Interface (ACPI) Specification, Revision 4.0a.

3.4.9 Serial Ports

The server board provides two serial ports: an external DB9 serial port connector and an internal DH-10 serial header.

The rear DB9 Serial A port is a fully functional serial port that can support any standard serial device.

The Serial B port is an optional port accessed through a nine-pin internal DH-10 header (J9A2).

You can use a standard DH-10 to DB9 cable to direct serial A port to the rear of a chassis.

3.4.10 KVM/Serial Over LAN (SOL) Function

These functions support redirection of keyboard, mouse, and text screen to a terminal window on a remote console. The keyboard, mouse, and text redirection enables the control of the client

Revision 2.0 27

Functional Architecture machine through the network without the need to be physically near that machine. Text, mouse, and keyboard redirection allows the remote machine to control and configure the client by entering BIOS setup. The KVM/SOL function emulates a standard PCI serial port and redirects the data from the serial port to the management console using LAN. KVM has additional requirements of internal graphics and SOL may be used when KVM is not supported.

3.4.11 System Management Bus (SMBus* 2.0)

The Intel

®

C220 series chipset contains a SMBus* Host interface that allows the processor to communicate with SMBus* slaves. This interface is compatible with most I2C devices. Special

I2C commands are implemented. The Intel

®

C

220 series chipset’s SMBus* host controller provides a mechanism for the processor to initiate communications with SMBus* peripherals

(slaves). Also, the Intel

®

C220 series chipset supports slave functionality, including the Host

Notify protocol. Hence, the host controller supports eight command protocols of the SMBus* interface (see System Management Bus (SMBus*) Specification, Version 2.0): Quick Command,

Send Byte, Receive Byte, Write Byte/Word, Read Byte/Word, Process Call, Block Read/Write, and Host Notify.

The Intel

®

C220 series chipset’s SMBus* also implements hardware-based Packet Error

Checking for data robustness and the Address Resolution Protocol (ARP) to dynamically provide address to all SMBus* devices.

3.4.12 Intel

®

VT-d)

The Intel

®

C220 series chipset provides hardware support for implementation of Intel

®

Virtualization Technology with Directed I/O (Intel

®

VT-d). Intel

®

VT-d Technology consists of technology components that support the virtualization of platforms based on Intel

®

Architecture

Processors. Intel

®

VT-d Technology enables multiple operating systems and applications to run in independent partitions. A partition behaves like a Virtual Machine (VM) and provides isolation and protection across partitions. Each partition is allocated its own subset of host physical memory.

3.5 Integrated Baseboard Management Controller (BMC) Overview

The server board utilizes the I/O controller, Graphics Controller, and Baseboard Management features of the Emulex* Pilot-III Management Controller. The following is an overview of the features as implemented on the server board from each embedded controller.

28 Revision 2.0

Figure 12. Integrated Baseboard Management Controller (BMC) Overview

Functional Architecture

Revision 2.0

Figure 13. Integrated BMC Functional Block Diagram

29

Functional Architecture

3.5.1 Super I/O Controller

The integrated super I/O controller provides support for the following features as implemented on the server board:

Two Fully Functional Serial Ports, compatible with the 16C550

Serial IRQ Support

Up to 16 Shared direct GPIO’s

Serial GPIO support for 80 general purpose inputs and 80 general purpose outputs available for host processor

3.5.1.1

Programmable Wake-up Event Support

Plug and Play Register Set

Power Supply Control

Host SPI bridge for system BIOS support

Keyboard and Mouse Support

The server board does not support PS/2 interface keyboards and mice. However, the system

BIOS recognizes USB specification-compliant keyboard and mice.

3.5.1.2 Wake-up Control

The super I/O contains functionality that allows various events to power on and power off the system.

3.5.2 Graphics Controller and Video Support

The integrated graphics controller provides support for the following features as implemented on the server board:

Integrated Graphics Core with 2D Hardware accelerator

DDR-3 memory interface supporting up to 128MB of memory, 16MB allocated to graphic

Supports display resolutions up to 1600 x 1200 16bpp @ 60Hz

High speed Integrated 24-bit RAMDAC

Single lane PCI Express* host interface running at Gen 1 speed

The integrated video controller supports all standard IBM VGA modes. The following table shows the 2D modes supported for both CRT and LCD:

Table 10. Video Modes

2D Mode 2D Video Mode Support

8 bpp 16 bpp 24 bpp 32 bpp

X X X X

640x480

800x600

X

1024x768

X

1152x864

X

1280x1024

X

X

X

X

X

X

X

X

X

X

X

X

X

1600x1200** X

X

** Video resolutions at 1600x1200 and higher are only supported through the external video connector located on the rear I/O section of the server board.

30 Revision 2.0

Functional Architecture

The BIOS supports dual-video mode when an add-in video card is installed.

In the single mode (dual monitor video = disabled), the on-board video controller is disabled when an add-in video card is detected.

In the dual mode (on-board video = enabled, dual monitor video = enabled), the onboard video controller is enabled and is the primary video device. The add-in video card is allocated resources and is considered the secondary video device. The BIOS Setup utility provides options to configure the feature as follows:

Table 11. Video Mode

On-board Video

Dual Monitor Video

Enabled

Disabled

Enabled

Disabled

Shaded if on-board video is set to "Disabled"

On Intel

®

Server Board S1200V3RPM, the display port is from the processor. The processor graphics contains a generation 7.5 graphics core architecture. This enables substantial gains in performance and lower power consumption over previous generations. Up to 20 EUs are supported depending on the processor SKU.

Next Generation Intel

®

Clear Video Technology HD Support is a collection of video playback and enhancement features that improve the end user’s viewing experience

- Encode/transcode HD content

-

Playback of high definition content including Blu-ray Disc*

- Superior image quality with sharper, more colorful images

-

Playback of Blu-ray* disc S3D content using HDMI (1.4a specification compliant with

3D)

DirectX* Video Acceleration (DXVA) support for accelerating video processing

- Full AVC/VC1/MPEG2 HW Decode

Advanced Scheduler 2.0, 1.0, XPDM support

With display port, the maximum display resolution is 3840x2160@60Hz, 24bpp.

The supporting Operation System for display port Video output is Microsoft Windows 7*; other

OS is not supported.

To use pGFX and BMC graphic as mixed (also known as: heterogeneous) graphic solution:

Both BMC and Internal graphic need to be enabled/active in BIOS setup

Select Internal graphic as primary display

Note: Internal graphic will not support local display unless it is set as primary display.

Load add-in graphic driver for BMC and pGFX

For more information of pGFX on RBP RM SKU, refer to 3-Display Architecture and

Configuration Overview (Supporting: 3rd Generation Intel

Generation Intel

®

Core

Processors).

®

Core

Processors and4th

Revision 2.0 31

Functional Architecture

3.5.3 Baseboard Management Controller

The server board utilizes the following features of the embedded baseboard management controller:

IPMI 2.0 Compliant

400MHz 32-bit ARM9 processor with memory management unit (MMU)

Two independent10/100/1000 Ethernet Controllers with RMII/RGMII support

DDR2/3 16-bit interface with up to 800 MHz operation

12 10-bit ADCs

Fourteen fan tachometers

Eight Pulse Width Modulators (PWM)

Chassis intrusion logic

JTAG Master

Eight I2C interfaces with master-slave and SMBus* timeout support. All interfaces are

SMBus* 2.0 compliant.

Parallel general-purpose I/O Ports (16 direct, 32 shared)

Serial general-purpose I/O Ports (80 in and 80 out)

Three UARTs

Platform Environmental Control Interface (PECI)

Six general-purpose timers

Interrupt controller

Multiple SPI flash interfaces

NAND/Memory interface

Sixteen mailbox registers for communication between the BMC and host

LPC ROM interface

BMC watchdog timer capability

SD/MMC card controller with DMA support

LED support with programmable blink rate controls on GPIOs

Port 80h snooping capability

Secondary Service Processor (SSP), which provides the HW capability of offloading time critical processing tasks from the main ARM core.

3.5.3.1

Remote Keyboard, Video, Mouse, and Storage (KVMS) Support

USB 2.0 interface for Keyboard, Mouse, and Remote storage such as CD/DVD ROM and USB Flash Drive

USB 1.1/USB 2.0 interface for PS2 to USB bridging, remote Keyboard and Mouse

Hardware Based Video Compression and Redirection Logic

Supports both text and Graphics redirection

Hardware assisted Video redirection using the Frame Processing Engine

Direct interface to the Integrated Graphics Controller registers and Frame buffer

Hardware-based encryption engine

32 Revision 2.0

Functional Architecture

3.5.3.2 Integrated BMC Embedded LAN Channel

The Integrated BMC hardware includes two dedicated 10/100 network interfaces. These interfaces are not shared with the host system. At any time, only one dedicated interface may be enabled for management traffic. The default active interface is the NIC 1 port.

For these channels, support can be enabled for IPMI-over-LAN and DHCP. For security reasons, embedded LAN channels have the following default settings:

IP Address: Static

All users disabled

Revision 2.0 33

System Security

4. System Security

4.1 BIOS Password Protection

The BIOS uses passwords to prevent unauthorized tampering with the server setup. Passwords can restrict entry to the BIOS Setup, restrict use of the Boot Popup menu, and suppress automatic USB device reordering.

There is also an option to require a Power On password entry in order to boot the system. If the

Power On Password function is enabled in Setup, the BIOS will halt early in POST to request a password before continuing POST.

Both Administrator and User passwords are supported by the BIOS. An Administrator password must be installed in order to set the User password. The maximum length of a password is 14 characters. A password can have alphanumeric (a-z, A-Z, 0-9) characters and it is case sensitive. Certain special characters are also allowed, from the following set:

! @ # $ % ^ & * ( ) - _ + = ?

The Administrator and User passwords must be different from each other. An error message will be displayed if there is an attempt to enter the same password for one as for the other.

The use of Strong Passwords is encouraged, but not required. In order to meet the criteria for a

Strong Password, the password entered must be at least 8 characters in length, and must include at least one each of alphabetic, numeric, and special characters. If a weak password is entered, a popup warning message will be displayed, although the weak password will be accepted.

Once set, a password can be cleared by changing it to a null string. This requires the

Administrator password, and must be done through BIOS Setup or other explicit means of changing the passwords. Clearing the Administrator password will also clear the User password.

Alternatively, the passwords can be cleared by using the Password Clear jumper if necessary.

Resetting the BIOS configuration settings to default values (by any method) has no effect on the

Administrator and User passwords.

Entering the User password allows the user to modify only the System Time and System Date in the Setup Main screen. Other setup fields can be modified only if the Administrator password has been entered. If any password is set, a password is required to enter the BIOS setup.

The Administrator has control over all fields in the BIOS setup, including the ability to clear the

User password and the Administrator password.

It is strongly recommended that at least an Administrator Password be set, since not having set a password gives everyone who boots the system the equivalent of administrative access.

Unless an Administrator password is installed, any User can go into Setup and change BIOS settings at will.

In addition to restricting access to most Setup fields to viewing only when a User password is entered, defining a User password imposes restrictions on booting the system. In order to simply boot in the defined boot order, no password is required. However, the F6 Boot popup

34 Revision 2.0

System Security prompts for a password, and can only be used with the Administrator password. Also, when a

User password is defined, it suppresses the USB Reordering that occurs, if enabled, when a new USB boot device is attached to the system. A User is restricted from booting in anything other than the Boot Order defined in the Setup by an Administrator.

As a security measure, if a User or Administrator enters an incorrect password three times in a row during the boot sequence, the system is placed into a halt state. A system reset is required to exit out of the halt state. This feature makes it more difficult to guess or break a password.

In addition, on the next successful reboot, the Error Manager displays a Major Error code 0048, which also logs a SEL event to alert the authorized user or administrator that a password access failure has occurred.

4.2 Trusted Platform Module (TPM) Support

Trusted Platform Module (TPM) option is a hardware-based security device that addresses the growing concern on boot process integrity and offers better data protection. TPM protects the system start-up process by ensuring it is tamper-free before releasing system control to the operating system. A TPM device provides secured storage to store data, such as security keys and passwords. In addition, a TPM device has encryption and hash functions. The server board implements TPM as per TPM PC Client Specifications, revision 1.2, by the Trusted Computing

Group (TCG).

A TPM device is optionally installed onto a high density 14-pin connector labeled TPM and is secured from external software attacks and physical theft. A pre-boot environment, such as the

BIOS and operating system loader, uses the TPM to collect and store unique measurements from multiple factors within the boot process to create a system fingerprint. This unique fingerprint remains the same unless the pre-boot environment is tampered with. Therefore, it is used to compare to future measurements to verify the integrity of the boot process.

After the system BIOS completes the measurement of its boot process, it hands off control to the operating system loader and in turn to the operating system. If the operating system is TPMenabled, it compares the BIOS TPM measurements to those of previous boots to make sure the system was not tampered with before continuing the operating system boot process. Once the operating system is in operation, it optionally uses TPM to provide additional system and data security (for example, Microsoft Vista* supports Bitlocker drive encryption).

4.2.1 TPM security BIOS

The BIOS TPM support conforms to the TPM PC Client Specific

– Implementation Specification for Conventional BIOS, version 1.2, and to the TPM Interface Specification, version 1.2. The

BIOS adheres to the Microsoft Windows BitLocker* requirement. The role of the BIOS for TPM security includes the following:

Measures and stores the boot process in the TPM microcontroller to allow a TPM enabled operating system to verify system boot integrity.

Produces EFI and legacy interfaces to a TPM-enabled operating system for using TPM.

Produces ACPI TPM device and methods to allow a TPM-enabled operating system to send TPM administrative command requests to the BIOS.

Verifies operator physical presence. Confirms and executes operating system TPM administrative command requests.

Revision 2.0 35

System Security

Provides BIOS Setup options to change TPM security states and to clear TPM ownership.

For additional details, refer to the TCG PC Client Specific Implementation Specification, the

TCG PC Client Specific Physical Presence Interface Specification, and the Microsoft BitLocker*

Requirement documents.

4.2.2 Physical Presence

Administrative operations to the TPM require TPM ownership or physical presence indication by the operator to confirm the execution of administrative operations. The BIOS implements the operator presence indication by verifying the setup Administrator password.

A TPM administrative sequence invoked from the operating system proceeds as follows:

1.

User makes a TPM administrative request through the operating system’s security software.

2. The operating system requests the BIOS to execute the TPM administrative command through TPM ACPI methods and then resets the system.

3. The BIOS verifies the physical presence and confirms the command with the operator.

4. The BIOS executes TPM administrative commands, inhibits BIOS Setup entry, and boots directly to the operating system which requested the TPM commands.

4.2.3 TPM Security Setup Options

The BIOS TPM Setup allows the operator to view the current TPM state and to carry out rudimentary TPM administrative operations. Performing TPM administrative options through the

BIOS setup requires TPM physical presence verification.

Using BIOS TPM Setup, the operator can turn ON or OFF TPM functionality and clear the TPM ownership contents. After the requested TPM BIOS Setup operation is carried out, the option reverts to No Operation.

The BIOS TPM Setup also displays the current state of the TPM, whether TPM is enabled or disabled and activated or deactivated. Note that while using TPM, a TPM-enabled operating system or application may change the TPM state independent of the BIOS setup. When an operating system modifies the TPM state, the BIOS Setup displays the updated TPM state.

The BIOS Setup TPM Clear option allows the operator to clear the TPM ownership key and allows the operator to take control of the system with TPM. You use this option to clear security settings for a newly initialized system or to clear a system for which the TPM ownership security key was lost.

4.2.3.1 Security Screen

To enter the BIOS Setup, press the F2 function key during boot time when the OEM or Intel

® logo displays. The following message displays on the diagnostics screen and under the Quiet

Boot logo screen:

Press <F2> to enter setup

36 Revision 2.0

System Security

When the Setup is entered, the Main screen displays. The BIOS Setup utility provides the

Security screen to enable and set the user and administrative passwords and to lock out the front panel buttons so they cannot be used. The Intel

®

Server Board S1200V3RP provides TPM settings through the security screen.

To access this screen from the Main screen, select the Security option.

Setup Item

TPM State*

Figure 14. Setup Utility – TPM Configuration Screen

Table 12. TPM Setup Utility – Security Configuration Screen Fields

Options

Enabled and

Activated

Enabled and

Deactivated

Disabled and

Activated

Disabled and

Deactivated

Help Text Comments

Information only.

Shows the current TPM device state.

A disabled TPM device will not execute commands that use TPM functions and TPM security operations will not be available.

An enabled and deactivated TPM

Revision 2.0 37

System Security

Setup Item Options Help Text Comments is in the same state as a disabled

TPM except setting of TPM ownership is allowed if not present already.

An enabled and activated TPM executes all commands that use

TPM functions and TPM security operations will be available.

TPM

Administrative

Control**

No Operation

Turn On

Turn Off

Clear Ownership

[No Operation] - No changes to current state.

[Turn On] - Enables and activates

TPM.

[Turn Off] - Disables and deactivates TPM.

[Clear Ownership] - Removes the

TPM ownership authentication and returns the TPM to a factory default state.

Note: The BIOS setting returns to

[No Operation] on every boot cycle by default.

4.3 Intel

®

The Intel

®

Xeon

®

Processor E3-1200 V3/V4 Product Family support Intel

®

Trusted Execution

Technology (Intel

®

TXT), which is a robust security environment. Designed to help protect against software-based attacks, Intel

®

Trusted Execution Technology integrates new security features and capabilities into the processor, chipset, and other platform components. When used in conjunction with Intel

®

Virtualization Technology, Intel

®

Trusted Execution Technology provides hardware-rooted trust for your virtual applications.

This hardware-rooted security provides a general-purpose, safer computing environment capable of running a wide variety of operating systems and applications to increase the confidentiality and integrity of sensitive information without compromising the usability of the platform.

Intel

®

Trusted Execution Technology requires a computer system with Intel

®

Virtualization

Technology enabled (both VT-x and VT-d), an Intel

®

Trusted Execution Technology-enabled processor, chipset, and BIOS, Authenticated Code Modules, and an Intel

®

Trusted Execution

Technology compatible measured launched environment (MLE). The MLE could consist of a virtual machine monitor, an OS, or an application. In addition, Intel

®

Trusted Execution

Technology requires the system to include a TPM v1.2, as defined by the Trusted Computing

Group TPM PC Client Specification, Revision 1.2.

When available, Intel

®

Trusted Execution Technology can be enabled or disabled in the processor using a BIOS Setup option.

For general information about Intel

®

TXT, visit the Intel

®

Trusted Execution Technology website http://www.intel.com/technology/security/ .

38 Revision 2.0

5. Intel

®

5.1 Intel

®

The Intel

®

Xeon

®

Processor E3-1200 V3/V4 Product Families support Intel

®

Trusted Execution

Technology (Intel

®

TXT), which is a robust security environment designed to help protect against software-based attacks. Intel

®

Trusted Execution Technology integrates new security features and capabilities into the processor, chipset, and other platform components. When used in conjunction with Intel

®

Virtualization Technology and Intel

®

VT for Directed IO, with an active TPM, Intel

®

Trusted Execution Technology provides hardware-rooted trust for your virtual applications.

5.2 Intel

®

VT-x/VT-d/VT-c

Intel

®

Virtualization Technology consists of three components which are integrated and interrelated, but which address different areas of Virtualization.

Intel

®

Virtualization Technology (VT-x) is processor-related and provides capabilities needed to provide hardware assist to a Virtual Machine Monitor (VMM).

Intel

®

Virtualization Technology for Directed I/O (VT-d) is primarily concerned with virtualizing I/O efficiently in a VMM environment. This would generally be a chipset I/O feature, but in the Second Generation Intel

®

Core

Processor Family there is an

Integrated I/O unit embedded in the processor, and the IIO is also enabled for VT-d.

Intel

®

Virtualization Technology for Connectivity (VT-c) is primarily concerned I/O hardware assist features, complementary to but independent of VT-d.

Intel

®

VT-x is designed to support multiple software environments sharing same hardware resources. Each software environment may consist of OS and applications. The Intel

®

Virtualization Technology features can be enabled or disabled in the BIOS setup. The default behavior is disabled.

Intel

®

VT-d is supported jointly by the Intel

®

Xeon

®

Processor E3-1200 V3/V4 Product Families and The Intel

®

C220 series chipset. Both support DMA remapping from inbound PCI Express* memory Guest Physical Address (GPA) to Host Physical Address (HPA). PCI devices are directly assigned to a virtual machine leading to a robust and efficient virtualization.

The Intel

®

S1200V3RP Server Board Family BIOS publishes the DMAR table in the ACPI

Tables. For each DMA Remapping Engine in the platform, one exact entry of DRHD (DMA

Remapping Hardware Unit Definition) structure is added to the DMAR. The DRHD structure in turn contains a Device Scope structure that describes the PCI endpoints and/or sub-hierarchies handled by the particular DMA Remapping Engine.

Similarly, there are reserved memory regions typically allocated by the BIOS at boot time. The

BIOS marks these regions as either reserved or unavailable in the system address memory map reported to the OS. Some of these regions can be a target of DMA requests from one or more devices in the system, while the OS or executive is active. The BIOS reports each such memory region using exactly one RMRR (Reserved Memory Region Reporting) structure in the

DMAR. Each RMRR has a Device Scope listing the devices in the system that can cause a

DMA request to the region.

Revision 2.0 39

For more information on the DMAR table and the DRHD entry format, refer to the Intel

®

Virtualization Technology for Directed I/O Architecture Specification. For more general information about VT-x, VT-d, and VT-c, a good reference is Enabling Intel

®

Virtualization

Technology Features and Benefits White Paper.

5.3 Intel

®

Data centers are faced with power and cooling challenges that are driven by increasing numbers of servers deployed and server density in the face of several data center power and cooling constraints. In this type of environment, Information Technology (IT) needs the ability to monitor actual platform power consumption and control power allocation to servers and racks in order to solve specific data center problems including the following issues.

Table 13. Intel

®

IT Challenge

Over-allocation of power

Requirement

 Ability to monitor actual power consumption

 Control capability that can maintain a power budget to enable dynamic power allocation to each server

Under-population of rack space Control capability that can maintain a power budget to enable increased rack population

High energy costs

Capacity planning

Detection and correction of hot spots

Control capability that can maintain a power budget to ensure that a set energy cost can be achieved

 Ability to monitor actual power consumption to enable power usage modeling over time and a given planning period

 Ability to understand cooling demand from a temperature and airflow perspective

 Control capability that reduces platform power consumption to protect a server in a hot-spot

 Ability to monitor server inlet temperatures to enable greater rack utilization in areas with adequate cooling

The requirements listed above are those that are addressed by the Intel

®

C220 series chipset

Management Engine (ME) and Intel

®

Intelligent Power Node Manager (NM) technology. The

ME/NM combination is a power and thermal control capability on the platform, which exposes external interfaces that allow IT (through external management software) to query the ME about platform power capability and consumption, thermal characteristics, and specify policy directives

(for example, set a platform power budget).

Node Manager (NM) is a platform resident technology that enforces power capping and thermaltriggered power capping policies for the platform. These policies are applied by exploiting subsystem knobs (such as processor P and T states) that can be used to control power consumption. NM enables data center power management by exposing an external interface to management software through which platform policies can be specified. It also implements specific data center power management usage models such as power limiting and thermal monitoring.

The NM feature is implemented by a complementary architecture utilizing the ME, BMC, BIOS, and an ACPI-compliant OS. The ME provides the NM policy engine and power control/limiting functions (referred to as Node Manager or NM) while the BMC provides the external LAN link by which external management software can interact with the feature. The BIOS provides system power information utilized by the NM algorithms and also exports ACPI Source Language (ASL) code used by OS-Directed Power Management (OSPM) for negotiating processor P and T state

40 Revision 2.0

changes for power limiting. PMBus*-compliant power supplies provide the capability to monitoring input power consumption, which is necessary to support NM.

Following are the some of the applications of Intel

®

Intelligent Power Node Manager technology:

Platform Power Monitoring and Limiting: The ME/NM monitors platform power consumption and holds average power over duration. It can be queried to return actual power at any given instance. The power limiting capability is to allow external management software to address key IT issues by setting a power budget for each server. For example, if there is a physical limit on the power available in a room, IT can decide to allocate power to different servers based on their usage

– servers running critical systems can be allowed more power than servers that are running less critical workload.

Inlet Air Temperature Monitoring: The ME/NM monitors server inlet air temperatures periodically. If there is an alert threshold in effect, ME/NM issues an alert when the inlet

(room) temperature exceeds the specified value. The threshold value can be set by policy.

Memory Subsystem Power Limiting: The ME/NM monitors memory power consumption. Memory power consumption is estimated using average bandwidth utilization information

Processor Power monitoring and limiting: The ME/NM monitors processor or socket power consumption and holds average power over duration. It can be queried to return actual power at any given instant. The monitoring process of the ME will be used to limit the processor power consumption through processor P-states and dynamic core allocation.

Core allocation at boot time: Restrict the number of cores for OS/VMM use by limiting how many cores are active at boot time. After the cores are turned off, the CPU will limit how many working cores are visible to BIOS and OS/VMM. The cores that are turned off cannot be turned on dynamically after the OS has started. It can be changed only at the next system reboot.

Core allocation at run-time: This particular use case provides a higher level processor power control mechanism to a user at run-time, after booting. An external agent can dynamically use or not use cores in the processor subsystem by requesting ME/NM to control them, specifying the number of cores to use or not use.

Table 14. Intel

®

Value Vector

Power and Thermal

Monitoring

Capabilities and Features

Platform power monitoring

Inlet Air temperature monitoring

Processor package power monitoring

Memory power monitoring

Power Utilization Controls Platform power limiting

Processor power limiting

Memory power limiting

Dynamic core allocation (core-Idling)

Configure core power off at boot time

Configure power-optimized boot at boot time

2.0

Revision 2.0 41

Value Vector

Power and Thermal

Policies

Avoid Triggering HW

Protection

Interfaces

Capabilities and Features

Concurrent policies

Power limiting

– OS operational

Power limiting

– during OS failure

Power reduction upon temperature excursion

Response SLA

Reduce power consumption to prevent tripping DC circuit breaker

Reduce power consumption during SMART ridethrough or overcurrent

IPMI-based commands over SMBus* (monitoring, control, and alert)

16

1s(adj)

2.0

5.3.1 Hardware Requirements

NM is supported only on platforms that have the NM FW functionality loaded and enabled on the Management Engine (ME) in the SSB and that have a BMC present to support the external

LAN interface to the ME. NM power limiting feature requires a means for the ME to monitor input power consumption for the platform. This capability is generally provided by means of

PMBus*-compliant power supplies although an alternative model using a simpler SMBus* power monitoring device is possible (there is potential loss in accuracy and responsiveness using non-

PMBus* devices). The NM SmaRT/CLST feature requires specific PMBus*-compliant power supplies as well as additional hardware on the baseboard.

42 Revision 2.0

Platform Management Functional Overview

6. Platform Management Functional Overview

Platform management functionality is supported by several hardware and software components integrated on the server board that work together to control system functions, monitor and report system health, and control various thermal and performance features in order to maintain (when possible) server functionality in the event of component failure and/or environmentally stressed conditions.

This chapter provides a high level overview of the platform management features and functionality implemented on the server board. For more in depth and design level Platform

Management information, refer to the BMC Core Firmware External Product Specification (EPS) and BIOS Core External Product Specification (EPS) for Intel

®

Server products based on the

Intel

®

Xeon

®

processor E3-1200 V3/V4 product families.

6.1 Baseboard Management Controller (BMC) Firmware Feature Support

The following sections outline features that the integrated BMC firmware can support. Support or utilization for some features is dependent on the server platform in which the server board is integrated and any additional system level components and options that may be installed.

6.1.1

IPMI 2.0 Features

Baseboard management controller (BMC)

IPMI Watchdog timer

Messaging support, including command bridging and user/session support

Chassis device functionality, including power/reset control and BIOS boot flags support

Event receiver device: The BMC receives and processes events from other platform subsystems.

Field Replaceable Unit (FRU) inventory device functionality: The BMC supports access to system FRU devices using IPMI FRU commands.

System Event Log (SEL) device functionality: The BMC supports and provides access to a SEL.

Sensor Data Record (SDR) repository device functionality: The BMC supports storage and access of system SDRs.

Sensor device and sensor scanning/monitoring: The BMC provides IPMI management of sensors. It polls sensors to monitor and report system health.

IPMI interfaces

-

Host interfaces including system management software (SMS) with receive message queue support, and server management mode (SMM)

- IPMB interface

-

LAN interface that supports the IPMI-over-LAN protocol (RMCP, RMCP+)

Serial-over-LAN (SOL)

ACPI state synchronization: The BMC tracks ACPI state changes that are provided by the BIOS.

BMC self test: The BMC performs initialization and run-time self-tests and makes results available to external entities.

Revision 2.0 43

Platform Management Functional Overview

See also the Intelligent Platform Management Interface Specification Second Generation v2.0.

6.1.2 Non-IPMI Features

The BMC supports the following non-IPMI features.

In-circuit BMC firmware update

BMC FW reliability enhancements:

- Redundant BMC boot blocks to avoid possibility of a corrupted boot block resulting in a scenario that prevents a user from updating the BMC

-

BMC System Management Health Monitoring

Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality.

Enable/Disable of System Reset Due CPU Errors

Chassis intrusion detection

Fan speed control

Fan redundancy monitoring and support

Hot-swap fan support

Power Supply Fan Sensors

System Airflow Monitoring

Exit Air Temperature Monitoring

Acoustic management: Support for multiple fan profiles

Ethernet Controller Thermal Monitoring

Global Aggregate Temperature Margin Sensor

Platform environment control interface (PECI) thermal management support

Memory Thermal Management

DIMM temperature monitoring: New sensors and improved acoustic management using closed-loop fan control algorithm taking into account DIMM temperature readings

Power supply redundancy monitoring and support

Power unit management: Support for power unit sensor. The BMC handles power-good dropout conditions.

Intel

®

Intelligent Power Node Manager support

Signal testing support: The BMC provides test commands for setting and getting platform signal states.

The BMC generates diagnostic beep codes for fault conditions.

System GUID storage and retrieval

Front panel management: The BMC controls the system status LED and chassis ID LED.

It supports secure lockout of certain front panel functionality and monitors button presses.

The chassis ID LED is turned on using a front panel button or a command.

Local Control Display Panel support

Power state retention

Power fault analysis

Intel

®

Light-Guided Diagnostics

44 Revision 2.0

Platform Management Functional Overview

Address Resolution Protocol (ARP): The BMC sends and responds to ARPs (supported on embedded NICs).

Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported on embedded NICs).

E-mail alerting

Embedded web server:

-

Support for embedded web server UI in Basic Manageability feature set

- Human-readable SEL

-

Additional system configurability

- Additional system monitoring capability

-

Enhanced online help

Integrated KVM

Integrated Remote Media Redirection

Local Directory Access Protocol (LDAP) support

Sensor and SEL logging additions/enhancements (for example, additional thermal monitoring capability)

SEL Severity Tracking and the Extended SEL

Embedded platform debug feature which allows capture of detailed data for later analysis

Provisioning and inventory enhancements:

-

Inventory data/system information export (partial SMBIOS table)

DCMI 1.1 compliance (product-specific)

Management support for PMBus* rev1.2 compliant power supplies

Energy Star Server Support

Smart Ride Through (SmaRT)/Closed Loop System Throttling (CLST)

Power Supply Cold Redundancy

Power Supply FW Update

Power Supply Compatibility Check

6.2 Basic and Advanced Features

The following table lists basic and advanced feature support. Individual features may vary by platform. See the appropriate Platform Specific EPS addendum for more information.

Table 15. Basic and Advanced Features

Feature

IPMI 2.0 Feature Support

In-circuit BMC Firmware Update

FRB 2

Chassis Intrusion Detection

Fan Redundancy Monitoring

Hot-Swap Fan Support

Acoustic Management

Yes

Basic*

Yes

Yes

Yes

Yes

Yes

Yes

Advanced**

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Revision 2.0 45

Platform Management Functional Overview

Feature

Diagnostic Beep Code Support

Power State Retention

ARP/DHCP Support

Yes

Basic*

Yes

Yes

Advanced**

Yes

Yes

Yes

PECI Thermal Management Support

E-mail Alerting

Embedded Web Server

SSH Support

Integrated KVM

Integrated Remote Media Redirection

Lightweight Directory Access Protocol (LDAP)

Intel

®

Intelligent Power Node Manager

Support***

SMASH CLP

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes Yes

* Basic management features provided by Integrated BMC

**Advanced management features available with optional Intel

®

Remote Management Module 4

*** Intel

®

Intelligent Power Node Manager Support requires PMBus*-compliant power supply

6.3 Advanced Configuration and Power Interface (ACPI)

The server board supports the following ACPI states.

Table 16. ACPI Power States

S0

State

S1

S2

S3

S4

S5

Supported

Yes

Yes

No

No

No

Yes

Description

Working.

 The front panel power LED is on (not controlled by the BMC).

 The fans spin at the normal speed, as determined by sensor inputs.

 Front panel buttons work normally.

Sleeping. Hardware context is maintained; equates to processor and chipset clocks being stopped.

 The front panel power LED blinks at a rate of 1 Hz with a 50% duty cycle (not controlled by the BMC).

 The watchdog timer is stopped.

 The power, reset, front panel NMI, and ID buttons are unprotected.

 Fan speed control is determined by available SDRs. Fans may be set to a fixed state, or basic fan management can be applied.

The BMC detects that the system has exited the ACPI S1 sleep state when the BIOS

SMI handler notifies it.

Not supported.

Supported only on Workstation platforms. See appropriate Platform Specific Information for more information.

Not supported.

Soft off.

 The front panel buttons are not locked.

 The fans are stopped.

 The power-up process goes through the normal boot process.

 The power, reset, front panel NMI, and ID buttons are unlocked.

46 Revision 2.0

Platform Management Functional Overview

6.4 Power Control Sources

The server board supports several power control sources which can initiate a power-up or power-down activity.

Table 17. Power Control Initiators

Source

Power button

BMC watchdog timer

Command

Power state retention

Chipset

CPU Thermal

WOL(Wake On LAN)

External Signal Name or

Internal Subsystem

Front panel power button

Internal BMC timer

Routed through command processor

Implemented by means of BMC internal logic

Sleep S4/S5 signal (same as

POWER_ON)

CPU Thermtrip

LAN

Capabilities

Turns power on or off

Turns power off, or power cycle

Turns power on or off, or power cycle

Turns power on when AC power returns

Turns power on or off

Turns power off

Turns power on

6.5 BMC Watchdog

The BMC FW is increasingly called upon to perform system functions that are time-critical in that failure to provide these functions in a timely manner can result in system or component damage. Intel

®

S1200V3RP Server Platforms introduce a BMC watchdog feature to provide a safe-guard against this scenario by providing an automatic recovery mechanism. It also can provide automatic recovery of functionality that has failed due to a fatal FW defect triggered by a rare sequence of events or a BMC hang due to some type of HW glitch (for example, power).

This feature is comprised of a set of capabilities whose purpose is to detect misbehaving subsections of BMC firmware, the BMC CPU itself, or HW subsystems of the BMC component, and to take appropriate action to restore proper operation. The action taken is dependent on the nature of the detected failure and may result in a restart of the BMC CPU, one or more BMC

HW subsystems, or a restart of malfunctioning FW subsystems.

The BMC watchdog feature only allows up to three resets of the BMC CPU (such as HW reset) or entire FW stack (such as a SW reset) before giving up and remaining in the uBOOT code.

This count is cleared upon cycling of power to the BMC or upon continuous operation of the

BMC without a watchdog-generated reset occurring for a period of greater than 30 minutes. The

BMC FW logs a SEL event indicating that a watchdog-generated BMC reset (either soft or hard reset) has occurred. This event may be logged after the actual reset has occurred. Refer to sensor section for details for the related sensor definition. The BMC will also indicate a degraded system status on the Front Panel Status LED after a BMC HW reset or FW stack reset. This state (which follows the state of the associated sensor) will be cleared upon system reset or (AC or DC) power cycle.

Note: A reset of the BMC may result in the following system degradations that will require a system reset or power cycle to correct:

1. Timeout value for the rotation period can be set using this parameter. Potentially, there will be incorrect ACPI Power State reported by the BMC.

Revision 2.0 47

Platform Management Functional Overview

2. Reversion of temporary test modes for the BMC back to normal operational modes.

3. FP status LED and DIMM fault LEDs may not reflect BIOS detected errors.

6.6 Fault Resilient Booting (FRB)

Fault resilient booting (FRB) is a set of BIOS and BMC algorithms and hardware support that allow a multiprocessor system to boot even if the bootstrap processor (BSP) fails. Only FRB2 is supported using watchdog timer commands.

FRB2 refers to the FRB algorithm that detects system failures during POST. The BIOS uses the

BMC watchdog timer to back up its operation during POST. The BIOS configures the watchdog timer to indicate that the BIOS is using the timer for the FRB2 phase of the boot operation.

After the BIOS has identified and saved the BSP information, it sets the FRB2 timer use bit and loads the watchdog timer with the new timeout interval.

If the watchdog timer expires while the watchdog use bit is set to FRB2, the BMC (if so configured) logs a watchdog expiration event showing the FRB2 timeout in the event data bytes.

The BMC then hard resets the system, assuming the BIOS-selected reset as the watchdog timeout action.

The BIOS is responsible for disabling the FRB2 timeout before initiating the option ROM scan and before displaying a request for a boot password. If the processor fails and causes an FRB2 timeout, the BMC resets the system.

The BIOS gets the watchdog expiration status from the BMC. If the status shows an expired

FRB2 timer, the BIOS enters the failure in the system event log (SEL). In the OEM bytes entry in the SEL, the last POST code generated during the previous boot attempt is written. FRB2 failure is not reflected in the processor status sensor value.

The FRB2 failure does not affect the front panel LEDs.

6.7 Sensor Monitoring

The BMC monitors system hardware and reports system health. Some of the sensors include those for monitoring:

Component, board, and platform temperatures

Board and platform voltages

System fan presence and tach

Chassis intrusion

Front Panel NMI

Front Panel Power and System Reset Buttons

SMI timeout

Processor errors

The information gathered from physical sensors is translated into IPMI sensors as part of the

IPMI Sensor Model. The BMC also reports various system state changes by maintaining virtual sensors that are not specifically tied to physical hardware.

48 Revision 2.0

Platform Management Functional Overview

See

Appendix B

– Integrated BMC Sensor Tables

for additional sensor information.

6.8 Field Replaceable Unit (FRU) Inventory Device

The BMC implements the interface for logical FRU inventory devices as specified in the

Intelligent Platform Management Interface Specification, Version 2.0. This functionality provides commands used for accessing and managing the FRU inventory information. These commands can be delivered through all interfaces.

The BMC provides FRU device command access to its own FRU device and to the FRU devices throughout the server. The FRU device ID mapping is defined in the Platform Specific

Information. The BMC controls the mapping of the FRU device ID to the physical device.

6.9 System Event Log (SEL)

The BMC implements the system event log as specified in the Intelligent Platform Management

Interface Specification, Version 2.0. The SEL is accessible regardless of the system power state through the BMC's in-band and out-of-band interfaces.

The BMC allocates 65,502 bytes (approximately 64 KB) of non-volatile storage space to store system events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be stored at a time. Any command that results in an overflow of the SEL beyond the allocated space is rejected with an Out of Space IPMI completion code (C4h).

Events logged to the SEL can be viewed using Intel’s SELVIEW utility, Embedded Web Server, and Active System Console.

6.10 System Fan Management

The BMC controls and monitors the system fans. Each fan is associated with a fan speed sensor that detects fan failure and may also be associated with a fan presence sensor for hotswap support. For redundant fan configurations, the fan failure and presence status determines the fan redundancy sensor state.

The system fans are divided into fan domains, each of which has a separate fan speed control signal and a separate configurable fan control policy. A fan domain can have a set of temperature and fan sensors associated with it. These are used to determine the current fan domain state.

A fan domain has three states: sleep, nominal, and boost. The sleep and boost states have fixed (but configurable through OEM SDRs) fan speeds associated with them. The nominal state has a variable speed determined by the fan domain policy. An OEM SDR record is used to configure the fan domain policy.

System fan speeds are controlled through pulse width modulation (PWM) signals, which are driven separately for each domain by integrated PWM hardware. Fan speed is changed by adjusting the duty cycle, which is the percentage of time the signal is driven high in each pulse.

6.10.1 Thermal and Acoustic Management

This feature refers to enhanced fan management to keep the system optimally cooled while reducing the amount of noise generated by the system fans. Aggressive acoustics standards

Revision 2.0 49

Platform Management Functional Overview might require a trade-off between fan speed and system performance parameters that contribute to the cooling requirements, primarily memory bandwidth. The BIOS, BMC, and

SDRs work together to provide control over how this trade-off is determined.

This capability requires the BMC to access temperature sensors on the individual memory

DIMMs.

In order to maintain comprehensive thermal protection, deliver the best system acoustics, and improve fan power efficiency, an intelligent Fan Speed Control (FSC) and thermal management technology (mechanism) is used. Options in <F2> BIOS Setup (BIOS > Advanced > System

Acoustic and Performance Configuration) allow for parameter adjustments based on the actual system configuration and usage:

Set Throttling Mode

Altitude

Set Fan Profile

Fan PWM Offset

Quiet Fan Idle Mode

Note: The above features may or may not be in effective depends on the actual thermal characters of a specific system. Refer to Intel

®

Server System R1000RP product family

Technical Product Specification and Intel

®

Server System P4000RP product family Technical

Product Specification for system thermal and acoustic management.

6.10.2 Thermal Sensor Input to Fan Speed Control

The BMC uses various IPMI sensors as input to the fan speed control. Some of the sensors are

IPMI models of actual physical sensors whereas some are virtual sensors whose values are derived from physical sensors using calculations and/or tabular information.

The following IPMI thermal sensors are used as input to the fan speed control:

Front Panel Temperature Sensor

Baseboard Temperature Sensor

CPU Margin Sensors

3, 5, 6

2

1

DIMM Thermal Margin Sensors

3, 5

Exit Air Temperature Sensor

1, 4, 8

PCH Temperature Sensor

4, 6

On-board Ethernet Controller Temperature Sensors

4, 6

Add-In Intel

®

SAS/IO Module Temperature Sensors

4, 6

PSU Thermal Sensor

4, 9

CPU VR Temperature Sensors

4, 7

DIMM VR Temperature Sensors

4, 7

Integrated BMC Temperature Sensor

4, 7

Global Aggregate Thermal Margin Sensors

8

Notes:

1. For fan speed control in Intel

®

chassis

50 Revision 2.0

Platform Management Functional Overview

2. For fan speed control in 3rd party chassis

3. Temperature margin from throttling threshold

4. Absolute temperature

5. PECI value or margin value

6. On-die sensor

7. On-board sensor

8. Virtual sensor

9. Available only when PSU has PMBus*

The following illustration provides a simple model showing the fan speed control structure that implements the resulting fan speeds.

Figure 15. Fan Speed Control Process

6.10.3 Fan Profiles

The server system supports multiple fan control profiles to support acoustic targets and

American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) compliance. The BIOS Setup utility can be used to choose between meeting the target acoustic level or enhanced system performance. This is accomplished through fan profiles.

The BMC supports eight fan profiles, numbered from 0 to 7.

Type

OLTT

OLTT

OLTT

OLTT

OLTT

OLTT

OLTT

0

1

2

3

4

5

6

Profile

Table 18. Fan Profiles

Details

Acoustic, 300M altitude

Performance, 300M altitude

Acoustic, 900M altitude

Performance, 900M altitude

Acoustic, 1500M altitude

Performance, 1500M altitude

Acoustic, 3000M altitude

Revision 2.0 51

Platform Management Functional Overview

Type

OLTT

CLTT

CLTT

CLTT

CLTT

7

0

2

4

6

Profile Details

Performance, 3000M altitude

300M altitude

900M altitude

1500M altitude

3000M altitude

Each group of profiles allows for varying fan control policies based on the altitude. For a given altitude, the Tcontrol SDRs associated with an acoustics-optimized profile generate less noise than the equivalent performance-optimized profile by driving lower fan speeds, and the BIOS reduces thermal management requirements by configuring more aggressive memory throttling.

The BMC only supports enabling a fan profile through the command if that profile is supported on all fan domains defined for the given system. It is important to configure platform Sensor

Data Records (SDRs) so that all desired fan profiles are supported on each fan domain. If no single profile is supported across all domains, the BMC, by default, uses profile 0 and does not allow it to be changed.

6.10.4 Memory Thermal Throttling

The server board provides support for system thermal management through open loop throttling

(OLTT) and closed loop throttling (CLTT) of system memory. Normal system operation uses closed-loop thermal throttling (CLTT) and DIMM temperature monitoring as major factors in overall thermal and acoustics management. In the event that BIOS is unable to configure the system for CLTT, it defaults to open-loop thermal throttling (OLTT). In the OLTT mode, it is assumed that the DIMM temperature sensors are not available for fan speed control. Throttling levels are changed dynamically to cap throttling based on memory and system thermal conditions as determined by the system and DIMM power and thermal parameters. The BMC’s fan speed control functionality is linked to the memory throttling mechanism used.

The following terminology is used for the various memory throttling options:

Static Open Loop Thermal Throttling (Static-OLTT): OLTT control registers that are configured by BIOS MRC remain fixed after post. The system does not change any of the throttling control registers in the embedded memory controller during runtime.

Static Closed Loop Thermal Throttling (Static-CLTT): CLTT control registers are configured by BIOS MRC during POST. The memory throttling is run as a closed-loop system with the DIMM temperature sensors as the control input. Otherwise, the system does not change any of the throttling control registers in the embedded memory controller during runtime.

Dynamic Open Loop Thermal Throttling (Dynamic-OLTT): OLTT control registers are configured by BIOS MRC during POST. Adjustments are made to the throttling during runtime based on changes in system cooling (fan speed).

Dynamic Closed Loop Thermal Throttling (Dynamic-CLTT): CLTT control registers are configured by BIOS MRC during POST. The memory throttling is run as a closedloop system with the DIMM temperature sensors as the control input. Adjustments are made to the throttling during runtime based on changes in system cooling (fan speed).

52 Revision 2.0

Platform Management Functional Overview

Both Static and Dynamic CLTT modes implement a Hybrid Closed Loop Thermal Throttling mechanism whereby the Integrated Memory Controller estimates the DRAM temperature in between actual reads of the memory thermal sensors.

6.11 Messaging Interfaces

The BMC supports the following communications interfaces:

Host SMS interface by means of low pin count (LPC)/keyboard controller style (KCS) interface

Host SMM interface by means of low pin count (LPC)/keyboard controller style (KCS) interface

Intelligent Platform Management Bus (IPMB) I2C interface

LAN interface using the IPMI-over-LAN protocols

Every messaging interface is assigned an IPMI channel ID by IPMI 2.0. The following table shows the standard channel assignments.

Table 19. Messaging Interfaces

0

1

2

3

Channel ID Interface

No

Supports

Sessions

Yes

Yes

Yes

4

5

6

7

8

– 0Dh

0Eh

0Fh

Primary IPMB

LAN 1

LAN 2

LAN3

1

(Provided by the Intel

®

Dedicated Server

Management NIC)

Reserved

USB

2

Secondary IPMB

SMM

Reserved

Self

3

SMS/Receive Message Queue

Yes

No

No

No

No

Notes:

1. Optional hardware supported by the server system.

2. Reserve USB channel number, current BMC firmware does not support communication through a USB channel.

3. Refers to the actual channel used to send the request.

6.11.1 User Model

The BMC supports the IPMI 2.0 user model. 15 user IDs are supported. These 15 users can be assigned to any channel. The following restrictions are placed on user-related operations:

1. User names for User IDs 1 and 2 cannot be cha nged. These are always “” (Null/blank) and “root” respectively.

Revision 2.0 53

Platform Management Functional Overview

2.

User 2 (“root”) always has the administrator privilege level.

3. All user passwords (including passwords for 1 and 2) may be modified.

User IDs 3-15 may be used freely, with the condition that user names are unique. Therefore, no other users can be named “” (Null), “root,” or any other existing user name.

6.11.2 IPMB Communication Interface

The IPMB communication interface uses the 100 KB/s version of an I

2

C bus as its physical medium. For more information on I

2

C specifications, see The I

2

C Bus and How to Use It. The

IPMB implementation in the BMC is compliant with the IPMB v1.0, revision 1.0.

The BMC IPMB slave address is 20h.

The BMC both sends and receives IPMB messages over the IPMB interface. Non-IPMB messages received by means of the IPMB interface are discarded.

Messages sent by the BMC can either be originated by the BMC, such as initialization agent operation, or by another source. One example is KCS-IPMB bridging.

6.11.3 LAN Interface

The BMC implements both the IPMI 1.5 and IPMI 2.0 messaging models. These provide out-ofband local area network (LAN) communication between the BMC and the network.

See the Intelligent Platform Management Interface Specification Second Generation v2.0 for details about the IPMI-over-LAN protocol.

Run-time determination of LAN channel capabilities can be determined by both standard IPMI defined mechanisms.

6.11.3.1 RMCP/ASF Messaging

The BMC supports RMCP ping discovery in which the BMC responds with a pong message to an RMCP/ASF ping request. This is implemented per the Intelligent Platform Management

Interface Specification Second Generation v2.0.

6.11.3.2 BMC LAN Channels

The BMC supports three RMII/RGMII ports that can be used for communicating with Ethernet devices. Two ports are used for communication with the on-board NICs and one is used for communication with an Ethernet PHY located on an optional RMM4 add-in module.

6.11.3.2.1 Baseboard NICs

The on-board Ethernet controller provides support for a Network Controller Sideband Interface

(NC-SI) manageability interface. This provides a sideband high-speed connection for manageability traffic to the BMC while still allowing for a simultaneous host access to the OS if desired.

The NC-SI is a DMTF industry standard protocol for the side band management LAN interface.

This protocol provides a fast multi-drop interface for management traffic.

54 Revision 2.0

Platform Management Functional Overview

The baseboard NICs are connected to a single BMC RMII/RGMII port that is configured for RMII operation. The NC-SI protocol is used for this connection and provides a 100 Mb/s full-duplex multi-drop interface which allows multiple NICs to be connected to the BMC. The physical layer is based upon RMII, however RMII is a point-to-point bus whereas NC-SI allows 1 master and up to 4 slaves. The logical layer (configuration commands) is incompatible with RMII.

The server board provides support for a dedicated management channel that can be configured to be hidden from the host and only used by the BMC. This mode of operation is configured using a BIOS setup option.

6.11.3.2.2 Dedicated Management Channel

An additional LAN channel dedicated to BMC usage and not available to host SW is supported using an optional RMM4 add-in card. There is only a PHY device present on the RMM4 add-in card. The BMC has a built-in MAC module that uses th e RGMII interface to link with the card’s

PHY. Therefore, for this dedicated management interface, the PHY and MAC are located in different devices.

The PHY on the RMM4 connects to the BMC’s other RMII/RGMII interface (that is, the one that is not connected to the baseboard NICs). This BMC port is configured for RGMII usage.

In addition to the use of an RMM4 add-in card for a dedicated management channel, on systems that support multiple Ethernet ports on the baseboard, the system BIOS provides a setup option to allow one of these baseboard ports to be dedicated to the BMC for manageability purposes. When this is enabled, that port is hidden from the OS.

6.11.3.2.3 Concurrent Server Management Use of Multiple Ethernet Controllers

The BMC FW supports concurrent OOB LAN management sessions for the following combination:

2 on-board NIC ports

1 on-board NIC and the optional dedicated RMM4 add-in management NIC

2 on-board NICs and optional dedicated RMM4 add-in management NIC

All NIC ports must be on different subnets for the concurrent usage models above.

MAC addresses are assigned for management NICs from a pool of up to 3 MAC addresses allocated specifically for manageability.

The server board has seven MAC addresses programmed at the factory. MAC addresses are assigned as follows:

NIC 1 MAC address (for OS usage)

NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage)

BMC LAN channel 1 MAC address = NIC1 MAC address + 2

BMC LAN channel 2 MAC address = NIC1 MAC address + 3

BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 4

Revision 2.0 55

Platform Management Functional Overview

The printed MAC address on the server board and/or server system is assigned to NIC1 on the server board.

For security reasons, embedded LAN channels have the following default settings:

IP Address: Static

All users disabled

IPMI-enabled network interfaces may not be placed on the same subnet. This includes the

Intel

®

Dedicated Server Management NIC and either of the BMC’s embedded network interfaces.

Host-BMC communication over the same physical LAN connection

– also known as loopback – is not supported. This includes ping operations.

On server boards with more than two onboard NIC ports, only the first two ports can be used as

BMC LAN channels. The remaining ports have no BMC connectivity.

Maximum bandwidth supported by BMC LAN channels are as follows:

BMC LAN1 (Baseboard NIC port)

– 100Mb (10Mb in DC off state)

BMC LAN 2 (Baseboard NIC port)

– 100Mb (10Mb in DC off state)

BMC LAN 3 (Dedicated NIC)

– 1000Mb

6.11.3.3 IPV6 Support

In addition to IPv4, the server board supports IPv6 for manageability channels. Configuration of

IPv6 is provided by extensions to the IPMI Set and Get LAN Configuration Parameters commands as well as through a Web Console IPv6 configuration web page.

The BMC supports IPv4 and IPv6 simultaneously so they are both configured separately and completely independently. For example, IPv4 can be DHCP configured while IPv6 is statically configured or vice versa.

The parameters for IPv6 are similar to the parameters for IPv4 with the following differences:

An IPv6 address is 16 bytes vs. 4 bytes for IPv4.

An IPv6 prefix is 0 to 128 bits whereas IPv4 has a 4 byte subnet mask.

The IPv6 Enable parameter must be set before any IPv6 packets are sent or received on that channel.

There are two variants of automatic IP Address Source configuration vs. just DHCP for

IPv4.

The three possible IPv6 IP Address Sources for configuring the BMC are:

Static (Manual): The IP, Prefix, and Gateway parameters are manually configured by the user. The BMC ignores any Router Advertisement messages received over the network.

DHCPv6: The IP comes from running a DHCPv6 client on the BMC and receiving the IP from a DHCPv6 server somewhere on the network. The Prefix and Gateway are

56 Revision 2.0

Platform Management Functional Overview configured by Router Advertisements from the local router. The IP, Prefix, and Gateway are read-only parameters to the BMC user in this mode.

Stateless auto-config: The Prefix and Gateway are configured by the router through

Router Advertisements. The BMC derives its IP in two parts: the upper network portion comes from the router and the lower un ique portion comes from the BMC’s channel

MAC address. The 6-byte MAC address is converted into an 8-byte value per the EUI-

64* standard. For example, a MAC value of 00:15:17:FE:2F:62 converts into a EUI-64 value of 215:17ff:fefe:2f62. If the BMC receives a Router Advertisement from a router at

IP 1:2:3:4::1 with a prefix of 64, it would then generate for itself an IP of

1:2:3:4:215:17ff:fefe:2f62. The IP, Prefix, and Gateway are read-only parameters to the

BMC user in this mode.

IPv6 can be used with the B

MC’s Web Console, JViewer* (remote KVM and Media), and

Systems Management Architecture for Server Hardware

– Command Line Protocol (SMASH-

CLP) interface (ssh). There is no standard yet on how IPMI RMCP or RMCP+ should operate over IPv6 so that is not currently supported.

6.11.3.4 LAN Failover

The BMC FW provides a LAN failover capability so that the failure of the system HW associated with one LAN link will result in traffic being rerouted to an alternate link. This functionality is configurable using IPMI methods a s well as the BMC’s Embedded UI, allowing for user to specify the physical LAN links constitute the redundant network paths or physical LAN links constitute different network paths. BMC supports only an all or nothing approach

– that is, all interfaces bonded together, or none are bonded together.

The LAN Failover feature applies only to BMC LAN traffic. It bonds all available Ethernet devices but only one is active at a time. When enabled, if the active connection’s leash is lost, one of the secondary connections is automatically configured so that it has the same IP address.

Traffic immediately resumes on the new active connection.

The LAN Failover enable/disable command may be sent at any time. After it has been enabled, standard IPMI commands for setting channel configuration that specify a LAN channel other than the first will return an error code.

6.11.3.5 BMC IP Address Configuration

Enabling the BMC’s network interfaces requires using the Set LAN Configuration Parameter command to configure LAN configuration parameter 4, IP Address Source. The BMC supports this parameter as follows:

1h, static address (manually configured): Supported on all management NICs. This is the BMC’s default value.

2h, address obtained by BMC running DHCP: Supported only on embedded management NICs.

IP Address Source value 4h, address obtained by BMC running other address assignment protocol, is not supported on any management NIC.

Attempting to set an unsupported IP address source value has no effect, and the BMC returns error code 0xCC, Invalid data field-in request. Note that values 0h and 3h are no longer supported, and will return a 0xCC error completion code.

Revision 2.0 57

Platform Management Functional Overview

6.11.3.5.1 Static IP Address (IP Address Source Values 0h, 1h, and 3h)

The BMC supports static IP address assignment on all of its management NICs. The IP address source parameter must be set to static before the IP address; the subnet mask or gateway address can be manually set.

The BMC takes no special action when the following IP address source is specified as the IP address source for any management NIC:1h

– Static address (manually configured).

The Set LAN Configuration Parameter command must be used to configure LAN configuration parameter 3, IP Address, with an appropriate value.

The BIOS does not monitor the value of this parameter, and it does not execute DHCP for the

BMC under any circumstances, regardless of the BMC configuration.

6.11.3.5.2 Static LAN Configuration Parameters

When the IP Address Configuration parameter is set to 01h (static), the following parameters may be changed by the user:

LAN configuration parameter 3 (IP Address)

LAN configuration parameter 6 (Subnet Mask)

LAN configuration parameter 12 (Default Gateway Address)

When changing from DHCP to Static configuration, the initial values of these three parameters will be equivalent to the existing DHCP-set parameters. Additionally, the BMC observes the following network safety precautions:

1. The user may only set a subnet mask that is valid, per IPv4 and RFC 950 (Internet

Standard Subnetting Procedure). Invalid subnet values return a 0xCC (Invalid Data Field in Request) completion code, and the subnet mask is not set. If no valid mask has been previously set, default subnet mask is 0.0.0.0.

2. The user may only set a default gateway address that can potentially exist within the subnet specified above. Default gateway addresses outside the BMC’s subnet are technically unreachable and the BMC will not set the default gateway address to an unreachable value. The BMC returns a 0xCC (Invalid Data Field in Request) completion code for default gateway addresses outside its subnet.

3.

If a command is issued to set the default gateway IP address before the BMC’s IP address and subnet mask are set, the default gateway IP address is not updated and the

BMC returns 0xCC.

If the BMC’s IP address on a LAN channel changes while a LAN session is in progress over that channel, the BMC does not take action to close the session except through a normal session timeout. The remote client must re-sync with the new IP add ress. The BMC’s new IP address is only available in-band through the Get LAN Configuration Parameters command.

6.11.3.5.3 Enabling/Disabling Dynamic Host Configuration (DHCP) Protocol

The BMC DHCP feature is activated by using the Set LAN Configuration Parameter command to set LAN configuration parameter 4, IP Address Sourc e, to 2h: “address obtained by BMC

58 Revision 2.0

Platform Management Functional Overview running DHCP”. Once this parameter is set, the BMC initiates the DHCP process within approximately 100 ms.

If the BMC has previously been assigned an IP address through DHCP or the Set LAN

Configuration Parameter command, it requests that same IP address to be reassigned. If the

BMC does not receive the same IP address, system management software must be reconfigured to use the new IP address. The new address is only available in-band, through the

IPMI Get LAN Configuration Parameters command.

Changing the IP Address Source parameter from 2h to any other supported value will cause the

BMC to stop the DHCP process. The BMC uses the most recently obtained IP address until it is reconfigured.

If the physical LAN connection is lost (that is, the cable is unplugged), the BMC will not reinitiate the DHCP process when the connection is re-established.

6.11.3.5.4 DHCP-related LAN Configuration Parameters

Users may not change the following LAN parameters while the DHCP is enabled:

LAN configuration parameter 3 (IP Address)

LAN configuration parameter 6 (Subnet Mask)

LAN configuration parameter 12 (Default Gateway Address)

To prevent users from disrupting the BMC’s LAN configuration, the BMC treats these parameters as read-only while DHCP is enabled for the associated LAN channel. Using the Set

LAN Configuration Parameter command to attempt to change one of these parameters under such circumstances has no effect, and the BMC returns e rror code 0xD5, “Cannot Execute

Command. Command, or request parameter(s) are not supported in present state.”

6.11.3.6 DHCP BMC Hostname

The BMC allows setting a DHCP Hostname using the Set/Get LAN Configuration Parameters command.

DHCP Hostname can be set regardless of the IP Address source configured on the BMC.

But this parameter is only used if the IP Address source is set to DHCP.

When Byte 2 is set to Update in progress, all the 16 Block Data Bytes (Bytes 3

– 18) must be present in the request.

When Block Size is less than 16, it must be the last Block request in this series. In other words Byte 2 is equal to Update is complete on that request.

Whenever Block Size is less than 16, the Block data bytes must end with a NULL

Character or Byte (=0).

All Block write requests are updated into a local Memory byte array. When Byte 2 is set to Update is Complete, the Local Memory is committed to the NV Storage. Local

Memory is reset to NULL after changes are committed.

When Byte 1 (Block Selector = 1), firmware resets all the 64 bytes local memory. This can be used to undo any changes after the last Update in Progress.

Revision 2.0 59

Platform Management Functional Overview

User should always set the hostname starting from block selector 1 after the last Update

is complete. If the user skips block selector 1 while setting the hostname, the BMC will record the hostname as NULL, because the first block contains NULL data.

This scheme effectively does not allow a user to make a partial Hostname change. Any

Hostname change needs to start from Block 1.

Byte 64 ( Block Selector 04h byte 16) is always ignored and set to NULL by BMC which effectively means we can set only 63 bytes.

User is responsible for keeping track of the Set series of commands and Local Memory contents.

While BMC firmware is in Set Hostname in Progress (Update not complete), the firmware continues using the Previous Hostname for DHCP purposes.

6.11.4 Address Resolution Protocol (ARP)

The BMC can receive and respond to ARP requests on BMC NICs. Gratuitous ARPs are supported, and disabled by default.

6.11.5 Internet Control Message Protocol (ICMP)

The BMC supports the following ICMP message types targeting the BMC over integrated NICs:

Echo request (ping): The BMC sends an Echo Reply.

Destination unreachable: If message is associated with an active socket connection within the BMC, the BMC closes the socket.

6.11.6 Virtual Local Area Network (VLAN)

The BMC supports VLAN as defined by IPMI 2.0 specifications. VLAN is supported internally by the BMC, not through switches. VLAN provides a way of grouping a set of systems together so that they form a logical network. This feature can be used to set up a management VLAN where only devices which are members of the VLAN will receive packets related to management and members of the VLAN will be isolated from any other network traffic. Note that VLAN does not change the behavior of the host network setting, and it only affects the BMC LAN communication.

LAN configuration options are now supported (by means of the Set LAN Config Parameters command, parameters 20 and 21) that allow support for 802.1Q VLAN (Layer 2). This allows

VLAN headers/packets to be used for IPMI LAN sessions. VLAN IDs are entered and enabled by means of parameter 20 of the Set LAN Config Parameters IPMI command. When a VLAN ID is configured and enabled, the BMC only accepts packets with that VLAN tag/ID. Conversely, all

BMC generated LAN packets on the channel include the given VLAN tag/ID. Valid VLAN IDs are 1 through 4094, and VLAN IDs of 0 and 4095 are reserved, per the 802.1Q VLAN specification. Only one VLAN can be enabled at any point in time on a LAN channel. If an existing VLAN is enabled, it must first be disabled prior to configuring a new VLAN on the same

LAN channel.

Parameter 21 (VLAN Priority) of the Set LAN Config Parameters IPMI command is now implemented and a range from 0 to 7 will be allowed for VLAN Priorities. Note that bits 3 and 4 of Parameter 21 are considered Reserved bits.

60 Revision 2.0

Platform Management Functional Overview

Parameter 25 (VLAN Destination Address) of the Set LAN Config Parameters IPMI command is not supported and returns a completion code of 0x80 (parameter not supported) for any read/write of parameter 25.

If the BMC IP address source is DHCP, the following behavior is seen:

If the BMC is first configured for DHCP (prior to enabling VLAN), when VLAN is enabled, the BMC performs a discovery on the new VLAN in order to obtain a new BMC IP address.

If the BMC is configured for DHCP (before disabling VLAN), when VLAN is disabled, the

BMC performs a discovery on the LAN in order to obtain a new BMC IP address.

If the BMC IP address source is Static, the following behavior is seen:

If the BMC is first configured for static (prior to enabling VLAN), when VLAN is enabled, the BMC has the same IP address as configured before. It is left to the management application to configure a different IP address if that is not suitable for VLAN.

If the BMC is configure for static (prior to disabling VLAN), when VLAN is disabled, the

BMC has the same IP address as configured before. It is left to the management application to configure a different IP address if that is not suitable for LAN.

6.11.7 Secure Shell (SSH)

Secure Shell (SSH) connections are supported for SMASH-CLP sessions to the BMC.

6.11.8 Serial-over-LAN (SOL 2.0)

The BMC supports IPMI 2.0 SOL.

IPMI 2.0 introduced a standard serial-over-LAN feature. This is implemented as a standard payload type (01h) over RMCP+.

Three commands are implemented for SOL 2.0 configuration:

Get SOL 2.0 Configuration Parameters and Set SOL 2.0 Configuration Parameters:

These commands are used to get and set the values of the SOL configuration parameters. The parameters are implemented on a per-channel basis.

Activating SOL: This command is not accepted by the BMC. It is sent by the BMC when

SOL is activated to notify a remote client of the switch to SOL.

Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is used, it should be negotiated when the IPMI-over LAN session is established.

6.11.9 Platform Event Filter (PEF)

The BMC includes the ability to generate a selectable action, such as a system power-off or reset, when a match occurs to one of a configurable set of events. This capability is called

Platform Event Filtering, or PEF. One of the available PEF actions is to trigger the BMC to send a LAN alert to one or more destinations.

The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table are preconfigured (but may be changed by the user). The remaining entries are left blank, and may be configured by the user.

Revision 2.0 61

Platform Management Functional Overview

5

6

7

8

1

Event Filter

Number

2

3

4

9

10

11

12

Table 20. Factory Configured PEF Table Entries

Offset Mask

Non-critical, critical and nonrecoverable

Non-critical, critical and nonrecoverable

Non-critical, critical and nonrecoverable

General chassis intrusion

Events

Temperature sensor out of range

Voltage sensor out of range

Fan failure

Failure and predictive failure

Uncorrectable ECC

POST error

FRB2

Policy Correction Time

Power down, power cycle, and reset

OEM system boot event

Drive Failure, Predicted Failure

Chassis intrusion (security violation)

Power supply failure

BIOS

BIOS: POST code error

Watchdog Timer expiration for

FRB2

Node Manager

Watchdog timer

System restart (reboot)

Hot Swap Controller

Additionally, the BMC supports the following PEF actions:

Power off

Power cycle

Reset

OEM action

Alerts

The Diagnostic interrupt action is not supported.

6.11.10 LAN Alerting

The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps), and SMTP email alerts.

The BMC supports a minimum of four LAN alert destinations.

6.11.10.1 SNMP Platform Event Traps (PETs)

This feature enables a target system to send SNMP traps to a designated IP address by means of LAN. These alerts are formatted per the Intelligent Platform Management Interface

Specification Second Generation v2.0. A Modular Information Block (MIB) file associated with the traps is provided with the BMC firmware to facilitate interpretation of the traps by external software. The format of the MIB file is covered under RFC 2578.

62 Revision 2.0

Platform Management Functional Overview

6.11.11 Alert Policy Table

Associated with each PEF entry is an alert policy that determines which IPMI channel the alert is to be sent. There is a maximum of 20 alert policy entries. There are no pre-configured entries in the alert policy table because the destination types and alerts may vary by user. Each entry in the alert policy table contains four bytes for a maximum table size of 80 bytes.

6.11.11.1 E-mail Alerting

The Embedded Email Alerting feature allows the user to receive e-mails alerts indicating issues with the server. This allows e-mail alerting in an OS-absent (for example, Pre-OS and OS-Hung) situation. This feature provides support for sending e-mail by means of SMTP, the Simple Mail

Transport Protocol as defined in Internet RC 821. The e-mail alert provides a text string that describes a simple description of the event. SMTP alerting is configured using the embedded web server.

6.11.12 SM-CLP (SM-CLP Lite)

SMASH refers to Systems Management Architecture for Server Hardware. SMASH is defined by a suite of specifications, managed by the DMTF, that standardize the manageability interfaces for server hardware. CLP refers to Command Line Protocol. SM-CLP is defined by the Server Management Command Line Protocol Specification (SM-CLP) ver1.0, which is part of the SMASH suite of specifications. The specifications and further information on SMASH can be found at the DMTF website ( http://www.dmtf.org/ ).

The BMC provides an embedded lite version of SM-CLP that is syntax-compatible but not considered fully compliant with the DMTF standards.

The SM-CLP utilized by a remote user by connecting a remote system using one of the system

NICs. It is possible for third party management applications to create scripts using this CLP and execute them on server to retrieve information or perform management tasks such as reboot the server, configure events, and so on.

The BMC embedded SM-CLP feature includes the following capabilities:

Power on/off/reset the server.

Get the system power state.

Clear the System Event Log (SEL).

Get the interpreted SEL in a readable format.

Initiate/terminate a Serial Over LAN session.

Support “help” to provide helpful information.

Get/set the system ID LED.

Get the system GUID.

Get/set configuration of user accounts.

Get/set configuration of LAN parameters.

Embedded CLP communication should support SSH connection.

Provide current status of platform sensors including current values. Sensors include voltage, temperature, fans, power supplies, and redundancy (power unit and fan redundancy).

Revision 2.0 63

Platform Management Functional Overview

The embedded web server is supported over any system NIC port that is enabled for server management capabilities.

6.11.13 Embedded Web Server

BMC Base manageability provides an embedded web server and an OEM-customizable web

GUI which exposes the manageability features of the BMC base feature set. It is supported over all on-board NICs that have management connectivity to the BMC as well as an optional RMM4 dedicated add-in management NIC. At least two concurrent web sessions from up to two different users is supported. The embedded web user interface supports the following client web browsers:

Microsoft Internet Explorer 7.0*

Microsoft Internet Explorer 8.0*

Microsoft Internet Explorer 9.0*

Mozilla Firefox 3.0*

Mozilla Firefox 3.5*

Mozilla Firefox 3.6*

The embedded web user interface supports strong security (authentication, encryption, and firewall support) since it enables remote server configuration and control. Embedded web server uses ports #80 and #443. The user interface presented by the embedded web user interface authenticates the user before allowing a web session to be initiated. Encryption using 128-bit

SSL is supported. User authentication is based on user id and password.

The GUI presented by the embedded web server authenticates the user before allowing a web session to be initiated. It presents all functions to all users but grays-out those functions that the user does not have privilege to execute. (For example, if a user does not have privilege to power control, the item will be displayed in greyout font in that user’s UI display). The web GUI also provides a launch point for some of the advanced features, such as KVM and media redirection. These features are grayed out in the GUI unless the system has been updated to support these advanced features.

Additional features supported by the web GUI includes:

Present all the Basic features to the users.

Power on/off/reset the server and view current power state.

Display BIOS, BMC, ME, and SDR version information.

Display overall system health.

Configuration of various IPMI over LAN parameters for both IPV4 and IPV6.

Configuration of alerting (SNMP and SMTP).

Display system asset information for the product, board, and chassis.

Display of BMC-owned sensors (name, status, current reading, enabled thresholds), including color-code status of sensors.

Provide ability to filter sensors based on sensor type (Voltage, Temperature, Fan, and

Power supply related).

Automatic refresh of sensor data with a configurable refresh rate.

64 Revision 2.0

Platform Management Functional Overview

Online help.

Display/clear SEL (display is in easily understandable human readable format).

Support major industry-standard browsers (Microsoft Internet Explorer* and Mozilla

Firefox*).

Automatically log out after user-configurable inactivity period.

The GUI session automatically times-out after a user-configurable inactivity period. By default, this inactivity period is 30 minutes.

Virtual Front Panel: The Virtual Front Panel provides the same functionality as the local front panel. The displayed LEDs match the current state of the local panel LEDs. The displayed buttons (for example, power button) can be used in the same manner as the local buttons.

Severity level indication of SEL events: The web server UI displays the severity level associated with each event in the SEL. The severity level correlates with the front panel system status LED (OK, Degraded, Non-Fatal, or Fatal).

Display of ME sensor data. Only sensors that have associated SDRs loaded are displayed.

Ability to save the SEL to a file.

Ability to force HTTPS connectivity for greater security. This is provided through a configuration option in the UI.

Display of processor and memory information as is available over IPMI over LAN.

Ability to get and set Node Manager (NM) power policies.

Display of power consumed by the server.

Ability to view and configure VLAN settings.

Warn user the reconfiguration of IP address will cause disconnect.

Capability to block logins for a period of time after several consecutive failed login attempts. The lock-out period and the number of failed logins that initiates the lock-out period are configurable by the user.

Server Power Control: Ability to force into Setup on a reset.

6.11.14 Virtual Front Panel

Virtual Front Panel is the module present as Virtual Front Panel on the left side in the embedded web server when remote Control tab is clicked.

Embedded Platform Debug feature: Allows the user to initiate a diagnostic dump to a file that can be sent to Intel for debug purposes.

Main Purpose of the Virtual Front Panel is to provide the front panel functionality virtually.

Virtual Front Panel (VFP) will mimic the status LED and Power LED status and Chassis

ID alone. It is automatically in sync with BMC every 40 seconds.

For any abnormal status LED state, Virtual Front Panel will get the reason behind the abnormal or status LED changes and displayed in VFP side.

As Virtual Front Panel uses the Chassis Control command for power actions. It won’t log the Front button press event since Logging the front panel press event for Virtual Front

Panel press will mislead the administrator.

For Reset from Virtual Front Panel, the reset will be done by a Chassis Control command.

Revision 2.0 65

Platform Management Functional Overview

For Reset from Virtual Front Panel, the restart cause will be because of Chassis Control command.

During Power action, Power button/Reset button will not accept the next action until current Power action is complete and the acknowledgment from BMC is received.

EWS will provide a valid message during Power action until it completes the current

Power action.

The VFP does not have any effect on whether the front panel is locked by Set Front

Panel Enables command.

The chassis ID LED provides a visual indication of a system being serviced. The state of the chassis ID LED is affected by the following actions:

-

Toggled by turning the chassis ID button on or off.

- There is no precedence or lock-out mechanism for the control sources. When a new request arrives, previous requests are terminated. For example, if the chassis ID button is pressed, the chassis ID LED changes to solid on. If the button is pressed again, the chassis ID LED turns off.

-

Note that the chassis ID will turn on because of the original chassis ID button press and will reflect in the Virtual Front Panel after VFP sync with BMC. Virtual Front

Panel will not reflect the chassis LED software blinking from the software command as there is no mechanism to get the chassis ID Led status.

-

Only Infinite chassis ID ON/OFF from the software command will reflect in EWS during automatic /manual EWS sync up with BMC.

Virtual Front Panel help is available for virtual panel module.

At present, NMI button in VFP is disabled. It can be used in future.

6.11.15 Embedded Platform Debug

The Embedded Platform Debug feature supports capturing low-level diagnostic data (applicable

MSRs, PCI config-space registers, and so on). This feature allows a user to export this data into a file that is retrievable from the embedded web GUI, as well as through host and remote IPMI methods, for the purpose of sending to an Intel engineer for an enhanced debugging capability.

The files are compressed, encrypted, and password protected. The file is not meant to be viewable by the end user but rather to provide additional debugging capability to an Intel support engineer.

A list of data that may be captured using this feature includes but is not limited to:

Platform sensor readings

– This includes all readable sensors that can be accessed by the BMC FW and have associated SDRs populated in the SDR repository. This does not include any event-only sensors. (All BIOS sensors and some BMC and ME sensors are event-only; meaning that they are not readable using an IPMI Get Sensor Reading command but rather are used just for event logging purposes).

SEL

– The current SEL contents are saved in both hexadecimal and text format.

CPU/memory register data

– Useful for diagnosing the cause of the following system errors: CATERR, ERR[2], SMI timeout, PERR, and SERR. The debug data is saved and timestamped for the last 3 occurrences of the error conditions.

-

PCI error registers

-

MSR registers

-

MCH registers

66 Revision 2.0

Platform Management Functional Overview

BMC configuration data

-

BMC FW debug log (that is, SysLog)

– Captures FW debug messages.

- Non-volatile storage of captured data

– Some of the captured data is stored persistently in the BMC’s non-volatile flash memory and preserved across AC power cycles. Due to size limitations of the BMC’s flash memory, it is not feasible to store all of the data persistently.

SMBIOS table data

– The entire SMBIOS table is captured from the last boot.

PCI configuration data for on-board devices and add-in cards

– The first 256 bytes of

PCI configuration data is captured for each device for each boot.

System memory map

– The system memory map is provided by BIOS on the current boot. This includes the EFI memory map and the Legacy (E820) memory map depending on the current boot.

Power supplies debug capability

-

Capture of power supply black box data and power supply asset information

–Power supply vendors are adding the capability to store debug data within the power supply itself. The platform debug feature provides a means to capture this data for each installed power supply. The data can be analyzed by Intel for failure analysis and possibly provided to the power supply vendor as well. The BMC gets this data from the power supplied from the PMBus* manufacturer-specific commands.

-

Storage of system identification in power supply

– The BMC copies board and system serial numbers and part numbers into the power supply whenever a new power supply is installed in the system or when the system is first powered on. This information is included as part of the power supply black box data for each installed power supply.

Accessibility through IPMI interfaces

– The platform debug file can be accessed using an external IPMI interface (KCS or LAN).

POST code sequence for the two most recent boots

– This is a best-effort data collection by the BMC as the BMC real-time response cannot guarantee that all POST codes are captured.

Support for multiple debug files

–The platform debug feature provides the ability to save data to two separate files that are encrypted with different passwords.

- File #1 is strictly for viewing by Intel engineering and may contain BMC log messages (that is, syslog) and other debug data that Intel FW developers deem useful in addition to the data specified in this document.

-

File #2 can be viewed by Intel partners who have signed an NDA with Intel and its contents are restricted to specific data items specified in this with the exception of the BMC syslog messages and power supply black box data.

6.11.15.1 Output Data Format

The diagnostic feature outputs a password-protected compressed HTML file containing specific

BMC and system information. This file is not intended for end-customer usage. This file is for customer support and engineering only.

6.11.15.2 Output Data Availability

The diagnostic data is available on-demand from the embedded web server, KCS, or IPMI Over

LAN commands.

Revision 2.0 67

Platform Management Functional Overview

6.11.15.3 Output Data Categories

The following tables list the data to be provided in the diagnostic output.

Category

Internal BMC Data

External BMC Data

External BIOS Data

System Data

Table 21. Diagnostic Data

Data

BMC uptime/load

Process list

Free Memory

Detailed Memory List

Filesystem List/Info

BMC Network Info

BMC Syslog

BMC Configuration Data

Hex SEL listing

Human-readable SEL listing

Human-readable sensor listing

BIOS configuration settings

POST codes for the two most recent boots

SMBIOS table for the current boot

256 bytes of PCI config data for each PCI device

Memory Map (EFI and Legacy) for current boot

Table 22. Additional Diagnostics on Error

Category

System Data

Data

First 256 bytes of PCI config data for each PCI device

PCI error registers

MSR registers

MCH registers

6.11.16 Data Center Management Interface (DCMI)

The DCMI Specification is an emerging standard that is targeted to provide a simplified management interface for Internet Portal Data Center (IPDC) customers. It is expected to become a requirement for server platforms which are targeted for IPDCs. DCMI is an IPMIbased standard that builds upon a set of required IPMI standard commands by adding a set of

DCMI-specific IPMI OEM commands. Intel

®

S1400/S1600/S2400/S2600 Server Platforms implement the mandatory DCMI features in the BMC firmware (DCMI 1.1 Errata 1 compliance).

Refer to DCMI 1.1 errata 1 spec for details. Only mandatory commands are supported. No support for optional DCMI commands. Optional power management and SEL roll over feature is not supported. DCMI Asset tag is independent of baseboard FRU asset Tag. Refer to table

DCMI Group Extension Commands for more details on DCMI commands.

68 Revision 2.0

Platform Management Functional Overview

6.11.17 Lightweight Directory Authentication Protocol (LDAP)

The Lightweight Directory Access Protocol (LDAP) is an application protocol supported by the

BMC for the purpose of authentication and authorization. The BMC user connects with an LDAP server for login authentication. This is only supported for non-IPMI logins including the embedded web UI and SM-CLP. IPMI users/passwords and sessions are not supported over

LDAP. LDAP can be configured (IP address of LDAP server, port, and so on) using the BMC’s

Embedded Web UI. LDAP authentication and authorization is supported over the any NIC configured for system management. The BMC uses a standard Open LDAP implementation for

Linux*. Only open LDAP is supported by BMC. Microsoft Windows* and Novell* LDAP are not supported.

Revision 2.0 69

Advanced Management Feature Support (RMM4)

7. Advanced Management Feature Support (RMM4)

The integrated baseboard management controller has support for advanced management features which are enabled when an optional Intel

®

Remote Management Module 4 (RMM4) is installed.

RMM4 is comprised of two boards: RMM4 lite and the optional Dedicated Server Management

NIC (DMN).

Table 23. RMM4 Option Kits

Product Code

AXXRMM4LITE

Description

Intel

®

Remote Management

Module 4 Lite

Kit Contents

RMM4 Lite Activation Key

Benefits

Enables KVM and media redirection from the onboard

NIC.

AXXRMM4 Intel

®

Remote Management

Module 4

RMM4 Lite Activation Key

Dedicated NIC Port Module

Dedicated NIC for management traffic. Higher bandwidth connectivity for

KVM and media Redirection with 100Mbe NIC.

On the server board each Intel

®

RMM4 component is installed at the following locations.

70

Figure 16. Intel

®

Revision 2.0

Advanced Management Feature Support (RMM4)

Figure 17. Intel

®

Table 24. Enabling Advanced Management Features

Manageability Hardware

Intel

®

Integrated BMC

Intel

®

Remote Management Module 4

– Lite

Package contains one module

 Key for advance Manageability features.

Intel

®

Remote Management Module 4

Package includes 2 modules

 key for advance features

 Dedicated NIC (1Gbe) for management

Benefits

Comprehensive IPMI based base manageability features

No dedicated NIC for management

Enables KVM and media redirection from onboard

NIC

Dedicated NIC for management traffic. Higher bandwidth connectivity for KVM and media

Redirection with 1Gbe NIC.

If the optional Dedicated Server Management NIC is not used then the traffic can only go through the onboard Integrated BMC-shared NIC and will share network bandwidth with the host system. Advanced manageability features are supported over all NIC ports enabled for server manageability.

7.1 Keyboard, Video, and Mouse (KVM) Redirection

The BMC firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This feature is available remotely from the embedded web server as a Java applet. This feature is only enabled when the Intel

®

RMM4 lite is present. The client system must have a Java Runtime

Environment* (JRE*) version 6.0 or later to run the KVM or media redirection applets.

The BMC supports an embedded KVM application (Remote Console) that can be launched from the embedded web server from a remote console. USB1.1 or USB 2.0 based mouse and

Revision 2.0 71

Advanced Management Feature Support (RMM4) keyboard redirection are supported. It is also possible to use the KVM-redirection (KVM-r) session concurrently with media-redirection (media-r). This feature allows a user to interactively use the keyboard, video, and mouse functions of the remote server as if the user were physically at the managed server.

KVM redirection console supports the following keyboard layouts: English, Dutch, French,

German, Italian, Russian, and Spanish.

KVM redirection includes a soft keyboard function. The soft keyboard is used to simulate an entire keyboard that is connected to the remote system. The soft keyboard functionality supports the following layouts: English, Dutch, French, German, Italian, Russian, and Spanish.

The KVM-redirection feature automatically senses video resolution for best possible screen capture and provides high-performance mouse tracking and synchronization. It allows remote viewing and configuration in pre-boot POST and BIOS setup, once BIOS has initialized video.

Other attributes of this feature include:

Encryption of the redirected screen, keyboard, and mouse

Compression of the redirected screen

Ability to select a mouse configuration based on the OS type

Supports user definable keyboard macros

KVM redirection feature supports the following resolutions and refresh rates:

7.1.1

640x480 at 60Hz, 72Hz, 75Hz, 85Hz, 100Hz

800x600 at 60Hz, 72Hz, 75Hz, 85Hz

1024x768 at 60Hx, 72Hz, 75Hz, 85Hz

1280x960 at 60Hz

1280x1024 at 60Hz

1600x1200 at 60Hz

1920x1080 (1080p),

1920x1200 (WUXGA)

1650x1080 (WSXGA+)

Remote Console

The Remote Console is the redirected screen, keyboard and mouse of the remote host system.

To use the Remote Console window of your managed host system, the browser must include a

Java* Runtime Environment plug-in. If the browser has no Java support, such as with a small handheld device, the user can maintain the remote host system using the administration forms displayed by the browser.

The Remote Console window is a Java Applet that establishes TCP connections to the BMC.

The protocol that is run over these connections is a unique KVM protocol and not HTTP or

HTTPS. This protocol uses ports #7578 for KVM, #5120 for CDROM media redirection, and

#5123 for Floppy/USB media redirection. When encryption is enabled, the protocol uses ports

#7582 for KVM, #5124 for CDROM media redirection, and #5127 for Floppy/USB media redirection. The local network environment must permit these connections to be made, that is,

72 Revision 2.0

Advanced Management Feature Support (RMM4) the firewall and, in case of a private internal network, the NAT (Network Address Translation) settings have to be configured accordingly.

7.1.2 Performance

The remote display accurately represents the local display. The feature adapts to changes to the video resolution of the local display and continues to work smoothly when the system transitions from graphics to text or vice versa. The responsiveness may be slightly delayed depending on the bandwidth and latency of the network.

Enabling KVM and/or media encryption will degrade performance. Enabling video compression provides the fastest response while disabling compression provides better video quality.

For the best possible KVM performance, a 2Mb/sec link or higher is recommended.

The redirection of KVM over IP is performed in parallel with the local KVM without affecting the local KVM operation.

7.1.3 Security

The KVM redirection feature supports multiple encryption algorithms, including RC4 and AES.

The actual algorithm that is used is negotiated with the client based on the client’s capabilities.

7.1.4 Availability

The remote KVM session is available even when the server is powered-off (in stand-by mode).

No re-start of the remote KVM session is required during a server reset or power on/off. A BMC reset (for example, due to a BMC Watchdog initiated reset or BMC reset after BMC FW update) requires the session to be re-established.

KVM sessions persist across system reset, but not across an AC power loss.

7.1.5 Usage

As the server is powered up, the remote KVM session displays the complete BIOS boot process.

The user can interact with BIOS setup, change and save settings as well as enter and interact with option ROM configuration screens.

At least two concurrent remote KVM sessions are supported. It is possible for at least two different users to connect to the same server and start remote KVM sessions.

7.1.6 Force-enter BIOS Setup

KVM redirection can present an option to force-enter BIOS Setup. This enables the system to enter F2 setup while booting which is often missed by the time the remote console redirects the video.

7.2 Media Redirection

The embedded web server provides a Java applet to enable remote media redirection. This may be used in conjunction with the remote KVM feature, or as a standalone applet.

The media redirection feature is intended to allow system administrators or users to mount a remote IDE or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the server.

Revision 2.0 73

Advanced Management Feature Support (RMM4)

Once mounted, the remote device appears just like a local device to the server, allowing system administrators or users to install software (including operating systems), copy files, update BIOS, and so on, or boot the server from this device.

The following capabilities are supported:

The operation of remotely mounted devices is independent of the local devices on the server. Both remote and local devices are useable in parallel.

Either IDE (CD-ROM, floppy) or USB devices can be mounted as a remote device to the server.

It is possible to boot all supported operating systems from the remotely mounted device and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See the

Tested/supported Operating System List for more information.

Media redirection supports redirection for both a virtual CD device and a virtual

Floppy/USB device concurrently. The CD device may be either a local CD drive or else an ISO image file; the Floppy/USB device may be a local Floppy drive, a local USB device, or a disk image file.

The media redirection feature supports multiple encryption algorithms, including RC4 and AES. The actual algorithm that is used is negotiated with the client based on the client’s capabilities.

A remote media session is maintained even when the server is powered-off (in standby mode). No restart of the remote media session is required during a server reset or power on/off. A BMC reset (for example, due to a BMC reset after BMC FW update) requires the session to be re-established

The mounted device is visible to (and useable by) managed system’s OS and BIOS in both pre-boot and post-boot states.

The mounted device shows up in the BIOS boot order and it is possible to change the

BIOS boot order to boot from this remote device.

It is possible to install an operating system on a bare metal server (no OS present) using the remotely mounted device. This may also require the use of KVM-r to configure the

OS during install.

USB storage devices appear as floppy disks over media redirection. This allows for the installation of device drivers during OS installation.

If either a virtual IDE or virtual floppy device is remotely attached during system boot, both the virtual IDE and virtual floppy are presented as bootable devices. It is not possible to present only a single-mounted device type to the system BIOS.

7.2.1 Availability

The default inactivity timeout is 30 minutes and is not user-configurable. Media redirection sessions persist across system reset but not across an AC power loss or BMC reset.

7.2.2 Network Port Usage

The KVM and media redirection features use the following ports:

5120

– CD Redirection

5123

– FD Redirection

74 Revision 2.0

5124

– CD Redirection (Secure)

5127

– FD Redirection (Secure)

7578

– Video Redirection

7582

– Video Redirection (Secure)

Advanced Management Feature Support (RMM4)

Revision 2.0 75

On-board Connector/Header Overview

8. On-board Connector/Header Overview

The following section provides detailed information regarding all connectors, headers, and jumpers on the server boards.

8.1 Board Connector Information

The following table lists all connector types available on the board and the corresponding preference designators printed on the silkscreen.

Table 25. Board Connector Matrix

Power supply

CPU

Connector

Main memory

PCI Express* x8 mechanical

PCI Express* x16 mechanical

Intel

®

RMM4 NIC

Intel

®

RMM4 Lite

SATA Key to enable ESRT2

RAID5

System fans

CPU fan

Battery

Stacked RJ45/2xUSB

VGA

Display Port

Serial port A

Serial port B

Front panel

Internal Dual USB 3.0

Internal Dual USB 2.0 eUSB SSD

Internal USB

HDD LED

2

1

1

1

1

1

1

1

1

1

1

4

1

1

3

1

1

1

3

Quantity

J9H1

J9B1

J9C3

Reference Designators

1

4

U6F1

J7C1, J8C1

J8C2, J9C2

J1B1, J2B1, J4B1

J3B1

J4C1

J4B1

1 J4A1

J3K4, J8K1, J8K2, J8B1

J7K1

BT2E1

JA5A1, JA6A1

J7A1

J8A1

J9A1

J9A2

J1E1

J1J1

J1K3

J5K1

J1J4

J1G2

Connector Type

Main power

CPU power

PS AUX

CPU sockets

DIMM sockets

Card edge

Card edge

Connector

Connector

Header

Header

Header

Battery holder

Dual USB/LAN

(RJ45) Combo

Connector

Connector

Connector

Connector

Header

Header

Header

Header

Header

Type-A USB

Header

Pin Count

24

8

5

1150

240

22

9

4

2

15

4

9

9

24

20

10

4

4

2

98

164

30

7

4

76 Revision 2.0

On-board Connector/Header Overview

SATA

Connector

HSBP_I2C

SATA SGPIO

LCP

IPMB

Configuration jumpers

TPM

Chassis Intrusion

I/O Module Connector

SAS Module Connector

1

1

1

1

1

1

1

1

6

Quantity Reference Designators

J1K4, J1K1, J1K5,

J1K2, J2K5, J2K3

5

J2K4

J2K2

Connector Type

Connector

Header

Header

J1G1

J2K1

Header

Header

J3K6 (Force Integrated BMC update),

J2K9 (Password Clear),

J2K8 (BIOS Recovery),

J2K6 (Reset BIOS Configuration)

J3K2 (ME Firmware Update)

Jumper

J8J1 Connector

J1F1

J1C1

J4J1

Header

Connector

Connector

8.2 Power Connectors

The main power supply connection uses an SSI-compliant 2x12 pin connector (J9H1).

7

4

3

5

Pin Count

7

3

14

2

80

80

Two additional power-related connectors also exist:

One SSI-compliant 2x4 pin power connector (J9B1) to provide 12-V power to the CPU voltage regulators and memory.

One SSI-compliant 1x5 pin connector (J9C3) to provide I2C monitoring of the power supply.

The following tables define these connector pin-outs:

Table 26. Main Power Connector Pin-out (J9H1)

6

7

8

9

10

11

12

3

4

5

1

Pin

2

Signal

+3.3 Vdc

+3.3 Vdc

GND

+5 Vdc

GND

Color Pin

Orange 13

Orange 14

Black

Red

Black

15

16

17

+5 Vdc

GND

Red

Black

PWR_OK Gray

5 VSB

+12 Vdc

+12 Vdc

+3.3 Vdc

Purple

Yellow

Yellow

Orange

18

19

20

21

22

23

24

Signal

+3.3 Vdc

-12 Vdc

GND

PS_ON#

GND

GND

GND

NC

+5 Vdc

+5 Vdc

+5 Vdc

GND

Black

Black

White

Red

Red

Red

Black

Color

Orange

Blue

Black

Green

Black

Revision 2.0 77

On-board Connector/Header Overview

Table 27. CPU Power Connector Pin-out (J9B1)

5

6

7

Pin

1

2

3

4

8

Signal

GND of Pin 5

GND of Pin 6

GND of Pin 7

GND of Pin 8

+12 Vdc CPU1

+12 Vdc CPU1

+12 Vdc

DDR3_CPU1

+12 Vdc

DDR3_CPU1

Black

Color

Black

Black

Black

Yellow/black

Yellow/black

Yellow/black

Yellow/black

Table 28. Power Supply Auxiliary Signal Connector Pin-out (J9C3)

Pin Signal

1 SMB_CLK_FP_PWR_R

2 SMB_DAT_FP_PWR_R

3 SMB_ALRT_3_ESB_R

4 3.3 V SENSE-

5 3.3 V SENSE+

Color

Orange

Black

Red

Yellow

Green

8.3 System Management Headers

8.3.1 Intel

®

A 30-pin Intel

®

RMM4 connector (J4C1) and a 7-pin Intel

®

RMM4 Lite connector (J4B1) are included on the server board to support the optional Intel

®

Remote Management Module 4 dedicated NIC module. This server board does not support third-party management cards.

Note: This connector is not compatible with the previous generation Intel

®

Remote Management

Modules (Intel

®

RMM/RMM2/RMM3)

13

15

17

19

21

23

1

Pin

3

5

7

9

11

Table 29. Intel

®

GND

GND

GND

GND

GND

GND

Signal Name

3V3_AUX

3V3_AUX

GND

GND

GND

GND

14

16

18

20

22

24

2

Pin

4

6

8

10

12

MDIO

MDC

TXD_0

TXD_1

TXD_2

TXD_3

TX_CTL

RX_CTL

RXD_0

RXD_1

RXD_2

RXD_3

Signal Name

78 Revision 2.0

On-board Connector/Header Overview

Pin

25

27

29

GND

GND

GND

Signal Name Pin

26

28

30

TX_CLK

RX_CLK

PRESENT#

Signal Name

Table 30. Intel

®

8.3.2

1

Pin

3

5

7

Signal Name

3V3_AUX

KEY PIN

SPI_RMM4_LITE_DO

SPI_RMM4_LITE_CS_N

TPM connector

2

Pin

4

6

8

Signal Name

SPI_RMM4_LITE_DI

SPI_RMM4_LITE_CLK

GND

GND

Table 31. TPM connector Pin-out (J8J1)

Pin

1

3

Signal Name

KEY PIN

LPC_LAD<0>

5

7

IRQ_SERIAL

P3V3

9 RST_IBMC_NIC_N

11 LPC_LAD<3>

13 GND

2

Pin

4

6

8

10

12

14

Signal Name

LPC_LAD<1>

GND

LPC_FRAME_N

GND

CLK_33M_TPM_CONN

GND

LPC_LAD<2>

8.3.3 Intel

®

The server board provides one connector to support Intel

®

ESRT2 RAID Upgrade Key. The I

Upgrade Key is a small PCB board that enables RAID 5 software stack of ESRT2 SW RAID.

The pin configuration of connector is identical and defined in the following table:

8.3.4

Table 32. Intel

®

1

Pin

2

3

4

Signal Name

GND

FM_PBG_DYN_SKU_KEY

GND

FM_SSB_SAS_SATA_RAID_KEY

Local Control Panel Header

Table 33. LCP Header Pin-out (J1G1)

Pin

1

2

3

4

5

Signal Name

SMB_SENSOR_3V3STBY_DATA

GND

SMB_SENSOR_3V3STBY_CLK

P3V3_AUX

FM_LCP_ENTER_N

Revision 2.0 79

On-board Connector/Header Overview

Pin

6

7

Signal Name

FM_LCP_LEFT_N

FM_LCP_RIGHT_N

8.3.5 HSBP_ I

2

C Header

Table 34. HSBP_ I

2

C Header Pin-out (J2K4)

1

Pin

2

3

Signal Name

SMB_HSBP_3V3STBY_DATA

GND

SMB_HSBP_3V3STBY_CLK

8.3.6 HDD LED Header

The server board includes a 2-pin hard drive activity LED header used with some SAS/SATA controller add-in cards. The header has the following pin-out.

Table 35. HDD LED Header Pin-out (J1G2)

1

Pin Signal Name

LED_HDD_ACT_N 2

Pin

N/A

Signal Name

8.3.7 Chassis Intrusion Header

The server board includes a 2-pin chassis intrusion header which can be used when the chassis is configured with a chassis intrusion switch. The header has the following pin-out.

Table 36. Chassis Intrusion Header Pin-out (J1F1)

Header State

Pins 1 and 2 closed

Pins 1 and 2 open

Description

FM_INTRUDER_HDR_N is pulled HIGH. Chassis cover is closed.

FM_INTRUDER_HDR_N is pulled LOW. Chassis cover is removed.

8.3.8 SATA SGPIO Header

SGPIO uses a 5pin header, this is to incorporate a ground conductor as an SI improvement over previous generation products and based on measurement data indicating add the ground is strongly recommended. The 5pin connector will be consistent with other HSBPs, in this way cable commonality is improved.

Table 37. SATA SGPIO Header Pin-out (J2K2)

1

Pin

2

3

4

5

Signal Name

SCLK

SLOAD

GND

SDATAOUT0

SDATAOUT1

80 Revision 2.0

On-board Connector/Header Overview

8.3.9 IPMB Connector

Table 38. IPMB Connector Pin-out (J2K1)

1

Pin

2

3

4

GND

P12V

FAN_PWM

FAN_TACH

Signal Name

8.4 Front Panel Connector

The server board provides a 24-pin front panel connector (J1E1) for use with Intel

®

and thirdparty chassis. The connector consists of a 24-pin SSI compatible front panel connector. The 24pin SSI front panel connector provides various front panel features including:

Power/Sleep Button

System ID Button

NMI Button

NIC Activity LEDs

Hard Drive Activity LEDs

System Status LED

System ID LED

The following table provides the pin-out for this connector:

Table 39. Front Panel 24-pin Connector Pin-out (J1E1)

15

17

19

21

23

1

3

5

7

9

11

13

Pin

SB3.3V

Key

Signal

Power LED Cathode

3.3V

HDD Activity LED Cathode

Power Switch

GND (Power Switch)

2

4

6

8

Pin

10

SB3.3V

Signal

SB5V

System ID LED Cathode

System Fault LED Anode

System Fault LED Cathode

12 NIC#1 (1/2) Activity LED

14 NIC#1 (1/2) Link LED

Reset Switch 16 I2C SDA

GND (Reset/ID/NMI Switch) 18 I2C SCL

System ID Switch

Pull Down

NMI to CPU Switch

20

22

24

Chassis Intrusion

NIC#2 Activity LED

NIC#2 Link LED

8.4.1 Power/Sleep Button and LED Support

Pressing the Power button will toggle the system power on and off. This button also functions as a sleep button if enabled by an ACPI compliant operating system. Pressing this button will send a signal to the integrated BMC, which will power on or power off the system. The power

LED is a single color and is capable of supporting different indicator states as defined in the following table.

Revision 2.0 81

On-board Connector/Header Overview

Table 40. Power/Sleep LED Functional States

State Power Mode

Power-off Non-ACPI

Power-on Non-ACPI

S5 ACPI

S4

S3-S1

ACPI

ACPI

Off

On

Off

Off

LED

Slow blink

Description

System power is off, and the BIOS has not initialized the chipset.

System power is on

Mechanical is off, and the operating system has not saved any context to the hard disk.

Mechanical is off. The operating system has saved context to the hard disk.

DC power is still on. The operating system has saved context and gone into a level of low-power state.

System and the operating system are up and running. S0 ACPI Steady on

8.4.2 System ID Button and LED Support

Pressing the System ID Button will toggle both the ID LED on the front panel and the Blue ID

LED on the server board on and off. The System ID LED is used to identify the system for maintenance when installed in a rack of similar server systems. The System ID LED can also be toggled on and off remotely using the IPMI Chassis Identify command which will cause the LED to blink for 15 seconds.

8.4.3 System Reset Button Support

When pressed, this button will reboot and re-initialize the system.

8.4.4 NMI Button Support

When the NMI button is pressed, it puts the server in a halt state and causes the BMC to issue a non-maskable interrupt (NMI). This can be useful when performing diagnostics for a given issue where a memory download is necessary to help determine the cause of the problem.

Once an NMI has been generated by the BMC, the BMC does not generate another NMI until the system has been reset or powered down.

The following actions cause the BMC to generate an NMI pulse:

Receiving a Chassis Control command to pulse the diagnostic interrupt. This command does not cause an event to be logged in the SEL.

Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action enabled.

The following table describes behavior regarding NMI signal generation and event logging by the BMC.

Table 41. NMI Signal Generation and Event Logging

Causal Event

Signal

Generation

X

NMI

Front Panel Diag Interrupt Sensor Event Logging

Support

Chassis Control command (pulse diagnostic interrupt)

Front panel diagnostic interrupt button pressed

Watchdog Timer pre-timeout expiration with

NMI/diagnostic interrupt action

X

X

X

X

82 Revision 2.0

On-board Connector/Header Overview

8.4.5 NIC Activity LED Support

The Front Control Panel includes an activity LED indicator for each on-board Network Interface

Controller (NIC). When a network link is detected, the LED will turn on solid. The LED will blink once network activity occurs at a rate that is consistent with the amount of network activity that is occurring.

8.4.6 Hard Drive Activity LED Support

The drive activity LED on the front panel indicates drive activity from the on-board hard disk controllers. The server board also provides a header giving access to this LED for add-in controllers.

8.4.7 System Status LED Support

The System Status LED is a bi-color (Green/Amber) indicator that shows the current health of the server system. The system provides two locations for this feature; one is located on the

Front Control Panel, the other is located on the back edge of the server board, viewable from the back of the system. Both LEDs are tied together and will show the same state. The System

Status LED states are driven by the on-board platform management sub-system.

8.5 I/O Connectors

8.5.1 VGA Connector

The following table details the pin-out definition of the VGA connector (J7A1).

Table 42. VGA Connector Pin-out (J7A1)

1

Pin

6

7

8

2

3

4

5

9

10

11

12

13

14

15

Signal Name

V_IO_R_CONN

V_IO_G_CONN

V_IO_B_CONN

TP_VID_CONN_B4

GND

GND

GND

GND

P5V

GND

TP_VID_CONN_B11

V_IO_DDCDAT

V_IO_HSYNC_CONN

V_IO_VSYNC_CONN

V_IO_DDCCLK

Description

Red (analog color signal R)

Green (analog color signal G)

Blue (analog color signal B)

No connection

Ground

Ground

Ground

Ground

+5V DC

Ground

No connection

DDCDAT

HSYNC (horizontal sync)

VSYNC (vertical sync)

DDCCLK

Revision 2.0 83

On-board Connector/Header Overview

8.5.2 Display Port Connector

The following table details the pin-out definition of the Display Port connector (J8A1).

Table 43. Display Port Connector Pin-out (J8A1)

7

8

9

10

11

12

13

4

5

6

1

Pin

2

3

14

15

16

17

18

19

20

Signal Name

OUT

GND

OUT

OUT

GND

OUT

GND

OUT

GND

OUT

OUT

GND

OUT

GND

I/O

GND

I/O

IN

PWR RTN

PWR OUT

Description

ML_LANE 0 (P)

Ground

ML_LANE 0 (N)

ML_LANE 1 (P)

Ground

ML_LANE 1 (N)

ML_LANE 2 (P)

Ground

ML_LANE 2 (N)

ML_LANE 3 (P)

Ground

ML_LANE 3 (N)

Ground

Ground

AUX_CH (P)

Ground

AUX_CH (N)

HOT PLUG DETECT

RETURN DP_PWR

DP_PWR

8.5.3 SATA Connectors

The server board provides up to 6 SATA connectors: SATA-0 (J1K4), SATA-1 (J1K1), SATA-2

(J1K5), SATA-3 (J1K2), SATA-4 (J2K5), and SATA-5 (J2K3).

The pin configuration for each connector is identical and defined in the following table:

Table 44. SATA Connector Pin-out (J1K4, J1K1, J1K5, J1K2, J2K5, J2K3)

4

5

6

7

1

Pin

2

3

GND

Signal Name

TXP

TXN

GND

RXN

RXP

GND

8.5.4 Serial Port Connectors

The server board provides one external DB9 Serial A port (J9A1) and one internal 9-pin Serial B header (J9A2). The following tables define the pin-outs.

84 Revision 2.0

On-board Connector/Header Overview

5

6

7

8

9

1

Pin

2

3

4

Table 45. External DB9 Serial A Port Pin-out (J9A1)

Signal Name

SPA_DCD

SPA_SIN_N

SPA_OUT_N

SPA_DTR

GND

SPA_DSR

SPA_RTS

SPA_CTS

SPA_RI

Description

DCD (carrier detect)

RXD (receive data)

TXD (Transmit data)

DTR (Data terminal ready)

Ground

DSR (data set ready)

RTS (request to send)

CTS (clear to send)

RI (Ring Indicate)

Table 46. Internal 9-pin Serial B Header Pin-out (J9A2)

4

5

6

7

Pin

1

2

3

Signal Name

SPB_DCD

SPB_DSR

SPB_SIN_N

SPB_RTS

SPB_OUT_N

SPB_CTS

SPB_DTR

8

9

SPB_RI

GND

10 KEY PIN

Description

DCD (carrier detect)

DSR (data set ready)

RXD (receive data)

RTS (request to send)

TXD (Transmit data)

CTS (clear to send)

DTR (Data terminal ready)

RI (Ring indicate)

Ground

No pin

8.5.5 USB Connector

One 2x5 connectors on the server board (J1K3) provides support for two additional USB 2.0 ports. J1K3 is recommended for front panel USB ports.

Table 47. Internal USB2.0 Connector Pin-out (J1K3)

4

5

6

Pin

1

2

3

Signal Name

USB_PWR_5V

USB_PWR_5V

USB _PN_CONN

USB _PN_CONN

USB _PP_CONN

USB _PP_CONN

7

8

GND

GND

9 KEY PIN

10 TP_USB _NC

Description

USB power

USB power

USB port negative signal

USB port negative signal

USB port positive signal

USB port positive signal

Ground

Ground

No pin

Test point

One 2x10 connectors on the server board (J1J1) provides support for two additional USB 3.0 ports. J1J1 is recommended for front panel USB ports.

Revision 2.0 85

On-board Connector/Header Overview

Table 48. Internal USB3.0 Connector Pin-out (J1J1)

6

7

8

9

10

Pin

1

2

3

4

5

15

16

17

18

11

12

13

14

19

20

Signal

Vbus

IntA_P1_SSRX-

IntA_P1_SSRX+

GND

IntA_P1_SSTX-

IntA_P1_SSTX+

GND

IntA_P1_D-

IntA_P1_D+

ID

IntA_P2_D+

IntA_P2_D-

GND

IntA_P2_SSTX+

IntA_P2_SSTX-

GND

IntA_P2_SSRX+

IntA_P2_SSRX-

Vbus

KEY PIN

Description

Power

USB3 ICC Port1 SuperSpeed Rx-

USB3 ICC Port1 SuperSpeed Rx+

Ground

USB3 ICC Port1 SuperSpeed Tx-

USB3 ICC Port1 SuperSpeed Tx+

Ground

USB3 ICC Port1 D- (USB2 Signal D-)

USB3 ICC Port1 D+ (USB2 Signal D+)

Over Current Protection

USB3 ICC Port2 D+ (USB2 Signal D+)

USB3 ICC Port2 D- (USB2 Signal D-)

Ground

USB3 ICC Port2 SuperSpeed Tx+

USB3 ICC Port2 Super Speed Tx-

Ground

USB3 ICC Port2 SuperSpeed Rx+

USB3 ICC Port2 SuperSpeed Rx-

Power

No pin

The server board includes one 10-pin 2mm low-profile connector (J5K1) on the server boards provides an option to support a low-profile eUSB Solid State Drive.

Table 49. Pin-out of Internal Low-Profile USB Connector (eUSB) for Solid State Drive (J5K1)

1

2

3

4

Pin

+5V

USB_N

Signal

USB_P

GND

6

7

8

9

Pin

NC

NC

NC

NC

Signal

5 Key Pin 10 LED#

The server board provides one additional Type A USB port (J1J4) to support the installation of a

USB device inside the server chassis.

Table 50. Internal Type A USB Port Pin-out (J1J4)

Pin

1

2

3

4

Signal Name

USB_PWR7_5V USB_PWR

USB_PN

USB _PP

GND

Description

USB port negative signal

USB port positive signal

Ground

86 Revision 2.0

On-board Connector/Header Overview

41

43

45

47

49

51

27

29

31

33

35

37

39

13

15

17

19

21

23

25

1

Pin

3

5

7

9

11

67

69

71

73

75

77

79

53

55

57

59

61

63

65

8.5.6 I/O Module Connector

The following table details the pin-out definition of the I/O Module connector (J1C1).

Table 51. I/O Module Connector Pin-out (J1C1)

Signal Name

P3V3

P3V3

P3V3

P3V3

RSVD_PIN9

GND

RSVD_PIN13

RSVD_PIN15

GND

RSVD_PIN19

14

16

18

20

RSVD_PIN21

GND

22

24

SMB_3V3SB_CLK 26

2

4

6

8

10

12

SMB_3V3SB_DAT 28

GND 30

PE_TN_7

PE_TP_7

32

34

GND

PE_TN_6

PE_TP_6

36

38

40

GND

PE_TN_5

PE_TP_5

GND

PE_TN_4

PE_TP_4

42

44

46

48

50

52

GND

PE_TN_3

PE_TP_3

GND

PE_TN_2

PE_TP_2

GND

PE_TN_1

PE_TP_1

GND

PE_TN_0

PE_TP_0

GND

RSVD_PIN79

68

70

72

74

76

78

80

54

56

58

60

62

64

66

Pin

PE_RP_4

GND

PE_RN_3

PE_RP_3

GND

PE_RN_2

PE_RP_2

GND

PE_RN_1

PE_RP_1

GND

PE_RN_0

PE_RP_0

GND

P12V

Signal Name

P12V

P12V

P12V

FRU_TEMP_ADDR

P5V_AUX

FM_IOM_EN

P3V3_AUX

LED _ACT_N

RPESENT_N

WAKE_N

RESET_N

GND

CLK_100M_DP

CLK_100M_DN

GND

PE_RN_7

PE_RP_7

GND

PE_RN_6

PE_RP_6

GND

PE_RN_5

PE_RP_5

GND

PE_RN_4

Revision 2.0 87

On-board Connector/Header Overview

41

43

45

47

49

51

27

29

31

33

35

37

39

13

15

17

19

21

23

25

1

Pin

3

5

7

9

11

67

69

71

73

75

77

79

53

55

57

59

61

63

65

8.5.7 SAS Module Connector

The following table details the pin-out definition of the SAS Module connector (J4J1).

Table 52. I/O Module Connector Pin-out (J4J1)

GND

PE_TP_3

PE_TN_3

GND

PE_TP_2

PE_TN_2

GND

PE_TP_1

PE_TN_1

GND

PE_TP_0

PE_TN_0

GND

Signal Name

RSVD_PIN1

GND

PE_TP_7

PE_TN_7

GND

PE_TP_6

PE_TN_6

GND

PE_TP_5

PE_TN_5

GND

PE_TP_4

PE_TN_4

SMD_3V3SB_DAT

SMD_3V3SB_CLK

GND

RSVD_PIN59

RSVD_PIN61

GND

RSVD_PIN65

RSVD_PIN67

GND

RSVD_PIN71

P3V3

P3V3

P3V3

P3V3

Pin

42

44

46

48

50

52

28

30

32

34

36

38

40

14

16

18

20

22

24

26

2

4

6

8

10

12

68

70

72

74

76

78

80

54

56

58

60

62

64

66

PE_RP_4

PE_RN_4

GND

PE_RP_3

PE_RN_3

GND

PE_RP_2

PE_RN_2

GND

PE_RP_1

PE_RN_1

GND

PE_RP_0

P12V

Signal Name

P12V

P12V

GND

PE_RP_7

PE_RN_7

GND

PE_RP_6

PE_RN_6

GND

PE_RP_5

PE_RN_5

GND

PE_RN_0

GND

RESET_N

WAKE_N

PRESENT_N

LED_ACT_N

P3V3_AUX

FM_SAS_EN

P5V_STBY

FRU_TEMP_ADDR

P12V

P12V

P12V

P12V

88 Revision 2.0

8.5.8 NIC1 with USB2.0 connector

Location: JA6A1

On-board Connector/Header Overview

Figure 18. NIC1 with USB2.0 connector

8.5.9 NIC2 with USB3.0 connector

Location: JA5A1

Revision 2.0

Figure 19. NIC2 with USB3.0 connector

89

On-board Connector/Header Overview

8.6 Fan Headers

The server board provides five SSI-compliant 4-pin fans (J7K1, J3K4, J8K1, J8K2 and J8B1) to use as CPU and I/O cooling fans. 3-pin fans are supported on all fan headers. The pin configuration for each of the 4-pin fan headers is identical and defined in the following tables.

1

Pin

2

3

4

One 4-pin fan header is designated as processor cooling fan:

- CPU fan (J7K1)

Three 4-pin fan headers are designated as system fans:

-

System fan 1 (J3K4)

- System fan 2 (J8K1)

-

System fan 3 (J8K2)

One 4-pin fan header is designated as a rear system fan:

-

System fan 4 (J8B1)

Table 53. SSI 4-pin Fan Header Pin-out (J7K1, J3K4, J8K1, J8K2, J8B1)

Signal Name

Ground

12V

Fan Tach Fan

PWM

Fan PWM Fan

Tach

Type

GND

Power Power supply 12 V

Description

Ground is the power supply ground

In Out

Out In

FAN_TACH signal is connected to the BMC to monitor the fan speed

FAN_PWM signal to control fan speed

FAN_PWM signal to control fan speed FAN_TACH signal is connected to the BMC to monitor the fan speed

Note: Intel Corporation server boards support peripheral components and can contain a number of highdensity VLSI and power delivery components that need adequate airflow to cool. Intel’s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together. It is the responsibility of the system integrator that chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.

90 Revision 2.0

BIOS Setup Interface

9. BIOS Setup Interface

9.1 HotKeys Supported During POST

Certain “HotKeys” are recognized during POST. A HotKey is a key or a key combination that is recognized as an unprompted command input, that is, the operator is not prompted to press the

HotKey and typically the HotKey will be recognized even while other processing is in progress.

The Intel

®

Server Board S1200V3RP Family BIOS recognizes a number of HotKeys during

POST. After the OS is booted, HotKeys are the responsibility of the OS and the OS defines its own set of recognized HotKeys.

Following are the POST HotKeys, with their functions:

Table 54. POST HotKeys Recognized

<F2>

<F6>

<F12>

<Esc>

<Pause>

HotKey Combination Function

Enter Setup

Pop up BIOS Boot Menu

Network boot

Switch from Logo Screen to Diagnostic Screen

Stop POST temporarily

9.2 POST Logo/Diagnostic Screen

The logo/Diagnostic Screen displays in one of two forms:

If Quiet Boot is enabled in the BIOS setup, a logo splash screen displays. By default,

Quiet Boot is enabled in the BIOS setup. If the logo displays during POST, press <Esc> to hide the logo and display the diagnostic screen.

If a logo is not present in the flash ROM or if Quiet Boot is disabled in the system configuration, the POST Diagnostic Screen is displayed with a summary of system configuration information.

The diagnostic screen displays the following information:

“Copyright <year> Intel Corporation”

AMI Copyright statement

BIOS version (ID)

BMC firmware version

SDR version

ME firmware version

Platform ID

System memory detected (total size of all installed DDRIII DIMMs)

Current memory speed (currently configured memory operating frequency)

Processor information (Intel

®

Brand String identifying type of processor and nominal operating frequency, and number of physical processors identified).

Keyboards detected, if any attached

Revision 2.0 91

BIOS Setup Interface

Mouse devices detected, if any attached

Instructions showing HotKeys for going to Setup, going to popup Boot Menu, starting

Network Boot

9.3 BIOS Boot Pop-up Menu

The BIOS Boot Specification (BBS) provides a Boot Pop-up menu that can be invoked by pressing the <F6> key during POST. The BBS Pop-up menu displays all available boot devices.

The boot order in the pop-up menu is not the same as the boot order in the BIOS setup. The pop-up menu simply lists all of the available devices from which the system can be booted, and allows a manual selection of the desired boot device.

When an Administrator password is installed in Setup, the Administrator password will be required in order to access the Boot Pop-up menu using the <F6> key. If a User password is entered, the Boot Pop-up menu will not even appear

– the user will be taken directly to the Boot

Manager in the Setup, where the User password allows only booting in the order previously defined by the Administrator.

9.4 BIOS Setup Utility

The BIOS Setup utility is a text-based utility that allows the user to configure the system and view current settings and environment information for the platform devices. The Setup utility controls the platform's built-in devices, the boot manager, and error manager.

The BIOS Setup interface consists of a number of pages or screens. Each page contains information or links to other pages. The advanced tab in Setup displays a list of general categori es as links. These links lead to pages containing a specific category’s configuration.

The following sections describe the look and behavior for the platform setup.

9.4.1 BIOS Setup Operation

The BIOS Setup Utility has the following features:

Localization

– The Intel

®

Server Board BIOS is only available in English. However, BIOS

Setup uses the Unicode standard and is capable of displaying data and input in Setup fields in all languages currently included in the Unicode standard.

Console Redirection

– BIOS Setup is functional through Console Redirection over various terminal emulation standards. This may limit some functionality for compatibility, for example, usage of colors or some keys or key sequences or support of pointing devices.

Setup screens are designed to be displayable in an 80-character x 24-line format in order to work with Console Redirection, although that screen layout should display correctly on any format with longer lines or more lines on the screen.

Password protection

– BIOS Setup may be protected from unauthorized changes by setting an Administrative Password in the Security screen. When an Administrative

Password has been set, all selection and data entry fields in Setup (except System Time and Date) are grayed out and cannot be changed unless the Administrative Password has been entered.

92 Revision 2.0

BIOS Setup Interface

Note: If an Administrative Password has not been set, anyone who boots the system to Setup has access to all selection and data entry fields in Setup and can change any of them.

9.4.1.1 Setup Page Layout

The Setup page layout is sectioned into functional areas. Each occupies a specific area of the screen and has dedicated functionality. The following table lists and describes each functional area.

The Setup page is designed to a format of 80 x 24 (24 lines of 80 characters each). The typical display screen in a Legacy mode or in a terminal emulator mode is actually 80 characters by 25 lines, but with “line wrap” enabled (which it usually is) the 25th line cannot be used with the

Setup page.

Table 55. BIOS Setup Page Layout

Functional Area

Title (Tab) Bar

Page Title

Setup Item List

Item-Specific Help Area

Keyboard Command Area

Description

The Title Bar is located at the top of the screen and displays “Tabs” with the titles of the top-level pages, or screens, that can be selected. Using the left and right arrow keys moves from page to page through the Tabs.

When there are more Tabs than can be displayed on the Title (Tab) Bar, they will scroll off to the left or right of the screen and temporarily disappear from the visible Title Bar. Using the arrow keys will scroll them back onto the visible Title Bar. When the arrow keys reach either end of the Title Bar, they will “wrap around” to the other end of the Title Bar.

For multi-level hierarchies, this shows only the top-level page above the page which the user is currently viewing. The Page Title gives further information.

In a multi-level hierarchy of pages beneath one of the top-level Tabs, the

Page Title identifying the specific page which the user is viewing is located in the upper left corner of the page. Using the <ESC> (Escape) key will return the user to the higher level in the hierarchy, until the top-level Tab page is reached.

The Setup Item List is a set of control entries and informational items. The list is displayed in two columns. For each item in the list:

 The left column of the list contains Prompt String (or Label String), a character string which identifies the item. The Prompt String may be up to 34 characters long in the 80 x 24 page format.

 The right column contains a data field which may be an informational data display, a data input field, or a multiple choice field. Data input or multiplechoice fields are demarcated by square brackets “[....]”. This field may be up to 90 characters long but only the first 22 characters can be displayed on the 80 x 24 page (24 characters for an informational display-only field).

The operator navigates up and down the right hand column through the available input or choice fields.

A Setup Item may also represent a selection to open a new screen with a further group of options for specific functionality. In this case, the operator navigates to the desired selection and presses <Enter> to go to the new screen.

The Item-specific Help Area is located on the right side of the screen and contains Help Text specific to the highlighted Setup Item. Help information may include the meaning and usage of the item, allowable values, effects of the options, etc.

The Help Area is a 29 character by 11 line section of the 80 x 24 page. The

Help Text may have explicit line-breaks within it. When the text is longer

Revision 2.0 93

BIOS Setup Interface

Functional Area Description than 29 characters, it is also broken to a new line, dividing the text at the last space (blank) character before the 29th character. An unbroken string of more than 29 characters will be arbitrarily wrapped to a new line after the

29th character. Text that extends beyond the end of the 11th line will not be displayed.

9.4.1.2 Entering BIOS Setup

To enter the BIOS Setup using a keyboard (or emulated keyboard), press the <F2> function key during boot time when the OEM or Intel logo is displayed. The following message is displayed on the diagnostics screen and under the Quiet Boot logo screen:

Press <F2> to enter setup

When the Setup Utility is entered, the Main screen is displayed. However, serious errors cause the system to display the Error Manager screen instead of the Main screen.

It is also possible to cause a boot to Setup using an IPMI 2.0 command “Get/Set System Boot

Options”. For details on that capability, see the explanation in the IPMI description.

9.4.1.3 Setup Navigation Keyboard Commands

The bottom right portion of the Setup screen provides a list of commands that are used to navigate through the Setup utility. These commands are displayed at all times.

Each Setup menu page contains a number of features. Each feature is associated with a value field, except those used for informative purposes. Each value field contains configurable parameters. Depending on the security option chosen and in effect by the password, a menu fe ature’s value may or may not be changed. If a value cannot be changed, its field is made inaccessible and appears grayed out.

Table 56. BIOS Setup: Keyboard Command Bar

Key

<Enter>

<Esc>

Option

Execute

Command

Exit

Select Item

Select Item

Description

The <Enter> key is used to activate submenus when the selected feature is a submenu, or to display a pick list if a selected option has a value field, or to select a subfield for multi-valued features like time and date. If a pick list is displayed, the <Enter> key selects the currently highlighted item, undoes the pick list, and returns the focus to the parent menu.

The <Esc> key provides a mechanism for backing out of any field. When the <Esc> key is pressed while editing any field or selecting features of a menu, the parent menu is re-entered.

When the <Esc> key is pressed in any submenu, the parent menu is reentered. When the <Esc> key is pressed in any major menu, the exit confirmation window is displayed and the user is asked whether changes can be discarded. If “No” is selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user is returned to where they were before

<Esc> was pressed, without affecting any existing settings. If “Yes” is selected and the <Enter> key is pressed, the setup is exited and the BIOS returns to the main System Options Menu screen.

The up arrow is used to select the previous value in a pick list, or the previous option in a menu item's option list. The selected item must then be activated by pressing the <Enter> key.

94 Revision 2.0

BIOS Setup Interface

<Tab>

-

+

<F9>

<F10>

Key Option

Select Menu

Select Field

Change Value

Change Value

Setup Defaults

Save and Exit

Description

The down arrow is used to select the next value in a menu item’s option list, or a value field’s pick list. The selected item must then be activated by pressing the <Enter> key.

The left and right arrow keys are used to move between the major menu pages. The keys have no effect if a sub-menu or pick list is displayed.

The <Tab> key is used to move between fields. For example, <Tab> can be used to move from hours to minutes in the time item in the main menu.

The minus key on the keypad is used to change the value of the current item to the previous value. This key scrolls through the values in the associated pick list without displaying the full list.

Pressing the <F9> key causes the following to display:

Load Optimized Defaults?

Yes No

If “Yes” is highlighted and <Enter> is pressed, all Setup fields are set to their default values. If “No” is highlighted and <Enter> is pressed, or if the

<Esc> key is pressed, the user is returned to where they were before <F9> was pressed without affecting any existing field values.

Pressing the <F10> key causes the following message to display:

Save configuration and reset?

Yes No

If “Yes” is highlighted and <Enter> is pressed, all changes are saved and the Setup is exited. If “No” is highlighted and <Enter> is pressed, or the

<Esc> key is pressed, the user is returned to where they were before

<F10> was pressed without affecting any existing values.

9.4.1.4 Setup Screen Menu Selection Bar

The Setup Screen Menu selection bar is located at the top of the BIOS Setup Utility screen. It displays tabs showing the major screen selections available to the user. By using the left and right arrow keys, the user can select the listed screens. Some screen selections are out of the visible menu space, and become available by scrolling to the left or right of the current selections displayed.

9.4.2 BIOS Setup Utility Screens

The following sections describe the screens available in the BIOS Setup utility for the configuration of the server platform.

For each of these screens, there is an image of the screen with a list of Field Descriptions which describe the contents of each item on the screen. Each item on the screen is hyperlinked to the relevant Field Description. Each Field Description is hyperlinked back to the screen image.

These lists follow the following guidelines:

The text heading for each Field Description is the actual text as displayed on the BIOS

Setup screen. This screen text is a hyperlink to its corresponding Field Description.

The text shown in the Option Values and Help Text entries in each Field Description are the actual text and values are displayed on the BIOS Setup screens.

Revision 2.0 95

BIOS Setup Interface

In the Option Values entry, the text for default values is shown with an underline. These values do not appear underline on the BIOS Setup screen. The underlined text in this document is to serve as a reference to which value is the default value.

The Help Text entry is the actual text which appears on the screen to accompany the item when the item is the one in focus (active on the screen).

The Comments entry provides additional information where it may be helpful. This information does not appear on the BIOS Setup screens.

Information enclosed in angular brackets (< >) in the screen shots identifies text that can vary, depending on the option(s) installed. For example, <Amount of memory installed> is replaced by the actual value for “Total Memory”.

Information enclosed in square brackets ([ ]) in the tables identifies areas where the user must type in text instead of selecting from a provided option.

9.4.2.1

Whenever information is changed (except Date and Time), the systems requires a save and reboot to take place in order for the changes to take effect. Alternatively, pressing

<ESC> discards the changes and resumes POST to continue to boot the system according to the boot order set from the last boot.

Map of Screens and Functionality

There are a number of screens in the entire Setup collection. They are organized into major categories. Each category has a hierarchy beginning with a top-level screen from which lowerlevel screens may be selected. Each top-level screen appears as a tab, arranged across the top of the Setup screen image of all top-level screens.

There are more categories than will fit across the top of the screen, so at any given time there will be some categories which will not appear until the user has scrolled across the tabs which are present.

The categories and the screens included in each category are listed as follows, with links to each of the screens named:

Table 57. Screen Map

Categories (Top Tabs)

Main Screen (Tab)

Advanced Screen (Tab)

2nd Level Screens

Processor Configuration

Memory Configuration

Mass Storage Controller

Configuration

PCI Configuration

Serial Port Configuration

USB Configuration

System Acoustic and Performance

Configuration

Network Stack

3rd Level Screens

NIC Configuration

96 Revision 2.0

BIOS Setup Interface

Categories (Top Tabs)

Security Screen (Tab)

Server Management Screen (Tab)

Boot Options Screen (Tab)

Boot Manager Screen (Tab)

Error Manager Screen (Tab)

Save & Exit Screen (Tab)

2nd Level Screens

Console Redirection

System Information

BMC LAN Configuration

CDROM Order

Hard Disk Order

Floppy Order

Network Device Order

BEV Device Order

Add EFI Boot Option

Delete EFI Boot Option

3rd Level Screens

9.4.2.2 Main Screen (Tab)

The Main Screen is the first screen that appears when the BIOS Setup configuration utility is entered, unless an error has occurred. If an error has occurred, the Error Manager Screen appears instead.

Revision 2.0

Figure 20. Main Screen

97

BIOS Setup Interface

Screen Field Descriptions:

1. Logged in as:

Option Values:

Help Text:

<Administrator / User>

<None>

Comments: Information only. Displays password level that setup is running in:

Administrator or User. With no passwords set, Administrator is the default mode.

Back to [Main Screen]

— [Screen Map]

2. Platform ID

Option Values: < Platform ID>

<None> Help Text:

Comments: Information only. Displays the Platform ID (Board ID) for the board on which the BIOS is executing POST.

The Platform ID is limited to 8 characters, because it is also used in the ACPI Tables which have that limitation. In some cases, this means that the Platform ID is abbreviated from the marketing designation.

Back to [Main Screen]

— [Screen Map]

3. System Booted From

Option Values:

Help Text:

< Primary/Backup>

<None>

Comments: Information only. Displays the exact BIOS portion on the board which is executing POST.

Boot from Backup BIOS means the BIOS is running in Recovery mode and the Primary

BIOS may be corrupted.

Back to [Main Screen]

— [Screen Map]

4. Primary BIOS Version

Option Values:

Help Text:

<Current Primary BIOS version ID>

<None>

Comments: Information only. The primary BIOS version displayed uniquely identifies the primary BIOS currently installed and operational on the board. The version information displayed is taken from the BIOS ID String, with the timestamp segment dropped off. The segments displayed are:

98 Revision 2.0

BIOS Setup Interface

Platform:

86B: xx: yy:

Identifies that this is the correct platform BIOS

Identifies this BIOS as being an Intel Server BIOS

Major Revision level of the BIOS

Release Revision level for this BIOS zzzz: Release Number for this BIOS

Back to [Main Screen]

— [Screen Map]

5. Backup BIOS Version

Option Values:

Help Text:

<Current Backup BIOS version ID>

<None>

Comments: Information only. The Backup BIOS version displayed uniquely identifies the backup BIOS that is currently installed and operational on the board. The version information displayed is taken from the BIOS ID String, with the timestamp segment dropped off. The segments displayed are:

Platform:

86B: xx: yy:

Identifies that this is the correct platform BIOS

Identifies this BIOS as being an Intel Server BIOS

Major Revision level of the BIOS

Release Revision level for this BIOS zzzz: Release Number for this BIOS

Back to [Main Screen]

— [Screen Map]

6. Build Date

Option Values:

created (built)>

Help Text:

<Date and time when the currently installed BIOS was

<None>

Comments: Information only. The time and date displayed are taken from the timestamp segment of the BIOS ID String.

Back to [Main Screen]

— [Screen Map]

7. Total Memory

Option Values:

Help Text:

<Amount of memory installed in the system>

<None>

Revision 2.0 99

BIOS Setup Interface

Comments: Information only. Displays the total physical memory installed in the system, in MB or GB. The term physical memory indicates the total memory discovered in the form of installed DDR3 DIMMs.

Back to [Main Screen]

— [Screen Map]

8. Quiet Boot

Option Values: Enabled

Disabled

Help Text:

[Enabled]

– Display the logo screen during POST.

[Disabled]

– Display the diagnostic screen during POST.

Comments: This field controls whether the full diagnostic information is displayed on the screen during POST. When Console Redirection is enabled, the Quiet

Boot setting is disregarded and the text mode Diagnostic Screen is displayed unconditionally.

Back to [Main Screen]

— [Screen Map]

9. POST Error Pause

Option Values: Enabled

Disabled

Help Text:

[Enabled]

– Go to the Error Manager for critical POST errors.

[Disabled]

– Attempt to boot and do not go to the Error Manager for critical POST errors.

Comments: If enabled, the POST Error Pause option takes the system to the error manager to review the errors when major errors occur. Minor and fatal error displays are not affected by this setting.

Back to [Main Screen]

— [Screen Map]

10. System Date

Option Values:

<System Date initially displays the current system calendar

date, including the day of the week>

Help Text:

System Date has configurable fields for the current Month, Day, and Year.

100 Revision 2.0

BIOS Setup Interface

The year must be between 2005 and 2099.

Use [Enter] or [Tab] key to select the next field.

Use [+] or [-] key to modify the selected field.

Comments: This field will initially display the current system day of week and date. It may be edited to change the system date. When the System Date is reset by the

“BIOS Defaults” jumper, BIOS Recovery Flash Update, or other method, the date will be the earliest date in the allowed range

– Saturday 01/01/2005.

Back to [Main Screen]

— [Screen Map]

11. System Time

Option Values:

day, in 24-hour format>

<System Time initially displays the current system time of

Help Text:

System Time has configurable fields for Hours, Minutes, and Seconds.

Hours are in 24-hour format.

Use the [Enter] or [Tab] key to select the next field.

Use the [+] or [-] key to modify the selected field.

Comments: This field will initially display the current system time (24 hour time). It may be edited to change the system time. When the System Time is reset by the “BIOS Defaults” jumper, BIOS Recovery Flash Update, or other method, the time will be the earliest time of day in the allowed range

– 00:00:00 (although the time will be updated beginning from when it is reset early in POST).

Back to [Main Screen]

— [Screen Map]

9.4.2.3 Advanced Screen (Tab)

The Advanced screen provides an access point to configure several groups of options. On this screen, the user can select the option group to be configured. Configuration actions are performed on the selected screen, and not directly on the Advanced screen.

This screen is the same for all board series, selecting between the same groups of options, although the options for different boards are not necessarily identical.

To access this screen from the Main screen or other toplevel “Tab” screen, press the right or left arrow keys to traverse the tabs at the top of the Setup screen until the Advanced screen is selected.

Revision 2.0 101

BIOS Setup Interface

Figure 21. Advanced Screen

Screen Field Descriptions:

1. Processor Configuration

Option Values:

Help Text:

<None>

View/Configure processor information and settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the Processor Configuration group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

2. Memory Configuration

Option Values:

Help Text:

<None>

View/Configure memory information and settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the Memory Configuration group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

3. Mass Storage Controller Configuration

Option Values: <None>

Help Text:

View/Configure mass storage controller information and settings.

102 Revision 2.0

BIOS Setup Interface

Comments: Selection only. Select this line and press the <Enter> key to go to the Mass Storage Controller Configuration group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

4. PCI Configuration

Option Values: <None>

Help Text:

View/Configure PCI information and settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the PCI Configuration group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

5. Serial Port Configuration

Option Values: <None>

Help Text:

View/Configure serial port information and settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the Serial Port Configuration group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

6. USB Configuration

Option Values: <None>

Help Text:

View/Configure USB information and settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the USB Configuration group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

7. System Acoustic and Performance Configuration

Option Values: <None>

Help Text:

View/Configure system acoustic and performance information and settings.

Revision 2.0 103

BIOS Setup Interface

Comments: Selection only. Select this line and press the <Enter> key to go to the System Acoustic and Performance Configuration group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

8. Network Stack

Option Values:

Help Text:

Network Stack Settings.

<None>

Comments: Selection only. Select this line and press the <Enter> key to go to the Network Stack group of configuration settings.

Back to [Advanced Screen]

— [Screen Map]

9.4.2.4 Processor Configuration

The Processor Configuration screen displays the processor identification and microcode level, core frequency, cache sizes information for all processors currently installed. It also allows the user to enable or disable a number of processor options.

To access this screen from the Main screen, select Advanced > Processor Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen, then select the desired screen.

The Processor Configuration screen will display different fields for single-socket, 2- socket and

4-socket boards shown as below Figures.

104 Revision 2.0

BIOS Setup Interface

Figure 22. Processor Configuration Screen

Screen Field Descriptions:

1. Processor ID

Option Values:

Help Text:

<CPUID>

<None>

Comments: Information only. Displays the Processor Signature value (from the

CPUID instruction) identifying the type of processor and the stepping. S1200V3RP series boards have a single Processor ID display.

Revision 2.0 105

BIOS Setup Interface

Back to [Advanced Screen]

— [Screen Map]

2. Processor Frequency

Option Values:

Help Text:

<Current Processor Operating Frequency>

<None>

Comments: processor.

Information only. Displays current operating frequency of the

Back to [Advanced Screen]

— [Screen Map]

3. Microcode Revision

Option Values:

Help Text:

<Microcode Revision Number>

<None>

Comments: processor microcode.

Information only. Displays Revision Level of the currently loaded

Back to [Advanced Screen]

— [Screen Map]

4. L1 Cache RAM

Option Values: <L1 cache size>

<None> Help Text:

Comments: Information only. Displays size in KB of the processor L1 Cache.

Since L1 cache is not shared between cores, this is shown as the amount of L1 cache per core. There are two types of L1 cache, so this amount is the total of L1 Instruction

Cache plus L1 Data Cache for each core.

Back to [Advanced Screen]

— [Screen Map]

5. L2 Cache RAM

Option Values: <L2 cache size>

<None> Help Text:

Comments: Information only. Displays size in KB of the processor L2 Cache.

Since L2 cache is not shared between cores, this is shown as the amount of L2 cache per core.

Back to [Advanced Screen]

— [Screen Map]

6. L3 Cache RAM

Option Values: <L3 cache size>

106 Revision 2.0

BIOS Setup Interface

Help Text: <None>

Comments: Information only. Displays size in MB of the processor L3 Cache.

Since L3 cache is shared between all cores in a processor package, this is shown as the total amount of L3 cache per processor package.

Back to [Advanced Screen]

— [Screen Map]

7. Processor Version

Option Values: <ID string from processor>

<None> Help Text:

Comments: Information only. Displays Brand ID string read from processor with CPUID instruction.

Back to [Advanced Screen]

— [Screen Map]

8. CPU Core Ratio

Option Values: [0

– 63]

Help Text:

Enter Core Ratio Multiplier. 0 - 63.

Comments: be Enabled.

In order for this option to be available, Show CPU Core Ratio must

Back to [Advanced Screen]

— [Screen Map]

9. Show CPU Core Ratio

Option Values:

Help Text:

Enabled

Disabled

Allow Edits to Core Ratio Multiplier.

Comments:

Back to [Advanced Screen]

— [Screen Map]

10. Intel(R) Turbo Boost Technology

Option Values: Enabled

Disabled

Revision 2.0 107

BIOS Setup Interface

Help Text:

Intel(R) Turbo Boost Technology allows the processor to automatically increase its

frequency if it is running below power, temperature, and current specifications.

Comments: This option is only visible if all processors installed in the system support Intel

®

Turbo Boost Technology. In order for this option to be available, Enhanced

Intel

®

SpeedStep

®

Technology must be Enabled.

Back to [Advanced Screen]

— [Screen Map]

11. Enhanced Intel SpeedStep(R) Tech

Option Values: Enabled

Disabled

Help Text:

Enhanced Intel SpeedStep (R) Technology allows the system to dynamically adjust processor voltage and core frequency, which can result in decreased average power consumption and decreased average heat production.

Contact your OS vendor regarding OS support of this feature.

Comments: When Disabled, the processor setting reverts to running at Max

TDP Core Frequency (rated frequency).

This option is only visible if all processors installed in the system support Enhanced

Intel

®

SpeedStep

®

Technology. In order for the Intel

®

Turbo Boost option to be available,

Enhanced Intel

®

SpeedStep

®

Technology must be Enabled.

Back to [Advanced Screen]

— [Screen Map]

12. Processor C3

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Processor C3 (ACPI C2/C3) report to OS

Comments: This is normally Disabled but can be Enabled for improved performance on certain benchmarks and in certain situations.

Back to [Advanced Screen]

— [Screen Map]

13. Processor C6

Option Values: Enabled

108 Revision 2.0

BIOS Setup Interface

Help Text:

Disabled

Enable/Disable Processor C6 (ACPI C3) report to OS

Comments: This is normally Enabled but can be Disabled for improved performance on certain benchmarks and in certain situations.

Back to [Advanced Screen]

— [Screen Map]

14. Intel(R) Hyper-Threading Tech

Option Values: Enabled

Disabled

Help Text:

Intel (R) Hyper-Threading Technology allows multithreaded software applications to

execute threads in parallel within each processor.

Contact your OS vendor regarding OS support of this feature.

Comments: This option is only visible if all processors installed in the system support Intel® Hyper-Threading Technology.

Back to [Advanced Screen]

— [Screen Map]

15. Active Processor Cores

Option Values: All

1

2

3

4

5

6

7

Help Text:

Number of cores to enable in each processor package.

Revision 2.0 109

BIOS Setup Interface

Comments: The numbers of cores that appear as selections depends on the number of cores available in the processors installed. Boards may have as many as 8 cores in each of 1, 2, or 4 processors. The same number of cores must be active in each processor package.

This Setup screen should begin with the number of currently-active cores as the number displayed. See note below

– this may be different from the number previously set by the user.

Note: The ME can control the number of active cores independently of the BIOS Setup setting. If the ME disables or enables processor cores, that will override the BIOS setting, and the number selected by BIOS will be disregarded.

Back to [Advanced Screen]

— [Screen Map]

16. Execute Disable Bit

Option Values: Enabled

Disabled

Help Text:

Execute Disable Bit can help prevent certain classes of malicious buffer overflow attacks.

Contact your OS vendor regarding OS support of this feature.

Comments: This option is only visible if all processors installed in the system support the Execute Disable Bit. The OS and applications installed must support this feature in order for it to be enabled.

Back to [Advanced Screen]

— [Screen Map]

17. Intel (R) Virtualization Technology

Option Values: Enabled

Disabled

Help Text:

Intel (R) Virtualization Technology allows a platform to run multiple operating systems and applications in independent partitions.

Note: A change to this option requires the system to be powered off and then back on before the setting takes effect.

Comments: This option is only visible if all processors installed in the system support Intel® VT. The software configuration installed on the system must support this feature in order for it to be enabled.

110 Revision 2.0

BIOS Setup Interface

Back to [Advanced Screen]

— [Screen Map]

18. Intel(R) VT for Directed I/O

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Intel (R) Virtualization Technology for Directed I/O (Intel (R) VT-d).

Report the I/O device assignment to VMM through DMAR ACPI Tables.

Comments: This option is only visible if all processors installed in the system support Intel® VT-d. The software configuration installed on the system must support this feature in order for it to be enabled.

Back to [Advanced Screen]

— [Screen Map]

19. Interrupt Remapping

Option Values:

Help Text:

Enabled

Disabled

Enable/Disable Intel (R) VT-d Interrupt Remapping support. For some processors, this option may be "always enabled".

Comments: This option only appears when Intel

®

Virtualization Technology for

Directed I/O is Enabled. For some processors this will be enabled unconditionally whenever Intel

®

VT-d is enabled. In that case, this option will be shown as "Enabled", and grayed out and not changeable.

Back to [Advanced Screen]

— [Screen Map]

20. Pass-through DMA Support

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Intel (R) VT-d Pass-through DMA support. For some processors, this option may be "always enabled".

Comments: This option only appears when Intel

®

Virtualization Technology for

Directed I/O is Enabled. For some processors this will be enabled unconditionally

Revision 2.0 111

BIOS Setup Interface whenever Intel® VT-d is enabled. In that case, this option will be shown as "Enabled", and grayed out and not changeable.

Back to [Advanced Screen]

— [Screen Map]

21. Intel(R) TXT

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Intel(R) Trusted Execution Technology. Takes effect after reboot.

Comments: Intel

®

TXT only appears when both Intel

®

Virtualization

Technology and Intel

®

VT for Directed IO are enabled.

This option appears only on models equipped with a TPM Module. The TPM Module must be active in order to support Intel

®

TXT.

Note: Changing the setting for Intel

®

TXT will require the system to perform a Hard Reset in order for the new setting to become effective.

Back to [Advanced Screen]

— [Screen Map]

22. Enhanced Error Containment Mode

Option Values: Enabled

Disabled

Help Text:

Enable Enhanced Error Containment Mode (Data Poisoning) - Erroneous data coming from memory will be poisoned. If Disabled (default), will be in Legacy Mode - No data poisoning support available.

Comments: Enhanced Error Containment (Data Poisoning) is not supported by all models of processors, and this option will not appear unless all installed processors support Enhanced Error Containment. This option globally enables or disables both Core and Uncore Data Poisoning, for processors which support them.

Back to [Advanced Screen]

— [Screen Map]

23. MLC Streamer

Option Values:

Help Text:

Enabled

Disabled

112 Revision 2.0

BIOS Setup Interface

MLC Streamer is a speculative prefetch unit within the processor(s).

Note: Modifying this setting may affect performance.

Comments: MLC Streamer is normally Enabled, for best efficiency in L2

Cache and Memory Channel use but disabling it may improve performance for some processing loads and on certain benchmarks.

Back to [Advanced Screen]

— [Screen Map]

24. MLC Spatial Prefetcher

Option Values: Enabled

Disabled

Help Text:

[Enabled]

– Fetches adjacent cache line (128 bytes) when required data is not currently in cache.

[Disabled]

– Only fetches cache line with data required by the processor (64 bytes).

Comments: MLC Spatial Prefetcher is normally Enabled, for best efficiency in

L2 Cache and Memory Channel use but disabling it may improve performance for some processing loads and on certain benchmarks.

Back to [Advanced Screen]

— [Screen Map]

25. DCU Data Prefetcher

Option Values: Enabled

Help Text:

Disabled

The next cache line will be prefetched into L1 data cache from L2 or system memory during unused cycles if it sees that the processor core has accessed several bytes sequentially in a cache line as data.

[Disabled]

– Only fetches cache line with data required by the processor (64 bytes).

Comments: DCU Data Prefetcher is normally Enabled, for best efficiency in L1

Data Cache and Memory Channel use but disabling it may improve performance for some processing loads and on certain benchmarks.

Back to [Advanced Screen]

— [Screen Map]

26. DCU Instruction Prefetcher

Option Values: Enabled

Revision 2.0 113

BIOS Setup Interface

Help Text:

Disabled

The next cache line will be prefetched into L1 instruction cache from L2 or system memory during unused cycles if it sees that the processor core has accessed several bytes sequentially in a cache line as data.

Comments: DCU Data Prefetcher is normally Enabled, for best efficiency in L1

Instruction Cache and Memory Channel use but disabling it may improve performance for some processing loads and on certain benchmarks.

Back to [Advanced Screen]

— [Screen Map]

27. Intel (SMX) Safer Mode Extensions

Option Values: Enabled

Disabled

Help Text:

When Enabled, a SMX can utilize the additional hardware capabilities provided by Safer

Mode Extensions.

Comments:

Back to [Advanced Screen]

— [Screen Map]

28. SMM Wait Timeout

Option Values:

[Entry Field 20

– 3000ms, 20 is default]

Help Text:

Millisecond timeout waiting for BSP and APs to enter SMM. Range is 20ms to 3000ms.

Comments: Amount of time to allow for the SMI Handler to respond to an SMI.

If exceeded, BMC generates an SMI Timeout and resets the system.

Note: this field is temporary, and will be removed when no longer required.

Back to [Advanced Screen]

— [Screen Map]

9.4.2.5 Memory Configuration

The Memory Configuration screen allows the user to view details about the DDR3 DIMMs that are installed as system memory, and alter BIOS Memory Configuration settings where appropriate.

114 Revision 2.0

BIOS Setup Interface

To access this screen from the Main screen, select Advanced > Memory Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen, then select the desired screen.

Figure 23. Memory Configuration Screen

Screen Field Descriptions:

1. Total Memory

Option Values:

Help Text:

<Total Physical Memory Installed in System>

<None>

Comments: Information only. Displays the amount of memory available in the system in the form of installed DDR3 DIMMs, in units of GB.

Back to [Memory Configuration Screen]

— [Advanced Screen] — [Screen Map]

2. Effective Memory

Option Values:

Help Text:

<Total Effective Memory>

<None>

Revision 2.0 115

BIOS Setup Interface

Comments:

OS in MB or GB.

Information only. Displays the amount of memory available to the

The Effective Memory is the Total Physical Memory minus the sum of all memory reserved for internal usage, RAS redundancy and SMRAM.

Note: some server operating systems do not display the total physical memory installed.

Back to [Memory Configuration Screen]

— [Advanced Screen] — [Screen Map]

3. Current Memory Speed

Option Values:

Help Text:

<Operational Memory Speed in MT/s>

<None>

Comments: is currently running.

Information only. Displays the speed in MT/s at which the memory

The supported memory speeds are 1066 MT/s, 1333 MT/s, and 1600 MT/s. The actual memory speed capability depends on the memory configuration.

Back to [Memory Configuration Screen]

— [Advanced Screen] — [Screen Map]

4. Memory Operating Speed Selection

Option Values: Auto

1066

1333

1600

Help Text:

Force specific Memory Operating Speed or use Auto setting.

Comments: Allows the user to select a specific speed at which memory will operate. Only speeds that are legitimate are available, that is, the user can only specify speeds less than or equal to the auto-selected Memory Operating Speed. The default

Auto setting will select the highest achievable Memory Operating Speed consistent with the DIMMs and processors installed.

1600 MT/s memory speed is available only on certain models.

Back to [Memory Configuration Screen]

— [Advanced Screen] — [Screen Map]

5. Correctable Error Threshold

Option Values: 20

116 Revision 2.0

BIOS Setup Interface

10

5

All

None

Help Text:

Threshold value for logging Correctable Errors (CE)

– Threshold of 10 (default) logs 10th

CE, "All" logs every CE and “None”’ means no CE logging. All and None are not valid with Rank Sparing.

Comments: Specifies how many Correctable Errors must occur before triggering the logging of a SEL Correctable Error Event. Only the first threshold crossing is logged, unless “All” is selected. “All” causes every CE that occurs to be logged. “None” suppresses CE logging completely.

This threshold is applied on a per-rank basis. The Correctable Error occurrences are counted for each memory rank. When any one rank accumulates a CE count equal to the CE Threshold, then a single CE SEL Event is logged, and all further CE logging is suppressed.

Note that the CE co unts are subject to a “leaky bucket” mechanism that reduces the count as a function of time, to keep from accumulating counts unnecessarily over the term of a long operational run.

Back to [Memory Configuration Screen]

— [Advanced Screen] — [Screen Map]

6. DIMM_A1

7. DIMM_A2

8. DIMM_B1

9. DIMM_B2

Help Text: <None>

Comments: Information only. Displays the status of each DIMM socket present on the board. There is one line for each DIMM socket present on the board.

For each DIMM socket, the DIMM Status reflects one of the following three possible states:

·

Installed & Operational

– There is a DDR3 DIMM installed and operational in this slot.

·

Not Installed

– There is no DDR3 DIMM installed in this slot.

Revision 2.0 117

BIOS Setup Interface

·

Failed/Disabled

– The DIMM installed in this slot has failed during initialization and/or was disabled during initialization.

For each DIMM that is in the Installed & Operational state, the DIMM Size in GB of that

DIMM is displayed. This is the physical size of the DIMM, regardless of how it is counted in the Effective Memory size.

Note: In “DIMM_XY”, X denotes the Channel Identifier A - P, and Y denotes the DIMM

Slot identifier 1 - 3 within the Channel. DIMM_A2 is the DIMM socket on Channel A, Slot

2. Not all boards have the same number of channels and slots

– this is dependent on the board features.

S1200V3RP boards can have DIMMs A1, A2 to B1, B2

Back to [Memory Configuration Screen]

— [Advanced Screen] — [Screen Map]

9.4.2.6 Mass Storage Controller Configuration

The Mass Storage Configuration screen allows the user to configure the Mass Storage controllers that are integrated into the server board on which the BIOS is executing. This includes only onboard Mass Storage controllers. Mass Storage controllers on add-in cards are not included in this screen, nor are other storage mechanisms such as USB-attached storage devices or Network Attached Storage.

There is one types of onboard controller configured in this screen, the AHCI SATA controller with SATA drive support and RAID support. There are also informational displays of AHCI controller configuration, and SATA Drive Information when applicable. If the presence of an

Intel

®

Storage Module is detected, the type of Storage Module is displayed as information-only.

To access this screen from the Main screen, select Advanced > Mass Storage Controller

Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen, then select the desired screen.

118 Revision 2.0

BIOS Setup Interface

Figure 24. Mass Storage Controller Configuration Screen

Screen Field Descriptions:

1. AHCI Capable SATA Controller

Option Values: Disabled

Compatibility

Enhanced

AHCI

RAID Mode

Help Text:

Compatibility provides PATA emulation on the SATA device

Enhanced provides Native SATA support

AHCI enables the Advanced Host Controller Interface, which provides Enhanced SATA functionality

RAID Mode provides host based RAID support on the onboard SATA ports

Comments: This option configures the onboard AHCI-capable SATA controller.

The number and type of ports it controls differs between board series.

Revision 2.0 119

BIOS Setup Interface

If the SATA Controller is Disabled, the SATA Ports will not operate, and any installed

SATA devices will be unavailable.

Compatibility provides PATA emulation on the SATA device, allowing the use of legacy

IDE/PATA drivers.

Enhanced provides Native SATA support using native SATA drivers included with the vast majority of current OSes.

AHCI enables the Advanced Host Controller Interface, which provides Enhanced SATA functionality plus possible additional functionality (Native Command Queuing, Hot Plug,

Staggered Spin Up). It uses AHCI drivers available for the majority of current OSes.

RAID Mode provides host based RAID support on the onboard SATA ports. RAID levels supported and required drivers depend on the RAID stack selected

Back to [Mass Storage Controller Configuration Screen]

— [Screen Map]

2. AHCI Capable RAID Options

Option Values: Intel(R) ESRT2 (LSI*)

Intel(R) RSTe

Help Text:

Intel(R) ESRT2 (Powered by LSI*): Supports RAID 0/1/10 and optional RAID 5 with

Intel

®

RAID C220 Upgrade Keys. Uses Intel ESRT2 drivers (based on LSI* MegaSR).

Intel(R) RSTe: Provides pass-through drive support. Also provides host based RAID

0/1/10/5 support. Uses Intel(R) RSTe iastor drivers.

Comments: This option only appears when the SATA Controller is enabled, and RAID Mode has been selected as the operational SATA Mode. This setting selects the RAID stack to be used for SATA RAID with the onboard AHCI SATA controller.

If a RAID Volume has not previously been created that is compatible with the RAID stack selected, it will be necessary to Save and Exit and reboot in order to create a RAID

Volume.

Note: This option does not appear on all boards.

Back to [Mass Storage Controller Configuration Screen]

— [Screen Map]

3. Intel(R) Storage Module

Option Values: None

<Name of Storage Module detected>

Names of Storage Modules supported at this time are:

120 Revision 2.0

BIOS Setup Interface

Intel(R) Integrated RAID Module

Intel(R) Integrated RAID Module RMS25PB040

Intel(R) Integrated RAID Module RMT3PB080

Intel(R) Integrated RAID Module RMS25CB080

Intel(R) Integrated RAID Module RMS25CB040

Intel(R) Integrated RAID Module RMT3CB080

Intel(R) Integrated RAID Module RMS25JB080

Intel(R) Integrated RAID Module RMS25JB040

Intel(R) Integrated RAID Module RMS25KB080

Intel(R) Integrated RAID Module RMS25KB040

Help Text: <None>

Comments: Information only. If no Intel

®

Storage Module is detected, then

None is displayed. This shows the customer the product name of the module installed, which helps in identifying drivers, support, documentation, etc.

Back to [Mass Storage Controller Configuration Screen]

— [Screen Map]

4. SATA Port (For Port numbers 0-6)

Option Values: Not Installed

Help Text:

<Drive Information>

<None>

Comments: Information only. The Drive Information, when present, will typically consist of the drive model identification and size for the disk drive installed on a particular port.

This Drive Information line is repeated for all 6 SATA Port for the onboard AHCI capable

SATA Controller. However, for any given board, only the ports which are physically populated on the board are shown. That is, a board which only implements the two 6

GB/s ports 0 and 1 will only show those two ports in this Drive Information list.

Back to [Mass Storage Controller Configuration Screen]

— [Screen Map]

9.4.2.7 PCI Configuration

The PCI Configuration screen allows the user to configure the PCI memory space used for onboard and add-in adapters, configure video options, and configure onboard adapter options.

Revision 2.0 121

BIOS Setup Interface

It also includes a selection option to go to the NIC Configuration screen.

To access this screen from the Main screen, select Advanced > PCI Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen, then select the desired screen.

Figure 25. PCI Configuration Screen

Screen Field Descriptions:

1. Maximize Memory below 4GB

Option Values: Enabled

Disabled

Help Text:

BIOS maximizes memory usage below 4GB for an OS without PAE support, depending on the system configuration. Only enable for an OS without PAE support.

Comments: When this option is enabled, BIOS makes as much memory available as possible in the 32-bit (4GB) address space, by limiting the amount of

PCI/PCIe Memory Address Space and PCIe Extended Configuration Space. This option should only be enabled for a 32-bit OS without PAE capability or without PAE enabled.

122 Revision 2.0

BIOS Setup Interface

Back to [PCI Configuration Screen]

— [Advanced Screen] — [Screen Map]

2. Memory Mapped I/O above 4 GB

Option Values: Enabled

Disabled

Help Text:

Enable or disable memory mapped I/O of 64-bit PCI devices to 4 GB or greater address space.

Comments: When enabled, PCI/PCIe Memory Mapped I/O for devices capable of 64-bit addressing is allocated to address space above 4GB, in order to allow larger allocations and avoid impacting address space below 4G.

Back to [PCI Configuration Screen]

— [Advanced Screen] — [Screen Map]

3. Memory Mapped I/O Size

Option Values: Auto

1G/2G/4G/8G/16G/32G/64G/128G/256G/512G/1024G

Help Text:

Sets MMIO Size: Auto -> 2G (default).

Comments: When Memory Mapped I/O above 4GB option enabled, this option sets the preserved MMIO size as PCI/PCIe Memory Mapped I/O for devices capable of

64-bit addressing. This option is grayed out when Memory Mapped I/O above 4GB option is disabled.

Back to [PCI Configuration Screen]

— [Advanced Screen] — [Screen Map]

4. Onboard Video

Option Values:

Help Text:

On-board video controller.

Enabled

Disabled

Warning: System video is completely disabled if this option is disabled and an add-in video adapter is not installed and Processor Integrated graphics

Revision 2.0 123

BIOS Setup Interface

Comments: When disabled, the system requires an add-in video card or

Processor Integrated graphics for the video to be seen. When there is no add-in video card or Processor Integrated graphics installed, Onboard Video is set to Enabled and grayed out so it cannot be changed.

Back to [PCI Configuration Screen]

— [Advanced Screen] — [Screen Map]

5. Processor Integrated Graphics

Option Values: Enabled

Disabled

Help Text:

Keep Processor Integrated Graphics enabled based on setup option.

Comments: is disabled.

Processor Integrated Graphics is completely disabled if this option

Notes: This configuration page is only visible on RM SKU.

Back to [PCI Configuration Screen]

— [Advanced Screen] — [Screen Map]

6. Primary Display

Option Values: PCI Add-on Card

Onboard Video

Processor Integrated graphics

Help Text:

Select which of Processor Integrated Graphics/Onboard Video/PCI Add-on Card

Graphics device should be Primary Display or select SG for Switchable GFX.

Comments:

Back to [PCI Configuration Screen]

— [Advanced Screen] — [Screen Map]

7. NIC Configuration

Option Values: <None>

Help Text:

View/Configure NIC information and settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the NIC Configuration group of configuration settings.

124 Revision 2.0

BIOS Setup Interface

Notes: This configuration page is not visible on some SKU.

Back to [PCI Configuration Screen]

— [Advanced Screen] — [Screen Map]

9.4.2.8 NIC Configuration

The NIC Configuration screen allows the user to configure the NIC controller options for BIOS

POST. It also displays the NIC MAC Addresses currently in use. This NIC Configuration screen handles network controllers built in on the baseboard (“onboard”) or installed as an IO Module

(IOM). It does not configure or report anything having to do with add-in network adapter cards.

To access this screen from the Main screen, select Advanced > PCI Configuration > NIC

Configuration. To move to another screen, press the <Esc> key to return to the PCI

Configuration screen, if necessary press the <Esc> key again to return to the Advanced screen, then select the desired screen.

There is usually one Onboard NIC built into the baseboard, although in some cases there are two Onboard NICs. There are several possible types of NICs which are incorporated into different boards. When an InfiniBand controller is on the baseboard, it appears as an Onboard

NIC.

Most boards in this family also can have an IO Module that installs on the board in a specialized connector. There are boards which can have two IO Modules installed.

The descriptive names of the Onboard NIC types are:

Intel

®

I210 Dual-Port Gigabit Ethernet Controller

For boards with only one Onboard NIC, the “Onboard NIC2” entries are not present on the screen. The number of “Port” options which are displayed for each NIC will match the number of ports the Onboard NIC presents.

The IO Modules currently available are:

Intel

®

I350 Quad-Port Gigabit Ethernet Module

Intel

®

I540 Dual-Port X540 10 Gigabit RJ-45 Module

Intel

®

82599 Dual-Port 10 Gigabit SFP+ Module

Intel

®

82575EB Dual-Port Gigabit Module

Mellanox* ConnectX-3* Single-Port InfiniBand FD14 Module

For the IO Module entries on the NIC Configuration screen, only entries for modules which are currently installed will be appear, and only ports which exist on those IO Modules will appear.

If an IO Module which had been installed is no longer installed when the system is booted, all

NIC Configuration entries which are specific to that IO Module will be reset to their default values and hidden. If a different IO Module is installed than had been previously installed, the module-specific settings will still be returned to defaults but not hidden. This will not necessarily

Revision 2.0 125

BIOS Setup Interface affect the Option ROM settings, which depend on the aggregate capabilities of all installed

Onboard and IO Module NICs.

For each NIC port which is present on an Onboard NIC or IO Module other than InfiniBand controllers, there will be a port-specific PXE Boot enabling option and a MAC Address display.

Onboard NICs and NIC ports also have enable/disable options. IO Modules and the ports on them cannot be disabled by BIOS.

InfiniBand controllers which appear as Onboard NICs or as IO Modules have a slightly different format. They do not have enable/disable options but they do have a choice of whether to enable loading and executing the embedded Option ROM for the controller, which will cause it to become bootable. For InfiniBand, both a GUID and a MAC Address are displayed. The GUID is used for InfiniBand Fabric operations, and the MAC Address is used when the controller is attached as an Ethernet device.

For non-InfiniBand NICs, there are different OPROMs for different protocols, which are also differentiated by speed, 1 Gb or 10 Gb. For a given protocol/speed, all Ethernet controllers of the same speed use the same Option ROM.

PXE

– there are two separate PXE Option ROMs, one for 1 Gb NICs and another for 10

Gb NICs. The two are independent of each other but each must be the only Option ROM enabled in its speed class. If 1 GbE PXE is enabled, then the iSCSI OPROM cannot be enabled. If 10 GbE PXE is enabled, then neither iSCSI nor 10 GbE FCoE may be enabled. iSCSI

– there is only one iSCSI Option ROM for both 1 GbE and 10 GbE NICs. If iSCSI is enabled, then neither PXE nor FCoE OPROMs may be enabled for the 1 GbE or 10

GbE NICs.

FCoE

– there is a 10 GbE FCoE Option ROM that supports the Intel

®

82599 NIC. When it is enabled, the iSCSI OPROM and the 10 GbE PXE OPROM must be disabled.

Note: These Option ROMs are only in support of onboard NICs and installed IO Modules. They do not support NICs on add-in network cards, even if the NIC on an add-in card is the same type of device as an onboard NIC or IO Module controller.

Only the Option ROMs for which controller capabilities are present are shown in the screen for selection. For example, if there are no 10 GbE NICs installed, then the 10 GbE OPROMs will not appear for selection. If controller capabilities are present but all controllers with those capabilities are disabled, then the relevant OPROM options will appear but will be disabled and grayed out and not changeable.

Similarly, when the PXE OPROM of a given speed is disabled, all PXE port enable/disable options using that OPROM will be disabled and grayed out. Conversely, if all ports are disabled for PXE, the PXE OPROM will be disabled and grayed out.

When a NIC Port is disabled, the PXE enable/disable option for it will be disabled and grayed out, and the MAC Address will be blank. When a NIC controller is disabled, all Ports and PXE options for that controller will become disabled and grayed out and all MAC Addresses for those ports will be blank. Conversely, if all ports for a given controller are disabled, the controller itself will appear as disabled.

126 Revision 2.0

BIOS Setup Interface

Screen Field Descriptions:

1. Wake on LAN (PME)

Revision 2.0

Figure 26. NIC Configuration Screen

127

BIOS Setup Interface

Option Values: Enabled

Disabled

Help Text:

Enables or disables PCI PME function for Wake on LAN capability from LAN adapters.

Comments: Enables/disables PCI/PCIe PME# signal to generate Power

Management Events (PME) and ACPI Table entries required for Wake on LAN (WOL).

However, note that this will enable WOL only with an ACPI-capable Operating System which has the WOL function enabled.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

2. PXE 1GbE Option ROM

Option Values:

Help Text:

Enabled

Disabled

Enable/Disable Onboard/IOM NIC PXE Option ROM Load.

Comments: This selection is to enable/disable the 1GbE PXE Option ROM that is used by all Onboard and IO Module 1 GbE controllers.

This option is grayed out and not accessible if the iSCSI Option ROM is enabled. It can co-exist with the 10 GbE PXE Option ROM, the 10 GbE FCoE Option ROM, or with an

InfiniBand controller Option ROM.

If the 1GbE PXE Option ROM is disabled, and no other Option ROM is enabled, the system cannot perform a Network Boot and cannot respond for Wake-on-LAN.

This 1GbE PXE option does not appear unless there is a 1 GbE NIC installed in the system as an Onboard or IO Module NIC.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

3. PXE 10GbE Option ROM

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Onboard/IOM NIC PXE Option ROM Load.

128 Revision 2.0

BIOS Setup Interface

Comments: This selection is to enable/disable the 10GbE PXE Option ROM that is used by all Onboard and IO Module 10 GbE controllers.

This option is grayed out and not accessible if the iSCSI Option ROM is enabled or the

10 GbE FCoE Option ROM is enabled. It can co-exist with the 1 GbE PXE Option ROM or with an InfiniBand controller Option ROM.

If the 10GbE PXE Option ROM is disabled, and no other Option ROM is enabled, the system cannot perform a Network Boot and cannot respond for Wake-on-LAN.

This 10GbE PXE option does not appear unless there is a 10 GbE NIC installed in the system as an Onboard or IO Module NIC.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

4. FCoE 10GbE Option ROM

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Onboard/IOM NIC FCoE Option ROM Load.

Comments: This selection is to enable/disable the 10GbE FCoE Option ROM that is used by all Onboard and IO Module 10 GbE controllers capable of FCoE support.

At the present time, only the Intel

®

82599 10 Gigabit SFP+ NIC supports FCoE for this family of server boards.

This option is grayed out and not accessible if the 10GbE PXE Option ROM is enabled or if the iSCSI Option ROM is enabled. It can co-exist with the 1GbE PXE Option ROM or with an InfiniBand controller Option ROM.

If the FCoE Option ROM is disabled, and no other Option ROM is enabled, the system cannot perform a Network Boot and cannot respond for Wake-on-LAN.

This FCoE option does not appear unless there is a FCoE-capable 10GbE NIC installed in the system as an Onboard or IO Module NIC.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

5. iSCSI 1GbE/10GbE Option ROM

Option Values: Enabled

Disabled

Help Text:

Revision 2.0 129

BIOS Setup Interface

Enable/Disable Onboard/IOM NIC iSCSI Option ROM Load.

Comments: This selection is to enable/disable the iSCSI Option ROM that is used by all Onboard and IO Module 1 GbE and 10 GbE controllers.

This option is grayed out and not accessible if the 1 GbE or 10GbE PXE Option ROM is enabled or if the 10 GbE FCoE Option ROM is enabled. It can co-exist with an InfiniBand controller Option ROM.

If the iSCSI Option ROM is disabled, and no other Option ROM is enabled, the system cannot perform a Network Boot and cannot respond for Wake-on-LAN.

This iSCSI option does not appear unless there is an iSCSI -capable NIC installed in the system as an Onboard or IO Module NIC.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

6. Onboard NIC1 Type

7. Onboard NIC2 Type

Option Values:

string:

<Onboard NIC Description>

Help Text:

Intel(R) I210 Dual-Port Gigabit Ethernet Controller

<None>

Comments: Information only. This is a display showing which NICs are available as Network Controllers integrated into the baseboard. Each of these Onboard

NICs will be followed by a section including a group of options that are specific to the type of NIC, either as an Ethernet controller or an InfiniBand controller.

If a board only has one onboard NIC, the second NIC Type and following options section will not appear.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

8. IO Module 1 Type

9. IO Module 2 Type

Option Values:

One of these strings:

<IO Module Description>

Intel(R) I350 Quad-Port Gigabit Ethernet Module

Intel(R) I540 Dual-Port X540 10 Gigabit RJ-45 Module

130 Revision 2.0

BIOS Setup Interface

Intel(R) 82599 Dual-Port 10 Gigabit SFP+ Module

Mellanox* ConnectX-3* Single-Port InfiniBand FD14 Module

Help Text: <None>

Comments: Information only. This is a display showing which Network

Controllers on IO Modules are installed on the baseboard. Each of these IO Module

NICs will be followed by a section including a group of options that are specific to the type of NIC, either as an Ethernet controller or an InfiniBand controller.

This descriptive screen image shows an example of an InifiniBand controller as IOM1. In a system with two IO Module connectors, an InfiniBand IO Module might be installed as either IOM1 or IOM2.

Most boards have only one IO Module connector. In any case, an IO Module Type and following options section will only appear when an IO Module is installed, and a second

IO Module Type and options section will only appear if there are two IO Modules installed.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

10. NIC1 Controller

11. NIC2 Controller

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Onboard Network Controller.

Comments: This will completely disable Onboard Network Controller NIC1 or

NIC2, along with all included NIC Ports and their associated options. That controller’s

NIC Ports, Port PXE options, and Port MAC Address displays will not appear.

This option only appears for onboard Ethernet controllers. It does not appear for onboard

InfiniBand controllers.

Ethernet controllers on IO Modules do not have a disabling function that can be controlled by BIOS, so there is no corresponding controller enable/disable option for an

IOM Ethernet controller.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

12. NIC2 InfiniBand Option ROM

13. IOM1 InfiniBand Option ROM

Revision 2.0 131

BIOS Setup Interface

14. IOM2 InfiniBand Option ROM

Option Values: Enabled

Disabled

Help Text:

Enable/Disable InfiniBand Controller Option ROM and FlexBoot.

Comments: This option will control whether the associated InfiniBand

Controller Option ROM is executed by BIOS during POST. This will also control whether the InfiniBand controller FlexBoot program appears in the list of bootable devices.

This option only appears for Onboard or IO Module InfiniBand controllers. It does not appear for Ethernet controllers.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

15. NIC2 Port1 GUID

16. IOM1 Port1 GUID

17. IOM2 Port1 GUID

Option Values: <GUID Display>

<None> Help Text:

Comments: Information only. 16 hex digits of the Port1 GUID of the InfiniBand controller for NIC2, IOM1, or IOM2.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

18. NIC1 Port1 PXE

19. NIC2 Port1 PXE

20. IOM1 Port1 PXE

21. IOM1 Port2 PXE

22. IOM1 Port3 PXE

23. IOM1 Port4 PXE

24. IOM2 Port1 PXE

25. IOM2 Port2 PXE

132 Revision 2.0

BIOS Setup Interface

26. IOM2 Port3 PXE

27. IOM2 Port4 PXE

Option Values: Enabled

Disabled

Help Text:

Enable/Disable Onboard/IOM NIC Port PXE Boot

Comments: This will enable or disable PXE Boot capability for Port<x, x = 1-4> of Onboard NIC<n, n = 1-2> or IO Module<n, n = 1-2>.

This option will not appear for ports on a NIC which is Disabled, or for individual ports when the corresponding NIC Port is disabled.

Only ports which actually exist for a particular NIC or IOM will appear in this section.

That is, Port1-Port4 will appear for a quad-port NIC, Port1-Port2 will appear for a dualport NIC, and only Port1 will appear for a single-port NIC.

The default state of each Port PXE Boot option is Enabled, if the corresponding PXE

Boot OPROM of the same speed is Enabled. If a PXE Boot OPROM for 1 GbE or 10

GbE changes from Disabled to Enabled, then the Port PXE Boot option becomes

Enabled for all ports of that speed

If the PXE Boot OPROM for1 GbE NICs or 10 GbE NICs is disabled, PXE Boot will be disabled and grayed out as unchangeable for all ports on NICs or IO Modules of that same speed.

Conversely, if PXE Boot is disabled for all ports of a given speed, the corresponding

PXE Option ROM will be disabled but not grayed out since it could be selected.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

28. NIC1 Port1 MAC Address

29. NIC2 Port1 MAC Address

30. IOM1 Port1 MAC Address

31. IOM1 Port2 MAC Address

32. IOM1 Port3 MAC Address

33. IOM1 Port4 MAC Address

34. IOM2 Port1 MAC Address

35. IOM2 Port2 MAC Address

Revision 2.0 133

BIOS Setup Interface

36. IOM2 Port3 MAC Address

37. IOM2 Port4 MAC Address

Option Values:

Help Text:

<Mac Address Display>

<None>

Comments: Information only. 12 hex digits of the MAC address of Port1- Port4 of the Network Controller corresponding to NIC1, NIC2, IOM1, or IOM2.

This display will appear only for ports which actually exist on the corresponding Network

Controller. If the Network Controller or port is disabled, the port MAC Address will not appear.

Back to [NIC Configuration Screen]

— [PCI Configuration Screen] — [Advanced Screen]

— [Screen Map]

9.4.2.9 Serial Port Configuration

The Serial Port Configuration screen allows the user to configure the Serial A and Serial B ports.

In Legacy ISA nomenclature, these are ports COM1 and COM2 respectively.

To access this screen from the Main screen, select Advanced > Serial Port Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen, then select the desired screen.

The primary usage for these serial ports is to enable Serial Console Redirection and Serial Over

LAN (SOL) capabilities. Either port can be used for Serial Console Redirection but SOL is only supported on Serial A.

Screen Field Descriptions:

1. Serial A Enable

Figure 27. Serial Port Configuration Screen

134 Revision 2.0

BIOS Setup Interface

Option Values: Enabled

Disabled

Help Text:

Enable or Disable Serial port A.

Comments:

Console Redirection.

Serial Port A can be used for either Serial Over LAN or Serial

Back to [Serial Port Configuration Screen]

— [Screen Map]

2. Address

Option Values: 3F8h

2F8h

3E8h

2E8h

Help Text:

Select Serial port A base I/O address.

Comments: Legacy I/O port address. This field should not appear when Serial

A port enable/disable does not appear.

Back to [Serial Port Configuration Screen]

— [Screen Map]

3. IRQ

Option Values:

Help Text:

3

4

Select Serial port A interrupt request (IRQ) line.

Comments: Legacy IRQ. This field should not appear when Serial A port enable/disable does not appear.

Back to [Serial Port Configuration Screen]

— [Screen Map]

4. Serial B Enable

Option Values: Enabled

Disabled

Revision 2.0 135

BIOS Setup Interface

Help Text:

Enable or Disable Serial port B.

Comments: Serial Port B can be used for Serial Console Redirection.

Back to [Serial Port Configuration Screen]

— [Screen Map]

5. Address

Option Values: 3F8h

2F8h

3E8h

2E8h

Help Text:

Select Serial port B base I/O address.

Comments: Legacy I/O port address.

Back to [Serial Port Configuration Screen]

— [Screen Map]

6. IRQ

Option Values:

Help Text:

3

4

Select Serial port B interrupt request (IRQ) line.

Comments: Legacy IRQ

Back to [Serial Port Configuration Screen]

— [Screen Map]

9.4.2.10 USB Configuration

The USB Configuration screen allows the user to configure the available USB controller options.

To access this screen from the Main screen, select Advanced > USB Configuration. To move to another screen, press the <Esc> key to return to the Advanced screen, then select the desired screen.

This screen should display all USB Mass Storage devices which have been detected in the system. These include USB-attached Hard Disk Drives (HDDs), Floppy Disk Drives (FDDs),

CDROM and DVDROM drives, and USB Flash Memory devices (USB Key, Keyfob, etc).

136 Revision 2.0

BIOS Setup Interface

Each USB Mass Storage device may be set to allow the media emulation for which it is formatted, or an emulation may be specified. For USB Flash Memory devices in particular, there are some restrictions:

·

A USB Key formatted as a CDROM drive will be recognized as an HDD.

·

A USB Key formatted without a Partition Table will be forced to FDD emulation.

·

A USB Key formatted with one Partition Table, and less than 528 MB in size, will be forced to FDD emulation

– otherwise if it is 528 MB or greater in size, it will be forced to HDD emulation.

Note: USB devices can be “hotplugged” during POST, and will be detected and “beeped”. They will be enumerated and displayed on this screen, though they may not be enumerated as bootable devices.

Figure 28. USB Configuration Screen

Screen Field Descriptions:

1. Detected USB Devices

Option Values:

Help Text:

<Number of USB devices detected in system>

<None>

Revision 2.0 137

BIOS Setup Interface

138

Comments: Information only. Displays the total number of USB devices of all types which have been detected in POST.

Note: There is one USB keyboard and one USB mice detected from the BMC KVM function under this item even no USB devices connected to the system.

Back to [USB Configuration Screen]

— [Screen Map]

2. USB Controller

Option Values:

Enabled

Disabled

Help Text:

[Enabled] - All on-board USB controllers are turned on and accessible by the OS.

[Disabled] - All on-board USB controllers are turned off and inaccessible by the OS.

Comments: When the USB controllers are Disabled, there is no USB IO available for either POST or the OS. In that case, all following fields on this screen are grayed out and inactive.

Back to [USB Configuration Screen]

— [Screen Map]

3. Legacy USB Support

Option Values: Enabled

Disabled

Auto

Help Text:

Enables Legacy USB support. AUTO option disables legacy support if no USB devices are connected. Disable option will only keep USB Keyboard devices available for EFI applications.

Comments: When Legacy USB Support is Disabled, USB devices are available only through OS drivers.

If the USB controller setting is Disabled, this field is grayed out and inactive.

Back to [USB Configuration Screen]

— [Screen Map]

4. XHCI Pre-Boot Driver

Option Values: Enabled

Disabled

Revision 2.0

BIOS Setup Interface

Help Text:

Enable/Disable XHCI Pre-Boot Driver support

Comments: and inactive.

If the USB controller setting is Disabled, this field is grayed out

Back to [USB Configuration Screen]

— [Screen Map]

5. XHCI Hand-off

Option Values:

Help Text:

Enabled

Disabled

This is a workaround for OSes without XHCI hand-off support. The XHCI ownership change should be claimed by XHCI driver

Comments: and inactive.

If the USB controller setting is Disabled, this field is grayed out

Back to [USB Configuration Screen]

— [Screen Map]

6. EHCI Hand-off

Option Values:

Help Text:

Enabled

Disabled

This is a workaround for OSes without EHCI hand-off support. The XHCI ownership change should be claimed by EHCI driver

Comments: and inactive.

If the USB controller setting is Disabled, this field is grayed out

Back to [USB Configuration Screen]

— [Screen Map]

7. Port 60/64 Emulation

Option Values:

Help Text:

Enabled

Disabled

Enables I/O port 60h/64h emulation support.

Revision 2.0 139

BIOS Setup Interface

This may be needed for legacy USB keyboard support when using an OS that is USB unaware.

Comments: and inactive.

If the USB controller setting is Disabled, this field is grayed out

Back to [USB Configuration Screen]

— [Screen Map]

8. Make USB Devices Non-Bootable

Option Values: Enabled

Disabled

Help Text:

Exclude USB in Boot Table.

[Enabled]- This will remove all USB Mass Storage devices as Boot options.

[Disabled] - This will allow all USB Mass Storage devices as Boot options.

Comments: This is a security option. When Disabled, the system cannot be booted directly to a USB device of any kind. USB Mass Storage devices may still be used for data storage.

If the USB controller setting is Disabled, this field is grayed out and inactive.

Back to [USB Configuration Screen]

— [Screen Map]

9. Device Reset Timeout

Option Values: 10 seconds

20 seconds

30 seconds

40 seconds

Help Text:

USB Mass Storage device Start Unit command timeout.

Setting to a larger value provides more time for a mass storage device to be ready, if needed.

Comments: and inactive.

If the USB controller setting is Disabled, this field is grayed out

Back to [USB Configuration Screen]

— [Screen Map]

140 Revision 2.0

BIOS Setup Interface

10. Mass Storage Devices:

Option Values: Auto

Floppy

Forced FDD

Hard Disk

CD-ROM

Help Text:

[Auto] - USB devices less than 530 MB are emulated as floppies.

[Forced FDD] - HDD formatted drive is emulated as an FDD (e.g., ZIP drive).

Comments: This field is hidden if no USB Mass Storage devices are detected.

This setup screen can show a maximum of eight USB Mass Storage devices on the screen. If more than eight devices are installed in the system, the ‘USB Devices Enabled’ displays the correct count but only the first eight devices discovered are displayed in this list.

If the USB controller setting is Disabled, this field is grayed out and inactive.

Back to [USB Configuration Screen]

— [Screen Map]

9.4.2.11 System Acoustic and Performance Configuration

The System Acoustic and Performance Configuration screen allows the user to configure the thermal control behavior of the system with respect to what parameters are used in the system’s

Fan Speed Control algorithms.

To access this screen from the Main screen, select Advanced > System Acoustic and

Performance Configuration. To move to another screen, press the <Esc> key to return to the

Advanced screen, then select the desired screen.

Revision 2.0

Figure 29. System Acoustic and Performance Configuration Screen

141

BIOS Setup Interface

Screen Field Descriptions:

1. Set Throttling Mode

Option Values:

Help Text:

Auto

Sets Thermal Throttling mode for memory, to control fans and DRAM power as needed to control DIMM temperatures.

[Auto]

– Auto Throttling Mode

[CLTM] - Closed Loop Thermal Management.

[OLTM] - Open Loop Thermal Management.

Closed Loop Thermal Management is supported only when ECC DIMM plugged. Open

Loop Thermal Management is not supported.

Comments: The Thermal Throttling Mode chosen reflects whether the DIMMs have Temperature Sensors (TSOD), and whether the chassis is an Intel chassis for which thermal data are available. Note that this is for thermal throttling only, independent of any controls imposed for the purpose of power limiting.

·

CLTM would be used with an OEM chassis and DIMMs with TSOD. The firmware does not change the offset registers for closed loop during runtime, although the

Management Engine can do so.

·

OLTM is intended for a system with UDIMMs which do not have TSOD. The thermal control registers are configured during POST, and the firmware does not change them.

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

2. Altitude

Option Values: 300m or less

301m-900m

901m-1500m

Higher than 1500m

Help Text:

[300m or less](980ft or less) Optimal near sea level.

[301m-900m](980ft-2950ft) Optimal performance setting at moderate elevation.

[901m-1500m](2950ft-4920ft) Optimal performance setting at high elevation.

142 Revision 2.0

BIOS Setup Interface

[Above 1500m](above 4920ft) Optimal performance setting at the highest elevations.

Comments: This option sets an altitude value in order to choose a Fan Profile that is optimized for the air density at the current altitude at which the system is installed.

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

3. Set Fan Profile

Option Values:

Help Text:

Performance

Acoustic

[Performance] - Fan control provides primary system cooling before attempting to throttle memory.

[Acoustic] - The system will favor using throttling of memory over boosting fans to cool the system if thermal thresholds are met.

Comments: This option allows the user to choose a Fan Profile that is optimized for maximizing performance or for minimizing acoustic noise.

When Performance is selected, the thermal conditions in the system are controlled by raising fan speed when necessary to raise cooling performance. This provides cooling without impacting system performance but may impact system acoustic performance

– fans running faster are typically louder.

When Acoustic is selected, then rather than increasing fan speed for additional cooling, the system will attempt first to control thermal conditions by throttling memory to reduce heat production. This regulates the system’s thermal condition without changing the acoustic performance but throttling memory may impact system performance.

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

4. Fan PWM Offset

Option Values:

[Entry Field 0

– 100, 0 is default]

Help Text:

Valid Offset 0 - 100.This number is added to the calculated PWM value to increase Fan

Speed.

Comments: This is a percentage by which the calculated fan speed will be increased. The user can apply positive offsets that result in increasing the minimum fan speeds.

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

5. Quiet Fan Idle Mode

Revision 2.0 143

BIOS Setup Interface

Option Values: Enabled

Disabled

Help Text:

Enabling this option allows the system fans to operate in Quiet ‘Fan off’ mode while still maintaining sufficient system cooling. In this mode, fan sensors become unavailable and cannot be monitored. There will be limited fan related event generation.

Comments: When enabled, this option allows fans to idle or turn off when sufficient thermal margin is available, decreasing the acoustic noise produced by the system and decreasing system power consumption. Fans will run as needed to maintain thermal control. The actual decrease in fan speed depends on the system thermal loading, which in turn depends on system configuration and workload.

While Quiet Fan Idle Mode is engaged, fan sensors become unavailable and are not monitored by the BMC.

Quiet Fan Idle Mode does not conflict with Fan PWM Offset (above)

– they work in concert, with Fan PWM Offset applied to fans in Quiet Fan Idle Mode just as when the fans are operating in “normal mode”. A Fan PWM Offset of zero is necessary for fans to actually stop turning.

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

9.4.2.12 Network Stack

Figure 30. Network Stack Screen

Screen Field Descriptions:

1. Network Stack

Option Values: Enabled

Disabled

Help Text:

Enable/Disable UEFI network stack

144 Revision 2.0

BIOS Setup Interface

Comments:

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

2. Ipv4 PXE support

Option Values: Enabled

Disabled

Help Text:

Enable Ipv4 PXE Boot Support. If disabled IPV4 PXE boot option will not be created.

Comments:

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

3. Ipv6 PXE support

Option Values:

Help Text:

Enabled

Disabled

Enable Ipv6 PXE Boot Support. If disabled IPV6 PXE boot option will not be created

Comments:

Back to [System Acoustic and Performance Configuration]

— [Screen Map]

9.4.2.13 Security Screen (Tab)

The Security screen allows the user to enable and set the Administrator and User passwords and to lock out the front panel buttons so they cannot be used. This screen also allows the user to enable and activate the Trusted Platform Module (TPM) security settings on those boards that support TPM.

Note that it is necessary to activate the TPM in order be able to enable Intel

®

Trusted Execution

Technology (TXT) on boards that support it. Changing the TPM state in Setup will require a

Hard Reset for the new state to become effective.

This BIOS supports (but does not require) “Strong Passwords” for security. The “Strong

Password” criteria for both Administrator and User passwords require that passwords be between 8 and 14 characters at length, and a password must contain at least one casesensitive alphabetic character, one numeric character, and one special character. A warning is given when a password is set which does not meet the Strong Password criteria but the password is accepted.

For further security, the BIOS optionally may require a Power on Password to be entered in early POST in order to boot the system. When Power On Password is enabled, POST is halted

Revision 2.0 145

BIOS Setup Interface soon after power on while the BIOS queries for a Power On Password. Either the Administrator or the User password may be entered for a Power on Password.

To access this screen from the Main screen or other toplevel “Tab” screen, press the right or left arrow keys to traverse the tabs at the top of the Setup screen until the Security screen is selected.

Figure 31. Security Screen

Screen Field Descriptions:

1. Administrator Password Status

Option Values: Installed

Not Installed

Help Text: <None>

Comments:

Password.

Information only. Indicates the status of the Administrator

Back to [Security Screen]

— [Screen Map]

2. User Password Status

Option Values:

Help Text: <None>

Installed

Not Installed

146 Revision 2.0

BIOS Setup Interface

Comments: Information only. Indicates the status of the User Password.

Back to [Security Screen]

— [Screen Map]

3. Set Administrator Password

Option Values: [Entry Field

– 0-14 characters]

Help Text:

Administrator password is used if Power On Password is enabled and to control change access in BIOS Setup. Length is 1-14 characters. Case sensitive alphabetic, numeric and special characters !@#$%^&*()-_+=? are allowed.

Note: Administrator password must be set in order to use the User account.

Comments: This password controls “change” access to Setup. The

Administrator has full access to change settings for any Setup options, including setting the Administrator and User passwords.

When Power On Password protection is enabled, the Administrator password may be used to allow the BIOS to complete POST and boot the system.

Deleting all characters in the password entry field removes a password previously set.

Clearing the Administrator Password also clears the User Password.

If invalid characters are present in the password entered, it will not be accepted, and there will be popup error message:

Password entered is not valid. Only case sensitive alphabetic, numeric and special characters !@#$%^&*()-_+=? are allowed.

The Administrator and User passwords must be different. If the password entered is the same as the User password, it will not be accepted, and there will be popup error message:

Password entered is not valid. Administrator and User passwords must be different.

Strong passwords are encouraged, although not mandatory. If a password is entered which does not meet the “Strong Password” criteria, there will be a popup warning message:

Warning

– a Strong Password should include at least one each case sensitive alphabetic, numeric, and special character. Length should be 8 to 14 characters.

Back to [Security Screen]

— [Screen Map]

4. Set User Password

Option Values:

[Entry Field

– 0-14 characters]

Revision 2.0 147

BIOS Setup Interface

Help Text:

User password is used if Power On Password is enabled and to allow restricted access to BIOS Setup. Length is 1-14 characters. Case sensitive alphabetic, numeric and special characters !@#$%^&*()-_+=? are allowed.

Note: Removing the administrator password also removes the user password.

Comments: The User password is available only if the Administrator Password has been installed. This option protects Setup settings as well as boot choices. The User

Password only allows limited access to the Setup options, and no choice of boot devices.

When Power On Password protection is enabled, the User password may be used to allow the BIOS to complete POST and boot the system.

The password format and entry rules and popup error and warning message are the same for the User password as for the Administrator password (see above).

Back to [Security Screen]

— [Screen Map]

5. Power On Password

Option Values: Enabled

Disabled

Help Text:

Enable Power On Password support. If enabled, password entry is required in order to boot the system.

Comments: When Power On Password security is enabled, the system will halt soon after power on and the BIOS will ask for a password before continuing POST and booting. Either the Administrator or User password may be used.

If an Administrator password has not been set, this option will be grayed out and unavailable. If this option is enabled and the Administrator password is removed, that will also disable this option.

Back to [Security Screen]

— [Screen Map]

6. Front Panel Lockout

Option Values: Enabled

Disabled

Help Text:

If enabled, locks the power button OFF function and the reset and NMI Diagnostic

Interrupt buttons on the system’s front panel. If [Enabled] is selected, power off and reset

148 Revision 2.0

BIOS Setup Interface

must be controlled via a system management interface, and the NMI Diagnostic Interrupt is not available.

Note: This option is not visible on S1200V3RP Server Board.

Back to [Security Screen]

— [Screen Map]

7. TPM State

Option Values: <Displays current TPM Device State>

May be:

Enabled & Activated

Enabled & Deactivated

Disabled & Activated

Disabled & Deactivated

Help Text: <None>

Information only. Shows the current TPM device state. Comments:

A Disabled TPM device does not execute commands that use the TPM functions and

TPM security operations are not available.

An Enabled & Deactivated TPM is in the same state as a disabled TPM, except that setting of the TPM ownership is allowed if it is not present already.

An Enabled & Activated TPM executes all commands that use the TPM functions and

TPM security operations are also available.

Note: This option appears only on boards equipped with a TPM.

Back to [Security Screen]

— [Screen Map]

8. TPM Administrative Control

Option Values: No Operation

Help Text:

Turn On

Turn Off

Clear Ownership

[No Operation] - No changes to current state.

Revision 2.0 149

BIOS Setup Interface

[Turn On] - Enables and activates TPM.

[Turn Off] - Disables and deactivates TPM.

[Clear Ownership] - Removes TPM ownership & returns TPM to factory default state.

Note: setting returns to [No Operation] on every boot.

Comments: Any Administrative Control operation selected will require the system to perform a Hard Reset in order to become effective.

Note: This option appears only on boards equipped with a TPM.

Back to [Security Screen]

— [Screen Map]

9.4.2.14 Server Management Screen (Tab)

The Server Management screen allows the user to configure several server management features. This screen also provides an access point to the screens for configuring Console

Redirection, displaying system information, and controlling the BMC LAN configuration.

To access this screen from the Main screen or other toplevel “Tab” screen, press the right or left arrow keys to traverse the tabs at the top of the Setup screen until the Server Management screen is selected.

150 Revision 2.0

BIOS Setup Interface

Figure 32. Server Management Screen

Screen Field Descriptions:

1. Assert NMI on SERR

Option Values: Enabled

Disabled

Help Text:

On SERR, generate an NMI and log an error.

Note: [Enabled] must be selected for the Assert NMI on PERR setup option to be visible.

Comments: This option allows the system to generate an NMI when an SERR occurs, which is a method Legacy Operating System error handlers may use instead of processing a Machine Check.

Revision 2.0 151

BIOS Setup Interface

Back to [Server Management Screen]

— [Screen Map]

2. Assert NMI on PERR

Option Values: Enabled

Disabled

Help Text:

On PERR, generate an NMI and log an error.

Note: This option is only active if the Assert NMI on SERR option has [Enabled] selected.

Comments: This option allows the system to generate an NMI when a PERR occurs, which is a method Legacy Operating System error handlers may use instead of processing a Machine Check.

Back to [Server Management Screen]

— [Screen Map]

3. Reset on CATERR

Option Values: Enabled

Disabled

Help Text:

When enabled system gets reset upon encountering Catastrophic Error (CATERR); when disabled system does not get reset on CATERR.

Comments: This option controls whether the system will be reset when the

“Catastrophic Error” CATERR# signal is held asserted, rather than just pulsed to generate an SMI. This indicates that the processor has encountered a fatal hardware error.

Note: If “Reset on CATERR” is Disabled, this can result in a system hang for certain error conditions, possibly with the system unable to update the System Status LED or log an error to the SEL before hanging.

Back to [Server Management Screen]

— [Screen Map]

4. Resume on AC Power Loss

Option Values: Stay Off

Last State

Power On

Help Text:

152 Revision 2.0

BIOS Setup Interface

System action to take on AC power loss recovery.

[Stay Off] - System stays off.

[Last State] - System returns to the same state before the AC power loss.

[Power On] - System powers on.

Comments: This option controls the policy that the BMC will follow when AC power is restored after an unexpected power outage. The BMC will either hold DC power off or always turn it on to boot the system, depending on this setting

– and in the case of

Last State, depending on whether the power was on and the system was running before the AC power went off.

When this setting is changed in Setup, the new setting will be sent to the BMC. However, the BMC maintains (“owns”) this Power Restore Policy setting, and it can be changed independently with an IPMI command to the BMC. BIOS gets this setting from the BMC early in POST, and also for the Setup Server Management screen.

Back to [Server Management Screen]

— [Screen Map]

5. Power Restore Delay

Option Values: Disabled

Auto

Fixed

Help Text:

Allows a delay in powering up after a power failure, to reduce peak power requirements.

The delay can be fixed or automatic between 25-300 seconds.

Comments: When the AC power resume policy (above) is either Power On or

Last State, this option allows a delay to be taken after AC power is restored before the system actually begins to power up. This delay can be either a fixed time or an

“automatic” time, where “automatic” means that the BIOS will select a randomized delay time of 25-300 seconds when it sends the Power Restore Delay setting to the BMC.

This option will be grayed out and unavailable when the AC power resume policy is Stay

Off.

The Power Restore Delay setting is maintained by BIOS. This setting does not take effect until a reboot is done. Early in POST, the Power Restore Policy is read from the

BMC, and if the policy is Power On or Last State, the delay settings are sent to the BMC.

Bear in mind that even if the Power Restore Delay is Disabled, there will still be a delay of about 20 seconds while the BMC itself boots up after AC power is restored.

Revision 2.0 153

BIOS Setup Interface

Note: This Power Restore Delay option applies only to powering on when AC is applied.

It has no effect on powering the system up using the Power Button on the Front Panel. A

DC power on using the Power Button is not delayed.

The purpose of this delay is to avoid having all systems draw “startup surge” power at the same time. Different systems or racks of systems can be set to different delay times to spread out the startup power draws. Alternatively, all systems can be set to Automatic, and then each system will wait for a random period before powering up.

Back to [Server Management Screen]

— [Screen Map]

6. Power Restore Delay Value

Option Values:

[Entry Field 25

– 300, 25 is default]

Help Text:

Fixed time period 25-300 seconds for Power Restore Delay.

Comments: When the power restore policy is Power On or Last State, and the

Power Restore Delay selection is Fixed, this field allows for specifying how long in seconds that fixed delay will be.

When the Power Restore Delay is Disabled or Auto, this field will be grayed out and unavailable.

The Power Restore Delay Value setting is maintained by BIOS. This setting does not take effect until a reboot is done. Early in POST, the Power Restore Policy is read from the BMC, and if the policy is Power On or Last State, the delay settings are sent to the

BMC. When the Power Restore Delay setting is Fixed, this delay value is used to provide the length of the delay.

Back to [Server Management Screen]

— [Screen Map]

7. Clear System Event Log

Option Values: Enabled

Disabled

Help Text:

If enabled, clears the System Event Log. All current entries will be lost.

Note: This option is reset to [Disabled] after a reboot.

Comments: This option sends a message to the BMC to request it to clear the

System Event Log. The log will be clear ed, and then the “Clear” action itself will be logged as an event. This gives the user a time/date for when the log was cleared.

Back to [Server Management Screen]

— [Screen Map]

154 Revision 2.0

BIOS Setup Interface

8. FRB-2 Enable

Option Values:

Help Text:

Enabled

Disabled

Fault Resilient Boot (FRB).

BIOS programs the BMC watchdog timer for approximately 6 minutes. If BIOS does not complete POST before the timer expires, the BMC will reset the system.

Comments: This option controls whether the system will be reset if the BMC

Watchdog Timer detects what appears to be a hang during POST. When the BMC

Watchdog Timer is purposed as an FRB 2 timer, it is initially set to allow 6 minutes for

POST to complete.

However, the FRB 2 Timer is suspended during times when some lengthy operations are in progress, like executing Option ROMS, during Setup, and when BIOS is waiting for a password or for input to the F6 BBS Boot Menu. The FRB 2 Timer is also suspended while POST is paused with the <Pause> key.

Back to [Server Management Screen]

— [Screen Map]

9. OS Boot Watchdog Timer

Option Values:

Help Text:

Enabled

Disabled

BIOS programs the watchdog timer with the timeout value selected. If the OS does not complete booting before the timer expires, the BMC will reset the system and an error will be logged.

Requires OS support or Intel Management Software Support.

Comments: This option controls whether the system will set the BMC

Watchdog to detect an apparent hang during OS boot. BIOS sets the timer before starting the OS bootstrap load procedure. If the OS Load Watchdog Timer times out, then presumably the OS failed to boot properly.

If the OS does boot up successfully, it must be aware of the OS Load Watchdog Timer and immediately turn it off before it expires. The OS may turn off the timer, or more often the timer may be repurposed as an OS Watchdog Timer to protect against runtime OS hangs.

Unless the OS does have timer-aware software to support the OS Load Watchdog Timer, the system will be unable to boot successfully with the OS Load Watchdog Timer

Revision 2.0 155

BIOS Setup Interface enabled. When the timer expires without having been reset or turned off, the system will either reset or power off repeatedly.

Back to [Server Management Screen]

— [Screen Map]

10. OS Boot Watchdog Timer Policy

Option Values: Power off

Reset

Help Text:

If the OS watchdog timer is enabled, this is the system action taken if the watchdog timer expires.

[Reset] - System performs a reset.

[Power Off] - System powers off.

Comments: This option is grayed out and unavailable when the O/S Boot

Watchdog Timer is disabled.

Back to [Server Management Screen]

— [Screen Map]

11. OS Boot Watchdog Timer Timeout

Option Values: 5 minutes

10 minutes

15 minutes

Help Text:

20 minutes

If the OS watchdog timer is enabled, this is the timeout value BIOS will use to configure the watchdog timer.

Comments: This option is grayed out and unavailable when the O/S Boot

Watchdog Timer is disabled.

Back to [Server Management Screen]

— [Screen Map]

12. Plug & Play BMC Detection

Option Values: Enabled

Disabled

Help Text:

156 Revision 2.0

BIOS Setup Interface

If enabled, the BMC will be detectable by OSes which support plug and play loading of an IPMI driver. Do not enable this option if your OS does not support this driver.

Comments: This option controls whether the OS Server Management

Software will be able to find the BMC and automatically load the correct IPMI support software for it. If your OS does not support Plug & Play for the BMC, you will not have the correct IPMI driver software loaded.

Back to [Server Management Screen]

— [Screen Map]

13. EuP LOT6 Off-Mode

Option Values: Enabled

Disabled

Help Text:

Enable/disable Ecodesign EuP LOT6 “Deep Sleep” Off-Mode for near-zero energy use when powered off.

Comments:

This option controls whether the system goes into “Deep Sleep” or more conventional S5 “Soft-Off” when powered off. “Deep Sleep” state uses less energy than S5 but S5 can start up faster and can allow a Wake on LAN action (which cannot be done from a Deep Sleep state).

This option will not appear on platforms which do not support EuP LOT6 Off-Mode.

Back to [Server Management Screen]

— [Screen Map]

14. Console Redirection

Option Values: <None>

Help Text:

View/Configure Console Redirection information and settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the Console Redirection group of configuration settings.

Back to [Server Management Screen]

— [Screen Map]

15. System Information

Option Values:

Help Text:

View System Information.

<None>

Revision 2.0 157

BIOS Setup Interface

Comments: Selection only. Select this line and press the <Enter> key to go to the System Information group of configuration settings.

Back to [Server Management Screen]

— [Screen Map]

16. BMC LAN Configuration

Option Values: <None>

Help Text:

View/Configure BMC LAN and user settings.

Comments: Selection only. Select this line and press the <Enter> key to go to the BMC LAN Configuration group of configuration settings.

Back to [Server Management Screen]

— [Screen Map]

9.4.2.15 Console Redirection

The Console Redirection screen allows the user to enable or disable Console Redirection for

Remote System Management, and to configure the connection options for this feature.

To access this screen from the Main screen, select Server Management > Console Redirection.

To move to another screen, press the <Esc> key to return to the Server Management screen, then select the desired screen.

When Console Redirection is active, all POST and Setup displays are in Text Mode. The Quiet

Boot setting is disregarded, and the Text Mode POST Diagnostic Screen will be displayed regardless of the Quiet Boot setting. This is due to the limitations of Console Redirection, which is based on data terminal emulation using a serial data interface to transfer character data.

Console Redirection can use either of the two Serial Ports provided by the SuperIO in the BMC.

However, if Console Redirection is to be coordinated with Serial Over LAN, the user should be aware that SOL is only supported through Serial Port A.

158

Figure 33. Console Redirection Screen

Revision 2.0

BIOS Setup Interface

Screen Field Descriptions:

1. Console Redirection

Option Values:

Help Text:

Disabled

Serial Port A

Serial Port B

Console redirection allows a serial port to be used for server management tasks.

[Disabled] - No console redirection.

[Serial Port A] - Configure serial port A for console redirection.

Enabling this option will disable display of the Quiet Boot logo screen during POST.

Comments: Serial Console Redirection can use either Serial Port A or Serial

Port B. If SOL is also going to be configured, note that SOL is only supported through

Serial Port A

When Console Redirection is set to Disabled, all other options on this screen will be grayed out and unavailable.

Only Serial Ports which are Enabled should be available to choose for Console

Redirection. If neither Serial A nor Serial B is set to Enabled, then Console Redirection will be forced to Disabled, and grayed out as inactive. In that case, all other options on this screen will also be grayed.

Back to [Console Redirection Screen]

— [Server Management Screen] — [Screen Map]

2. Flow Control

Option Values: None

RTS/CTS

Help Text:

Flow control is the handshake protocol.

This setting must match the remote terminal application.

[None] - Configure for no flow control.

[RTS/CTS] - Configure for hardware flow control.

Comments: Flow control is necessary only when there is a possibility of data overrun. In that case the Request To Send/Clear to Send (RTS/CTS) hardware

Revision 2.0 159

BIOS Setup Interface handshake is a relatively conservative protocol which can usually be configured at both ends.

When Console Redirection is set to Disabled, this option will be grayed out and unavailable.

Back to [Console Redirection Screen]

— [Server Management Screen] — [Screen Map]

3. Baud Rate

Option Values: 9.6k

19.2k

38.4k

57.6k

115.2k

Help Text:

Serial port transmission speed. This setting must match the remote terminal application.

Comments: In most modern Server Management applications, serial data transfer is consolidated over an alternative faster medium like LAN, and 115.2k is the speed of choice.

When Console Redirection is set to Disabled, this option will be grayed out and unavailable.

Back to [Console Redirection Screen]

— [Server Management Screen] — [Screen Map]

4. Terminal Type

Option Values: PC-ANSI

VT100

VT100+

VT-UTF8

Help Text:

Character formatting used for console redirection. This setting must match the remote terminal application.

Comments: The VT100 and VT100+ terminal emulations are essentially the same. VT-UTF8 is a UTF8 encoding of VT100+. PC-ANSI is the native character encoding used by PC-compatible applications and emulators.

160 Revision 2.0

BIOS Setup Interface

When Console Redirection is set to Disabled, this option will be grayed out and unavailable.

Back to [Console Redirection Screen]

— [Server Management Screen] — [Screen Map]

5. Legacy OS Redirection

Option Values: Enabled

Disabled

Help Text:

This option enables legacy OS redirection (i.e., DOS) on serial port. If it is enabled, the associated serial port is hidden from the legacy OS.

Comments:

Operating Systems which are “redirection-aware” implement their own Console Redirection mechanisms. For a Legacy OS which is not “aware”, this option allows the BIOS to handle redirection.

When Console Redirection is set to Disabled, this option will be grayed out and unavailable.

Back to [Console Redirection Screen]

— [Server Management Screen] — [Screen Map]

6. Terminal Resolution

Option Values:

Help Text:

80x24

100x31

Remote Terminal Resolution.

Comments: This option allows the use of a larger terminal screen area, although it does not change Setup displays to match.

When Console Redirection is set to Disabled, this option will be grayed out and unavailable.

Back to [Console Redirection Screen]

— [Server Management Screen] — [Screen Map]

9.4.2.16 System Information

The System Information screen allows the user to view part numbers, serial numbers, and firmware revisions. This is an Information Only screen.

To access this screen from the Main screen, select Server Management > System Information.

To move to another screen, press the <Esc> key to return to the Server Management screen, then select the desired screen.

Revision 2.0 161

BIOS Setup Interface

Figure 34. System Information Screen

Screen Field Descriptions:

1. Board Part Number

Option Values:

Help Text:

<Part Number display>

<None>

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

2. Board Serial Number

Option Values:

Help Text:

<Serial Number display>

<None>

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

3. System Part Number

Option Values:

Help Text:

<Part Number display>

<None>

Comments: Information only.

162 Revision 2.0

BIOS Setup Interface

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

4. System Serial Number

Option Values:

Help Text:

<Serial Number display>

<None>

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

5. Chassis Part Number

Option Values:

Help Text:

<Part Number display>

<None>

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

6. Chassis Serial Number

Option Values:

Help Text:

<Serial Number display>

<None>

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

7. Asset Tag

Option Values: <Asset Tag-display>

<None> Help Text:

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

8. BMC Firmware Revision

Option Values:

Help Text:

<BMC FW Rev display>

<None>

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

Revision 2.0 163

BIOS Setup Interface

9. ME Firmware Revision

Option Values:

Help Text:

<ME FW Rev display>

<None>

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

10. SDR Revision

Option Values: <SDR Rev display>

<None> Help Text:

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

11. UUID

Option Values: <UUID display>

<None> Help Text:

Comments: Information only.

Back to [System Information Screen]

— [Server Management Screen] — [Screen Map]

9.4.2.17 BMC LAN Configuration

To access this screen from the Main screen, select Server Management > BMC LAN

Configuration. To move to another screen, press the <Esc> key to return to the Server

Management screen, then select the desired screen.

The BMC configuration screen allows the user to configure the BMC Baseboard LAN channel and an Intel

®

RMM4 LAN channel, and to manage BMC User settings for up to five BMC Users.

An Intel

®

RMM4 Management Module may be installed in the server system.

If the Management Module is installed, it may also have a Dedicated Server Management NIC

Module (DMN) installed with it. In that case, the LAN settings for the Intel

®

RMM4 with

Dedicated Server Management NIC may be configured.

When there is no Management Module installed in the system, or there is an Intel

®

RMM4-Lite without a DMN installed, the LAN settings specific to the Intel

®

RMM4 are grayed out and not available.

This screen has a choice of IPv4 or IPv6 addressing. When IPv6 is disabled, only the IPv4 addressing options appear. When IPv6 is enabled, the IPv4 options are grayed out and unavailable, and there is an additional section active for IPv6-addressing. This is true for both

164 Revision 2.0

BIOS Setup Interface the Baseboard LAN configuration and the Intel

®

RMM4 with Dedicated Server Management NIC

Module.

IP addresses for either IPv4 or IPv6 addressing can be assigned by static IP addresses manually typed in, or by dynamic IP addresses supplied by a Dynamic Host Configuration

Protocol (DHCP) server. IPv6 addressing can also be provided by “stateless autoconfiguration” which does not require a DHCP server.

The BMC LAN Configuration screen is unusual in that the LAN Configuration parameters are maintained by the BMC itself, so this screen is just a User Interface to the BMC configuration.

As such, the initial values of the LAN options shown on the screen are acquired from the BMC when this screen is initially accessed by a user,. Any values changed by the user are communicated back to the BMC when a “Save Changes” or “Save Changes and Exit” action is performed. If a “Discard Changes” or “Discard Changes and Exit” action is performed instead, any accumulated changes from this screen will be disregarded and lost.

Revision 2.0 165

BIOS Setup Interface

Screen Field Descriptions:

1. IP Source

Option Values:

Help Text:

Figure 35. BMC LAN Configuration Screen

Static

Dynamic

166 Revision 2.0

BIOS Setup Interface

Select BMC IP Source: If [Static], IP parameters may be edited. If [Dynamic], these fields are display-only and IP address is acquired automatically (DHCP).

Comments: This specifies the IP Source for IPv4 addressing for the

Baseboard LAN. There is a separate IP Source field for the Intel

®

RMM4 LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC, and its setting determines whether the other Baseboard LAN IPv4 addressing fields are display-only (when Dynamic) or can be edited (when Static).

When IPv6 addressing is enabled, this field is grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

2. IP Address

Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]

Help Text:

View/Edit IP Address. Press <Enter> to edit.

Comments: This specifies the IPv4 Address for the Baseboard LAN. There is a separate IPv4 Address field for the Intel

®

RMM4 LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IP Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).

When IPv6 addressing is enabled, this field is grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

3. Subnet Mask

Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]

Help Text:

View/Edit Subnet Mask. Press <Enter> to edit.

Comments: This specifies the IPv4 addressing Subnet Mask for the

Baseboard LAN. There is a separate IPv4 Subnet Mask field for the Intel® RMM4 LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IP Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).

Revision 2.0 167

BIOS Setup Interface

When IPv6 addressing is enabled, this field is grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

4. Gateway IP

Option Values:

[Entry Field 0.0.0.0, 0.0.0.0 is default]

Help Text:

View/Edit Gateway IP. Press <Enter> to edit.

Comments: This specifies the IPv4 addressing Gateway IP for the Baseboard

LAN. There is a separate IPv4 Gateway IP field for the Intel® RMM4 LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IP Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).

When IPv6 addressing is enabled, this field is grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

5. IPv6

Option Values: Enabled

Disabled

Help Text:

Option to Enable/Disable IPv6 addressing and any IPv6 network traffic on these channels.

Comments: The initial value for this field is acquired from the BMC. It may be changed in order to switch between IPv4 and IPv6 addressing technologies.

When this option is set to Disabled, all other IPv6 fields will not be visible for the

Baseboard LAN and Intel

®

RMM4 DMN (if installed). When IPv6 addressing is Enabled, all IPv6 fields for the Baseboard LAN and Intel

®

RMM4 DMN will become visible, and all

IPv4 fields will be grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

6. IPv6 Source

Option Values: Static

Dynamic

168 Revision 2.0

BIOS Setup Interface

Help Text:

Auto

Select BMC IPv6 source: If [Static], IPv6 parameters may be edited. If [Dynamic], these fields are display-only and IPv6 address is acquired automatically (DHCP). If [Auto], these fields are display-only and IPv6 address is acquired using ICMPv6 router / neighbor discovery.

Comments: This specifies the IP Source for IPv6 addressing for the

Baseboard LAN configuration. There is a separate IPv6 Source field for the Intel

®

RMM4

LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is Enabled, the initial value for this field is acquired from the BMC, and its setting determines whether the other Baseboard LAN IPv6 addressing fields are display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

7. IPv6 Address

Option Values:

[Entry Field 0000:0000:0000:0000:0000:0000:0000:0000,

0000:0000:0000:0000:0000:0000:0000:0000 is default]

Help Text:

View/Edit IPv6 address. Press <Enter> to edit. IPv6 addresses consist of 8 hexadecimal

4 digit numbers separated by colons.

Comments: This specifies the IPv6 Address for the Baseboard LAN. There is a separate IPv6 Address field for the Intel

®

RMM4 LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

8. Gateway IPv6

Option Values: [Entry Field 0000:0000:0000:0000:0000:0000:0000:0000,

0000:0000:0000:0000:0000:0000:0000:0000 is default]

Help Text:

Revision 2.0 169

BIOS Setup Interface

View/Edit Gateway IPv6 address. Press <Enter> to edit. Gateway IPv6 addresses consist of 8 hexadecimal 4 digit numbers separated by colons.

Comments: This specifies the Gateway IPv6 Address for the Baseboard LAN.

There is a separate Gateway IPv6 Address field for the Intel

®

RMM4 LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

9. IPv6 Prefix Length

Option Values: [Entry Field 0

– 128, 64 is default]

Help Text:

View/Edit IPv6 Prefix Length from zero to 128 (default 64). Press <Enter> to edit.

Comments: This specifies the IPv6 Prefix Length for the Baseboard LAN.

There is a separate IPv6 Prefix Length field for the Intel

®

RMM4 LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

10. Intel(R) RMM4

Option Values: Not Present

Intel(R) RMM4-Lite

Intel(R) RMM4 + DMN

Help Text: <None>

Comments: Information only. Displays whether an Intel

®

RMM4 component is currently installed. This information may come from querying the BMC.

Intel

®

RMM4-Lite is the Management Module without the Dedicated Server Management

NIC Module. When this is present, or if the Management Module is Not Present at all, the fields for Intel

®

RMM4 LAN Configuration will not be visible.

170 Revision 2.0

BIOS Setup Interface

When an Intel

®

RMM4 + DMN is installed, the options for Intel

®

RMM4 LAN

Configuration will be visible. When IPv6 is Disabled, the IPv4 configuration fields will be visible and the IPv6 configuration fields will not be visible. When IPv6 is Enabled, the

IPv4 fields will be grayed out and inactive, while the IPv6 Configuration fields will be visible.

In either case, the Intel

®

RMM4 section IP Source or IPv6 Source will determine whether the IPv4 or IPv6 address fields are display-only or can be edited.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

11. IP Source

Option Values: Static

Dynamic

Help Text:

Select RMM4 IP source: If [Static], IP parameters may be edited. If [Dynamic], these fields are display-only and IP address is acquired automatically (DHCP).

Comments: This specifies the IP Source for IPv4 addressing for the Intel

®

RMM4 DMN LAN connection. There is a separate IP Source field for the Baseboard LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC, and its setting determines whether the other Intel

®

RMM4 DMN LAN IPv4 addressing fields are display-only (when Dynamic) or can be edited (when Static).

When IPv6 addressing is enabled, this field is grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

12. IP Address

Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]

Help Text:

View/Edit IP Address. Press <Enter> to edit.

Comments: This specifies the IPv4 Address for the Intel

®

RMM4 DMN LAN.

There is a separate IPv4 Address field for the Baseboard LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IP Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).

When IPv6 addressing is enabled, this field is grayed out and inactive.

Revision 2.0 171

BIOS Setup Interface

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

13. Subnet Mask

Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]

Help Text:

View/Edit Subnet Mask. Press <Enter> to edit.

Comments: This specifies the IPv4 addressing Subnet Mask for the Intel®

RMM4 DMN LAN. There is a separate IPv4 Subnet Mask field for the Baseboard LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IP Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).

When IPv6 addressing is enabled, this field is grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

14. Gateway IP

Option Values: [Entry Field 0.0.0.0, 0.0.0.0 is default]

Help Text:

View/Edit Gateway IP. Press <Enter> to edit.

Comments: This specifies the IPv4 addressing Gateway IP for the Intel®

RMM4 DMN LAN. There is a separate IPv4 Gateway IP field for the Baseboard LAN configuration.

When IPv4 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IP Source determines whether this field is display-only (when Dynamic) or can be edited (when Static).

When IPv6 addressing is enabled, this field is grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

15. IPv6 Source

Option Values: Static

Dynamic

Auto

172 Revision 2.0

BIOS Setup Interface

Help Text:

Select Intel(R) RMM4 IPv6 source: If [Static], IPv6 parameters may be edited. If

[Dynamic], these fields are display-only and IPv6 address is acquired automatically

(DHCP). If [Auto], these fields are display-only and IPv6 address is acquired using

ICMPv6 router / neighbor discovery.

Comments: This specifies the IP Source for IPv6 addressing for the Intel

®

RMM4 DMN LAN configuration. There is a separate IPv6 Source field for the Baseboard

LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is Enabled, the initial value for this field is acquired from the BMC, and its setting determines whether the other Intel

®

RMM4 DMN LAN IPv6 addressing fields are display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

16. IPv6 Address

Option Values:

Help Text:

17. Gateway IPv6

Option Values:

Help Text:

[Entry Field 0000:0000:0000:0000:0000:0000:0000:0000,

0000:0000:0000:0000:0000:0000:0000:0000 is default]

View/Edit IPv6 address. Press <Enter> to edit. IPv6 addresses consist of 8 hexadecimal

4 digit numbers separated by colons.

Comments: This specifies the IPv6 Address for the Intel

®

RMM4 DMN LAN.

There is a separate IPv6 Address field for the Baseboard LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

[Entry Field 0000:0000:0000:0000:0000:0000:0000:0000,

0000:0000:0000:0000:0000:0000:0000:0000 is default]

Revision 2.0 173

BIOS Setup Interface

174

View/Edit Gateway IPv6 address. Press <Enter> to edit. Gateway IPv6 addresses consist of 8 hexadecimal 4 digit numbers separated by colons.

Comments: This specifies the Gateway IPv6 Address for the Intel

®

RMM4

DMN LAN. There is a separate Gateway IPv6 Address field for the Baseboard LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

18. IPv6 Prefix Length

Option Values: [Entry Field 0

– 128, 64 is default]

Help Text:

View/Edit IPv6 Prefix Length from zero to 128 (default 64). Press <Enter> to edit.

Comments: This specifies the IPv6 Prefix Length for the Intel

®

RMM4 DMN

LAN. There is a separate IPv6 Prefix Length field for the Baseboard LAN configuration.

This option is only visible when the IPv6 option is set to Enabled.

When IPv6 addressing is used, the initial value for this field is acquired from the BMC.

The setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or can be edited (when Static).

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

19. BMC DHCP Host Name

Option Values: [Entry Field, 2-63 characters]

Help Text:

View/Edit BMC DHCP host name. Press <Enter> to edit. Host name should start with an alphabetic, remaining can be alphanumeric characters. Host name length may be from 2 to 63 characters.

Comments: This field is active and may be edited whenever at least one of the

IP Source or IPv6 Source options is set to Dynamic. This is the name of the DHCP Host from which dynamically assigned IPv4 or IPv6 addressing parameters are acquired.

The initial value for this field is supplied from the BMC, if there is a DHCP Host available.

The user can edit the existing Host or enter a different DHCP Host Name.

Revision 2.0

BIOS Setup Interface

If none of the IP/IPv6 Source fields is set to Dynamic, then this BMC DHCP Host Name field will be grayed out and inactive.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

20. User ID

Option Values: anonymous root

User3

User4

User5

Help Text:

Select the User ID to configure: User1 (anonymous), User2 (root), and User3/4/5 are supported.

Comments: These 5 User IDs are fixed choices and cannot be changed. The

BMC supports 15 User IDs natively but only the first 5 are supported through this interface.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

21. Privilege

Option Values: Callback

User

Operator

Administrator

Help Text:

View/Select user privilege. User2 (root) privilege is "Administrator" and cannot be changed.

Comments: The level of privilege that is assigned for a User ID affects which functions that user may perform.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

22. User Status

Revision 2.0 175

BIOS Setup Interface

Option Values: Enabled

Disabled

Help Text:

Enable / Disable LAN access for selected user. Also enables/disables SOL, KVM, and media redirection.

Comments: Note that status setting is Disabled by default until set to Enabled.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

23. User Name

Option Values: [Entry Field, 4 - 15 characters]

Help Text:

Press <Enter> to edit User Name. User Name is a string of 4 to 15 alphanumeric characters, and must begin with an alphabetic character. User Name cannot be changed for User1 (anonymous) and User2 (root).

Comments: User Name can only be edited for us ers other than “anonymous” and “root”. Those two User Names may not be changed.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

24. User Password

Option Values: [Popup Entry Field, 0 - 15 characters]

Help Text:

Press <Enter> key to enter password. Maximum length is 15 characters. Any ASCII printable characters can be used: case-sensitive alphabetic, numeric, and special characters.

Note: Password entered will override any previously set password.

Comments: This field will not indicate whether there is a password set already.

There is no display - just press <Enter> for a popup with an entry field to enter a new password. Any new password entered will override the previous password, if there was one.

Back to [BMC LAN Configuration Screen]

— [Server Management Screen] — [Screen

Map]

176 Revision 2.0

BIOS Setup Interface

9.4.2.18 Boot Options Screen (Tab)

The Boot Options screen displays all bootable media encountered during POST, and allows the user to configure the desired order in which boot devices are to be tried.

To access this screen from the Main screen or other toplevel “Tab” screen, press the right or left arrow keys to traverse the tabs at the top of the Setup screen until the Boot Options screen is selected.

The first boot device in the specified Boot Order which is present and is bootable during POST will be used to boot the system, and will continue to be used to reboot the system until the boot device configuration has changed (that is, which boot devices are present), or until the system has been power ed down and booted in a “cold” power-on boot.

Note: USB devices can be “hotplugged” during POST, and will be detected and “beeped”. They will be enumerated and displayed on the USB Configuration Setup screen. However, they may not be enumerated as bootable devices, depending on when in POST they were hotplugged. If they were recognized before the enumeration of bootable devices, they will appear as Boot

Devices if appropriate. If they were recognized after Boot Device enumeration, they will not appear as a bootable device for the Boot Options screen, the Boot Manager screen, or the F6

Boot Menu.

There are two main types of boot order control, Legacy Boot and EFI Optimized boot. These are mutually exclusive

– when EFI Optimized Boot is enabled, Legacy Boot (the default) is disabled.

Within Legacy Boot operation, there are two further methods of ordering boot devices, Dynamic

Boot Order and Static Boot Order.

The default for Boot Order control is Legacy Boot, with Dynamic Boot Order. If all types of bootable devices are installed in the system, then the default Boot Order is as follows:

·

CD/DVD-ROM

·

Floppy Disk Drive

·

Hard Disk Drive

·

PXE Network Device

·

BEV (Boot Entry Vector) Device

·

EFI Shell and EFI Boot paths

In this default Boot Order, a USB device may appear in any of several Device Classes, due to the flexibility of USB connections and USB emulation of various types of devices.

Note: A USB Key (USB Flash Drive) can be formatted to emulate either a Floppy Drive or a

Hard Drive, and will appear in that Boot Device Class. However, although it can be formatted as a CDROM Drive, it will not be detected as such. It will be treated as a Hard Disk and will appear in the list of available Hard Drives.

Revision 2.0 177

BIOS Setup Interface

Figure 36. Boot Option Screen

Screen Field Descriptions:

1. System Boot Timeout

Option Values:

Help Text:

[Entry Field 0

– 65535, 0 is default]

The number of seconds BIOS will pause at the end of POST to allow the user to press the [F2] key for entering the BIOS Setup utility.

Valid values are 0-65535. Zero is the default. A value of 65535 causes the system to go to the Boot Manager menu and wait for user input for every system boot.

Comments: After entering the desired timeout, press the <Enter> key to register that timeout value to the system. These settings are in seconds. The timeout value entered will take effect on the next boot.

178 Revision 2.0

BIOS Setup Interface

This timeout value is independent of the FRB2 setting for BIOS boot failure protection.

The FBR2 countdown will be suspended during the time that the Boot Timeout countdown is active.

Also, if the <Pause> key is pressed during the time that the Boot Timeout is active, the

Boot Timeout countdown will be suspended until the Pause state has been dismissed and normal POST processing has resumed.

Back to [Boot Options Screen]

— Back to [Screen Map]

2. Boot Option #1

3. Boot Option #2

4. Boot Option <#n>

Option Values: <Available Boot Device #n>

Help Text:

Set system boot order by selecting the boot option for this position.

Comments: When the Boot order has been chosen, it will take effect on the next boot. The system will go down the list and boot from the first device on the list which is available and bootable.

This establishes the Boot Order only with respect to the normal boot path. This order has no effect on the Boot Manager selection list or the <F6> BIOS Boot Menu popup, both of which simply list all bootable devices available in the order in which they were detected.

Whether or not a potential Boot Device is in this list has no bearing on the presence or order of Boot Devices shown for Boot Manager or the BIOS Boot Menu.

Back to [Boot Options Screen]

— Back to [Screen Map]

5. CDROM Order

Option Values: <None>

Help Text:

Set the order of the legacy devices in this group.

Comments: Selection only. Select this line and press the <Enter> key to go to the CDROM Order Screen.

This option appears when one or more bootable CDROM drives are available in the system. This includes USB CDROM devices but not USB Keys formatted for CRDOM emulation, which are seen as Hard Disk drives.

Back to [Boot Options Screen]

— Back to [Screen Map]

6. Hard Disk Order

Revision 2.0 179

BIOS Setup Interface

Option Values:

Help Text:

<None>

Set the order of the legacy devices in this group.

Comments: Selection only. Select this line and press the <Enter> key to go to the Hard Disk Order Screen.

This option appears when one or more bootable Hard Disk drives are available in the system. This includes USB Hard Disk devices and USB Keys formatted for Hard Disk or

CRDOM emulation.

Back to [Boot Options Screen]

— Back to [Screen Map]

7. Floppy Order

Option Values: <None>

Help Text:

Set the order of the legacy devices in this group.

Comments: Selection only. Select this line and press the <Enter> key to go to the Floppy Order Screen.

This option appears when one or more bootable Floppy Disk drives are available in the system. This includes USB Floppy Disk devices and USB Keys formatted for Floppy

Disk emulation.

Back to [Boot Options Screen]

— Back to [Screen Map]

8. Network Device Order

Option Values: <None>

Help Text:

Set the order of the legacy devices in this group.

Comments: Selection only. Select this line and press the <Enter> key to go to the Network Device Order Screen.

This option appears when one or more bootable Network Devices are available in the system.

Back to [Boot Options Screen]

— Back to [Screen Map]

9. BEV Device Order

Option Values: <None>

180 Revision 2.0

BIOS Setup Interface

Help Text:

Set the order of the legacy devices in this group.

Comments: Selection only. Select this line and press the <Enter> key to go to the BEV Device Order Screen.

This option appears when one or more bootable BEV Devices are available in the system.

Back to [Boot Options Screen]

— Back to [Screen Map]

10. Add EFI Boot Option

Option Values: <None>

Help Text:

Add a new EFI boot option to the boot order.

Comments: Selection only. Select this line and press the <Enter> key to go to the Add EFI Boot Option Screen.

This option is only displayed if an EFI bootable device is available to the system.

Back to [Boot Options Screen]

— Back to [Screen Map]

11. Delete EFI Boot Option

Option Values: <None>

Help Text:

Remove an EFI boot option from the boot order.

Comments: Selection only. Select this line and press the <Enter> key to go to the Delete EFI Boot Option Screen.

This option is only displayed if an EFI boot path is included in the Boot Order.

Back to [Boot Options Screen]

— Back to [Screen Map]

12. EFI Optimized Boot

Option Values:

Help Text:

Enabled

Disabled

If enabled, the BIOS only loads modules required for booting EFI-aware Operating

Systems.

Revision 2.0 181

BIOS Setup Interface

Comments: non EFI aware OS.

If this option is enabled, the system will not boot successfully to a

Back to [Boot Options Screen]

— Back to [Screen Map]

13. Use Legacy Video for EFI OS

Option Values: Enabled

Disabled

Help Text:

If enabled, the BIOS uses the legacy video ROM instead of the EFI video ROM.

Comments: This option appears only when EFI Optimized Boot is enabled.

Back to [Boot Options Screen]

— Back to [Screen Map]

14. Boot Option Retry

Option Values:

Help Text:

Enabled

Disabled

If enabled, this continually retries non-EFI-based boot options without waiting for user input.

Comments: This option is intended to keep retrying for cases where the boot devices could possibly be slow to initially respond, e.g. if the device were “asleep” and did not wake quickly enough. However, if none of the devices in the Boot Order ever responds, the BIOS will continue to reboot indefinitely.

Back to [Boot Options Screen]

— Back to [Screen Map]

15. USB Boot Priority

Option Values:

Help Text:

Enabled

Disabled

If enabled, newly discovered USB devices are moved to the top of their boot device category.

If disabled, newly discovered USB devices are moved to the bottom of their boot device category.

182 Revision 2.0

BIOS Setup Interface

Comments:

This option enables or disables the “USB Reorder” functionality.

USB Boot Priority, if enabled, is intended for the case where a user wants to be able to plug in a USB device and immediately boot to it, for example in case of a maintenance or System Administration operation. If a User Password is installed, USB Boot Priority action is suspended when a User Password is installed.

Back to [Boot Options Screen]

— Back to [Screen Map]

16. Static Boot Order

Option Values: Enabled

Disabled

Help Text:

[Disabled] - Devices removed from the system are deleted from Boot Order Tables.

[Enabled] - Devices removed have positions in Boot Order Tables retained for later reinsertion.

Comments:

When the option changes to “Enabled” from “Disabled”, it will enable Static Boot Order (SBO) from the next boot onward, and also the current Boot

Order will be stored as the SBO template.

When the option changes from “Enabled” to “Disabled”, this will disable SBO and the

SBO template will be cleared.

Otherwise it will retain the current Enabled/Disabled state.

Back to [Boot Options Screen]

— Back to [Screen Map]

17. Reset Static Boot Order

Option Values:

Help Text:

Yes

No Action

[Yes] Take snapshot of current boot order to save as Static Boot Order Template.

Comments: This option will allow you to save the Boot Order list as the Static

Boot Order template without disabling and re-enabling the Static Boot Order option.

Select Yes to snapshot the current Boot Options list into the Static Boot Options list on the next boot. After saving Static Boot Options list, this option will change back to

NoAction automatically.

This option is available only when the Static Boot Order option is Enabled. Otherwise it will grayed out and unavailable.

Revision 2.0 183

BIOS Setup Interface

Back to [Boot Options Screen]

— Back to [Screen Map]

9.4.2.19 CDROM Order

The CDROM Order screen allows the user to control the order in which BIOS attempts to boot from the CDROM drives installed in the system. This screen is only available when there is at least one CDROM device available in the system configuration.

Note: A USB attached CDROM device will appear in this section. However, a USB Key formatted as a CRDOM device will not

– it will be detected as a Hard Disk device and will be included in the Hard Disk Order Screen.

To access this screen from the Main screen, select Boot Options > CDROM Order. To move to another screen, press the <Esc> key to return to the Boot Options screen, then select the desired screen.

Figure 37. CDROM Order Screen

Screen Field Descriptions:

1. CDROM #1

2. CDROM #2

Option Values:

Help Text:

<Available CDROM devices>

Set system boot order by selecting the boot option for this position.

Comments: Choose the order of booting among CDROM devices by choosing which available CDROM device should be in each position in the order.

Back to [CDROM Order Screen]

— [Boot Options Screen] — [Screen Map]

9.4.2.20 Hard Disk Order

The Hard Disk Order screen allows the user to control the order in which BIOS attempts to boot from the hard disk drives installed in the system. This screen is only available when there is at least one hard disk device available in the system configuration. Note that a USB attached Hard

Disk drive or a USB Key device formatted as a hard disk will appear in this section.

184 Revision 2.0

BIOS Setup Interface

To access this screen from the Main screen, select Boot Options > Hard Disk Order. To move to another screen, press the <Esc> key to return to the Boot Options screen, then select the desired screen.

Figure 38. Hard Disk Order Screen

Screen Field Descriptions:

1. Hard Disk #1

2. Hard Disk #2

Option Values:

Help Text:

<Available Hard Disk devices>

Set system boot order by selecting the boot option for this position.

Comments: Choose the order of booting among Hard Disk devices by choosing which available Hard Disk device should be in each position in the order.

Back to [Hard Disk Order Screen]

— [Boot Options Screen] — [Screen Map]

9.4.2.21 Floppy Order

The Floppy Order screen allows the user to control the order in which BIOS attempts to boot from the Floppy Disk drives installed in the system. This screen is only available when there is at least one Floppy Disk (diskette) device available in the system configuration. Note that a USB attached diskette drive or a USB Key device formatted as a diskette drive will appear in this section.

To access this screen from the Main screen, select Boot Options > Floppy Order. To move to another screen, press the <Esc> key to return to the Boot Options screen, then select the desired screen.

Revision 2.0 185

BIOS Setup Interface

Figure 39. Floppy Order Screen

Screen Field Descriptions:

1. Floppy Disk #1

2. Floppy Disk #2

Option Values: <Available Floppy Disk devices>

Help Text:

Set system boot order by selecting the boot option for this position.

Comments: Choose the order of booting among Floppy Disk devices by choosing which available Floppy Disk device should be in each position in the order.

Back to [Floppy Order Screen]

— [Boot Options Screen] — [Screen Map]

9.4.2.22 Network Device Order

The Network Device Order screen allows the user to control the order in which BIOS attempts to boot from the network bootable devices installed in the system. This screen is only available when there is at least one network bootable device available in the system configuration.

To access this screen from the Main screen, select Boot Options > Network Device Order. To move to another screen, press the <Esc> key to return to the Boot Options screen, then select the desired screen.

Screen Field Descriptions:

Figure 40. Network Device Order Screen

186 Revision 2.0

BIOS Setup Interface

1. Network Device #1

2. Network Device #2

Option Values:

Help Text:

<Available Network Devices>

Set system boot order by selecting the boot option for this position.

Comments: Choose the order of booting among Network Devices by choosing which available Network Device should be in each position in the order.

Back to [Network Device Order Screen]

— [Boot Options Screen] — [Screen Map]

9.4.2.23 BEV Device Order

The BEV Device Order screen allows the user to control the order in which BIOS attempts to boot from the BEV Devices installed in the system. This screen is only available when there is at least one BEV device available in the system configuration.

To access this screen from the Main screen, select Boot Options > BEV Device Order. To move to another screen, press the <Esc> key to return to the Boot Options screen, then select the desired screen.

Figure 41. BEV Device Order Screen

Screen Field Descriptions:

1. BEV Device #1

2. BEV Device #2

Option Values: <Available BEV Devices>

Help Text:

Set system boot order by selecting the boot option for this position.

Comments: Choose the order of booting among BEV Devices by choosing which available BEV Device should be in each position in the order.

Back to [BEV Device Order Screen]

— [Boot Options Screen] — [Screen Map]

Revision 2.0 187

BIOS Setup Interface

9.4.2.24 Add EFI Boot Option

The Add EFI Boot Option screen allows the user to add an EFI boot option to the boot order.

This screen is only available when there is at least one EFI bootable device present in the system configuration. The “Internal EFI Shell” Boot Option is permanent and cannot be added or deleted.

To access this screen from the Main screen, select Boot Options > Add EFI Boot Option. To move to another screen, press the <Esc> key to return to the Boot Options screen, then select the desired screen.

Figure 42. Add EFI Boot Option Screen

Screen Field Descriptions:

1. Add boot option label

Option Values:

Help Text:

[Enter label]

Create the label for the new boot option.

Comments: This label becomes an abbreviation for this Boot Path.

Back to [Add EFI Boot Option Screen]

— [Boot Options Screen] — [Screen Map]

2. Select File system

Option Values: <Available Filesystems>

Help Text:

Select one filesystem from this list.

Comments: Choose the filesystem on which this boot path resides.

Back to [Add EFI Boot Option Screen]

— [Boot Options Screen] — [Screen Map]

3. Path for boot option

188 Revision 2.0

BIOS Setup Interface

Option Values:

Help Text:

[Enter Boot Path]

Enter the path to the boot option in the format \path\filename.efi.

Comments: This will be the Boot Path, residing on the filesystem chosen, which will enter into the Boot Order with the Label entered above.

Back to [Add EFI Boot Option Screen]

— [Boot Options Screen] — [Screen Map]

4. Save

Option Values:

Help Text:

Save the boot option.

<None>

Comments:

Order.

Selection only. This will save the new Boot Option into the Boot

Back to [Add EFI Boot Option Screen]

— [Boot Options Screen] — [Screen Map]

9.4.2.25 Delete EFI Boot Option

The Delete EFI Boot Option screen allows the user to remove an EFI boot option from the boot order. The “Internal EFI Shell” Boot Option will not be listed, since it is permanent and cannot be added or deleted.

To access this screen from the Main screen, select Boot Options > Delete EFI Boot Option. To move to another screen, press the <Esc> key to return to the Boot Options screen, then select the desired screen.

Screen Field Descriptions:

1. Delete Boot Option

Option Values:

Help Text:

Figure 43. Delete EFI Boot Option Screen

<Available EFI Boot Options>

Revision 2.0 189

BIOS Setup Interface

Select one to delete.

Comments: This will not allow a user to delete the EFI Shell.

Back to [Delete EFI Boot Option Screen]

— [Boot Options Screen] — [Screen Map]

9.4.2.26 Boot Manager Screen (Tab)

The Boot Manager screen allows the user to view a list of devices available for booting, and to select a boot device for immediately booting the system. There is no predetermined order for listing bootable devices. They are simply listed in order of discovery.

Regardless of whether any other bootable devices are available, the “Internal EFI Shell” will always be available.

Note: This list is not in order according to the system Boot Option order. Reordering Boot

Devices or even removing them from the Boot Order completely has no effect on the Boot

Manager.

To access this screen from the Main screen or other toplevel “Tab” screen, press the right or left arrow keys to traverse the tabs at the top of the Setup screen until the Boot Manager screen is selected.

Figure 44. Boot Manager Screen

Screen Field Descriptions:

1. Launch EFI Shell

Option Values:

Help Text:

<None>

Select this option to boot now.

Note: This list is not the system boot option order. Use the Boot Options menu to view and configure the system boot option order.

Comments: The EFI Shell will always be present in the list of bootable devices.

Back to [Boot Manager Screen]

— [Screen Map]

190 Revision 2.0

BIOS Setup Interface

2. <Boot Device #1>

3. <Boot Device #2>

4. <Boot Device #n>

Option Values:

<None>

Help Text:

Select this option to boot now.

Note: This list is not the system boot option order. Use the Boot Options menu to view and configure the system boot option order.

Comments: These are names of bootable devices discovered in the system.

The system user can choose any of them from which to initiate a one-time boot

– that is, booting from any device in this list will not permanently affect the defined system Boot

Order.

These bootable devices are not displayed in any specified order, particularly not in the system Boot Order established by the Boot Options screen. This is just a list of bootable devices in the order in which they were enumerated.

Back to [Boot Manager Screen]

— [Screen Map]

9.4.2.27 Error Manager Screen (Tab)

The Error Manager screen displays any POST Error Codes encountered during BIOS POST, along with an explanation of the meaning of the Error Code in the form of a Help Text. This is an

Information Only screen.

To access this screen from the Main screen or other toplevel “Tab” screen, press the right or left arrow keys to traverse the tabs at the top of the Setup screen until the Error Manager screen is selected.

Figure 45. Error Manager Screen

Screen Field Descriptions:

1. ERROR CODE

Option Values:

Revision 2.0

<POST Error Code>

191

BIOS Setup Interface

Help Text: <N/A>

Comments: This is a POST Error Code

– a BIOS-originated error that occurred during POST initialization.

Back to [Error Manager Screen]

— [Screen Map]

2. SEVERITY

Option Values: Minor

Major

Fatal

<N/A> Help Text:

Comments: Each POST Error Code has a Severity associated with it.

Back to [Error Manager Screen]

— [Screen Map]

3. INSTANCE

Option Values:

<N/A>

<Depends on error code>

Help Text:

Comments: Where applicable, this field shows a value indicating which one of a group of components was responsible for generating the POST Error Code that is being reported.

Back to [Error Manager Screen]

— [Screen Map]

4. DESCRIPTION

Option Values: <N/A>

<Description of POST Error Code> Help Text:

Comments: This is a description of the meaning of the POST Error Code that is being reported. This text actually appears in the screen space that is usually reserved for “Help” messages.

Back to [Error Manager Screen]

— [Screen Map]

9.4.2.28 Save & Exit Screen (Tab)

The Save &Exit screen allows the user to choose whether to save or discard the configuration changes made on other Setup screens. It also allows the user to restore the BIOS settings to the factory defaults or to save or restore them to a set of user-defined default values. If Load

Default Values is selected, the factory default settings (noted in bold in the Setup screen images)

192 Revision 2.0

BIOS Setup Interface are applied. If Load User Default Values is selected, the system is restored to previously saved

User Default Values.

To access this screen from the Main screen or other toplevel “Tab” screen, press the right or left arrow keys to traverse the tabs at the top of the Setup screen until the Exit screen is selected.

Note: There is a Legal Disclaimer footnote at the bottom of the Save & Exit screen:

*Certain brands and names may be claimed as the property of others.

This is reference to any instance in the Setup screens where names belonging to other companies may appear. For example

“LSI*” appears in Setup in the context of Mass Storage

RAID options.

Figure 46. Save & Exit Screen

Screen Field Descriptions:

1. Save Changes and Exit

Option Values: <None>

Help Text:

Exit BIOS Setup Utility after saving changes. The system will reboot if required.

The [F10] key can also be used.

Comments: Selection only. Select this line and press the <Enter> key to exit

Setup with any changes in BIOS settings saved. If there have been no changes made in the settings, the BIOS will resume executing POST.

Revision 2.0 193

BIOS Setup Interface

If changes have been made in BIOS settings, a confirmation pop-up will appear. If the

“Save Changes & Exit” action is positively confirmed, any persistent changes will applied and saved to the BIOS settings in NVRAM storage, then the system will reboot if necessary (which is normally the case). If the “Save Changes & Exit” action is not confirmed, BIOS will resume executing Setup.

The <F10 > function key may also be used from anyplace in Setup to initiate a “Save

Changes & Exit” action.

Back to [Save & Exit Screen]

— [Screen Map]

2. Discard Changes and Exit

Option Values: <None>

Help Text:

Exit BIOS Setup Utility without saving changes.

The [Esc] key can also be used.

Comments: Selection only. Select this line and press the <Enter> key to exit

Setup without saving any changes in BIOS settings. If there have been no changes made in the settings, the BIOS will resume executing POST.

If changes have been made in BIOS settings, a confirmation pop-up will appear. If the

“Discard Changes & Exit” action is positively confirmed, all pending changes will be discarded and BIOS will resume executing POST. If the “Discard Changes & Exit” action is not confirmed, BIOS will resume executing Setup without discarding any changes.

The <Esc > key may al so be used in Setup to initiate a “Discard Changes & Exit” action.

Back to [Save & Exit Screen]

— [Screen Map]

3. Save Changes

Option Values: <None>

Help Text:

Save Changes made so far to any of the setup options.

Comments: Selection only. Select this line and press the <Enter> key to save any pending changes in BIOS settings. If there have been no changes made in the settings,

Also, the user should be aware that most changes require a reboot to become active. If changes have been made and saved, without exiting Setup, the system should be rebooted later even if no additional changes are made.

Back to [Save & Exit Screen]

— [Screen Map]

194 Revision 2.0

BIOS Setup Interface

4. Discard Changes

Option Values: <None>

Help Text:

Discard Changes made so far to any of the setup options.

Comments: Selection only. Select this line and press the <Enter> key to discard any pending unsaved changes in BIOS settings. If there have been no changes made in the settings, the BIOS will resume executing POST.

If changes have been made in BIOS settings and not yet saved, a confirmation pop-up will appear. If the “Discard Changes” action is positively confirmed, all pending changes will be discarded and BIOS will resume executing POST. If the “Discard Changes” action is not confirmed, BIOS will resume executing Setup without discarding pending changes.

Back to [Save & Exit Screen]

— [Screen Map]

5. Load Default Values

Option Values: <None>

Help Text:

Load Defaults Values for all the setup options.

Comments: Selection only. Select this line and press the <Enter> key to load default values for all BIOS settings. These are the initial factory settings (“failsafe” settings) for all BIOS parameters.

There will be a confirmation popup to verify that the user really meant to take this action.

After initializing all BIOS settings to default values, the BIOS will resume executing

Setup, so the user may made additional changes in the BIOS settings if necessary (for example, Boot Order) before doing a “Save Changes and Exit” with a reboot to make the default settings take effect, including any changes made after loading the defaults.

The <F9> function key may also be used from anyplace in Setup to initiate a “Load

Default Values” action.

Back to [Save & Exit Screen]

— [Screen Map]

6. Save as User Default Values

Option Values: <None>

Help Text:

Save the changes made so far as User Default Values.

Revision 2.0 195

BIOS Setup Interface

Comments: Selection only. Select this line and press the <Enter> key to save the current state of the settings for all BIOS parameters as a customized set of “User

Default Values”.

These are a user-determined set of BIOS default settings that can be used as an alternative instead of the initial factory settings (“failsafe” settings) for all BIOS parameters.

By changing the BIOS settings to values that the user prefers to have for defaults, and then using this operation to save them as “User Default Values”, that version of BIOS settings can be restored at any time by using the following “Load User Default Values” operation.

There will be a confirmation popup to verify that the user really intended to take this action.

Loading the “factory default” values with F9 or the “Load Default Values” – or by any other means

– does not affect the User Default Values. They remain set to whatever values they were saved as.

Back to [Save & Exit Screen]

— [Screen Map]

7. Load User Default Values

Option Values: <None>

Help Text:

Load the User Default Values to all the setup options.

Comments: Selection only. Select this line and press the <Enter> key to load

User Default Values for all BIOS settings. These are user-customized BIOS default settings for all BIOS parameters, previously established by doing a “Save User Defaults” action (see above).

There will be a confirmation popup to verify that the user really intended to take this action.

Back to [Save & Exit Screen]

— [Screen Map]

9.5 BIOS Update Capability

The actual BIOS code that runs during POST is stored in Flash Memory on the baseboard. In general a user needs to interact with that code very little, other than when there is a BIOS problem to fix or new BIOS features or capabilities become available.

In order to bring those BIOS fixes or new features into the system, it is necessary to install updated BIOS in Flash Memory, replacing the current BIOS image. The user can do this either as a standalone process with a utility program running under the UEFI shell, or with an application program running under the OS.

196 Revision 2.0

BIOS Setup Interface

The BIOS update is done using a “capsule” file which contains all relevant BIOS components.

This capsule omits the NVRAM Firmware Volume, which retains its existing contents through the BIOS Update. There is a single BIOS capsule file for a given BIOS Release for updating the

BIOS on all of the boards in the S1200RP Server Board Family.

It is also possible to completely reprogram the Flash Memory component using an EPROM

Programmer and a binary BIOS image but this requires removing the Flash chip and is generally only done in a Development environment with a socketed Flash part. That is not discussed in this document.

9.5.1 Standalone BIOS Flash Update

The “IFlash32” BIOS Update Utility is a UEFI Shell application program used for updating the system BIOS using the capsule file from a BIOS release. This tool can also be used to update the ME but that is not discussed in this document (refer to ME Release Notes for update instructions).

There is an IFlash32 version available for WinPE* environments. This version requires that

“Plug & Play BMC Detection” must be enabled in the Server Management tab in Setup (see

Figure 32), and drivers must be installed. Refer to the IFlash32 program Release Notes for

information on this.

The following procedure shows the steps necessary to update the BIOS using IFlash32 running under the UEFI Shell. The assumption is that the user has obtained a BIOS release in compressed (“Zip”) format, typically by downloading it from the Intel Support Website.

This is the general procedure for the UEFI BIOS Update

– the BIOS Release Notes will include the most up-to-date procedure.

1. Unzip the compressed zip file on any Windows system and copy the UEFI folder (two required files: iflash32.efi and ipmi.efi) to any external medium, typically a USB Flash

Drive (USB Key).

2. Copy the new capsule file to be updated (it has a file extension of

.cap”) to the same folder as iflash32.efi.

3. Boot to the EFI Shell on the system to be updated, and connect the external medium with the capsule file and IFlash32 to it.

4. Go to the directory where iflash32.efi is present on the external medium.

5. Run the command iflash32 –u -ni [CapsuleFileName.cap]

where

-u = update the System BIOS

-ni = update will be in non-interactive mode

[CapsuleFileName.cap] = replace with name of BIOS capsule file

6. At the end of the flash update, if the update is successful, a message will be displayed:

BIOS has been updated successfully.

Revision 2.0 197

BIOS Setup Interface

If the flash update fails for reasons of security compliance, a different message will be displayed:

security compliance check. Please refer to BIOS Release Notes for details.

7. In order to properly complete the BIOS Update process, the system must perform a shutdown

– DC power-off – then DC power-on and boot successfully to the EFI Shell or an OS environment.

In order to restore customer-determined BIOS setting defaults, another procedure is required after the BIOS update is successful:

1. Boot to the EFI Shell on the system just updated, and keep the external media with

IFlash32 to it.

2. Go to the directory where iflash32.efi is present on the external medium.

3. Run the command iflash32 –rd “[AdminPassword]

” where

-rd = restore customer-determined BIOS setting defaults

[AdminPassword] = BIOS Administer Password only if BIOS Administer Password was set.

4. Reset the system and the instruction returns success.

If there is a power loss during the IFlash32 BIOS Update:

Try rebooting to the EFI Shell. If that is successful, restart the BIOS Update.

If the boot to the EFI Shell fails, perform a Recovery Boot (see Section 9.6) using the

Recovery capsule from the previously installed BIOS, that is, the BIOS version before the update.

Refer to the BIOS Release Notes and the IFlash32 program Release Notes for the most complete and accurate information, as well as additional information on the WinPE* version of

IFlash32.

9.5.2 OS-Running BIOS Flash Update

The

“One-Boot Flash Update” (OFU) Firmware Update Utility is an application program which can update the system BIOS while the system is in an “OS Running” state, so there is no need to take the system out of service to perform a BIOS update.

The OFU utility can actually update the ME, BMC, and SDR firmware as well as the BIOS. OFU is supported for both Windows and Linux (certain versions). It uses the BIOS capsule file for the

BIOS update.

This utility requires that

“Plug & Play BMC Detection” must be enabled in the Server

Management tab in Setup (see Figure 32), and drivers must be installed depending on OS

version. Refer to the One-Boot Flash Update program Release Notes for information on how to use it in different OS environments.

198 Revision 2.0

BIOS Setup Interface

9.5.3 BIOS Backup Flash Update

The BIOS is also supported for updating the backup BIOS regions by update utility issues

“UpdateBackupBios” command. After the BIOS receives request from utility, the backup BIOS update will be completed in next normal boot. It will show message "DO NOT REMOVE

POWER! Now updating Backup BIOS region......" in update beginning, after backup update completed, will show “Done”.

This is the general procedure for the UEFI backup BIOS Update

– the BIOS Release Notes will include the most up-to-date procedure.

1. Unzip the compressed zip file on any Windows system and copy the UEFI folder (two required files: iflash32.efi and ipmi.efi) to any external medium, typically a USB Flash

Drive (USB Key).

2.

Copy the new capsule file to be updated (it has a file extension of “.cap”) to the same folder as iflash32.efi.

3. Boot to the EFI Shell on the system to be updated, and connect the external medium with the capsule file and IFlash32 to it.

4. Go to the directory where iflash32.efi is present on the external medium.

5. Run the command iflash32 –u -ni [CapsuleFileName.cap] UpdateBackupBios where

-u = update the System BIOS

-ni = update will be in non-interactive mode

[CapsuleFileName.cap] = replace with name of BIOS capsule file

UpdateBackupBios = update the system backup BIOS

6. It will update primary BIOS with processed capsule. If the primary update is successful, then restart the system to complete backup BIOS update, and a message will be displayed:

"Primary Update completed, Backup BIOS update will be completed

in next boot."

9.6 BIOS Recovery

If a system is completely unable to boot successfully to an OS, hangs during POST, or even hangs and fails to start executing POST, it may be necessary to perform a BIOS Recovery procedure, which can replace a defective copy of the BIOS code.

This is intended to be a “last resort” method, and should not be used unless necessary.

Basically, this procedure involves opening the chassis, setting the BIOS Recovery jumper, and then following the instructions detailed in the current BIOS Release Notes.

Revision 2.0 199

BIOS Setup Interface

The Recovery procedure is included here for general reference. However, if in conflict, the instructions in the BIOS Release Notes are the definitive version.

A BIOS recovery can be accomplished with images on backup flash blocks. The Recovery medium in USB Flash Drive must contain the following files in its root directory:

UEFI iFlash32 (including IFlash32.efi and ipmi.efi)

*Rec.CAP

(“*” is a prefix depending on the BIOS Release number)

Startup.nsh (edited as necessary to use the proper *Rec.CAP file)

The *Rec.CAP files should be from the BIOS version which is currently installed on the system.

A mismatch between the Recovery files and the installed BIOS can cause unexpected failures in Recovery.

The BIOS starts the recovery process by first loading and booting to the recovery images from backup flash blocks. This process takes place before any video or console is available. Once the system boots to this recovery image file, it will boot automatically into EFI Shell to invoke the

Startup.nsh script and start the flash update application (IFlash32.efi). IFlash32.efi requires the supporting BIOS Capsule image file (*Rec.CAP).

After the update is complete, there will b e a message displayed stating that the “BIOS has been updated successfully" indicating the recovery process is finished. The User should then switch the recovery jumper back to normal operation and restart the system by performing a power cycle.

Step by step, this process goes as follows:

1. Power off the system. Removing AC power is not necessary but may be advisable due to safety considerations, or if a riser or other hardware must be moved for access to the

BIOS Recovery jumper.

2. Open the chassis and move the BIOS Recovery jumper (marked BIOS RCVR) to its

“Recovery” position on pins 2-3. Details regarding the jumper location can be obtained from the Technical Product Specification for the baseboard in the system. Restore any hardware to its correct position and close the chassis.

3. Insert recovery media (prepared previously as described above).

4. Power on the system. A beep code of 2 beeps should sound, indicating the start of

Recovery.

5. If the Recovery Boot process fails prior to initializing video, there should be a 4-beep code and the system should halt with a Recovery Progress Code displayed in the

Diagnostic LEDs.

6. The BIOS POST screen will appear displaying the progress, and the system will automatically boot to the EFI SHELL.

7. The Startup.nsh file will execute automatically, and will initiate the flash update

(IFlash32.efi) with the new capsule file (*Rec.CAP). The regular IFlash success message will be displayed at the end of the process, once the flash update succeeds.

200 Revision 2.0

BIOS Setup Interface

8. Power off the system. Again, removing AC power is not necessary but may be advisable due to safety considerations, or if a riser or other hardware must be moved for access to the BIOS Recovery jumper.

9. Open the chassis, move hardware if necessary, and restore the recovery jumper position to "normal operation" pins 1-2. Replace any hardware moved, and close the chassis.

10. Remove Recovery medium.

11. Replug AC cords if removed, and power on the system.

12. Do NOT interrupt the BIOS POST during the first boot.

13. Boot the system into Setup. The Recovery Boot process will reset BIOS settings to default values.

14. Go to the Setup Main tab (see Figure 20), and set the System Date and System Time to

the correct current settings. Make any other changes that are required in Setup

– for example, Boot Order.

Again, before starting to perform a Recovery Boot, be sure to check the BIOS Release Notes and verify the Recovery procedure shown in the Release Notes.

Revision 2.0 201

Jumper Blocks

10. Jumper Blocks

The server board includes several 3-pin jumper blocks which are used to as part of a process to restore a board function back to a normal functional state. The following diagram and sections identify the location of each jumper block and provides a description of their use.

The following symbol identifies Pin 1 on each jumper block on the silkscreen:

Figure 47. Jumper Blocks (J2K6, J2K8, J2K9, J3K2, J3K6)

Note:

1. For safety purposes, the power cord should be disconnected from a system before removing any system components or moving any of the on-board jumper blocks.

2. System Update and Recovery files are included in the System Update Packages (SUP) posted to Intel’s website.

202 Revision 2.0

Jumper Blocks

Table 58. Server Board Jumpers (J2K6, J2K8, J2K9, J3K2, J3K6)

Jumper Name

J2K6: BIOS

Default

J2K8: BIOS

Recovery

J2K9:

Password

Clear

J3K2: ME

Force Update

J3K6: BMC

Force Update

Pins System Results

1-2 These pins should have a jumper in place for normal system operation. (Default)

2-3 If pins 2-3 are jumpered with AC power plugged in, the CMOS settings clear in 5 seconds.

Pins 2-3 should not be jumpered for normal system operation.

1-2 Pins 1-2 should be jumpered for normal system operation. (Default)

2-3 The main system BIOS does not boot with pins 2-3 jumpered. The system only boots from

EFI-bootable recovery media with a recovery BIOS image present.

1-2 These pins should have a jumper in place for normal system operation.

2-3 To clear administrator and user passwords, power on the system with pins 2-3 connected.

The administrator and user passwords clear in 5-10 seconds after power on. Pins 2-3 should not be connected for normal system operation.

1-2 ME Firmware Force Update Mode

– Disabled (Default)

2-3

ME Firmware Force Update Mode

– Enabled

1-2

BMC Firmware Force Update Mode

– Disabled (Default)

2-3 BMC Firmware Force Update Mode

– Enabled

10.1 BIOS Default Jumper Block

1. This jumper resets BIOS Setup options to their default factory settings.

2. Power down the server and unplug the power cords.

3. Open the chassis and remove the Riser #2 assembly.

4. Move BIOS DFLT jumper from the default (pins 1 and 2) position to the Set BIOS

Defaults position (pins 2 and 3).

5. Wait 5 seconds then move the jumper back to the default position of pins 1 and 2.

6. Install riser card assembly.

7. Install Power Cords.

8. Power on system.

Note: BIOS Error Manager should report a 5220 error code (BIOS Settings reset to default settings).

10.2 BIOS Recovery Jumper

When the BIOS Recovery jumper block is moved from its default pin position, the system will boot into a BIOS Recovery Mode. It is used when the system BIOS has become corrupted and is non-functional, requiring a new BIOS image to be loaded on to the server board.

Note: The BIOS Recovery jumper is ONLY used to re-install a BIOS image in the event the

BIOS has become corrupted. This jumper is NOT used when the BIOS is operating normally and you need to update the BIOS from one version to another.

The following steps demonstrate the BIOS recovery process:

Revision 2.0 203

Jumper Blocks

1. After downloading the latest System Update Package (SUP) from the Intel

®

website, copy the following files to the root directory of a USB media device:

-

-

-

-

-

IPMI.EFI

IFlash32.EFI

RML.ROM

####REC.CAP (where #### = BIOS revision number)

STARTUP.NSH

2. Power OFF the system

3. Locate the BIOS Recovery Jumper on the server board and move the jumper block from pins 1-2 (default) to pins 2-3 (recovery setting)

4. Insert the recovery media into a USB port

5. Power ON the system

6. The system will automatically boot into the embedded EFI Shell

7. The STARTUP.NSH file automatically executes and initiates the flash update. When complete, the IFlash utility will display a message

8. Power OFF the system and return the BIOS Recovery jumper to its default position

9. Power ON the system

10. Do *NOT* interrupt the BIOS POST during the first boot.

11. Configure desired BIOS settings

10.3 Password Clear Jumper Block

This jumper causes both the User password and the Administrator password to be cleared if they were set. The operator should be aware that this creates a security gap until passwords have been installed again through the BIOS Setup utility. This is the only method by which the

Administrator and User passwords can be cleared unconditionally. Other than this jumper, passwords can only be set or cleared by changing them explicitly in BIOS Setup or by similar means. No method of resetting BIOS configuration settings to default values will affect either the

Administrator or User passwords.

1. Power down the server and unplug the power cords.

2. Open the chassis and remove the Riser #2 assembly.

3. Move jumper from the default (pins 1 and 2) operating position to the password clear position (pins 2 and 3).

4. Close the server chassis and reattach the power cords.

5. Power up the server and wait until POST completes.

204 Revision 2.0

Jumper Blocks

Note: BIOS Error Manager should report a 5224 and 5221 error codes (Password clear jumper is set and Passwords cleared by jumper).

6. Power down the server and unplug the power cords.

7. Open the chassis, remove the Riser #2 assembly, and move the jumper back to the default position (covering pins 1 and 2).

8. Reinstall the Riser #2 assembly.

9. Close the server chassis and reattach the power cords.

10. Power up the server.

10.4 Management Engine (ME) Firmware Force Update Jumper Block

When the ME Firmware Force Update jumper is moved from its default position, the ME is forced to operate in a reduced minimal operating capacity. This jumper should only be used if the ME firmware has gotten corrupted and requires re-installation. The following procedure should be followed.

Note: System Update and Recovery files are included in the System Update Packages (SUP) posted to Intel’s website.

1. Turn off the system and remove power cords.

2. Remove Riser Card Assembly #2.

3. Move the ME FRC UPD Jumper from the default (pins 1 and 2) operating position to the

Force Update position (pins 2 and 3).

4. Re-attach system power cords.

5. Power on the system.

Note: System Fans will boost and the BIOS Error Manager should report an 83A0 error code (ME in recovery mode).

6.

Boot to the EFI shell and update the ME firmware using the “MEComplete####.cap” file

(where #### = ME revision number) using the following command: iflash32 /u /ni

MEComplete####.cap.

7. When update has successfully completed, power off system.

8. Remove AC power cords.

9. Move ME FRC UPD jumper back to the default position.

Note: If the ME FRC UPD jumper is moved with AC power applied, the ME will not operate properly. The system will need have the AC power cords removed, wait for at least 10 seconds and then reinstalled to ensure proper operation.

Revision 2.0 205

Jumper Blocks

10. Install PCI Riser.

11. Install AC power cords.

12. Power on system.

10.5 BMC Force Update Jumper Block

The BMC Force Update jumper is used to put the BMC in Boot Recovery mode for a low-level update.

It is used when the BMC has become corrupted and is non-functional, requiring a new BMC image to be loaded on to the server board.

1. Turn off the system and remove power cords.

2. Move the BMC FRC UPDT Jumper from the default (pins 1 and 2) operating position to the Force Update position (pins 2 and 3).

3. Re-attach system power cords.

4. Power on the system.

Note: System Fans will boost and the BIOS Error Manager should report an 84F3 error code (Baseboard Management Controller in update mode).

5. Boot to the EFI shell and update the BMC firmware using BMC####.NSH (where #### is the version number of the BMC).

6. When update has successfully completed, power off system.

7. Remove AC power cords.

8. Move BMC FRC UPDT jumper back to the default position.

9. Install AC power cords.

10. Power on system.

11. Boot to the EFI shell and update the FRU and SDR data using FRUSDR####.nsh

(where #### is the version number of the FRUSDR package).

12. Reboot the system.

13. Configure desired BMC configuration settings.

206 Revision 2.0

11. Intel

®

The server board includes several on-board LED indicators to aid troubleshooting various board level faults. The following figure shows the location for each:

Revision 2.0

Figure 48. On-Board LED Placement

207

11.1 System ID LED

The server board includes a blue system ID LED which is used to visually identify a specific server installed among many other similar servers. There are two options available for illuminating the System ID LED.

1. The front panel ID LED Button is pushed, which causes the LED to illuminate to a solid on state until the button is pushed again.

2. An IPMI Chassis Identify command is remotely entered, which causes the LED to blink.

The System ID LED on the server board is tied directly to the System ID LED on system front panel if present.

11.2 System Status LED

The server board includes a bi-color System Status LED. The System Status LED on the server board is tied directly to the System Status LED on the front panel (if present). This LED indicates the current health of the server. Possible LED states include solid green, blinking green, blinking amber, and solid amber.

When the server is powered down (transitions to the DC-off state or S5), the BMC is still on standby power and retains the sensor and front panel status LED state established before the power-down event.

When AC power is first applied to the system, the status LED turns solid amber and then immediately changes to blinking green to indicate that the BMC is booting. If the BMC boot process completes with no errors, the status LED will change to solid green.

Table 59. System Status LED State Definitions

Color

Off

Green

Green

State

System is not operating

Solid on

~1 Hz blink

Criticality

Not ready

Ok

Degraded - system is operating in a degraded state although still functional, or system is operating in a redundant state but with an impending failure warning

Description

1. System is powered off (AC and/or DC).

2. System is in EuP Lot6 Off Mode.

3. System is in S5 Soft-Off State.

4. System is in S4 Hibernate Sleep State.

Indicates that the System is running (in S0 State) and its status is

‘Healthy’. The system is not exhibiting any errors. AC power is present and BMC has booted and manageability functionality is up and running.

System degraded:

Redundancy loss, such as power-supply or fan. Applies only if the associated platform sub-system has redundancy capabilities.

Fan warning or failure when the number of fully operational fans is more than minimum number needed to cool the system.

Non-critical threshold crossed

– Temperature (including HSBP temp), voltage, input power to power supply, output current for main power rail from power supply and Processor Thermal Control (Therm Ctrl) sensors.

Power supply predictive failure occurred while redundant power supply configuration was present.

Unable to use all of the installed memory (one or more DIMMs

208 Revision 2.0

Color

Amber ~1 Hz blink

Amber

State

Solid on

Criticality

Non-critical -

System is operating in a degraded state with an impending failure warning, although still functioning

Critical, nonrecoverable

System is halted

Description failed/disabled but functional memory remains available)

Correctable Errors over a threshold and migrating to a spare DIMM

(memory sparing). This indicates that the user no longer has spared

DIMMs indicating a redundancy lost condition. Corresponding DIMM

LED lit.

Uncorrectable memory error has occurred in memory Mirroring Mode, causing Loss of Redundancy.

Correctable memory error threshold has been reached for a failing

DDR3 DIMM when the system is operating in fully redundant RAS

Mirroring Mode.

Battery failure.

BMC executing in uBoot. (Indicated by Chassis ID blinking at Blinking at 3Hz). System in degraded state (no manageability). BMC uBoot is running but has not transferred control to BMC Linux*. Server will be in this state 6-8 seconds after BMC reset while it pulls the Linux* image into flash

BMC booting Linux*. (Indicated by Chassis ID solid ON). System in degraded state (no manageability). Control has been passed from

BMC uBoot to BMC Linux* itself. It will be in this state for ~10-~20 seconds.

BMC Watchdog has reset the BMC.

Power Unit sensor offset for configuration error is asserted.

HDD HSC is off-line or degraded.

Non-fatal alarm

– system is likely to fail:

Critical threshold crossed

– Voltage, temperature (including HSBP temp), input power to power supply, output current for main power rail from power supply and PROCHOT (Therm Ctrl) sensors.

VRD Hot asserted.

Minimum number of fans to cool the system not present or failed

Hard drive fault

Power Unit Redundancy sensor

– Insufficient resources offset

(indicates not enough power supplies present)

In non-sparing and non-mirroring mode if the threshold of correctable errors is crossed within the window

Correctable memory error threshold has been reached for a failing

DDR3 DIMM when the system is operating in a non-redundant mode

Fatal alarm

– system has failed or shutdown:

CPU CATERR signal asserted

MSID mismatch detected (CATERR also asserts for this case).

CPU 1 is missing

CPU Thermal Trip

No power good

– power fault

DIMM failure when there is only 1 DIMM present and hence no good memory present.

Runtime memory uncorrectable error in non-redundant mode.

DIMM Thermal Trip or equivalent

SSB Thermal Trip or equivalent

CPU ERR2 signal asserted

BMC\Video memory test failed. (Chassis ID shows blue/solid-on for this condition)

Both uBoot BMC FW images are bad. (Chassis ID shows blue/solidon for this condition)

Revision 2.0 209

Color State Criticality Description

240VA fault

Fatal Error in processor initialization:

Processor family not identical

Processor model not identical

Processor core/thread counts not identical

Processor cache size not identical

Unable to synchronize processor frequency

Unable to synchronize QPI link frequency

11.3 BMC Boot/Reset Status LED Indicators

During the BMC boot or BMC reset process, the System Status LED and System ID LED are used to indicate BMC boot process transitions and states. A BMC boot will occur when AC power is first applied to the system. A BMC reset will occur after: a BMC FW update, upon receiving a BMC cold reset command, and upon a BMC watchdog initiated reset. The following table defines the LED states during the BMC Boot/Reset process.

Table 60. BMC Boot/Reset Status LED Indicators

BMC Boot/Reset State

BMC/Video memory test failed

Both Universal Bootloader (u-Boot) images bad

BMC in u-Boot

BMC Booting Linux*

End of BMC boot/reset process.

Normal system operation

ID LED Status

LED

Solid Blue Solid

Amber

Solid Blue Solid

Amber

Blink Blue

3Hz

Blink

Green

1Hz

Solid Blue Solid

Green

Off Solid

Green

Comment

Nonrecoverable condition. Contact your Intel

® representative for information on replacing this motherboard.

Nonrecoverable condition. Contact your Intel

® representative for information on replacing this motherboard.

Blinking green indicates degraded state (no manageability), blinking blue indicates u-Boot is running but has not transferred control to BMC

Linux*. Server will be in this state 6-8 seconds after BMC reset while it pulls the Linux* image into flash.

Solid green with solid blue after an AC cycle/BMC reset, indicates that the control has been passed from u-Boot to BMC Linux* itself. It will be in this state for ~10-~20 seconds.

Indicates BMC Linux* has booted and manageability functionality is up and running.

Fault/Status LEDs operate as per usual.

11.4 Post Code Diagnostic LEDs

A bank of eight POST code diagnostic LEDs are located on the back edge of the server next to the stacked USB connectors. During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number.

As each configuration routine is started, the BIOS displays the given POST code to the POST code diagnostic LEDs. The purpose of these LEDs is to assist in troubleshooting a system hang condition during the POST process. The diagnostic LEDs can be used to identify the last POST process to be executed. See Appendix D for a complete description of how these LEDs are read, and for a list of all supported POST codes.

210 Revision 2.0

11.5 5 Volt Stand-By Present LED

This LED is illuminated when a power cord (AC or DC) is connected to the server and the power supply is supplying 5 Volt Stand-by power to the server board. This LED is intended as a service caution indicator to anyone accessing the inside of the server system.

Revision 2.0 211

Environmental Limits Specification

12. Environmental Limits Specification

The following table defines the Intel

®

Server Board S1200V3RP series operating and nonoperating environmental limits. Operation of the Intel

®

Server Board S1200V3RP at conditions beyond those shown in the following table may cause permanent damage to the system.

Exposure to absolute maximum rating conditions for extended periods may affect system reliability.

Table 61. Server Board Design Specifications

Operating Temperature

Non-Operating Temperature

0º C to 55º C 1 (32º F to 131º F)

-40º C to 70º C (-40º F to 158º F)

DC Voltage

Shock (Unpackaged)

Shock (Packaged)

< 20 pounds

20 to < 40 pounds

40 to < 80 pounds

80 to < 100 pounds

100 to < 120 pounds

120 pounds

± 5% of all nominal voltages

Trapezoidal, 35g , 170 inches/sec

36 inches

30 inches

24 inches

18 inches

12 inches

9 inches

5 Hz to 500 Hz 3.13 g RMS random Vibration (Unpackaged)

Note:

Intel Corporation server boards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible, if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.

Disclaimer Note: Intel ensures the unpackaged server board and system meet the shock requirement mentioned above through its own chassis development and system configuration. It is the responsibility of the system integrator to determine the proper shock level of the board and system if the system integrator chooses different system configuration or different chassis.

Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits.

12.1 Processor Thermal Design Power (TDP) Support

To allow optimal operation and long-term reliability of Intel

®

processor-based systems, the processor must remain within the defined minimum and maximum case temperature (TCASE) specifications. Thermal solutions not designed to provide sufficient thermal capability may affect the long-term reliability of the processor and system. The server board is designed to support the Intel

®

Xeon

®

Processor E3-1200 V3/V4 product family TDP guidelines up to and including

95W.

Disclaimer Note: Intel Corporation server boards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel

®

ensures through its own chassis development and testing that when Intel

®

server building blocks are used together, the

212 Revision 2.0

Environmental Limits Specification

fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible, if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits.

12.2 MTBF

The following is the calculated Mean Time Between Failures (MTBF) 40 degree C (ambient air).

These values are derived using a historical failure rate and multiplied by factors for application, electrical and/or thermal stress and for device maturity. You should view MTBF estimates as

“reference numbers” only.

Calculate standard: Telcordia* issue 2

Calculate Method: Method I-D

Temperature = 40 degree C

Environment = GB, GC

– Ground Benign, Controlled

Model = Serial

Duty cycle = 100%

Component Quality: Level II

Adhere to De-rating data

Table 62. MTBF Estimate

Assembly Name

Intel

®

Server Board

S1200V3RPL

Intel

®

Server Board

S1200V3RPS

Intel

®

Server Board

S1200V3RPO

Intel

®

Server Board

S1200V3RPM

Temperature (Degree C)

40 283,887

MTBF (hours)

40

40

40

290,843

286,078

277,497

Revision 2.0 213

Server Board Power Distribution

13. Server Board Power Distribution

This section provides power supply design guidelines for a system using the Intel

®

Server Board

S1200V3RP. The following diagram shows the power distribution implemented on this server board.

The power supply data provided in this section is for reference purposes only. It reflects Intel’s own DC power out requirements for a 365W power supply as used in an Intel designed 4U server platform. The intent of this section is to provide customers with a guide to assist in defining and/or selecting a power supply for custom server platform designs that utilize the server boards detailed in this document.

Figure 49. Power Distribution Block Diagram

13.1 DC Output Specification

13.1.1 Output Power/Currents

The following table defines the minimum power and current ratings. The power supply meets both static and dynamic voltage regulation requirements for all conditions.

Table 63. Over Voltage Protection Limits

5V

Parameter

12V1

12V2

3.3V

12V

0.3

0.7

1.5

0.5

0.0

Min

10.0

Max.

16.0

16.0

18.0

0.5

18.0

Peak

18.0

A

Unit

A

A

A

A

214 Revision 2.0

Server Board Power Distribution

Parameter

5Vstby 0.0

Min

2.5

Max.

Note:

1. Max combined power for all output shall not exceed 350W.

2. Peak combined power for all outputs shall not exceed 400W.

3. Max combined power of 12V1 and 12V2 shall not exceed 318W.

3.0

Peak

A

Unit

4. Max combined power on 3.3V and 5V shall not exceed 100W.

5. Peak power and current loading shall be supported for a minimum of 12 second.

13.1.2 Cross Loading

The power supply maintains voltage regulation limit when operated over the following cross loading conditions.

Table 64. Loading Conditions

Load1

Load2

Load3

Load4

Load5

Load6

Load7

3.3V

10.8

18

18

13.6

0.5

16

1.2

5.0V

2

4.1

4.1

7

0.3

4

2.7

12.0V

16

7.6

16

10.2

0.7

0.7

14.5

12.0V

10.5

16

7.6

12

1.5

2.6

7.1

12.0V

0

0

0

0

0

0

0.5

5.0V

0.3

0.3

0.3

2.5

0.3

0.3

1

Total

Power

365

365

365

365

31

114

282

12V

Power

318

283

283

266

26

40

259

3.3V/5V

Power

46

80

80

80

3

73

17

13.1.3 Standby Output

The 5VSB output is present when an AC input greater than the power supply turn on voltage is applied.

13.1.4 Voltage Regulation

The power supply output voltages stay within the following voltage limits when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.

These shall be measured at the output connectors.

Table 65. Voltage Regulation Limits

PARAMETER

+3.3V

+5V

+12V1

+12V2

- 12V

+5VSB

TOLERANCE

- 5%/+5%

- 5%/+5%

- 5%/+5%

- 5%/+5%

- 10%/+10%

- 5%/+5%

MIN

+3.14

+4.75

+11.40

+11.40

- 13.20

+4.75

NOM

+3.30

+5.00

+12.00

+12.00

-12.00

+5.00

MAX

+3.46

+5.25

+12.60

+12.60

-10.80

+5.25

UNITS

V rms

V rms

V rms

V rms

V rms

V rms

Revision 2.0 215

Server Board Power Distribution

13.1.5 Dynamic Loading

The output voltages remain within limits specified for the step loading and capacitive loading specified in the table below. The load transient repetition rate is tested between 50Hz and 5kHz at duty cycles ranging from 10%-90%. The load transient repetition rate is only a test specification. The

step load may occur anywhere within the MIN load to the MAX load conditions.

Table 66. Transient Load Requirements

Output  Step Load Size

(See note 2)

6.0A

Load Slow Rate

+3.3V

+5V

12V1+12V2

+5VSB

4.0A

18.0A

0.5A

0.5 A/

 sec

0.5 A/

 sec

0.5 A/

 sec

0.5 A/

 sec

Note:

1. Step loads on each 12V output may happen simultaneously.

Test capacitive Load

970

F

400

F

2200

F

1,2

20

F

2. The +12V should be tested with 2200

F evenly split between the four +12V rails.

13.1.6 Capacitive Loading

The power supply is stable and meets all requirements with the following capacitive loading ranges.

Table 67. Capacitive Loading Conditions

Output

+3.3V

+5V

+12V

-12V

+5VSB

250

400

500

1

20

MIN

5000

MAX

5000

8000

350

350

F

Units

F

F

F

F

13.1.7 Grounding

The output ground of the pins of the power supply provides the output power return path. The output connector ground pins are connected to the safety ground (power supply enclosure).

This grounding is well designed to ensure passing the max allowed Common Mode Noise levels.

The power supply is provided with a reliable protective earth ground. All secondary circuits are connected to protective earth ground. Resistance of the ground returns to chassis does not exceed 1.0 m

Ω. This path may be used to carry DC current.

13.1.8 Residual Voltage Immunity in Standy mode

The power supply is immune to any residual voltage placed on its outputs (Typically a leakage voltage through the system from standby output) up to 500mV. There is neither additional heat generated, nor stressing of any internal components with this voltage applied to any individual or all outputs simultaneously. It also does not trip the protection circuits during turn on.

216 Revision 2.0

Server Board Power Distribution

The residual voltage at the power supply outputs for no load condition does not exceed 100mV when AC voltage is applied and the PSON# signal is de-asserted.

13.1.9 Common Mode Noise

The Common Mode noise on any output does not exceed 350mV pk-pk over the frequency band of 10Hz to 20MHz.

The measurement is made across a 100Ω resistor between each of DC outputs, including ground at the DC power connector and chassis ground (power subsystem enclosure).

The test set-up shall use a FET probe such as Tektronix* model P6046 or equivalent.

13.1.10 Ripple/Noise

The maximum allowed ripple/noise output of the power supply is defined in below table. This is measured over a bandwidth of 10Hz to 20MHz at the power supply output connectors. A 10

F tantalum capacitor in parallel with a 0.1

F ceramic capacitor is placed at the point of measurement.

Table 68. Ripples and Noise

+3.3V

50mVp-p

+5V +12V 1

50mVp-p 120mVp-p

The test set-up shall be as shown below.

AC HOT

POWER SUPPLY

AC NEUTRAL

V

OUT

V

RETURN

+12V 2

120mVp-p

10uF

.1uF

-12V +5VSB

200mVp-p 50mVp-p

LOAD

LOAD MUST BE

ISOLATED FROM

THE GROUND OF

THE POWER

SUPPLY

AC GROUND

GENERAL NOTES:

1. LOAD THE OUTPUT WITH ITS MINIMUM

LOAD CURRENT.

2. CONNECT THE PROBES AS SHOWN.

3. REPEAT THE MEASUREMENTS WITH THE

MAXIMUM LOAD ON THE OUTPUT.

SCOPE

SCOPE NOTE:

USE A TEKTRONIX 7834 OSCILLOSCOPE WITH 7A13 AND

DIFFERENTIAL PROBE P6055 OR EQUIVALENT.

Figure 50. Differential Noise test setup

Note: When performing this test, the probe clips and capacitors should be located close to the load.

13.1.11 Timing Requirements

These are the timing requirements for the power supply operation. The output voltages rise from

10% to within regulation limits (T vout_rise

) within 2 to 50ms, except for 5VSB - it is allowed to rise from 1 to 25ms. The +3.3V, +5V and +12V1, +12V2 output voltages should start to rise approximately at the same time. All outputs must rise monotonically. Each output voltage reach regulation within 50ms (T vout_on

) of each other during turn on the power supply. Each output voltage fall out of regulation within 400ms (T vout_off

) of each other during turn off. The table below

Revision 2.0 217

Server Board Power Distribution shows the timing requirements for the power supply being turned on and off from the AC input, with PSON held low and the PSON signal, with the AC input applied.

Item

T vout_rise

T vout_on

T vout_off

Table 69. Output Voltage Timing

Description

Output voltage rise time from each main output. 2

Output rise time for the 5Vstby output.

All main outputs must be within regulation of each other within this time.

1

All main outputs must leave regulation within this time.

MIN

50

25

50

MAX

400 ms

UNITS ms ms ms

Item

T sb_on_delay

T ac_on_delay

T vout_holdup

T pwok_holdup

T pson_on_delay

Figure 51. Output Voltage Timing

Table 70. Turn On/Off Timing

Description

Delay from AC being applied to 5VSB being within regulation.

Delay from AC being applied to all output voltages being within regulation.

Time all output voltages stay within regulation after loss of AC. Tested at 75% of maximum load.

Delay from loss of AC to de-assertion of PWOK.

Tested at 75% of maximum load.

Delay from PSON# active to output voltages within regulation limits.

13

12

5

Min.

218

1500

Max.

2500

400 ms

Units ms ms ms ms

Revision 2.0

Server Board Power Distribution

Item

T pson_pwok

T pwok_on

T pwok_off

T pwok_low

T sb_vout

T

5VSB_holdup

AC Input

Description

Delay from PSON# deactivate to PWOK being de-asserted.

Delay from output voltages within regulation limits to PWOK asserted at turn on.

Delay from PWOK de-asserted to output voltages (3.3V, 5V, 12V, -12V) dropping out of regulation limits.

Duration of PWOK being in the de-asserted state during an off/on cycle using AC or the PSON signal.

Delay from 5VSB being in regulation to O/Ps being in regulation at AC turn on.

Time the 5VSB output voltage stays within regulation after loss of AC.

100

1

100

10

70

Min.

T vout_holdup

Vout

T sb_on_delay

PWOK

T

AC_on_delay

T pwok_on

T pwok_holdup

T pwok_off

T pwok_low

T sb_on_delay

T pwok_on

50

Max.

500

1000 ms

Units ms ms ms ms ms

T pwok_off

T pson_pwok

5VSB

T sb_vout

T

5VSB

_ holdup

T pson_on_delay

PSON

AC turn on/off cycle

PSON turn on/off cycle

Figure 52. Turn On/Off Timing (Power Supply Signals)

Revision 2.0 219

Appendix A: Integration and Usage Tips

Appendix A: Integration and Usage Tips

When adding or removing components or peripherals from the server board, you must remove AC power cord. With AC power plugged into the server board, 5-V standby is still present even though the server board is powered off.

This server board supports Intel

®

Xeon

®

Processor E3-1200 V3/V4 product family with a

Thermal Design Power (TDP) of up to and including 95 Watts. Previous generation Intel

®

Xeon

®

processors are not supported.

The PCIe slot 4 does NOT support the Intel

®

PCIe gen3 ROC modules.

The onboard SATA connectors 0 and 1 are designed to support the ODD or SSD, do

NOT connect SATA connector 0 and 1 to the backplane. The onboard SATA connectors

2-5 are designed to support the backplane.

On the back edge of the server board are EIGHT diagnostic LEDs that display a sequence of amber POST codes during the boot process. If the server board hangs during POST, the LEDs display the last POST event run before the hang.

Only Unbuffered DDR3L DIMMs (UDIMMs) are supported on this server board. Mixing of

RDIMMs and UDIMMs is not supported.

The Intel

®

RMM4/RMM4 Lite connectors are not compatible with the previous Intel

®

Remote Management Modules

Clear CMOS with the AC power cord plugged in. Removing AC power before performing the CMOS Clear operation causes the system to automatically power up and immediately power down after the CMOS Clear procedure is followed and AC power is re-applied. If this happens, remove the AC power cord, wait 30 seconds, and then reconnect the AC power cord. Power up the system and proceed to the <F2> BIOS Setup

Utility to reset the desired settings.

Normal BMC functionality is disabled with the Force BMC Update jumper (J3K6) set to the “enabled” position (pins 2-3). You should never run the server with the Force BMC

Update jumper set in this position and should only use the jumper in this position when the standard firmware update process fails. This jumper must remain in the default

(disabled) position (pins 1-2) when the server is running normally.

This server board no longer supports the Rolling BIOS (two BIOS banks). It implements the BIOS Recovery mechanism instead.

When performing a normal BIOS update procedure, you must set the BIOS Recovery jumper (J2K8) to its default position (pins 1-2).

220 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Appendix B: Integrated BMC Sensor Tables

This appendix lists the sensor identification numbers and information about the sensor type, name, supported thresholds, assertion and de-assertion information, and a brief description of the sensor purpose. See the Intelligent Platform Management Interface Specification, Version

2.0 for sensor and event/reading-type table information.

Sensor Type

The Sensor Type is the value enumerated in the Sensor Type Codes table in the IPMI specification. The Sensor Type provides the context in which to interpret the sensor, such as the physical entity or characteristic represented by this sensor.

Event/Reading Type

The Event/Reading Type values are from the Event/Reading Type Code Ranges and

Generic Event/Reading Type Codes tables in the IPMI specification. Digital sensors are a specific type of discrete sensor with only two states.

Event Offset/Triggers

Event Thresholds are event-generating thresholds for threshold type sensors.

-

[u,l][nr,c,nc]: upper nonrecoverable, upper critical, upper noncritical, lower nonrecoverable, lower critical, lower noncritical

- uc, lc: upper critical, lower critical

Event Triggers are supported, event-generating offsets for discrete type sensors. You can find the offsets in the Generic Event/Reading Type Codes or Sensor Type Codes tables in the IPMI specification, depending on whether the sensor event/reading type is generic or a sensor-specific response.

Assertion/De-assertion Enables

Assertion and de-assertion indicators reveal the type of events the sensor generates:

- As: Assertions

-

De: De-assertion

Readable Value/Offsets

- Readable Values indicate the type of value returned for threshold and other nondiscrete type sensors.

-

Readable Offsets indicate the offsets for discrete sensors that are readable with the

Get Sensor Reading command. Unless indicated, all event triggers are readable;

Readable Offsets consist of the reading type offsets that do not generate events.

Event Data

Event data is the data included in an event message generated by the sensor. For threshold-based sensors, the following abbreviations are used:

- R: Reading value

-

T: Threshold value

Rearm Sensors

The rearm is a request for the event status of a sensor to be rechecked and updated upon a transition between good and bad states. You can rearm the sensors manually or automatically. This column indicates the type supported by the sensor. The following abbreviations are used in the comment column to describe a sensor:

Revision 2.0 221

Appendix B: Integrated BMC Sensor Tables

-

A: Auto-rearm

- M: Manual rearm

Default Hysteresis

The hysteresis setting applies to all thresholds of the sensor. This column provides the count of hysteresis for the sensor, which is 1 or 2 (positive or negative hysteresis).

Criticality

Criticality is a classification of the severity and nature of the condition. It also controls the behavior of the Control Panel Status LED.

Standby

Some sensors operate on standby power. You can access these sensors and/or generate events when the main (system) power is off but AC power is present.

Table 71. Integrated BMC Core Sensors

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Power Unit

Status

(Pwr Unit

Status)

Power Unit

Redundancy

1 (Pwr Unit

Redund)

IPMI

Watchdog

01 h

02 h

03 h

All

Chassisspecific

All

Sensor

Type

Event/R eading

Type

Event Offset Triggers Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s

Power

Unit

09h

Power

Unit

09h

Watchd og 2

Sensor

Specifi c

6Fh

Generi c

0Bh

Sensor

Specifi

00 - Power down

02 - 240 VA power down

04 - A/C lost

OK

Fatal

OK

05 - Soft power control failure

Fatal

06 - Power unit failure

00 - Fully Redundant OK

01 - Redundancy lost Degrad ed

02 - Redundancy degraded

Degrad ed

Degrad ed

03 - Non-redundant: sufficient resources.

Transition from full redundant state.

04

– Non-redundant: sufficient resources.

Transition from insufficient state.

05 - Non-redundant: insufficient resources

06

– Redundant: degraded from fully redundant state.

07

– Redundant:

Transition from nonredundant state.

00 - Timer expired, status only

Degrad ed

Fatal

Degrad ed

Degrad ed

OK

As and

De

As and

De

As

Event

Data

Rearm St an db y

Trig

Offset

A

Trig

Offset

M

Trig

Offset

A

X

X

X

222 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

(IPMI

Watchdog)

Physical

Security

(Physical

Scrty)

FP Interrupt

(FP NMI

Diag Int)

SMI Timeout

(SMI

Timeout)

System

Event Log

(System

Event Log)

System

Event

(System

Event)

Button

Sensor

(Button)

BMC

Watchdog

Voltage

Regulator

Watchdog

(VR

Watchdog)

Fan

Redundancy

1

(Fan

Redundancy

)

04 h

05 h

06 h

07 h

08 h

09 h

0

A h

0

B h

0

C h

Chassis

Intrusion is chassisspecific

Chassis specific

All

All

All

All

All

All

Chassisspecific

Sensor

Type

Event/R eading

Type

Event Offset Triggers Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s

23h c

6Fh

01 - Hard reset

02 - Power down

03 - Power cycle

08 - Timer interrupt

00 - Chassis intrusion

04 - LAN leash lost

SMI

Timeou t

F3h

Event

Loggin g

Disable d

10h

Physica l

Securit y

05h

Critical

Interrup t

13h

Sensor

Specifi c

6Fh

Sensor

Specifi c

6Fh

Digital

Discret e

03h

Sensor

Specifi c

6Fh

System

Event

12h

Button/

Switch

14h

Mgmt

System

Health

28h

Sensor

Specifi c

6Fh

Sensor

Specifi c

6Fh

Digital

Discret e

03h

00 - Front panel

NMI/diagnostic interrupt

01

– State asserted

02 - Log area reset/cleared

02 - Undetermined system H/W failure

04

– PEF action

00

– Power Button

02

– Reset Button

01

– State Asserted

Degrad ed

OK

OK

Fatal

OK

Fatal

OK

OK

Degrad ed

Voltage

02h

Digital

Discret e

03h

01

– State Asserted

Fatal

Fan

04h

Generi c

0Bh

00 - Fully redundant OK

01 - Redundancy lost Degrad ed

02 - Redundancy degraded

03 - Non-redundant:

Degrad ed

Degrad

As and

De

As

As and

De

As

As and

De

As

AS

As

As and

De

As and

De

-

_

Event

Data

Rearm St an db y

Trig

Offset

A

Trig

Offset

A

Trig

Offset

A

Trig

Offset

A

Trig

Offset

A

Trig

Offset

A

Trig

Offset

A

Trig

Offset

M

Trig

Offset

A

X

X

X

X

-

X

Revision 2.0 223

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

SSB

Thermal Trip

(SSB Therm

Trip)

IO Module

Presence

(IO Mod

Presence)

SAS Module

Presence

(SAS Mod

Presence)

BMC

Firmware

Health

(BMC FW

Health)

System

Airflow

(System

Airflow)

FW Update

Status

0

D h

0

E h

0

F h

10 h

11 h

12 h

IO Module2

Presence

(IO Mod2

Presence)

13 h

Baseboard

Temperature

5

(Platform

Specific)

14 h

All

Platformspecific

Platformspecific

All

All

All

Platformspecific

Platformspecific

Sensor

Type

Event/R eading

Type

Event Offset Triggers Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s

Sufficient resources.

Transition from redundant

04 - Non-redundant:

Sufficient resources.

Transition from insufficient.

05 - Non-redundant: insufficient resources.

06

– Non-Redundant: degraded from fully redundant. ed

Degrad ed

Non-

Fatal

Degrad ed

Temper ature

01h

Module

/Board

15h

Module

/Board

15h

Digital

Discret e

03h

Digital

Discret e

08h

Digital

Discret e

08h

Mgmt

Health

28h

01

01

01

– State Asserted

– Inserted/Present

– Inserted/Present

Sensor

Specifi c

6Fh

04

– Sensor Failure

Fatal

OK

OK

Degrad ed

As and

De

As and

De

As and

De

As

-

Event

Data

Rearm St an db y

Trig

Offset

M

Trig

Offset

M

Trig

Offset

M

Trig

Offset

A

X

-

X

X

Other

Units

0Bh

Thresh old

01h

– –

Version

Change

2Bh

OEM defined x70h

00hUpdate started

01hUpdate completed successfully.

02hUpdate failure

Module

/Board

15h

Digital

Discret e

08h

01

– Inserted/Present

OK

OK

Temper ature

01h

Thresh old

01h

[u,l] [c,nc] nc =

Degrad ed c =

Nonfatal

As

As and

De

As and

De

Analo g

_

Analo g

Trig

Offset

Trig

Offset

R, T

A

M

A

_

-

X

224 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

IO Module2

Temperature

(I/O Mod2

Temp)

16 h

Platformspecific

Temper ature

01h

Thresh old

01h

Front Panel

Temperature

(Front Panel

Temp)

Se ns or

#

Baseboard

Temperature

6

(Platform

Specific)

15 h

PCI Riser 3

Temperature

(PCI Riser 5

Temp)

17 h

PCI Riser 4

Temperature

(PCI Riser 4

Temp)

18 h

Baseboard

+1.05V

Processor3

Vccp

(BB

+1.05Vccp

P3)

Baseboard

+1.05V

Processor4

Vccp

(BB

+1.05Vccp

P4)

19 h

1

A h

Baseboard

Temperature

1

(Platform

Specific)

20 h

21 h

Platform

Applicabilit

All y

Platformspecific

Platformspecific

Platformspecific

Platformspecific

Platformspecific

Platformspecific

Sensor

Type

Temper ature

01h

Temper ature

01h

Temper ature

01h

Voltage

02h

Voltage

02h

Thresh old

01h

Temper ature

01h

Thresh old

01h

Temper ature

01h

Event/R eading

Type

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Event Offset Triggers

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal

As and

De

As and

De

As and

De

As and

De

As and

De

Analo g

Analo g

Analo g

Analo g

Analo g

Event

Data

R, T A

R, T A

R, T

R, T

R, T

Rearm St an db y

A

A

A

X

X

X

X

– nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal

As and

De

As and

De

As and

De

Analo g

Analo g

Analo g

R, T

R, T

R, T

A

A

A

X

X

Revision 2.0 225

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

SSB

Temperature

(SSB Temp)

Hot-swap

Backplane 1

Temperature

(HSBP 1

Temp)

Hot-swap

Backplane 2

Se ns or

2

#

22 h

Baseboard

Temperature

2

(Platform

Specific)

23 h

Baseboard

Temperature

3

(Platform

Specific)

24 h

Baseboard

Temperature

4

(Platform

Specific)

25 h

PCI Riser 1

Temperature

(PCI Riser 1

Temp)

27 h

IO Riser

Temperature

(IO Riser

Temp)

28 h

29 h

A

Platform

Applicabilit

All y

Platformspecific

Platformspecific

Platformspecific

IO Module

Temperature

(I/O Mod

Temp)

26 h

Platformspecific

Platformspecific

Platformspecific

Chassisspecific

Chassisspecific

Sensor

Type

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Event/R eading

Type

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Temper ature

Thresh old

Event Offset Triggers

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Event

Data

R, T

R, T A

R, T

R, T

R, T

R, T

R, T

R, T

R, T

Rearm St an db y

A

A

A

A

A

A

A

A

X

X

X

X

X

X

X

X

X

226 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Temperature

(HSBP 2

Temp) h

Hot-swap

Backplane 3

Temperature

(HSBP 3

Temp)

PCI Riser 2

Temperature

(PCI Riser 2

Temp)

SAS Module

Temperature

(SAS Mod

Temp)

Exit Air

Temperature

(Exit Air

Temp)

2

B h

2

C h

2

D h

2

E h

Chassisspecific

Platformspecific

Platformspecific

Chassis and

Platform

Specific

Network

Interface

Controller

Temperature

(LAN NIC

Temp)

Fan

Tachometer

Sensors

(Chassis specific sensor names)

2

F h

30 h

3

F h

Fan Present

Sensors

(Fan x

Present)

40 h

4

F h

Power

Supply 1

Status

(PS1 Status)

50 h

All

Chassis and

Platform

Specific

Chassis and

Platform

Specific

Chassisspecific

Sensor

Type

01h

Temper ature

01h

Thresh old

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Fan

04h

Fan

04h

Power

Supply

08h

Event/R eading

Type

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Generi c

08h

Event Offset Triggers

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[l] [c,nc]

01 - Device inserted

Sensor

Specifi c

6Fh

00 - Presence

01 - Failure

02

– Predictive

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s

De nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal2

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Event

Data

Rearm St an db y

R, T A

R, T A

R, T A

R, T A

R, T A

R, T M

X

X

X

X

X

-

OK

OK

Degrad ed

Degrad

As and

De

As and

De

-

Trigg ered

Offset

Trig

Offset

Auto

A

-

X

Revision 2.0 227

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Sensor

Type

Event/R eading

Type

Event Offset Triggers

Failure

03 - A/C lost

Power

Supply 2

Status

(PS2 Status)

51 h

Chassisspecific

Power

Supply

08h

Sensor

Specifi c

6Fh

06

– Configuration error

00 - Presence

01 - Failure

02

– Predictive

Failure

03 - A/C lost

06

– Configuration error

Power

Supply 1

AC Power

Input

(PS1 Power

In)

Power

Supply 2

AC Power

Input

(PS2 Power

In)

Power

Supply 1

+12V % of

Maximum

Current

Output

(PS1 Curr

Out %)

Power

Supply 2

+12V % of

Maximum

Current

Output

(PS2 Curr

Out %)

Power

Supply 1

Temperature

(PS1

Temperature

)

Power

54 h

55 h

58 h

59 h

5

C h

Chassisspecific

Chassisspecific

Chassisspecific

Chassisspecific

Chassisspecific

Other

Units

0Bh

Other

Units

0Bh

Current

03h

Current

03h

Temper ature

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

[u] [c,nc]

[u] [c,nc]

[u] [c,nc]

[u] [c,nc]

[u] [c,nc]

5 ChassisTemper Thresh

[u] [c,nc]

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s ed

Degrad ed

OK

OK

Degrad ed

Degrad ed

Degrad ed

OK nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal

As and

De

As and

De

As and

De

Analo g

Analo g

Event

Data

Trig

Offset

R, T A

R, T

Rearm St an db y

A

A

X

X

X nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal nc =

As and

De

As

Analo g

Analo g

Analo g

Analo

R, T

R, T

R, T

R, T

A

A

A

A

X

X

X

X

228 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Sensor

Type

Event/R eading

Type

Event Offset Triggers

Supply 2

Temperature

(PS2

Temperature

)

Hard Disk

Drive 16 - 24

Status

(HDD 16 -

24 Status)

D h

60 h

68 h specific

Chassisspecific ature

Drive

Slot

0Dh old

01h

Sensor

Specifi c

6Fh

00 - Drive Presence

01- Drive Fault

07 - Rebuild/Remap in progress

04- transition to Off

Line

01 - Thermal trip

Processor 1

Status

(P1 Status)

Processor 2

Status

(P2 Status)

Processor 3

Status

(P3 Status)

Processor 4

Status

(P4 Status)

70 h

71 h

72 h

73 h

All

All

Platformspecific

Platformspecific

Proces sor

07h

Proces sor

07h

Proces sor

07h

Proces sor

07h

07 - Presence

01 - Thermal trip

07 - Presence

01 - Thermal trip

07 - Presence

01 - Thermal trip

07 - Presence

Processor 1

Thermal

Margin

(P1 Therm

Margin)

Processor 2

Thermal

Margin

(P2 Therm

Margin)

Processor 3

Thermal

Margin

(P3 Therm

Margin)

74 h

75 h

76 h

All

All

Platformspecific

Temper ature

01h

Temper ature

01h

Temper ature

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

-

-

-

Processor 4 77 PlatformTemper Thresh

-

Sensor

Specifi c

6Fh

Sensor

Specifi c

6Fh

Sensor

Specifi c

6Fh

Sensor

Specifi c

6Fh

Contrib.

To

System

Status

Assert

/Deassert and

De

Reada ble

Value/

Offset s g Degrad ed c =

Nonfatal

OK

Degrad ed

As and

De

Event

Data

Trig

Offset

Rearm St an db y

A

X

Degrad ed

Degrad ed

Fatal

OK

As and

De

Fatal

OK

As and

De

Fatal

OK

As and

De

Fatal

OK

As and

De

-

-

-

-

-

-

-

-

Analo g

Analo g

Analo g

Analo

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

R, T

R, T

R, T

R, T

M

M

M

M

A

A

A

A

X

X

X

X

X

Revision 2.0 229

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Thermal

Margin

(P4 Therm

Margin)

Processor 1

Thermal

Control %

(P1 Therm

Ctrl %) h specific

78 h

All

Sensor

Type ature

01h

Event/R eading

Type old

01h

Event Offset Triggers

Temper ature

01h

Thresh old

01h

[u] [c,nc]

Processor 2

Thermal

Control %

(P2 Therm

Ctrl %)

Processor 3

Thermal

Control %

(P3 Therm

Ctrl %)

Processor 4

Thermal

Control %

(P4 Therm

Ctrl %)

Processor 1

ERR2

Timeout

(P1 ERR2)

Processor 2

ERR2

Timeout

(P2 ERR2)

Processor 3

ERR2

Timeout

(P3 ERR2)

Processor 4

ERR2

Timeout

(P4 ERR2)

79 h

7

A h

7

B h

7

C h

7

D h

7

E h

7

F h

All

Platformspecific

Platformspecific

All

All

Platformspecific

Platformspecific

Catastrophic

Error

(CATERR)

80 h

All

Processor1 81

All

Temper ature

01h

Temper ature

01h

Temper ature

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Proces sor

07h

Proces sor

07h

Proces sor

07h

Proces sor

07h

Proces sor

07h

Digital

Discret e

03h

Digital

Discret e

03h

Digital

Discret e

03h

Digital

Discret e

03h

Digital

Discret e

03h

Proces Digital

[u] [c,nc]

[u] [c,nc]

[u] [c,nc]

01

– State Asserted

01

– State Asserted

01

– State Asserted

01

– State Asserted

01

– State Asserted

01

– State Asserted

Contrib.

To

System

Status nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal

As and

De

As and

De

As and

De

As and

De fatal

As and

De fatal fatal fatal fatal fatal

Assert

/Deassert

Reada ble

Value/

Offset s g

As and

De

As and

De

As and

De

As and

De

As

Analo g

Analo g

Analo g

Analo g

Event

Data

Rearm St an db y

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

A

A

A

A

A

A

A

A

M

M

230 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Processor 3

DTS

Thermal

Margin

(P3 DTS

Therm Mgn)

Processor 4

DTS

Thermal

Margin

(P4 DTS

Therm Mgn)

Processor2

MSID

Mismatch

(P2 MSID

Mismatch)

Processor 1

VRD

Temperature

(P1 VRD

Hot)

MSID

Mismatch

(P1 MSID

Mismatch)

Processor

Population

Fault

(CPU

Missing)

Processor 1

DTS

Thermal

Margin

(P1 DTS

Therm Mgn)

Processor 2

DTS

Thermal

Margin

(P2 DTS

Therm Mgn)

Processor 2

VRD

Temperature

(P2 VRD

Hot) h

82 h

83 h

84 h

85 h

86 h

87 h

90 h

91 h

Processor 3 92

All

All

All

All

All

All

All

All

All

Sensor

Type sor

07h

Event/R eading

Type

Discret e

03h

Proces sor

07h

Digital

Discret e

03h

01

– State Asserted

Temper ature

01h

Thresh old

01h

-

Temper ature

01h

Thresh old

01h

-

Temper ature

01h

Thresh old

01h

-

Temper ature

01h

Thresh old

01h

-

Proces sor

07h

Digital

Discret e

03h

01

– State Asserted

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

Temper Digital

Event Offset Triggers

01 - Limit exceeded

01 - Limit exceeded

Fatal

-

-

-

- fatal

Nonfatal

Nonfatal

Fatal

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s and

De

Event

Data

Offset

Rearm St an db y

As and

De

-

-

-

-

As and

De

As and

De

As and

De

As

Analo g

Analo g

Analo g

Analo g

Trig

Offset

R, T

R, T

R, T

R, T

Trig

Offset

Trig

Offset

Trig

Offset

Trig

M

A

A

A

A

M

M

M

M

Revision 2.0 231

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Processor 2

Memory

VRD Hot 0-1

(P2 Mem01

VRD Hot)

Processor 2

Memory

VRD Hot 2-3

(P2 Mem23

VRD Hot)

Processor 3

Memory

VRD Hot 0-1

(P3 Mem01

VRD Hot)

Processor 3

Memory

VRD Hot 2-3

(P4 Mem23

VRD Hot)

VRD

Temperature

(P3 VRD

Hot)

Processor 4

VRD

Temperature

(P4 VRD

Hot)

Processor 1

Memory

VRD Hot 0-1

(P1 Mem01

VRD Hot)

Processor 1

Memory

VRD Hot 2-3

(P1 Mem23

VRD Hot)

Processor 4

Memory

VRD Hot 0-1

(P4 Mem01

VRD Hot)

Processor 4

Memory

VRD Hot 2-3

(P4 Mem23

VRD Hot) h

93 h

94 h

95 h

96 h

97 h

98 h

99 h

9

A h

9

B h

All

All

All

All

All

All

All

All

All

Sensor

Type ature

01h

Event/R eading

Type

Discret e

05h

Event Offset Triggers

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Temper ature

01h

Digital

Discret e

05h

01 - Limit exceeded

Fatal

Nonfatal

Nonfatal

Nonfatal

Nonfatal

Nonfatal

Nonfatal

Nonfatal

Nonfatal

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s and

De

Event

Data

Offset

Rearm St an db y

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

M

A

A

A

A

A

A

A

A

232 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Power

Supply 1

Fan

Tachometer

1

(PS1 Fan

Tach 1)

Power

Supply 1

Fan

Tachometer

2

(PS1 Fan

Tach 2)

Power

Supply 2

Fan

Tachometer

1

(PS2 Fan

Tach 1)

Power

Supply 2

Fan

Tachometer

2

(PS2 Fan

Tach 2)

Processor 1

DIMM

Aggregate

Thermal

Margin 1

(P1 DIMM

Thrm

Mrgn1)

Processor 1

DIMM

Aggregate

Thermal

Margin 2

(P1 DIMM

Thrm

Mrgn2)

Processor 2

DIMM

Aggregate

Thermal

Margin 1

(P2 DIMM

Thrm

Mrgn1)

A

0h

Chassisspecific

A

1h

A

4h

A

5h

B

0h

B

1h

B

2h

Chassisspecific

Chassisspecific

Chassisspecific

All

All

All

Sensor

Type

Fan

04h

Fan

04h

Fan

04h

Fan

04h

Event/R eading

Type

Generi c

– digital discret e

Generi c

– digital discret e

Generi c discret e

Generi c

– digital discret e

– digital

Event Offset Triggers

01

01

01

01

– State Asserted

– State Asserted

– State Asserted

– State Asserted

Temper ature

01h

Thresh old

01h

[u,l] [c,nc]

Temper ature

01h

Thresh old

01h

[u,l] [c,nc]

Temper ature

01h

Thresh old

01h

[u,l] [c,nc]

Contrib.

To

System

Status

Nonfatal

Nonfatal

Nonfatal

Nonfatal nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal

As and

De

Assert

/Deassert

Reada ble

Value/

Offset s

As and

De

As and

De

As and

De

As and

De

-

-

-

-

Analo g

Analo g

Analo g

Event

Data

Rearm St an db y

Trig

Offset

Trig

Offset

Trig

Offset

Trig

Offset

R, T

R, T

R, T

M

M

M

M

A

A

A

-

-

-

-

Revision 2.0 233

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Sensor

Type

Event/R eading

Type

Event Offset Triggers

Processor 2

DIMM

Aggregate

Thermal

Margin 2

(P2 DIMM

Thrm

Mrgn2)

Processor 3

DIMM

Aggregate

Thermal

Margin 1

(P3 DIMM

Thrm

Mrgn1)

Processor 3

DIMM

Aggregate

Thermal

Margin 2

(P3 DIMM

Thrm

Mrgn2)

Processor 4

DIMM

Aggregate

Thermal

Margin 1

(P4 DIMM

Thrm

Mrgn1)

Processor 4

DIMM

Aggregate

Thermal

Margin 2

(P4 DIMM

Thrm

Mrgn2)

Fan

Tachometer

Sensors

(Chassis specific sensor names)

Processor 1

DIMM

Thermal Trip

(P1 Mem

B

3h

B

4h

B

5h

B

6h

B

7h

B

A h

B

F h

C

0h

All

Platform

Specific

Platform

Specific

Platform

Specific

Platform

Specific

Chassis and

Platform

Specific

All

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Fan

04h

Memor y

0Ch

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Digital

Discret e

03h

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[l] [c,nc]

0A- Critical overtemperature

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s nc =

Degrad ed c =

Nonfatal

As and

De

Analo g

Event

Data

Rearm St an db y

R, T A

– nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal

As and

De nc =

Degrad ed c =

Nonfatal2

As and

De

Fatal

As and

De

Analo g

Analo g

Analo g

Analo g

Analo g

R, T

R, T

R, T

R, T

R, T

Trig

Offset

A

A

A

A

M

M

-

-

234 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Sensor

Type

Event/R eading

Type

Event Offset Triggers

Thrm Trip)

Processor 2

DIMM

Thermal Trip

(P2 Mem

Thrm Trip)

Processor 3

DIMM

Thermal Trip

(P3 Mem

Thrm Trip)

Processor 4

DIMM

Thermal Trip

(P4 Mem

Thrm Trip)

Global

Aggregate

Temperature

Margin 1

(Agg Therm

Mrgn 1)

Global

Aggregate

Temperature

Margin 2

(Agg Therm

Mrgn 2)

Global

Aggregate

Temperature

Margin 3

(Agg Therm

Mrgn 3)

Global

Aggregate

Temperature

Margin 4

(Agg Therm

Mrgn 4)

Global

Aggregate

Temperature

Margin 5

(Agg Therm

Mrgn 5)

Global

Aggregate

Temperature

C

1h

C

2h

C

3h

C

8h

C

9h

C

A h

C

B h

C

C h

C

D h

All

All

All

Platform

Specific

Platform

Specific

Platform

Specific

Platform

Specific

Platform

Specific

Platform

Specific

Memor y

0Ch

Memor y

0Ch

Memor y

0Ch

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Temper ature

01h

Digital

Discret e

03h

Digital

Discret e

03h

Digital

Discret e

03h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Temper ature

Thresh old

0A- Critical over temperature

0A- Critical overtemperature

0A- Critical overtemperature

-

-

-

-

-

-

Fatal

Fatal

Fatal

-

-

-

-

-

-

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s

Event

Data

Rearm St an db y

As and

De

As and

De

As and

De

-

-

-

-

-

-

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Trig

Offset

Trig

Offset

Trig

Offset

R, T

R, T

R, T

R, T

R, T

R, T

M

M

M

A

A

A

A

A

A

-

X

X

Revision 2.0 235

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Margin 6

(Agg Therm

Mrgn 6)

Global

Aggregate

Temperature

Margin 7

(Agg Therm

Mrgn 7)

Global

Aggregate

Temperature

Margin 8

(Agg Therm

Mrgn 8)

C

E h

C

F h

Platform

Specific

Platform

Specific

Sensor

Type

01h

Temper ature

01h

Temper ature

01h

Event/R eading

Type

01h

Thresh old

01h

Thresh old

01h

-

-

Event Offset Triggers

-

-

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s

Event

Data

Rearm St an db y

-

-

Analo g

Analo g

R, T

R, T

A

A

Baseboard

+12V

(BB +12.0V)

Baseboard

+5V

(BB +5.0V)

Baseboard

+3.3V

(BB +3.3V)

Baseboard

+5V Standby

(BB +5.0V

STBY)

Baseboard

+3.3V

Auxiliary

(BB +3.3V

AUX)

Baseboard

+1.05V

Processor1

Vccp

(BB

D

0h

D

1h

D

2h

D

3h

D

4h

D

6h

All

All

All

All

All

All

Voltage

02h

Voltage

02h

Voltage

02h

Voltage

02h

Voltage

02h

Voltage

02h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc] nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonnc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

R, T

R, T

R, T

R, T

R, T

R, T

A

A

A

A

A

A

X

X

236 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

+1.05Vccp

P1)

Baseboard

+1.05V

Processor2

Vccp

(BB

+1.05Vccp

P2)

Baseboard

+1.5V P1

Memory AB

VDDQ

(BB +1.5

P1MEM AB)

Baseboard

+1.5V P1

Memory CD

VDDQ

(BB +1.5

P1MEM CD)

Baseboard

+1.5V P2

Memory AB

VDDQ

(BB +1.5

P2MEM AB)

Baseboard

+1.5V P2

Memory CD

VDDQ

(BB +1.5

P2MEM CD)

D

7h

D

8h

D

9h

D

A h

D

B h

All

All

All

All

All

Sensor

Type

Event/R eading

Type

Event Offset Triggers

Voltage

02h

Thresh old

01h

[u,l] [c,nc]

Voltage

02h

Thresh old

01h

[u,l] [c,nc]

Voltage

02h

Thresh old

01h

[u,l] [c,nc]

Voltage

02h

Thresh old

01h

[u,l] [c,nc]

Voltage

02h

Thresh old

01h

[u,l] [c,nc]

Baseboard

+1.8V Aux

(BB +1.8V

AUX)

Baseboard

+1.1V

Stand-by

(BB +1.1V

STBY)

Baseboard

CMOS

Battery

(BB +3.3V

Vbat)

D

C h

D

D h

D

E h

All

All

All

Voltage

02h

Voltage

02h

Voltage

02h

Thresh old

01h

Thresh old

01h

Thresh old

01h

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s fatal

Event

Data

Rearm St an db y nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Non-

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

As and

De

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

Analo g

R, T

R, T

R, T

R, T

R, T

R, T

R, T

R, T

A

A

A

A

A

A

A

A

Revision 2.0 237

Appendix B: Integrated BMC Sensor Tables

Full Sensor

Name

(Sensor name in SDR)

Se ns or

#

Platform

Applicabilit y

Sensor

Type

Event/R eading

Type

Baseboard

+1.35V P2

Low Voltage

Memory CD

VDDQ

(BB +1.35

P2LV CD)

Baseboard

+3.3V Riser

1 Power

Good

(BB +3.3

RSR1 PGD)

Baseboard

+3.3V Riser

2 Power

Good

(BB +3.3

RSR2 PGD)

Baseboard

+1.35V P1

Low Voltage

Memory AB

VDDQ

(BB +1.35

P1LV AB)

Baseboard

+1.35V P1

Low Voltage

Memory CD

VDDQ

(BB +1.35

P1LV CD)

Baseboard

+1.35V P2

Low Voltage

Memory AB

VDDQ

(BB +1.35

P2LV AB)

E

4h

E

5h

E

6h

E

7h

E

A h

E

B h

All

All

All

All

Platform

Specific

Platform

Specific

Voltage

02h

Thresh old

01h

[u,l] [c,nc]

Voltage

02h

Voltage

02h

Voltage

02h

Voltage

02h

Voltage

02h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

Thresh old

01h

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

[u,l] [c,nc]

Hard Disk

Drive 1 -15

Status

(HDD 1 - 15

Status)

Note:

F

0h

-

F

E h

Chassisspecific

Drive

Slot

0Dh

Event Offset Triggers Contrib.

To

System

Status

Assert

/Deassert

Reada ble

Value/

Offset s fatal nc =

Degrad ed c =

Nonfatal

As and

De

Analo g

Event

Data

Rearm St an db y

R, T A

00 - Drive Presence

Sensor

Specifi c

6Fh

01- Drive Fault

07 - Rebuild/Remap in progress nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal nc =

Degrad ed c =

Nonfatal

OK

Degrad ed

As and

De

As and

De

As and

De

As and

De

As and

De

Degrad ed

As and

De

Analo g

Analo g

Analo g

Analo g

Analo g

R, T

R, T

R, T

R, T

R, T

Trig

Offset

A

A

A

A

A

A

X

238 Revision 2.0

Appendix B: Integrated BMC Sensor Tables

3. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply).

4. This is only applicable when the system does not support redundant fans. When fan redundancy is supported, then the contribution to system state is driven by the fan redundancy sensor.

Revision 2.0 239

Appendix C: POST Code Diagnostic LED Decoder

Appendix C: POST Code Diagnostic LED Decoder

As an aid to assist in trouble shooting a system hang that occurs during a system’s Power-On

Self Test (POST) process, the server board includes a bank of eight POST Code Diagnostic

LEDs on the back edge of the server board.

During the system boot process, Memory Reference Code (MRC) and System BIOS execute a number of memory initialization and platform configuration processes, each of which is assigned a specific hex POST code number. As each routine is started, the given POST code number is displayed to the POST Code Diagnostic LEDs on the back edge of the server board.

During a POST system hang, the displayed post code can be used to identify the last POST routine that was run prior to the error occurring, helping to isolate the possible cause of the hang condition.

Each POST code is represented by eight LEDs; four Green and four Amber. The POST codes are divided into two nibbles, an upper nibble and a lower nibble. The upper nibble bits are represented by Amber Diagnostic LEDs #4, #5, #6, #7. The lower nibble bits are represented by

Green Diagnostics LEDs #0, #1, #2 and #3. If the bit is set in the upper and lower nibbles, the corresponding LED is lit. If the bit is clear, the corresponding LED is off.

Figure 53. POST Code Diagnostic LEDs

In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The

LEDs are decoded as follows:

Note: Diag LEDs are best read and decoded when viewing the LEDs from the back of the system.

LEDs

Status

MSB

LED #7

8h

ON

Table 72. POST Progress Code LED Example

Upper Nibble AMBER LEDs

LED #6

4h

OFF

LED #5

2h

ON

LED #4

1h

OFF

LED #3

8h

ON

Lower Nibble GREEN LEDs

LED #2

4h

ON

LED #1

2h

OFF

LSB

LED #0

1h

OFF

240 Revision 2.0

Appendix C: POST Code Diagnostic LED Decoder

0

Results

1

Ah

0 1 0 1

Ch

1 0

Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as ACh

The following table provides a list of all POST progress codes.

Table 73. POST Progress Codes

05h

06h

07h

08h

09h

0Eh

0Fh

Checkpoint

Diagnostic LED Decoder

1 = LED On, 0 = LED Off

Upper Nibble Lower Nibble

MSB LSB

8h 4h 2h 1h 8h 4h 2h 1h

LED # #7 #6 #5 #4 #3 #2 #1 #0

SEC Phase

01h

02h

03h

04h

0

0

0

0

0

0

0

0

0

0

0

1

1

0

1

0

CRAM initialization begin

Pei Cache When Disabled

Description

0 0 0 0 0 0 0 1 First POST code after CPU reset

0 0 0 0 0 0 1 0 Microcode load begin

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

1

1

1

0

1

1

1

1

0

1

1

SEC Core At Power On Begin.

Early CPU initialization during Sec Phase.

Early SB initialization during Sec Phase.

0 0 0 0 1 0 0 0 Early NB initialization during Sec Phase.

0 0 0 0 1 0 0 1 End Of Sec Phase.

0 0 0 0 1 1 1 0 Microcode Not Found.

Microcode Not Loaded.

PEI Phase

10h

11h

15h

0 0 0 1 0 0 0 0 PEI Core

0 0 0 1 0 0 0 1 CPU PEIM

0 0 0 1 0 1 0 1 NB PEIM

19h 0 0 0 1 1 0 0 1 SB PEIM

MRC Process Codes

– MRC Progress Code Sequence is executed

PEI Phase continued…

31h 0 0 1 1 0 0 0 1 Memory Installed

32h

33h

34h

0 0 1 1 0 0 1 0 CPU PEIM (Cpu Init)

0 0 1 1 0 0 1 1 CPU PEIM (Cache Init)

0 0 1 1 0 1 0 0 CPU PEIM (BSP Select)

35h

36h

0

0

0

0

1

1

1

1

0

0

1

1

0

1

1

0

CPU PEIM (AP Init)

CPU PEIM (CPU SMM Init)

4Fh

DXE Phase

0 1 0 0 1 1 1 1 Dxe IPL started

60h

61h

62h

63h

68h

69h

6Ah

70h

0

0

0

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

1

0

1

0

DXE Core started

DXE NVRAM Init

SB RUN Init

0 1 1 0 0 0 1 1 Dxe CPU Init

0 1 1 0 1 0 0 0 DXE PCI Host Bridge Init

0

0

0

1

1

1

1

1

1

0

0

1

1

1

0

0

0

0

0

1

0

1

0

0

DXE NB Init

DXE NB SMM Init

DXE SB Init

Revision 2.0 241

Appendix C: POST Code Diagnostic LED Decoder

A5h

A6h

A7h

A8h

A9h

ABh

ACh

ADh

AEh

AFh

B0h

B1h

B2h

B3h

B4h

B5h

B6h

B7h

00h

9Bh

9Ch

9Dh

A1h

A2h

A3h

A4h

94h

95h

96h

97h

98h

99h

9Ah

78h

79h

90h

91h

92h

93h

Diagnostic LED Decoder

1 = LED On, 0 = LED Off

Checkpoint Upper Nibble

MSB

Lower Nibble

LSB

8h 4h 2h 1h 8h 4h 2h 1h

LED # #7 #6 #5 #4 #3 #2 #1 #0

71h 0 1 1 1 0 0 0 1 DXE SB SMM Init

72h 0 1 1 1 0 0 1 0 DXE SB devices Init

0

0

1

1

1

1

1

1

0

0

0

0

1

1

0

0

0

0

1

1

1

1

1

1

1

1

0

0

0

0

0

0

0

0

0

0

0

0

0

0

1

1

0

1

0

1

0

1

DXE ACPI Init

DXE CSM Init

DXE BDS Started

DXE BDS connect drivers

DXE PCI Bus begin

DXE PCI Bus HPC Init

Description

1 0 0 1 0 1 0 0 DXE PCI Bus enumeration

1 0 0 1 0 1 0 1 DXE PCI Bus resource requested

1 0 0 1 0 1 1 0 DXE PCI Bus assign resource

1 0 0 1 0 1 1 1 DXE CON_OUT connect

1 0 0 1 1 0 0 0 DXE CON_IN connect

1 0 0 1 1 0 0 1 DXE SIO Init

1 0 0 1 1 0 1 0 DXE USB start

1

1

1

0

0

0

0

1

1

1

1

1

1

0

0

0

1

1

1

0

0

1

0

1

DXE USB reset

1 0 0 1 1 1 0 0 DXE USB detect

1 0 0 1 1 1 0 1 DXE USB enable

1 0 1 0 0 0 0 1 DXE IDE begin

1 0 1 0 0 0 1 0 DXE IDE reset

1 0 1 0 0 0 1 1 DXE IDE detect

1 0 1 0 0 1 0 0 DXE IDE enable

1 0 1 0 0 1 0 1 DXE SCSI begin

1 0 1 0 0 1 1 0 DXE SCSI reset

1 0 1 0 0 1 1 1 DXE SCSI detect

1 0 1 0 1 0 0 0 DXE SCSI enable

1 0 1 0 1 0 0 1 DXE verifying SETUP password

1 0 1 0 1 0 1 1 DXE SETUP start

1 0 1 0 1 1 0 0 DXE SETUP input wait

1 0 1 0 1 1 0 1 DXE Ready to Boot

1 0 1 0 1 1 1 0 DXE Legacy Boot

1 0 1 0 1 1 1 1 DXE Exit Boot Services

1 0 1 1 0 0 0 0 RT Set Virtual Address Map Begin

1 0 1 1 0 0 0 1 RT Set Virtual Address Map End

1 0 1 1 0 0 1 0 DXE Legacy Option ROM init

1 0 1 1 0 0 1 1 DXE Reset system

DXE USB Hot plug

DXE PCI BUS Hot plug

1 0 1 1 0 1 1 0 DXE NVRAM cleanup

1 0 1 1 0 1 1 1 DXE Configuration Reset

0 0 0 0 0 0 0 0 INT19

242 Revision 2.0

Appendix C: POST Code Diagnostic LED Decoder

Diagnostic LED Decoder

1 = LED On, 0 = LED Off

Checkpoint Upper Nibble

MSB

Lower Nibble

LSB

8h 4h 2h 1h 8h 4h 2h 1h

LED # #7 #6 #5 #4 #3 #2 #1 #0

S3 Resume

E0h

Description

1 1 0 1 0 0 0 0 S3 Resume PEIM (S3 started)

E1h

E2h

1 1 0 1 0 0 0 1 S3 Resume PEIM (S3 boot script)

1 1 0 1 0 0 1 0 S3 Resume PEIM (S3 Video Repost)

E3h 1 1 0 1 0 0 1 1 S3 Resume PEIM (S3 OS wake)

BIOS Recovery

F0h

F1h

1 1 1 1 0 0 0 0 PEIM which detected forced Recovery condition

1 1 1 1 0 0 0 1 PEIM which detected User Recovery condition

F2h

F3h

F4h

1 1 1 1 0 0 1 0 Recovery PEIM (Recovery started)

1 1 1 1 0 0 1 1 Recovery PEIM (Capsule found)

1 1 1 1 0 1 0 0 Recovery PEIM (Capsule loaded)

POST Memory Initialization MRC Diagnostic Codes

There are two types of POST Diagnostic Codes displayed by the MRC during memory initialization; Progress Codes and Fatal Error Codes.

The MRC Progress Codes are displays to the Diagnostic LEDs that show the execution point in the MRC operational path at each step.

Table 74. MRC Progress Codes

B5h

B6h

B7h

B8h

B9h

B0h

B1h

B2h

B3h

B4h

BAh

BBh

BCh

Checkpoint

LED

MRC Progress Codes

Diagnostic LED Decoder

1 = LED On, 0 = LED Off

Upper Nibble

MSB

Lower Nibble

LSB

8h 4h 2h 1h 8h 4h 2h 1h

#7 #6 #5 #4 #3 #2 #1 #0

1

1 0 1 1 0 0 0 1 Set DDR3 frequency

1

1

1

1

1

1

1

1

0

Description

1 0 1 1 0 0 1 0 Gather remaining SPD data

0

0

0

1 0 1 1 0 1 1 0 Perform the JEDEC defined initialization sequence

1 0 1 1 0 1 1 1 Train DDR3 ranks

0

0

0

0

0

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

0

0

0

0

1

1

1

1

1

0

0

1

1

0

0

0

0

1

0

1

0

0

0

0

1

1

0

0

1

0

1

0

1

0

1

0

Detect DIMM population

Program registers on the memory controller level

Evaluate RAS modes and save rank information

Program registers on the channel level

Initialize CLTT/OLTT

Hardware memory test and init

Execute software memory init

Program memory map and interleaving

Program RAS configuration

Revision 2.0 243

Appendix C: POST Code Diagnostic LED Decoder

Checkpoint

BFh

LED

Diagnostic LED Decoder

1 = LED On, 0 = LED Off

Upper Nibble

MSB

Lower Nibble

LSB

8h 4h 2h 1h 8h 4h 2h 1h

#7 #6 #5 #4 #3 #2 #1 #0

1 0 1 1 1 1 1 1 MRC is done

Description

Memory Initialization at the beginning of POST includes multiple functions, including: discovery, channel training, validation that the DIMM population is acceptable and functional, initialization of the IMC and other hardware settings, and initialization of applicable RAS configurations.

When a major memory initialization error occurs and prevents the system from booting with data integrity, a beep code is generated, the MRC will display a fatal error code on the diagnostic

LEDs, and a system halt command is executed. Fatal MRC error halts do NOT change the state of the System Status LED, and they do NOT get logged as SEL events. The following table lists all MRC fatal errors that are displayed to the Diagnostic LEDs.

Table 75. POST Progress LED Codes

Diagnostic LED Decoder

1 = LED On, 0 = LED Off

Checkpoint Upper Nibble

MSB

Lower Nibble

LSB

8h 4h 2h 1h 8h 4h 2h 1h

LED #7 #6 #5 #4 #3 #2 #1 #0

MRC Fatal Error Codes

E8h

E9h

EAh

EBh

Description

1 1 1 0 1 0 0 0

1 1 1 0 1 0 0 1

1 1 1 0 1 0 1 0

1 1 1 0 1 0 1 1

No usable memory error

01h = No memory was detected from the SPD read, or invalid config that causes no operable memory.

02h = Memory DIMMs on all channels of all sockets are disabled due to hardware memtest error.

3h = No memory installed. All channels are disabled.

Memory is locked by Intel

®

Trusted Execution Technology and is inaccessible

DDR3 channel training error

01h = Error on read DQ/DQS (Data/Data Strobe) init

02h = Error on Receive Enable

3h = Error on Write Leveling

04h = Error on write DQ/DQS (Data/Data Strobe

Memory test failure

01h = Software memtest failure.

02h = Hardware memtest failed.

03h = Hardware Memtest failure in Lockstep Channel mode requiring a channel to be disabled. This is a fatal error which requires a reset and calling MRC with a different RAS mode to retry.

244 Revision 2.0

Appendix C: POST Code Diagnostic LED Decoder

Diagnostic LED Decoder

1 = LED On, 0 = LED Off

Checkpoint Upper Nibble

MSB

LED

EDh

Lower Nibble

LSB

8h 4h 2h 1h 8h 4h 2h 1h

#7 #6 #5 #4 #3 #2 #1 #0

EFh

1

1

1

1

1

1

0

0

1

1

1

1

0

1

1

1

Description

DIMM configuration population error

01h = Different DIMM types (UDIMM, RDIMM, LRDIMM) are detected installed in the system.

02h = Violation of DIMM population rules.

03h = The 3rd DIMM slot cannot be populated when QR DIMMs are installed.

04h = UDIMMs are not supported in the 3rd DIMM slot.

05h = Unsupported DIMM Voltage.

Indicates a CLTT table structure error

Revision 2.0 245

Appendix D: POST Code Errors

Appendix D: POST Code Errors

Most error conditions encountered during POST are reported using POST Error Codes. These codes represent specific failures, warnings, or are informational. POST Error Codes may be displayed in the Error Manager display screen, and are always logged to the System Event Log

(SEL). Logged events are available to System Management applications, including Remote and

Out of Band (OOB) management.

There are exception cases in early initialization where system resources are not adequately initialized for handling POST Error Code reporting. These cases are primarily Fatal Error conditions resulting from initialization of processors and memory, and they are handed by a

Diagnostic LED display with a system halt.

The following table lists the supported POST Error Codes. Each error code is assigned an error type which determines the action the BIOS will take when the error is encountered. Error types include Minor, Major, and Fatal. The BIOS action for each is defined as follows:

Minor: The error message is displayed on the screen or on the Error Manager screen, and an error is logged to the SEL. The system continues booting in a degraded state.

The user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error.

Major: The error message is displayed on the Error Manager screen, and an error is logged to the SEL. The POST Error Pause option setting in the BIOS setup determines whether the system pauses to the Error Manager for this type of error so the user can take immediate corrective action or the system continues booting.

Note: F or 0048 “Password check failed”, the system halts, and then after the next reset/reboot will displays the error code on the Error Manager screen.

Fatal: The system halts during post at a blank screen with the text

“Unrecoverable fatal

error found. System will not boot until the error is resolved” and “Press <F2> to

enter setup” The POST Error Pause option setting in the BIOS setup does not have any effect with this class of error.

When the operator presses the F2 key on the keyboard, the error message is displayed on the Error Manager screen, and an error is logged to the SEL with the error code. The system cannot boot unless the error is resolved. The user needs to replace the faulty part and restart the system.

Note: The POST error codes in the following table are common to all current generation Intel

® server platforms. Features present on a given server board/system will determine which of the listed error codes are supported.

Error Code

0012

0048

0140

0141

Table 76. POST Error Codes and Messages

Error Message

System RTC date/time not set

Password check failed

PCI component encountered a PERR error

PCI resource conflict

Response

Major

Major

Major

Major

246 Revision 2.0

8182

8183

8190

8198

8300

8305

83A0

83A1

84F2

84F3

84F4

84FF

8500

8501

8520

8521

8522

8523

8524

8525

8526

8132

8133

8160

8161

8162

8163

8170

8171

8172

8173

8180

8181

0196

0197

5220

5221

5224

8130

8131

Error Code

0146

0191

0192

0194

0195

Error Message

PCI out of resources error

Processor core/thread count mismatch detected

Processor cache size mismatch detected

Processor family mismatch detected

Processor Intel

®

QPI link frequencies unable to synchronize

Processor model mismatch detected

Processor frequencies unable to synchronize

BIOS Settings reset to default settings

Passwords cleared by jumper

Password clear jumper is Set

Processor 01 disabled

Processor 02 disabled

Processor 03 disabled

Processor 04 disabled

Processor 01 unable to apply microcode update

Processor 02 unable to apply microcode update

Processor 03 unable to apply microcode update

Processor 04 unable to apply microcode update

Processor 01 failed Self Test (BIST)

Processor 02 failed Self Test (BIST)

Processor 03 failed Self Test (BIST)

Processor 04 failed Self Test (BIST)

Processor 01 microcode update not found

Processor 02 microcode update not found

Processor 03 microcode update not found

Processor 04 microcode update not found

Watchdog timer failed on last boot

OS boot watchdog timer failure

Baseboard management controller failed self-test

Hot Swap Controller failure

Management Engine (ME) failed Self Test

Management Engine (ME) Failed to respond.

Baseboard management controller failed to respond

Baseboard management controller in update mode

Sensor data record empty

System event log full

Memory component could not be configured in the selected RAS mode

DIMM Population Error

DIMM_A1 failed test/initialization

DIMM_A2 failed test/initialization

DIMM_A3 failed test/initialization

DIMM_B1 failed test/initialization

DIMM_B2 failed test/initialization

DIMM_B3 failed test/initialization

DIMM_C1 failed test/initialization

Appendix D: POST Code Errors

Minor

Minor

Major

Major

Major

Major

Major

Major

Major

Major

Major

Minor

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Minor

Minor

Response

Major

Fatal

Fatal

Fatal

Fatal

Fatal

Fatal

Major

Major

Major

Major

Major

Revision 2.0 247

Appendix D: POST Code Errors

8533

8534

8535

8536

8537

8538

8539

853A

853B

853C

853D

853E

853F

(Go to

85C0)

8540

Error Code

8527

8528

8529

852A

852B

852C

852D

852E

852F

8530

8531

8532

8548

8549

854A

854B

854C

854D

854E

854F

8541

8542

8543

8544

8545

8546

8547

8550

8551

8552

DIMM_C2 failed test/initialization

Error Message

DIMM_C3 failed test/initialization

DIMM_D1 failed test/initialization

DIMM_D2 failed test/initialization

DIMM_D3 failed test/initialization

DIMM_E1 failed test/initialization

DIMM_E2 failed test/initialization

DIMM_E3 failed test/initialization

DIMM_F1 failed test/initialization

DIMM_F2 failed test/initialization

DIMM_F3 failed test/initialization

DIMM_G1 failed test/initialization

DIMM_G2 failed test/initialization

DIMM_G3 failed test/initialization

DIMM_H1 failed test/initialization

DIMM_H2 failed test/initialization

DIMM_H3 failed test/initialization

DIMM_I1 failed test/initialization

DIMM_I2 failed test/initialization

DIMM_I3 failed test/initialization

DIMM_J1 failed test/initialization

DIMM_J2 failed test/initialization

DIMM_J3 failed test/initialization

DIMM_K1 failed test/initialization

DIMM_K2 failed test/initialization

DIMM_A1 disabled

DIMM_A2 disabled

DIMM_A3 disabled

DIMM_B1 disabled

DIMM_B2 disabled

DIMM_B3 disabled

DIMM_C1 disabled

DIMM_C2 disabled

DIMM_C3 disabled

DIMM_D1 disabled

DIMM_D2 disabled

DIMM_D3 disabled

DIMM_E1 disabled

DIMM_E2 disabled

DIMM_E3 disabled

DIMM_F1 disabled

DIMM_F2 disabled

DIMM_F3 disabled

DIMM_G1 disabled

248

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Response

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Revision 2.0

8574

8575

8576

8577

8578

8579

857A

857B

857C

857D

857E

8568

8569

856A

856B

856C

856D

856E

8561

8562

8563

8564

8565

8566

8567

856F

8570

8571

8572

8573

Error Code

8553

8554

8555

8556

8557

8558

8559

855A

855B

855C

855D

855E

855F

(Go to

85D0)

8560

DIMM_G2 disabled

DIMM_G3 disabled

DIMM_H1 disabled

DIMM_H2 disabled

DIMM_H3 disabled

DIMM_I1 disabled

DIMM_I2 disabled

DIMM_I3 disabled

DIMM_J1 disabled

DIMM_J2 disabled

DIMM_J3 disabled

DIMM_K1 disabled

DIMM_K2 disabled

Error Message

DIMM_A1 encountered a Serial Presence Detection (SPD) failure

DIMM_A2 encountered a Serial Presence Detection (SPD) failure

DIMM_A3 encountered a Serial Presence Detection (SPD) failure

DIMM_B1 encountered a Serial Presence Detection (SPD) failure

DIMM_B2 encountered a Serial Presence Detection (SPD) failure

DIMM_B3 encountered a Serial Presence Detection (SPD) failure

DIMM_C1 encountered a Serial Presence Detection (SPD) failure

DIMM_C2 encountered a Serial Presence Detection (SPD) failure

DIMM_C3 encountered a Serial Presence Detection (SPD) failure

DIMM_D1 encountered a Serial Presence Detection (SPD) failure

DIMM_D2 encountered a Serial Presence Detection (SPD) failure

DIMM_D3 encountered a Serial Presence Detection (SPD) failure

DIMM_E1 encountered a Serial Presence Detection (SPD) failure

DIMM_E2 encountered a Serial Presence Detection (SPD) failure

DIMM_E3 encountered a Serial Presence Detection (SPD) failure

DIMM_F1 encountered a Serial Presence Detection (SPD) failure

DIMM_F2 encountered a Serial Presence Detection (SPD) failure

DIMM_F3 encountered a Serial Presence Detection (SPD) failure

DIMM_G1 encountered a Serial Presence Detection (SPD) failure

DIMM_G2 encountered a Serial Presence Detection (SPD) failure

DIMM_G3 encountered a Serial Presence Detection (SPD) failure

DIMM_H1 encountered a Serial Presence Detection (SPD) failure

DIMM_H2 encountered a Serial Presence Detection (SPD) failure

DIMM_H3 encountered a Serial Presence Detection (SPD) failure

DIMM_I1 encountered a Serial Presence Detection (SPD) failure

DIMM_I2 encountered a Serial Presence Detection (SPD) failure

DIMM_I3 encountered a Serial Presence Detection (SPD) failure

DIMM_J1 encountered a Serial Presence Detection (SPD) failure

DIMM_J2 encountered a Serial Presence Detection (SPD) failure

DIMM_J3 encountered a Serial Presence Detection (SPD) failure

DIMM_K1 encountered a Serial Presence Detection (SPD) failure

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Appendix D: POST Code Errors

Response

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Revision 2.0 249

Appendix D: POST Code Errors

85E0

85E1

85E2

85E3

85E4

85E5

85E6

85E7

85E8

85E9

85EA

85D4

85D5

85D6

85D7

85D8

85D9

85DA

85DB

85DC

85DD

85DE

85DF

85C5

85C6

85C7

85C8

85C9

85CA

85CB

85CC

85CD

85CE

85CF

85D0

85D1

85D2

85D3

Error Code

857F

(Go to

85E0)

85C0

85C1

85C2

85C3

85C4

Error Message

DIMM_K2 encountered a Serial Presence Detection (SPD) failure

DIMM_K3 failed test/initialization

DIMM_L1 failed test/initialization

DIMM_L2 failed test/initialization

DIMM_L3 failed test/initialization

DIMM_M1 failed test/initialization

DIMM_M2 failed test/initialization

DIMM_M3 failed test/initialization

DIMM_N1 failed test/initialization

DIMM_N2 failed test/initialization

DIMM_N3 failed test/initialization

DIMM_O1 failed test/initialization

DIMM_O2 failed test/initialization

DIMM_O3 failed test/initialization

DIMM_P1 failed test/initialization

DIMM_P2 failed test/initialization

DIMM_P3 failed test/initialization

DIMM_K3 disabled

DIMM_L1 disabled

DIMM_L2 disabled

DIMM_L3 disabled

DIMM_M1 disabled

DIMM_M2 disabled

DIMM_M3 disabled

DIMM_N1 disabled

DIMM_N2 disabled

DIMM_N3 disabled

DIMM_O1 disabled

DIMM_O2 disabled

DIMM_O3 disabled

DIMM_P1 disabled

DIMM_P2 disabled

DIMM_P3 disabled

DIMM_K3 encountered a Serial Presence Detection (SPD) failure

DIMM_L1 encountered a Serial Presence Detection (SPD) failure

DIMM_L2 encountered a Serial Presence Detection (SPD) failure

DIMM_L3 encountered a Serial Presence Detection (SPD) failure

DIMM_M1 encountered a Serial Presence Detection (SPD) failure

DIMM_M2 encountered a Serial Presence Detection (SPD) failure

DIMM_M3 encountered a Serial Presence Detection (SPD) failure

DIMM_N1 encountered a Serial Presence Detection (SPD) failure

DIMM_N2 encountered a Serial Presence Detection (SPD) failure

DIMM_N3 encountered a Serial Presence Detection (SPD) failure

DIMM_O1 encountered a Serial Presence Detection (SPD) failure

250

Response

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Major

Revision 2.0

Error Code

85EB

85EC

85ED

85EE

85EF

8604

8605

8606

92A3

92A9

A000

A001

A002

A003

A100

A421

A5A0

A5A1

A6A0

Error Message

DIMM_O2 encountered a Serial Presence Detection (SPD) failure

DIMM_O3 encountered a Serial Presence Detection (SPD) failure

DIMM_P1 encountered a Serial Presence Detection (SPD) failure

DIMM_P2 encountered a Serial Presence Detection (SPD) failure

DIMM_P3 encountered a Serial Presence Detection (SPD) failure

POST Reclaim of non-critical NVRAM variables

BIOS Settings are corrupted

NVRAM variable space was corrupted and has been reinitialized

Serial port component was not detected

Serial port component encountered a resource conflict error

TPM device not detected.

TPM device missing or not responding.

TPM device failure.

TPM device failed self test.

BIOS ACM Error

PCI component encountered a SERR error

PCI Express* component encountered a PERR error

PCI Express* component encountered an SERR error

DXE Boot Service driver: Not enough memory available to shadow a Legacy

Option ROM

Appendix D: POST Code Errors

Minor

Minor

Major

Fatal

Minor

Fatal

Minor

Response

Major

Major

Major

Major

Major

Minor

Major

Major

Major

Major

Minor

Minor

POST Error Beep Codes

The following table lists the POST error beep codes. Prior to system video initialization, the

BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user-visible code on the POST Progress LEDs.

Table 77. POST Error Beep Codes

1

3

2

Beeps

USB device action

1 long Intel

Error Message

®

TXT security violation

Memory error

POST Progress Code

NA

0xAE, 0xAF

Description

Short beep sounded whenever a USB device is discovered in POST, or inserted or removed during runtime

System halted because Intel

®

Trusted Execution

Technology detected a potential violation of system security.

See Tables 28 and 29 System halted because a fatal error related to the memory was detected.

NA Recovery boot has been initiated

4

BIOS Recovery started

BIOS Recovery failure

NA BIOS recovery has failed. This typically happens so quickly after recovery us initiated that it sounds like a 2-4 beep code.

The Integrated BMC may generate beep codes upon detection of failure conditions. Beep codes are sounded each time the problem is discovered, such as on each power-up attempt, but are not sounded continuously. Codes that are common across all Intel

®

server boards and systems that use same generation chipset are listed in the following table. Each digit in the code is represented by a sequence of beeps whose count is equal to the digit.

Revision 2.0 251

Appendix D: POST Code Errors

Table 78. Integrated BMC Beep Codes

Code

1-5-2-1

1-5-2-4

1-5-4-2

Reason for Beep

No CPUs installed or first CPU socket is empty.

1-5-4-4 Power control fault (power good assertion timeout).

1-5-1-2 VR Watchdog Timer sensor assertion

1-5-1-4

MSID Mismatch

Power fault

Power Supply Status

Associated Sensors

CPU1 socket is empty, or sockets are populated incorrectly

CPU1 must be populated before CPU2.

MSID mismatch occurs if a processor is installed into a system board that has incompatible power capabilities.

DC power unexpectedly lost (power good dropout)

– Power unit sensors report power unit failure offset

Power good assertion timeout

– Power unit sensors report soft power control failure offset

VR controller DC power on sequence was not completed in time.

The system does not power on or unexpectedly powers off and a Power Supply Unit (PSU) is present that is an incompatible model with one or more other PSUs in the system.

252 Revision 2.0

Appendix E: Supported Intel

®

The Intel

®

Server Board S1200V3RP requires a passive processor heat sink solution when integrated in the Intel

®

pedestal server chassis listed below. The Intel

®

Server Board

S1200V3RP supports up to 95W TDP Intel

®

Xeon

®

Processor.

Table 79. Compatible Intel

®

Intel

®

P4304XXSHDR

System Fans

Two Fixed Fans

Storage Drives

Four 3.5” Hotswap Drive Bay

Power Supply(s)

Two 460W CRPS

P4304XXSFDR Two Fixed Fans

Four 3.5” Fixed Drive Trays

Two 460W CRPS

You must install the active processor heat sink with the airflow direction as shown in the following figure.

Revision 2.0

Figure 54. Processor Heatsink Installation

253

Glossary

Glossary

DHCP

DIB

DPC

EEPROM

EMP

EPS

FML

FNI

FRB

FRU

FSB

FTM

GPIO

HSBP

HSC

I-cache

This appendix contains important terms used in the preceding chapters. For ease of use, numeric entries are listed first (for example, “82460GX”) with alpha entries following (for example, “AGP 4x”). Acronyms are then entered in their respective place, with non-acronyms following.

Term

ACPI

AES

AMB

APIC

ARP

ASF

ASIC

BIST

BMC

Bridge

BSP

CBC

CLI

CLTT

CMOS

CSR

D-cache

I

2

C

IA

Advanced Configuration and Power Interface

Definition

Advanced Encryption Standard

Advanced Memory Buffer (there is an AMB on each FBDIMM)

Advanced Programmable Interrupt Controller

Address Resolution Protocol

Alert Standards Forum

Application specific integrated circuit

Built-in self test

Baseboard management controller

Circuitry connecting one computer bus to another, allowing an agent on one to access the other.

Bootstrap processor

Chassis bridge controller. A microcontroller connected to one or more other CBCs. Together they bridge the IPMB buses of multiple chassis.

Command-line interface

Closed-loop thermal throttling (memory throttling mode)

In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes of memory on the server board.

Control and status register

Data cache. Processor-local cache dedicated for memory locations explicitly loaded and stored by running code.

Dynamic Host Configuration Protocol

Device Information Block

Direct Platform Control

Electrically erasable programmable read-only memory

Emergency management port

External Product Specification

Fast management link

Fast management link network interface

Fault resilient booting

Field replaceable unit

Front side bus

Firmware transfer mode

General-purpose input/output

Hot-swap backplane

Hot-swap controller

Instruction cache. Processor-local cache dedicated for memory locations retrieved through instruction fetch operations.

Inter-integrated circuit bus

Intel

®

architecture

254 Revision 2.0

Glossary

PEF

PET

PIA

PLD

POST

PROM

PSMI

PWM

RAM

RAS

RC4 ms

MUX

NIC

NMI

OBF

OEM

OLTT

PCI

PECI

LAN

LCD

LPC

LUN

MAC

MD5

MIB

IBF

Term

ICH

IERR

INIT

IPMB

IPMI

ITP

KCS

KT

KVM

RMCP+

ROM

RTC

SCI

SDR

Definition

Input buffer

I/O controller hub

Internal error

Initialization signal

Intelligent Platform Management Bus

Intelligent Platform Management Interface

In-target probe

Keyboard controller style

Keyboard text

Keyboard, video, and mouse

Local area network

Liquid crystal display

Low pin count

Logical unit number

Media Access Control

Message Digest 5. A hashing algorithm that provides higher security than MD2.

Modular information block. A descriptive text translation of a PET event, contained in a MIB file for use by an SNMP agent hen decoding SEL entries.

Millisecond

Multiplexer

Network interface card

Non-maskable interrupt

Output buffer

Original equipment manufacturer

Open-loop thermal throttling (memory throttling mode)

Peripheral Component Interconnect

Platform Environmental Control Interface

Platform event filtering

Platform event trap

Platform information area

Programmable logic device

Power-on self-test

Programmable read-only memory

Power Supply Management Interface

Pulse Width Modulation. The mechanism used to control the speed of system fans.

Random Access Memory

Reliability, availability, and serviceability

Rivest Cipher 4. A stream cipher designed by Rivest* for RSA data security, now RSA security. It is a variable key-size stream cipher with byte-oriented operations. The algorithm is based on a random permutation.

Remote Management Control Protocol

Read-only memory

Real-time clock

System Control Interrupt. A system interrupt used by hardware to notify the operating system of ACPI events.

Sensor data record

Revision 2.0 255

Glossary

Term

SDRAM

SEL

SHA1

SIO

SMBus*

SMI

SMM

SMS

SNMP

SOL

SPT

SRAM

UART

UDP

UHCI

VLAN

Definition

Synchronous dynamic random access memory

System event log

Secure Hash Algorithm 1

Server Input/Output

A two-wire interface based on the I

2

C protocol. The SMBus* is a low-speed bus that provides positive addressing for devices and bus arbitration.

Server management interrupt. SMI is the highest priority non-maskable interrupt.

Server management mode

Server management software

Simple Network Management Protocol

Serial-over-LAN

Straight pass-through

Static random access memory

Universal asynchronous receiver and transmitter

User Datagram Protocol

Universal Host Controller Interface

Virtual local area network

256 Revision 2.0

Reference Documents

Reference Documents

See the following documents for additional information:

Advanced Configuration and Power Interface Specification, Revision 5.0, http://www.acpi.info/ .

Intelligent Platform Management Bus Communications Protocol Specification, Version

1.0. 1998. Intel Corporation, Hewlett-Packard* Company, NEC* Corporation, Dell*

Computer Corporation.

Intelligent Platform Management Interface Specification, Version 2.0. 2004. Intel

Corporation, Hewlett-Packard* Company, NEC* Corporation, Dell* Computer

Corporation.

Platform Support for Serial-over-LAN (SOL), TMode, and Terminal Mode External

Architecture Specification, Version 1.1, 02/01/02, Intel Corporation.

Intel

®

Remote Management Module User’s Guide, Intel Corporation.

Alert Standard Format (ASF) Specification, Version 2.0, 23 April 2003, ©2000-2003,

Distributed Management Task Force, Inc., http://www.dmtf.org

.

BIOS for PCSD Platforms Based on Intel

®

Xeon Processor E3-1200 V3/V4 Product

Families External Product Specification

PCSD Platforms Based On Intel Xeon

®

Processor E3-1200 V3/V4 Product Families

BMC Core Firmware External Product Specification

Revision 2.0 257

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement

Table of contents