Installation splitters BESL 3-way splitters

Installation splitters
BESL 3-way splitters
• 3-way installation splitter
• Ingress Safe™ - unique passive ingress reduction technology
• High return loss and isolation performance
• CPD Safe™ - silver plated beryllium copper F-inner
spring
• F-inner spring accepts test gauges between 0.56
and 1.20 mm
• Compact housing with nickel plating
• Exceeds EN Class A screening requirements
Overview
Products within the BaseLine range are designed for easy
installation and have a compact, nickel plated housing.
All F-connectors used on BaseLine products meet SCTE
standards (ANSI SCTE 02 2006). Made of silver plated
beryllium copper, the F-inner spring is designed to connect
coax cables with an inner core of 0.56 to 1.30 mm. It
retains this elasticity and provides effective clamping force
even when varying thicknesses of inner conductor are
connected in succession.
The intermodulation performance, which is an important
factor in high level return path signals, has been greatly
improved through a newly developed ferrite and specially
designed circuits.
The housing has a soldered back lid for reliable ingress
and egress performance and protection against
moisture. The high frequency shielding exceeds Class A
requirements (EN-50083-2:2006) over the whole
frequency range from 5 MHz to 1000 MHz.
Dec/2011 - Version 1.1
Ingress Safe
Our patented Ingress Safe technology uses a phase
cancellation technique to considerably reduce ingress
created within the home. It has no adverse effect on the
CATV spectrum and is transparent to the forward and
reverse path signals.
• Significantly reduces noise on CATV networks,
improving network performance
• Field tests show Ingress Safe units in the distribution
network can deliver improvement in the carrier to noise
ratio that averages from between 3 dB and 12 dB,
depending on the network topology
• Prevents or delays the need to deploy technicians to
rectify faults caused by the cumulative effects of ingress
on network performance and customer service.
CPD Safe
CPD (Common Path Distortion) is well known for producing
signal interference on networks. It is caused by electrolytic
corrosion or the oxidisation of dissimilar metals when in
close contact. CPD Safe technology protects against
CPD.
• Removes a primary cause of CPD
• Reduces signal interference on the network
• Drives fewer reported faults
• Reduces truck rolls
• Improves customer service
Technetix Group Limited
e: sales@technetix.com w: www.technetix.com
Installation splitters
BESL 3-way splitters
Specifications
MHz
Insertion loss (dB)
Out 1
Out 2
Out 3
Return loss (dB, typ)
03
In to Out
All ports
Typ
Max
5-65
5.1
5.2
65-300
5.1
5.4
300-550
5.4
5.5
550-750
5.8
6.0
750-862
6.3
6.6
862-1006
6.3
7.3
5-65
5.2
5.3
65-300
5.3
5.5
300-550
5.5
5.6
550-750
5.8
6.0
750-862
6.4
6.7
862-1006
6.4
7.3
5-65
5.2
5.3
65-300
5.3
5.7
300-550
5.7
5.9
550-750
5.9
6.1
750-862
6.2
6.5
862-1006
6.2
7.0
5-15
30.0
15-550
29.8
550-1006
Isolation (dB)
Screening efficiency (dB)1
Shielding effectiveness (dBi)2
Ingress Safe
24.6
Out to Out
Out
Intermodulation p+q (dBc, min)3
Typ
Min
5-65
37.1 26.8
65-550
35.7 25.6
550-1006
31.9 22.8
5-300
>95
300-470
>90
470-950
>85
1
Tested according to EN 50083-2 2006
950-1000
>85
2
Tested according to SCTE IPS-TP-403
5-300
Avg 130
3
300-1000
Avg 120
Two carriers (50 & 55MHz),out to in, @ 120dBµV, after 10 pulses
(25V/1,2µS rise time/500µS duration) at all ports
-105
All ports
1 kV 1.2/50µs
Connectors
All ports
F-female
Material
Housing
Nickel plated zinc die cast
Silver plated beryllium copper
Impedance (Ohm, typ)
Dimensions (mm)
Equipment Approval
Two carriers (50 & 55MHz), out to in, @ 120dBµV, after 1 pulse 1KV
(1,2µS risetime/50µS fall time) at Input.
Port 2&3
Surge Class conformance4
F-spring
Remarks
4
Tested according to IEC 61000-4-5 2005
DC power blocking all ports
75
LxHxD
73.4x49.0x15.0
CE
Ordering information
Item Name
Article number
BESL-03
10930631
Measurements taken at room temperature
© Copyright 2011 Technetix Group Limited. All rights reserved.
This document is for information only. Features and specifications are subject to change without notice. Technetix, the Technetix logo, Ingress Safe, Modem Safe and certain other
marks and logos are trade marks or registered trade marks of Technetix Group Limited in the UK and certain other countries. Other brand and company names are trade marks of their
respective owners. Technetix protects its technology and designs by registering patents, trade marks and designs in Europe and certain other countries.
Dec/2011 - Version 1.1
Technetix Group Limited
e: sales@technetix.com w: www.technetix.com