S-S ERIES
S60 Top-of-Rack GbE Switch
Ultra-deep packet buffering and buffer allocation “tunability”
Non-blocking, line-rate switching performance
“JumpStart” bare metal auto-configuration functionality
48-port GbE switch with up to four 10 GbE ports in 1-RU
Optimized data center design supports redundant power
and fans, and front-to-back airflow
S-Series S60 Top-of-Rack GbE Switch
The Force10 S-Series S60 is the industry’s first GbE top-of-rack (ToR) switch purpose-built for increasing
network performance and lowering operational costs at the rack edge in highly virtualized data center
network environments. Equipped with ultra-deep packet buffering, buffer allocation “tunability” and
non-blocking, line-rate switching, the S60 eliminates the network congestion at the I/O associated with
heavy use of server virtualization as well as bursty streaming and storage applications.
Answering Data Center Challenges
The S60 was designed to answer the key ToR performance, configuration flexibility, power and cooling
efficiency, and reliability challenges. The scalable, compact S60 switch provides 48 GbE ports and up to
four optional 10 GbE uplinks in just 1-RU to conserve valuable rack space. In addition, the S60 introduces
the new “JumpStart” bare metal auto-configuration feature to simplify ToR switch provisioning and help
customers drive standardization in their data centers. The S60 design is also purpose-built for data center
operations, supporting front-to-back or back-to-front airflow, redundant hot-swappable power supplies and
fans, and low power consumption to reduce energy costs and increase reliability.
Key Features
• The 1-RU S60 switch delivers 48 access ports:
– 44 10/100/1000Base-T copper ports
– 4 GbE SFP ports
• Plus, the S60 provides two optional high-speed slots that support any of the following uplink modules:
– 2-port 10 GbE (LAN PHY, pluggable SFP+ modules)
– 2-port 12 Gbps stacking module
– 1-port 24 Gbps stacking module
• Ultra-deep packet buffering (1.25 GB) eliminates congestion associated with bursty multimedia and
storage applications
• Data center optimized design supports front-to-back airflow for hot/cold aisles, rear rack mounts, and
redundant hot-swappable AC or DC power and fans
• "JumpStart" bare-metal auto-configuration tool simplifies switch provisioning
• High-capacity 136 Gbps switch fabric delivers line-rate switching performance
• VirtualScale stacking technology enables up to 12 S60 switches to be managed as a single unit
• Modular FTOS with advanced monitoring and serviceability functions
• VirtualView provides real-time network and application traffic monitoring for virtualized data centers
• Open Automation-ready S60 design provides 2 GB of control path memory and 8 GB of control path
SD Flash
• Full complement of standards-based Layer 2, IPv4 and IPv6 features for unicast and multicast applications
• Supports 9,252 byte jumbo frames
• Designed for NEBS compliance
Specifications: S60 Top-of-Rack GbE Switch
Ordering Information
ORDER NUMBER
DESCRIPTION
S60-01-GE-48T
48-port 10/100/1000Base-T chassis
with four SFP ports, two modular slots,
one AC power supply, FTOS software
S60-01-10GE-2P
S60-01-12G-2S
S60-01-24G-1S
2-port 10 GbE SFP+ module
2-port 12 Gbps stacking module
1-port 24 Gbps stacking module
S60-01-SSC-12G
S60-01-LSC-12G
S60-01-SSC-24G
S60-01-LSC-24G
60 cm stacking cable for S60-01-12G-2S
4 m stacking cable for S60-01-12G-2S
60 cm stacking cable for S60-01-24G-1S
4 m stacking cable for S60-01-24G-1S
S60-PWR-AC
S60-PWR-DC
AC Power Supply Module
DC Power Entry Module
SW-SB-LATEST
Layer 3 FTOS software upgrade
Physical
44 line-rate 10/100/1000Base-T ports
4 GbE SFP ports
1 RJ45 console/management port with RS232 signaling
Optional uplink modules:
2 line-rate ports 10 Gigabit Ethernet SFP+
2 line-rate ports 12 Gigabit Stacking
1 line-rate port 24 Gigabit Stacking
802.1X Network Access Control
802.3ab Gigabit Ethernet (1000BASE-T)
802.3ac Frame Extensions for VLAN Tagging
802.3ad Link Aggregation with LACP
802.3ae 10 Gigabit Ethernet (10GBASE-X)
802.3ak 10 Gigabit Ethernet (10GBASE-CX4)
802.3i
Ethernet (10BASE-T)
802.3u
Fast Ethernet (100BASE-TX)
802.3x
Flow Control
802.3z
Gigabit Ethernet (1000BASE-X)
ANSI/TIA-1057
LLDP-MED
Force10 PVST+
MTU
9,252 bytes
RFC and I-D Compliance
General Internet Protocols
768
793
854
959
UDP
TCP
Telnet
FTP
1321
1350
2474
3164
MD5
TFTP
Differentiated Services
Syslog
1812
1858
2131
2338
3021
3046
3069
3128
Routers
IP Fragment Filtering
DHCP (relay)
VRRP
31-bit Prefixes
DHCP Option 82
Private VLAN
Tiny Fragment Attack
Protection
Path MTU Discovery
(partial)
IPv6
Neighbor Discovery
(partial)
Stateless Address
Autoconfiguration
(partial)
2463
2464
2675
3587
4291
ICMPv6
Ethernet Transmission
Jumbograms
Global Unicast
Address Format
Addressing
RIPv1
2453
RIPv2
MD5
NSSA
OSPFv2
Opaque LSA
3623
4222
Graceful Restart
Prioritization and
Congestion Avoidance
General IPv4 Protocols
791
792
826
1027
1035
1042
1191
1305
1519
1542
IPv4
ICMP
ARP
Proxy ARP
DNS (client)
Ethernet Transmission
Path MTU Discovery
NTPv3
CIDR
BOOTP (relay)
General IPv6 Protocols
Size: 1 RU, 1.7 h x 17.32 w x 16.73" d (4.3 h x 44 w x 42.5 cm d)
Weight: 14.39 lbs (6.54 kg)
ISO 7779 A-weighted sound pressure level:
59.6 dBA at 73.4°F (23°C)
Power supply: 100–240 VAC 50/60 Hz, –44 to -60 VDC
Max. thermal output: 531 BTU/h
Max. current draw per system:
2 A at 100/120 VAC, 1 A at 200/240 VAC, 3.6 A at -48 VDC
Max. power consumption: 156 W
Max. operating specifications:
Operating temperature: 32° to 122°F (0° to 50°C)
Operating humidity: 10 to 85% (RH), non-condensing
Max. non-operating specifications:
Storage temperature: –40° to 158°F (–40° to 70°C)
Storage humidity: 5 to 95% (RH), non-condensing
Reliability: MTBF 169,315 hours
1981
Redundancy
1997 Communities
2385 MD5
2439 Route Flap Damping
2796 Route Reflection
2842 Capabilities
2858 Multiprotocol Extensions
2918 Route Refresh
3065 Confederations
4360 Extended Communities
4893 4-byte ASN
5396 4-byte ASN representations
draft-ietf-idr-bgp4-20 BGPv4
draft-ietf-idr-restart-06 Graceful Restart
draft-michaelson-4byte-as-representation-05
4-byte ASN Representation (partial)
Ring stacking topology with dynamic master election
Dual modular slots with up to four 10 GbE ports
Link aggregation across stack members
Hot swappable redundant AC or DC power
Hot swappable redundant fans
Performance
MAC addresses:
IPv4 routes:
IPv6 routes:
Switch fabric capacity:
Link aggregation:
Stacking capacity:
Queues per port:
VLANs:
Line-rate Layer 2 switching:
Line-rate Layer 3 routing:
LAG load balancing:
Switching latency:
32K
16K
8K
136 Gbps
8 links per group, 128 groups per stack
96 Gbps per stack member
4 queues
1024 VLANs with 4096 tag value support
all protocols, including IPv4 and IPv6
IPv4 and IPv6
based on Layer 2, IPv4 or IPv6 headers
<10 µs for 64 byte frames
IEEE Compliance
802.1AB
802.1ag
802.1D
802.1p
802.1Q
802.1s
802.1w
LLDP
Connectivity fault Management
Bridging, STP
L2 Prioritization
VLAN Tagging, Double VLAN Tagging, GVRP
MSTP
RSTP
2460
2461
2462
RIP
1058
OSPF
2154
1587
2328
2370
Regulatory Compliance
Safety
BGP
UL/CSA 60950-1, 1st Edition
EN 60950-1, 1st Edition
IEC 60950-1, 1st Edition Including all National Deviations
and Group Differences
EN 60825-1 Safety of Laser Products Part 1: Equipment
Classification Requirements and User's Guide
EN 60825-2 Safety of Laser Products Part 2: Safety of
Optical Fibre Communication Systems
FDA Regulation 21 CFR 1040.10 and 1040.11
Emissions
Australia/New Zealand: AS/NZS CISPR 22: 2006, Class A
Canada: ICES-003, Issue-4, Class A
Europe: EN 55022: 2006 (CISPR 22: 2006), Class A
Japan: VCCI V3/2007.04 Class A
USA: FCC CFR 47 Part 15, Subpart B, Class A
Multicast
3569
1112 IGMPv1
4541
2236 IGMPv2
3376 IGMPv3
draft-ietf-pim-sm-v2-new-05 PIM-SM
SSM for IPv4
IGMPv1/v2 Snooping
Network Management
1155
1156
1157
1212
1215
1493
1850
1901
2011 IP MIB
2012 TCP MIB
2013 UDP MIB
2024 DLSw MIB
2096 IP Forwarding Table MIB
2570 SNMPv3
2571 Management Frameworks
2572 Message Processing and Dispatching
2574 SNMPv3 USM
2575 SNMPv3 VACM
2576 Coexistence Between SNMPv1/v2/v3
2578 SMIv2
2579 Textual Conventions for SMIv2
2580 Conformance Statements for SMIv2
2618 RADIUS Authentication MIB
2665 Ethernet-like Interfaces MIB
2674 Extended Bridge MIB
2787 VRRP MIB
2819 RMON MIB (groups 1, 2, 3, 9)
2863 Interfaces MIB
2865 RADIUS
3273 RMON High Capacity MIB
3416 SNMPv2
3418 SNMP MIB
3434 RMON High Capacity Alarm MIB
3580 802.1X with RADIUS
5060 PIM MIB
ANSI/TIA-1057
LLDP-MED MIB
draft-grant-tacacs-02
TACACS+
draft-ietf-idr-bgp4-mib-06 BGP MIBv1
IEEE 802.1AB
LLDP MIB
IEEE 802.1AB
LLDP DOT1 MIB
IEEE 802.1AB
LLDP DOT3 MIB
ruzin-mstp-mib-02
MSTP MIB (traps)
sFlow.org
sFlowv5
sFlow.org
sFlowv5 MIB (version 1.3)
FORCE10-BGP4-V2-MIB Force10 BGP MIB
(draft-ietf-idr-bgp4-mibv2-05)
FORCE10-IF-EXTENSION-MIB
FORCE10-LINKAGG-MIB
FORCE10-COPY-CONFIG-MIB
FORCE10-MON-MIB
FORCE10-PRODUCTS-MIB
FORCE10-SS-CHASSIS-MIB
FORCE10-SMI
FORCE10-SYSTEM-COMPONENT-MIB
FORCE10-TC-MIB
FORCE10-TRAP-ALARM-MIB
SMIv1
Internet MIB
SNMPv1
Concise MIB Definitions
SNMP Traps
Bridges MIB
OSPFv2 MIB
Community-based SNMPv2
Force10 Networks, Inc.
350 Holger Way
San Jose, CA 95134 USA
www.force10networks.com
408-571-3500
408-571-3550
PHONE
FACSIMILE
Immunity
EN 300 386 V1.3.3: 2005 EMC for Network Equipment
EN 55024: 1998 + A1: 2001 + A2: 2003
EN 61000-3-2: Harmonic Current Emissions
EN 61000-3-3: Voltage Fluctuations and Flicker
EN 61000-4-2: ESD
EN 61000-4-3: Radiated Immunity
EN 61000-4-4: EFT
EN 61000-4-5: Surge
EN 61000-4-6: Low Frequency Conducted Immunity
RoHS
All S-Series components are EU RoHS compliant.
© 2010 Force10 Networks, Inc. All rights reserved. Force10 Networks, Adit,
E-Series, Traverse, and TraverseEdge are registered trademarks and Axxius,
C-Series, ExaScale, FTOS, MASTERseries, P-Series, S-Series, TeraScale, and
TransAccess are trademarks of Force10 Networks, Inc. All other company names
are trademarks of their respective holders. Information in this document is subject
to change without notice. Certain features may not yet be generally available.
Force10 Networks, Inc. assumes no responsibility for any errors that may appear
in this document.
SSDS06