CASE: APPLICANT: LOCATION: REQUESTED ACTION: CEQA: EXISTING APPROVALS: ZONING: REQUIRED FINDINGS: ATTACHMENTS: STALL COMMENTS: B( . .~D OF ADJUSTMENT/DESIGN REVI:.. BOARD PROJECT OVERVIEW DESIGN REVIEW 17-2501 JCL & Sons, Agent (714) 642-6836 jclweatherman @ yahoo.com MJP Three Arch Llc 32322 Coast Highway APN 056-211-28 The applicant requests design review to replace four (4) rooftop air conditioning unit condensers in the Local Business Professional (LBP) zone. In accordance with California Environmental Quality Act guidelines, the project is categorically exempt pursuant to Section 15303, Class 3(e) (New Construction) which allows construction of new accessory (appurtenant) structures including garages, carports, patios, swimming pools, and fences. DR99-04: The Design Review Board granted approval for exterior modifications to a commercial building (April 29, 19993. DR99-126: Design Review Board approval was granted for signage (June 17, 1999). CUP 16-1349: Planning Commission approval was granted to establish and operate a medical day spa (July 6, 2016). Laguna Beach Professional (LBP) Zone Site Constraints: VHFHSZ РЕВ [$25.05.040(Н)] PI Aerial Map/Oblique/Site Photo XI Staking Plan and AC Manufacturer Specifications The request has been deferred to the Design Review Board because concerns were expressed with regard to location of the air conditioning units and view preservation of existing landscaping from the adjacent neighbor to the north. Zoning Plan Check Clearance Date: 11/8/2017 By: MAF 32322 Coast Hwy 20 ft @lyMade by YORK, Model:D3NZ036N05625NXA 542 :Made by Carrier, Model:48ESNA 240404030 *3: Made by York: This unit will not be replaced #4 Made by Carrier, Model:48ESNA240404030 seu Ni #5: Made by Carrier: This unit will not be replaced H#6/Made by YORK, Model:D3NZ036N03606NXA | ACH “a YORK | | - TECHNICAL GUIDE | 0 8 SINGLE PACKAGE | AIR CONDITIONER / GAS HEAT 14 SEER - R-410A - 3 PHASE 3 THRU 5 NOMINAL TONS - 208/230V 50 THRU 125 MBH HEAT INPUT MODELS: PCG4*36 THRU 60 AMERICAN as * TTT al QUALITY © ©) АЯ ко ны РНЕ СА => Certified Quality i SR Management System Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.york.com Additional rating information can be found at: www.ahridirectory.org WARRANTY SUMMARY" Standard 1-Year limited parts warranty Standard 5-Years limited compressor warranty. Lifetime gas heat exchanger warranty with registration See limited warranty certificate in User's Information Manual for details 5006143-Y TG-F-1017 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES VE г) Operating Efficiency - All PCG4 model gas units provide a \ | k-" minimum AFUE of 81.0% in heating and 14.0 SEER, 11.0 EER rating for cooling operation. All models meet California Low+Nox requirements of 40 ng/joule emission level for Air Quality Management Districts. *. On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexi- bility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibil- ity with less inventory. + Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified vía computers during assembly. Vital run test statistics such as system pressure, motor cur- rents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low craw! spaces without transition pieces. - Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed elec- trical disconnect switch must be installed - Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. - Condensate Pan - A corrosion-resistant, long-lasting, water- tight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 62- 89 standards (Ventilation for Acceptable Indoor Air Quality) « Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal - Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protec- tion. The pre-treated galvanized steel provides a better paint- to-steel bond, which resists corrosion and rust creep. Pow- der paint finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested) Continued on next page. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 5006143-YTG-F-1017 - Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an over- head crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each comer. More Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider vari- ety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. lsolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. This design strategi- cally places embossments in the pan for optimum strength and rigidity. Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and pro- vide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. Simple Control Circuit - A low voltage gas heat printed cir- cuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-n- lock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. Protected Compressor - The compressor is internally pro- tected against high pressure and temperature. This is accomplished by the simultaneous operation of high pres- sure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durabil- ity and efficient operation. Indoor coils use tin-coated copper tubing with aluminum fins for effective heat transfer. Heat Exchangers - Gas heat exchangers use corrosion- resistant, stainless-steel tubular construction to provide long- life, trouble-free operation. Gas heat exchangers are offered with lifetime warranties as standard with registration. Post Purge Induced Draft Combustion - Exhausts com- bustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable, durable and eliminates nui- sance lockouts. Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These burners are constructed of high-grade corrosion-resistant, aluminized steel. Low Maintenance - Long life, permanently lubricated out- door and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. Remov- ing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. Replacement Parts - The installer requires no special train- ing to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. Filter Frame Kit - All 3 phase units include a filter frame kit, which is shipped inside the unit from production. Field instal- lation is required. Filters - All 3 phase units include an applicable number of 1" washable filters, which are shipped inside the unit from pro- duction. Field installation is required. Two filters are required for A base units. Three filters are required for B base units. Johnson Controls Unitary Products 5006143-YTG-F-1017 NOMENCLATURE 1 2 3 4 5 6 7 8 9 1. Model Family 5. Gas Heating Input BTU/Hr x 1000 PCG - packaged A/C with gas heat, 050 = 50,000 BTU/Hr. input, blank = electric heat PCE - packaged A/C with electric heat, 6. Voltage-Phase-Frequency PHE - packaged heat pump with electric heat 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 2. Nominal Cooling Efficiency 7. NOx Approval 4 = 14 SEER, 6 = 16 SEER, elc. X = low-NOx, blank = not low-Nox 3. Cabinet Size 8. Generation Level A = small 35 x 51, B = large 45 x 51 1 = first generation 4. Nominal Air Conditioning Cooling Capacity 9. Revision Level 24 = Nominal Capacity, etc. A = original release, B = second release Examples: PCG4B421002X 1A is a packaged A/C with gas heat, 14 SEER, 3-1/2 ton, large cabinet, three-stage heat, 100,000 BTU gas heat, 230 volt, three phase, low-NOx model (first generation, first release) COMPONENT LOCATION — FAN MOTOR OUTDOOR FAN — COIL GUARD PANEL OUTDOOR COIL (Behind Panel) CONTROL BOARD TRANSFORMER HIGH VOLTAGE CONTACTOR PRESSURE SWITCH DRAFT INDUCER BLOWER GAS VALVE BLOWER MOTOR TXV INDOOR COIL INDOOR BLOWER COMPRESSOR GAS HEAT EXCHANGER REMOVABLE BASE RAILS BURNER ASSEMBLY UNIT LIMITATIONS Unit Limitations Model Unit Voitage Applied Voltage Outdoor DB Temp Min Max Max (°F) PCG4A36 208/230-3-60 187 252 125 PCG4A42 208/230-3-60 187 252 125 PCG4B48 208/230-3-60 187 252 125 PCG4B60 208/230-3-60 187 252 125 Johnson Controls Unitary Products 5006143-YTG-F-1017 ACCESSORIES Propane Conversion Kit (S1-1NP0703, S1-1NP0704) - Kit includes burner orifices, gas valve conversion and installa- tion instructions necessary to field convert unit from natural gas to propane. Economizer for Downflow Applications (S1-2EE04710024, S1-2EE04710124) - Modulating inte- grated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. Economizer for Horizontal Applications (S1-2EE04710224, S1-2EE04710324) - Modulating inte- grated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. Single/Dual Enthalpy Sensor (S1-HE-6863-0N00WS) - Sensor replaces dry bulb sensor standard in economizer kit. Provides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. Duct/Unit Mount CO2 Kit (S1-2AQ04700924) - Sensor kit detects CO? levels automatically and overrides the econo- mizer when CO2 levels rise above the preset limits. Wall Mount CO2 Kit (S1-2AQ04701024) - Sensor kit detects CO2 levels automatically and overrides the econo- mizer when CO2 levels rise above the preset limits. Supply Air Temperature Sensor Kit (S1-TE-63616E-2D) - Outdoor supply air temperature sensor kit used with econo- mizers. Filter/Frame Kit (Kit provided) (S1-1FF0602, S1-1FF0601) - Kit contains the necessary hardware to field install return air filters into the base unit. The filter rack is suitable for either 1" or 2" filters. Filter (S1-02647812000) - Washable 1” filter. Two filters are required for A base units. Three filters are required for B base units. Washable filters are included inside shipped units for field installation. Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. Loss of Charge Switch (S1-2LC00024) - Kit provides Loss of Charge sensor and wiring to provide safe shutdown of compressor. Rectangle to Round (Horizontal) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12° round for the 1AK0110 kit and from rectangle to 14" round for the 1AKO111 kit. Rectangle to Round (Downflow) Adapter (S1-1AK0108, S1-1AK0109) - Kit includes one supply and one retum air rectangle to round duct adapter. Adapters are preformed and designed to fit into current downflow duct openings on the roof curb. Transition is from rectangle to 16" round for the 1AK0108 kit and from rectangle to 18" round for the 1AK0109 kit. Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembied through hinge pins in each comer. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 14 inch high roof curbs. Transition Curb Kits (S1-1TC01*) - Adapter kits to allow field use of pre-existing installed roof curbs to match PCG4 footprint to Affinity roof curbs, Carrier, Trane, or Goodman curb footprints. Curb adapters are optional for current gener- ation Carrier replacements but are recommended for previ- ous generation applications. Refer to the PCG4 price pages for more details. Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) - Provides 0% through 50% outdoor air capability (field adjust- able). Designed for duct mounted side supply/return applica- tions. Includes hood and screen assembly. Thermostat (S51-THXU280") - Compatible thermostat con- trois are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with the York Hx™ Touchscreen Thermostat (S1-THXU280") available through Source1. For more information, see the thermostat section of the Product Equipment Catalog. Wall Thermostat - The units are designed to operate with standard, 24-volt electronic and electro-mechanical thermo- stats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. Low Ambient Kit (S1-2LA04701024) - Kit provides neces- sary hardware to convert unit to operate in cooling cycle down to 0° F. Standard unit operation 45° F. Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides nec- essary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. Johnson Controls Unitary Products GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. Package units give you the flexibility and choices you need in today’s market. These packaged cooling/ heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. The single-stage gas fired heaters have stainless steel tubular heat exchangers and spark to burner ignition. They are available in natural gas with field conversion to propane. RESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heating units, designed for outdoor installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for supply/ return or horizontal supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed and classified to ANSI Z21 47/CAN/ CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of G-90 galvanized, powder- painted steel, certified at 1000 hours salt spray test per ASTM- B117 standards. The unit top shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted outdoor coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil-faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24” O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPT female ridged mount connection. Indoor Blower Assembly - Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Johnson Controls Unitary Products 5006143-YTG-F-1017 Outdoor Fan Assembly - The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally pro- tected with internal high-pressure relief and over tempera- ture protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to mini- mize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Indoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced tin-coated cop- per tubes with all joints brazed. b. Indoor coil shall be of the direct expansion, draw through design. c. Outdoor coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. d. Outdoor coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXV's) shall be factory mounted and provided. b. Filter/strainer to eliminate any foreign matter. GAS HEATING SECTION Heat exchanger and exhaust system shall be constructed of corrosion-resistant materials and shall be designed with induced draft combustion with post purge logic and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40°F. Burners shall be of the in-shot type, constructed of aluminumized steel. All gas piping shall enter the unit cabinet at a single location through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of indoor fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary high-temperature limit switch. b. Induced draft pressure switch. c. Flame roll out switch(s) (manual reset). d. Flame proving controls. All gas heat models will meet the California requirement for emissions of less than 40 nanograms per Joule. 5006143-YTG-F-1017 PHYSICAL DATA A A B B so as not to ters. For internal filter use, a filter rack kit is included with all three phase models. Consult the instructions with that kit for filter sizes. Filter sizes: A=20x20, B=20x30. 6 Johnson Controls Unitary Products 5006143-YTG-F-1017 COOLING PERFORMANCE DATA - 3 TON PACKAGED UNIT MODEL NO. | PCG4A36 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 45.3 | 48.1 | 480 | 53.1 | 54.6 | 42.2 | 46.3 | 46.2 | 51.3 | 53.5 | 39.2 | 44.6 | 44.5 | 49.5 | 52.4 55/45 S.C. 45.3 | 432 | 36.0 | 36.5 | 27.9 | 42.2 | 39.5 | 33.3 | 334 | 26.1 | 39.2 | 35.8 | 30.6 | 30.4 | 244 K.W. 2.15 | 2.16 | 2.16 | 2.15 | 2.15 | 2.07 | 2.07 | 2.07 | 2.06 | 2.05 | 1.99 | 1.99 | 1.99 | 1.97 | 1.95 T.C. 42.0 | 437 | 438 | 48.6 | 524 | 39.4 | 42.5 | 424 | 47.1 | 51.0 | 36.8 | 41.2 | 41.0 | 45.6 495 65/55 S.C. 42.0 | 40.3 | 34.1 | 345 | 26.6 | 39.4 | 36.9 | 31.3 | 31.5 | 24.9 | 36.8 | 33.5 | 28.6 | 28.5 | 23.1 K.W. 239 | 241 | 240 | 241 | 240 | 2.30 | 2.31 | 2.31 | 2.32 | 2.31 | 2.20 | 2.22 | 2.22 | 2.22 | 2.21 T.C. 38.7 | 39.31 396 | 44.1 | 50.1 | 36.6 | 38.6 | 38.5 | 42.9 | 48.4 | 34.5 | 37.9 | 37.4 | 41.7 | 46.7 75163 S.C. 38.7 | 37.4 | 32.1 | 324 | 25.4 | 36.6 | 34.3 | 29.3 | 295 | 23.6 | 34.5 | 31.1 | 26.6 | 26.7 21.8 K.W. 263 | 2.66 | 2.64 | 2.67 | 2.65 | 2.52 | 2.55 | 2.54 | 2.57 | 2.56 | 2.41 | 2.45 | 2.44 | 2.47 | 2.46 T.C. 35.3 | 35.4 | 35.5 | 39.4 | 45.0 | 33.6 | 34.8 | 34.8 | 38.7 | 43.8 | 31.9 | 34.2 | 34.0 | 38.0 | 42.7 85/69 S.C. 35.3 | 34.4 | 30.0 | 30.1 | 23.6 | 33.6 | 32.0 | 275 | 275 | 21.9 | 31.9 | 29.5 | 25.0 | 25.0 | 20.2 K.W. 2.87 | 290 | 288 | 2.93 | 293 | 275 | 279 | 2.77 | 2.83 | 2.83 | 2.64 | 2.68 | 2.67 | 2.72 | 2.73 T.C. 31.9 | 31.5 | 315 | 34.8 | 39.8 | 30.5 | 31.0 | 31.0 | 34.6 | 39.2 | 29.2 | 30.5 | 30.6 | 34.3 | 38.6 95/75 S.C. 31.9 | 31.5 | 28.0 27.8 | 21.8 | 30.5 | 297 | 25.7 | 25.5 | 20.2 | 29.2 | 27.9 | 23.4 | 23.3 | 18.7 K.W. 3.11 | 3.14 | 3.12 | 3.20 | 3.21 | 2.99 | 3.02 | 3.00 | 3.08 | 3.10 | 2.87 | 2.91 | 2.89 | 2.97 | 2.99 T.C. 26.5 | 26.8 | 26.3 | 29.0 | 33.7 | 26.0 | 26.5 | 26.2 | 29.1 | 33.5 | 25.5 | 26.3 | 26.0 | 29.2 | 334 105 / 83 S.C. 26.5 | 26.8 | 24.0 | 24.4 | 193 | 26.0 | 25.7 | 22.6 | 22.8 | 18.0 | 25.5 | 24.5 | 21.2 | 21.3 | 16.7 K.W. 3.43 | 3.39 | 3.35 | 3.43 | 3.48 | 3.27 | 3.27 | 3.23 | 3.32 | 3.37 | 3.11 | 3.14 | 3.11 | 3.20 | 3.25 T.C. 21.4 | 223 | 21.3 | 234 | 27.7 | 21.6 | 22.2 | 21.4 | 238 | 28.0 | 21.8 | 22.2 | 21.5 | 24.2 | 28.3 115/89 S.C. 21.4 | 22.3 | 20.2 | 21.1 | 17.0 | 21.6 | 21.8 | 197 | 20.2 | 15.9 | 21.8 | 21.3 | 191 | 193 | 14.8 K.W. 3.74 | 3.65 | 357 | 367 | 375 | 354 | 350 | 344 | 3.54 | 3.63 | 3.34 | 3.36 | 3.32 | 3.42 | 3.50 T.C. 16.2 | 177 | 16.3 | 17.7 | 21.7 | 17.2 | 17.9 | 16.7 | 185 | 225 | 18.2 | 18.0 | 17.0 | 19.2 | 23.2 125/95 S.C. 16.2 | 17.7 | 16.3 | 17.7 | 14.6 | 17.2 | 17.9 | 16.7 | 17.6 | 13.8 | 18.2 | 18.0 | 17.0 | 17.4 13.0 K.W. 4.05 | 3.90 | 3.79 | 3.90 | 4.01 | 3.81 | 3.74 | 3.66 | 3.77 | 3.88 | 3.57 | 3.58 | 3.53 | 3.65 | 3.76 COOLING PERFORMANCE DATA - 3.5 TON PACKAGED UNIT MODEL NO. | PCG4A42 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 49.4 | 50.2 | 50.2 1 55.5 | 61.9 | 46.5 | 48.6 | 48.5 | 53.7 | 59.6 | 43.7 | 46.9 | 46.8 | 51.8 | 57.3 55/45 S.C. 47.8 | 45.0 | 38.5 | 39.6 | 32.6 | 45.5 | 42.1 | 36.2 | 37.0 | 30.7 | 43.1 | 39.2 | 33.9 | 34.4 | 28.7 K.W. 2.50 | 2.52 | 2.51 | 2.53 | 2.56 | 2.42 | 2.44 | 2.43 | 2.45 | 2.47 | 2.35 | 2.36 | 2.36 | 2.38 | 2.38 TC. 46.6 | 47.0 | 47.0 | 52.1 | 58.0 | 44.4 | 45.6 | 45.6 | 50.5 | 56.1 | 42.2 | 44.1 | 44.1 | 48.9 | 54.1 65 / 55 S.C. 45.5 | 43.2 | 36.4 | 37.7 | 30.8 43.7 | 40.5 | 34.4 | 35.3 | 29.2 | 41.9 | 37.7 | 32.5 | 32.8 | 27.5 KW. 2.73 | 2.76 | 2.74 | 2.77 | 2.80 | 2.55 | 2.68 | 2.66 | 2.70 | 2.71 | 2.36 | 2.61 | 2.59 | 2.62 | 2.61 T.C. 43.8 | 43.9 | 43.7 | 48.7 | 54.1 | 42.2 | 42.6 | 426 | 47.4 | 52.5 | 40.6 | 41.3 | 41.4 | 46.0 | 51.0 75163 S.C. 43.3 | 41.4 | 34.3 | 35.9 | 29.0 | 41.9 | 38.8 | 32.7 | 33.6 | 27.6 | 40.6 | 36.3 | 31.0 | 31.3 | 26.2 K.W. 2.97 | 3.00 | 2.97 | 3.01 | 3.04 | 2.67 | 2.93 | 2.89 | 2.94 | 2.94 | 2.38 | 2.86 | 2.82 | 2.87 | 2.84 T.C. 40.7 | 41.8 | 40.1 | 44.9 | 50.0 | 39.3 | 40.0 | 39.3 | 43.8 | 48.8 | 38.01 38.2 | 38.4 | 42.7 | 47.6 85/69 S.C. 40.4 | 37.7 | 32.8 | 33.9 | 27.3 | 39.2 | 36.1 | 31.0 | 31.2 | 25.9 | 38.0 | 34.5 | 29.3 | 28.5 | 245 K.W. 3.28 | 3.30 | 3.28 | 3.31 | 3.36 | 2.98 | 3.24 | 3.20 | 3.24 | 3.26 | 2.69 | 3.17 | 3.13 | 3.18 | 3.15 T.C. 37.6 | 39.7 | 36.5 | 41.1 | 46.0 | 36.5 | 37.4 | 35.9 | 40.2 | 45.1 | 35.4 | 35.1 | 35.4 | 39.3 | 44.1 95/75 S.C. 37.6 | 33.9 | 31.3 | 32.0 | 25.5 | 36.5 | 33.3 | 29.4 | 28.9 | 24.1 | 35.4 | 32.7 | 27.6 | 25.8 | 22.8 K.W. 3.59 | 3.60 | 3.59 | 3.60 | 3.67 | 3.29 | 3.54 | 3.51 | 3.54 | 3.57 | 3.00 | 3.48 | 3.44 | 348 | 3.47 T.C. 33.3 | 348 | 31.8 | 36.1 | 40.6 | 32.5 | 33.0 | 31.5 | 35.5 | 40.0 | 31.7 | 31.2 | 31.2 | 34.9 | 39.4 105 / 83 S.C. 33.3 | 31.0 | 28.4 | 29.5 | 23.3 | 32.5 | 30.3 | 26.9 | 27.0 | 22.1 | 31.7 | 29.6 | 25.4 | 24.5 | 20.9 K.W. 4.01 | 4.03 | 4.01 | 4.03 | 4.09 | 3.72 | 3.97 | 3.94 | 3.97 | 3.99 | 3.44 | 3.90 | 3.86 | 3.90 | 3.90 T.C. 29.2 | 30.1 | 27.3 | 31.1 | 35.3 | 28.7 | 28.8 | 27.2 | 30.9 | 35.0 | 28.2 | 27.4 | 27.1 | 30.7 | 34.7 115/89 S.C. 29.2 | 28.2 | 25.6 | 27.2 | 21.2 | 28.7 | 27.4 | 24.4 | 25.2 | 20.1 | 28.2 | 26.7 | 23.3 | 23.1 | 19.0 K.W. 4.43 | 4.45 | 4.42 | 4.45 | 4.50 | 4.14 | 4.38 | 4.35 | 4.37 | 4.41 | 3.86 | 4.31 | 4.28 | 4.30 | 4.31 T.C. 25.1 | 25.4 | 22.8 | 26.2 | 30.1 | 24.9 | 24.5 | 22.9 | 26.4 | 30.1 | 24.7 | 23.7 | 23.0 | 26.5 | 30.1 125/95 S.C. 25.1 | 25.4 | 22.8 | 24.8 | 19.1 | 24.9 | 24.5 | 22.0 | 23.3 | 18.1 | 24.7 | 23.7 | 21.2 | 21.8 | 17.2 K.W. 4.84 | 4.86 | 4.83 | 4.87 | 4.91 | 4.57 | 4.79 | 4.76 | 4.78 | 4.82 | 4.29 | 4.71 | 4.69 | 4.70 | 4.73 Johnson Controls Unitary Products 7 5006143-YTG-F-1017 COOLING PERFORMANCE DATA - 4 TON PACKAGED UNIT MODEL NO. | PCG4B48 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 58.1 | 61.5 | 60.2 | 66.8 70.0 | 55.6 | 595 | 58.7 | 65.1 | 70.0 | 53.1 | 57.5 | 57.2 | 63.4 | 69.9 55 / 45 S.C. 57.1 | 53.6 | 44.4 | 44.1 | 33.9 | 54.5 | 499 | 42.1 | 41.9 | 335 | 51.9 | 46.3 | 397 | 39.6 | 33.0 K.W. 2.21 | 2.21 | 220 | 2.23 | 2.25 | 220 | 2.21 | 220 | 2.23 | 224 | 218 | 220 | 219 | 222 | 2.23 T.C. 544 | 56.8 | 55.7 | 622 | 66.3 | 52.1 | 55.1 | 54.4 | 60.9 | 65.7 | 498 | 53.4 | 53.1 | 595 | 65.1 65/55 S.C. 54.0 | 51.5 | 42.4 | 42.4 | 324 | 51.6 | 48.0 | 40.1 | 40.2 | 31.5 | 492 | 445 | 379 | 38.0 | 306 K.W. 2.46 | 2.47 | 2.46 | 2.49 | 2.50 | 2.44 | 2.46 | 2.45 | 2.49 | 2.49 | 2.43 | 2.46 | 2.45 | 2.48 | 2.49 T.C. 50.8 | 52.2 | 51.2 | 57.6 | 62.5 | 48.7 | 50.7 | 50.1 | 56.6 | 61.4 | 46.5 | 49.3 | 49.0 | 55.6 | 60.3 75/63 S.C. 50.8 | 49.5 | 40.4 | 40.6 | 30.9 | 48.7 | 46.0 | 38.2 | 38.5 | 295 | 46.5 | 426 | 36.0 | 36.3 | 28.2 K.W. 2.71 | 2.73 | 2.72 | 2.75 | 2.76 | 2.69 | 2.72 | 2.71 | 2.75 | 2.75 | 2.68 | 271 | 270 | 2.74 | 2.74 T.C. 46.5 | 47.2 | 46.2 | 52.4 | 57.6 | 44.6 | 46.0 | 45.1 | 51.5 | 56.8 | 42.8 | 44.9 | 44.1 | 50.6 | 56.0 85/69 S.C. 46.5 | 45.8 | 37.7 | 38.1 | 28.7 | 44.6 | 42.9 | 35.5 | 35.9 | 275 | 42.8 | 40.0 | 33.3 | 33.8 | 26.3 K.W. 3.05 | 3.06 | 3.05 | 3.08 | 3.09 | 3.04 | 3.05 | 3.04 | 3.08 | 3.09 | 3.02 | 3.05 | 3.03 | 3.07 | 3.08 TC. 42.2 | 42.2 | 41.2 | 47.2 | 52.7 | 40.6 | 41.3 | 40.2 | 46.4 | 52.2 | 39.0 | 40.5 | 39.2 | 45.5 | 51.7 95/75 S.C. 42.2 | 42.2 | 35.0 | 35.6 | 26.5 | 40.6 | 39.8 | 32.9 | 33.4 | 25.4 | 39.0 | 37.4 | 30.7 | 31.2 | 24.3 K.W. 3.39 | 3.38 | 3.38 | 3.41 | 3.42 | 3.38 | 3.38 | 3.38 | 3.41 | 3.42 | 3.36 | 3.38 | 3.37 | 3.40 | 3.42 T.C. 37.2 | 37.0 | 35.3 | 40.9 | 46.8 | 36.1 | 36.2 | 35.0 | 40.6 | 46.5 | 34.9 | 35.4 | 34.8 | 40.3 | 46.2 105/83 S.C. 37.2 | 37.0 | 31.2 | 33.3 | 24.7 | 36.1 | 35.2 | 30.1 | 31.3 | 23.7 | 34.9 | 33.4 | 28.9 | 29.4 | 22.7 K.W. 3.85 | 3.85 | 3.85 | 3.88 | 3.89 | 3.85 | 3.85 | 3.85 | 3.88 | 3.89 | 3.84 | 3.86 | 3.84 | 3.87 | 3.88 T.C. 32.4 | 31.9 | 29.6 | 34.9 | 41.1 | 31.7 | 31.2 | 30.1 | 35.1 | 41.0 | 30.9 | 30.5 | 30.6 | 35.3 | 41.0 115 / 89 S.C. 32.4 | 31.9 | 27.5 | 31.0 | 23.0 | 31.7 | 30.7 | 27.3 | 29.3 | 22.0 | 30.9 | 29.5 | 27.1 | 27.6 | 21.0 K.W. 4.31 | 4.31 | 4.30 | 4.33 | 4.35 | 4.30 | 4.31 | 4.30 | 4.33 | 4.34 | 4.30 | 4.31 | 4.30 | 4.33 | 4.34 T.C. 27.6 | 26.9 | 23.9 | 28.8 | 35.5 | 27.3 | 26.2 | 25.1 | 29.6 | 35.6 | 27.0 | 25.5 | 26.4 | 30.3 | 35.7 125 / 95 S.C. 27.6 269 | 239 | 28.8 | 21.2 | 27.3 | 26.2 | 24.6 | 27.4 | 20.3 | 27.0 | 25.5 | 25.4 | 25.9 | 194 K.W. 4.76 | 4.76 | 4.76 | 4.79 | 4.80 | 4.76 | 4.77 | 4.76 | 4.79 | 4.80 | 4.76 | 4.77 | 4.76 | 4.79 | 4.79 COOLING PERFORMANCE DATA - 5 TON PACKAGED UNIT MODEL NO. | PCG4B60 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 63.1 | 65.4 | 65.2 | 68.7 | 72.9 | 60.4 | 64.1 | 64.4 | 68.0 | 71.8 | 57.6 | 62.7 | 63.6 | 67.2 | 70.6 55/45 S.C. 63.1 | 58.0 | 49.1 | 46.2 | 34.9 | 60.4 | 54.7 | 46.3 | 44.2 | 339 | 57.6 | 51.4 | 434 | 422 | 328 K.W. 3.44 | 3.44 | 343 | 3.43 | 3.41 | 3.28 | 3.29 | 3.33 | 3.34 | 3.32 | 3.12 | 3.14 | 3.23 | 3.24 | 3.23 T.C. 59.1 | 61.9 | 28.9 | 32.9 | 36.7 | 56.7 | 605 | 28.4 | 32.2 | 36.0 | 54.3 | 59.1 | 27.9 | 31.6 | 35.4 65/55 S.C. 59.1 | 57.3 | 23.1 | 23.1 | 17.6 | 56.7 | 535 | 21.5 | 21.6 | 16.8 | 54.3 | 49.7 | 20.0 | 20.0 | 16.0 K.W. 3.74 | 375 | 374 | 3.76 | 3.76 | 3.57 | 3.59 | 3.61 | 3.63 | 3.64 | 3.41 | 3.43 | 3.48 | 3.50 | 3.52 T.C. 55.1 | 58.3 | 57.7 | 65.7 | 73.2 | 53.0 | 56.9 | 56.7 | 64.4 | 72.0 | 51.0 | 55.5 | 55.7 | 63.1 | 70.7 75163 S.C. 55.1 | 56.5 | 46.1 | 46.2 | 35.2 | 53.0 | 52.3 | 43.0 | 43.1 | 33.6 | 51.0 | 48.1 | 40.0 | 40.0 32.0 K.W. 4.03 | 4.05 | 4.05 | 4.09 | 4.11 | 3.87 | 3.88 | 3.89 | 3.92 | 3.96 | 3.70 | 3.72 | 3.73 | 3.76 | 3.80 T.C. 27.6 | 535 | 52.8 | 60.0 | 60.4 | 26.5 | 52.5 | 52.2 | 59.2 | 63.2 | 255 | 51.5 | 51.6 | 58.4 | 65.9 85/69 S.C. 27.6 | 52.6 | 43.8 | 44.0 | 41.4 | 26.5 | 49.3 | 40.9 | 41.1 | 35.7 | 25.5 | 46.0 | 38.0 38.1 | 30.1 K.W. 4.42 | 4.44 | 4.45 | 4.48 | 4.47 | 4.26 | 4.28 | 4.29 | 4.31 | 4.33 | 4.11 | 4.12 | 4.13 | 4.15 | 4.19 T.C. 47.5 | 48.7 | 47.9 | 54.3 | 47.5 | 46.0 | 48.1 | 47.8 | 54.0 | 54.3 | 44.4 | 47.5 | 47.6 | 53.6 | 61.1 95/75 S.C. 47.5 | 48.7 | 415 | 41.8 | 47.5 | 46.0 | 46.3 | 38.8 | 39.0 | 37.9 | 44.4 | 439 | 36.1 | 36.3 | 28.2 K.W. 4.80 | 4.84 | 4.84 | 4.86 | 4.83 | 4.66 | 4.68 | 4.69 | 4.71 | 4.70 | 4.51 | 4.52 | 4.53 | 4.55 | 4.57 T.C. 43.0 | 44.0 | 39.9 | 46.0 | 44.7 | 415 | 42.6 | 40.0 | 46.1 | 495 | 40.0 | 41.1 | 40.1 | 46.2 | 54.3 105 / 83 S.C. 43.0 | 44.0 | 35.7 | 378 | 39.3 | 415 | 41.4 | 34.1 | 35.6 | 325 | 40.0 | 38.7 | 325 | 33.3 | 25.7 KW. 5.37 | 5.40 | 541 | 5.42 | 5.41 | 5.23 | 5.25 | 5.26 | 5.26 | 5.27 | 5.10 | 5.09 | 5.11 | 5.11 | 5.13 T.C. 38.6 | 396 | 32.1 | 38.0 | 42.0 | 37.1 | 37.2 | 32.5 | 38.5 | 448 | 356 | 34.9 | 32.9 | 39.0 | 47.6 115/89 S.C. 38.6 | 39.6 | 30.0 | 33.9 | 31.3 | 37.1 | 36.6 | 295 | 32.2 | 27.4 | 35.6 | 33.7 | 29.1 | 30.5 | 23.4 KW. 5.92 | 5.96 | 5.97 | 5.96 | 5.98 | 5.79 | 5.80 | 5.82 | 5.81 | 5.83 | 5.66 | 5.64 | 5.67 | 5.66 | 5.67 T.C. 34.2 | 35.1 | 24.4 | 30.0 | 39.3 | 32.7 | 31.9 | 25.0 | 31.0 | 40.1 | 312 | 28.7 | 25.6 | 31.9 | 410 125/95 S.C. 34.2 | 35.1 | 24.4 | 30.0 | 23.4 | 32.7 | 31.9 | 25.0 | 28.8 | 222 | 31.2 | 28.7 | 25.6 | 27.6 | 21.0 K.W. 6.47 | 6.51 | 6.53 | 6.49 | 6.55 | 6.35 | 6.35 | 6.38 | 6.35 | 6.38 | 6.23 | 6.19 | 6.24 | 6.21 | 6.21 8 Johnson Controls Unitary Products 5006143-YTG-F-1017 CORNER POST + FLUE EXHAUST HOOD | INDOOR COIL Ss Ha A 4, NENE dp 22 | СОМ СОАКО EN Ei a PS ее DD rt arr ои ES RS SR a DO a, ee a Sa "LA LT ¿E Pe ot pm ада) че A pt III | (=z HIGH VOLTAGE | (SiS EZ я E Ох . м дне фан оное у до ro Paes) | OPENING 7/8 SISIIN = NÉS Zoo |, . INSI) 2222 +| © au NNN || 222277 HIGH VOLTAGE | 222727 | COMBUSTION AIR INTAKE OPENING 1-3/32" u == | нь ы E o | | HEAT EXCHANGER ACCESS PANEL COMPRESSOR ACCESS PANEL CONDENSATE DRAÍN 5 ower B | ACCESS CONTROL / HEAT LOW VOLTAGE OPENING 7/8 PANEL ACCESS PANEL GAS SUPPLY HOLE 1-5/8” WITH GROMMET OPENING OF 7/8" A0296-003 UNIT DIMENSIONS Model Dimensions A B С PCG4A36 51-1/4 35-3/4 47 PCG4A42 51-1/4 35-3/4 49 PCG4B48 51-1/4 45-3/4 53 PCG4B60 51-1/4 45-3/4 55 UNIT CLEARANCES? Direction Distance (in.) Direction Distance (in.) Top? 36 Power Entry (Right Side) 36 Side Opposite Ducts 36 Left Side 24 Duct Panel 0 Bottom? 1 1. A 1" clearance must be provided between any combustible material and the supply air duct work. 2. The products of combustion must not be allowed to accumulate within a confined space and recirculate. 3. Units must be installed outdoors. Over hanging structure or shrubs should not obstruct condenser air discharge outlet. 4. Units may be installed on combustible floors made from class A, B or C roof covering materials. Johnson Controls Unitary Products 9 5006143-YTG-F-1017 INDOOR BLOWER SPECIFICATIONS Motor Model HP RPM EFF. SF Frame 24050 1/3 Variable 0.8 1.0 48 24075 1/2 Variable 0.8 1.0 48 30050 1/3 Variable 0.8 1.0 48 30075 1/2 Variable 0.8 1.0 48 36050 1/2 Variable 0.8 1.0 48 36075 1/2 Variable 0.8 1.0 48 36100 3/4 Variable 0.8 1.0 48 42075 3/4 Variable 08 1.0 48 42100 3/4 Variable 0.8 1.0 48 48065 3/4 Variable 0.8 1.0 48 48100 3/4 Variable 0.8 1.0 48 48125 3/4 Variable 0.8 1.0 48 60065 1 Variable 0.8 1.0 48 60100 1 Variable 0.8 1.0 48 60125 1 Variable 0.8 1.0 48 SOUND PERFORMANCE Model Sound Rating! Octave Band Centerline Frequency (Hz) (Tons) dB (A) 125 250 500 1000 2000 4000 8000 PCG4A36 74 58.5 61.8 65.4 66.5 60.7 54.8 49.8 PCG4A42 74 63.5 63.9 62.3 65.0 64.0 54.1 46.6 PCG4B48 74 63.5 63.9 62.3 65.0 64.0 54.1 46.6 PCG4B60 76 - 72.3 65.0 63.9 64.0 60.0 55.5 49.0 1. Rated in accordance with AHRI Standard 270. ELECTRICAL DATA Compressor OD Fan Supply MCA” Max Fuse?/ Model Voltage Motor Blower Motor Breaker? Size RLA | LRA | MCC FLA FLA (Amps) (Amps) 36050, 36075 208/230-3-60 8.3 68.0 14.5 1.3 3.8 15.5 20 36100 208/230-3-60 8.3 68.0 14.5 1.3 5.4 17.1 25 42075, 42100 208/230-3-60 13.5 88.0 21.1 1.3 5.4 23.6 35 48065, 48100, 48125 208/230-3-60 13.7 83.1 214 1.7 5.4 24.2 35 60065, 60100, 60125 208/230-3-60 16.0 110.0 24.9 1.7 7.0 28.7 40 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. 10 Johnson Controls Unitary Products 5006143-YTG-F-1017 CENTER OF GRAVITY WEIGHTS AND DIMENSIONS Model Weight (Ibs.) Center of Gravity 4 Point Load Location (Ibs.) Shipping Operating X Y A 5 с D 36050 425 420 28 15 141 107 94 78 36075 432 427 28 15 135 115 103 74 36100 436 431 28 15 139 113 99 80 42075 446 441 28 15 145 112 99 85 42100 448 443 28 15 148 110 96 89 48065 520 515 28 15 189 116 93 117 48100 528 523 28 15 169 139 115 100 48125 533 528 28 15 164 145 124 95 60065 537 532 29 15 174 142 124 92 60100 541 536 28 15 177 140 117 102 60125 548 543 27 15 151 167 141 84 Johnson Controls Unitary Products 11 5006143-YTG-F-1017 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION External Static Pressure Model Motor Speed 0.1 0.2 0.3 0.4 0.5 SCFM SCFM SCFM SCFM SCFM Low (1) 1003 952 851 790 Low/Medium (2) 1180 1133 1042 995 Medium (3) 1259 1209 1126 1084 (4) 1271 1186 1144 High (5) 1471 1389 1345 Low (1) 1174 1090 1046 Low/Medium (2) 1209 1084 Medium (3) 1271 1144 (4) (5) 1345 Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) Medium/High (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Continued on next page. 12 Johnson Controls Unitary Products 5006143-YTG-F-1017 AIRFLOW PERFORMANCE - SIDE DUCT APPLICATION (Continued) External Static Pressure Model Motor Speed 0.1 0.2 0.3 0.4 0.5 SCFM SCFM SCFM SCFM SCFM Low (1) 2063 2008 1943 1899 1851 Low/Medium (2) 2130 2084 2032 1983 1927 Medium (3) 2195 2144 2098 2049 2003 (4) 2275 2252 2154 2112 (5) 2445 2388 2306 2293 2235 1. Airflow tested with dry coil conditions, without air filters, at 230 volts 2. Applications above 0.8” w.c. external static pressure are not recommended. 3. Brushless DC high efficiency standard ECM blower motor used for all indoor blower assembles. 4. Minimal vanations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. 5. Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION External Static Pressure Model Motor Speed 0.1 0.2 0.3 0.4 0.5 SCFM SCFM SCFM SCFM SCFM Low (1) 1008 962 916 861 807 Low/Medium 1190 1148 1106 1055 1008 Medium (3) 1262 1223 1181 1137 1091 Medium/High (4) 1324 1245 1202 1161 High (5) 1517 1447 1400 1357 Low (1) 1231 1146 1069 Low/Medium (2) 1270 1098 Medium (3) 1317 (4) 1358 (5) 1517 Low (1) 1340 Low/Medium (2) 1409 Medium (3) (4) 1663 (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Low (1) Low/Medium (2) Medium (3) (4) (5) Continued on next page. Johnson Controls Unitary Products 13 5006143-YTG-F-1017 AIRFLOW PERFORMANCE - BOTTOM DUCT APPLICATION (Continued) External Static Pressure Model Motor Speed 0.1 0.2 0.3 0.4 0.5 SCFM SCFM SCFM SCFM SCFM Low (1) 1598 1548 1502 1454 1410 Low/Medium (2) 1766 1703 1656 1611 1566 Medium (3) 1912 1875 1787 1750 (4) 2105 2014 1931 1898 (5) 2131 2058 1949 1892 Low (1) 1026 999 950 907 Low/Medium (2) 1263 1165 1167 Medium (3) 1987 1820 (4) 2114 1899 (5) 2369 Low (1) 1655 Low/Medium (2) 1766 Medium 1987 Medium/High (4 2114 2050 (5) 2369 2308 Low (1) 1973 1924 Low/Medium (2) 2024 1983 Medium (3) 2123 2075 Medium/High (4) 2191 2154 2117 (5) 2369 2308 2249 Airflow tested with dry coil conditions, without air filters, at 230 volts Applications above 0.8" w.c. external static pressure are not recommended. . Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies . Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. . Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c esp per standards. WON — 14 Johnson Controls Unitary Products ADDITIONAL STATIC RESISTANCE Wet Indoor 0.01 0.00 0. 0.01 0.03 0.01 0.04 0.01 0.05 01 0.07 0.03 0. 0.04 0. 0.02 A42 (3.5) 09 1 1 1. The pressure drop through the economizer is greater for 100% outdoor au than for 100% return air. If the resistance of the return ar duct 1s less than 0.25 IWG, the unit will deliver less CFM during full economizer operation Filter pressure drop based on standard filter media tested at velocities not to exceed 300 fy/min. Johnson Controls Unitary Products 5006143-Y TG-F-1017 BOTTOM DUCT DIMENSIONS (Inches) e— 16-——) VIEW LOOKING UP jo AT BOTTOM OF UNIT_* 7573, c | T1 | RETURN ” | AIR DUCT | e HOLE 163 E B (with 0 88° grommet | opening for gas pipe.) | HOLE 1.09" A SUPPLY (for high AIR DUCT voltage.) | HOLE 0 88" (for low a F A RUN Model A B С D Е F 36, 42 10 215 5 45 | 475 32 48, 60 14 135 5 35 | 475 42 REAR DUCT DIMENSIONS (Inches) | 5 NOTE: See Figure titled “Unit Dimensions” for side hole sizes of electrical and gas lines Model A В 36, 42 96 22 48. 60 13.6 14 15 5006143-YTG-F-1017 UNIT TYPICAL DUCT APPLICATIONS ROOF CURB INSTALLATION ROOF CURB REAR DUCT INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION AT, UNIT TYPICAL SLAB ON GROUND INSTALLATION TO POWER SUPPLY RETURN dé" AIR DUCT H SUPPLY | AIR DUCT > ‘ IT] : FIELD-SUPPLIED A 8 | | DISCONNECT A ча й | SWITCH CONDENSATE DRAIN MANUAL GAS | | ‘ SHUTOFF VAVLE sx L— CONTROL WIRING TO INDOOR THERMOSTAT SUPPLY LINE des eu 16 Johnson Controis Unitary Products 5006143-YTG-F-1017 ROOF ROOF CURB FIELD-SUPPLIED DISCONNECT SWITCH ACE OO SUPPLY AIR DUCT | | tly 17 UNIT TYPICAL ROOF CURB INSTALLATION ы y Aa MANR NANA \ MUZE GT НЕ défis té tsar sata ti ritié MERIDA \ (IE RAI RE ; | MUNI TO GAS SUPPLY LINE SHUTOFF VAVLE TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT DRAIN MANUAL GAS RETURN AIR DUC Johnson Controls Unitary Products NOTES Subject to change without notice. Published in U.S A 5006143-YTG-F-1017 Copyright © 2017 by Johnson Controls, Inc. All rights reserved Supersedes: 5006143-YTG-E-0717 York International Corp. 5005 York Drive Norman, OK 73069 1 2% uni CD {§ United Technologies SUBMITTAL Project 10262017 S Coast Hwy Date Thursday, October 26, 2017 Table Of Contents : 10/26/2017 Project: 10262017 S Coast Hwy Prepared By: 08:24AM PGE-2TON DE 3 Unit Report... eee een RE eee eee ana 4 Certified Draw Greene ET |. 5 Performance Summary... EEE es 6 Page 2 of 8 Packaged Rooftop Builder 1.49a Project: 10262017 S Coast Hwy Prepared By: PGE - 2 TON 10/26/2017 08:24AM PGE - 2 TON Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.49a Page Зо! 8 Unit Report For PGE -2 TON Project: 10262017 S Coast Hwy 10/26/2017 Prepared By: 08:24AM Unit Parameters Dimensions (ft. in.) & Weight (Ib.) *** Unit Model:.......... ABVLNC240403-TP Unit Length: ' 0.1875" Unit SIZe: aan aan 24 (2.0 Tons) Unit Width: 2 8.625" Volts-Phase-Hertz:........... En 208-1-60 Unit Height:............. 3 7.75" Heating Type: oo, Gas *** Weights and Dimensions are approximate. Weight does not include roof , - ; curbs, unit packaging, field installed accessories or factory Duct Cfa UU Vertical Supply Vertical Return instalied options. Approximate dimensions are provided primarily for 40,000 Btuh shipping purposes. For exact dimensions and weights, refer to appropriate Low NOx Unit product data catalog. Total Operating Weight: . o... 304 Ib Unit Configuration Tin-Plated Indoor Coil Hairpins Warranty Information 1 year warranty on parts 5 year warranty on compressor 5 year warranty on heat exchanger No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48VILNC240403-TP Rooftop Unit 2 Base Unit Tin-Plated Indoor Coil Hatrpins Packaged Rooftop Builder 1.49a Page 4 of 8 Certified Drawing for PGE - 2 TON Project: 10262017 S Coast Hwy Prepared By: 10/26/2017 08:24AM ELECTRICAL CHARACTERS TSTICS 1-62 — Q-1t5/16 [257.4] pa — AIT YZL TAGE 2-471 16%. 9) NETO: SUFPLT CATIONAL м P RETUAR | ! ap ETRE | AIR [432.83 (+52 = A \ DIO COM \-ситовой сель TOP VIEW =x [1:33 8] 2-53 СН, SELECTION LAS PAKEL / # 1-406" [26.8] ЭТА, К. PEMES ENT! 43-178 278" [22.21 [14 (23.07 CORTREL 15-15774 i 41 MILE CD Y — 17 2. RAT "716 dis ESTA de-1:16 [47.4] EALTA QU {3224.01 1-137:6 GES RARE [4.6] Chis а) LEFT SDE VIEW FRONT VIEW RIGHT SIDE VIEW REQUIRED CLEARMNCES ТО CONBUSIELE MAIL [CHES (4H) TCP OF FETO 14 [353.6] BUT SIDE DE GMIT.... 2... eee 2 [50.8] SIME PIGSITE UCTS. arre aan aa ta [355.6] YCTTOM CF UNIT. .... ee. eeeeaene venere. POT vig КРТ FLSE PANEL... ........ 29. 2erraear ea a es a a se ea a eee 16 [474.4] МЕС. REDURED CLEARANCEX INCHES [mp] SETREEX YRITS, COVER ENTRY SIDE... e. e... о CET dè Crtée x] If a AND URCROUNDED SURFACES, PONER EXTAY 10DE...........56 [46,8] UNIT $ ÉLÔCE (x EMO SETE WALLS Axx OTHER Date SUNFaCES, PosEr ExTut SPEE Evar. coil к ies SINE. naaa, As ENTES SISE 2... ne. ae ana. LEE Po Ну RE TAEMENTS eNIXIMON CLSTANCES: IF UNIT 15 PLACES LESS THAK ..43 [11468] INCHES „EM RE na AT ae e и , AR CA. 2] ee 19M.) en 12 {304 3) © [196,8] FROH WALL SYSTEW, THEx 2YSTEM FEAF Gc HAT9E COMPROMITEZ, JIRERSTCRE Iw [1 akE In Jet 313 [166.7] a [¢ 8] RETU™ SFTUENC : 1-73 21-518 5-7/8 1230.6] EST. 3 [750.81] REAR VIEW ¿BL 509434 | _ | Packaged Rooftop Builder 1.49a Page 5 of 8 Performance Summary For PGE - 2 TON Project: 10262017 S Coast Hwy 10/26/2017 Prepared By: 08:24AM Part Number:48VLNC240403-TP ARISEER:! A A erro 14.00 Base Unit Dimensions Ut LONG eee eee eee eee анани 48.2 in Unit VIO EN ...32.6 in Unit IGE, eee A A 43.8 in Total Operating Weight:................... een aaa aa eee eee eee eee eee eee eee 304 ib Unit Unit Voltage-Phase-Hertz: _ m—— aaa ene enana eee rar 208-1-60 AT DS CN A NG O A NN Vertical Fan Drive - AD Direct AC UAL AIT OW eee eee eee eee eee ee eee eee eee eee eee 123 СЕМ SU - A A ee AD 0 ft Cooling Performance CONAENS Er ENE ING AIT DB eee eee eee eee eee eee eee eee eee eee ees eee eee sees eee 95.0 F EVP OratOr EN ering Air DB eee eee eee eee eee eee eee 80.0 F Емарога! ог Entering AI VNB eee eee eee eee eee eerste eres) 67.0 F Entering Air Er AID eee eee eee ere verrerie ere eee ere nee 31.44 BTU/b Evaporator Leaving Air DB eee eee eee eee eee eee eee eee ere ee a 591 F Evaporator Leaving Air WB: . Ñan eee eee eee eee eee eee eee eee eee) 571 F Evaporator Leaving Air Enthalpy:.............. eee inn eee eee) 24.48 BTU/lb Net Cooling Capacity: EEE EEE 22.62 MBH Nt SENSIDIE CAPACI Y oe eee eee eee eee eee eee eee eee 16.30 MBH Total Unit Power Input. aaa aaa a ae EEE 1.98 KW Coil Bypass Factor. AL a a Oooo aaa 0.022 Heating Performance [510 Nail en 723 CFM EE TING AE TOI UD oe eee eee rer eee eee rer eee 70.0 F Leaving Air Tem A NDS 112.3 F Gas Heating Input Capacity: eee reee ree en Aena Dean eLo eee rer ere ee 40.0 MBH Gas Heating Output Capacity: RS 33.0 MBH Temperature Rise: rc ccrrrereennier 823 F E UN A 81.0 Supply Fan External Static Pressure: . . nana recevra ere eee 0.50 inwg Options / Accessories Static Pressure Wet COIÏ: A 0.04 in wg Total Application Static (ESP + Unit Opts/Acc ue an 0.54 in wg Fan RPM: _ A A 1050 Fa POW A IA 0.26 BHP Fan MOOT SIZE, ND eee нато анонооано сана нас оаоу оне тененан 1/2 à [071 AN Medium Motor Speed, Vert Electrical Data Minimum Voltage. O er ee eee Eee eee a ee 197 Maximum Voltage. een RE 253 Compressor RLA: aa a ee 8.7 Согпргеззог СКА: een 46 Outdoor Fan FLA (CA)... неее eee ee eee eee eee eee sees eee eee eee 0.6 Indoor Fan Motor FLA:...…...….….. EEE nn 3.8 Power SUP DIY MC A ae ee aaa 15.2 Power Supply MOCP (Fuse OF HA C R ioe eee eee anna La aL ara inn осо несе нсснос 20 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Packaged Rooftop Builder 1.49a Page 6 of 8 Performance Summary For PGE - 2 TON Project: 10262017 S Coast Hwy | 10/26/2017 Prepared By: 08:24AM Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA ‘NA 54.3 250 Hz NA NA 61.3 500 Hz NA NA 55.2 1000 Hz NA NA 54.8 2000 Hz NA NA 57.1 4000 Hz NA NA 53.6 8000 Hz NA NA 43.1 Advanced Acoustics 1. Unit height above ground... 30.0 ft 2. Horizontal distance from unit to receiver:............... 50.0 ft 3. Receiver height above ground: . — ———... 5.7 ft 4. Height of obstruction:.. … 0.0 ft 5. Horizontal distance from obstruction to receiver:. 0.0 ft 6. Horizontal distance from unit to obstruction: … 0.0 ft Detailed Acoustics Information | \ Octave Band Center Freq. Hz | 63 |125 |250 |500 | 1К |! 2k | 4k | 8k | Overall A : 0.0 154.3/61.3|55.2|54.8|57.1|53.6|43.1 164.8 Lw B - |38.2/52.7|52.0154.8/58.3/54.6/42.0162.1 LwA 26.2 C 0.0 121.9/28.9/22.8|22.4|24.7|21.2|10.7 132.4 Lp D 5.8 120.3|19.6|22.4/25.9122.21 9.6 129.7 LpA 26.2 Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LWA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed Packaged Rooftop Builder 1.49a Page 7 of 8 5. Performance Summary For PGE - 2 TON Project: 10262017 S Coast Hwy 10/26/2017 Prepared By: 08:24AM that the user.is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.49a Page 8 of 8 ul YORK TECHNICAL GUIDE=— ¡ED | SINGLE PACKAGE | AIR CONDITIONER/GAS 08 14 SEER - R-410A 2 THRU 5 NOMINAL TONS | 50 - 125 MBH HEAT INPUT MODELS: PCG4*24 THRU 60 is LL + те Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.upgnet.com and www.york.com Additional rating information can be found at: www.ahridir or WARRANTY SUMMARY" Extended 10-Years limited parts and compressor warranty Lifetime gas heat exchanger * Extended warranty requires online registration within 90 days of purchase for replacement or closing for new home purchase. See limited warranty certificate in User's Information Manual for details 5005562-YTG-A-0215 DESCRIPTION These packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. FEATURES Operating Efficiency - All PCG4 model gas units provide a minimum AFUE of 81.0% in heating and 14.0 SEER, 11.0 EER rating for cooling operation. All models meet current California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts * On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexi- bility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibil- ity with less inventory. * Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor cur- rents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low craw! spaces without transition pieces - Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed elec- trical disconnect switch must be installed. *+ Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/ side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. » Condensate Pan - A corrosion-resistant, long-lasting, water- tight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 62- 89 standards (Ventilation for Acceptable Indoor Air Quality) + Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal * Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protec- tion. The pre-treated galvanized steel provides a better paint- to-steel bond, which resists corrosion and rust creep. Special primer formulas and finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). Continued on next page. TP 5005562-YTG-A-0215 Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an over- head crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. More Attractive Appearance - À single-piece top cover containing a top-discharge condenser fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded comers with water drip edges add to the attractive appearance. Top Discharge - The top-discharge condenser fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. Condenser Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. This design strategi- cally places embossments in the pan for optimum strength and rigidity. Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and pro- vide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. Simple Control Circuit - A low voltage gas heat printed cir- cuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-n- lock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. Protected Compressor - The compressor is internally pro- tected against high pressure and temperature. This is accomplished by the simultaneous operation of high pres- sure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durabil- ity and efficient operation. Evaporator coils will use tin-coated copper tubing with aluminum fins for effective heat transfer. Heat Exchangers - Gas heat exchangers use corrosion- resistant, stainless-steel tubular construction to provide long- life, trouble-free operation. Gas heat exchangers will be offered with lifetime warranties as standard with registration. Post Purge Induced Draft Combustion - Exhausts com- bustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable, durable and eliminates nui- sance lockouts. Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These bumers are constructed of high-grade corrosion-resistant, aluminized steel. Low Maintenance - Long life, permanently lubricated con- denser and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. The blower compartment has an additional large panel with a built-in handle tab. Removing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. Replacement Parts - The installer requires no special train- ing to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts. Johnson Controls Unitary Products 5005562-YTG-A-0215 NOMENCLATURE 1 2 3 4 5 6 7 8 9 1. Model Family 5. Gas Heating Input BTU/Hr x 1000 PCG - packaged A/C with gas heat, 050 = 50,000 BTU/Hr. input, blank = electric heat E pas som ^ vos ase rn E ci ón a 2 = 208/230-1-60, 3=208/230-3-60, 4 = 460-3-60 2. Nominal Cooling Efficiency 7. NOx Approval 4 = 14 SEER, 6 = 16 SEER, etc. X = low-NOx, blank = not low-Nox 3. Cabinet Size 8. Generation Level A = small 35 x 51, B = large 45 x 51 1 = first generation 4. Nominal Air Conditioning Cooling Capacity BTUx1000 9. Revision Level 24 = 24 000 BTU, etc A = original release, B = second release Examples: PHG4B421002X1A is a dual fuel, 14 SEER, 3-1/2 ton, large cabinet, single-stage heat, 100,000 BTU gas heat, 230 volt, single phase, low-NOx model (first generation, first release) COMPONENT LOCATION F— FAN MOTOR CONDENSER FAN COIL GUARD PANEL CONDENSER COIL (Behind Panel) CONTROL BOARD TRANSFORMER HIGH VOLTAGE CONTACTOR PRESSURE SWITCH DRAFT INDUCER BLOWER BLOWER MOTOR TXV EVAPORATOR COIL INDOOR BLOWER GAS VALVE COMPRESSOR GAS HEAT EXCHANGER REMOVABLE BASE RAILS ASSEMBLY Unit Limitations Unit Limitations Model Unit Voltage Applied Voltage Outdoor DB Temp Min | Мах Max (°F) PCG4024 208/230-1-60 187 | 252 125 PCG4030 208/230-1-60 187 | 252 125 PCG4036 208/230-1-60 187 | 252 125 PCG4042 208/230-1-60 187 | 252 125 PCG4048 208/230-1-60 187 252 125 PCG4060 208/230-1-60 187 | 252 125 Johnson Controls Unitary Products 3 5005562-Y TG-A-0215 ACCESSORIES * Rectangle to Round (Horizontal) Adapter + Propane Conversion Kit (S1-1NP0702, S1-1NP0701) - Kit (S1-1AK0109, S1-1AK0108) - Kit includes one supply and includes bumer orifices, gas valve conversion and installa- tion instructions necessary to field convert unit from natural gas to propane. Economizer for Downflow Applications (S1-2EE04708424, S1-2EE04708524) - Modulating inte- grated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. Economizer for Horizontal Applications (S1-2EE04708624, S1-2EE04708724) - Modulating inte- grated economizer provides simultaneous operation between the mechanical cooling and economizer operation. Independent blade design insures proper control and less than 1% leak rate. Includes hood and mesh bird screen filter integrated into the hood, dry bulb sensor and relief damper. Separate field accessories of single enthalpy and dual enthalpy are also available. Single/Dual Enthalpy Sensor (S1-2EC04700624) - Sensor replaces dry bulb sensor standard in economizer kit. Pro- vides improved economizer operation by sensing the dry bulb temperature from outdoors plus the enthalpy content of the outdoor air. CO2 Sensor Kit (S1-2AQ04700824) - Sensor kit detects CO2 levels automatically and overrides the economizer when CO2 levels rise above the preset limits. Outdoor Temp. Sensor Kit (S1-2EC04700724S1-2EC04700724v) - Additional outdoor air temp sensor kit used with economizers. Filter/Frame Kit (Single Phase Only) (S1-1FF0602, S1-1FF0601) - Kit contains the necessary hardware to field install return air filters into the base unit. The filter rack is suitable for either 1" or 2" filters. (filters not supplied) This kit is available for single phase horizontal or vertical duct applications. Motorized Fresh Air Damper (S1-2MD04705224, S1-2MD04705124) - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damper capable of providing 0% through 50% of outdoor air (field supplied). Closes on power loss, includes hood and screen assembly. one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current horizontal duct openings on the base unit. Transition is from rectangle to 12" round for the 1AK0108 kit and from rectangle to 14" round for the 1AK0109 kit. Rectangle to Round (Downflow) Adapter (S1-1AK0110, S1-1AK0111) - Kit includes one supply and one return air rectangle to round duct adapter. Adapters are preformed and designed to fit over current downflow duct openings on the base unit using a roof curb. Transition is from rectangle to 16" round for the 1AK0110 kit and from rectangle to 18" round for the 1AK0111 kit. Roof Curbs (S1-1RC0503, S1-1RC0501) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 8 inch high roof curbs. Roof Curbs (S1-1RC0504, S1-1RC0502) - NRCA approved curbs provide proper fit to base unit for rooftop installations. Curbs are designed to be assembled through hinge pins in each corner. Kit also provides seal strip to assure an air tight seal. These are 14 inch high roof curbs. Manual Outdoor Damper (S1-1FA0502, S1-1FA0501) - Provides 0% through 50% out- door air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes hood and screen assembly. Wall Thermostat - The units are designed to operate with standard, 24-volt electronic and electro-mechanical thermo- stats. All units can operate with single stage heat/single stage cool thermostats - with or without the economizer. Low Ambient Kit (S1-2LA04700824) - Kit provides neces- sary hardware to convert unit to operate in cooling cycle down to 0° F. Standard unit operation 45° F. Transformer Kit (S1-2EC06700124) - Kit provides neces- sary hardware to provide single phase models from factory furnished 40 VA transformer capability to 75 VA transformer capability. (Required on installations with economizer or motorized damper). Base Rail Hole Cover Kit (S1-1HC0101) - Kit provides nec- essary hardware to close off openings in base rails to block off openings, i.e. prevent animal entrance. Johnson Controls Unitary Products GUIDE SPECIFICATIONS GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. Package units give you the flexibility and choices you need in today's market. These packaged cooling/ heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation. The single-stage gas fired heaters have stainless steel tubular heat exchangers and spark to burner ignition. They are available in natural gas with field conversion to propane. DESCRIPTION Units shall be factory-assembled, single packaged, Electric Cooling/Gas Heating units, designed for outdoor installation. For SEER ratings, refer to technical literature. They shall have built in, equal size, field convertible duct connections for supply/ return or horizontal supply/return. The units shall be factory wired, piped, charged with R-410A Refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All models shall be rated in accordance with DOE and AHRI test procedures for both heating and cooling operation. Units shall be CSA listed and classified to ANSI Z21.47/CAN/ CSA 2.3 standards and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of G-90 galvanized, powder- painted steel, certified at 1000 hours salt spray test per ASTM- B117 standards. The unit top shall be a single piece design, with drip edges and no-seam corners to provide optimum water integrity. Unit shall have a rigidly mounted condenser coil guard to provide protection from objects and personnel after installation. Indoor blower section shall be insulated with foil- faced or foam insulation, fastened to prevent insulation from entering the air stream. Cabinet panels shall be separate, easily removable for servicing and maintenance. Unit shall be built on a formed, design base pan, with embossments at critical points to add strength and rigidity and to aid in minimizing sound. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, for truck access and proper sealing on roof curb applications. Base rails shall be easily removable, when required to lower unit height. Filters shall be field installed, furnished and be accessible through a removable access door, sealed airtight. Units vertical discharge and return duct configuration shall be designed to fit between standard 24" O.C. beams without modification to building structure, duct work and base unit. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining standards, with 3/4” NPT female ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY Fan shall be direct drive design. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Fan assembly shall be a slide-out design for easy removal and cleaning. Indoor blower motors shall be equipped with a standard high efficiency brushless DC motor (constant torque) also known as a standard ECM motor. Johnson Controls Unitary Products 5005562-YTG-A-0215 OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct-driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be statically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS Compressors; a. Shall be fully hermetic type, direct drive, internally pro- tected with internal high-pressure relief and over tempera- ture protection. The hermetic motor shall be suction gas cooled and have a voltage range of +/- 10% of the unit nameplate voltage. b. Shall have internal isolation and sound muffling to mini- mize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechani- cally bonded to seamless internally enhanced tin-coated copper tubes with all joints brazed. b. Evaporator coil shall be of the direct expansion, draw through design. c. Condenser coils shall have aluminum plate fins mechani- cally bonded to seamless internally enhanced copper tubes with all joints brazed. d. Condenser coil shall be draw through design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Thermal expansion devices (TXV's) shall be factory mounted and provided. b. Filter/strainer to eliminate any foreign matter. GAS HEATING SECTION (If Equipped) Heat exchanger and exhaust system shall be constructed of corrosion-resistant materials and shall be designed with induced draft combustion with post purge logic and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of stainless steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 °F. Burners shall be of the in-shot type, constructed of aluminumized steel. All gas piping shall enter the unit cabinet at a single location through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of indoor fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary high-temperature limit switch. b. Induced draft pressure switch. c. Flame roll out switch(s) (manual reset). d. Flame proving controls. All gas heat models will meet the current California requirement for emissions of less than 40 nanograms per Joule (California requirement on single phase models only). 5005562-YTG-A-0215 PHYSICAL DATA COMPONENT SO as fiters. For internal filter use, a filter rack kit is available. Consult the instructions supplied with that kit for replacement filter sizes. Filter sizes: A=20x20, B=20x30. 6 Johnson Controls Unitary Products 5005562-Y TG-A-0215 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. | PCG4A24 CONDENSER ID CFM 1000 800 600 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 30.0 | 33.4 | 33.4 | 36.7 | 398 | 274 | 30.9 | 31.2 | 34.3 | 37.6 | 24.9 | 28.4 | 290 | 31.8 | 35.4 55 / 45 S.C. 30.0 | 286 | 23.8 | 23.7 | 18.7 | 274 | 25.0 | 209 | 21.0 | 16.9 | 24.9 | 213 | 18.1 | 182 | 15.1 K.W. 148 | 147 | 147 | 146 | 1.44 | 1.44 | 1.44 | 1.44 | 1.42 | 1.40 | 1.41 | 1.41 | 1.40 | 1.39 | 1.37 T.C. 25.9 | 291 | 288 | 32.1 | 35.4 | 259 | 28.7 | 28.7 | 31.9 | 35.4 | 25.9 | 284 | 28.6 | 31.6 | 35.3 65 / 55 S.C. 25.6 | 23.6 | 19.9 | 19.9 | 16.0 | 25.7 | 23.6 | 197 | 198 | 16.0 | 25.9 | 235 | 195 | 19.7 | 16.0 K.W. 157 | 1.58 | 1.57 | 1.57 | 1.56 | 1.58 | 1.58 | 1.58 | 1.54 | 1.53 | 1.59 | 1.59 | 1.59 | 1.50 | 1.49 T.C. 26.9 | 28.4 | 282 | 31.4 | 35.3 | 24.4 | 26.6 | 26.2 | 29.4 | 33.2 | 21.9 | 24.8 | 24.2 | 27.5 | 31.1 75163 S.C. 26.9 | 25.8 | 20.9 | 21.1 | 16.8 | 24.0 | 22.2 | 18.5 | 18.6 | 15.1 | 21.2 | 18.6 | 16.0 | 16.1 | 13.3 KW. 1.77 | 1.78 | 1.78 | 162 | 1.61 | 1.72 | 1.73 | 1.73 | 1.65 | 1.65 | 1.66 | 1.68 | 1.67 | 1.69 | 1.69 T.C. 22.0 | 23.8 | 234 | 26.5 | 299 | 223 | 24.1 | 23.7 | 26.8 | 30.2 | 22.6 | 24.4 | 24.1 | 27.2 | 305 85/69 S.C. 21.7 | 206 | 17.1 | 17.4 | 13.7 | 221 | 20.9 | 17.2 | 17.5 | 13.8 | 225 | 21.1 | 17.3 | 17.5 | 139 K.W. 1.86 | 1.87 | 1.87 | 1.89 | 1.95 | 1.85 | 1.86 | 1.86 | 1.84 | 1.88 | 1.84 | 1.86 | 1.86 | 1.79 | 1.81 T.C. 22.1 | 228 | 225 | 255 | 288 | 20.2 | 21.6 | 21.3 | 24.2 | 27.3 | 18.3 | 20.3 | 20.1 | 229 | 25.8 95/75 S.C. 22.1 | 227 | 18.3 | 18.8 | 14.1 | 20.1 | 195 | 16.0 | 16.4 | 12.6 | 18.2 | 16.4 | 13.6 | 14.0 | 11.1 K.W. 2.07 | 2.07 | 2.06 | 2.09 | 2.21 | 1.98 | 2.00 | 2.00 | 2.03 | 2.11 | 1.90 | 1.94 | 1.94 | 1.97 | 2.00 T.C. 19.3 | 19.9 | 192 | 22.0 | 24.7 | 17.8 | 18.8 | 18.3 | 21.0 | 237 | 16.3 | 17.7 1 17.3 | 20.0 | 22.7 105 / 83 S.C. 19.3 | 19.8 | 16.4 | 17.2 | 11.9 | 17.8 | 17.4 | 14.4 | 14.9 | 10.8 | 16.2 | 15.1 | 12.4 | 127 | 9.8 K.W. 221 | 2.21 | 2.20 | 2.24 | 2.34 | 2.12 | 2.13 | 2.12 | 2.17 | 2.25 | 2.03 | 2.06 | 2.05 | 2.11 | 2.15 T.C. 16.6 | 170 | 16.0 | 185 | 20.7 | 15.5 | 16.1 | 15.4 | 179 | 20.2 1 14.3 151 | 14.7 | 17.3 | 19.7 115 / 89 S.C. 16.6 | 17.0 | 146 | 156 | 9.6 | 15.4 | 15.4 | 12.9 | 136 | 9.1 14.3 | 13.8 | 11.1 | 1151 86 K.W. 2.36 | 2.35 | 2.32 | 2.38 | 2.47 | 2.25 | 226 | 2.24 | 2.31 | 2.38 | 2.15 | 2.17 | 2.17 | 2.24 | 2.30 T.C. 13.9 | 14.1 | 12.8 | 15.1 | 17.6 | 13.1 | 13.4 | 124 | 14.8 | 17.2 | 12.3 | 12.6 | 12.0 | 14.5 | 16.7 125/95 S.C. 13.9 | 14.1 | 128 | 14.0 | 9.4 | 13.1 | 134 | 11.4 | 122] 84 | 12.3 | 126 | 99 | 103 | 7.4 K.W. 2.50 | 249 | 245 | 253 | 2.59 | 239 | 2.39 | 236 | 245 | 2.52 | 2.27 | 2.29 | 2.28 | 2.37 | 2.45 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. | PCG4A30 CONDENSER ID CFM 1200 1000 800 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 41.0 | 436 | 43.2 | 44.9 | 483 | 37.8 | 41.0 | 40.8 | 43.8 | 47.9 | 34.5 | 38.4 | 38.5 | 42.8 | 47.5 55 / 45 S.C. 40.2 | 38.5 | 32.6 | 31.1 | 24.5 | 36.9 | 34.5 | 29.5 | 28.8 | 23.6 | 33.6 | 30.5 | 26.4 | 26.5 | 22.6 K.W. 1.71 | 1.71 | 1.71 | 1.68 | 1.66 | 1.67 | 1.66 | 1.65 | 1.65 | 1.62 | 1.62 | 1.61 | 1.60 | 1.61 | 1.59 T.C. 374 | 40.0 | 38.8 | 41.6 | 45.6 | 34.4 | 37.6 | 36.9 | 40.5 | 44.1 | 31.4 | 35.2 | 35.1 | 39.4 | 42.6 65/55 S.C. 37.0 | 36.3 | 30.5 | 29.8 | 23.4 | 34.0 | 32.5 | 27.6 | 27.3 | 25.2 | 31.0 | 28.7 | 24.6 | 24.8 | 27.0 K.W. 1.88 | 1.89 | 1.89 | 1.88 | 1.86 | 1.83 | 1.83 | 1.83 | 1.83 | 1.82 | 1.78 | 1.77 | 1.78 | 1.78 | 1.78 T.C. 33.8 | 36.4 | 34.3 | 38.3 | 42.9 } 31.1 | 34.1 | 33.0 | 37.1 | 40.3 | 28.4 | 31.9 | 31.7 | 36.0 | 37.7 75/63 S.C. 33.8 | 34.2 | 28.4 | 28.5 | 22.3 | 31.1 | 30.5 | 25.6 | 25.8 | 26.9 | 28.4 | 26.9 | 22.8 | 23.2 | 31.5 K.W. 2.04 | 2.06 | 2.08 | 2.08 | 2.06 | 1.99 | 2.00 | 2.02 | 2.02 | 2.02 | 1.94 | 1.93 | 1.95 | 1.95 | 1.97 T.C. 30.1 | 32.3 | 29.8 | 34.2 | 38.6 | 27.8 | 30.3 | 28.8 | 33.2 | 36.6 | 25.5 | 28.2 | 27.7 | 32.1 | 34.5 85/69 S.C. 30.11 312 | 281 | 26.7 | 20.6 | 27.8 | 28.1 | 234 | 24.0 | 21.9 | 25.5 | 25.0 | 20.8 | 21.3 | 23.3 K.W. 2.22 | 2.23 | 2.24 | 2.27 | 2.27 | 2.15 | 2.16 | 2.14 | 2.19 | 2.22 | 2.09 | 2.08 | 2.03 | 2.12 | 2.16 T.C. 26.3 | 28.3 | 25.3 | 30.1 | 34.3 | 24.4 | 26.4 | 24.5 | 29.2 | 32.8 | 22.6 | 24.6 | 23.7 | 28.2 | 31.3 95/75 S.C. 26.3 | 283 | 237 | 24.8 | 18.9 | 244 | 25.7 | 21.2 | 22.2 | 17.0 | 22.6 | 23.1 | 18.7 | 19.5 | 15.1 K.W. 2.39 | 2.39 | 241 | 245 | 247 | 2.32 | 2.31 | 2.26 | 2.37 | 2.41 | 2.24 | 2.24 | 2.11 | 2.30 | 2.35 T.C. 21.4 | 248 | 20.6 | 25.9 | 28.7 | 203 | 228 1 20.0 | 24.7 | 27.8 | 19.2 | 20.8 | 19.4 | 23.4 | 26.9 105/83 S.C. 21.4 | 24.8 | 19.5 | 22.4 | 16.9 | 20.3 | 223 | 17.8 | 20.0 | 15.2 | 192 | 19.9 | 16.1 | 17.5 | 13.6 K.W. 257 | 257 | 256 | 2.61 | 2.67 | 2.49 | 249 | 2.44 | 2.50 | 2.61 | 2.41 | 2.40 | 2.32 | 2.38 | 2.55 T.C. 16.7 | 21.3 | 16.0 | 21.8 | 23.3 | 16.3 | 19.3 | 15.6 | 20.3 | 23.0 | 15.9 | 17.2 | 15.2 | 18.8 | 22.7 115/89 S.C. 16.7 | 21.3 | 15.5 | 20.1 | 14.9 | 16.3 | 19.0 | 14.5 | 17.8 | 13.5 | 15.9 1 16.7 | 13.6 | 15.6 | 12.0 K.W. 2.74 | 2.74 | 2.71 | 2.77 | 2.86 | 2.66 | 2.65 | 2.61 | 2.62 | 2.80 | 2.57 | 2.56 | 2.52 | 2.46 | 2.73 T.C. 12.0 | 17.9 | 11.4 | 17.7 | 17.8 | 12.3 | 15.7 | 11.2 | 15.9 | 18.2 | 12.6 | 13.6 | 11.0 | 14.1 | 18.5 125/95 S.C. 12.0 | 17.9 | 11.4 | 17.7 | 13.0 | 12.3 | 15.7 | 11.2 1 15.7 | 11.7 | 12.6 | 13.6 | 11.0 | 13.7 | 10.5 K.W. 2.91 | 2.91 1 2.86 | 2.92 | 3.06 | 2.83 | 2.82 | 2.79 | 2.73 | 2.99 | 2.74 | 2.72 | 2.72 | 2.55 | 2.92 Johnson Controls Unitary Products 7 5005562-YTG-A-0215 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. | PCG4A36 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 45.3 | 48.1 | 48.0 | 53.1 | 54.6 | 42.2 | 46.3 | 46.2 | 51.3 | 535 | 392 | 446 | 445 | 495 | 524 55 / 45 S.C. 45.3 | 43.2 | 36.0 | 36.5 | 27.9 | 42.2 | 39.5 | 33.3 | 33.4 | 26.1 | 392 | 35.8 | 30.6 | 304 | 244 KW. 2.15 | 2.16 | 2.16 | 2.15 | 2.15 | 2.07 | 2.07 | 2.07 | 2.06 | 2.05 | 1.99 | 199 | 1.99 | 1.97 | 1.95 T.C. 42.0 | 43.7 | 43.8 | 48.6 | 52.4 | 39.4 | 42.5 | 42.4 | 47.1 | 51.0 | 36.8 | 41.2 | 41.0 | 45.6 | 495 65 / 55 S.C. 42.0 | 40.3 | 34.1 | 345 | 26.6 | 39.4 | 36.9 | 31.3 | 31.5 | 249 | 36.8 | 33.5 | 28.6 | 28.5 | 23.1 K.W. 2.39 | 2.41 | 2.40 | 2.41 | 2.40 | 2.30 | 2.31 | 2.31 | 2.32 | 2.31 | 2.20 | 2.22 | 2.22 | 2.22 | 2.21 T.C. 38.7 | 393 | 39.6 | 44.1 | 50.1 | 36.6 | 38.6 | 385 | 42.9 | 484 | 345 | 37.9 | 37.4 | 41.7 | 46.7 75/63 S.C. 38.7 | 37.4 | 32.1 | 324 | 25.4 | 36.6 | 34.3 | 293 | 295 | 236 | 345 | 31.1 | 266 | 26.7 | 21.8 KW. 2.63 | 2.66 | 2.64 | 2.67 | 2.65 | 2.52 | 2.55 | 2.54 | 257 | 256 | 2.41 | 2.45 | 2.44 | 2.47 | 2.46 T.C. 35.3 | 35.4 | 35.5 | 39.4 | 45.0 | 33.6 | 34.8 | 34.8 | 38.7 | 43.8 | 31.9 | 34.2 | 34.0 | 38.0 | 42.7 85/69 S.C. 35.3 | 34.4 | 30.0 | 30.1 | 23.6 | 33.6 | 32.0 | 27.5 | 27.5 | 21.9 | 31.9 | 295 | 25.0 | 25.0 | 20.2 K.W. 2.87 | 290 | 2.88 | 2.93 | 2.93 | 2.75 | 2.79 | 2.77 | 283 | 2.83 | 2.64 | 268 | 2.67 | 2.72 | 2.73 T.C. 31.9 | 31.5 | 31.5 | 34.8 | 39.8 | 30.5 | 31.0 | 31.0 | 34.6 | 39.2 | 292 | 305 | 30.6 | 34.3 | 38.6 95/75 S.C. 31.9 | 31.5 | 28.0 | 27.8 | 21.8 | 30.5 | 29.7 | 25.7 | 25.5 | 20.2 | 292 | 27.9 | 23.4 | 23.3 | 187 KW. 3.11 | 3.14 | 3.12 | 3.20 | 3.21 | 2.99 | 3.02 | 3.00 | 3.08 | 3.10 | 2.87 | 2.91 | 289 | 2.97 | 2.99 T.C. 26.5 | 26.8 | 26.3 | 29.0 | 33.7 | 26.0 | 26.5 | 26.2 | 29.1 | 335 | 25.5 | 26.3 26.0 | 292 | 334 105/83 S.C. 26.5 | 26.8 | 24.0 | 244 | 19.3 | 260 | 25.7 | 226 | 228 | 18.0 | 25.5 | 245 | 212 | 21.3 | 16.7 K.W. 3.43 | 3.39 | 3.35 | 3.43 | 3.48 | 3.27 | 3.27 | 3.23 | 3.32 | 3.37 | 3.11 | 3.14 | 3.11 | 3.20 | 3.25 T.C. 21.4 | 22.3 | 21.3 | 234 | 27.7 | 21.6 | 22.2 | 214 | 23.8 | 28.0 | 218 | 222 | 215 | 242 | 283 115 / 89 S.C. 21.4 | 223 20.2 | 21.1 | 17.0 | 21.6 | 21.8 | 19.7 | 20.2 | 15.9 | 218 | 213 | 191 | 19.3 | 14.8 K.W. 3.74 | 3.65 | 3.57 | 3.67 | 3.75 | 3.54 | 3.50 | 3.44 | 3.54 | 3.63 | 3.34 | 3.36 | 3.32 | 3.42 | 3.50 T.C. 16.2 | 17.7 | 16.3 | 17.7 | 21.7 | 17.2 | 17.9 | 16.7 | 185 | 225 | 182 | 18.0 | 17.0 | 192 | 232 125/95 S.C. 16.2 | 17.7 | 16.3 | 17.7 | 14.6 | 17.2 | 17.9 | 16.7 | 17.6 | 13.8 | 18.2 | 18.0 | 17.0 | 17.4 | 13.0 K.W. 4.05 | 3.90 | 3.79 | 3.90 | 4.01 | 3.81 | 3.74 | 3.66 | 3.77 | 3.88 | 3.57 | 3.58 | 3.53 | 3.65 | 3.76 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. | PCG4A42 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 49.4 | 50.2 | 50.2 | 55.5 | 61.9 | 465 | 486 | 48.5 | 53.7 | 596 | 43.7 | 46.9 | 46.8 | 518 | 57.3 55/45 S.C. 47.8 | 45.0 | 38.5 | 396 | 32.6 | 455 | 42.1 | 36.2 | 37.0 | 30.7 | 43.1 | 39.2 | 33.9 | 34.4 | 287 K.W. 2.50 | 2.52 | 2.51 | 2.53 | 2.56 | 242 | 2.44 | 2.43 | 2.45 | 2.47 | 235 | 236 | 2.36 | 2.38 | 2.38 T.C. 46.6 | 47.0 | 47.0 | 52.1 | 58.0 | 44.4 | 45.6 | 456 | 50.5 | 56.1 | 422 | 441 | 44.1 | 489 | 54.1 65/55 S.C. 45.5 | 43.2 | 36.4 | 37.7 | 30.8 | 43.7 | 40.5 | 34.4 | 35.3 | 29.2 | 41.9 | 37.7 | 32.5 | 328 | 27.5 K.W. 2.73 | 2.76 | 2.74 | 2.77 | 2.80 | 2.55 | 2.68 | 2.66 | 2.70 | 2.71 | 236 | 261 | 259 | 2.62 | 2.61 T.C. 43.8 | 43.9 | 43.7 | 48.7 | 54.1 | 42.2 | 426 | 42.6 | 47.4 | 52.5 | 40.6 | 41.3 | 41.4 | 46.0 | 51.0 75/63 S.C. 43.3 | 41.4 | 34.3 | 35.9 | 29.0 | 41.9 | 38.8 | 32.7 | 33.6 | 27.6 | 40.6 | 36.3 | 31.0 | 31.3 | 26.2 K.W. 2.97 | 3.00 | 2.97 | 3.01 | 3.04 | 2.67 | 2.93 | 2.89 | 2.94 | 2.94 | 2.38 | 286 | 2.82 | 2.87 | 2.84 T.C. 40.7 | 41.8 | 40.1 | 44.9 | 50.0 | 39.3 | 40.0 | 39.3 | 43.8 | 48.8 | 38.0 | 38.2 | 38.4 | 42.7 | 47.6 85/69 S.C. 40.4 | 37.7 | 32.8 | 33.9 | 27.3 | 39.2 | 36.1 | 31.0 | 31.2 | 25.9 | 38.0 | 34.5 | 293 | 285 | 245 K.W. 3.28 | 3.30 | 3.28 | 3.31 | 3.36 | 2.98 | 3.24 | 3.20 | 3.24 | 3.26 | 2.69 | 3.17 | 3.13 | 3.18 | 3.15 T.C. 37.6 | 39.7 | 36.5 | 41.1 | 46.0 | 36.5 | 37.4 | 35.9 | 40.2 | 45.1 | 35.4 | 35.1 | 35.4 | 39.3 | 44.1 95/75 S.C. 37.6 | 33.9 | 31.3 | 32.0 | 25.5 | 36.5 | 33.3 | 294 | 28.9 | 24.1 | 35.4 | 32.7 | 27.6 | 258 | 22.8 KW. 3.59 | 3.60 | 3.59 | 3.60 | 3.67 | 3.29 | 3.54 | 3.51 | 3.54 | 3.57 | 3.00 | 3.48 | 3.44 | 3.48 | 3.47 T.C. 33.3 | 34.8 | 31.8 | 36.1 | 40.6 | 325 | 33.0 | 315 | 35.5 | 40.0 | 31.7 | 31.2 | 31.2 | 34.9 | 39.4 105 / 83 S.C. 33.3 | 31.0 | 28.4 | 29.5 | 23.3 | 32.5 | 30.3 | 26.9 | 27.0 | 22.1 | 31.7 | 29.6 | 254 | 245 | 20.9 K.W. 4.01 | 4.03 | 4.01 | 4.03 | 4.09 | 3.72 | 3.97 | 3.94 | 3.97 | 3.99 | 3.44 | 3.20 | 3.86 | 3.90 | 3.90 T.C. 29.2 | 30.1 | 27.3 | 31.1 | 35.3 | 28.7 | 28.8 | 27.2 | 30.9 | 35.0 | 28.2 | 27.4 | 27.1 | 30.7 | 34.7 115/89 S.C. 29.2 | 28.2 | 25.6 | 27.2 | 21.2 | 28.7 | 27.4 | 24.4 | 25.2 | 20.1 | 28.2 | 26.7 | 233 | 23.1 | 19.0 K.W. 443 | 4.45 | 4.42 | 4.45 | 4.50 | 4.14 | 4.38 | 4.35 | 4.37 | 441 | 3.86 | 4.31 | 4.28 | 4.30 | 4.31 T.C. 25.1 | 25.4 | 22.8 | 26.2 | 30.1 | 24.9 | 24.5 | 22.9 | 26.4 | 30.1 | 24.7 | 23.7 | 23.0 | 26.5 | 30.1 125/95 S.C. 25.1 | 254 | 22.8 | 248 | 19.1 | 24.9 | 245 | 22.0 | 23.3 | 18.1 | 24.7 | 23.7 | 21.2 | 21.8 | 17.2 K.W. 4.84 | 4.86 | 4.83 | 4.87 | 4.91 | 4.57 | 4.79 | 4.76 | 4.78 | 4.82 | 4.29 | 4.71 | 4.69 | 4.70 | 4.73 8 Johnson Controls Unitary Products 5005562-Y TG-A-0215 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. | PCG4B48 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 58.1 | 61.5 | 60.2 | 66.8 | 70.0 | 556 | 595 | 58.7 | 65.1 | 70.0 | 53.1 | 57.5 | 57.2 | 63.4 | 69.9 55/45 S.C. 57.1 | 536 | 444 | 441 | 33.9 | 545 | 49.9 421 | 41.9 | 33.5 | 51.9 | 46.3 | 397 | 39.6 | 33.0 K.W. 2.21 | 221 | 220 | 223 | 2.25 | 2.20 | 2.21 | 220 | 2.23 | 2.24 | 2.18 | 220 | 219 | 2.22 | 2.23 TC. 54.4 | 568 | 55.7 | 622 | 66.3 | 52.1 | 55.1 | 54.4 | 60.9 | 65.7 | 49.8 | 53.4 | 53.1 | 595 | 65.1 65/55 S.C. 54.0 | 515 | 424 | 424 | 324 | 516 | 48.0 | 40.1 | 40.2 | 31.5 492 | 44.5 | 37.9 | 38.0 | 30.6 K.W. 246 | 247 | 246 | 249 | 250 | 2.44 | 2.46 | 245 | 2.49 | 249 2.43 | 2.46 | 2.45 | 2.48 | 2.49 T.C. 50.8 | 522| 512| 576 | 625 | 48.7 | 50.7 | 50.1 | 56.6 | 61.4 | 46.5 | 49.3 | 49.0 | 55.6 | 60.3 75/63 S.C. 50.8 | 495 | 40.4 | 40.6 | 30.9 | 48.7 | 46.0 | 38.2 | 38.5 | 29.5 | 46.5 | 42.6 | 36.0 | 36.3 | 28.2 K.W. 2.71 | 2.73 | 2.72 | 2.75 | 2.76 | 269 | 2.72 | 271 | 2.75 | 2.75 | 2.68 | 2.71 | 2.70 | 2.74 | 2.74 T.C. 46.5 | 47.2 | 46.2 | 52.4 | 57.6 | 44.6 | 46.0 | 45.1 | 51.5 | 56.8 | 42.8 | 44.9 | 44.1 | 50.6 | 56.0 85 / 69 S.C. 46.5 | 45.8 | 37.7 | 38.1 | 287 | 446 | 42.9 | 35.5 | 35.9 | 27.5 | 42.8 | 40.0 | 33.3 | 33.8 | 26.3 K.W. 3.05 | 3.06 | 3.05 | 3.08 | 3.09 | 3.04 | 3.05 | 3.04 | 3.08 | 3.09 | 3.02 | 3.05 | 3.03 | 3.07 | 3.08 TC. 42.2 | 42.2 | 412 | 47.2 | 52.7 | 40.6 | 41.3 | 40.2 | 46.4 | 52.2 | 39.0 | 40.5 | 39.2 | 45.5 | 51.7 95/75 S.C. 422 | 422 | 35.0 | 35.6 | 26.5 | 40.6 | 39.8 | 32.9 | 33.4 | 25.4 | 39.0 | 37.4 | 30.7 | 31.2 | 24.3 K.W. 3.39 | 3.38 | 3.38 | 3.41 | 3.42 | 3.38 | 3.38 | 3.38 | 3.41 | 3.42 | 336 | 3.38 | 3.37 | 3.40 | 3.42 T.C. 37.2 | 37.0 | 353 | 409 | 46.8 | 36.1 | 36.2 | 35.0 | 40.6 | 46.5 | 34.9 | 35.4 | 34.8 | 40.3 | 46.2 105/83 S.C. 37.2 | 37.0 | 31.2 | 33.3 | 24.7 | 36.1 | 35.2 | 30.1 | 31.3 | 23.7 | 34.9 | 334 | 28.9 | 29.4 | 22.7 K.W. 3.85 | 3.85 | 3.85 | 3.88 | 3.89 | 3.85 | 3.85 | 3.85 | 3.88 | 3.89 | 3.84 | 386 | 3.84 | 3.87 | 3.88 T.C. 32.4 | 31.9 | 29.6 | 34.9 | 41.1 | 31.7 | 31.2 | 30.1 | 35.1 | 41.0 | 30.9 | 30.5 | 30.6 | 35.3 | 41.0 115/89 S.C. 32.4 | 31.9 | 27.5 | 31.0 | 23.0 | 31.7 | 30.7 | 27.3 | 29.3 | 22.0 | 30.9 | 295 | 27.1 | 27.6 | 21.0 K.W. 4.31 | 4.31 | 4.30 | 4.33 | 4.35 | 4.30 | 4.31 | 4.30 | 4.33 | 4.34 | 4.30 | 4.31 | 4.30 | 4.33 | 4.34 T.C. 27.6 | 26.9 | 23.9 | 28.8 | 35.5 | 27.3 | 26.2 | 25.1 | 29.6 | 35.6 | 27.0 | 25.5 | 26.4 | 30.3 | 35.7 125/95 S.C. 27.6 | 26.9 | 23.9 | 28.8 | 21.2 | 27.3 | 26.2 | 24.6 | 27.4 | 20.3 | 27.0 | 25.5 | 25.4 | 25.9 | 19.4 K.W. 4.76 | 4.76 | 4.76 | 4.79 | 4.80 | 4.76 | 4.77 | A.76 | 4.79 | 4.80 | 4.76 | 4.77 | 4.76 | 4.79 | 4.79 COOLING PERFORMANCE DATA PACKAGED UNIT MODEL NO. | PCG4B60 CONDENSER ID CFM 1600 1400 1200 ENTERING AIR IDDB 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE IDWB 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72 T.C. 63.1 | 65.4 | 65.2 | 68.7 | 729 | 60.4 | 64.1 | 64.4 | 68.0 | 71.8 | 57.6 | 62.7 | 63.6 | 67.2 | 70.6 55/45 S.C. 63.1 | 58.0 | 49.1 | 46.2 | 34.9 | 60.4 | 54.7 | 46.3 | 44.2 | 33.9 | 57.6 | 51.4 | 43.4 | 42.2 | 32.8 K.W. 344 | 3.44 | 3.43 | 3.43 | 3.41 | 3.28 | 3.29 | 3.33 | 3.34 | 3.32 | 3.12 | 3.14 | 3.23 | 3.24 | 3.23 T.C. 59.1 | 619 | 28.9 | 32.9 | 36.7 | 56.7 | 60.5 | 28.4 | 32.2 | 36.0 | 54.3 | 59.1 | 27.9 | 31.6 | 354 65/55 S.C. 59.1 | 57.3 | 23.1 | 23.1 | 17.6 | 56.7 | 535 | 21.5 | 21.6 | 16.8 | 54.3 | 497 | 20.0 | 20.0 | 16.0 K.W. 3.74 | 3.75 | 3.74 | 376 | 3.76 | 357 | 359 | 3.61 | 3.63 | 3.64 | 3.41 | 3.43 | 3.48 | 3.50 | 3.52 T.C. 55.1 | 58.3 | 57.7 | 65.7 | 73.2 | 53.0 | 56.9 | 56.7 | 64.4 | 72.0 | 51.0 | 55.5 | 55.7 | 63.1 | 70.7 75/63 S.C. 55.1 | 56.5 | 46.1 | 46.2 | 35.2 | 53.0 | 52.3 | 43.0 | 43.1 | 33.6 | 51.0 | 48.1 | 40.0 | 40.0 | 32.0 K.W. 4.03 | 4.05 | 4.05 | 4.09 | 4.11 | 3.87 | 3.88 | 3.89 | 3.92 | 3.96 | 3.70 | 3.72 | 3.73 | 3.76 | 3.80 T.C. 27.6 | 53.5 | 52.8 | 60.0 | 60.4 | 26.5 | 525 | 52.2 | 59.2 | 63.2 | 255 | 51.5 | 51.6 | 58.4 | 65.9 85/69 S.C. 27.6 | 52.6 | 438 | 44.0 | 41.4 | 26.5 | 49.3 | 40.9 | 41.1 | 35.7 | 25.5 | 46.0 | 38.0 | 38.1 | 30.1 K.W. 4.42 | 4.44 | 445 | 448 | 447 | 4.26 | 4.28 | 4.29 | 4.31 | 4.33 | 4.11 | 4.12 | 4.13 | 4.15 | 4.19 T.C. 47.5 | 48.7 | 47.9 | 543 | 475 | 46.0 | 48.1 | 47.8 | 54.0 | 54.3 | 44.4 | 475 | 47.6 | 53.6 | 61.1 95/75 S.C. 47.5 | 48.7 | 41.5 | 41.8 | 47.5 46.0 | 46.3 | 38.8 | 39.0 | 37.9 | 44.4 | 439 | 36.1 | 36.3 | 28.2 K.W. 4.80 | 4.84 | 4.84 | 4.86 | 4.83 | 4.66 | 4.68 | 4.69 | 4.71 | 4.70 | 4.51 | 4.52 | 4.53 | 4.55 | 4.57 T.C. 43.0 | 440 | 399 | 46.0 | 44.7 | 41.5 | 42.6 | 40.0 | 46.1 | 495 | 40.0 | 41.1 | 40.1 | 46.2 | 54.3 105/83 S.C. 43.0 44.0 | 35.7 | 37.8 39.3 | 415 | 414 | 34.1 | 35.6 | 32.5 | 400 | 38.7 | 325 | 33.3 | 257 KW. 5.37 | 5.40 | 541 | 542 | 541 | 5.23 | 5.25 | 5.26 | 5.26 | 5.27 | 5.10 | 5.09 | 5.11 | 5.11 | 5.13 T.C. 386 | 396 | 32.1 | 38.0 | 42.0 | 37.1 | 37.2 | 325 | 38.5 | 44.8 | 35.6 | 34.9 | 32.9 | 39.0 | 47.6 115/89 S.C. 38.6 | 396 | 30.0 | 339 | 31.3 | 37.1 | 36.6 | 295 | 322 | 27.4 | 35.6 | 33.7 | 29.1 | 30.5 | 234 K.W. 5.92 | 5.96 | 5.97 | 5.96 | 5.98 | 5.79 | 5.80 | 5.82 | 5.81 | 5.83 | 5.66 | 5.64 | 5.67 | 5.66 | 5.67 T.C. 34.2 | 35.1 | 24.4 | 30.0 | 39.3 | 32.7 | 31.9 | 25.0 | 31.0 | 40.1 | 312 | 28.7 | 25.6 | 31.9 | 41.0 125/95 S.C. 34.2 | 35.1 | 244 | 30.0 | 23.4 | 32.7 | 31.9 | 25.0 | 28.8 | 22.2 | 31.2 | 28.7 | 25.6 | 27.6 | 21.0 K.W. 6.47 | 6.51 | 6.53 | 6.49 | 6.55 | 6.35 | 6.35 | 6.38 | 6.35 | 6.38 | 6.23 | 6.19 | 6.24 | 6.21 | 6.21 Johnson Controls Unitary Products 9 5005562-Y TG-A-0215 DIMENSIONS к 4 y 7 +e И LALA UN U y Й LA LAL] Il // // | ИИ И И nn 7 7 UT UN ИИ, Y П “ A 7 UN ПИ 7/11 И, / IL И и ПИЛ {И с HIGH VOLTAGE | CONNECTION 7/8" | UM И UU 7 7 y 7 LA сл / ИИ U > к // Л И ПИ И * : / / IN UU + a LA / И 1 7 HIGH VOLTAGE CONNECTION 1-3/32" y / COMPRESSOR ACCESS PANEL | COIL GUARD COMBUSTION AIR INTAKE HEAT EXCHANGER ACCESS PANEL EXHAUST HOOD CONDENSATE DRAIN BLOWER ACCESS CONTROL ACCESS LOW VOLTAGE CONNECTION PANEL PANEL GAS SUPPLY A0296-001 Unit Dimensions Dimensions Model A B с 24 51 35-5/8 47 30 51 35-5/8 49 36 51 35-5/8 49 42 51 35-5/8 49 48 51 45-5/8 53 60 51 45-5/8 55 Unit Clearances’ 2 Direction Distance (in.) Direction Distance (in.) Top? 48 Power Entry (Right Side) 42 Side Opposite Ducts 36 Left Side 36 Duct Panel 12 Bottom? 1 1. A 1" clearance must be provided between any combustible material and the supply air duct work. 2. The products of combustion must not be allowed to accumulate within a confined space and recirculate. 3. Units must be installed outdoors. Over hanging structure or shrubs should not obstruct condenser air discharge outlet. 4. Units may be installed on combustible floors made from class A, B or C roof covering materials. 10 Johnson Controls Unitary Products 5005562-YTG-A-0215 INDOOR BLOWER SPECIFICATIONS Motor Model HP RPM EFF. SF Frame 24050 1/3 Variable 0.8 1.0 48 24075 1/2 Variable 0.8 1.0 48 30050 1/3 Variable 0.8 1.0 48 30075 1/2 Variable 0.8 1.0 48 36050 1/2 Variable 0.8 1.0 48 36075 1/2 Variable 0.8 1.0 48 36100 3/4 Variable 0.8 1.0 48 42075 3/4 Variable 0.8 1.0 48 42100 3/4 Variable 0.8 1.0 48 48065 3/4 Variable 0.8 1.0 48 48100 3/4 Variable 0.8 1.0 48 48125 3/4 Variable 0.8 1.0 48 60065 1 Variable 0.8 1.0 48 60100 1 Variable 0.8 1.0 48 60125 1 Variable 0.8 1.0 48 SOUND PERFORMANCE Model Sound Rating! Octave Band Centerline Frequency (Hz) (Tons) dB (A) 125 250 500 1000 2000 4000 8000 24 75 62.4 61.5 64.2 67 61 57.3 49.6 30 75 60.5 61.6 64.8 66.9 60.9 56.0 49.7 36 74 58.5 61.8 65.4 66.5 60.7 54.8 49.8 42 74 63.5 63.9 62.3 65 64 54.1 46.6 48 74 63.5 63.9 62.3 65 64 54.1 46.6 60 76 72.3 65.0 63.9 64 60 55.5 49.0 1. Rated in accordance with AHRI Standard 270. ELECTRICAL DATA Compressor OD Fan Supply MICA! Max Fuse?/ Model Voltage Motor Blower Motor Breaker? Size RLA LRA MCC FLA FLA (Amps) (Amps) 24050 208/230-1-60 8.7 450 14.4 1.3 2.6 14.8 20 24075 208/230-1-60 8.7 45.0 14.4 1.3 3.8 16.0 20 30050 208/230-1-60 9.8 57.0 15.1 1.3 2.6 16.2 25 30075 208/230-1-60 9.8 57.0 15.1 1.3 3.8 17.4 25 36050, 36075 208/230-1-60 13.0 78.0 23.0 1.3 3.8 21.4 30 36100 208/230-1-60 13.0 78.0 23.0 1.3 5.4 23.0 35 42075, 42100 208/230-1-60 20.0 112.0 28.0 1.3 54 31.7 50 48065, 48100, 48125 208/230-1-60 24.3 117.0 34.0 1.7 54 34.7 60 60065, 60100, 60125 208/230-1-60 27 1 144.2 38.0 1.7 7.0 42.6 60 1. Minimum Circuit Ampacity. 2. Maximum Over Current Protection per standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. Johnson Controls Unitary Products 11 5005562-YTG-A-0215 WEIGHTS & DIMENSIONS CENTER OF GRAVITY COMPRESSOR FRONT OF UNIT (<2 X Y DA Se A0295-001-TG Weights and Dimensions Model Weight (Ibs.) Center of Gravity 4 Point Load Location (Ibs.) Shipping Operating X Y A B C D 24050 364 359 28 14 104 89 78 88 24075 371 366 28 14 106 91 80 89 30050 384 379 27 15 105 95 87 92 30075 391 386 27 15 107 97 88 94 36050 420 415 27 16 112 102 97 104 36075 427 422 27 16 114 104 98 106 36100 431 426 27 16 116 107 98 105 42075 447 442 27 16 120 109 103 111 42100 451 446 27 16 121 111 104 111 48065 500 495 26 20 132 130 115 118 48100 508 503 26 20 134 132 117 120 48125 513 508 26 20 136 133 118 121 60065 527 522 26 21 137 134 123 127 60100 535 530 26 21 139 136 125 129 60125 540 535 26 21 141 - 138 127 129 12 Johnson Controls Unitary Products AIRFLOW PERFORMANCE Airflow - Side Duct Application 5005562-Y TG-A-0215 External Static Pressure (Inches WC) Model Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 | SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 732 667 624 567 517 470 415 369 Low/Medium (2) 818 771 723 674 628 579 530 482 24050 Medium (3) 823 774 721 676 631 583 533 505 Medium/High (4) 994 948 906 865 823 778 739 700 High (5) 1148 1108 1071 1035 996 960 925 901 Low (1) 887 847 802 750 705 664 613 563 Low/Medium (2) 978 941 898 850 803 759 713 667 24075 Medium (3) 1171 1114 1074 1039 993 949 906 864 Medium/High (4) 1349 1297 1265 1224 1185 1146 1107 1063 High (5) 1487 1462 1392 1331 1318 1281 1241 1201 Low (1) 700 657 599 554 512 461 411 365 Low/Medium (2) 906 868 825 779 735 692 650 608 30050 Medium (3) 992 951 911 868 826 787 747 712 Medium/High (4) 1075 1032 1000 958 918 874 837 800 High (5) 1136 1089 1053 1018 978 941 903 869 Low (1) 1076 1020 984 943 903 859 819 779 Low/Medium (2) 1102 1048 1010 974 934 890 850 810 30075 Medium (3) 1191 1140 1112 1076 1038 1000 958 919 Medium/High (4) 1201 1225 1187 1151 1118 1080 1041 1002 High (5) 1370 1329 1283 1271 1209 1176 1143 1109 Low (1) 1003 952 904 851 790 730 674 633 Low/Medium (2) 1180 1133 1085 1042 995 942 889 834 36050 Medium (3) 1259 1209 1166 1126 1084 1032 980 928 Medium/High (4) 1314 1271 1229 1186 1144 1097 1049 998 High (5) 1506 1471 1403 1389 1345 1305 1262 1216 Low (1) 1225 1174 1131 1090 1046 993 941 888 Low/Medium (2) 1259 1209 1166 1126 1084 1032 980 928 36075 Medium (3) 1314 1271 1229 1186 1144 1097 1049 998 Medium/High (4) 1348 1306 1259 1222 1179 1133 1086 1036 High (5) 1506 1471 1403 1389 1345 1305 1262 1216 Low (1) 1342 1302 1260 1217 1178 1134 1082 1034 Low/Medium (2) 1425 1368 1332 1293 1251 1208 1163 1113 36100 Medium (3) 1554 1503 1465 1423 1386 1346 1302 1257 Medium/High (4) 1658 1599 1588 1530 1495 1454 1414 1373 High (5) 1966 1914 1862 1810 1757 1705 1653 1600 Low (1) 1315 1266 1229 1194 1156 1117 1080 1036 Low/Medium (2) 1436 1382 1342 1304 1262 1220 1179 1131 42075 Medium (3) 1458 1406 1365 1327 1286 1244 1203 1155 Medium/High (4) 1573 1523 1484 1445 1408 1367 1327 1279 High (5) 1966 1914 1862 1810 1757 1705 1653 1600 Low (1) 1436 1382 1342 1304 1262 1220 1179 1131 Low/Medium (2) 1544 1492 1455 1416 1376 1336 1294 1248 42100 Medium (3) 1573 1523 1484 1445 1408 1367 1327 1279 Medium/High (4) 1681 1640 1599 1557 1517 1478 1436 1393 High (5) 1935 1887 1834 1788 1743 1701 1651 1591 Low (1) 1046 1009 980 946 915 878 844 779 Low/Medium (2) 1295 1250 1213 1172 1133 1087 1045 964 48065 Medium (3) 1620 1564 1517 1466 1418 1360 1308 1206 Medium/High (4) 1798 172? 1669 1620 1572 1527 1480 1413 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 Continued on next page. Johnson Controls Unitary Products 13 5005562-Y TG-A-0215 Airflow - Side Duct Application (Continued) External Static Pressure (Inches WC) Model Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 1620 1564 1517 1466 1418 1360 1308 1206 Low/Medium (2) 1694 1630 1580 1530 1482 1430 1380 1292 48100 Medium (3) 1798 1722 1669 1620 1572 1527 1480 1413 Medium/High (4) 1835 1758 1703 1653 1604 1558 1511 1442 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 Low (1) 1620 1564 1517 1466 1418 1360 1308 1206 Low/Medium (2) 1798 1722 1669 1620 1572 1527 1480 1413 48125 Medium (3) 1922 1803 1804 1754 1724 1658 1612 1559 Medium/High (4) 2001 1952 1890 1839 1820 1742 1696 1651 High (5) 2146 2085 2025 1960 1872 1862 1798 1735 Low (1) 1073 1043 1009 988 963 941 917 892 Low/Medium (2) 1329 1292 1250 1223 1192 1165 1136 1105 60065 Medium (3) 2054 1998 1934 1890 1843 1801 1757 1710 Medium/High (4) 2195 2144 2098 2049 2003 1955 1883 1868 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 Low (1) 1730 1682 1628 1592 1552 1517 1479 1439 Low/Medium (2) 1858 1807 1749 1710 1667 1629 1589 1546 60100 Medium (3) 2054 1998 1934 1890 1843 1801 1757 1710 Medium/High (4) 2195 2144 2098 2049 2003 1955 1883 1868 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 Low (1) 2063 2008 1943 1899 1851 1809 1763 1717 Low/Medium (2) 2130 2084 2032 1983 1927 1951 1860 1815 60125 Medium (3) 2195 2144 2098 2049 2003 1955 1883 1868 Medium/High (4) 2275 2252 2169 2154 2112 2065 1989 1976 High (5) 2445 2388 2306 2293 2235 2178 2129 2077 14 aa WN . Airflow tested with dry coil conditions, without air flitters, at 230 volts . Applications above 0.8" w.c. external static pressure are not recommended. . Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. . Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. . Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products Airflow - Bottom Duct Application 5005562-YTG-A-0215 — External Static Pressure (Inches WC) Model Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 754 710 665 611 — 560 491 445 391 Low/Medium (2) 867 815 773 720 677 622 559 505 24050 Medium (3) 951 908 868 828 781 735 686 631 Medium/High (4) 1024 982 942 902 861 817 775 721 High (5) 1204 1159 1121 1085 1051 1013 975 938 Low (1) 899 869 827 782 734 685 630 575 Low/Medium (2) 1033 960 924 879 834 787 735 685 24075 Medium (3) 1186 1133 1095 1056 1016 975 935 891 Medium/High (4) 1357 1322 1284 1248 1211 1174 1127 1087 High (5) 1480 1439 1404 1367 1369 1299 1264 1226 Low (1) 726 676 622 575 520 467 410 376 Low/Medium (2) 928 886 841 795 745 706 658 607 30050 Medium (3) 1021 983 942 900 855 811 770 729 Medium/High (4) 1109 1071 1029 995 949 908 864 826 High (5) 1170 1134 1096 1061 1020 978 938 899 Low (1) 1076 1042 1009 969 930 890 849 808 Low/Medium (2) 1104 1063 1025 987 947 908 869 830 30075 Medium (3) 1205 1170 1136 1098 1060 1025 985 943 Medium/High (4) 1285 1251 1213 1179 1141 1104 1065 1027 High (5) 1406 1375 1341 1306 1271 1236 1198 1163 Low (1) 1008 962 916 861 807 757 700 650 Low/Medium (2) 1190 1148 1106 1055 1008 955 914 863 36050 Medium (3) 1262 1223 1181 1137 1091 1044 994 952 Medium/High (4) 1324 1282 1245 1202 1161 1112 1067 1018 High (5) 1517 1475 1447 1400 1357 1318 1275 1232 Low (1) 1231 1186 1146 1103 1069 1030 977 912 Low/Medium (2) 1270 1225 1189 1140 1098 1046 1008 960 36075 Medium (3) 1317 1286 1245 1198 1151 1110 1064 1024 Medium/High (4) 1358 1317 1275 1238 1197 1148 1105 1057 High (5) 1517 1475 1447 1400 1357 1318 1275 1232 Low (1) 1340 1299 1264 1224 1182 1182 1097 1049 Low/Medium (2) 1409 1368 1334 1291 1253 1201 1173 1128 36100 Medium (3) 1527 1492 1470 1419 1385 1343 1299 1250 Medium/High (4) 1663 1585 1594 1601 1521 1480 1440 1400 High (5) 1930 1892 1853 1805 1760 1696 1625 1553 Low (1) 1332 1295 1263 1222 1185 1148 1110 1063 Low/Medium (2) 1457 1419 1376 1340 1299 1253 1215 1160 42075 Medium (3) 1451 1412 1371 1339 1296 1257 1211 1165 Medium/High (4) 1568 1524 1491 1464 1425 1383 1345 1296 High (5) 1978 1937 1891 1837 1785 1725 1656 1604 Low (1) 1455 1414 1379 1335 1294 1254 1212 1160 Low/Medium (2) 1566 1532 1492 1455 1416 1372 1333 1280 42100 Medium (3) 1565 1530 1491 1458 1419 1381 1336 1290 Medium/High (4) 1675 1641 1606 1578 1535 1495 1455 1412 High (5) 1946 1909 1863 1815 1771 1721 1654 1595 Low (1) 1032 999 970 938 910 879 843 808 Low/Medium (2) 1272 1236 1204 1165 1129 1081 1037 968 48065 Medium (3) 1611 1574 1518 1494 1439 1405 1357 1266 Medium/High (4) 1892 1777 1771 1701 1639 1617 1565 1489 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 Continued on next page. Johnson Controls Unitary Products 15 5005562-Y TG-A-0215 Airflow - Bottom Duct Application (Continued) External Static Pressure (Inches WC) Model Motor Speed 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 SCFM SCFM SCFM SCFM SCFM SCFM SCFM SCFM Low (1) 1598 1548 1502 1454 1410 1362 1307 1251 Low/Medium (2) 1663 1612 1568 1522 1476 1422 1370 1297 48100 Medium (3) 1789 1733 1670 1650 1596 1578 1535 1483 Medium/High (4) 1931 1814 1808 1736 1673 1650 1597 1519 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 Low (1) 1598 1548 1502 1454 1410 1362 1307 1251 Low/Medium (2) 1766 1703 1656 1611 1566 1518 1469 1419 48125 Medium (3) 1912 1875 1805 1787 1750 1713 1672 1636 Medium/High (4) 2105 2014 2006 1931 1898 1845 1793 1739 High (5) 2131 2058 1998 1949 1892 1840 1788 1728 Low (1) 1026 999 989 950 907 907 886 862 Low/Medium (2) 1263 1230 1192 1165 1167 1101 1099 1071 60065 Medium (3) 1987 1933 1861 1817 1820 1715 1725 1651 Medium/High (4) 2114 2050 2047 1974 1899 1889 1920 1866 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 Low (1) 1655 1612 1596 1531 1461 1462 1429 1391 Low/Medium (2) 1766 1720 1667 1629 1632 1539 1537 1498 60100 Medium (3) 1987 1933 1861 1817 1820 1715 1725 1651 Medium/High (4) 2114 2050 2047 1974 1899 1889 1920 1866 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 Low (1) 1973 1924 1905 1826 1743 1744 1703 1660 Low/Medium (2) 2024 1983 1937 1889 1886 1843 1799 1759 60125 Medium (3) 2123 2075 2019 1970 1978 1862 1849 1804 Medium/High (4) 2191 2154 2117 2075 2002 1995 2028 1974 High (5) 2369 2308 2249 2183 2126 2088 2034 1990 16 NS 3 N = . Airflow tested with dry coil conditions, without air flitters, at 230 volts . Applications above 0.8" w.c. external static pressure are not recommended. . Brushless DC high efficiency standard ECM blower motor used for all indoor blower assemblies. . Minimal variations in airflow performance data results from operating at 208 volts. Data above may be used in those cases. . Heating applications tested at 0.50" w.c. esp, and cooling applications tested at 0.30" w.c.esp per standards. Johnson Controls Unitary Products 5005562-Y TG-A-0215 BOTTOM DUCT DIMENSIONS (Inches) REAR DUCT DIMENSIONS (Inches) pe 16 — » — > — — 4 00 — №4 > — — № © 00 e | LR А0298-001 A0289-001 Model A B С D Model A B 24, 30, 36, 42 10 21.5 4.94 4.34 24, 30, 36, 42 9.6 22 48, 60 14 13.5 5 3.56 48, 60 13.6 14 ROOF CURB INSTALLATION ROOF CURB REAR DUCT INSTALLATION BOTTOM DUCT SLAB ON GROUND INSTALLATION AO324-001 Johnson Controls Unitary Products 17 UNIT TYPICAL SLAB ON GROUND INSTALLATION (Gas model shown) TO POWER SUPPLY A U) Y 7 UA \ 77 + RETURN > 4" AIR DUCT 77 27777 EN Л | Z Z N — SUPPLY AIR DUCT IL NN FIELD-SUPPLIED DISCONNECT || SWITCH / 77 CONDENSATE DRAIN \ MANUAL GAS SHUTOFF VAVLE CONTROL WIRING TO INDOOR THERMOSTAT TO GAS SUPPLY LINE A0325-001 UNIT TYPICAL ROOF CURB INSTALLATION (Gas model shown) \ ММ МК A М | VO И 7 7 0% | 2 FIR Un | UD, BT И 7 7 y Я 0% 7 PA da Di UA ZR 2 / HTH М ln | ROOF CONDENSATE DRAIN Ут ROOF CURB MANUAL GAS — SHUTOFF VAVLE ZI pe FIELD-SUPPLIED > DISCONNECT = — SWITCH TO GAS <> SUPPLY LINE > TO POWER SUPPLY A CONTROL WIRING TO _/ INDOOR THERMOSTAT RETURN f Se AIR DUCT SUPPLY AIR DUCT A0326-001 Subject to change without notice. Published in U.S.A. 5005562-Y TG-A-0215 Copyright © 2015 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing York International Corp. 5005 York Drive Norman, OK 73069
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement