AY-x25 Family
Mifare® ID Read-Only
Proximity Reader
Installation & Operational Manual
Models:
AY-H25
AY-K25
AY-M25
March 2008
Table of Contents
Table of Contents
1.
Introduction...................................................................... 3
1.1
General Specifications.............................................. 3
1.2
Supported Transponders ........................................... 4
2.
Technical Specifications .................................................. 5
3.
Installation........................................................................ 6
3.1
The Installation Kit................................................... 6
3.2
Installing the AY-x25 Reader:.................................. 6
4.
Wiring Instructions.......................................................... 8
5.
Operation Instructions .................................................. 10
Appendix A.
Limited Warranty ................................... 11
Appendix B.
Technical Support ................................... 13
AY-x25 Installation & Operating Manual
Page ii
Introduction
1. Introduction
The AY-x25 Prox Reader is a MIFARE® ID Read-only family of proximity
readers that are intended primarily for use in access control system
applications. The AY-x25 family reads the MIFARE® Card Identification
Number and transmits it to the access control system, using multiformats common Wiegand interface.
1.1 General Specifications
•
Contact-less Smart Card Reader
•
Reads MIFARE® serial number only
•
Meets ISO14443 Type A Standard
•
Operation Frequency — 13.56MHz, Bit rate — 106KHz
•
Read Range — approximately 25mm to 70mm with proximity
card Transponder
•
Output format and configurations upgrade via PC software (Set
by Factory)
o
Wiegand 26 bit (default)
o
Wiegand 26 bit with facility code output format
o
Wiegand 32 bit
o
Wiegand 32 bit reverse output
o
Wiegand 34 bit
o
Wiegand 40 bit
o
Clock & Data
•
Optical Back Tamper Sensor and open collector tamper output
•
LED Buzzer control input (set by factory)
•
Bi-Colored LED
Page 3
AY-x25 Installation & Operating Manual
Introduction
1.2 Supported Transponders
•
MIFARE® Ultralight 512-bit EEPROM
•
MIFARE® Classic 1Kbytes memory
•
MIFARE® Classic 4Kbytes memory
Note:
Mifare Ultra light 512 bit EEPROM is partly
supported. Only 32 bits out of the 56 bits can be
transmitted.
AY-x25 Installation & Operating Manual
Page 4
Technical Specifications
2. Technical Specifications
Electrical Characteristics
Specifications
AY-M25
AY-K25
AY-H25
Linear type – recommended
Power Supply
Type
5-16VDC
Operating
Voltage Range
18VDC
Absolute
Maximum (nonoperating)
Current @ 12V
Standby: 45mA
Read: 60mA
Standby: 53mA
Read: 57mA
Standby: 54mA
Read: 63mA
Read Range*
65mm (2.55'')
50mm (1.96'')
55mm (2.16'')
LED Control Input
Dry Contact, N.O.
Tamper Output
Open collector, active low, max. sink current 30mA
500ft (150 meters)
Maximum Cable
Distance to
Controller
Environmental Characteristics
-31°C to 63°C (25°F to 145°F)
Operating Temp.
Range
0 – 95% (non-condensing)
Operating
Humidity
Dimensions
HxWxD
88.9x88.9x15mm
(3.5x3.5x0.59'')
79.9x39.9x12.8mm 109.9x74.9x15mm
(3.15x1.57x0.50'')
(4.33x2.95x0.59'')
Weight
116g (0.255lbs)
69g (0.152lbs)
114g (0.251lbs)
* Range depends on the electrical environment and proximity to metal measured
with Rosslare's MIFARE® Classic 1Kbytes cards.
Page 5
AY-x25 Installation & Operating Manual
Installation
3. Installation
3.1 The Installation Kit
The Installation kit comprises the following items that are to be used
during the installation procedure:
•
One Mounting Template
•
Two pan head screws & wall plugs
•
One L shaped security screw tool
• One security screws
3.2 Installing the AY-x25 Reader:
1.
Determine an approximate location for the Reader.
2.
Peel off the back of the self-adhesive mounting label template
and place it at the required mounting location.
3.
Using the template as a guide, drill two holes (sizes indicated on
the template) used for mounting the Reader onto the surface,
4.
Insert a suitable wall plug into each hole.
5.
Drill a 7/16” (10mm) hole for the cable. If mounting on metal,
place a grommet or electrical tape around the edge of the hole.
6.
Route the interface cable from the Reader to the Controller. A
linear type power supply is recommended.
7.
Remove the Reader's snap-off front cover to reveal the two
screw holes, see figure below.
AY-x25 Installation & Operating Manual
Page 6
Installation
Figure 1: Removing the Top Cover
8.
Align the two holes of the Reader with those drilled in the wall
and firmly attach the Reader to the wall with two screws, whose
size is indicated on the template.
9.
Relocate the front cover onto the Reader.
Note:
The Reader can also be mounted using strong
epoxy glue. After application, the Reader should
be firmly held in place until the glue dries
Page 7
AY-x25 Installation & Operating Manual
Wiring Instructions
4.
Wiring Instructions
The AY-x25 is supplied with an 18” pigtail, comprising a 6-conductor
cable.
To connect the Reader to the Controller:
1.
Prepare the Reader cable by cutting its jacket back 1¼" and strip
the insulation from the wires, ½".
2.
Prepare the Controller cable by cutting its jacket back 1¼" and
strip the insulation from the wires, ½".
3.
Splice the Reader’s pigtail wires to the corresponding Controller
wires (as indicated in the following table) and cover each joint
with insulating tape.
If the tamper output is being utilized, connect the purple wire to
the correct input on the Controller.
The LED control may be configured by the factory to function
either as a LED control or as buzzer control. When connecting the
wire to “Ground” it will activate the function continuously, either
continuous LED or continuous Buzzer
4.
Color
Output
Red
Black
White
Green
Brown
Purple
5-16VDC
Ground
Data 1/Clock
Data 0/Data
LED/buzzer Control
Tamper
Trim and cover all unused conductors.
AY-x25 Installation & Operating Manual
Page 8
Wiring Instructions
Note:
Page 9
•
The individual wires from the Reader are color-coded
according the Wiegand standard.
•
When using a separate power supply for the Reader,
this supply and that of the Controller must have a
common ground.
•
The Reader’s cable shield wire should be preferably
attached to an earth ground, or a signal ground
connection at the panel, or power supply end of the
cable. This configuration is best for shielding the
Reader cable from external interference.
AY-x25 Installation & Operating Manual
Operation Instructions
5.
Operation Instructions
The Reader should be tested after wiring it to a power supply and
the Controller.
To test the Reader:
1.
Power up the Reader. The LED flashes green and the Beeper
sounds, three times, thus indicating that the Reader is
working properly. The LED returns to its idle state (red).
2.
Present the appropriate type of proximity card to the
Reader. The LED will momentarily flash green and a short
beep is emitted, thus indicating that the card was read
properly by the Reader.
The Reader transmits the card's data to the Controller. The
Controller checks the data and if it is valid, the LED will
change momentarily to green. It then returns to its idle state
(red).
AY-x25 Installation & Operating Manual
Page 10
Limited Warranty
Appendix A. Limited Warranty
ROSSLARE ENTERPRISES LIMITED S (Rosslare) TWO YEARS LIMITED WARRANTY
is applicable worldwide. This warranty supersedes any other warranty. Rosslare's TWO
YEARS LIMITED WARRANTY is subject to the following conditions:
Warranty
Warranty of Rosslare's products extends to the original purchaser (Customer) of the
Rosslare product and is not transferable.
Products Covered By This Warranty and Duration
ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that
the AY-x25 MIFARE® Serial Number only proximity card Reader, to be free from defects in
materials and assembly in the course of normal use and service. The warranty period
commences with the date of shipment to the original purchaser and extends for a period of
2 years (24 Months).
Warranty Remedy Coverage
In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the
Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by
the Customer during the warranty period in accordance with the terms of this warranty.
Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR
SUBSIDIARIES representative, return of the failed product(s) is not immediately required.
If ROSSLARE has not contacted the Customer within a sixty (60) day holding period
following the delivery of the warranty claim, Customer will not be required to return the
failed product(s). All returned Product(s), as may be requested at ROSSLARE
ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property
of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES.
To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an
RMA number after which, the product must be returned to the Manufacturer freight prepaid
and insured
In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day
holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be
applied to each Product for labor required in the evaluation.
Rosslare will repair or replace, at its discretion, any product that under normal conditions
of use and service proves to be defective in material or workmanship. No charge will be
applied for labor or parts with respect to defects covered by this warranty, provided that
the work is done by Rosslare or a Rosslare authorized service center.
Page 11
AY-x25 Installation & Operating Manual
Limited Warranty
Exclusions and Limitations
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the
operation or performance of any Product or any systems in which a Product is
incorporated. This warranty shall not extend to any ancillary equipment not furnished by
ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product
that is used with any ancillary equipment, which is not furnished by ROSSLARE.
This warranty does not cover expenses incurred in the transportation, freight cost to the
repair center, removal or reinstallation of the product, whether or not proven defective.
Specifically excluded from this warranty are any failures resulting from Customer's
improper testing, operation, installation, or damage resulting from use of the Product in
other than its normal and customary manner, or any maintenance, modification, alteration,
or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal
wear, defects or damage due to lightning or other electrical discharge. This warranty does
not cover repair or replacement where normal use has exhausted the life of a part or
instrument, or any modification or abuse of, or tampering with, the Product if Product
disassembled or repaired in such a manner as to adversely affect performance or prevent
adequate inspection and testing to verify any warranty claim.
ROSSLARE does not warrant the installation, maintenance, or service of the Product.
Service life of the product is dependent upon the care it receives and the conditions under
which it has to operate.
In no event shall Rosslare be liable for incidental or consequential damages.
Limited Warranty Terms
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD. AND
IT’S SUBSIDIARIES’S WARRANTY
THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR
NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE.
THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE
SPECIFICALLY EXCLUDED.
IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE
PURCHASE PRICE OF THE PRODUCT, OR FOR ANY OTHER INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF
USE, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND LOSS OF PROFITS,
ARISING OUT OF THE INSTALLATION, USE, OR INABILITY TO USE SUCH PRODUCT, TO
THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW.
THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE
PROVISIONS OF THIS LIMITED WARRANTY.
AY-x25 Installation & Operating Manual
Page 12
Technical Support
Appendix B. Technical Support
Asia Pacific, Middle East
Rosslare Security Products Headquarters
905-912 Wing Fat Industrial Bldg,
12 Wang Tai Road,
Kowloon Bay Hong Kong
Tel: +852 2795-5630
Fax: +852 2795-1508
E-mail: support.apac@rosslaresecurity.com
United States and Canada
1600 Hart Court, Suite 103
Southlake, TX, USA 76092
Tool Free:+1-866-632-1101
Local:+1-817-305-0006
Fax: +1-817-305-0069
E-mail: support.na@rosslaresecurity.com
Europe, Africa
Global Technical Support & Training Center
HaMelecha 22
Rosh HaAyin, Israel 48091
Tel: +972 3 938-6838
Fax: +972 3 938-6830
E-mail: support.eu@rosslaresecurity.com
South America
Pringles 868, 1640 Martinez
Buenos Aires
Argentina
Tel: +54 11 4798-0095
Fax: +54 11 4798-2228
E-mail: support.la@rosslaresecurity.com
Web Site: www.rosslaresecurity.com
Page 13
AY-x25 Installation & Operating Manual
0706-0960191+00
www.rosslaresecurity.com