Power VI-GL
Assembly & Use Instructions
™
For 220v Models
FULL
W
AR
Y
2 YEAR
RA N
T
* Specifications may vary from this image and
are subject to change without notice.
The Power VI-GL is shown here.
Your actual model may vary.
To download and print Teeter’s Power VI-GL instructions, visit the product support page at teeter.com.
EN
ATTENTION FACILITY USE PERSONNEL
The Teeter Power VI-GL Inversion Table is commercial- grade equipment intended for use in fitness facilities. In this manual, you
will find important information how to assemble, maintain and use the inversion table. The Power VI-GL inversion Table provides
progressive decompression to help relieve back pain by releasing tension and stress, rejuvenating discs, and reducing nerve pressure.
Motorized operation with simple one-button control enables smooth and accurate rotation. Perform advanced exercises to train
core muscle groups through inverted sit-ups and squats. See back of table bed for illustrated advanced exercises that may be
performed on the inversion table.
To register your product warranty, go to teeter.com/Support/Warranty-Registration
If you have any questions concerning assembly or if any parts are missing, DO NOT RETURN THE ITEM TO THE STORE OR
CONTACT THE RETAILER. Our dedicated customer service experts can help! Contact Teeter Customer Service at 800.847.0143, or via online forms or Live Chat at teeter.com.
Safety & Assembly Instructions
Use Instructions
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . 1-3
Prepare to Invert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
General Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
How to Invert . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Voltage information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Full Inversion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Grounding Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 2
Returning Upright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Choosing & Preparing a Site . . . . . . . . . . . . . . . . . . . . 2
Product Maintenance & Cleaning . . . . . . . . . . . . . . . 2
Proper Training of Facility Staff . . . . . . . . . . . . . . . . . . 2
Emergency Dismount Instructions . . . . . . . . . . . . . .3
Items for Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Understanding Your Inversion Table . . . . . . . . . . . . . . . . . 5
Safety Warning Labels & Product Specifications . . . . . 6
Technical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Assembly Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
BEFORE YOU BEGIN: Review all steps before beginning assembly and read all precautions before using the Power VI-GL Inversion
Table. Carefully adhere to the Assembly and User Instructions to help ensure safety and product integrity.
™
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE INVERSION TABLE
Type B
Refer to
Instruction Manual
!
Operating
Instructions
Carefully review prior
to using equipment
WARNING
FAILURE TO FOLLOW INSTRUCTIONS AND WARNINGS COULD RESULT IN SERIOUS INJURY OR DEATH.
To reduce the risk of burns, fire, electric shock, or injury to persons:
•Read and understand all the instructions, receive proper training on use of the equipment from facility staff, and inspect the equipment
before using the inversion table. It is your responsibility to familiarize yourself with the proper use of this equipment and the inherent risks of
inversion if these instructions are not followed, such as falling on your head or neck, pinching, entrapment, equipment failure, or aggravating a
pre-existing medical condition.
•DO NOT use the equipment without a licensed physician’s approval. Carefully review the following list of medical contraindications for
inversion with all users (this is not an exhaustive list, it is intended only for reference):
•Middle ear infection
•Extreme obesity
•Pregnancy
•Hiatal or ventral hernia
•Eye conditions like glaucoma,
retinal detachment or
conjunctivitis
•Chronic sinusitis
•High blood pressure or
hypertension
•Heart or circulatory disorders
•Use of anticoagulants (including
high doses of aspirin)
•Weakness, frailty, or mobility
issues
•Dizziness, trouble with
coordination or head-down
disorientation
•Vertigo, motion sickness or inner
ear disorders
•Brain injury or recent head
trauma
•Recent stroke or transient
ischemic attack
•Spinal injury or conditions
impacting the spinal cord
•Cerebral sclerosis
•Medical conditions associated
with the weight-bearing joints
•Acutely swollen joints
•Bone weakness (osteoporosis)
•Recent or unhealed fractures
•Medullary pins or surgically
implanted orthopedic supports
•Any other medical condition that
may be made more severe by
an elevation of blood pressure,
intracranial pressure or the
mechanical stress of the inverted
position
•ALWAYS ensure that the Ankle Lock System is properly adjusted and fully engaged, and that ankles are secure before using the equipment.
HEAR, FEEL, SEE and TEST that the Ankle Lock System is snug, close-fitting and secure EVERY TIME before using the equipment.
•ALWAYS wear securely tied lace-up shoes with a flat sole, such as a normal tennis-style shoe. DO NOT wear any footwear that could interfere
with securing the Ankle Lock System, such as shoes with thick soles, boots, high-tops or any shoe that extends above the anklebone.
•ALWAYS test the inversion table each time prior to mounting by pressing the Rotation Button to ensure that it rotates smoothly.
•ALWAYS ensure there is a spotter present who is capable of returning the user to the upright position using the emergency crank in the
event of a power outage.
• ALWAYS review the emergency dismount instructional label located on the motor housing prior to inverting. Ensure that the emergency
crank is in its storage position and NOT engaged in the motor during normal use.
•ALWAYS return the inversion table to the upright position after each use so that the main shaft is resting against the crossbar.
•DO NOT continue using the equipment if you feel pain or become light-headed or dizzy while inverting. Immediately return to the upright
position for recovery and eventual dismount.
•DO NOT use if you are over 6 ft 6 in (198 cm) or over 300 lbs. (136 kg). Structural failure could occur or head/neck may impact the floor
during inversion.
•DO NOT allow children to use this machine. The inversion table is not intended for use by persons with reduced physical, sensory or
mental capabilities.
• ALWAYS ensure the inversion table is clear of walls, equipment and other hard surfaces before operating. Keep children, bystanders, and pets
away from machine while in use.
•DO NOT use aggressive movements, or use weights, elastic bands, any other exercise or stretching device or non-Teeter® attachments while
on the inversion table. Use the inversion table only for its intended use as described in these instruction.
•DO NOT drop or insert any object into any opening. Keep body parts, hair, loose clothing and jewelry clear of all moving parts.
DO NOT operate the inversion table if the air openings are blocked.
•Equipment is not intended for continuous rotation. Recommended duty cycle is 30 seconds ON, 3 minutes OFF.
•DO NOT operate equipment while under the influence of drugs, alcohol, or medication that may cause drowsiness or disorientation.
FACILITY SAFETY INSTRUCTIONS
•It is the responsibility of the facility to evaluate their own clientele to determine who should and should not use the equipment and ensure
that all users are fully informed about the proper use of the inversion table, health contraindications, and all safety precautions prior to use.
Ensure that these instructions are available to users.
• ALWAYS unplug from the electrical outlet immediately after using and before cleaning or servicing.
•ALWAYS inspect the equipment prior to use. Schedule routine equipment inspections to verify that the unit is clean and functions properly,
all parts rotate smoothly, and all fasteners are secure. Cycle the equipment through one complete inversion.
• ALWAYS set up and operate the inversion table in an area with sufficient clearance on all sides of the unit. ALWAYS ensure the inversion table
is clear of walls, equipment and other hard surfaces before operating. Users will require adequate space to rotate the table.
•DO NOT operate the equipment if: (1) the cord is damaged; (2) the inversion table is not working properly or (3) if the inversion table has been
dropped or damaged. DO NOT place the cord near heated surfaces or sharp edges.
• KEEP DRY - DO NOT operate the equipment near saunas or pools. DO NOT operate where aerosol (spray) products are being used or where
oxygen is being administered. DO NOT use outdoors.
• ALWAYS position equipment on a level surface and away from water or ledges that could lead to accidental immersion or falls.
•If the equipment is damaged or inoperable, unplug and keep out of use until repair. DO NOT attempt to repair the equipment - there are no
user serviceable parts and is not field serviceable. Contact Teeter Customer Support for service. ALWAYS dispose of per local regulations.
•If a product label or Assembly & User Instructions should become lost, damaged or illegible, contact Customer Service for replacement.
SAVE THESE INSTRUCTIONS
1
Important Safety Instructions
VOLTAGE INFORMATION
• The power requirement for the Teeter Power VI Inversion Table include a grounded, dedicated circuit with a nominal voltage of 220
VAC at 50 Hz. Voltage requirements are also located on the serial number decal on the inversion table.
!
WARNING
To avoid the risk of electric shock, ALWAYS connect to a supply mains with protective earth that matches the voltage
requirements of the inversion table that has been received. DO NOT attempt to use this unit with a voltage adapter. DO NOT
attempt to use this unit with an extension cord. DO NOT plug more than one unit into a single circuit. ALWAYS ensure that
the inversion table is connected to an outlet having the same configuration as the plug. DO NOT use a ground plug adapter to
adapt the power cord to a non-grounded outlet.
GROUNDING INSTRUCTIONS
• The Power VI Inversion Table must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all
local codes and ordinances.
!
WARNING
ALWAYS ensure the equipment is properly grounded to avoid risk of serious injury or death. ALWAYS check with a qualified
electrician or service provider if there is doubt as to whether the inversion table is properly grounded. Improper connection
of the equipment grounding conductor can result in a risk of electric shock.
CHOOSING & PREPARING A SITE
• Before assembling the inversion table, a suitable site must be selected and have the proper electrical outlet power available for optimum
operation and safety. See the Voltage Information section on this page to determine the inversion table's voltage requirements. Note the
Technical Description on pg. 6 for optimum performance.
• The area selected for the inversion table should be well lit and well ventilated. Locate the inversion table on a structurally sound and level
surface with ample clearance from walls and other equipment. Users will require adequate space to rotate the table. In front of the
inversion table should have a 43 in (109.2 cm) minimum space. Behind the inversion table should be 33 in (83.8 cm) minimum of space.
Allow enough clearance for safe access and passage during use of the machine.
• Do not install the inversion table in an area of high humidity, such as in the vicinity of a steam room, sauna, indoor pool, or outdoors.
Exposure to extensive water vapor, chlorine, and/or bromine could adversely affect the performance of the machine.
•If possible, set up the product at or near the space in which you intend to use it to avoid moving it later.
PRODUCT MAINTENANCE & CLEANING
• Facilities are responsible for the cleaning and maintenance of the equipment. All maintenance activities shall be performed by qualified
personnel.
• Regularly wipe down the unit with mild soap and water. DO NOT use abrasive cleaners or solvents.
• Schedule routine equipment inspections to verify that the unit is clean and functions properly, all parts rotate smoothly, and all fasteners
are secure. Cycle the equipment through one complete inversion.
!
WARNING
To avoid the risk of serious injury or death, ALWAYS ensure that all controls are turned to the OFF position and remove the plug from
the outlet immediately after using and before cleaning or servicing.
2
Important Safety Instructions
PROPER TRAINING OF FACILITY STAFF
• Facilities are responsible for evaluating their own clientele to determine who should and should not use the equipment. It is also the
facility's responsibility to review the health contraindications, safety, and user instructions with all users prior to allowing them access to
the equipment. Ensure that this manual is available to users.
• All facility staff should be trained to perform the Emergency Dismount Instructions below in order to return the user to the upright position
in the event of a power outage or other event that prevents the motor from returning the Table Bed upright.
EMERGENCY DISMOUNT INSTRUCTIONS
FIGURE A
• Only use the Emergency Crank if the motor is rendered ineffective.
• Reach for the Emergency Crank stored beneath the motor housing on
the left side of the inversion table.
• Insert the Emergency Crank into the hole on the motor housing and
turn the crank counter clockwise (Figure A) to rotate the Table Bed to
the upright position.
IMPORTANT: During normal use, ensure that the Emergency Crank is
in its storage position and NOT engaged in the motor.
Storage
Position
3
Items for Assembly
Items not shown to scale. Hardware drawings located on the insert inside each Hardware Kit.
ITEM NO.
ITEM NAME
Table Frame & Base Assembly
P12002
Base Platform
P12001
Frame pre-assembled Table Bed
Main Shaft Assembly
P19521
Main Shaft with Ankle Lock System
P11003
Locking Knobs (2)
Handle Assembly
P12003
Handles (2)
Tools Required for Assembly: 19mm wrench
Base Platform
Main Shaft Assembly
P12002
Table Frame Assembly
Use with Base Assembly
Hardware Kit (H11601)
P19521
P12001
Locking Knobs
P11003
Handle Assembly
P12003
4
Identifying Parts & Components
Before reading further, study the drawing below to familiarize yourself with the
important components of the Power VI-GL Inversion Table.
1
3
2
4
5
10
7
9
6
8
11
Identifying Parts and Components
1
Table Bed
7
Ankle Lock System
2
Rotation Control Button
8
Foot Platform
3
Handles
9
Main Shaft
4
Motor Housing
10
Crossbar
5
Manual Hand Crank
11
Base Platform
6
Frame
5
Safety Warning Labels & Product Specifications
Important: Please review all labels and supporting materials before using your inversion table.
This drawing indicates the locations of the warning labels and placards found on your product. If a label or placard is missing,
illegible or is removed, contact Teeter Customer Service to request a complimentary replacement.
ATTENTION
Storage
Position
If a power failure occurs,
remain calm. Reach for the
emergency crank stored
beneath the motor housing.
Insert the crank into the hole
at the motor end and turn the
crank counterclockwise to
rotate the table upright. DO
NOT leave crank engaged in
motor during normal use.
61.0 in (154.9 cm)
Replace labels if damaged, illegible or removed.
LP1022 0316-4
9902 162nd St Ct E,
Puyallup, WA 98375
800.847.0143
teeter.com
Power VI-GL™
PRODUCT NO: M11023
OUTPUT: 220VAC 50Hz 120W
MADE IN KOREA & TAIWAN
Use your
smartphone
to access
instructions.
U.S. Patent 7081073B1
SERIAL # S LP1085 0416-0
54.5 in (138.4 cm)
35.3 in (89.5 cm)
LP1089 0416-0
TECHNICAL DESCRIPTION
6
Assembled Non-Use Dimensions:
54.5 (L) x 35.3 (W) x 61.0 in (H) (138.4 x 89.5 x 154.9 cm)
Maximum In-Use Dimensions:
75.0 (L) x 35.3 (W) x 88.0 in (H) (190.5 x 89.5 x 223.5 cm)
Weight (approx.):
161 lbs (73 kg)
Voltage & Power Rating
220 VAC, 50 Hz, 120 W
Duty Cycle
30 seconds ON, 3 minutes OFF
Altitude
2000m max
Humidity
40-80%
Temperature Range
100 - 300C
STEP 1
Assemble Table Frame to the Base
NOTE: The Table Bed arrives rotated into the fully inverted position. This
is the most convenient position from which to begin the
assembly process.
FIGURE 1
• Place the Base flat on the floor, with the holes up (Figure 1). The holes in the Base are off-center toward the front.
•Place the Table Frame upright on its legs on top of the Base, with the smaller, angled legs pointing in the same direction as the front of the Frame Base.
•Align the six (6) holes and insert a Bolt and Washer through each hole on both sides of the Base (Figure 2).
• Loosely tighten the Bolts until certain that all of the holes are aligned properly, then securely tighten with a 19 mm wrench.
FRONT
REAR
FIGURE 2
7
STEP 2
Assemble Main Shaft to the Table Frame
FIGURE 3
FIGURE 4
• With one of the Locking Knobs in hand, insert the Main Shaft into the Bed Frame Assembly (Figure 3).
• Install the main shaft in the Standard Setting by lining up the first set
of holes on the Main Shaft with the back of the Table Bed (Figure 3).
Short
Setting
Standard
Setting
Note: The Standard Setting on the Main Shaft will accommodate most
users. The second set of holes indicates the shorter height setting,
which may be used for users of smaller stature (Figure 3).
• Insert the Locking Knob and screw into one of the holes to hold the
Main Shaft in place (Figure 4).
• Insert and screw the second Locking Knob into the other hole.
Tighten the Locking Knob securely.
!
WARNING
FAILURE to properly secure the Locking Knobs could result in
serious injury or death!
STEP 3
Assemble Handles to Table Frame
FIGURE 5
8
• Hand tighten the Handles into the Handle Housings on each side of the Table Frame (Figure 5).
STEP 4
Connect to Power Source
• Connect to an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
FIGURE 6
• Rotate the upright using the Rotation Control Button. The
movement is indicated by the arrows (Figure 6).
9
Prepare to Invert
Before Using the Inversion Table
FIGURE 7
• Make sure the inversion table rotates smoothly to the fully inverted position and back by pushing the Rotation Control Button (Figure 7). Be sure to check that there is adequate clearance to rotate in front, above and behind you.
!
WARNING
FAILURE to engage the Ankle Lock System fully could result in
serious injury or death! ALWAYS wear securely tied, lace-up shoes
with a flat sole, such as a tennis shoe. DO NOT wear shoes with
thick soles, boots, high-tops or any shoe that extends above the
ankle bone, as this type of footwear could interfere with properly
securing your ankles. NEVER use the inversion table face down.
DO NOT attempt to invert before securing your ankles.
FIGURE 8
Securing Your Ankles
Prior to inverting, properly secure your ankles by following these steps:
1. With your back to the Table Bed, and using the handles to steady
yourself, carefully step onto the Base Platform to stand next to
one side of the Main Shaft (the Crossbar will be behind your
legs) (Figure 8). Lift the foot closest to the Main Shaft over the
Ankle Lock System and place it on the floor on the other side, to
straddle the Main Shaft.
2. If the Ankle Lock System is closed, grasp the Ankle Lock Handle
and push down, pull slightly closed, then push out to open it all
the way. Release the handle in the open position.
3. To balance yourself, rest only your lower body against the lower
portion of the Table Bed as you slide one ankle at a time from
the side (Figure 9) between the Front Foam Rollers & Rear Ankle
Cups, placing your feet on the Foot Platform.
FIGURE 9
Do not insert your foot into the Ankle Lock System as you would
slide your foot into a shoe (Figure 10). Your feet should always be
either on the floor or on the Foot Platform; never use any other
part of the inversion table as a step.
4. Press your ankles back firmly against the Rear Ankle Cups, then
slightly rotate the tops of the Cups so they are angled toward the
back of your leg/Achilles tendon. This will allow the Rear Cups to
rotate somewhat as you invert so the cushioned part comfortably
supports your ankles.
FIGURE 10
10
FIGURE 11
FIGURE 12
Prepare to Invert
Securing Your Ankles (continued)
FIGURE 13
5. Pull the Ankle Lock Handle towards your legs (Figure 13) and release when the Front Foam Rollers & Rear Ankle Cups fit snug, with a close fit against the smallest part of your ankles (Figure 14). Jiggle
the Ankle Lock Handle from front to back to make sure it has
fully engaged and is locked securely. Verify that no part of your footwear or garments touch or interfere with the Ankle Lock Ankle Lock System in any way during inversion.
Employ the method of “HEAR, FEEL, SEE, TEST” every time you secure
your ankles in the inversion table:
HEAR the locking Ankle Lock Handle click into place;
FEEL the Ankle Lock Handle to make sure it is fully engaged and
locked in its setting, and FEEL that the Front Foam Rollers & Rear
Ankle Cups are close-fitting around the smallest part of your ankles;
FIGURE 14
SEE that the EZ-Reach Handle is secure, and does not move out of
position, and SEE that there is NO space between your ankles and the
Foam Rollers/Ankle Cups.
TEST the Ankle Lock Ankle Lock System enclosure to ensure that it is
snug, close-fitting and secure by wiggling and attempting to pull your
feet through the Foam Rollers/Ankle Cups. Ensure that you CANNOT
disengage from the Ankle Cups each time before attempting to invert.
11
How to Invert
•Ensure there is clearance for the Table Bed to rotate without
contacting other objects or people.
FIGURE 15
• To begin inversion, push the Rotation Control Button in the direction
of your head. Release thebutton at the desired angle of inversion
(Figure 16).
•When first using the inversion table, DO NOT gointo full inversion
until you’re comfortable withinverting at 60º and able to reach the
RotationalControl Button from the inverted position. Seeback of the
Table Bed for illustrated stretches and exercises.
•Increase the duration of use over a period of time if desired. Listen to
your body. Inversion is NOT a no pain, no gain activity.
Full Inversion
FIGURE 16
• Inversion is defined as hanging completely upside down (90°) with your back free from the Table Bed. DO NOT attempt this step until you are comfortable with inverting to 60°.
FIGURE 17
• Press the Rotation Adjustment Button in the direction of your head and rotate completely upside down. Allow your back to relax and
hang freely from the Table Bed (Figure 17). In this position, you'll have
freedom of movement for stretching and exercise.
Returning Upright
•To return upright, press the Rotation Control Button in the direction
of your feet. Stop and rest for a few minutes just past horizontal (0°) to help prevent dizziness and allow your back to re-compress without discomfort before returning completely upright.
•Grasp the handle of the Ankle Lock System and press the button at
the top, pull slightly toward you, then push out to open it all the way
(Figure 18). Release the handle in the open position.
FIGURE 18
12
•Keep your lower body supported against the Table Bed as you step onto the floor. Carefully stand up and ensure you have your balance before stepping over the main shaft and finishing your dismount.
FULL 2 YEAR WARRANTY
The Teeter warranty set forth below and on Teeter’s website applies to US and Canadian customers only.
For international customers, please consult your local distributor for warranty information which will vary
depending on country.
During the period starting with the day of retail purchase and continuing for two (2) years, Teeter
extends to the owner a repair and replacement warranty against manufacturing defects in
FULL
W
AR
Y
2 YEAR
T
RA N
materials, workmanship, fabrics and padding. Teeter will repair or replace any such defect and will
pay the costs of all parts, labor and transportation. If a repair or replacement is not commercially
practical or cannot timely be made, then Teeter will, at the original Purchaser’s option, replace
with a comparable product or refund the purchase price.
Handling and transportation costs related to product warranty service only are covered by this warranty. This warranty does
not cover damage resulting from improper handling, assembly, or installation, repairs made by others, accident, misuse,
or abuse. Under no circumstances shall Teeter, or any other party involved in the sale of this product, have any liability for
incidental or consequential damage arising from breach of an express or implied warranty on any Teeter product.
EXCEPT AS SET FORTH ABOVE, NO WARRANTY IS GIVEN WITH RESPECT TO ANY TEETER PRODUCT, AND ALL EXPRESS
WARRANTIES ARE DISCLAIMED. This warranty shall be governed by the laws of the State of Washington, USA. To
the extent this warranty is found not to be enforceable, it shall be deemed revised to the extent necessary to make it
enforceable. This warranty and any controversy or claim arising out of this warranty or its interpretation shall be governed
by the laws of the State of Washington, USA. Any controversy or claim arising out of or relating to this warranty, its
interpretation, or any alleged breach thereof, which cannot be amicably settled between Teeter and the owner within
sixty (60) days of written notice by the aggrieved party to the other, shall be finally settled by arbitration submitted to
three (3) arbitrators selected from the panels of the arbitrators of the American Arbitration Association located closest to
Teeter’s principal place of business.
Some states do not allow the exclusion of incidental or consequential damage from a warranty, so the above limitation or
exclusion may not apply to you. Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may
vary from state to state. This warranty is completely transferable to any and all future owners of this product, provided no
alterations have been made to the product.
HOW TO SUBMIT YOUR REGISTRATION:
Step 1
Fill out this information for your own records.
Step 2
Go online to teeter.com to register your warranty.
Date of Purchase
Product & Model
Dealer Name
Serial No.
If you are unable to go online, you can request a warranty card to be mailed to you by calling Customer Service at 800-847-0143.
Please DO NOT mail this to Teeter.
PLEASE RETAIN THIS FOR YOUR RECORDS
13
Find These Great Products and More at teeter.com!
EP-970 Inversion Table
™
The EP-970 is the premier
home-use Teeter Inversion Table
featuring the Deluxe EZ-Reach
Handle to reduce the need for
bending, Traction Handles for added
stretching option, and Stretch Max
Handles for increased support.
P2 Traction Device
Apply gentle, user-controlled
traction to allow the lower back
to decompress, reduce nerve
pressure, and relax tense muscles.
reNEW Muscles Pain
Relieving Cream
™
T3 Massager
™
Countless options for self-massage,
trigger point therapy, and myofascial
release to resolve tension and pain
gently and naturally.
Deeply penetrates sore and aching
muscles on contact. Specially
formulated with emu oil, arnica,
MSM, and glucosamine.
Better Back Foam Roller
Neck Restore Tension Reliever
Durable, extra firm high-density
foam with versatile design for
posture, balance, self-massage,
and core exercises.
Provides support of the upper
neck/cervical spine for
self-administered suboccipital
release, a technique to reduce tension
in the supporting muscles.
™
If you have any trouble assembling the equipment, or questions
about its use, please contact customer service.
Roger Teeter
Founder & Innovator
USA: Teeter
9902 162nd St. Ct. E.
Puyallup, WA 98375
Toll Free: 800-847-0143
Fax: 800-847-0188
teeter.com | info@teeter.com
USA: 800-847-0143 or info@teeter.com
International: info@teeterintl.com
International: Teeter International, Ltd.
Gor-Ray House
758 Great Cambridge Rd
Enfield
Middlesex EN1 3GN
United Kingdom
teeterintl.com | info@teeterintl.com
EC
Any modification to this
device will void the TUV Listing.
REP
Medical Device Safety Service
GmbH
Schiffgraben 41
30175 Hannover
Germany
Tel. +49 511 62628630
U.S. and Foreign Patents Apply. Teeter and Teeter logo are registered trademarks of Teeter. Specifications subject to change without notice.
© COPYRIGHT 2016 Teeter. International Law Prohibits Any Copying. LP2240 0416-6
Class I, Type B
Medical Equipment
Download PDF
Similar pages
DVR N6 User Manual
copertina 4 finale.indd
HangUps Over EZ Owner's Manual
F9 English OM Tapered Bed.pmd
Keys Fitness IT-2 User's Manual
warning
null 9509987
owner`s manual - Energycenter.com
owner`s manual
Inversion Table