View MEASURING INSTRUMENTS Catalogue

Digital Anemometer
Application:
1. Air Velocity & Temperature Measurement
2. Max/Min/Average/Current reading
3. °C/°F temperature unit selection
4. Five units of air velocity: M/s, Km/h,ft/min,Knots,mph
5. Data hold
6. LCD backlight display
7. Manual/Auto power shut OFF
8. Beaufort Scale indication
9. Wind chill indication
10.Low battery indication
Air Velocity
Air Velocity
Unit
Range
0~45
M/s
0~8800
Ft/min
0~88
Knots
0~140
Km/hr
0~100
MPH
Temperature
Unit
°C
°F
Power Supply
Operating temperature/humidity
Store Temperature/ humidity
Packing Information
Dimension
Weight / Accessory
Air Velocity
Resolution
0.1
19
0.2
0.3
0.2
Air Velocity
Threshold
0.3
60
0.6
1
0.7
Range
Resolution
0°C~+45°C
0.2
32°F~113°F
0.36
9V Battery
-10°C~+50°C(14°F~122°F) / 40%RH~85%RH
-20°C~+60°C(-4°F~140°F) / 10%RH~90%RH
Air Velocity
Accuracy
±3 % ±0.1dgts
±3 % ±10dgts
±3 % ±0.1dgts
±3 % ±0.1dgts
±3 % ±0.1dgts
Accuracy
±2°C
±3.6°F
Main Unit : 145 X 72 X 35mm / Vane: 172 X 65 X29mm
276G (Including Battery) / Rubber Pouch
Axial Cooling Fan
Application: These fans are designed for force-air cooling of electronic devices.
The purpose of the AC fan as well as any other cooling fan, is to protect the
electronics devices in the system by keeping them at an optimal cooling temperature.
The fan will generate cool air by spinning at variable rate, thus protecting against
thermal variances that will undoubtedly harm the devices and will prevent
premature failure.
Optimum performance of your equipment is the fan’s first priority.
Motor Design
Housing
Impellor
Bearing
Operating Voltage
Dielectric Strength
Insulation & Resistance
Motor Protection
Weight
Size
:
:
:
:
:
:
:
:
:
:
Shade Pole
Aluminum Die-Cast
Thermoplastic
Sleeved or Ball
185-245V AC
AC 1500V for 1 Minute
Class B & Above 100M Ohms at 500VDC
Impedance Protected
480 grm
120 X 120 X 38 mm
You Can
Count
On Us
Digital Sound Level Meter
Infrared Termometer
Application :
This infrared thermometer is used for measuring the
temperature of the object's surface, which is applicable
for various hot, hazardous or hard-to reach objects without
contact safety and quickly.
This unit consists of optics, Temperature Sensor Signal
amplifier, Processing circuit and LCD Display. The Optics
collected the infrared energy emitted by object and focus
onto the Sensor. Then the sensor translates the energy
into an electricity signal. This signal will be turned out
to be digital shown on the LCD after the signal
amplifier and processing circuit.
: -50~550°C (-58~1022°F)
: 0~550°C (32~1022°F) : ± 1.5°C(±2.7°F)
or ±1.5%
-50~0°C (-58~32°F) : ±3°C (±5°F)
Whichever is greater
: 0.1°C or 0.1°F
Resolution
: 1% of reading or 1°C
repeatability
: 500 mSec, 95% response
Response Time
: 5-14 um
Spectral Response
: 0.10~1.00 Adjustable (0.95 Preset)
Emissivity
: 12:1
Distance to Spot Size
: 0~40°C (32~104°F)
Operating Temperature
: 10~95%RH non - condensing, up to 30°C (86°F)
Operating Humidity
: -20~60°C (-4~140°F)
Storage Temperature
: 3V (1.5V AAA Battery X2)
Power
Typical Battery Life (Alkaline) : Non - Laser Mode : 22hrs & Laser Mode : 12 hrs
Temperatures Range
Accuracy
Application: This equipment has been designed to meet the measurement
requirement of Safety Engineers, Health, Industrial Safety offices and Sound
Quality control in various environment, which include factory, office, traffic,
family and audio system.
This equipment has the following function:
1.It is designed according to the IEC651 TYPE2 & ANSI S1.4 TYPE2
2.Modern, compact, portable design
3.Accuracy up to : ± 1.5dB
4.Measurement rang: 30dBA-130dBA
5.MAX/MIN Hold
6.Auto backlight display
7.Auto power OFF
Measuring Range
Accuracy
Frequency Range
Frequency Weighting
Digital Display
Resolution
Sample Rate
Microphone
Power Supply
Power Life
Operating Condition
Storage Condition
Weight
Dimension
:
:
:
:
:
:
:
:
:
:
:
:
:
:
30dBA~130dBA
±1.5dB (94dB@1KHz)
31.5KHz~8KHz
A
4 digits
0.1dB
2 times/second
1/2 inch electret condenser microphone
9V Battery
about 30 hours (Alkaline Battery)
0~40°C, 10~80%RH
-10~60°C, 10~70%RH
144g (including battery)
57 X 26 X 149mm
Digital Lux Meter
Application: Widely used in electro-optical sources, research teaching,
metallurgy building, industry inspection as well as agriculture researching and
illumination control.
This equipment has the following function:
1.LUX/FC Unit selection function
2.Back light function
3.MAX/MIN measurements
4.Automatic measurements function
5.Date rise and fall time is short
6.Low battery indication
7.After 5 minutes Auto power OFF
: 0Lux~200, 000Lux/0Fc~185,806Fc
: ±3%rdg ±0.5%f.s. (<10,000Lux)
±4%rdg ±10%f.s. (>10,000Lux)
: 2 times /s
Digital Updates
: Silicon diode
Photometric Sensor
: 18 hours (continuous operation)
Battery life
Operating temperature and humidity : 0°C~40°C, 10%RH~90%RH
: -20°C~50°C, 10%RH~90%RH
Storage temperature and humidity
: 9V Battery
Power
: 52.5 X 52.5 X 166mm
Unit Size
: After 5 minutes
Auto Power Off
Measuring Range
Accuracy