ICE CREAM COUNTER TOP FREEZER
www.anvilworld.com
ALL ANVIL EQUIPMENT COMES WITH A
ONE YEAR WARRANTY ON COMPONENTS
AND DEFECTIVE WORKMANSHIP.
www.anvilworld.com
LIMITED WARRANTY
All equipment which is sold under ANVIL trademark and used for
commercial purposes is warranted against defects in materials and
workmanship. The warranty runs for one year from the date of
original installation and is for the benefit of the original purchaser
only. All other Warranties ,expressed or implied , statutory or
otherwise, including without limitations any implied Warranty of
Merchantability or fitness for purpose are excluded .The Seller shall
in no event be liable for direct,indirect or consequential damages in
connection with ANVIL commercial products.
The Sellers obligation under this Warranty is limited to the
repair of defects without charge. Defective units must be taken or
shipped,transportation charges prepaid,to ANVIL.
This Warranty is not effective if damage occurs because of
accident,carelessness,improper installation,lack of proper
set-up,supervision when required or if the equipment is installed or
operated in any manner contrary to the installation and
operating instructions. In these cases,repairs will be made at a
reasonable cost. Work performed by unauthorized personnel or
unauthorized service agencies using non Anvil spares voids this
Warranty.
NB:
REGISTER ON-LINE TODAY
Register your warranty on-line now at www.anvilworld.com
NO WEB ACCESS
If you do not have access to the Web. Kindly register by completing
the warranty registration form and fax it to the ANVIL office in the
country of purchase.
Failure to do so will invalidate your warranty.
4-INS-ICF1200
INSTALLATION OPERATION AND CARE OF
ICE CREAM COUNTER TOP FREEZER
MODEL: ICF1200
Page 1
UNPACKING
Unpack the product and check for any damage incurred during
transit. This should be reported to the responsible carrier, railway or
postal authority, and a request for a damage report should be made.
THESE INSTRUCTIONS
GUARANTEE OUR FULL
PROTECTING AGAINST
THE FORM FOR FILING
BY THE CARRIER.
MUST BE FOLLOWED FOR US TO
SUPPORT OF YOUR CLAIM FOR
LOSS FROM CONCEALED DAMAGE.
SUCH A CLAIM WILL BE PROVIDED
GENERAL INSTALLATION AND OPERATION INSTRUCTIONS:
The Anvil Countertop Display cabinets are designed for illuminated display of food
products at temperatures between -15°to -20° C. The cooling system ensures that
the products placed inside can be stored at the correct temperature.
1. The unit can be either placed on a suitable work surface or it can be fitted
into a countertop. Remember to install the unit in the most convenient
location for care of cleaning, maintenance and point of sale display.
2. IF THE UNIT HAS BEEN TRANSPORTED IN A NON-VERTICAL POSITION
ALLOW AT LEAST 1 HOUR FOR THE FOR THE OIL TO FLOW BACK
INTO THE COMPRESSOR AFTER FINAL INSTALLATION BEFORE
SWITCHING ON
3. Assemble the ice cream bin system and rear doors.
4. Remove all the protective film from exposed stainless steel parts and surfaces.
5. The unit is designed for food display. Clean carefully before using by
following the specific cleaning instructions detailed later in this manual.
6. Plug the unit into a suitable power source as detailed later in this manual.
7. The unit is provided with an illuminated main switch. Operation of this switch
turns on the unit and allows set up of the temperature.
8. Set the desired operating temperature on the digital controller. Specific
setting instructions are detailed later in this manual.
9. The interior lights can be operated by using the lighting button located on
the digital control.
Page 6
Page5
Page 2
790 (31.10”)
The following are the specific operating instructions to set the
temperature controller. It is advisable not to reset the controller
frequently.
Digital temperature
Display
519 (21,26”)
B
C
SPECIFIC OPERATING INSTRUCTIONS
Cooling indicator
Fan run indicator
TEMPERATURE CONTROL
Dimensions mm (inches)
1200mm (48”)
ICF1200
PRODUCT CODE
A
Demist indicator
Defrost indicator
On / Off push
button
Up and Down
push buttons
Defrost symbol
C
Demist symbol
Light switch
button
CONTROL PANEL
A
1. Press the
button for 3 seconds to switch on the controller.
2. To set the temperature, press
for 1 second. The numerals will flash on the
display. Adjust the temperature value up or down using the arrow buttons, the
value will be stored automatically after 6 seconds.
3. The unit will start cooling after 3 minutes. The range is effective to -20°C
4. The unit has a preset defrost cycle of every 6 hrs for a 20 minute duration.
5. Manual defrosting can be initiated by pressing the
arrow for 3 seconds.
The defrost symbol will illuminate on the digital display. The defrost mode can
be exited by pressing the
arrow for 3 seconds.
B
Page 3
6. Manual window demisting can be initiated by pressing the arrow for 3
seconds. the demist symbol will illuminate on the display.
The demist mode can be exited by pressing the
arrow for 3 seconds.
7. The lights may be switched on or off by the touch sensitive switch marked
8. To switch off the unit, press and hold the
button for 3 seconds.
Page 4
4. Do not use the unit in a dusty enviroment or in and explosive atmosphere.
5. This unit is designed for indoor use only
6. BASIC SAFETY RULES
a. Do not touch the unit when hands and feet are wet
b. Do not use the unit when bare foot
c. The unit should never be used by children or untrained personnel
d. Do not pull on the electrical cord when unplugging the machine.
CLEANING:
1) It is advisable to clean the interior of the machine as often as possible to
maintain good hygiene standards.
2) Always ensure that the unit is disconnected from the main power supply before
cleaning.
3) Do not use abrasive powders or solvents to clean this unit.
4) The unit should be cleaned with warm soapy water. Use only a damp cloth.
5) Dry the unit carefully with a cloth before turning back on.
6) IT IS ESSENTIAL THAT THE COOLING CONDENSOR IS CLEANED ON A
REGULAR BASIS TO ENSURE OPTIMUM PERFORMANCE OF THE UNIT.
THE CONDENSOR IS ACCESSIBLE BY REMOVING THE PANEL
ADJACENT TO THE CONTROLLER.
CLEAN CAREFULLY WITH A SUITABLE SOFT BRUSH OR COMPRESSED
AIR IF POSSIBLE.
THE UNIT SHOULD NEVER BE CLEANED USING A WATER JET OR SIMILAR
PRESSURE CLEANING DEVICE.
SAFETY:
1. The units are designed to operate on alternating current only (A.C.).
DO NOT CONNECT TO DIRECT CURRENT (D.C.).
2. Ensure that the power supply cord does not come into contact with hot
surfaces.
3. If the supply cord is damaged,it must be relaced with a new cord assembly
available from the suppliers agent.
DESCRIPTION OF MODELS
MODEL
ICF1200
DESCRIPTION
ICE CREAM DISPLAY
1200mm
CAPACITY
190L
VOLTAGE
( V/Hz)
230/50
POWER
( WATTS)
487