PoE Switch Web Managment Manual

Switch Web Management User Manual V2.0
Managed PoE Switch
Web Management User Manual
Version: V2.0
Date: 2015.8
1
Switch Web Management User Manual
Switch Web Management User Manual V2.0
TABLE OF CONTENTS
1. Introduction................................................................................................................................................................5
1.1 Overview..........................................................................................................................................................5
1.2 Web Management Login..............................................................................................................................5
1.3 Web-based User Interface............................................................................................................................6
1.4 Main Menu.......................................................................................................................................................6
2. Network Management..............................................................................................................................................7
2.1 IP Configuration........................................................................................................................................... 7
2.2 SNTP Configuration.......................................................................................................................................8
2.3 SNMP Configuration...................................................................................................................................... 8
2.3.1 SNMP System Configuration............................................................................................................ 9
2.3.2 SNMP Trap Configuration................................................................................................................. 9
2.4 System Log Configuration.......................................................................................................................... 10
3. Port Configure.........................................................................................................................................................10
3.1 Port Configuration ................................................................................................................................... 10
3.2 Link Aggregation.......................................................................................................................................... 11
3.2.1 Static Aggregation............................................................................................................................ 11
3.2.2 LACP Aggregation............................................................................................................................ 13
3.3 Port Mirroring................................................................................................................................................ 14
3.4 Thermal Protection Configuration..............................................................................................................15
4. PoE Configuration.................................................................................................................................................. 16
4.1 PoE Setting................................................................................................................................................... 16
4.2 PoE Status.................................................................................................................................................... 17
5. Advanced Configure.............................................................................................................................................. 18
5.1 VLAN.............................................................................................................................................................18
5.2 Port Isolation................................................................................................................................................. 21
5.2.1 Port Group..........................................................................................................................................21
5.2.2 Port Isolation......................................................................................................................................21
5.3 STP.................................................................................................................................................................22
5.3.1 STP Bridge Settings......................................................................................................................... 22
5.3.2 STP Bridge Port................................................................................................................................ 23
5.4 MAC Address Table.....................................................................................................................................24
2
Switch Web Management User Manual
Switch Web Management User Manual V2.0
5.5 IGMP Snooping............................................................................................................................................ 25
5.5.1 Basic Configuration.......................................................................................................................... 25
5.5.2 IGMP Snooping VLAN Configuration............................................................................................ 26
5.6 ERPS..............................................................................................................................................................27
5.7 LLDP.............................................................................................................................................................. 29
5.8 Loop Protection............................................................................................................................................ 30
6. QoS Configure........................................................................................................................................................ 30
6.1 QoS Port Classification............................................................................................................................... 31
6.2 Port Policing.................................................................................................................................................. 32
6.3 Storm Control Configuration.......................................................................................................................32
7. Security Configure..................................................................................................................................................33
7.1 Password.......................................................................................................................................................33
7.2 802.1X............................................................................................................................................................33
7.3 DHCP Snooping........................................................................................................................................... 35
7.3.1 DHCP Overview................................................................................................................................ 35
7.3.2 About DHCP Snooping.................................................................................................................... 35
7.3.3 DHCP Snooping Configure............................................................................................................. 36
7.4 IP&MAC Source Guard............................................................................................................................... 37
7.4.1 Port Configuration.............................................................................................................................37
7.4.2 Static Table........................................................................................................................................ 38
7.5 ARP Inspection.............................................................................................................................................38
7.5.1 Port Configuration.............................................................................................................................39
7.5.2 VLAN Configuration..........................................................................................................................40
7.5.3 Static Table........................................................................................................................................ 41
7.6 ACL.................................................................................................................................................................41
7.6.1 ACL Ports Configure........................................................................................................................ 42
7.6.2 Rate Limiter Configuration...............................................................................................................43
7.6.3 Access Control List Configuration.................................................................................................. 43
8. Diagnostics.............................................................................................................................................................. 44
8.1 Ping Test........................................................................................................................................................44
8.2 Cable Diagnostics........................................................................................................................................ 45
8.3 CPU Load...................................................................................................................................................... 45
9. Maintenance............................................................................................................................................................46
3
Switch Web Management User Manual
Switch Web Management User Manual V2.0
9.1 Restart Device.............................................................................................................................................. 46
9.2 Factory Defaults........................................................................................................................................... 46
9.3 Firmware Upgrade....................................................................................................................................... 47
9.4 Firmware Select............................................................................................................................................47
9.5 Firmware Select............................................................................................................................................48
9.5.1 Download Configuration File...........................................................................................................48
9.5.2 Upload Configuration File................................................................................................................ 48
9.5.3 Activate Configuration...................................................................................................................... 49
9.5.4 Delete Configuration File................................................................................................................. 49
4
Switch Web Management User Manual
Switch Web Management User Manual V2.0
1. Introduction
1.1 Overview
Thank you for purchasing our managed switch series, whose all software function can be managed,
configured and monitored via embedded Web-based(HTML) interface. By a standard browser, you can
manage switch at any remote site in the network. Browser as a universal access tool, uses the HTTP protocol
to communicate with switch directly.
1.2 Web Management Login
Open installed web browser on your PC, input the switch’s IP address like http://xxx.xxx.xxx.xxx, then open
that URL to login web management.
Note: IP address of switch is 192.168.2.1 by default. So please input http://192.168.2.1 in browser.
When the login window appears, please enter the default username "admin" with password "system" . Then
click OK to login.
Figure1-1 Login Window
Default User Name: admin
Default Password: system
5
Switch Web Management User Manual
Switch Web Management User Manual V2.0
1.3 Web-based User Interface
After entering the username and password, the main screen appears as following Figure1-2.
Figure1-2 Web management Main Page interface
This Main Page interface includes mainly 3 parts. Here is description:
Part
Description
Part 1
Company LOGO; Panel display; Port indicators, including PoE and Link working status;
Language selection button; Help document
Part 2
The Main Menu, lets you access all the commands and statistics
Part 3
Main Screen, showing configuration details
The Web agent displays an image of the Managed Switch’s ports. Different colors mean different states, they
are illustrated as follows:
: 100Mbps linked ;
: 1000Mbps linked ;
: No link
1.4 Main Menu
Using the onboard Web agent, you can define system parameters, manage and control the Managed Switch,
and all its ports, or monitor network conditions. Via the Web-Management, the administrator can set up the
Managed Switch by selecting the functions those listed in the Main Menu. Following is short description:
Information & Status - Users can check switch information and working status under this menu.
Network Admin - Users can check and configure related features of network under this menu.
Port Configure - Users can check and configure specification of ports under this menu.
PoE - Users can check and configure related features of Power-over-Ethernet (PoE) under this
menu.
Advanced Configure - Users can check and configure L2 advanced features under this menu.
Security Configure - Users can check and configure security features of the switch under this
menu.
Qos Configure - Users can check and configure Qos features of the switch under this menu.
Diagnostics - Users can check and configure Diagnostics features of the switch under this menu.
6
Switch Web Management User Manual
Switch Web Management User Manual V2.0
2. Network Management
2.1 IP Configuration
Note:IP address of switch is 192.168.2.1 by default, and the default subnet mask is 255.255.255.0(24)
Click "Network Admin" > ''IP'', screen will shows as:
Figure 2-1 IP Configuration Screen
Following is description detail about IP configuration:
Name
Port Name
VLAN
Description
Display system’s port name
VLAN for for access and management of switch
-
IPv4 DHCP
IPv4
-
If enable, it means that VLAN port start IPv4 DHCP client, to dynamically get
IPv4 addresses of the switch. Otherwise, it will use switch’s static IP
configuration.
Fallback(Seconds), means the waiting time for switch to get dynamic IP
address via DHCP. The value of "0" here means never over the time.
Current Lease, means the IP address get from DHCP
-
Address: static IPv4 address entered by user.
Mask Length: static IPv4 subnet mask entered by user.
-
Click ''Add Interface''to create a new management for VLAN and IP address. Click ''Save''to save settings.
Note: The switch only created VLAN1 by default. If user needs to use other VLAN for switch
management, please first add VLAN in the VLAN module, and add the relevant port to the VLAN.
7
Switch Web Management User Manual
Switch Web Management User Manual V2.0
2.2 SNTP Configuration
SNTP is an acronym for Simple Network Time Protocol, a network protocol for synchronizing the clocks of
computer systems. You can specify SNTP Servers and set GMT Time zone. The SNTP Configuration screens
will appear after you click "Network Admin" > "SNTP".
Figure 2-2 SNTP Setting Screen
Configuration object and description is:
Object
Description
Click drop-down menu to select "Enabled" or "Disabled" SNTP.
Mode
SNTP Sever
Enabled: Enable SNTP mode operation. When enabling SNTP mode operation, the
agent forwards and transfers SNTP messages between the clients and the server
when they are not on the same subnet domain.
Disabled: Disable SNTP mode operation.
After input SNTP server IP address, SNTP information will be get from that server.
After configuration was set, please click "Save" to save the setting.
2.3 SNMP Configuration
Simple Network Management Protocol (SNMP) is an application layer protocol that facilitates the exchange of
management information between network devices. It is part of the Transmission Control Protocol/Internet
Protocol (TCP/IP)protocol suite. SNMP enables network administrators to manage network performance, find
and solve network problems, and plan for network growth.
This switch support SNMPv1, v2c. Different versions of SNMP provides different security level for management
stations and network devices.
In SNMP’s v1 and v2c, it uses the "Community String" for user authentication. That string is similar to
password function. SNMP application of remote user and SNMP of the Switch must use the same community
string. SNMP packets of any unauthorized sites will be ignored (discarded).
"Community String" by default for switch’s SNMPv1 and v2c access management is:
1.
2.
– allow authentication management station to read MIB objects.
– allow authentication management station to read, write and edit MIB objects.
Trap
Used by the agent to asynchronously inform the NMS of some event. These events may be very serious, such
as reboot (someone accidentally turned off switch), or just general information, such as port status change. In
8
Switch Web Management User Manual
Switch Web Management User Manual V2.0
these cases, switch create trap information and send then to receiver or network admin. Typical trap includes
authentication failure, networking changes and cold/hot start trap.
MIB
A MIB is a collection of managed objects residing in a virtual information store. Collections of related managed
objects are defined in specific MIB modules. Switch uses standard MIB-II information management module.
So, MIB object value can be read by any SNMP web-managed software.
2.3.1 SNMP System Configuration
You can enable or disable the SNMP System Configuration. Its screen will appear after you click "Network
Admin" > "SNMP" > "System"
Figure 2-3 SNMP System Setting Screen
Configuration object and description is:
Object
Description
Mode
Enabled or Disable SNMP function
Version
Click drop-down menu to select SNMP v2c or SNMP v1 version
Read Community
Public: allow authentication management station to read MIB objects
Write Community
Private: allow authentication management station to read and write MIB objects.
2.3.2 SNMP Trap Configuration
User can enable or disable SNMP Trap function and set configuration. Click "Network Admin" > "SNMP" >
"Trap" , then this screen will show as:
9
Switch Web Management User Manual
Switch Web Management User Manual V2.0
2.4 System Log Configuration
User can configure switch’s system log, via following screen after click "Network Admin" > "Syslog"
Figure 2-4 System Log Configuration Screen
Configuration object and description is:
Object
Description
Server Mode
Enabled or Disable SNMP System Log function. If ''Enable''is selected, switch will send
System Log to defined server.
Server Address
Syslog Level
Defined server IP address
To define leverl of System Log, including:
Info: Information, warnings and errors.
Warning: warnings and errors.
Error: errors.
3. Port Configure
3.1 Port Configuration
This page is for configuring port specifications of switch. After click "Port Configure" > "Ports", this screen will
appear as:
Figure 3-1 Port Configure Screen
10
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Configuration object and description is:
Object
Link
Description
Red color means Link Down, green color means Link Up
Speed
Select the port speed and full / half duplex mode.
"Disabled" means that port is disabled.
"Auto" meaning in full-duplex (FDX) or half-duplex mode (HDX) (1000mbps always in
full-duplex mode) auto negotiate among 10,100,1000Mbps devices. "Auto" setting
allows the port to automatically determine the fastest settings for the device
connected, and to apply these settings.
"1000-X_AMS" means that port is Ethernet/Optical combo port, and optical port is
prioritized.
Other options are 10M HDX, 10M FDX, 100M HDX, 100M FDX, 1000M FDX, 1000-X.
Flow Control
It is a flow control mechanism for a variety of port configurations. Full-duplex ports
use 802.3x flow control, half-duplex ports use backpressure flow control. It is disabled
by default.
Check to enable flow control.
Maximum Frame
Size
It is used to set the maximum frame size for Ethernet. The default setting is 9600,
which is to support Jumbo frames.
Click "Save" to store and active settings.
3.2 Link Aggregation
Users can set up multiple links among multiple switches. Link Aggregation, is a method that tie some physical
ports together as one logic port, to enlarge bandwidth. This switch supports up to 13 groups Link Aggregation,
2 to 8 port as one group.
Note: If any port in the link aggregation group is disconnected, data packet that sent to disconnected
port will share load with other connected port in this aggregation group.
3.2.1 Static Aggregation
In this page, user can configure static aggregation of switch’s ports. After click the menu "Port Configure" >
"Aggregation" > "Static", followed window will appear for making static aggregation settings.
11
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Figure 3-2 Port Static Aggregation Configuration Screen
Configuration object and description is:
Object
Description
Aggregation
Mode
This parameter is flow hash algorithm among LAG(Link Aggregated Group) ports.
Configuration
Group ID
Port Members
Static aggregation group ID
This switch supports up to 13 groups Link Aggregation, 2 to 8 port as one group.
Click "Save" to store and active settings.
Note: It allows a maximum of 8 ports to be aggregated as 1 static trunk group at the same time.
12
Switch Web Management User Manual
Switch Web Management User Manual V2.0
3.2.2 LACP Aggregation
Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between
Partner Systems that require high-speed redundant links. Link aggregation lets you group up to eight
consecutive ports into a single dedicated connection. This feature can expand bandwidth to a device on the
network. LACP operation requires full-duplex mode. For more detailed information, refer to the IEEE 802.3ad
standard.
Users can create dynamic aggregation group for switches. After click "Port Configure" > "Aggregation" >
"LACP", users can set LACP configuration in followed screen.
Figure 3-3 LACP Configuration Screen
Configuration object and description is:
Object
LACP
Key
Description
Enable or disable LACP function of that port.
The Key value incurred by the port, range 1-65535 . The Auto setting will set the key
as appropriate by the physical link speed, 10Mb = 1, 100Mb = 2, 1Gb = 3. Using the
Specific setting, a user-defined value can be entered. Ports with the same Key value
can participate in the same aggregation group, while ports with different keys cannot.
Role
The Role shows the LACP activity status. The Active will transmit LACP packets each
second, while Passive will wait for a LACP packet from a partner (speak if spoken to).
Timeout
The Timeout controls the period between BPDU transmissions. Fast will transmit
LACP packets each second, while Slow will wait for 30 seconds before sending a
LACP packet.
Prio
The Prio controls the priority of the port. If the LACP partner wants to form a larger
group than is supported by this device then this parameter will control which ports will
be active and which ports will be in a backup role. Lower number means greater
priority.
Click "Save" to store and active settings.
13
Switch Web Management User Manual
Switch Web Management User Manual V2.0
3.3 Port Mirroring
Configure port Mirroring on this page. This function provides monitoring of network traffic that forwards a copy
of each incoming or outgoing packet from one port of a network switch to another port where the packet can be
studied. It enables the manager to keep close track of switch performance and alter it if necessary.
To configure Mirror settings, please click "Port Configure" > "Mirroring" . Then followed screen will appear as:
Figure 3-4 Mirror Configuration Screen
Configuration object and description is:
Object
Description
Port mirror to
Frames from ports that have either source (rx) or destination (tx) mirroring enabled
are mirrored on this port. Disabled disables mirroring.
Select source port mirror mode.
Rx only Frames received on this port are mirrored on the mirror port. Frames
transmitted are not mirrored.
Tx only Frames transmitted on this port are mirrored on the mirror port. Frames
received are not mirrored.
Mode
Disabled Neither frames transmitted nor frames received are mirrored.
Enabled Frames received and frames transmitted are mirrored on the mirror port.
Note: For a given port, a frame is only transmitted once. It is therefore not possible
to mirror mirror port Tx frames. Because of this, mode for the selected mirror port
is limited to Disabled or Rx only.
Click "Save" to store and active settings.
Note: You can not set fast speed port(s) mirror to a low speed port. For example, there is problem if
you try to mirror 100Mbps port(s) to a 10 Mbps port. So destination port should has equal or higher speed
comparing to source port. Besides, source port and destination port should not be same one.
14
Switch Web Management User Manual
Switch Web Management User Manual V2.0
3.4 Thermal Protection Configuration
Thermal protection is for detecting and protecting working switch. When switch detected port temperature is
higher that defined temperature, system will disable the port, to protect switch itself.
After click "Port Configure" > "Thermal Protection", followed screen will appear as:
Figure 3-5 Thermal Protection Configuration Screen
Configuration object and description is:
Object
Description
Temperature settings for This switch support 4 Thermal Protection priority groups, and each of them can
priority groups
have a defined temperature for protection.
Port priorities
Define which priority group that port belong to.
Click "Save" to store and active settings.
Note: By default, all ports of switch are belong to Priority Group 0, with protected temperature 225
degree C.
15
Switch Web Management User Manual
Switch Web Management User Manual V2.0
4. PoE Configuration
Power-over-Ethernet (PoE), means Ethernet network power supply via 100BASE-TX, 1000BASE-T. Its
maximum power distance is 100 meters. By PoE power system, based on Ethernet wiring network of UTP
Cat5 or higher Cable, it can give power to IP camera, VoIP phone, wireless AP, as well as transmit data. So
there is no need to concern about the power wire building, reducing the cost of networking building.
PoE power supply system has unified standard, IEEE 802.3af and 802.3at. So devices from different
manufacturers have no problem in general usage, as long as they are complied with these standards.
PD, it is defined as powered device in the PoE Power Supply System , primarily including IP camera, wireless
AP, network VoIP phone, and other IP-based terminal equipment.
The whole process of PoE:
1. Detection: At beginning, PSE device output a very small voltage, to detect and judge if its linked PD is
IEEE802.3af / IEEE802.3at compliant device. Only if detected that PD is a standard compliant device, then it
will go to next step.
2. PD Classification: After detected PDs, PSE will classify them and recognize what is the power that PD
required.
3. Power up: When above 2 steps finished, PSE start feeding required power for PD, with 44~57VDC output
voltage.
4. Power supply: PSE provides stable 44~57V DC to PDs, and auto feeding power as requirement of PDs.
Maximum power of single PoE port for IEEE 802.3af devices: 15.4W; Maximum power of single PoE port for
IEEE 802.3at devices: 25.5W.
5. Disconnection: If PD is disconnected or user disable PoE from management software, PSE will quickly(300400ms) stop powering PD.
In any moment of PSE powering PD process, PSE will stop working and then restart from step1 if abnormal
situation happens, such as PD Short circuit, power consumption is higher than feeding power, and so on.
4.1 PoE Setting
After click "PoE"> "PoE Setting", user can make PoE settings in followed screen:
Figure 4-1 PoE Setting Screen
16
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Configuration object and description is:
Object
Description
Reserved Power
determined by
This switch supports 2 modes for reserved power determination.
Auto: Switch automatically assigned maximum power of switch port
according to detected PD class. About PD Class, please refer to the 802.3af /
802.3at definition.
Manual: Maximum reserved power of the port is customize by the user.
Power Management Mode
This switch supports 2 modes for Power Management.
1. Actual Consumption: In this mode, when the actual power consumption of
all the ports exceeds the switch’s power budget, the lowest priority port will
be shut down. If all ports have the same priority, then the maximum port
number would be shut down.
2. Reserved Power: In this mode, when the reserved power consumption of
all the ports exceeds the switch’s power budget, the port that connect to new
PD will not be enabled.
Primary Power Supply [W]
Users can set the maximum primary power of the whole switch. Default
setting is 370W.
PoE Mode
This switch support 802.3af(PoE) and 802.3at(PoE+) mode. Default setting
is 802.3at.
Priority
Define the priority of the PoE port. Priority from low to high is Low, High,
Critical.
Maximum Power(W)
It is for define port’s maximum Power when user set Manual as reserved
power determination mode.
Click "Save" to store and active settings.
4.2 PoE Status
In this page, user can check and look PoE status of all ports, after click "PoE"> "PoE Status".
Figure 4-2 PoE Status Screen
17
Switch Web Management User Manual
Switch Web Management User Manual V2.0
5. Advanced Configure
5.1 VLAN
VLAN(Virtual Local Area Network) logically divide one LAN(Local Area Network) into a plurality of subsets, and
each subset will form their own broadcast area network. In short, VLAN is a communication technology that
logically divide one physical LAN into multiple broadcast area network (multiple VLAN). Hosts within a VLAN can
communicate directly. But VLAN groups can not directly communicate with each other. So it will limit the
broadcast packets within a VLAN. Since it can not directly access between VLAN groups, thus it improves
network security.
Click "Advanced Configure"> "VLANs" to see 802.1Q VLAN configuration screen as following:
Figure 5-1 802.1Q VLAN Configuration Screen
Configuration object and description is:
Object
Description
Allowed VLANs
Here displays created VLAN ID. It is 1 by default. If you want to create new VLAN, just
need to add VLAN ID here.
Ethertype for
Custom S-ports
This field specifies the ethertype/TPID (specified in hexadecimal) used for Custom Sports. The setting is in force for all ports whose Port Type is set to S-Custom-Port.
The port mode (default is Access) determines the fundamental behavior of the port in
question. A port can be in one of three modes as described below.
Whenever a particular mode is selected, the remaining fields in that row will be either
grayed out or made changeable depending on the mode in question.
Grayed out fields show the value that the port will get when the mode is applied.
Mode
Access:
Access ports are normally used to connect to end stations. Access ports have the
following characteristics:


18
Member of exactly one VLAN, the Port VLAN (a.k.a. Access VLAN), which by
default is 1
Accepts untagged and C-tagged frames
Switch Web Management User Manual
Switch Web Management User Manual V2.0


Discards all frames that are not classified to the Access VLAN
On egress all frames classified to the Access VLAN are transmitted untagged.
Other (dynamically added VLANs) are transmitted tagged
Trunk:
Trunk ports can carry traffic on multiple VLANs simultaneously, and are normally used to
connect to other switches. Trunk ports have the following characteristics:





By default, a trunk port is member of all VLANs (1-4094)
The VLANs that a trunk port is member of may be limited by the use of Allowed
VLANs
Frames classified to a VLAN that the port is not a member of are discarded
By default, all frames but frames classified to the Port VLAN (a.k.a. Native
VLAN) get tagged on egress. Frames classified to the Port VLAN do not get Ctagged on egress
Egress tagging can be changed to tag all frames, in which case only tagged
frames are accepted on ingress
Hybrid:
Hybrid ports resemble trunk ports in many ways, but adds additional port configuration
features. In addition to the characteristics described for trunk ports, hybrid ports have
these abilities:



Port VLAN
Can be configured to be VLAN tag unaware, C-tag aware, S-tag aware, or Scustom-tag aware
Ingress filtering can be controlled
Ingress acceptance of frames and configuration of egress tagging can be
configured independently
Determines the port's VLAN ID (a.k.a. PVID). Allowed VLANs are in the range 1 through
4094, default being 1.
On ingress, frames get classified to the Port VLAN if the port is configured as VLAN
unaware, the frame is untagged, or VLAN awareness is enabled on the port, but the
frame is priority tagged (VLAN ID = 0).
On egress, frames classified to the Port VLAN do not get tagged if Egress Tagging
configuration is set to untag Port VLAN.
The Port VLAN is called an "Access VLAN" for ports in Access mode and Native VLAN
for ports in Trunk or Hybrid mode.
Ports in hybrid mode allow for changing the port type, that is, whether a frame's VLAN tag
is used to classify the frame on ingress to a particular VLAN, and if so, which TPID it
reacts on. Likewise, on egress, the Port Type determines the TPID of the tag, if a tag is
required.
Unaware:
On ingress, all frames, whether carrying a VLAN tag or not, get classified to the Port
VLAN, and possible tags are not removed on egress.
Port Type
C-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 get classified to the VLAN ID
embedded in the tag. If a frame is untagged or priority tagged, the frame gets classified to
the Port VLAN. If frames must be tagged on egress, they will be tagged with a C-tag.
S-Port:
On ingress, frames with a VLAN tag with TPID = 0x8100 or 0x88A8 get classified to the
VLAN ID embedded in the tag. If a frame is untagged or priority tagged, the frame gets
classified to the Port VLAN. If frames must be tagged on egress, they will be tagged with
an S-tag.
19
Switch Web Management User Manual
Switch Web Management User Manual V2.0
S-Custom-Port:
On ingress, frames with a VLAN tag with a TPID = 0x8100 or equal to the Ethertype
configured for Custom-S ports get classified to the VLAN ID embedded in the tag. If a
frame is untagged or priority tagged, the frame gets classified to the Port VLAN. If frames
must be tagged on egress, they will be tagged with the custom S-tag.
Ingress Filter
Hybrid ports allow for changing ingress filtering. Access and Trunk ports always have
ingress filtering enabled.
If ingress filtering is enabled (checkbox is checked), frames classified to a VLAN that the
port is not a member of get discarded.
If ingress filtering is disabled, frames classified to a VLAN that the port is not a member of
are accepted and forwarded to the switch engine. However, the port will never transmit
frames classified to VLANs that it is not a member of.。
Hybrid ports allow for changing the type of frames that are accepted on ingress.
Tagged and Untagged
Both tagged and untagged frames are accepted.
Ingress
Acceptance
Tagged Only
Only tagged frames are accepted on ingress. Untagged frames are discarded.
Untagged Only
Only untagged frames are accepted on ingress. Tagged frames are discarded.
Ports in Trunk and Hybrid mode may control the tagging of frames on egress.
Untag Port VLAN
Frames classified to the Port VLAN are transmitted untagged. Other frames are
transmitted with the relevant tag.
Egress
Tagging
Tag All
All frames, whether classified to the Port VLAN or not, are transmitted with a tag.
Untag All
All frames, whether classified to the Port VLAN or not, are transmitted without a tag.
This option is only available for ports in Hybrid mode.
Allowed VLANs
Ports in Trunk and Hybrid mode may control which VLANs they are allowed to become
members of. Access ports can only be member of one VLAN, the Access VLAN.
The field's syntax is identical to the syntax used in the Enabled VLANs field. By default, a
Trunk or Hybrid port will become member of all VLANs, and is therefore set to 1-4094.
The field may be left empty, which means that the port will not become member of any
VLANs.
Forbidden
VLANs
A port may be configured to never be member of one or more VLANs. This is particularly
useful when dynamic VLAN protocols like MVRP and GVRP must be prevented from
dynamically adding ports to VLANs.
The trick is to mark such VLANs as forbidden on the port in question. The syntax is
identical to the syntax used in the Enabled VLANs field.
By default, the field is left blank, which means that the port may become a member of all
possible VLANs.
Click "Save" to store and active settings.
20
Switch Web Management User Manual
Switch Web Management User Manual V2.0
5.2 Port Isolation
Port isolation is for limiting data between ports. It is similar to VLAN, but more stricter.
5.2.1 Port Group
This switch support port groups. Members of port group can forward date.
Note: port can belong to to multiple port groups. Data can be forwarded among any port that belong to
one port group.
After Click "Advanced Configure" > "Port Isolation" > "Port Group", then followed screen will appear for making
port group configuration.
Figure 5-2 Port Group Configuration Screen
Configuration object and description is:
Object
Port Members
Description
Check the corresponding box to set them as one port group.
Click "Add New Port Group" to create a new port group, "Delete" to remove corresponding port group, and
"Save" to store and active settings.
5.2.2 Port Isolation
After Click "Advanced Configure" > "Port Isolation" > "Port Isolation", then followed screen will appear for making
port isolation configuration.
21
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Figure 5-3 Port Isolation Configuration Screen
Configuration object and description is:
Object
Port Number
Description
Check box to set corresponding port as port isolation, so that they can not forward data flow.
Click "Save" to store and active settings.
5.3 STP
The Spanning Tree Protocol (STP) can be used to detect and disable network loops, and to provide backup links
between switches, bridges or routers. This allows the switch to interact with other bridging devices in your
network to ensure that only one route exists between any two stations on the network, and provide backup links
which automatically take over when a primary link goes down.
5.3.1 STP Bridge Settings
This page allows you to configure port STP settings. After Click "Advanced Configure" > "Spanning Tree" >
"Bridge Settings" , followed screen will appear.
Figure 5-4 Spanning Tree Configuration Screen
Configuration object and description is:
22
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Object
Protocol Version
Bridge Priority
Forward Delay (4-30)
Description
Click drop-down menu to select STP protocol version, including:
STP - Spanning Tree Protocol (IEEE802.1D);
RSTP - Rapid Spanning Tree Protocol (IEEE802.1w)
Controls the bridge priority. Lower numeric values have better priority. The bridge
priority plus the MSTI instance number, concatenated with the 6-byte MAC address of
the switch forms a Bridge Identifier.
Forward Delay setting range is from 4 to 30 seconds. Default value is 15 seconds.
Max Age (6-40)
The maximum age of the information transmitted by the Bridge when it is the Root
Bridge. Valid values are in the range 6 to 40 seconds. Default value is 20 .
Maximum Hop Count
(6-40)
This defines the initial value of remaining Hops for MSTI information generated at the
boundary of an MSTI region. It defines how many bridges a root bridge can distribute
its BPDU information. Valid values are in the range 6 to 40 hops.
The number of BPDU's a bridge port can send per second. When exceeded,
Transmit Hold Count (1transmission of the next BPDU will be delayed. Valid values are in the range 1 to 10
10)
BPDU's per second. Default value is 6 .
Click "Save" to store and active settings.
5.3.2 STP Bridge Port
After Click "Advanced Configure" > "Spanning Tree" > "Bridge Ports" , followed screen will appear.
Figure 5-5 STP Configuration Screen
Configuration object and description is:
Object
STP Enabled
Path Cost(0=Auto)
23
Description
Check to enable STP function.
Controls the path cost incurred by the port. The Auto setting will set the path cost as
appropriate by the physical link speed, using the 802.1D recommended values. Using
Switch Web Management User Manual
Switch Web Management User Manual V2.0
the Specific setting, a user-defined value can be entered. The path cost is used when
establishing the active topology of the network. Lower path cost ports are chosen as
forwarding ports in favour of higher path cost ports. Valid values are in the range 1 to
200000000.
Priority
Auto Edge
Controls the port priority. This can be used to control priority of ports having identical
port cost. (See above).
Check box to set corresponding port as Auto Edge.
Restricted Role
Check box to set corresponding port as Restricted Role
Restricted TCN
Check box to set corresponding port as Restricted TCN
BPDU Guide
Check box to enable BPDU Guide. So when port receives BPDU reception, it will turn to
Disable(Shut Down) status.
Point-to-point
Controls whether the port connects to a point-to-point LAN rather than a shared
medium. This can be automatically determined, or forced either true or false. Transition
to the forwarding state is faster for point-to-point LANs than for shared media. (This
applies to physical ports only. Aggregations are always forced Point2Point.
Click "Save" to store and active settings.
5.4 MAC Address Table
This page allows you to configure Mac address table settings. After Click "Advanced Configure" > "Mac Table" ,
followed screen will appear.
Figure 5-6 MAC Address Table Configuration Screen
Configuration object and description is:
24
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Object
Disable
Automatic Aging
Description
If the box is checked, then the automatic aging function is disabled.
Aging Time
The time after which a learned entry is discarded .
Range: 10-1000000 seconds;
Default: 300 seconds.
MAC Table
Learning
This switch supports 3 types for MAC Table Learning
1. Auto: port will auto learn Mac address.
2. Disable: port will NOT learn MAC address.
3. Secure: port only forward data of configured static MAC address.
Static MAC Table
Configuration
The static entries in the MAC table are shown in this table. Click "Add New Static Entry"
to create a new record.
Click "Save" to store and active settings.
5.5 IGMP Snooping
Internet Group Management Protocol (IGMP) lets host and routers share information about multicast groups
memberships. IGMP snooping is a switch feature that monitors the exchange of IGMP messages and copies
them to the CPU for feature processing. The overall purpose of IGMP Snooping is to limit the forwarding of
multicast frames to only ports that are a member of the multicast group.
5.5.1 Basic Configuration
After Click "Advanced Configure" > "IGMP Snooping" > "Basic Configuration", followed screen will appear.
Figure 5-7 IGMP Snooping Basic Configuration
Configuration object and description is:
25
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Object
Snooping Enabled
Unregistered IPMCv4
Flooding Enabled
Description
Enable or disable the IGMP snooping. The default value is "Disabled".
Enable: check the box; Disable: do not check the box.
Check the box to enable unregistered IPMCv4 Flooding
Router Port
Specify which ports act as router ports. A router port is a port on the Ethernet
switch that leads towards the Layer 3 multicast device or IGMP querier.
If an aggregation member port is selected as a router port, the whole aggregation
will act as a router port.
Fast Leave
Fast leave performs deleting MAC forward entry immediately upon receiving
message for group de-registration
Click "Save" to store and active settings.
5.5.2 IGMP Snooping VLAN Configuration
After Click "Advanced Configure" > "IGMP Snooping" > "VLAN Configuration", followed screen will appear.
Figure 5-7 IGMP Snooping VLAN Configuration
Configuration object and description is:
Object
Description
Snooping Enabled
Enable the per-VLAN IGMP Snooping. Up to 32 VLANs can be selected for IGMP
Snooping.
Querier Election
Enable to join IGMP Querier election in the VLAN. Disable to act as an IGMP
Non-Querier.
Querier Address
Define the IPv4 address as source address used in IP header for IGMP Querier
election. When the Querier address is not set, system uses IPv4 management
address of the IP interface associated with this VLAN. When the IPv4
management address is not set, system uses the first available IPv4
management address. Otherwise, system uses a pre-defined value. By default,
this value will be 192.0.2.1.
Click "Save" to store and active settings.
26
Switch Web Management User Manual
Switch Web Management User Manual V2.0
5.6 ERPS
ERPS(Ethernet Ring Protection Switching), it integrates OAM function and APS protocol. If the ring network was
interrupted accidentally, the fault recovery times could be less than 50ms to quickly bring the network back to
normal operation. ITU-T G.8032 is the first industry standard for ERPS.
Note: Before enable ERPS, STP of ring port should be disabled. .
After Click "Advanced Configure" > "ERPS " , followed screen will appear.
Figure 5-8 EPRS Configuration
Configuration object and description is:
Object
Ring ID
Description
ERPS Ring ID
East Port
Number of the port which participate in this Ring protection.
West Port
Number of the other port which participate in this Ring protection.
Ring Type
Available selection: ''Major Ring'' or ''Sub Ring''.
Only in case of Multi Ring application, ''Sub Ring'' is required to configure.
Default Ring Type: ''Major Ring''. Only if there is multi ring application, it is required
to set.
Interconnected Node
In Multi Ring application, Interconnected Node is the node that connect 2 or more
rings.
Major Ring ID
In Single Ring application, Major Ring ID is same as Ring ID.
In Multi Ring application, Sub Ring has to be type as Major Ring ID.
R-APS VLAN(1-4094) Define VLAN for R - APS VLAN .
Click "Add New Ring Group" to create a new ERPS ring application.
Click "Save" to store and active settings.
27
Switch Web Management User Manual
Switch Web Management User Manual V2.0
After click the number under "Ring ID", it will go to the page for Ring Configuration as followed screen:
Figure 5-9 EPRS Ring Configuration
Configuration object and description is:
Object
Description
Click Click drop-down menu to select WTR time for R-APS.
WTR(Wait to
Available selection: 1-12min
Restore) Time(1-12)
Default: 1 min
Revertive
VLAN config
Check to enable Revertive status of R-APS.
After clicked '' VLAN config '', it will go the page of Rapid Ring VLAN Configuration.
RPL Role
Click drop-down menu to select ''None'', ''RPL Owner'', or ''RPL Neighbor'' role.
RPL Port
Click drop-down menu to select ''None'', ''East Port'', or ''West Port''.
Click "Save" to store and active settings.
After clicked '' VLAN config '', it will go the page of Rapid Ring VLAN Configuration as following screen:
Figure 5-10 Rapid Ring VLAN Configuration
Click "Add New Entry" to create a new entry. Click "Save" to store and active settings.
28
Switch Web Management User Manual
Switch Web Management User Manual V2.0
5.7 LLDP
Link Layer Discovery Protocol (LLDP) is used to discover basic information about neighboring devices on
the local broadcast domain. LLDP is a Layer 2 protocol that uses periodic broadcasts to advertise
information about the sending device. Advertised information is represented in Type Length Value (TLV)
format according to the IEEE 802.1ab standard, and can include details such as device identification,
capabilities and configuration settings. LLDP also defines how to store and maintain information gathered
about the neighboring network nodes it discovers.
After Click "Advanced Configure" > "LLDP" , followed screen will appear.
Figure 5-10 LLDP Configuration Screen
Configuration object and description is:
Object
Description
LLDP Parameters
Here allows the user to inspect and configure the current LLDP port settings:
 Tx Interval: Transmission Interval Time
 Tx Hold: Hold time Multiplier
 Tx Delay: Transmit Delay Time
 Tx Remit: Transmit Remit Time
Mode
Select LLDP messages transmit and receive modes for LLDP Protocol Data
Units. Options are Tx only, Rx only, Enabled, and Disabled.
Optional TLVs
To configure the information included in the TLV field of advertised messages.
When followed option is checked, corresponding information will be included in
LLDP information transmitted.
 Port Descr: Port Description
 Sys Name: System Name
 Sys Descr: System Description
 Sys Capa: System Capability
 Mgmt Addr: Management Address
Click "Save" to store and active settings.
29
Switch Web Management User Manual
Switch Web Management User Manual V2.0
5.8 Loop Protection
Loop protection is to avoid broadcast loops. After Click "Advanced Configure" > "Loop Protection" , followed
screen will appear.
Figure 5-11 Loop Protection Configuration Screen
Configuration object and description is:
Object
Global Configuration
Description
Enable Loop Protection: click drop-down menu to disable or enable Loop
Protection;
Transmission Time: enter a number to set Loop Protection Interval Time;
Shutdown Time: enter a number to set port Shutdown Time.
Enable
Check to enable corresponding port loop protection.
Action
Action take when the port detected loop. There are 3 types of action for users to
select, Shutdown port, Shutdown port and Log, Log Only.
Tx Mode
To enable or disable Tx.
Click "Save" to store and active settings.
6. QoS Configure
Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over
network traffic. QoS enables you to assign various grades of network service to different types of traffic, such as
multi-media, video, protocol-specific, time critical, and file-backup traffic. This function n can not only reserve
bandwidth, but also limit other traffic that is not so important.
30
Switch Web Management User Manual
Switch Web Management User Manual V2.0
6.1 QoS Port Classification
After Click "QoS Configure" > "Port Classification" , followed screen will appear.
Figure 6-1 Port Classification Configuration Screen
Configuration object and description is:
Object
Description
Controls the default class of service, ranging from 0 (lowest) to 7 (highest).
All frames are classified to a CoS. There is a one to one mapping between CoS,
queue and priority. A CoS of 0 (zero) has the lowest priority
CoS
The classified CoS can be overruled by a QCL entry.
Note: If the default CoS has been dynamically changed, then the actual default CoS is
shown in parentheses after the configured default CoS.
DPL
Controls the default drop precedence level.
All frames are classified to a drop precedence level.
The classified DPL can be overruled by a QCL entry.
PCP
Controls the default PCP value.
All frames are classified to a PCP value.
If the port is VLAN aware and the frame is tagged, then the frame is classified to the
PCP value in the tag. Otherwise the frame is classified to the default PCP value.
DEI
Controls the default DEI value.
All frames are classified to a DEI value.
If the port is VLAN aware and the frame is tagged, then the frame is classified to the
DEI value in the tag. Otherwise the frame is classified to the default DEI value.
Address Mode
The IP/MAC address mode specifying whether the QCL classification must be based
on source (SMAC/SIP) or destination (DMAC/DIP) addresses on this port. The
allowed values are:
Source: Enable SMAC/SIP matching.
Destination: Enable DMAC/DIP matching.
Click "Save" to store and active settings.
31
Switch Web Management User Manual
Switch Web Management User Manual V2.0
6.2 Port Policing
After Click "QoS Configure" > "Port Policing" , followed screen will appear.
Figure 6-2 Port Policing Configuration Screen
Configuration object and description is:
Object
Enabled
Description
Check the box to enable Port Policing.
Rate
Controls the rate for the policer. The default value is 500. This value is restricted to
100-1000000 when the "Unit" is "kbps" or "fps", and it is restricted to 1-3300 when the
"Unit" is "Mbps" or "kfps".
Unit
Controls the unit of measure for the policer rate as kbps, Mbps, fps or kfps . The
default value is "kbps".
Flow Control
If flow control is enabled and the port is in flow control mode, then pause frames are
sent instead of discarding frames.
Click "Save" to store and active settings.
6.3 Storm Control Configuration
After Click "QoS Configure" > "Storm Control" , followed screen will appear.
Figure 6-3 Port Policing Configuration Screen
32
Switch Web Management User Manual
Switch Web Management User Manual V2.0
Configuration object and description is:
Object
Frame Type
Enable
Rate(pps)
Description
This switch supports 3 kinds of Frame Type: Unicast, Unknown Multicast, Broadcast.
Check the box to enable Storm Control.
The rate unit is packets per second (pps). Valid values are: 1, 2, 4, 8, 16, 32, 64, 128,
256, 512, 1K, 2K, 4K, 8K, 16K, 32K, 64K, 128K, 256K, 512K or 1024K..
Click "Save" to store and active settings.
7. Security Configure
7.1 Password
To change system login password of the switch, please click "Security Configure" > "Password" .
Figure 7-1 System Password Configuration Screen
Click "Save" to store and active settings.
7.2 802.1X
In the 802.1X-world, the user is called the supplicant, the switch is the authenticator, and the RADIUS server is
the authentication server. The switch acts as the man-in-the-middle, forwarding requests and responses between
the supplicant and the authentication server. Frames sent between the supplicant and the switch are special
802.1X frames, known as EAPOL (EAP over LANs) frames. EAPOL frames encapsulate EAP PDUs (RFC3748).
Frames sent between the switch and the RADIUS server are RADIUS packets.
RADIUS packets also encapsulate EAP PDUs together with other attributes like the switch's IP address, name,
and the supplicant's port number on the switch. EAP is very flexible, in that it allows for different authentication
methods, like MD5-Challenge, PEAP, and TLS. The important thing is that the authenticator (the switch) doesn't
need to know which authentication method the supplicant and the authentication server are using, or how many
33
Switch Web Management User Manual
Switch Web Management User Manual V2.0
information exchange frames are needed for a particular method. The switch simply encapsulates the EAP part
of the frame into the relevant type (EAPOL or RADIUS) and forwards it.
When authentication is complete, the RADIUS server sends a special packet containing a success or failure
indication. Besides forwarding this decision to the supplicant, the switch uses it to open up or block traffic on the
switch port connected to the supplicant.
The IEEE 802.1X standard defines a client-server-based access control and authentication protocol that restricts
unauthorized clients from connecting to a LAN through publicly accessible ports. The authentication server
authenticates each client connected to a switch port before making available any services offered by the switch
or the LAN.
Until the client is authenticated, 802.1X access control allows only Extensible Authentication Protocol over LAN
(EAPOL)traffic through the port to which the client is connected. After authentication is successful, normal traffic
can pass through the port.
This switch supports 802.1X port-based authentication. In this page, user can configure 802.1X. After click
"Security Configure" > "802.1X", followed screen will appear.
Figure 7-2 802.1X Configuration Screen
Configuration object and description is:
Object
System
Configuration
Port Configuration
Description
Here, user can enable or disable 802.1X or Reauthentication, as well as set
Reauthentication Period / EAPOL Timeout / Aging Period / Hold Time
Click drop-down menu to select a Admin State. Available options: Force Authorized,
Force Unauthorized, 802.1X, Mac-based Auth.
Click "Save" to store and active settings.
34
Switch Web Management User Manual
Switch Web Management User Manual V2.0
7.3 DHCP Snooping
7.3.1 DHCP Overview
DHCP protocol is widely used to dynamically allocate reusable network resources, such as IP address. A typical
process of DHCP to obtain IP is as following:
DHCP Client sent DHCP DISCOVER message to DHCP Server, if Client did not receive respond from server
within a period of time, it will resend DHCP DISCOVER message.
After received DHCP DISCOVER message, DHCP Server will assign sources (IP address for example) to client,
and then send DHCP OFFER message to DHCP Client.
After received DHCP OFFER message, DHCP Client send DHCP REQUEST to ask for server lease, and notify
the other servers that it has accepted this server to assign addresses.
After received DHCP REQUEST, server will verify whether resource can be allocated. If OK, it will send DHCP
ACK message; If not OK, it will send DHCP NAK message. After received DHCP ACK message, start using the
source which server assigned. If received DHCP NAK, DHCP Client will resend DHCP DISCOVER message.
7.3.2 About DHCP Snooping
The addresses assigned to DHCP clients on insecure ports can be carefully controlled using the dynamic
bindings registered with DHCP Snooping. DHCP snooping allows a switch to protect a network from rogue DHCP
servers or other devices which send port-related information to a DHCP server. This information can be useful in
tracking an IP address back to a physical port.
Command Usage
 Network traffic may be disrupted when malicious DHCP messages are received from an outside source.
DHCP snooping is used to filter DHCP messages received on a non-secure interface from outside the
network or firewall When DHCP snooping is enabled globally and enabled on a VLAN interface, DHCP
messages received on an untrusted interface from a device not listed in the DHCP snooping table will be
dropped
 Table entries are only learned for trusted interfaces. An entry is added or removed dynamically to the DHCP
snooping table when a client receives or releases an IP address from a DHCP server. Each entry includes a
MAC address, IP address, lease time, VLAN identifier, and port identifier.
 When DHCP snooping is enabled, DHCP messages entering an untrusted interface are filtered based upon
dynamic entries learned via DHCP snooping.
35
Switch Web Management User Manual
Switch Web Management User Manual V2.0



If a DHCP packet from a client passes the filtering criteria, it will only be forwarded to trusted ports in the
same VLAN
If a DHCP packet is from server is received on a trusted port, it will be forwarded to both trusted and
untrusted ports in the same VLAN.
If the DHCP snooping is globally disabled, all dynamic bindings are removed from the binding table.
7.3.3 DHCP Snooping Configure
After click ''Security Configure'' > ''DHCP '' > ''Snooping Setting'', following screen will appear.
Figure 7-3 DHCP Snooping Configuration Screen
Configuration object and description is:
Object
Description
DHCP Snooping Mode Click drop-down menu to enable or disable DHCP Snooping
Port Mode
Indicates the DHCP snooping port mode. Possible port modes are:
Trusted: Configures the port as trusted source of the DHCP messages.
Untrusted: Configures the port as untrusted source of the DHCP messages.
Click "Save" to store and active settings.
36
Switch Web Management User Manual
Switch Web Management User Manual V2.0
7.4 IP&MAC Source Guard
IP&MAC Source Guard is a secure feature used to restrict IP traffic on DHCP snooping untrusted ports by
filtering traffic based on DHCP Snooping Table or manually configured IP Source Bindings. It helps prevent IP
spoofing attacks when a host tries to spoof and use the IP address of another host.
7.4.1 Port Configuration
In this page, user can make IP&MAC Source Guard Port Configuration. After click ''Security Configure''>''IP &
MAC Source Guard'' >''Configuration'', followed screen will appear.
Figure 7-4 IP&MAC Guard- Port Configuration Screen
Configuration object and description is:
Object
Description
Global Mode
Click drop-down menu to enable or disable Global IP&MAC Source Guard function
Port Mode
Click drop-down menu to enable or disable the IP&MAC Source Guard function for
corresponding port.
Max Dynamic Clients
Click drop-down menu to select Max Dynamic Clients. Available options: Unlimited,
0, 1, 2.
Click "Save" to store and active settings.
37
Switch Web Management User Manual
Switch Web Management User Manual V2.0
7.4.2 Static Table
In this page, user can manually set Static Table of IP&MAC Guard to fulfill controlling function to port. After click
''Security Configure''>''IP&MAC Source Guard'' >''Static Table'', followed screen will appear.
Figure 7-5 Static Table Configuration Screen
Configuration object and description is:
Object
Port
VLAN
IP Address
MAC Address
Description
Click drop-down menu to select which port should be fixed.
Type VLAN ID that should be fixed to
Type IP Address that should be fixed to
Type Mac Address that should be fixed to
Click ''Add New Entry'' button to create a new record.
Click "Save" to store and active settings.
7.5 ARP Inspection
Dynamic ARP Inspection (DAI) is a secure feature. Several types of attacks can be launched against a host or
devices connected to Layer 2 networks by "poisoning" the ARP caches. This feature is used to block such
attacks. Only valid ARP requests and responses can go through DUT. A Dynamic ARP prevents the untrust ARP
packets based on the DHCP Snooping Database. This page provides ARP Inspection related configuration.
38
Switch Web Management User Manual
Switch Web Management User Manual V2.0
7.5.1 Port Configuration
User can make port configuration in this page. After click ''Security Configure''>''ARP Inspection'' >''Port
Configuration'', followed screen will appear.
Figure 7-6 ARP Inspection Port Configuration Screen
Configuration object and description is:
Object
Description
Global Mode
Click drop-down menu to enable or disable Global ARP Inspection
Port Mode
Click drop-down menu to enable or disable port-based ARP Inspection
Check VLAN
If you want to inspect the VLAN configuration, you have to enable the setting of
"Check VLAN". The default setting of "Check VLAN" is disabled. When the setting of
"Check VLAN" is disabled, the log type of ARP Inspection will refer to the port
setting. And the setting of "Check VLAN" is enabled, the log type of ARP Inspection
will refer to the VLAN setting. Possible setting of "Check VLAN" are:
Enabled: Enable check VLAN operation.
Disabled: Disable check VLAN operation.
Log Type
Only the Global Mode and Port Mode on a given port are enabled, and the setting of
"Check VLAN" is disabled, the log type of ARP Inspection will refer to the port
setting. There are four log types and possible types:
None: Log nothing.
Deny: Log denied entries.
Permit: Log permitted entries.
ALL: Log all entries.
Click "Save" to store and active settings.
39
Switch Web Management User Manual
Switch Web Management User Manual V2.0
7.5.2 VLAN Configuration
After click ''Security Configure''>''ARP Inspection'' >''VLAN Configuration'', followed screen will appear.
Figure 7-8 ARP Inspection VLAN Configuration Screen
Configuration object and description is:
Object
Description
VLAN ID
Indicates the ID of this particular VLAN
Log Type
Click drop-down menu to enable or disable port-based ARP Inspection.
Specify ARP Inspection is enabled on which VLANs. First, you have to enable the
port setting on Port mode configuration web page. Only when both Global Mode and
Port Mode on a given port are enabled, ARP Inspection is enabled on this given
port. Second, you can specify which VLAN will be inspected on VLAN mode
configuration web page. The log type also can be configured on per VLAN setting.
Possible types are:
None: Log nothing.
Deny: Log denied entries.
Permit: Log permitted entries.
ALL: Log all entries.
Click ''Add New Entry'' button to create a new record of VLAN configuration. Click "Save" to store and active
settings.
40
Switch Web Management User Manual
Switch Web Management User Manual V2.0
7.5.3 Static Table
User can manually configure ARP Inspection Static Table to control port. After click ''Security Configure''>''ARP
Inspection'' >''Static Table'', followed screen will appear.
Figure 7-9 Static Table Configuration Screen
Configuration object and description is:
Object
Port
VLAN
IP Address
MAC Address
Description
Click drop-down menu to select which port should be fixed.
Type VLAN ID that should be fixed to
Type IP Address that should be fixed to
Type Mac Address that should be fixed to
Click ''Add New Entry'' button to create a new record. Click "Save" to store and active settings.
7.6 ACL
ACL is an acronym for Access Control List. It is the list table of ACEs, containing access control entries that
specify individual users or groups permitted or denied to specific traffic objects, such as a process or a program.
Each accessible traffic object contains an identifier to its ACL. The privileges determine whether there are
specific traffic object access rights.
41
Switch Web Management User Manual
Switch Web Management User Manual V2.0
ACL implementations can be quite complex, for example, when the ACEs are prioritized for the various situation.
In networking, the ACL refers to a list of service ports or network services that are available on a host or server,
each with a list of hosts or servers permitted or denied to use the service. ACL can generally be configured to
control inbound traffic, and in this context,they are similar to firewalls.
7.6.1 ACL Ports Configure
After click ''Security Configure''>''ACL'' >''Ports'', followed screen will appear.
Figure 7-10 ACL Ports Configuration Screen
Configuration object and description is:
Object
Description
Action
There are 2 available options:
Permit: that specific port allows data going through.
Deny: that specific port forbid data going through.
Rate Limiter
ID
Port’s fixed Rate Limiter ID, please go to Rate Limiter Configuration for more details.
Port Redirect
Select which port frames are redirected on. The allowed values are Disabled or a specific
port number and it can't be set when action is permitted. The default value is "Disabled".
Mirror
Specify the mirror operation of this port. The allowed values are:
Enabled: Frames received on the port are mirrored.
Disabled: Frames received on the port are not mirrored.
The default value is "Disabled".
Logging
Enabled or Disabled Log
Shut Down
Specify the port shut down operation of this port. The allowed values are:
Enabled: If a frame is received on the port, the port will be disabled.
Disabled: Port shut down is disabled.
The default value is "Disabled".
Note: The shutdown feature only works when the packet length is less than 1518 (without
VLAN tags).
State
Specify the port state of this port. The allowed values are:
Enabled: To reopen ports by changing the volatile port configuration of the ACL user
module.
Disabled: To close ports by changing the volatile port configuration of the ACL user module.
The default value is "Enabled".
Counter
Counts the number of frames that match this rule.
Click "Save" to store and active settings.
42
Switch Web Management User Manual
Switch Web Management User Manual V2.0
7.6.2 Rate Limiter Configuration
User can make ACL Rate limiter configuration in this page. After click ''Security Configure''>''ACL'' >''Rate
Limiter'', followed screen will appear.
Figure 7-11 ACL Rate Limiters Configuration Screen
Click "Save" to store and active settings.
7.6.3 Access Control List Configuration
User can make Access Control List Configuration in this page . After click ''Security Configure'' >
''ACL'' >''Access Control List'', followed screen will appear.
Figure 7-12 Access Control List Configuration Screen
Click
43
button, to go to Access Control List, and edit it.
Switch Web Management User Manual
Switch Web Management User Manual V2.0
8. Diagnostics
8.1 Ping Test
Ping is a little program that can issue ICMP Echo packets to the IP address you defined. Destination node will
respond to those packets sent from switch. So Ping test is to troubleshoot IP connectivity issues.
After click ''Diagnostics ''>''Ping'', followed screen appear.
Figure 8-1 Ping Test Screen
Configuration object and description is:
Object
Description
IP Address
The destination IP Address that needed to Ping
Ping Length
Input a number between 1 and 1452. Default: 56
Ping Count
The times for inputting Ping IPv4 address or IPv6 address (Number of echo requests to
send). User can input a number between 1 and 60.
Ping Interval
Interval time for Ping (Send interval for each ICMP packet)
Click ''Start'' button to start Ping testing.
44
Switch Web Management User Manual
Switch Web Management User Manual V2.0
8.2 Cable Diagnostics
The Cable Diagnostics performs tests on 10/100/1000BASE-T copper cables. These functions have the ability to
identify the cable length and operating conditions, and to isolate a variety of common faults that can occur on the
Cat5 twisted-pair cabling.
After click ''Diagnostics ''>''Cable Diagnostics'', followed screen will appear.
Figure 8-2 Cable Diagnostics Screen
Click ''Start'' button to start ''Cable Diagnostics'' testing.
8.3 CPU Load
This page shows percent of CPU load. After click ''Diagnostics''>''CPU Load'', followed screen will appear.
Figure 8-3 CPU Load Screen
45
Switch Web Management User Manual
Switch Web Management User Manual V2.0
9. Maintenance
9.1 Restart Device
This page is for restarting switch. After click ''Maintenance ''>''Restart Device'', followed screen will appear.
Please click ''Yes'' to restart the switch.
9.2 Factory Defaults
This page is for making all settings to factory defaults. After click ''Maintenance ''>''Factory Defaults'', followed
screen will appear.
Please click ''Yes'' to reset the configuration to Factory Defaults.
46
Switch Web Management User Manual
Switch Web Management User Manual V2.0
9.3 Firmware Upgrade
This page is for upgrading system firmware. After click ''Maintenance ''>''Firmware Upgrade'', followed
screen will appear.
Please click ''Browse'' to select the firmware that needed to upgrade. And then click ''Upload '' to start
upgrading.
9.4 Firmware Select
This page is for upgrading system firmware. After click ''Maintenance ''>''Firmware Upgrade'', followed
screen will appear.
Please click ''Activate Alternate Image'' to select the firmware.
47
Switch Web Management User Manual
Switch Web Management User Manual V2.0
9.5 Firmware Select
In this page, user can download, upload, activated or delete configuration files.
9.5.1 Download Configuration File
After click ''Maintenance ''>''Download'', followed screen will appear.
Please choose a file and then click ''Download Configuration'' button to download.
9.5.2 Upload Configuration File
After click ''Maintenance ''>''Upload'', followed screen will appear. Then user can upload Configuration File.
48
Switch Web Management User Manual
Switch Web Management User Manual V2.0
9.5.3 Activate Configuration
After click ''Maintenance ''>''Activate'', followed screen will appear. Then user can activate Configuration File.
9.5.4 Delete Configuration File
After click ''Maintenance ''>''Delete'', followed screen will appear. Then user can delete Configuration File.
------------The End-----------