Rackmount Light
features:
with power distribution
• Retractable LED light
rackmount light with power
distribution
PDLT-815RV-RN
• Dimmable LED bar provides evenly distributed illumination for component viewing
• 2 rear USB style output ports for connection of LED gooseneck work lights
front view
• 8 circuit-breaker protected NEMA 5-15R rear outlets
• 2 stage surge suppression protects against damage from power surges
and spikes (status notification via local LED and dry contact warns when surge
protection is compromised, PDLT-815RV-RN only)
• Constructed of 18-gauge steel
rear view
PDLT-815RVA
• “Clean ground” surge suppressor design will not pass noise contamination
to the ground
front view
• Face available with flat black powder coat finish (PDLT-815RV-RN), black
brushed anodized finish (PDLT-815RVA)
rear view
specifications:
• ETL Listed in the US and Canada
PDLT-815RV-RN
Rackmount light with power distribution, normally open dry contact closure for remote surge suppression status notification
to customer supplied monitoring device and LED status indicators shall be Middle Atlantic Products model #PDLT-815RV-RN.
Rackmount power shall have a 15 amp capacity, 2 stage, normal mode, surge and spike protection and EMI filtering.
Rackmount power / light unit shall operate on 120 volt nominal AC/60Hz power. Rackmount power / light unit shall include 9’
(14-3) SignalSAFE™ power cord with NEMA 5-15P plug with 8 rear NEMA 5-15R outlets and 15 amp circuit breaker located on
the front. Rackmount power shall feature retractable light shelf with 20 lb. weight capacity and LED light bar. Unit shall include
dimmer (front mounted knob.) “Clean ground” surge suppressor design shall not pass noise contamination to the ground. Unit
shall occupy one rackspace and be constructed of 18-gauge steel with a flat black powder coat finish. Rackmount power / light
unit shall feature 2 rear USB style output ports for use with optional LED gooseneck work lights. Rackmount power / light unit
shall be warrantied to be free from defects in material or workmanship under normal use and conditions for a period of three
years. Rackmount power / light shall by manufactured by an ISO 9001 Registered Company. Rackmount power / light shall
comply with the requirements of RoHS EU Directive 2011/95/EC. Rackmount power/light unit shall be ETL listed to UL
standard 1419, UL 60950-1 and UL 60065 in the US; CSA standard 60950-1, and CSA C22.2 No. 60065 in Canada.
Rackmount power / light shall be warrantied to be free from defects in materials and workmanship under normal use and
conditions for a period of 3 years.
options:
• LED work light with 11” flexible gooseneck and
on/off switch shall be Middle Atlantic Products
model # LT-GN
PDLT-815RVA
Rackmount light with power distribution shall be Middle Atlantic Products model # PDLT-815RVA. Rackmount power shall have
a 15 amp capacity, 2 stage, normal mode, surge and spike protection and EMI filtering. Rackmount power / light unit shall
operate on 120 volt nominal AC/60Hz power. Rackmount power / light unit shall include 9’ (14-3) SignalSAFE™ power cord
with NEMA 5-15P plug with 8 NEMA 5-15R outlets and 15 amp circuit breaker located on the front. Rackmount power shall
feature retractable light shelf with 20 lb. weight capacity and LED light bar. Unit shall include dimmer button under light shelf.
Second dimmer button shall control brightness of the lighted logo. “Clean ground” surge suppressor design shall not pass noise
contamination to the ground. Unit shall occupy one rackspace and be constructed of 18-gauge steel. Rackmount power / light
unit shall feature 2 rear USB style output ports for use with optional LED gooseneck work lights. Rackmount power / light unit
shall be warrantied to be free from defects in material or workmanship under normal use and conditions for a period of three
years. Rackmount power / light shall by manufactured by an ISO 9001 Registered Company. Rackmount power / light shall
comply with the requirements of RoHS EU Directive 2011/95/EC. Rackmount power/light unit shall be ETL listed to UL standard
1419, UL 60950-1 and UL 60065 in the US; CSA standard 60950-1, and CSA C22.2 No. 60065 in Canada. Rackmount power
/ light shall be warrantied to be free from defects in materials
Customizable specification clips available at middleatlantic.com
EIA/TIA COMPLIANT
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca
96-01044 / rev b / 11-1-16
PDLT
basic dimensions
all dimensions in inches unless otherwise noted [all dimensions in brackets are in millimeters]
top view
rear view
17.58 [447]
surge status terminal block (PDLT-815RV-RN only)
usb ports for gooseneck light
Middle Atlantic part #LT-GN
electrical bonding point
8.87
[225]
Surge Suppression Status
Stage 1
Indicator
Stage 2
Indicator
on
on
Full protection
off
on
Stage 1 compromised
Stage 2 active
off
off
Load unprotected
or power off
PDLT-815RVA
front view
PDLT-815RV-RN
front view
13.37 [340]
19.00 [483]
13.37 [340]
Status
1.74 [44]
PDLT-815RVA and PDLT-815RV-RN dimmer for light and logo
is located under drawer, ref inst sheet I-00175
side view
side view
.60 [15]
10' linecord
NEMA-5-15P
(SignalSAFE™)
light drawer open
3.00
[76]
Note: UL File # E204950
Part#
Front Power Switch
Remote Notifier
Dimmable Logo
Finish
PDLT-815RV-RN
yes
yes
no
Flat black powder coat
PDLT-815RVA
no
no
yes
Black brushed anodized aluminum face
Maximum Derated Load (North America):
15 Amp Models: 12 Amps
20 Amp Models: 16 Amps
surge suppression & EMI filter specifications (PDLT-815RV / PDLT-815RVA)
• Maximum allowable voltage: 125 VAC (RMS)
-Maximum continuous voltage differential applied between
line and neutral
• Peak impulse current (8/20 micro seconds):
-30,000 Amps, one time
-19,500 Amps, two times within 5 minutes
-7,000 Amps, ten times within 2 minutes
-Maximum peak impulse current pulse as defined between
line and neutral
-Maximum multiple impulse current derated per spec
• Maximum clamping voltage: 545 Volts @ 100 Amps
• Response time: Instantaneous (Less than 1 nanosecond)
• EMI/RF Suppression: More than 20 db
-Calculated line to neutral, 100 KHz to 1 MHz suppression
based upon nominal impedance
• Surge energy dissipation: 711 Joules (10 / 100 micro seconds)
• 2 Stage surge suppression with health indicators
• Surge suppression circuit does not contaminate ground
• Protection mode: Line to Neutral
what great systems are built on.
™
middleatlantic.com | middleatlantic.ca