ALCATEL-LUCENT OMNISWITCH 6900

Add to my manuals
7 Pages

advertisement

ALCATEL-LUCENT OMNISWITCH 6900 | Manualzz

ALCATEL-LUCENT

OMNISWITCH 6900

STACKABLE LAN SWITCHES

The Alcatel-Lucent OmniSwitch™ 6900 Stackable LAN Switches are compact, high-density

10 Gigabit Ethernet (GE) and 40 GE platforms designed for the most demanding networks.

These platforms offer unmatched versatility to actually deliver on the promise of the nextgeneration virtualized data center. With their modular approach, these platforms accommodate the exact rack configuration and exact oversubscription ratio required by the application flows.

In addition to high performance and extremely low latency, the OmniSwitch 6900 platforms offer extensive QoS and Layer 2 and Layer 3 switching, as well as system- and network-level resiliency. They can be positioned as top of rack switches in a data center, as well as core/ aggregation switches in a converged campus network. .

OS6900-X20 with OS-HNI-U6 and OS6900-X40 with OS-QNI-U3 front view

OS6900-X20 and OS6900-X40 with OS-XNI-U12 back view

FEATURES

High performance

Redundant hardware system architecture. Internal, hot-swappable power supplies, fans. Front-to-back and back-to-front cooling models

High 10 GE port density in 1RU.

• Up to 32 fixed SFP+ ports for the OS6900-X20

• Up to 64 fixed SFP+ ports for the OS6900-X40

Through the use of optional modules, the

OmniSwitch 6900 can offer the highest

10 GE port density in its class, with up to 64 10 GE ports in a 1U form factor.

This modularity also allows for up to six

40 GE uplink ports. With a leading power consumption model, the OS6900 product family is the most efficient and versatile switch in its class.

BENEFITS

Up to 1.28 terabits per second (Tb/s) of wire-rate capacity, sub-microsecond latency for high-performance server and core connectivity

Resiliency maximizes uptime for converged mission-critical networks

Increases density in a single rack and supports next-generation service densities with a very high port density in a 1U form factor. Modular slots offer versatility in terms of 40 GE uplinks and resulting oversubscription

Lowest power consumption per 10 GE port in its class

Virtual Network Profile

Ensures efficient power management, reduces operating expenses and lowers total cost of ownership (TCO) through the low power consumption.

Building on the Alcatel-Lucent concept of mobile VLAN, the OmniSwitch 6900 offers mobile network services for virtual machines that are added, moved and changed across the data center. Combined with a very large MAC table, the

OmniSwitch 6900 provides support for virtualized data centers

Outstanding performance when supporting real-time voice, data, and video applications for converged scalable networks

Wire-rate performance for switching and routing at

40 G, 10 G and gigabit speeds. Advanced services are incorporated in the operating system: QoS, access control lists (ACLs), L2/L3, VLAN stacking and IPv6.

Hardware-based virtual routing and forwarding

(VRF) support

Reduces cost across the enterprise through hardware consolidation that achieves network segmentation and security without additional hardware installation

Alcatel-Lucent OmniSwitch

6900 models

The OmniSwitch 6900 family offers customers high-performance, very low latency Layer 2/Layer 3 10 Gigabit

Ethernet switches. All models are in

1RU form factor with redundant power supplies and fan trays, and front-to-back and back-to-front airflow. A wide range of 40 GE and 10 GE optional modules are supported, allowing for maximum flexibility and investment protection as customers migrate to 10 GE connectivity with 40 GE uplinks.

The OmniSwitch 6900-X40 has 40 fixed

SFP+ ports and one expansion slot on the front panel. It also supports one expansion slot on the back of the device.

The OmniSwitch 6900-X20 has 20 fixed

SFP+ ports and one expansion slot on the front panel.

Power supplies

All OmniSwitch 6900 models support 1+1 redundant, hot-swappable AC and DC power supplies. The primary and backup power supply units are internal, but removable allowing for easier maintenance and replacement.

There is no interruption of service when a new power supply is installed or an old one replaced.

Table 1. Product matrix

PRODUCT MATRIX

Port count (SFP+ )

Expansion slots

Out of band 10/100/1000 port

USB port

Console port

AC/DC redundant PSU

Redundant fans

Flash

Memory

Maximum switching capacity (Gb/s)

Throughput (Mp/s

Latency

Table 2. Expansion Module Matrix

EXPANSION MODULES

40 Gb port count (QSFP+)

10 Gb port count ( SFP+)

Switching capacity

Hot swappable/interchangeable

Power consumption

Heat dissipation

OS-XNI-U12

0

12

240 Gb/s

Yes

44 watts

150.13 BTU/hour

OS6900-X40

40

2 (front and back)

1

1

1

Yes

Yes (3+1)

2 GB

2 GB

1,280 Gb/s

960 Mp/s

Sub microsecond

OS-XNI-U4

0

4

80 Gb/s

Yes

19 watts

64.83 BTU/hour

Table 3. Power supplies

PS MODELS

OS6900-BP-F

OS6900-BP-R

OS6900-BPD-F

OS6900-BPD-R

DESCRIPTION

Modular AC backup power supply. Front-to-back cooling.

Provides 450 W AC system power to one OS6900 device.

Modular AC backup power supply. Rear-to-front cooling.

Provides 450 W AC system power to one OS6900 device.

Modular DC backup power supply. Front-to-back cooling.

Provides 450 W AC system power to one OS6900 device.

Modular DC backup power supply. Rear-to-front cooling.

Provides 450 W AC system power to one OS6900 device.

OS-HNI-U6

2

4

240 Gb/s

Yes

37 watts

126.25 BTU/hour

DIMENSIONS (W X D X H)

50.5 x 30 x 40.2 cm

(19.9 x 11.8 x 15.8 in)

50.5 x 30 x 40.2 cm

(19.9 x 11.8 x 15.8 in)

50.5 x 30 x 40.2 cm

(19.9 x 11.8 x 15.8 in)

50.5 x 30 x 40.2 cm

(19.9 x 11.8 x 15.8 in)

OS6900-X20

20

1 (front)

1

1

1

Yes

Yes (3+1)

2 GB

2 GB

640 Gb/s

480 Mp/s

Sub microsecond

OS-QNI-U3

3

0

240 Gb/s

Yes

34 watts

116 BTU/hour

WEIGHT

2.6 lb (1.2 kg)

2.6 lb (1.2 kg)

2.6 lb (1.2 kg)

2.6 lb (1.2 kg)

OmniSwitch 6900

ALCATEL-LUCENT DATA SHEET

2

Table 4. OmniSwitch 6900 power consumption, heat dissipation, MTBF and weights

PRODUCT

OS6900-X20

MTBF

(HOURS)*

146520

POWER CONSUMPTION

(WATTS)**

181

HEAT DISSIPATION

(BTU/HOUR)

617.60

OS6900-X40 141490 242 825.74

* MTBF for the switch with one AC power supply

** Maximum power consumption under full L2 traffic load; no plug-in modules

*** Fully populated chassis includes fan tray, 2 power supplies, all plug-in modules and no transceivers

WEIGHTS (CHASSIS

AND FAN TRAY ONLY)

7.61 kg (16.8 lbs)

7.78 kg (17.15 lbs)

WEIGHTS (CHASSIS

FULLY POPULATED)***

10.21 kg (22.5 lbs)

10.86 kg (23.95 lbs)

TECHNICAL SPECIFICATIONS

Physical dimensions

• Width: 48.2 cm (19.00 in.)

• Depth: 55.9 cm (22.00 in.)

• Height: 4.4 cm (1.73 in.)

Indicators

• Per-port LEDs

¬ SFP+: link/activity

¬ EMP: link/activity

• System LEDs

¬ OK: green/yellow

¬ PS1: green/yellow

¬ PS2: green/yellow

¬ PWR Save: green

Environmental requirements

• Operating temperature: 0°C to 45°C

(32°F to 113°F) for all front-to-backcooling models

• Operating temperature: 0°C to 40°C

(32°F to 104°F) for all back-to-frontcooling models

• Storage temperature: -10°C to +70°C

(14°F to 158°F)

• Humidity (operating): 5% to 90% non-condensing

• Humidity (storage): 5% to 95% non-condensing

DETAILED PRODUCT FEATURES

Simplified manageability

• Intuitive Alcatel-Lucent Command Line

Interface (CLI) in a BASH environment

• Full configuration and reporting using

SNMPv1/2/3 across all OmniSwitch families to facilitate third-party network management

• Local (on the flash) and remote server logging: Syslog and command log

• Policy and port-based mirroring

• Remote port mirroring

• sFlow v5 and RMON

• UDLD and DDM

• File upload using USB, TFTP, FTP, SFTP or SCP

• BOOTP/DHCP client with option 60

• DHCP relay

• IEEE 802.1AB LLDP with MED extensions

• NTP client and server

Resiliency and high availability

• Multi-chassis Link Aggregation (MC-LAG)

• ITU-T G.8032 Ethernet Ring Protection

• IEEE 802.1s Multiple Spanning Tree

Protocol (MSTP) encompasses IEEE 802.1D

Spanning Tree Protocol (STP) and IEEE

802.1w Rapid Spanning Tree Protocol

(RSTP)

• Per-VLAN spanning tree (PVST+) and

Alcatel-Lucent 1x1 STP mode

• IEEE 802.3ad Link Aggregation Control

Protocol (LACP) and static LAG groups across modules

• Dual-home link support for sub-second link protection without STP*

• Virtual Router Redundancy Protocol

(VRRP)

• Bidirectional Forwarding Detection (BFD)

• Redundant and hot-swappable power supplies

• Redundant fans (3+1)

• Hot swappable fan tray

• Hot swappable optional modules

Data center networking

• Virtual Network Profiles (VNP)

• Priority Flow Control (PFC)

– IEEE802.1Qbb*

• Enhanced Transmission Selection

(ETS) – IEEE802.1Qaz*

• DCBX*

• Shortest Path Bridging (SPB)

– IEEE802.1aq*

• Edge Virtual Bridging (EVB)

– IEEE802.1Qbg*

• Centralized RADIUS and Lightweight

Directory Access Protocol (LDAP) administrator authentication

• Learned Port Security (LPS) or MAC address lockdown

• Bridge Protocol Data Unit (BPDU) blocking

• STP Root Guard

• Access Control Lists (ACLs); flow-based filtering in hardware (Layer 1 to Layer 4)

Quality of Service (QoS)

• Priority queues: 8 hardware-based queues per port

• Traffic prioritization: Flow-based QoS

• Flow-based bandwidth management

• Queue management with configurable scheduling algorithms

• RED, WRED

• DiffServ architecture

• Congestion avoidance: Support for endto-end Head-of-Line (E2E-HOL) blocking prevention and flow control

IPv4 routing

• Multiple Virtual and Forwarding (VRF)

• Static routing, Routing Information

Protocol (RIP) v1 and v2

• Open Shortest Path First (OSPF) v2 with graceful restart

• Border Gateway Protocol (BGP) v4 with graceful restart

• Generic Routing Encapsulation (GRE) and IP/IP tunneling

• VRRP v2

• DHCP relay (including generic UDP relay)

• ARP

Advanced security

Access control

• SSH with public key infrastructure

(PKI) support

• TACACS+ client

IPv6 routing

• Static routing

• Routing Information Protocol Next

Generation (RIPng)

• OSPF v3

• BGP v4 (with extensions to IPv6 routing)

• Graceful restart extensions for OSPF and BGP

• VRRPv3

• NDP

OmniSwitch 6900

ALCATEL-LUCENT DATA SHEET

3

IPv4/IPv6 multicast

• Internet Group Management Protocol

(IGMP) v1/v2/v3 snooping

• Protocol Independent Multicast – Sparse

Mode (PIM-SM) ASM and SSM

• Protocol Independent Multicast – Dense

Mode (PIM-DM)

• Distance Vector Multicast Routing

Protocol (DVMRP)

• Multicast Listener Discovery (MLD) v1/v2 snooping

Advanced Layer 2 services

• Ethernet services support per IEEE

802.1ad Provider Bridges (also known as Q-in-Q or VLAN stacking):

¬ Service VLAN (SVLAN) and Customer

VLAN (CVLAN) transparent LAN services

¬ Ethernet network-to-network interface

(NNI) and user network interface (UNI) services

¬ Service Access Point (SAP) profile identification

¬ CVLAN to SVLAN translation and mapping

• Port mapping

• DHCP Option 82: Configurable relay agent information

• Multicast VLAN Registration Protocol

(MVRP)

• HA-VLAN

COMPLIANCE AND

CERTIFICATIONS

Commercial

EMI/EMC

• FCC 47 CFR Part 15 Class A

• ICES-003 Class A

• 89/336/EEC EMC Directive

• EN55022:1998 Class A

• EN55024 :1998

• EN61000-42

• EN61000-4-3

• EN61000-4-4

• EN61000-4-5

• EN61000-4-6

• EN61000-4-8

• EN61000-4-11

• EN61000-3-2,

• EN61000-3-3

• CISPR22:1997 Class A

• VCCI (Class A)

• AS/NZS 3548 (Class A)

• IEEE 802.3 Hipot requirement and

1.5 kV surge on data port for copper interfaces

Safety agency certifications

• US UL 60950

• IEC 60950-1:2001; all national deviations

• EN 60950-1: 2001; all deviations

• CAN/CSA-C22.2 No. 60950-1-03

• AS/NZ TS-001 and 60950:2000, Australia

• UL-AR, Argentina

• UL-GS Mark, Germany

• GOST, Russian Federation

• EN 60825-1 Laser

• EN 60825-2 Laser

• CDRH Laser

OSPF

• RFC 1253/1850/2328 OSPF v2 and MIB

• RFC 1587/3101 OSPF NSSA Option

• RFC 1765 OSPF Database Overflow

• RFC 2154 OSPF MD5 Signature

• RFC 2370/3630 OSPF Opaque LSA

• RFC 2740 OSPFv3 for IPv6

• RFC 3623 OSPF Graceful Restart

RIP

• RFC 1058 RIP v1

• RFC 1722/1723/2453/1724 RIP v2 and

MIB

• RFC 1812/2644 IPv4 Router Requirements

• RFC 2080 RIPng for IPv6

SUPPORTED STANDARDS

IEEE standards

• IEEE 802.1D (STP)

• IEEE 802.1p (CoS)

• IEEE 802.1Q (VLANs)

• IEEE 802.1ad (Provider Bridges)

(Q-in-Q/VLAN stacking)

• IEEE 802.1ak (Multiple VLAN Registration

Protocol)

• IEEE 802.1aq (SPB)*

• IEEE 802.1Qaz (ETS)*

• IEEE 802.1Qbb (PFC)*

• IEEE 802.1s (MSTP)

• IEEE 802.1w (RSTP)

• IEEE 802.3i (10Base-T)

• IEEE 802.3u (Fast Ethernet)

• IEEE 802.3x (Flow Control)

• IEEE 802.3z (Gigabit Ethernet)

• IEEE 802.3ab (1000Base-T)

• IEEE 802.3ac (VLAN Tagging)

• IEEE 802.3ad (Link Aggregation)

• IEEE 802.3ae (10 G Ethernet)

• IEEE 802.3ba (40 G Ethernet)*

ITU-T standards

• ITU-T G.8032: Draft (June 2007) Ethernet

Ring Protection

IETF standards

IPv4

• RFC 2003 IP/IP Tunneling

• RFC 2784 GRE Tunneling

BGP

• RFC 1269/1657 BGP v3 and v4 MIB

• RFC 1403/1745 BGP/OSPF Interaction

• RFC 1771-1774/2842/2918/3392/4271

BGP v4

• RFC 1965 BGP AS Confederations

• RFC 1966 BGP Route Reflection

• RFC 1997/1998 BGP Communities Attribute

• RFC 2042 BGP New Attribute

• RFC 2385 BGP MD5 Signature

• RFC 2439 BGP Route Flap Damping

• RFC 2545 BGP-4 Multiprotocol Extensions for IPv6 Inter-Domain Routing

• RFC 2796 BGP Route Reflection

• RFC 2858/4760 Multiprotocol Extensions for BGP-4

• RFC 3065 BGP AS Confederations

IP multicast

• RFC 1075 DVMRP

• RFC 1112 IGMP v1

• RFC 2236/2933 IGMP v2 and MIB

• RFC 2362/4601/5059 PIM-SM

• RFC 2365 Multicast

• RFC 2715/2932 Multicast Routing MIB

• RFC 2934 PIM MIB for IPv4

• RFC 3376 IGMPv3

• RFC 5060 Protocol Independent

Multicast MIB

• RFC 5132 IP Multicast MIB

• RFC 5240 PIM Bootstrap Router MIB

• RFC 2710/3019/3810/MLD v2 for IPv6

OmniSwitch 6900

ALCATEL-LUCENT DATA SHEET

4

IPv6

• RFC 1886/3596 DNS for IPv6

• RFC 1981 Path MTU Discovery for IPv6

• RFC 2292/2553/3493/3542 IPv6 Sockets

• RFC 2373/2374/3513/3587/ 4291 IPv6

Addressing

• RFC 4007 IPv6 Scoped Address

Architecture

• RFC 4193 Unique Local IPv6 Unicast

Addresses

• RFC 2460//2462/2464 Core IPv6

• RFC 2461 NDP

• RFC 2463/2466/4293/4443 ICMP v6 and MIB

• RFC 2452/2454 IPv6 TCP/UDP MIB

• RFC 2711 IPv6 Router Alert Option

• RFC 2893/4213 IPv6 Transition

Mechanisms

• RFC 3056 IPv6 Tunneling

• RFC 3484 Default Address Selection IPv6

• RFC 3542/3587 IPv6

• RFC 3595 TC for Flow Label

Manageability

• RFC 959/2640 FTP

• RFC 1350 TFTP Protocol

• RFC 2131 DHCP Server/Client

• RFC 854/855 Telnet and Telnet options

• RFC 1155/2578-2580 SMI v1 and SMI v2

• RFC 1157/2271 SNMP

• RFC 1212/2737 MIB and MIB-II

• RFC 1213/2011-2013 SNMP v2 MIB

• RFC 1215 Convention for SNMP Traps

• RFC 1573/2233/2863 Private Interface

MIB

• RFC 1643/2665 Ethernet MIB

• RFC 1901-1908/3416-3418 SNMP v2c

• RFC 2096 IP MIB

• RFC 2570-2576/3411-3415 SNMP v3

• RFC 2616 /2854 HTTP and HTML

• RFC 2667 IP Tunneling MIB

• RFC 2668/3636 IEEE 802.3 MAU MIB

• RFC 2674 VLAN MIB

• RFC 3414 User-based Security Model

• RFC 4251 Secure Shell Protocol

Architecture

• RFC 4252 The Secure Shell (SSH)

Authentication Protocol

Security

• RFC 1321 MD5

• RFC 2104 HMAC Message Authentication

• RFC 2138/2865/2868/3575 /2618

RADIUS Authentication and Client MIB

• RFC 2139/2866/2867/2620 RADIUS

Accounting and Client MIB

• RFC 2228 FTP Security Extensions

• RFC 2284 PPP EAP

• RFC 2869/2869bis RADIUS Extension

• RFC 4301 Security Architecture for IP

• RFC 1826/1827/4303/4305 Encapsulating

Payload (ESP) and cryto algorithms

QoS

• RFC 896 Congestion Control

• RFC 1122 Internet Hosts

• RFC 2474/2475/2597/3168/3246

DiffServ

• RFC 3635 Pause Control

• RFC 2697 srTCM

• RFC 2698 trTCM

Others

• RFC 791/894/1024/1349 IP and

IP/Ethernet

• RFC 792 ICMP

• RFC 768 UDP

• RFC 793/1156 TCP/IP and MIB

• RFC 826/903 ARP and Reverse ARP

• RFC 919/922 Broadcasting Internet

Datagram

• RFC 925/1027 Multi-LAN ARP/Proxy ARP

• RFC 950 Subnetting

• RFC 951 BOOTP

• RFC 1151 RDP

• RFC 1191 Path MTU Discovery

• RFC 1256 ICMP Router Discovery

• RFC 1305/2030 NTP v3 and Simple NTP

• RFC 1493 Bridge MIB

• RFC 1518/1519 CIDR

• RFC 1541/1542/2131/3396/3442 DHCP

• RFC 1757/2819 RMON and MIB

• RFC 2131/3046 DHCP/BootP Relay

• RFC 2132 DHCP Options

• RFC 2251 LDAP v3

• RFC 2338/3768/2787 VRRP and MIB

• RFC 3021 Using 31-bit Prefixes

• RFC 3060 Policy Core

• RFC 3176 sFlow

OmniSwitch 6900

ALCATEL-LUCENT DATA SHEET

5

Table 3. OmniSwitch 6900 ordering information

MODULES

OS6900-X20-F-xx

OS6900-X20D-F

OS6900-X40-F-xx

OS6900-X40D-F

OS6900-X20-R-xx

OS6900-X20D-R

OS6900-X40-R-xx

OS6900-X40D-R

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 20 SFP+ ports, one optional module slot. The chassis includes a 450 W AC power supply. Front-to-back cooling. –xx to be replaced with the country-specific power cord code (e.g. –EU for Europe).

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 20 SFP+ ports, one optional module slot. The chassis includes a 450 W DC power supply. Front-to-back cooling.

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 40 SFP+ ports, two optional module slots. The chassis includes a 450 W AC power supply. Front-to-back cooling. –xx to be replaced with the country-specific power cord code (e.g. –EU for Europe).

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 40 SFP+ ports, two optional module slots. The chassis includes a 450 W DC power supply. Front-to-back cooling.

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 20 SFP+ ports, one optional module slot. The chassis includes a 450 W AC power supply. Rear-to-front cooling. –xx to be replaced with the country-specific power cord code (e.g. –EU for Europe).

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 20 SFP+ ports, one optional module slot. The chassis includes a 450 W DC power supply. Rear-to-front cooling.

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 40 SFP+ ports, two optional module slots. The chassis includes a 450 W AC power supply. Rear-to-front cooling. –xx to be replaced with the country-specific power cord code (e.g. –EU for Europe).

10 Gigabit Ethernet L2/L3 fixed-configuration chassis in a 1U form factor with 40 SFP+ ports, two optional module slots. The chassis includes a 450 W DC power supply. Rear-to-front cooling.

PLUG-IN MODULES

OS-XNI-U12

OS-XNI-U4

OS-HNI-U6

OS-QNI-U3

10 Gigabit Ethernet Optional Module for the OS6900 series of switches. Supports 12 SFP+ ports.

10 Gigabit Ethernet Optional Module for the OS6900 series of switches. Supports 4 SFP+ ports.

Optional Module for the OS6900 series of switches. Supports 2 QSFP+ ports and 4 SFP+ ports.

40 Gigabit Ethernet Optional Module for the OS6900 series of switches. Supports 3 QSFP+ ports.

BACKUP POWER SUPPLIES

OS6900-BP-F

OS6900-BPD-F

OS6900-FT-F

OS6900-BP-R

OS6900-BPD-R

OS6900-FT-R

SOFTWARE

OS6900-SW-AR

GE TRANSCEIVERS

SFP-GIG-T

SFP-GIG-SX

SFP-GIG-LX

SFP-GIG-LH40

SFP-GIG-LH70

10 GE TRANSCEIVERS

SFP-10G-SR

SFP-10G-LR

SFP-10G-ER

SFP-10G-LRM

Modular AC backup power supply. Front-to-back cooling. Provides backup system power to one 6900 switch

Modular DC backup power supply. Front-to-back cooling. Provides backup system power to one 6900 switch

OS6900 replacement fan tray; front-to-back cooling.

Modular AC backup power supply. Back-to-front cooling. Provides backup system power to one 6900 switch

Modular DC backup power supply. Back-to-front cooling. Provides backup system power to one 6900 switch

OS6900 replacement fan tray; back-to-front cooling.

Advanced routing software license. Includes BGP, OSPF, PIM-SM/DM, DVMRP

1000Base-T Gigabit Ethernet Transceiver (SFP MSA). SFP works at 1000 Mb/s speed and full-duplex mode.

1000Base-SX Gigabit Ethernet optical transceiver (SFP MSA).

1000Base-LX Gigabit Ethernet optical transceiver (SFP MSA).

1000Base-LH Gigabit Ethernet optical transceiver (SFP MSA). Typical reach of 40 km on 9/125 μm SMF.

1000Base-LH Gigabit Ethernet optical transceiver (SFP MSA). Typical reach of 70 km on 9/125 μm SMF.

10 Gigabit optical transceiver (SFP+). Supports multimode fiber over 850 nm wavelength (nominal) with an

LC connector. Typical reach of 300 m

10 Gigabit optical transceiver (SFP+). Supports monomode fiber over 1310 nm wavelength (nominal) with an

LC connector. Typical reach of 10 km

10 Gigabit optical transceiver (SFP+). Supports monomode fiber over 1550 nm wavelength (nominal) with an

LC connector. Typical reach of 40 km

10 Gigabit optical transceiver (SFP+). Supports multimode fiber over 1310 nm wavelength (nominal) with an

LC connector. Typical reach of 220 m on FDDI-grade (62.5μm)

OmniSwitch 6900

ALCATEL-LUCENT DATA SHEET

6

MODULES

SFP+ DIRECT ATTACHED CABLES

SFP-10G-C1M

SFP-10G-C3M

10 Gigabit direct attached copper cable (1 m, SFP+).

10 Gigabit direct attached copper cable (3 m, SFP+).

SFP-10G-C7M

40 GE TRANSCEIVERS

10 Gigabit direct attached copper cable (7 m, SFP+).

QSFP-40G-SR Four channel 40 Gigabit optical transceiver (QSFP+).

Supports link lengths of 100 m and 150 m, respectively, on OM3 and OM4 multimode fiber cables.

QFP+ DIRECT ATTACHED CABLES

QSFP-40G-C1M 40 Gigabit direct attached copper cable (1 m, QSFP+).

QSFP-40G-C3M

QSFP-40G-C7M

40 Gigabit direct attached copper cable (3 m, QSFP+).

40 Gigabit direct attached copper cable (7 m, QSFP+).

SERVICE AND SUPPORT

Warranty

Limited lifetime hardware warranty:

Limited to the original owner and will be provided for up to 5 years after the product’s End-of-Sales announcement.

* Roadmap item www.alcatel-lucent.com

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of

Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.

Copyright © 2012 Alcatel-Lucent. All rights reserved. 2012013948 (March)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals