DA-11033
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Overview
HP StorageWorks Modular SAN
Array 1000 for Microsoft, Linux,
and NetWare environments
The HP StorageWorks Modular SAN Array 1000 is a 2 Gb Fibre Channel storage system designed for the entrylevel to mid-range Storage Area Network (SAN). Designed to reduce the complexity, expense and risk of SAN
deployment, the msa1000 is a scaleable, high performance storage system built with investment protection in
mind. The modular design of the msa1000 allows the user to easily add storage capacity on an as needed basis.
The msa1000 combines the array controller shelf and the drive shelf, which holds up to fourteen 1″ universal disk
drives in a single 4U rackmount cabinet. More storage can be easily deployed with the addition of up to two HP
StorageWorks 4314 (max 42 drives) or one 4354 (max 28 drives) Enclosures for a maximum storage capacity of 6
TB when using the new 146 GB drives. The msa1000 provides the latest 2 Gb Fibre Channel technology to the
hosts. Besides the single port 2 Gb Fibre Channel I/O module that comes standard, there is an optional 8-port, 2
Gb Fibre Channel fabric switch that fits inside the msa1000. Another optional I/O module is a 3-port 2 Gb Fibre
Channel hub that also fits inside – an ideal low cost solution for simple 2-node clustering. The msa1000 provides
Ultra3 SCSI connections to the hard drives and uses the HP Universal 1″ Ultra2, Ultra3, and Ultra320 drives. By
utilizing existing SCSI drives, the msa1000 lowers the total cost of ownership and extends the customer’s
hardware investments into the future. The msa1000 can be remotely managed by using management tools such
as HP Insight Manager, Array Configuration Utility and the StorageWorks Fabric Switch Management Utility.
Support for Microsoft Windows Server 2003 has been added to the existing support for Windows 2000,
Windows NT, NetWare and Linux operating systems. In addition there is an alternative firmware that can replace
the standard firmware that provides support for Alpha servers in a Tru64 UNIX environment. Support for
OpenVMS will be released and announced at a later date Information about the support for these two operating
systems is included in a separate QuickSpec for the MSA1000 attached to Alpha-based servers. All notes in this
QuickSpec reference the Microsoft, NetWare, and Linux capabilities and options.
The msa1000 offers the following •
key features
•
Recent Enhancements
DA-11033
High performance controller(s) built on DAS to SAN {DtS} architecture for maximum investment protection
4U rackmount design combining both the controller and disk shelf
•
2 Gb Fibre Channel host connections
•
Optional embedded 8-port 2 Gb Fibre Channel Fabric Switch or 3-port 2 Gb Fibre Channel hub
•
Ultra3 SCSI connections to drives
•
Support for HP Ultra2, Ultra3, and Ultra320 Universal 1” Drives
•
Scaleable from 3 to 42 drives via HP StorageWorks 4200/4300 Enclosures
•
Support for 1 Gb and 2 Gb Fibre Channel fabrics
•
Compatible with ISV backup and restore software from Hewlett Packard, VERITAS and others
•
Availability of alternative firmware allowing support for Alpha servers in their own SAN environments running
Tru64 UNIX operating system. Refer to QuickSpecs for the MSA1000 specific for Tru64 UNIX for details.
•
Availability of an optional embedded 8-port Fibre Channel switch allowing greater inherent scalability and full
interoperability with thousands of external HP SAN switches.
•
Multiple clusters and/or single server concurrent access by Microsoft, NetWare and Linux OSes to an
individual msa1000.
•
Recently introduced 3-port embedded hub option offers the most cost-effective interconnect for a 2-node
cluster
•
Support for NetWare 5.1 & 6.0 operating systems
•
Support for Red Hat Professional 7.2, Red Hat Advanced Server 2.1, and SuSE 7.2.
•
Redundancy (if present) retained while expanding number of drives or enlarging LUNs
•
Ability to add an additional storage drive enclosure to a msa1000 without power cycling unit
•
Ability to add additional clusters to an existing msa1000 SAN without power-cycling the msa1000
•
Support for larger and/or faster drives allowing total capacity to scale to 6 TB
World Wide — Version 13 — July 23, 2003
1
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
MSA1000 Highlights
High Levels of Performance,
Scalability, and Functionality
•
•
•
•
•
•
•
DtS Architecture
(Direct Attach to SAN) Data
Migration
DA-11033
Performance – The msa1000 and its components have been designed using the latest industry standard 2
Gb interconnects and Fibre Channel technology. Performance tests indicate a data transmission rate of
over 30, 000 IOPS and bandwidth of up to 200 MB per second. (Single msa1000 Controller)
Modular Chassis – The modular design of the msa1000 cabinet supports up to fourteen 1″ Universal hard
drives, redundant controllers, 2 Gb embedded fabric switches or hubs, fans and power supplies in a 4U
rackmount cabinet.
Scalability – The msa1000 is easily expanded. The msa1000 cabinet scales to 2.0 TB using fourteen 146
GB, 1″ HP Universal hard drives. By simply adding additional StorageWorks 4200/4300 Enclosures (two
enclosures max), the msa1000 scales to 6.0 TB using forty-two 146 GB 1″ HP Universal hard drives – all
within 10U of rack space.
MSA SAN Switch 2/8 – The optional MSA SAN Switch 2/8, which can be installed within the msa1000
cabinet, offers 2 Gb full fabric performance at an attractive price. A second MSA SAN Switch 2/8 can be
installed for redundancy. There are seven pluggable ports available (four SFPs are included). The eight port
is directed internally to the controller.
MSA Hub 2/3 – The optional MSA Hub 2/3, which can be installed within the msa1000, offers 2 Gb
performance. With two ports accessible by the user, the MSA Hub 2/3 is the ideal interconnect for low-cost
2-node clustering or simply attaching two servers. A second MSA Hub 2/3 can be installed for redundancy.
This hub ships with two SFPs included. Not available for Linux with Secure Path environments. Not yet
available for Alpha server environments.
Hot Plug Expansion and Replacement Support – The msa1000 supports hot plug expansion and
replacement of hard drives, redundant controllers, fabric switches or hubs for simple, fast installation and
maintenance. Fans and power supplies are also hot plug replaceable.
Advanced Data Guarding (RAID ADG) Fault Tolerance – This is the highest level of fault tolerance. It
allocates two sets of parity data across drives and allows simultaneous write operations. This level of fault
tolerance can withstand two simultaneous drive failures without downtime or data loss.
DtS (Direct Attach to SAN) architecture is an exclusive msa1000 feature that provides a quick and easy way to
migrate stored data protected by most Smart Array controllers to an msa1000 storage system.
Data that is currently stored on 1″ Universal disk drives using newer HP Smart Array controllers, as well as data
on a ra4100 can easily be migrated to the msa1000. Simply remove the drives from the older systems and insert
them into the msa1000. All configuration information and data will be preserved allowing migration to be
completed in minutes, not hours or days. Refer to the msa1000 DtS Data Migration White Paper for a list of
compatible Smart Array controllers and further details.
World Wide — Version 13 — July 23, 2003
2
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
MSA1000 Highlights
Low Total Cost of Ownership
The modular and scalable design of the msa1000 provides an extremely flexibly platform. You can buy what you
need today and purchase additional capacity and performance as your data storage needs grow, instead of
making a large up-front investment. Additional drives, controllers, cache, fabric switches and storage enclosures
can easily be added, as your storage needs change.
•
Fabric Support for 1 Gb and 2 Gb Infrastructure – The msa1000 supports both 1 Gb and 2 Gb Fibre
Channel fabrics to ensure that your investment in 1 Gb infrastructure is protected.
•
Optional embedded interconnects – Both the MSA SAN Switch 2/8 and the MSA Hub 2/3 require no rack
space as they are installed in the msa1000’s chassis. This not only saves valuable rack space (up to 2U
saved) but also eliminates some of the cabling needed with external interconnects. The MSA SAN Switch
2/8 ships with 4 SFPs installed and the MSA Hub 2/3 ships with 2 SFPs.
•
Universal Hard Drive – Since the msa1000 supports HP Universal 1″ Ultra2, Ultra3, and Ultra320 drives,
your investment in SCSI technology is protected and cost is minimized as you add new drives. Sharing of a
common universal drive form factor between your servers and storage can significantly reduce needs for
hardware and spare inventory, and offer overall reduction in storage management and business costs.
•
Pre-Failure Warranty – Drives installed in an msa1000 and monitored under Insight Manager are supported
by a Pre-Failure (replacement) Warranty. NOTE: Pre-Failure Warranty allows for the replacement of
designated drives in an msa1000 before they actually fail when using Insight Manger on ProLiant servers.
NOTE: Some operating systems may not support all of these features.
•
Multi-platform Intel-based Server Support – The msa1000 offers Multi-platform Intel-based (x86) server
support to allow a broad range of Intel-based servers to take advantage of the msa1000’s scalability,
flexibility and connectivity. When used with a ProLiant server, the msa1000 also provides unparalleled
integration with Insight Manager, msa1000 Support CD and Pre-Failure Warranty support.
•
Alpha server support – The MSA1000 also supports Alpha-based servers operating in a Tru64 UNIX
environment. This support is enabled by replacing the controller firmware that comes standard with the
MSA1000. The alternative firmware is shipped with every MSA1000 and is also downloadable for free on the
MSA1000 web-site. Refer to the MSA1000 QuickSpec for Alpha servers for details.
•
Integrated Configuration and Management Tools – The msa1000 utilizes a standard, integrated set of
management and utility software. These tools consistently lower the cost of ownership by reducing training
and technical expertise necessary to install and maintain the MSA1000.
The msa1000 comes with/supports the following configuration and management tools:
Configuration
•
Array Configuration Utility (ACU). ACU is a browser-based disk
configuration utility that lets you view, set up, and configure the array
controllers and storage systems.
•
Command Line Interface (CLI)
Management/Health
•
Insight Manager (CIM)
•
Array Diagnostics Utility (ADU) This utility collects information about the
array controllers in the system and generates a list of potential problems it
has identified. It produces a report that can be saved to a diskette and
analyzed by support technicians to aid in problem resolution.
•
The msa1000 Support Software CD is a bootable media that enables a
ACU/ADU Bootable Utility
server to boot into a Linux shell and launch the ACU allowing the user to
configure the msa1000 storage or generate a diagnostic report without
requiring a pre-installed operating system or drivers.
Compatibility
DA-11033
Servers
World Wide — Version 13 — July 23, 2003
Supports most 32-bit ProLiant servers including DL320, DL320 G2, DL360 G2,
DL360 G3, DL380 G2, DL380 G3, DL560, DL580, DL580 G2, DL740, DL760,
DL760 G2, ML370 G2, ML370 G3, ML530 G2, ML570, and ML570 G2.
Certification of new ProLiant models, including –BL servers, is ongoing.
Supports most multi-vendor industry standard 32-bit Intel-based (x86) servers.
Also supports (with alternative controller firmware installed in place of the
standard firmware) Alpha servers running Tru64 UNIX.
3
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Models
HP StorageWorks Modular SAN
Array 1000
DA-11033
msa1000, with 256 MB cache
msa1000 Controller, with 256 MB cache
201723-B22
218231-B22
256 MB Cache Module upgrade for Controller
254786-B21
MSA Fibre Channel I/O Module
218960-B21
MSA Hub 2/3 (integrated) ships with 2 SFPs installed
286763-B21
MSA SAN Switch 2/8 (integrated) ships with 4 SFPs installed
288247-B21
FCA2101 Host Adapter (Microsoft)
245299-B21
FCA2210 Host Adapter (NetWare)
281540- B21
FCA2214 Host Adapter (Linux)
281541-B21
FCA2354 Host Adapter (Tru64 UNIX)
261329-B21
2 Gb SFP SW Transceiver Kit
221470-B21
HP StorageWorks Enclosure Model 4314R
190209-001
HP StorageWorks Dual bus Enclosure Model 4354R
190211-001
HP StorageWorks Secure Path v4 for Windows Workgroup Edition
213076-B23
HP StorageWorks Secure Path v3.0C for NetWare Workgroup Edition
222411-B22
HP StorageWorks Secure Path v3.0 for Linux Workgroup Edition
291536-B21
ProLiant Cluster HA/F100 for msa1000 for NT 4.0 and Windows 2000
(dual server, single path)
ProLiant Cluster HA/F200 for msa1000 for NT 4.0 and Windows 2000
(dual server, redundant path)
ProLiant Cluster HA/L100 LifeKeeper for Linux
252408-B23
World Wide — Version 13 — July 23, 2003
252409-B23
303523-B22
4
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
MSA1000 Components
With the following components, your storage capacity and performance can be scaled to new levels:
Modular SAN Array 1000
The 4U cabinet houses up to fourteen 1″ Universal hot pluggable Ultra2, Ultra3, and/or Ultra320 drives. Each
msa1000 includes the following standard components: (1) msa1000 Controller, (1) MSA Fibre Channel I/O
Module with a single SFP, dual hot pluggable fans/power supplies and power cables, (2) 3′ VHDCI to VHDCI
SCSI cables to connect expansion enclosures, documentation and a support software CD.
The modular design of the msa1000 makes it possible to add redundant controllers, redundant single port Fibre
Channel I/O Modules, 3-port hub, or embedded fabric switches and storage expansion enclosures. Additional
storage enclosures may be added without power cycling the MSA1000.
msa1000 Controller
The msa1000 Controller is an integrated RAID controller with an LCD/LED status display and 256 MB read/write
battery-backed cache (expandable to 512 MB per controller). One msa1000 Controller is included with the
msa1000; a redundant msa1000Controller is an option. Purchase of Secure Path software is a requirement if a
second controller is chosen.
•
Redundant controller support with mirrored cache
Key Features
msa1000 Controller
Management Features
Fault Tolerance
Fault Recovery
DA-11033
World Wide — Version 13 — July 23, 2003
•
Fabric, Private Loop & Public Loop Support
•
Auto Negotiated F, FL & L Port Login
•
RAID 0, 1, 1+0, 5 and ADG
•
2 Gb/1 Gb Frequency Agile
•
Primary & Secondary Inter-Controller Link (ICL)
•
Host based configuration via ACU
•
Optionally configurable with Command Line Interface (CLI)
•
Remote configuration and monitoring via ACU (offline and remote) & CIM
•
Selective Storage Presentation: allows multiple hosts to access a single
msa1000 storage system. Host access can be defined all the way down to
a logical volume level.
•
Online RAID Level Migration: allows for online post-configuration change
to RAID level without destroying data or volume information.
•
Online Capacity Expansion: lets you add storage to an operational
msa1000—reducing expensive server downtime.
•
Global Online Spare: reduces the risk of data loss by facilitating automatic
rebuilds after a drive failure.
Several fault tolerant configurations which keep data available and servers
running while drives are being replaced are supported including:
•
Advanced Data Guarding (RAID ADG): Allocates the equivalenct of two
parity drives across multiple drives and allows simultaneous write
operations.
•
Distributed Data Guarding (RAID 5): Allocates parity data across multiple
drives and allows simultaneous write operations.
•
Drive Mirroring (RAID 1, (1+0 Striped Mirroring)): Allocates half of the drive
array to data and the other half to mirrored data, providing two copies of
every file.
Minimizes downtime, reconstructs data, and facilitates a quick recovery from
drive failure:
•
Online Spares: If a failure occurs, recovery begins with an online spare
and data is reconstructed automatically. Multiple online spares can be
assigned per array and used across multiple arrays. It is also possible to
assign different online spares across different arrays.
•
Array Accelerator: Onboard, battery-backed cache memory protects data
in the event of a power failure. In the unlikely event of a controller failure,
the battery-backed cache will save critical user data for up to three days.
5
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
MSA1000 Components
MSA Fibre Channel I/O Module
Provides a single 2 Gb Fibre Channel connection per controller from the host side into the msa1000. The MSA
Fibre Channel I/O Module includes one 2 Gb, Short Wave, Small-Form-Factor-Pluggable Transceiver (SFP). A
second MSA Fibre Channel I/O Module can be installed for redundancy when a redundant controller is used.
MSA SAN Switch 2/8 (embedded) The new optional MSA SAN Switch 2/8 offers low price per port and full scalability, doing so while taking zero rack
space, even in a redundant configuration. This second generation integrated switch option offers the customer
more ports than our previous offering and is a full member of the HP SAN Switch family, assuring interoperability
from the smallest to the largest SAN configuration. The HP StorageWorks MSA SAN Switch 2/8 can be used by
the true entry-level customer looking for a very inexpensive switch based on cost per port. This same switch can
be attractive to the larger customer who must have the interoperability with their other external SAN switch
products from HP and especially appreciates the rack space saving characteristics.
The MSA SAN Switch 2/8 replaces the MSA Fabric Switch 6 option.
Key Features
•
eight 2 Gb ports: 1 to controller, 7 user accessible
•
product ships with 4 SFPs installed
•
2 more ports plus full cascade ability (previous model had 1 “hop”
restriction)
•
feature set common with SAN Switch product line (not –EL models)
•
no E-port restriction, accepts all optional software
•
interoperates with external SAN Switch 2 Gb switches
•
configuration and management methodology common with SAN
Switch product line, same methods as installed base of 30,000+ HP 1
and 2Gb SAN Switches
NOTE: The MSA SAN Switch 2/8 can be cascaded to a like switch in another
MSA1000 or to any external HP fabric switch in the “Infrastructure”
family. See the msa1000 Compatibility Matrix available at
http://www.hp.com/go/msa1000 for details.
MSA Hub 2/3 (embedded)
The HP StorageWorks MSA Hub 2/3 is a low-cost interconnect designed for clustering or low cost, high speed
attachment of two servers to the msa1000. The MSA Hub 2/3 is a 3-port Fibre Channel Arbitrated Loop hub that is
mounted on a blade that easily installs inside the msa1000 storage unit, saving valuable rack space. Two of these
hubs may be installed for redundancy within the msa1000. The MSA Hub 2/3 is not cascadable.
The hub presents the user with two SFP ports for simple direct attachment to two single or clustered servers
without having to purchase an external interconnect device. It offers the most cost-effective solution for a user to
enable a clustered server environment.
•
High Performance: supports msa1000 with a 2 Gb interconnect capable of 200 MB speed
•
Low Cost: supports the entry-level SAN array with the most cost effective option for 2-node clustering
•
Compact: imbeds in the msa1000, replacing the I/O module, saving valuable rack space
•
Complete: comes with two SW SFPs – no need for further investment
•
Not qualified in configurations where Secure Path is used in conjunction with Linux. Also not qualified with
Tru64 UNIX Alpha servers.
2 Gb Small Form Factor Pluggable 2 Gb Small-Form-Factor-Pluggable (SFP) SW Transceivers are industry standard connection devices, which hot
plug into 2 Gb infrastructure components such as 2 Gb Fabric Switches. HP StorageWorks 2 Gb SFP SW
(SFP) SW Transceiver Kit
Transceivers support distances up to 300 meters at 2 Gb and 500 meters at 1 Gb using multi-mode fiber optic
cable.
Multi-Mode Fibre Channel Cables Multi-Mode Fibre Channel cables provide a thin, flexible cabling solution that is immune to electromagnetic
interference. HP offers cables to connect the msa1000 to both 2 Gb and 1 Gb Fibre Channel infrastructures. LC
to LC cables are used when connecting the msa1000 to other 2 Gb Fibre Channel components because both
connections will utilize small form factor transceivers. LC to SC cables are used when connecting the msa1000 to
1 Gb Fibre Channel components. 1 Gb components use the larger GBIC style transceivers.
DA-11033
World Wide — Version 13 — July 23, 2003
6
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Software Components
The msa1000 utilizes a single, consistent set of utility software for storage and RAID management, setup, configuration and troubleshooting. This consistency
reduces the cost of ownership by reducing the training and technical expertise necessary to install and maintain your HP storage solution.
Array Configuration Utility
•
•
•
•
•
Provides a graphical view of HP drive array configurations
Easy to use Wizards for configuration
ACU supports on-line configuration
Web Based ACU-XE supports On-Line, Remote Web Based and Off-line configuration
Runs online on Microsoft Windows NT 4.0 and Microsoft Windows 2000
Selective Storage Presentation
(SSP)
•
•
•
Built-in to msa1000 Controller firmware and controlled via ACU
Allows setting of access rights to the msa1000 storage by hosts
Access control can be set up to a logical volume level using the Array Controller Utility
Insight Manager
•
•
•
Powerful storage, server and server option management tool
Monitor storage from a remote central location
Browser based CIM provides full access from anywhere on the Intranet, eliminating the need for a dedicated
Insight Manager management console
HP OpenView storage virtual
replicator, one license ships
standard
Virtual Replicator combines a rich set of innovative capabilities that enhances and simplifies storage management
for Windows NT and Windows 2000 environments. Through virtualization, online volume growth, snapshot and
management features, the software complements the standard capabilities within the operating system. HP
OpenView storage Virtual Replicator provides virtualization enabling storage consolidation and capacity
provisioning for flexible, simplified storage management on Windows based servers. An OpenView Virtual
Replicator CD with a single system license and ten 60-day evaluation licenses are included with the msa1000.
Additional licenses of Virtual Replicator are available through your local HP sales office.
Key Features
•
Support for NT and Windows 2000
•
Virtualization – Allows companies to respond quickly to rapidly changing
storage capacity requirements. With storage virtualization, multiple storage
arrays can be consolidated into a pool of disk space for individual or
clustered systems to use. Multiple virtual disks, up to 2 terabyte in size,
can be created from a pool for users and their applications. System
administrators can tailor disk space to specific requirements. Existing
storage units with production data can be imported into a pool, the data
partition being preserved as a virtual disk and unused capacity added to the
pool.
•
Online volume growth – Enables easy, non-disruptive growth for
Windows 2000 with zero downtime. Online Volume Growth allows a
system administrator to grow an existing volume on an HP OpenView
Virtual Replicator virtual disk and also a Windows 2000 basic disk. The
system will remain online, and the data on the volume will remain intact.
•
Snapshots – Instant, point-in-time snapshots for backup, online restore,
testing or data mining. Enable the instant creation of multipurpose virtual
replicas of production data without the requirement of a physical copy
Snapshots function identically to ordinary physical disks, with both read and
write capability. Whenever a quick copy of production data is needed,
snapshots can be used with minimal disruption to running applications. For
example, the snapshot can be the source for backup using standard
backup tools. Snapshots can remain online for restore operations, testing,
and data mining.
•
Management – Simplifies management tasks through easy-to-use
interfaces using Microsoft Management Console or a command line.
Interactive wizards are available to guide the administrator through all
management tasks and create automatic schedules of operations for
investment protection and to reduce staff retraining.
•
Fully cluster-aware
•
Command line interface for scripting
•
Scheduling wizards remove the guesswork from repetitive operations
Please refer to the Optional Software section of this document or visit
http://www.hp.com/go/msa1000 for additional details.
DA-11033
World Wide — Version 13 — July 23, 2003
7
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Software Components
OS Support
•
Microsoft Windows Server 2003
•
Microsoft Windows 2000 Server and Advanced Server (sp3)
•
Microsoft Windows NT 4.0 Server and Enterprise Edition (sp6a)
•
NetWare 5.1 and 6
•
Red Hat Linux Personal/ Professional 7.2 ( LifeKeeper clustering available from SteelEye, not HP)
•
Red Hat Linux Advanced Server 2.1
•
SuSE Linux SLES 7
•
Tru64 UNIX supported with alternative firmware (included in box)
Please refer to compatibility matrix at http://www.hp.com/go/msa1000 for complete configuration support.
Software Certifications
•
Microsoft Cluster Server Certification
•
Hewlett Packard Data Protector
•
VERITAS Backup Exec and NetBackup
•
Legato NetWorker for Windows
•
Computer Associates BrightStor Enterprise Backup
Please refer to compatibility matrix at http://www.hp.com/go/msa1000 for complete configuration support
DA-11033
World Wide — Version 13 — July 23, 2003
8
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Optional Software
Secure Path
Secure Path is a family of high availability multi-pathing software products providing continuous data access from
the HP RAID Array to host servers running the Windows 2000, Windows NT, Linux and NetWare operating
systems.
Redundant hardware, advanced RAID technology and Secure Path's automated failover capability are used to
enhance fault tolerance and availability. Secure Path effectively eliminates controllers, disk drives, interconnect
hardware and host bus adapters as single points of failure in the storage subsystem.
The attachment of non-Secure Path (single HBA) servers to an MSA1000 with dual controllers that has servers
with Secure Path (dual HBA) attached is supported where the operating systems are Microsoft or Novell. Users
must realize that in event of a controller fail-over (failure of active controller) the single path servers will lose
access to their data on the MSA1000.
NOTE: If Secure Path for Linux is used on any node or cluster attached to an MSA1000, all nodes must also have
Secure Path installed, regardless of operating systems. In addition, Secure Path for Windows is not supported in
conjunction with use of the MSA Hub 2/3.
NOTE: refer to http://www.hp.com/go/securepath for the latest Secure Path parameters.
Key Features
•
Maintains connections to storage
•
Monitors I/O paths and alerts on significant events
Used in
•
Stand alone Configurations
•
Cluster configurations
•
SAN configurations
msa1000 clustering
Clustering is rapidly gaining in popularity as users desire a high level of data availability. Many of the old cluster
restrictions that were the product of both hardware and operating systems have been overcome. While there still
remain configuration limits, the result is a new high degree of flexibility both in number of clusters, mixing clusters
with single nodes, and the integration of dissimilar operating systems.
The user may attach up to a maximum of three Microsoft clusters to a single msa1000. This is only a limit to the
number of Microsoft clusters, not a limit to the number of devices that may share concurrent access. For example
you may mix three Microsoft (Windows Server 2003, Windows 2000, or Windows NT) clusters and other individual
servers, even doing so in a heterogeneous server operating system environment. Windows Server 2003 allows a
single cluster of up to eight nodes,
Single-path (single controller, non-Secure Path) NetWare clustering has been successfully tested up to a 12-node
cluster. NetWare clusters employing Secure Path (dual controller, dual HBAs) are limited to two nodes. Multiple
NetWare clusters (and single servers) may have concurrent access with no limitation inherent to the msa1000.
Likewise up to a 16-node Linux cluster (single controller, non-Secure Path) utilizing LifeKeeper clustering software
has been tested and is supported. Presently a Linux/Secure Path configuration is limited to a two node cluster.
Refer to http://www.hp.com/go/securepath for any restriction on Linux with Secure Path.
The msa1000 has the ability to be configured with thirty-two LUNs. This limitation boundary establishes the
maximum number of nodes that can be connected to an msa1000. Best practices would dictate no more than
sixteen servers accessing a single msa1000. More commonly, users have had an average of five to eight nodes.
This can be any combination of hosts or clusters with different operating systems while holding fast to the
guidelines and limits described in the above paragraphs. Performance within these guidelines is heavily
dependent on the actual number of end users and types of applications being employed.
For more information, click on the link: http://.www.hp.com/enterprise/highavailability/index.html
HP ProLiant Cluster HA/F200 for
msa1000 (Microsoft)
The ProLiant Cluster HA/F200 for msa1000 uses HP’s industry-leading ProLiant servers, HP StorageWorks
Modular SAN Array 1000, Ethernet server to server interconnect, and HP’s industry-leading installation and
systems management utilities.
The ProLiant Cluster HA/F200 for msa1000 kit delivers a higher level of availability in cluster environments by
enabling multi-path Fibre Channel connections. Secure Path management software, included with the kit,
features support for a redundant Fibre Channel infrastructure (two paths through the Fibre Channel hub or Fabric
Switch) utilizing dual Host Bus Adapters in each server connected to one or more msa1000 storage subsystems,
each with dual RAID controllers.
Tested configurations:
•
Up to four (4) heterogeneous/homogeneous clusters per SAN (e.g., 2-node, 4-node, 8-node depending on
OS version limitations)
•
Up to ten (10) MSA1000s per SAN
•
Heterogeneous OS's (NT, W2K, W2K3, NW, Linux); cluster size is OS dependent (e.g., 2-node for NT, W2K,
NW, & Linux)
•
Cluster nodes can attach to up to two (2) MSA1000s
•
Available now for Windows Server 2003, Windows 2000 and Windows NT.
HP ProLiant Cluster HA/F200 for msa1000 (Microsoft)
252409-B23
DA-11033
World Wide — Version 13 — July 23, 2003
9
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Optional Software
HP ProLiant Cluster HA/F100 for
msa1000 (Microsoft)
The ProLiant Cluster HA/F100 for msa1000 is a robust, integrated cluster solution providing high availability for
applications and data in business-critical environments. An ideal platform for business-critical databases, large
business applications, email or file/print services, the ProLiant Cluster HA/F100 for msa1000 offers Fibre Channelbased clustering at a fraction of the cost of proprietary cluster solutions.
The ProLiant Cluster HA/F100 for msa1000 exploits HP’s industry-leading servers, HP StorageWorks Modular
SAN Array 1000, Ethernet interconnect and HP’s leading installation and systems management utilities. Cluster
Management is provided by Microsoft's Cluster Server software, included as part of Microsoft NT Server 4.0
Enterprise Edition, and Microsoft Windows 2000 Advanced Server.
Available now for Windows Server 2003, Windows 2000 and Windows NT.
HP ProLiant Cluster HA/F100 for msa1000 (Microsoft)
252408-B23
HP ProLiant Cluster HA/L100
LifeKeeper for Linux
The HP ProLiant Cluster HA/L100 Cluster Kit provides for a one-stop product to facilitate the implementation of a
two to 16 server node Linux based high availability cluster solution to protect applications and data in a businesscritical environment. The HA/L100 supports HP ProLiant servers in mix and match configurations from the ML330
to the DL760 and the ISS Smart Array Cluster Storage Systems as well as the ra4100, msa1000, and ma8000
shared fibre storage subsystems. The kit includes a Cluster Installation Guide for ProLiant Servers, storage and
the two Linux distributions supported: Red Hat and SuSE. The kit also includes SteelEye Technology’s LifeKeeper
for Linux Version 4.1.1 Core cluster software including LifeKeeper Installation and Documentation CD’s. The HP
ProLiant Cluster HA/L100 supports the industry-standard Linux Distributions from Red Hat and SuSE for base
operating systems support and SteelEye LifeKeeper for Linux Version 4.1.1 Core, included in the HA/L100 cluster
kit as 30 day evaluation software which can be permanently licensed through SteelEye Technology or one of their
resellers or partners.
NOTE: While Secure Path for Linux has been announced, you must refer to http://www.hp.com/go/securepath for
the latest Secure Path for Linux parameters.
HP ProLiant Cluster HA/L100 LifeKeeper for Linux
303523-B21
HP ProLiant Clusters for NetWare HP supports a broad range of solutions for NetWare Cluster services including configurations featuring the
msa1000 and optionally with HP StorageWorks Secure Path. These solutions provide high availability and
maximum resource utilization for NetWare environments from small file sharing implementations to enterprise
business computing. Single-path (single controller, non-Secure Path) NetWare clusters of up to 12-nodes have
been successfully tested. Presently 2-node NetWare clusters with Secure Path have been tested and approved
with larger NetWare cluster testing planned. Multiple NetWare clusters are allowed.
NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path for NetWare parameters
HP ProLiant Parallel Database
Clusters for Oracle on msa1000
DA-11033
The HP Parallel Database Clusters (PDC) for Windows and Linux provide the industry’s leading platform for
deployment of Oracle 9i Real Application Clusters. The PDC is a multi node (up to six in Microsoft environments
and up to four with Linux)) shared-storage clustering environment that enables industry standard Windows and
Linux platforms to deliver performance previously limited to very large SMP (16 to 32 processor) environments.
Every server node in the cluster has concurrent read-write access to the common shared database residing on
the msa1000 storage SAN. The multi-node architecture is inherently highly available, loss of any single node
results in some degradation of performance but the database remains active and accessible. When optimally
integrated with Oracle load balancing and transparent application reconnect features, clients are completely
insulated from the loss of a server resource or an Oracle instance failure on a node. To complement the high
availability of the server cluster in a Windows environment, the Parallel Database Cluster integrates HP
StorageWorks Secure Path for fully redundant access to the database in the even of any failure in SAN
connectivity. Secure Path for Linux will be available at a later date. Combined, the Oracle clustering technology
and HP platform technology deliver cost effective and highly available enterprise solutions for database
applications.
For more specific information concerning configuration, interconnect options, and dual path software refer to the
HP/Oracle site at http://h18000.www1.hp.com/solutions/enterprise/highavailability/oracle/index.html
World Wide — Version 13 — July 23, 2003
10
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Service & Support, HP Care Pack and Warranty Information
Storage Service Packages
The Storage Services Packaging takes the existing storage product along with the existing services and creates a
package of the storage hardware and appropriate services. The increased level of support provides for a higher
level of storage system availability for the customer. The package includes 24x7 support with a 4-hour response
for 3 years as well as installation and startup service.
Warranty
Three-year Limited Warranty for msa1000s, Fibre Channel Cables and SFP Transceivers; 3 years parts
exchange; 1 year labor; 1 year on-site; next business day response. Options for the msa1000 carry their own
warranty. Refer to HP's Limited Warranty Statement for further details.
Service & Support, HP Care Pack Software Product Services
and Warranty Information
Hardware Product Services
Installation and Startup
Services
Warranty Upgrade Options
DA-11033
World Wide — Version 13 — July 23, 2003
•
HP warrants only that the Software media will be free of physical defects for
a period of ninety (90) days from delivery.
•
Upgrades to the 90 day media defect warranty are available as HP Care
Pack services. These services are available to upgrade the warranty to (1
or 3) full year of 9 hours by 5 days (or 24x7) software advisory and
remedial software telephone support, new version license rights, and media
and documentation distribution service.
•
Installation services
•
On-site maintenance (includes warranty support)
•
Response time upgrades during the warranty period
•
Post-warranty coverage
•
RAID setup and performance consulting via statement of work
•
Migration service consulting via statement of work
The Installation and Startup Service package provides installation and
configuration of HP StorageWorks products. Major categories of work could
include:
•
Pre-installation consulting and planning
•
Hardware installation, configuration and verification
•
RAID array configuration and initialization
•
Installation, configuration and verification of StorageWorks software
•
Service tools installed, configured and verified
•
Customer orientation
•
Response – Upgrade on-site response from next business day to same day
4 hours
•
Coverage – Extend hours of coverage from 9 hours x 5 days to 24 hours x
7 days
•
Duration – Select duration of coverage for a period of 1, 3, or 5 years
11
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Service & Support, HP Care Pack and Warranty Information
HP Care Pack Information
Sample part numbers :
DA-11033
9x5, Next Business Day, On-Site Coverage, 3 years
FM-FCXHW-36
103840-002
9x5, 4-Hour Response, On-Site Coverage, 3 years
FM-FC4HR-36
402165-002
24x7, 4-Hour Response, On-Site Coverage, 3 years
FM-FC724-36
402164-002
9x5, Next Business Day, On-Site Coverage, 5 years
FM-FCXHW-60
170183-002
9x5, 4-Hour Response, On-Site Coverage, 5 years
FM-FC4HR-60
170185-002
24x7, 4-Hour Response, On-Site Coverage, 5 years
FM-FC724-60
170187-002
Hardware Installation
FM-FCINS-IN
402162-002
•
HP Care Pack is defined as an upgrade to the product warranty attribute, available for a specific duration
and hours of coverage.
•
HP Care Pack is not available for less than the product’s warranty duration.
•
HP Care Pack is available for sale anytime during the warranty period for most products, but the
commencement date will be the same as the Warranty Start Date (delivery date to end user customer).
Proof of purchase may be required.
•
HP Care Pack services are prepaid.
NOTE: For additional HP Care Pack (hardware & software) information on European and other countries, as well
as orderable part numbers, please refer to the URL listed below:
http://h18005.www1.hp.com/services/carepaq/index.html
World Wide — Version 13 — July 23, 2003
12
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Configuration Information
STEP 1 – ORDER REQUIRED ITEMS
HP StorageWorks Modular SAN Array 1000
Includes
DA-11033
World Wide — Version 13 — July 23, 2003
201723-B22
•
(1) msa1000 Controller with 256 MB cache
•
(1) MSA Fibre Channel I/O Module with 2 Gb SFP SW Transceiver
•
Redundant Hot Pluggable Power Supply/blower assemblies
•
Universal Rackmounting Kit
•
msa1000 Support CD & Documentation
•
Serial cable
•
(2) Power cables
•
(2) 3-ft VHDCI to VHDCI SCSI cables
NOTE: Fibre Channel cables are ordered separately.
13
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Configuration Information
STEP 2 – CHOOSE OPTIONAL NON-REDUNDANT MSA1000 SYSTEM OPTIONS
MSA SAN Switch 2/8 (integrated) (Includes four 2Gb SFPs)
MSA Hub 2/3 (integrated) (Includes two 2 Gb SFP transceivers)
NOTE: The MSA SAN Switch 2/8 has a total of eight Fibre Channel ports. There are
seven ports accessible by the user and the eighth is internal to the controller.
Four SFPs are shipped installed in the Switch.
The MSA Hub 2/3 has two external Fibre Channel ports, both of which already
have 2 Gb transceivers installed. Not supported with Linux/Secure Path, Tru64
UNIX, at this time.
DA-11033
World Wide — Version 13 — July 23, 2003
288247-B21
286763-B21
14
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Configuration Information
STEP 3 – CHOOSE REDUNDANT MSA1000 SYSTEM OPTIONS
Redundant Configuration
msa1000 Controller
218231-B22
256 MB Cache Modules for Controller (one additional for each controller)
254786-B21
NOTE: Redundant configurations require two Host Adapters per server, an additional
controller and I/O, a MSA SAN Switch 2/8 or a MSA Hub 2/3 (for Windows or
NetWare), and Secure Path software for each server. For Microsoft ProLiant
Clusters, Secure Path software can be substituted with the ProLiant Clusters
HA/F200 kit.
Mixing of the MSA Fibre Channel I/O Modular and the MSA SAN Switch 2/8 or
the MSA Hub 2/3 is not supported. When configuring the msa1000 for
redundant controllers use either two MSA Fibre Channel I/O Modules, two MSA
Hub 2/3s, or two MSA SAN Switch 2/8s.
MSA Fibre Channel I/O Module (Includes 2 Gb SFP transceiver)
MSA SAN Switch 2/8 (integrated) (Includes four 2Gb SFP transceivers)
MSA Hub 2/3 (integrated) (Includes two 2Gb SFP transceivers)
DA-11033
World Wide — Version 13 — July 23, 2003
218960-B21
288247-B21
286763-B21
15
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Configuration Information
STEP 4 – CHOOSE SUPPORTED OPTIONS F OR 2 GB OR 1 GB INFRASTRUCTURE
2 Gb Fibre Channel Transceiver
(SFP)
2 Gb SFP SW Transceiver Kit
221470-B21
2 Gb Fibre Channel Fabric
“Infrastructure” family of
switches
NOTE: “Infrastructure” switches above are interoperable only with HP StorageWorks
MSA SAN Switch 2/8, SAN Switch 2/8EL, 2/16, 2/32 core 2/64 products and all
Power Pak models. They are also interoperable with designated discontinued
1Gb SAN Switch models.
HP StorageWorks core 2/64 PowerPak
332178-B21
HP StorageWorks core 2/64
254508-B21
HP StorageWorks SAN Switch 2/32 Power Pak
333764-B21
HP StorageWorks SAN Switch 2/32
240603-B21
HP StorageWorks SAN Switch 2/16 Power Pak
322119-B21
HP StorageWorks SAN Switch 2/16
322118-B21
2 Gb Fibre Channel Fabric “High
Availability” family of switches
2 Gb Fibre Channel Integrated
Hub
DA-11033
HP StorageWorks SAN Switch 2/16-EL
283056-B21
HP StorageWorks SAN Switch 2/8 Power Pak
322121-B21
HP StorageWorks SAN Switch 2/8-EL
322120-B21
HP StorageWorks MSA SAN Switch 2/8 (Includes four 2Gb SFP transceivers)
288247-B21
Fabric Watch for 8 and 16 port switches
324504-B21
ISL Trunking kit for 8 and 16 port switches
324506-B21
Advanced Performance Monitor for 8 and 16 port switches
324507-B21
Quick Loop for 8 and 16 port switches
324508-B21
Remote Switch for 8 and 16 port switches
325891-B21
Extended Fabric for 8 and 16 port switches
324505-B21
HP StorageWorks Power Pak Bundle for 2Gb/s Brocade Based 8 and 16 port
Switches(Trunking, Perf Monitor, remote switch, fabric watch, extended fabric)
325892-B21
HP Storageworks 2/8-EL Upgrade license
325888-B21
Optional Rack mount kit for SAN Switch 2/8-EL and SAN Switch 2/16
331148-B21
Remote Switch for HP StorageWorks 2/64
330883-B21
ISL trunking for HP StorageWorks 2/64
325887-B21
Extended fabric for HP StorageWorks 2/64
325886-B21
NOTE: “High Availability” switches above are interoperable only with HP StorageWorks
Director 2/140. Director 2/64, Edge Switch 2/32, Edge Switch 2/24, and the
discontinued Edge Switch 2/16 products.
HP StorageWorks Director 2/140 (64-ports active)
HP StorageWorks director 2/64
316094-B21
286809-B21
HP StorageWorks edge switch 2/32 (16 active ports)
286810-B21
8-FlexPort upgrade for edge 2/32
302660-B21
HP StorageWorks Edge switch 2/24 (8 ports active)
316095-B21
8-FlexPort upgrade for edge 2/24
316096--B21
MSA Hub 2/3 (integrated option, comes complete with two SFPs)
Not for use with Linux/Secure Path configurations, Tru64 UNIX.
286763-B21
World Wide — Version 13 — July 23, 2003
16
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Configuration Information
S T E P 4 – C H O O S E S U P P O R T E D O P T I O N S F O R 2 G B O R 1 G B I N F R A S T R U C T U R E (continued)
2 Gb Fibre Channel HBAs
Fibre Channel Cables for 2 Gb
Infrastructure
Fibre Channel Cables for 1 Gb
Fabric Switches and Hub
STEP 5 –
Hard Drives
FCA2101 Host Adapter (Microsoft OS)
245299-B21
FCA2210 Host Adapter (NetWare OS)
281540-B21
FCA2214 Host Adapter (Linux OS)
281541-B21
FCA2354 Host Adapter (Tru64 UNIX)
261329-B21
Use 2 Gb Fibre Channel cables when connecting the MSA Fibre Channel I/O Module or
the MSA SAN Switch 2/8 to FCA2101 HBA(s)
2 m LC-LC Multi-Mode Fibre Channel Cable
221692-B21
5 m LC-LC Multi-Mode Fibre Channel Cable
221692-B22
15 m LC-LC Multi-Mode Fibre Channel Cable
221692-B23
30 m LC-LC Multi-Mode Fibre Channel Cable
221692-B26
50 m LC-LC Multi-Mode Fibre Channel Cable
221692-B27
Use 1 Gb Fibre Channel cables when connecting the MSA Fibre Channel I/O Module
and FCA2101 HBA(s) to 1 Gb fabric switches or hubs.
2 m LC-SC Multi-Mode Fibre Channel Cable
221691-B21
5 m LC-SC Multi-Mode Fibre Channel Cable
221691-B22
15 m LC-SC Multi-Mode Fibre Channel Cable
221691-B23
30 m LC-SC Multi-Mode Fibre Channel Cable
221691-B26
50 m LC-SC Multi-Mode Fibre Channel Cable
221691-B27
CHOOSE HARD DRIVES & STORAGEWORKS ENCLOSURES
36.4 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
286713-B22
72.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
286714-B22
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
286716-B22
18.2 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″)
286775-B22
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″)
286776-B22
72.8 GB Pluggable Ultra320 Universal Hard Drive, 15,000 rpm (1″)
*NOTE: All Ultra320 Universal Hard Drives are backward compatible to U2 or U3
speeds.
286778-B22
NOTE: For complete compatibility information, refer to the HP SCSI Hard Drive
Compatibility table located at http://www.hp.com/go/msa1000
DA-11033
World Wide — Version 13 — July 23, 2003
17
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Configuration Information
S T E P 5 – C H O O S E H A R D D R I V E S & S T O R A G E W O R K S E N C L O S U R E S (continued)
StorageWorks Enclosures
The msa1000 cabinet holds fourteen 1” Universal Drives. Add one StorageWorks
Enclosure to increase capacity up to 28 drives. Add two HP StorageWorks Enclosures
to increase capacity up to the maximum of 42 drives.
HP StorageWorks Enclosure Model 4314R (Maximum of two can be connected to the
msa1000)
HP StorageWorks Enclosure Model 4314R (Maximum of two can be connected to the
msa1000) (Int’l)
HP StorageWorks Enclosure Model 4314R (Maximum of two can be connected to the
msa1000) (Japan)
HP StorageWorks Enclosure Model 4354R (Maximum of one can be connected to the
msa1000)
HP StorageWorks Enclosure Model 4354R (Maximum of one can be connected to the
msa1000) (Int’l)
HP StorageWorks Enclosure Model 4354R (Maximum of one can be connected to the
msa1000) (Japan)
190209-001
190209-B31
190209-291
190211-001
190211-B31
190211-291
STEP 6 – CHOOSE RACK OPTIONS
9142 Rack
120663-B21, -B22, -B23
9122 Rack
120665-B21, -B22, -B23
10647 (47U) rack
245160-B21, -B23
10642 (42U) rack
245161-B21, -B22, -B23
10636 (36U) rack
245162-B21, -B22, -B23
10622 (22U) rack
245163-B21, -B22, -B23
CONFIGURATION EXAMPLES
Quantity
1
1
2
4
4
1
14
Quantity
1
1
2
2
8
8
4
2
42
DA-11033
Two Node Redundant Cluster Solution (Intel based servers)
Description
HP StorageWorks Modular SAN Array 1000
additional msa1000 Controller
MSA Hub 2/3 (not available for Linux with Secure Path environments)
Host Adapter (appropriate model for operating system)
2 m LC-LC Multi-Mode Fibre Channel Cable
ProLiant Cluster HA/F200 for msa1000 (includes Secure Path for two servers)
36.4 GB Pluggable Ultra320 Universal Hard Drive, 15K
4 Host, 6TB, Redundant SAN Solution (Intel based servers)
Description
HP StorageWorks Modular SAN Array 1000
additional msa1000 Controller
256 MB Cache Modules for Controller (one additional for each controller)
MSA SAN Switch 2/8 (Includes four 2Gb SFP transceivers)
Host Adapter (appropriate model for operating system)
2 m LC-LC Multi-Mode Fibre Channel Cable
Secure Path Workgroup Edition (1 license per server), appropriate for operating
system
StorageWorks Enclosure Model 4314R
146.8 GB Pluggable Ultra320 Universal Hard Drive, 10,000 rpm (1″)
World Wide — Version 13 — July 23, 2003
Part Number
201723-B22
218231-B22
286763-B21
221692-B21
252409-B22
286776-B21
Part Number
201723-B22
218231-B22
254786-B21
288247-B21
221692-B21
190209-001
286716-B22
18
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Related Options
SANworks Virtual Replicator v4.0 1 license
3 licenses
(Microsoft operating systems)
5 licenses
10 licenses
25 licenses
50 licenses
Base Media and Documentation Kit (license required)
Secure Path V3.0C for NetWare
Workgroup Edition
Secure Path v3.0C for NetWare Workgroup Edition one license
Secure Path v3.0C for NetWare Workgroup Edition five licenses
Secure Path v3.0C for NetWare Workgroup Edition 10 licenses
Secure Path v3.0C for NetWare Workgroup Edition 25 licenses
Secure Path v3.0C for NetWare Workgroup Edition 50 licenses
NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path
parameters for NetWare.
Secure Pathv4.0B for Windows
Workgroup Edition
(including Windows Server
2003/32bit)
(Package includes separate programs for both the msa1000 and the ra4000 and
ra41000 solutions.)
Secure Path v4.0B for Windows Workgroup one license
Secure Path v4.0B for Windows Workgroup Edition five licenses
Secure Path v4.0B for Windows Workgroup Edition 10 licenses
Secure Path v4.0B for Windows Workgroup Edition 25 licenses
Secure Path v4.0B for Windows Workgroup Edition 50 licenses
Secure Path v4.0B for Windows Workgroup Edition Upgrade License
Secure Path v4.0B for Windows Workgroup Edition for ProLiant BL line 8 licenses
(MSA1000 support for –BL servers coming mid-summer)
NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path
parameters for Windows.
Secure Pathv3.0 for Linux
Workgroup Edition
Secure Path v3.0 for Linux Workgroup Edition one license
Secure Path v3.0 for Linux Workgroup Edition five licenses
Secure Path v3.0 for Linux Workgroup Edition 10 licenses
Secure Path v3.0 for Linux Workgroup Edition 25 licenses
Secure Path v3.0 for Linux Workgroup Edition 50 licenses
NOTE: Refer to http://www.hp.com/go/securepath for the latest Secure Path
parameters for Linux.
Backup and Restore Software
261770-B22
266236-B22
261775-B22
261771-B22
261772-B22
261773-B22
261769-B24
222411-B22
231324-B22
231325-B22
231326-B22
231327-B22
213076-B25
231316-B25
231317-B25
231318-B25
231319-B25
261715-B23
325634-B22
291536-B21
291537-B21
291538-B21
291539-B21
291540-B21
VERITAS NetBackup for Windows v4.5
VERITAS Backup Exec for Windows v8.6
HP Data Protector v5
Computer Associates BrightStor Enterprise Backup v10.0
See Implementation Blueprint for configuration and installation instructions for all
backup and restore software.
ProLiant Cluster for MSA1000
(not yet available for Windows
Server 2003)
ProLiant Cluster HA/F100 for msa1000 v2
ProLiant Cluster HA/F100 for msa1000 v2 (Japan)
ProLiant Cluster HA/F200 for msa1000 v2
ProLiant Cluster HA/F200 for msa1000 v2 (Japan)
DA-11033
World Wide — Version 13 — July 23, 2003
252408-B22
252408-292
252409-B22
252409-292
19
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Technical Specifications
Modular SAN Array 1000
201723-B22
LED Indicators on Front (3)
Power
Fault detected in one or more sub-systems
Fault in Enclosure Management
LED Indicators for Drive
Modules (3)
Drive Access (center)
Online (left)
Drive Failure (right)
LED Indicators on Rear Panel Power Supply/Blower Assembly Fault (1)
(4)
EMU (3) Power, A bus, B bus
Interface
Ultra3 SCSI to Hard Drives
2 Gb Fibre Channel to Hosts
Maximum Number of Drives
Temperature Range
Fourteen, 1-inch HP Ultra2, Ultra3 or Ultra 320 Universal Hard Drives (msa1000
Cabinet); expandable to 42 using two additional HP StorageWorks 4200/4300
Enclosures
Operating
50° to 95°F/10° to 35°C
Shipping
–22° to 122°F/–30° to 50°C
NOTE: Derated 1°C per 1,000 feet of elevation to 10,000 ft.
Relative Humidity
Input Power Requirements
10% to 90%
Non-operating
Rated Input Voltage
Rated Input Frequency
Rated Input Current
Up to 95%
100 to 240 VAC
50 to 60 Hz
6 A Max
Input Power (max)
549 W*
Heat Dissipation (max)
1876 Btu/hr*
msa1000 Cabinet
NOTE: Input Power and Heat Dissipation specifications are maximum values and
apply to worst-case conditions at full rated power supply load. The
power/heat dissipation for your installation will vary depending on the
equipment configuration.
4U Rack Form Factor
Shipping Packaging
User Interface
DA-11033
Operating
Dimensions (H x W x D)
6.9 x 19 x 20.5 in/17.5 x 48.3 x 52.1 cm
Weight
Net 55 to 85 lb/24.95 to 38.56 kg
Dimensions (L x W x D)
28.5 x 14.81 x 33.13 in/72.4 x 37.6 x 84.1 cm
Weight (Gross)
75 to 105 lb/34.02 to 47.63 kg
Electrical Interface
Controller display with Status Indicators (2) and push buttons (4) on front of
controller
LVD (Low Voltage Differential)
Protocol Support
Wide Ultra3 SCSI
SCSI Ports
4-channel: 2 internal, 2 external
Drives Supported
up to 42 drives
Maximum Capacity
6TB (42 drives x 146GB)
Logical Drives (LUN)
up to 32 Logical Drives
Maximum Logical Drive size
2.0TB
World Wide — Version 13 — July 23, 2003
20
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Technical Specifications
Modular SAN Array 1000
Controller
218231-B22
User Interface
Controller Display with Status Indicators (2) and Push Buttons (4)
Status Indicators on front of Controller (16)
Electrical Interface
LVD (Low Voltage Differential)
Protocol Support
Wide Ultra3 SCSI (160 MB/s per channel)
SCSI Ports
4-channel: 2 external/2 Internal
Drives Supported
Up to 42 drives
Maximum Capacity
6.0 TB (42 drives x 146 GB)
Logical Drives
Up to 32 logical drives
RAID Support
RAID ADG (Advanced Data Guarding)
RAID 5 (Distributed Data Guarding)
RAID 1+0 (Striping & Mirroring)
RAID 0 (Striping)
Cache Memory
Up to 512 MB Read/Write (256 MB modules). If redundant controllers are used
they must have equally configured cache.
ECC protection, battery-backed, and removable
Standard as of November 19, 2002: 256 MB cache memory (single module)
Cache Batteries
Up to three days of redundant battery life, removable for easy replacement
Upgradeable Firmware
2 MB flashable ROM
Disk Drive and Enclosure
Protocol Support
HP Ultra 320, Ultra3, and Ultra2 SCSI 1-inch Universal drives
Packaging
Dimensions (L x W x D)
17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm
Weight (Gross)
6 lb/2.72 kg
Modular SAN Array Fibre Channel Connector Type
I/O Module
Number of Fibre Channel
218960-B21
Ports
DA-11033
LC
One 2 Gb Fibre Channel Port using removable Small-Form-Factor-Pluggable
Transceiver (SFP)
Bandwidth
200 MB/s
Operation Modes
Fibre Channel Class 2 and 3 connectionless service
Protocols Supported
Fibre Channel
Packaging
Dimensions (L x W x D)
17 x 12.5 x 7.75 in/43.2 x 31.75 x 19.7 cm
Weight (Gross)
6 lb/2.72 kg
World Wide — Version 13 — July 23, 2003
21
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Technical Specifications
MSA SAN Switch 2/8
288247-B21
performance
2.125 Gbit/sec line speed, full duplex ;1.063 Gbit/sec line speed, full duplex;
Auto-sensing of 1 Gbit/sec and 2 Gbit/sec port speeds; optionally programmable
to fixed port speed; Speed matching between 1 Gbit/sec and 2 Gbit/sec ports
Aggregate bandwidth 64 Gbit/sec end to end Fabric latency <2.1 µsec with no
contention, cut-through routing at 2 Gbit/sec
Interoperability
SAN Switch 2/8-EL, SAN Switch 2/16-EL, SAN Switch 2/32, SAN Switch 2/64,
SAN Switch 8, SAN Switch 16, SAN Switch 8-EL, SAN Switch 16-EL,
Integrated/32, Integrated/64,
Switch bandwidth
32 Gbit/sec end to end
maximum frame size
2112-byte payload
port types
8 ports universal (one internal, seven external), FL_Port, F_Port, and E_Port;
self-discovery based on switch type (U_Port)
media types
Small form-factor pluggable (SFP) four included standard; short wavelength
(SWL) up to .31 mi (500m), long wavelength (LWL) up to 21 mi ( 35 km);
distance depends on fiber-optic cable and port speed
Classes of service
Class 2, Class 3, Class F (inter-switch frames)
management access
10/100 Ethernet port (RJ-45); Serial port (RS-232);
management
Advanced Web Tools included; Fabric Manager (optional) Management access
In-band via Management Server.
security
Fabric security for configuration management, SAN access, and
authentication/authorization
Supported software
Telnet, SNMP, WEBTOOLS, Zoning, Fabric Watch, Extended Fabrics, Remote
Switch, Trunking, Advanced Performance Monitoring
Fabric services
Simple Name Server, Registered State Change Notification (RSN), Alias Server
(multicast); and Zoning, WEB TOOLS. Optional QuickLoop, Fabric Watch,
Extended Fabrics, and Remote Switch, Trunking, Advanced Performance
Monitoring
diagnostics
Diagnostics POST and embedded online/offline diagnostics
dimensions (h x w x d)
Shipping
SAN Switch 2/8: 7.75 x 12.5 x 17 in (19.68 x 31.75 x 43.18 cm) 6 lb (2.72.kg))
humidity range
5% to 85% non-condensing at 40°C (104°F)
Environment
Temperature
Vibration
DA-11033
Operating
32° F to 104° F/0° C to 40° C
Non-operating
-31° F to 147° F/-25° C to 70° C
Operating
0.5 G p-p, 5-500 Hz
Non-operating
2.0 G p-p, 5-500 Hz
Connector Type
LC
Protocol
SCSI, IP
Data Transfer Method
64-bit/66 MHz PCI
Maximum Transfer Rate
200 MB
Packaging
Dimensions (L x W x D)
11 x 8.5 x 3 in/27.9 x 21.6 x 7.6 cm
Weight (Gross)
1 lb/0.45 kg
World Wide — Version 13 — July 23, 2003
22
QuickSpecs
HP StorageWorks Modular SAN Array 1000
Specific for Intel-based Servers Only
Technical Specifications
Multi-Mode Fibre Channel Cables Cable Type
Kits
Available Cable Lengths
Packaging
LC-LC (2 Gb to 2 Gb connections) and LC-SC (2 Gb to 1 Gb connections) 50
Micron multi-mode Fibre
6.5 ft, 16.4 ft, and 49.2 ft/2 m, 5 m, and 15 m
Dimensions (L x W x D)
11.5 x 9 x 1.5 in/29.2 x 22.8 x 3.8 cm
Weight (Gross)
0.75 to 1 lb/0.34 to 0.45 kg
© Copyright 2003 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation. Unix is a registered
trademark of The Open Group.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein
should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
DA-11033
World Wide — Version 13 — July 23, 2003
23
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF