BTc Controls RP - Altra Literature Portal

BTc Controls RP
RP Low Input Switching Control
Specifications
Main Power Input:
12 VDC
Main Input
Current:
25 Amps (at 25% duty cycle)
Operating
Temperature:
-20° F to +150° F (-29° C to 66° C)
Auxiliary 12V
Power Output:
12VDC
Low Input
Switching Current:
67mA
This control provides the switching logic to use low
current signal inputs for extending and retracting the
actuator rod/screw. It mounts on the back end of Warner
Linear’s 12VDC B-Track motor/actuator product.
Typical Wiring
Auxiliary 12V Power Output
Green - Ret
Orange - Ext
Extend
Retract
Red +
Black -
Fuse
12VDC 30A
12 VDC Power
Supply
Input
2-pin Packard 56
Connectors
All dashed lines are customer supplied connections
Actuator Extend = Orange +12VDC
Actuator Retract = Green +12VDC
Control Operation
Apply 12 VDC to the main power input. Use the same 12
VDC supply to apply positive voltage to the orange wire to
extend the actuator rod. When done extending, remove
the positive 12 VDC from the orange wire and apply to the
green wire to retract the actuator.
P-1581-WL-A4
The auxiliary power output is used to power additional
12VDC items as needed. The power is the same as the
“Main Power Input” applied by the customer to the 2-pin
Packard 56 connector. The total power available is based
on the customer supplied Power Input provided. The fuse
should then be sized to 135% of the total power needed.
8/17.... Warner Linear 800-825-6544
69