Edition: March 2011
Who is Bihl+Wiedemann?
The Company
Bihl+Wiedemann GmbH is a highly specialised internationally active company of engineers. It was founded on the 1st of April
1992 in Mannheim by Jochen Bihl and Bernhard Wiedemann
right after graduating in electrical engineering at the Technical
University of Darmstadt.
The idea was the development and production of electronic components for automation, especially fieldbus communication.
Today there are 2 main fields of activity:
Client specific developments and productions for fieldbus
communication
Our special fields of activity are the common national and international fieldbus systems like:
•
AS-i,
•
Bitbus,
•
CAN and CAN-Derivats like DeviceNet, CANopen,
CANrho etc.,
•
CC-Link,
•
CS 31,
•
ControlNet,
•
Ethernet TCP/IP,
•
InterBus,
•
Modbus, Modbus Plus,
•
PROFIBUS (FMS, DP, PA)
Thus customers have got the advantage to let manufacture in
case of little and medium quantities.
We offer services for all the steps in between as well: If you'd like
to fabricate the product devised by us yourself, we will supply
everything from the circuit design to the preparation and integration of software or the construction of prototypes. We carry out
the tests for the CE-sign and take the device through the certification. Do you want to place an order for only part of the job? No
problem, we take over any stage regarding software and hardware.
By the way: Development departments always are to busy or
have got insufficient work. Bihl+Wiedemann offers an solution for
this problem. If you are in many projects we support you if you
cannot do it yourself.
AS-i products
The own AS-i products - especially AS-i Masters and AS-i Gateways - have become quickly the main pillar of Bihl+Wiedemann.
A range of more than 70 AS-i Masters and AS-i Gateways has
been invented based on an own AS-i master technology. That is
why Bihl+Wiedemann describes itself as "AS-i Master". The product range is wided by AS-i slaves to interface complex devices
e.g. analog modules, or AS-i slaves for frequency inverters.
We support our customers, and development, marketing or distribution departments with development projects with fieldbus systems.
We carry out developments even for rough environments or for
the hazardous area. We carry out plans from the initial idea through to the finished serial product, including a high EMC, all the
tests compulsory for the CE-sign and certification by the respective fieldbus user organization. In addition to that, we can manufacture ourselves the products in low to medium volume and
deliver them to our clients in accordance with their respective
packaging regulations.
As specialists in AS-i Bihl+Wiedemann offers a hotline service to
help developers and users of AS-i products.
If there are any questions concerning AS-i contact us, we
provide a solution for your problem.
Our sales partner within Germany and abroad near your location
are qualified people to turn to.
Projektkoordination
Schaltungsentwurf
Hardwareund Softwareentwicklung
Prototypen
Produktion
Versand
Support
0-Serie
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 1
Inhaltsverzeichnis
1
AS-i Masters/Gateways/Links/Scanner
1.1
AS-i Masters in general
8
In General................................................................................................................................................................ 8
"AS-i Control" Mini-PLC for AS-Interface .............................................................................................................. 10
AS-i Gateways/Links ............................................................................................................................................. 11
1.2
AS-i Masters/Gateways/Links/Scanner
13
AS-i 3.0 PROFIBUS Gateway in Stainless Steel .................................................................................................. 16
AS-i 3.0 PROFIBUS Gateways in Stainless Steel, Ethernet diagnostics interface ............................................... 21
AS-i 3.0 DeviceNet Gateway in Stainless Steel .................................................................................................... 24
AS-i 3.0 CANopen-Gateways in Stainless Steel ................................................................................................... 26
AS-i 3.0 Modbus Gateway in Stainless Steel ........................................................................................................ 28
AS-i 3.0 EtherCAT Gateways in Stainless Steel ................................................................................................... 30
AS-i 3.0 Ethernet Gateways in Stainless Steel (Modbus TCP) ............................................................................. 32
AS-i 3.0 EtherNet/IP Gateways in Stainless Steel ................................................................................................ 34
AS-i 3.0 Ethernet/IP + Modbus TCP Gateways in Stainless Steel........................................................................ 36
AS-i 3.0 PROFINET Gateway in Stainless Steel................................................................................................... 38
AS-i 3.0 RS 232 Master in Stainless Steel ............................................................................................................ 40
AS-i 3.0 Master/Scanner for Allen-Bradley ControlLogix ...................................................................................... 41
AS-i 3.0 Master/Scanner for Allen-Bradley CompactLogix/MicroLogix 1500 ........................................................ 42
AS-i PROFIBUS Gateway in IP65......................................................................................................................... 43
AS-i/CC-Link Gateway .......................................................................................................................................... 44
AS-i/Modbus Plus Gateway................................................................................................................................... 45
1.3
AS-i-Master OEM-Module/PC-Boards
47
Overview AS-i Masters OEM Modules/PC Boards................................................................................................ 47
AS-i Master for PC based Automation .................................................................................................................. 48
AS-i 3.0 PCI Board ................................................................................................................................................ 49
AS-i PC2................................................................................................................................................................ 50
AS-i/PC104 Master................................................................................................................................................ 51
AS-i Master M-Module........................................................................................................................................... 52
AS-i-Master OEM-Modul ....................................................................................................................................... 53
Evaluation Kit for the AS-i Master OEM Module ................................................................................................... 54
1.4
Software
55
AS-i Control Tools ................................................................................................................................................. 56
Programming and Simulation Software for AS-i (Mini-PLC).................................................................................. 57
Software/Drivers for AS-i Masters ......................................................................................................................... 59
2
AS-i Slaves
2.1
AS-i-Analogmodule
61
AS-i Analog Modules............................................................................................................................................. 63
2.1.1
AS-i Analog Modules in IP20
AS-i 3.0 Analog Module: 2 analog Inputs .............................................................................................................. 64
AS-i 3.0 Analog Module: 2 analog Inputs .............................................................................................................. 66
AS-i Analog Module: 2 analog Outputs ................................................................................................................. 67
AS-i Analog Module: 2 analog Outputs for ±10 V.................................................................................................. 68
AS-i Analog Module: 4 analog Inputs .................................................................................................................... 69
AS-i Analog Module: 4 analog Outputs ................................................................................................................. 70
AS-i Analog Module: 4 Pt100 Inputs ..................................................................................................................... 71
AS-i Analog Module: 4 thermocouple type J resp. K inputs .................................................................................. 72
2.1.2
AS-i Analog Modules (PG) in IP65
AS-i Analog Module: 2 analog Inputs .................................................................................................................... 73
AS-i Analog Module: 2 analog Outputs ................................................................................................................. 74
AS-i Module: 4 Pt100/Pt1000 Inputs ..................................................................................................................... 75
AS-i Analog Module: 2 Pt100 Inputs + 2 Relais Outputs....................................................................................... 76
AS-i Balance Controller ......................................................................................................................................... 77
2.1.3
AS-i Analog Modules (M12) in IP65
AS-i 3.0 Analog Module: 2 analog Inputs (M12).................................................................................................... 78
AS-i 3.0 Analog Module: 2 analog Inputs (M12).................................................................................................... 80
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 4
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Inhaltsverzeichnis
AS-i 3.0 Analog Module: Analog Input and Output Module (M12) ......................................................................... 81
AS-i Analog Module: 4 analog Inputs (M12) .......................................................................................................... 83
AS-i Analog Module: 4 analog Inputs (M12) .......................................................................................................... 85
AS-i Analog Module: 4 Pt100 Inputs (M12)............................................................................................................ 87
2.2
OEM Modules/AS-i Special Slaves
89
OEM Modules/AS-i Slaves for Special Solutions................................................................................................... 92
AS-i 3.0 Analog Module: 2 analog Inputs............................................................................................................... 93
AS-i 2I/2O AB Module............................................................................................................................................ 94
AS-i-4I/3O AB Module............................................................................................................................................ 96
AS-i 4I/4O Module.................................................................................................................................................. 97
AS-i 4I/4O OEM Module ........................................................................................................................................ 98
AS-i 4I/4O Module, galvanical separated............................................................................................................... 99
AS-i 4I/4O Module with LEDs .............................................................................................................................. 100
AS-i 6O-AB Module.............................................................................................................................................. 101
AS-i 8I Module ..................................................................................................................................................... 102
AS-i 8I/8O Module, AS-i 16I/16O Module ............................................................................................................ 103
AS-i OEM Slave with serial Interface ................................................................................................................... 105
AS-i OEM Power Supply Module ......................................................................................................................... 106
2.3
Specialities
107
AS-i Relay Module in Stainless Steel (4I/3O, 4I/4O)............................................................................................ 108
AS-i Analog Module, 2 inputs Pt100 + 4 digital inputs/outputs in IP67 (M12)...................................................... 109
AS-i 3.0 Universal Module in IP65 ....................................................................................................................... 112
AS-i 4I/4O Module in Stainless Steel ................................................................................................................... 114
AS-i 8I Module in Stainless Steel......................................................................................................................... 115
AS-i 8 Output Module in Stainless Steel .............................................................................................................. 116
AS-i Counter Modul: A/B inputs ........................................................................................................................... 117
AS-i Counter Module: 1-Channel Input ................................................................................................................ 119
AS-i Counter Module (1 - 15): 1 Channel Input.................................................................................................... 120
AS-i Analog Module: 2 Inputs for Leuze ODSL 30 Distance Sensors ................................................................. 121
AS-i Code Block................................................................................................................................................... 122
AS-i/AS-i Coupler in IP20..................................................................................................................................... 123
AS-i/AS-i Coupler in IP65..................................................................................................................................... 124
2.4
Drive Solutions with AS-i
125
AS-i Drive Solutions ............................................................................................................................................. 126
Cylindrical AS-i Actuator 1I/3O, additional 24 V................................................................................................... 127
AS-i Slave for Frequency Inverters ...................................................................................................................... 128
AS-i 3.0 4I/4O Module for MOVI-SWITCH........................................................................................................... 129
AS-i 3.0 Motor Module for 2 Roller Drives, speed setting of AS-i parameter....................................................... 130
AS-i 3.0 Motor Module for 2 Roller Drives, speed setting of AS-i analog values or rotary switch........................ 132
2.5
AS-i Building Automation
135
AS-i EnOcean Slaves .......................................................................................................................................... 136
AS-i Modules for controlling dampers actuators .................................................................................................. 137
AS-i Module for controlling 230 V blinds .............................................................................................................. 141
AS-i 4I OEM Module for building services engineering........................................................................................ 143
AS-i 2I/2O OEM Module for building services engineering.................................................................................. 144
AS-i Modules for building services engineering ................................................................................................... 145
AS-i MP Bus Master............................................................................................................................................. 146
3
AS-i Accessories/Diagnostics/Commissioning
3.1
Diagnostics/Commissioning
147
AS-i Analyser Innovation Step 2 .......................................................................................................................... 148
3.2
AS-i Repeate/Tuner/Bus Termination
151
Circuit Extension .................................................................................................................................................. 152
AS-i Address Programming Device ..................................................................................................................... 149
AS-i Tuner, AS-i Bus Termination........................................................................................................................ 154
AS-i Repeater with bus termination IP20 ............................................................................................................. 156
AS-i Repeater IP20 .............................................................................................................................................. 157
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 5
Inhaltsverzeichnis
AS-i Repeater IP65 ............................................................................................................................................. 158
AS-i High Power Repeater IP20.......................................................................................................................... 159
3.3
AS-i Power Supplies
161
AS-i Power Supplies............................................................................................................................................ 163
AS-i Power Supply 1,8 A ..................................................................................................................................... 164
AS-i Power Supply 4 A/8 A.................................................................................................................................. 166
AS-i Wide Range Power Supply 8 A ................................................................................................................... 167
24 V to 30 V AS-i Power Supply in Stainless Steel 2 A....................................................................................... 169
4 A/8 A Power Supply for AS-i Master in Stainless Steel.................................................................................... 170
4 A Power Supply with 3 Phases for AS-i Master in Stainless Steel................................................................... 172
8 A Power Supply with 3 Phases for AS-i Master in Stainless Steel................................................................... 173
AS-i Power Supply Decoupling Unit for 2 AS-i Networks .................................................................................... 174
AS-i Power Extender ........................................................................................................................................... 175
AS-i Module for Power Decoupler ...................................................................................................................... 176
3.4
AS-i Profile Cables/Passive Distributors/Substructure Modules/Accessoires
179
AS-i Profile Cable ................................................................................................................................................ 181
AS-i Passive Distributor....................................................................................................................................... 182
AS-i Substructure Module ................................................................................................................................... 183
AS-i Stripping Tools............................................................................................................................................. 184
Data Transmission Cords.................................................................................................................................... 185
3.5
Development/Manufacturing of AS-Interface Components
189
AS-i 3.0 Function and EMC-Tester Master ......................................................................................................... 190
AS-i 3.0 SAP4, SAP5, AASI and ASI4U Programming and Test Tool ................................................................ 191
AS-i Slave Evaluation Board on basis ASI-SW+................................................................................................. 192
4
Other Fieldbusses/Master Simulators
4.1
Master Simulators
195
PROFIBUS DP Master Simulator, PROFIBUS UART......................................................................................... 196
PROFIBUS DP Master Simulator........................................................................................................................ 196
Serial PROFIBUS DP Master.............................................................................................................................. 197
DeviceNet Master Simulator................................................................................................................................ 198
CANopen Master Simulator................................................................................................................................. 199
Interface Converter RS 232C/RS 485 ................................................................................................................. 200
USB - RS 232 Interface Converter ...................................................................................................................... 201
4.2
Other Fieldbuses/Couplers
203
PROFIBUS Option Board.................................................................................................................................... 204
CAN/PROFIBUS Coupler.................................................................................................................................... 205
CANrho/PROFIBUS Coupler............................................................................................................................... 205
CAN/InterBus Coupler......................................................................................................................................... 206
5
AS-i Safety
5.1
AS-i Safety
207
AS-i Safety .......................................................................................................................................................... 212
5.2
AS-i Gateways with integrated Safety Monitor
215
AS-i 3.0 PROFIBUS Gateway with integrated Safety Monitor, 16 Release Circuits ........................................... 217
AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor........................................................................... 227
AS-i 3.0 PROFINET Gateways with integrated Safety Monitor........................................................................... 233
AS-i 3.0 EtherNet/IP+Modbus TCP Gateways with integrated Safety Monitor ................................................... 239
AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor ............................................................................. 245
AS-i 3.0 PROFIBUS Gateways, PROFIsafe for 1 AS-i network.......................................................................... 249
AS-i 3.0 PROFIBUS Gateways, PROFIsafe for 2 AS-i networks ........................................................................ 253
5.3
AS-i Safety Monitors
261
AS-i Safety Monitor in Stainless Steel with Ethernet diagnostic interface........................................................... 262
AS-i Safety Monitor in Stainless Steel, 16 Release Circuits................................................................................ 264
AS-i Safety Monitor in Stainless Steel, 1 or 2 Release Circuits .......................................................................... 266
Safety Basic Monitors.......................................................................................................................................... 268
Safety Basic Monitor Starter Kit .......................................................................................................................... 270
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 6
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Inhaltsverzeichnis
AS-i Safety Monitor, 1 or 2 Release Circuits........................................................................................................ 271
5.4
AS-i Safety Modules
273
AS-i Speed Monitor.............................................................................................................................................. 275
Speed Monitor head unit and Speed Monitor for 2 axis....................................................................................... 276
Connecting cable for Speed Monitor.................................................................................................................... 277
Adapter for Speed Monitor................................................................................................................................... 278
AS-i Safety 4I/2O Module with 8 / 4 safety Inputs and 2 (4) electronical safety outputs in IP20 ......................... 279
AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM- and 2 / 1 Safety Inputs.................................. 281
AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM input ......................................................... 285
AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 3O....................................................... 289
AS-i Safety Input Module (M12) IP67 for floating contacts .................................................................................. 293
AS-i Safety Input Module (M12) IP67 for optolectronis protective devices .......................................................... 295
AS-i Input Module for floating contacts IP20........................................................................................................ 297
Emergency stop and reception ............................................................................................................................ 298
AS-i Safety OEM Slaves ...................................................................................................................................... 299
AS-i Substructure Module in IP67........................................................................................................................ 301
5.5
AS-i Safety Accessories
303
Programming software ASIMON.......................................................................................................................... 304
Interface cables.................................................................................................................................................... 304
Chip cards............................................................................................................................................................ 305
6
Price List
6.1
Standard Price List
306
Standard Price List............................................................................................................................................... 306
6.2
Price List by Article Numbers
317
Price List by Article Numbers............................................................................................................................... 317
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 7
AS-i Master
In General
There's always one that fits....
AS-i Masters are the heart of each AS-i application. They are the
link to the superior system and therefore the most complex node
of the AS-i. Bihl+Wiedemann - The AS-i Masters - offers a wide
range of AS-i Masters to give the user the best solution for each
application. If it is necessary to connect AS-i to a special PLC, PC
or some other CPU, Bihl+Wiedemann has got the right AS-i Master.
If you need up to now there is a range of more than 70 different
types of AS-i Masters available with a wide variety of interfaces
to the host system:
PCI Board with 2 AS-i Masters
AS-i Gateways/Links
AS-i Gateways act as a Master for the AS-i and as a slave for the
higher level fieldbus, e.g. PROFIBUS, InterBus, CAN, Ethernet.
From the point of view of the higher level fieldbus the AS-i Gateway acts as a fieldbus slave with modular I/O, which converts the
data between the AS-i and the superior fieldbus system. AS-i Gateways offer the best possible solution to connect decentral AS-i
networks to a specific PLC via a fieldbus. AS-i Gateways with
"AS-i Control" functionality can optional preprocess the AS-i data
within the gateway.
AS-i Control
Beside using the Bihl+Wiedemann AS-i Masters as Gateways
can be used as stand-alone-controllers for small AS-i applications. There is no need for an additional PLC.
AS-i Masters for PC based automation
The technology within PC systems (both hardware and software)
has developed greatly with the price reduction in the industry.
This is one reason why PC based systems have been used in
ever wider applications, including industrial automation. In addition automation solutions have increasing access to PC based systems for graphical representation and control. In particular the
connection between PC system and fieldbus offers the possibility
for very powerful and inexpensive solutions. The high-quality industrial I/O devices are put to use decentrally while the PC is
used as an efficient hard- and software basis for the purposes of
control and visualization. The use of AS-i with PC systems is facilitated by the range of interface possibilities such as PCs in
combination with soft PLCs, own application software. Especially
in that field Bihl+Wiedemann offers the all common hard- and
software interfaces for PC based automation with AS-i.
Identical operation of all Masters and Gateways
In spite of this big range of different AS-i Masters and AS-i Gateways, all devices are operated identically. This means: A person
who knows one Bihl+Wiedemann AS-i Master can operate them
all.
Starting-up, debugging and setting up of the AS-i parameters on
the AS-i can be accomplished by using only push-buttons, LEDs
and display. With the help of the push-buttons and the display,
slave addresses can be programmed, several faulty AS-i slaves
can be detected and actual configurations on the AS-i network
can be stored. Integrated status-LEDs inform the user of the current operating condition at any time.
All AS-i Masters and AS-i Gateways can be put into operation
with the use of the windows software "AS-i Control Tools". The
PC software communicates with the AS-i Master via the serial or
parallel interface of the PC. The communication uses the protocol
of the respective fieldbus (PROFIBUS, DeviceNet, Modbus,
B+W-Protocol etc.). E. g. putting an AS-i/PROFIBUS Gateway
into operation with a PC requires only a simple PROFIBUS Mastersimulator. That way, the Gateways can be operated even with
notebooks via the respective fieldbus interface, without there
being a need for additional expensive hardware.
Advanced AS-i diagnostics
Bihl+Wiedemann AS-i Masters offer AS-i diagnostics which go
far beyond the standard diagnostics of the AS-i specification.
With Bihl+Wiedemann AS-i Masters it is no problem to detect occasionally occurring configuration errors at the AS-i. Furthermore
there is the possibility to judge the quality of the data communi-
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 8
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Master
cation on the AS-i cable. And all that without any additional expert tools.
with the existing standard AS-i Masters. As long as you do not
use the functions of the new specification the V3.0 AS-i Masters
run as V2.04 Masters. The user does not notice any difference.
Regarding to the downwarded compatibility the following points
have to be mentionend:
• The AS-i Masters can be used with old slaves.
• Existing PC software can be used.
Display of error counter and configuration errors with the help of
the AS-i Control Tools
AS-i according to specification 3.0
Easy design, dramatically reduced installation costs, high integrity and good diagnostics, these are different reasons that effected
the success of AS-i as the simplest automation networking solution. But good things can still be improved. For this reason the
AS-International Association completed the new AS-i specification 3.0 as early as 1998 to integrate further requirements of the
market into the system.
When will the rest of B+W Masters be deliverable as V3.0 Masters?
In Bihl+Wiedemann AS-i Masters the change to specification 3.0
is achieved by means of using a new software only.
The advantages are obvious:
• The change of existing products to V3.0 is very simple.
• You can resort to established hardware.
This means that finally V3.0 AS-i masters and gateways can be
made available to your requirements very quickly.
Already today Bihl+Wiedemann can offer AS-i Masters according
to the specification 3.0. Some V3.0 AS-i Master are compatible
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 9
AS-i Control
"AS-i Control" Mini-PLC for AS-i
Bihl+Wiedemann AS-i Masters can be delivered
with or without Mini-PLC.
AS-i Control is a PLC-functionality integrated into the B+W AS-i
Masters1 . It forms a Mini-PLC with up to 256 inputs and outputs
per AS-i circuit together with commercial AS-i I/O modules.
In combination with B+W AS-i Masters according to the new
specification 3.0 AS-i Control supports also the extension to 62
AS-i slaves per AS-i network, the evaluation of AS-i peripheral
faults as well as the automatic data exchange with AS-i analog
modules according to the standardized profile 7.3.
In that way up to 248 digital inputs and outputs and 124 analog
values can be processed via AS-i.
Integrated in an AS-i Master with serial interface AS-i Control is
the ideal mini-PLC for stand alone solutions for smaller machines
or plants.
Using AS-i Control in Gateways, i. e. the AS-i/PROFIBUS DP
Gateway, you are capable to preprocess the actuator-sensordata within the Gateway. This way the hierarchically higher PLC
is relieved. Thus AS-i Control helps decentralizing the control
task.
Typical applications are the fast execution of time critical operations directly within the Gateway.
Complete parts of plants or machines can be controlled independently by the Gateway.
Implemented in PC boards AS-i Control relieves the PC from the
time critical control tasks. With the PC boards AS-i PCI Board
with 2 AS-i Masters, AS-i PC2 and AS-i PC104 with AS-i Control
the control program is running on the AS-i board so that the PC
processor is not stressed by the hard real time requirements of a
control task. The full efficiency of the PC can be used for visualizing data, archiving data, etc.
The PLC program for AS-i Control can be edited with a commercial PC and is downloaded to the AS-i Master afterwards. The following programming tool is available: the easy-to-use Windows
software AS-i Control Tools for commissioning and programming
AS-i Control in IL.
Mini-PLC description
programm memory (EEPROM)
16 KB (AS-i PCi board 4 KB)
data memory (bit/byte flags)
8 KB
remanent data memory
128 Bytes
cycle time (1 KBit /1000 word instructions)
1,8 ms/2,0 ms up to 16 ms/18 ms depending on device
Processing
control commands
very close to STEP5™
additional operations
call of AS-i Master functions
flags/registers
8K
number of counters/timers
1024 each
counter resolution
16 bit
programmable time values
1 - 40950 ms
inputs/outputs
up to 248 I, 248 O, 124 analog values via AS-i slaves
Programming
programming languages
AWL
programming device
PC
programming platforms
Windows 95/98, Windows NT, Windows 2000
programming tools
AS-i Control Tools
bus connections
PROFIBUS, Modbus, ISA, PC104, PCI
Accessories:
• Software AS-i Control Tools for AS-i Master in Stainless Steel (art. no. BW1602, see page 56)
• Software AS-i Sim (art. no. BW1902, see page 57)
1.
AS-i Master is used here as a generic term for AS-i Gateways, AS-i PC boards and other AS-i Masters.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 10
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Gateways/Links
AS-i Gateways act as a Master for the AS-i and as a slave for the
higher level fieldbus. From the point of view of the higher level
fieldbus the AS-i gateway acts as a fieldbus slave with modular I/
O. The modules of this fieldbus slave can be mounted decentrally
and are connected via the intelligent AS-i cable. If you substitute
the I/O modules by one or more AS-i gateways you can use the
AS-i slaves right at the place where the actuators and sensors
are located. In that way there is no parallel wiring between the
respective fieldbus I/O module and the sensors and actuators.
Installation and cable costs can be reduced again in this way
because the AS-i concept is to optimize the networking of binary
sensors and actuators. With AS-i it is also very easy to prepare a
whole machine in your factory, separate it into several parts and
rebuild it very quickly at your customer's site. This installation can
even be done by the end user because of the quick and simple
installation.
respective PLC. No matter which PLC the machinery builder has
to use the structure of the plant from the AS-i gateway to the sensors and actuators remains constant. In that way the planning,
installation, commissioning and documentation can be the same
with every machinery.
Only the communication between the PLC and the AS-i gateway
changes. For these reasons Bihl+Wiedemann has developed
AS-i Gateways to the following fieldbus systems:
• PROFIBUS DP
• InterBus
• DeviceNet
• CANopen
• CANrho
• Ethernet TCP/IP
• Modbus Plus
• Modbus (RS 232, RS 485, RS 422)
• CC-Link
• LON
• B+W protocol (RS 232, RS 485, RS 422)
With one of all these Gateways it is always possible to connect
AS-i to all common PLCs.
The use of AS-i Gateways in high protection category IP65 facilitate the creation of new plant concepts in which cabinets and
preswitch boxes can be saved. That is why AS-i is an useful alternative for applications with more than 20 I/O points.
Field housing in IP20
You can built up parts of plants decentrally and put them together
as logical units with the help of AS-i gateways. With the superior
fieldbus system big distances, e.g. from the cabinet to the application, can easily be bridged. An AS-i gateway which is located
in the application offers the possibility to interface AS-i to the
With all Gateways it is possible to access all AS-i data via the
respective fieldbus interface. With the use of the internal miniPLC "AS-i Control" the host can intervene in the execution of the
program via the respective fieldbus interface. The reaction times
can be lowered and the hierarchically higher PLC is relieved
using the PLC functionality.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 11
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 12
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Masters/Gateways/Links/Scanner
AS-i 3.0 PROFIBUS Gateway
in Stainless Steel
BWU1567
1 AS-i Master, PROFIBUS slave
BW1653
1 AS-i Master, PROFIBUS slave, Class 1 Div 2
BWU1773
1 AS-i Master, PROFIBUS slave,
without RS232 diagnostics interface,
without duplicate address’ recognition
BWU1568
2 AS-i Masters, PROFIBUS slave
AS-i 3.0 PROFIBUS Gateway
in Stainless Steel
AS-i 3.0 DeviceNet Gateway
in Stainless Steel
AS-i 3.0 CANopen Gateway
in Stainless Steel
AS-i 3.0 Modbus Gateway
in Stainless Steel
AS-i 3.0 EtherCAT-Gateway
in Stainless Steel
BW1654
2 AS-i Masters, PROFIBUS slave, Class 1 Div 2
BWU1774
2 AS-i Masters, PROFIBUS slave,
without RS232 diagnostics interface,
without duplicate address’ recognition
BWU1569
2 AS-i Masters, PROFIBUS slave,
1 gateway + 1 AS-i power supply for 2 AS-i networks
BW1655
2 AS-i Masters, PROFIBUS slave, Class 1 Div 2
1 gateway + 1 AS-i power supply for 2 AS-i networks,
P.
16
BWU1746
Basic Master, 1 AS-i master, PROFIBUS slave
BWU1891
1 AS-i Master, PROFIBUS slave,
with decoupling coils
20
BWU2544
1 AS-i Master, PROFIBUS slave, Ethernet diagnostics
interface
21
BWU2545
2 AS-i Master, PROFIBUS slave, Ethernet diagnostics
interface
BWU2546
1 AS-i Master, PROFIBUS slave, Ethernet diagnostics
interface, 1 gateway + 1 AS-i power supply for 2 AS-i
networks
BWU1818
1 AS-i Master
BW1824
1 AS-i Master, Class 1 Div 2
BWU1819
2 AS-i Masters
BW1825
2 AS-i Masters, Class 1 Div 2
BWU1820
2 AS-i Masters
1 gateway + 1 AS-i power supply for 2 AS-i networks
BW1826
2 AS-i Masters, Class 1 Div 2,
1 gateway + 1 AS-i power supply for 2 AS-i networks
BWU1821
1 AS-i Master
BWU2225
1 AS-i Master, temperature range: -25 °C … +55 °C
BWU1822
2 AS-i Masters
BWU1823
2 AS-i Masters
1 gateway + 1 AS-i power supply for 2 AS-i networks
BWU1641
1 AS-i Master, Modbus Slave
BW1656
1 AS-i Master, Modbus Slave, Class 1 Div 2
BWU1642
2 AS-i Master, Modbus Slave
BW1657
2 AS-i Master, Modbus Slave, Class 1 Div 2
BWU1643
2 AS-i Master, Modbus Slave
1 gateway + 1 AS-i power supply for 2 AS-i networks
BW1658
2 AS-i Master, Modbus Slave, Class 1 Div 2
1 gateway + 1 AS-i power supply for 2 AS-i networks
BW2162
1 AS-i Master
BW2163
2 AS-i Master
BW2164
2 AS-i Master
1 gateway + 1 AS-i power supply for 2 AS-i networks
24
26
28
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Characteristics
Other Fieldbuses/
Master Simulators
Art. No.
AS-i Safety
Fieldbus
30
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 13
Price Lists
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i-Masters/Gateways/Links/Scanner
AS-i Masters/Gateways/Links/Scanner
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Housing
Fieldbus
Art. No.
Characteristics
AS-i 3.0 Ethernet/IP + Modbus TCP
Gateway in Stainless Steel
BWU2379
1 Master
BWU2380
2 AS-i Masters
BWU2381
2 AS-i Masters
1 gateway + 1 AS-i power supply for 2 AS-i networks
BWU1912
1 Master
BWU2238
2 AS-i Masters
1 gateway + 1 AS-i power supply for 2 AS-i networks
BWU2239
2 AS-i Masters
AS-i 3.0 PROFINET Gateway
in Stainless Steel
AS-i 3.0 Ethernet Gateway
in Stainless Steel
1 AS-i Master, Modbus TCP Slave, Class 1 Div 2
BW1660
2 AS-i Masters, Modbus TCP Slave, Class 1 Div 2
BW1661
2 AS-i Masters, Modbus TCP Slave, Class 1 Div 2
1 gateway + 1 AS-i power supply for 2 AS-i networks
36
38
32
BW1834
1 AS-i Masters, Class 1 Div 2
BW1835
2 AS-i Masters, Class 1 Div 2
BW1836
2 AS-i Masters, Class 1 Div 2
1 gateway + 1 AS-i power supply for 2 AS-i networks
AS-i 3.0 RS 232 Master
in Stainless Steel
BWU1955
1 AS-i 3.0 Master with serial interface
40
AS-i 3.0 Master for Allen-Bradley
ControlLogix
BW1611
complete set: AS-i 3.0 Master/Scanner for Allen-Bradley
ControlLogix BWU1488 plus accessories BW1563
41
AS-i 3.0 EtherNet/IP Gateway
in Stainless Steel
AS-i 3.0 Master for Allen-Bradley
CompactLogix/MicroLogix
AS-i/PROFIBUS Gateway
34
BWU1488
2 AS-i 3.0 Masters
BW1716
2 AS-i 3.0 Masters, Class 1 Div 2
BW1610
complete set: AS-i 3.0 Master/Scanner for Allen-Bradley
42
CompactLogix and MicroLogix BWU1416 plus accessories
BW1563
BWU1416
1 AS-i 3.0 Master
BW1253
1 AS-i Master, PROFIBUS slave, IP65
BW1371
1 AS-i Master, PROFIBUS slave, IP65
with M12 connector
43
Price Lists
AS-i Safety
BW1659
P.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 14
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Masters/Gateways/Links/Scanner
Art. No.
Characteristics
P.
AS-i/CC-Link Gateway
BW1435
1 AS-i Master, AS-i 2.1
44
AS-i/Modbus Plus Gateway
BWU1583
1 AS-i 2.1 Master, Modbus Plus node
45
AS-i-Master/Gateways/
Links/Scanner
Fieldbus
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 15
AS-i 3.0 PROFIBUS Gateway
in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 from ID no. 12003 (see lateral Label)
1 AS-i master
PROFIBUS slave
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Noise Detector integrated
Art. no.
BWU1567
Art. no.
BW1653
Class 1 Div. 2
(Group A, B, C & D, T-Code 4)
Operating current
master power supply
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
PROFIBUS interface
Serial interface
Baud rates
DP functions
BWU1773
AS-i 3.0 from ID no. 12470, without
RS232 diagnostics interface, without
recognition of duplicate AS-i addresses
according to DIN 19 245 Part 3
RS 232
-
9,6 KBaud up to 12000 KBaud, automatic recognition
imaging of the AS-i slaves as I/O Data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
150 μs*(number of slaves + 2)
AS-i cycle time
Other Fieldbuses/
Master Simulators
Displays
LCD
displaying slave addresses and error messages
LED green (power)
power on
LED green (PROFIBUS)
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
Buttons
4
≥ 500 V
Voltage of insulation
EMC directions
EN 61 000-6-2, EN 61 000-6-4
AS-i Safety
Operating temperature
0°C … +55°C
Storage temperature
Housing
-25°C … +85°C
AS-i master housing in stainless steel
Dimensions (L, W, H in mm)
120 / 75 / 83
Protection category (DIN 40 050)
Tolerable loading reffering to
impacts and vibrations
IP20
according to EN 61 131-2
Weight
460 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602, see also page 56))
Price Lists
• Serial PROFIBUS master (art. no. BW1258, see also page 197)
• PROFIBUS DP master simulator (art. no. BW1257, see also page 196)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 16
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
in Stainless Steel
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 from ID no. 12003 (see lateral Label)
2 AS-i masters
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
BWU1568
Art. no.
PROFIBUS interface
Serial interface
Baud rates
DP functions
master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA),
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA
BWU1774
AS-i 3.0 from ID no. 12470,
without RS232 diagnostics
interface, without recognition
of duplicate AS-i addresses
approx. 200 mA out of AS-i circuit 1
approx. 70 mA out of AS-i circuit 2
according to DIN 19 245 part 1-3
RS 232
-
9,6 KBaud up to 12 000 KBaud, automatic recognition
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
150 μs*(number of slaves + 2)
AS-i cycle time
Displays
LCD
displaying slave addresses and error messages
LED green (power)
power on
LED green (PROFIBUS)
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
Buttons
4
≥ 500 V
Voltage of insulation
EMC directions
EN 61 000-6-2, EN 61 000-6-4
Operating temperature
0°C … +55°C
Storage temperature
Housing
Other Fieldbuses/
Master Simulators
Operating current
BW1654
Class 1 Div. 2
(Group A, B, C & D,
T-Code 4)
-25°C … +85°C
AS-i Safety
Art. no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU1568: redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case
of power failure in one of the two AS-i networks
AS-i master housing in stainless steel
Dimensions (L, W, H in mm)
120 / 75 / 83
Protection category
(DIN 40 050)
IP20
Weight
460 g
• Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602, see also page 56)
• Serial PROFIBUS master (art. no. BW1258, see also page 197)
• PROFIBUS DP master simulator (art. no. BW1257, see also page 196)
• Power supply 4A (art. no. BW1649)/8A (art. no. BW1593) for BW1569, see also page 170
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 17
Price Lists
Accessories:
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS Gateway
in Stainless Steel
AS-i 3.0 from ID no. 12003 (see lateral Label)
2 AS-i masters
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU1569 and BW1655 in version
1 gateway, 1 power supply for 2 AS-i circuits:
Only 1 gateway + 1 AS-i power supply for 2 AS-i networks
Art. no.
BWU1569
Art. no.
BW1655
Class 1 Div. 2 (Group A, B, C & D, T-Code 4)
Operating current
version "1 gateway, 1 power supply for 2
AS-i circuits", approx. 250 mA
(PELV voltage)
PROFIBUS interface
according to DIN 19 245 part 1-3
Serial interface
Baud rates
DP functions
RS 232
9,6 KBaud up to 12000 KBaud, automatic recognition
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
150 μs*(number of slaves+ 2)
AS-i cycle time
Displays
Other Fieldbuses/
Master Simulators
LCD
displaying slave addresses and error messages
LED green (power)
LED green (PROFIBUS)
power on
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
Buttons
4
≥ 500 V
Voltage of insulation
EMC directions
EN 61 000-6-2, EN 61 000-6-4
Operating temperature
0°C … +55°C
AS-i Safety
Storage temperature
Housing
-25°C … +85°C
AS-i master housing in stainless steel
Dimensions (L, W, H in mm)
120 / 75 / 83
Protection category (DIN 40 050)
IP20
Weight
460 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602, see also page 56)
• Serial PROFIBUS master (art. no. BW1258, see also page 197)
• PROFIBUS DP master simulator (art. no. BW1257, see also page 196)
Price Lists
• Power supply 4A (art. no. BW1649)/8A (art. no. BW1593) for BW1569, see also page 170
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 18
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Art. no.
BWU1746
Operating current
master power supply
approx. 200 mA out of AS-i circuit (max. 300 mA)
Operating voltage
AS-i voltage 30 V DC
PROFIBUS interface
according to DIN 19 245 part 3
Baud rates
9,6 KBaud up to 12 000 KBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O Data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LED
displaying slave addresses and error messages
LED green (power)
power on
LED green (PROFIBUS)
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
Buttons
2
Voltage of insulation
≥ 500 V
EMC directions
EN 61 000-6-2, EN 61 000-6-4
Storage temperature
0°C … +55°C
-25°C … +85°C
Housing
AS-i master housing in stainless steel
Dimensions (L, W, H in mm)
120 / 45 / 40
Protection category (DIN 40 050)
IP20
Tolerable loading reffering to impacts according to EN 61 131-2
and vibrations
Weight
300 g
Accessories:
AS-i Safety
Operating temperature
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
1 AS-i 3.0 Master
PROFIBUS slave
Other Fieldbuses/
Master Simulators
AS-i 3.0 PROFIBUS-DP-Gateway/Link in Stainless Steel
Basic Master
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS Gateway
in Stainless Steel
• Software "AS-i Control Tools" (art. no. BW1203, see also page 56)
Price Lists
• Serial PROFIBUS master (art. no. BW1258, see also page 197)
• PROFBUS DP master simulator (art. no. BW1257, see also page 196)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 19
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS Gateway Stainless Steel
PROFIBUS DP Gateway/Link
with decoupling coils
1 AS-i-Master
PROFIBUS-Slave
Duplicate address’ recognition
AS-i earth fault detector integrated
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i noise detector integrated
Graphical display
Art. no. BWU1891
Operating current
master power supply approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
PROFIBUS interface
according to DIN 19 245 Part 3
Serial interface
RS 232
Baud rates
9,6 KBaud up to 12000 KBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LCD
displaying slave addresses and error messages
LED green (power)
power on
LED green (PROFIBUS)
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 50 295, EN 61 000-6-2, EN 61 000-6-4
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
AS-i master housing in stainless steel
Dimensions (L, W, H)
120 mm, 75 mm, 83 mm
Protection category (DIN 40 050)
IP20
AS-i Safety
Tolerable loading reffering to impacts and vibrations according to EN 61 131-2
Weight
460 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i master in stainless steel (art. no. BW1602)
• Serial PROFIBUS master (art. no. BW1258)
Price Lists
• PROFIBUS DP master simulator (art. no. BW1257)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 20
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateways
in Stainless Steel
1 AS-i master
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector distinguishes AS-i cable and sensor cable
AS-i Noise Detector integrated
Optional programmable in C
AS-i-Master/Gateways/
Links/Scanner
Ethernet diagnostics interface
GSD file integrated
BWU2544
Operating current
master power supply
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
PROFIBUS interface
according to DIN 19 245 Part 1-3
Diagnostics interface
Ethernet
Baud rates
9,6 KBaud up to 12 000 KBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O Data of the PROFIBUS
complete diagnosis and configuration via the DP Master
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LCD
displaying slave addresses and error messages
LED green (power)
power on
LED green (PROFIBUS)
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 61 000-6-2
EN 61 000-6-4
Storage temperature
0°C … +55°C
-25°C … +85°C
Housing
AS-i master housing in Stainless Steel
Dimensions (L / W / H in mm)
120 / 75 / 93
Protection category (DIN 40 050)
IP20
Tolerable loading reffering to impacts and vibrations according to EN 61 131-2
Weight
460 g
Accessories:
• Software "AS-i Control Tools"(art. no. BW1203, see also page 56)
AS-i Safety
Operating temperature
Other Fieldbuses/
Master Simulators
Article no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Power24V capable
• Serial PROFIBUS master (art. no. BW1258, see also page 197)
• PROFIBUS DP master simulator (art. no. BW1257, see also page 196)
Price Lists
• Power supply 4A (art. no. BW1649)/8A (art. no. BW1593, see also page 170)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 21
AS-i 3.0 PROFIBUS Gateways
in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
Ethernet diagnostics interface
2 AS-i masters
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector distinguishes AS-i cable and sensor cable
Optional programmable in C
GSD file integrated
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Power24V capable
BWU2545: redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case
of power failure in one of the two AS-i networks
Article no.
BWU2545
Operating current
master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA),
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA
PROFIBUS interface
according to DIN 19 245 part 1-3
Diagnostics interface
Ethernet
Baud rates
9,6 KBaud up to 12 000 KBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the DP Master
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LCD
displaying slave addresses and error messages
LED green (power)
power on
LED green (PROFIBUS)
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
AS-i Safety
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 61 000-6-2
EN 61 000-6-4
Operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
AS-i master housing in Stainless Steel
Dimensions (L / W / H in mm)
120 / 75 / 93
Protection category (DIN 40 050)
IP20
Weight
460 g
Accessories:
• Software "AS-i Control Tools"(art. no. BW1203, see also page 56)
Price Lists
• Serial PROFIBUS master (art. no. BW1258, see also page 197)
• PROFIBUS DP master simulator (art. no. BW1257, see also page 196)
• Power supply 4A (art. no. BW1649)/8A (art. no. BW1593, see also page 170)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 22
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateways
in Stainless Steel
2 AS-i masters
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector distinguishes AS-i cable and sensor cable
AS-i Noise Detector integrated
Optional programmable in C
AS-i-Master/Gateways/
Links/Scanner
Ethernet diagnostics interface
GSD file integrated
Current measurement of the AS-i circuits
Self-resetting adjustable fuses
BWU2546 in version
1 gateway, 1 power supply for 2 AS-i circuits:
Only 1 gateway + 1 AS-i power supply for 2 AS-i networks
Article no.
BWU2546
Operating current
version "1 gateway, 1 power supply for 2 AS-i circuits",
approx. 250 mA (PELV voltage)
PROFIBUS interface
according to DIN 19 245 part 1-3
Diagnostics interface
Ethernet
Baud rates
9,6 KBaud up to 12 000 KBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the DP Master
AS-i cycle time
150 μs*(number of slaves+ 2)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Power24V capable
displaying slave addresses and error messages
LED green (power)
power on
LED green (PROFIBUS)
PROFIBUS master recognized
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
master is in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 61 000-6-2
EN 61 000-6-4
Operating temperature
Storage temperature
0°C … +55°C
-25°C … +85°C
Housing
AS-i master housing in Stainless Steel
Dimensions (L /W / H in mm)
120 / 75 / 93
Protection category (DIN 40 050)
IP20
Weight
460 g
AS-i Safety
LCD
Other Fieldbuses/
Master Simulators
Displays
Accessories:
• Software "AS-i Control Tools"(art. no. BW1203, see also page 56)
• Serial PROFIBUS master (art. no. BW1258, see also page 197)
• Power supply 4A (art. no. BW1649)/8A (art. no. BW1593, see also page 170)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 23
Price Lists
• PROFIBUS DP master simulator (art. no. BW1257, see also page 196)
AS-i 3.0 DeviceNet Gateway
in Stainless Steel
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
DeviceNet to AS-i bridge
1 AS-i 3.0 master
AS-i Earth Fault Detector integrated
Recognition of duplicate AS-i addresses
AS-i Noise Detector integrated
Art. no.
BWU1818
Art. no.
BW1824 Class 1 Div 2
(Group A, B, C & D, T-Code 4)
Operating current
Operating voltage
Terminals
power supply A, approx. 200 mA out of AS-i
AS-i voltage 30 V DC
DeviceNet interface (5-pin plug)
RS 232 diagnostic interface
master profile M4 (AS-i specification 3.0)
150 μs* (number of slaves + 2)
AS-i Master profile
AS-i cycle time
Displays
LCD
LED green (power)
LED green/red (ser active)
LED red (config error)
LED green (U AS-i)
LED green (AS-i active)
LED green (prg enable)
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category DIN 40 050)
Tolerable loading referring to impacts
and vibrations
Weight
displaying AS-i slave addresses and error messages
voltage ON
module/network-status (MNS)
configuration error
AS-i voltage OK
AS-i in normal operation
automatic address programming enabled
configuration mode active
4 (mode/set)
≥ 500 V
EN 50 295, EN 61 000-6-2, EN 61 000-6-4
0°C … +55°C
-25°C … +85°C
AS-i master housing in stainless steel
120 mm, 85 mm, 83 mm
terminals IP20
according to EN 61 131-2
520 g
Accessories:
• Software "AS-i Control Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602, s. page 56)
• DeviceNet Master Simulator with USB interface (art. no. BW1420, s. page 198)
• Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
• AS-i Power Supply 4 A (art. no. BW1649, s. page 166)
Price Lists
Pin assignment:
Signal
Color
1
V+
red
2
CAN_H
white
3
Shield
n/a
4
CAN_L
blue
5
V-
black
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 24
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 DeviceNet Gateway
in Stainless Steel
AS-i-Master/Gateways/
Links/Scanner
DeviceNet to AS-i Bridge
2 AS-i 3.0 Masters
AS-i Earth Fault Detector integrated
Recognition of duplicate AS-i addresses
AS-i Noise Detector integrated
Operating current
Terminals
AS-i master profile
AS-i cycle time
Displays
LCD
LED green (power)
LED green/red (ser active)
LED red (config error)
LED green (U AS-i)
LED green (AS-i active)
LED green (prg enable)
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category DIN 40 050)
Tolerable loading referring to
impacts and vibrations
Weight
Art. no. BWU1820
BW1825 Class 1 DIv 2
(Group A, B, C & D, TCode 4)
W1826 Class 1 Div 2
(Group A, B, C & D, TCode 4)
master power supply,
approx. 200 mA out of AS-i circuit 1
version "1 power supply,
max. 200 mA out of AS-i circuit 1 approx. 70 mA out of AS-i circuit 2
1 gateway for 2 AS-i circuits",
(approx. 70 mA ... 200 mA)
approx. 250 mA (PELV supply)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA
DeviceNet interface (5-pin plug) RS 232 diagnostic interface
master profile M4 (AS-i specification 3.0)
150 μs* (number of slaves + 2)
displaying AS-i slave addresses and error messages
voltage ON
module/network status (MNS)
configuration error
AS-i voltage OK
AS-i in normal operation
automatic address programming enabled
configuration mode active
4 (mode/set)
≥ 500 V
EN 50 295, EN 61 000-6-2, EN 61 000-6-4
0°C … +55°C
-25°C … +85°C
AS-i master housing in stainless steel
120 mm, 85 mm, 83 mm
terminals IP20
according to EN 61 131-2
520 g
Accessories:
• Software "AS-i Control Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602, s.
page 56)
• DeviceNet Master Simulator (art. no. BW1420, s. page 198)
• Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
• AS-i Power Supply 4 A (art. no. BW1649, s. page 166)
• Power Supply 4 A (art. no. BW1597)/8 A (art. no. BW1598) for art. no. BW1826 and BWU1820 (s. page 170)
AS-i Safety
Art. no.
BWU1819
590 g
Signal
Color
1
V+
red
2
CAN_H
white
3
Shield
n/a
4
CAN_L
blue
5
V-
black
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 25
Price Lists
Art. no.
Other Fieldbuses/
Master Simulators
BWU1820, BW1826 in version
"1 Power Supply, 1 Gateway for 2 AS-i Circuits":
only 1 Gateway + 1 AS-i Power Supply for 2 AS-i Networks!
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU1819: redundant power supply out of AS-i:
all fundamental functions of the device remain available even in
case of power failure in one of the two AS-i networks
AS-i 3.0 CANopen Gateway
in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
CANopen-Gateway to AS-i
1 AS-i 3.0 master
Recognition of Duplicate AS-i addresses
Advanced Diagnostic Function
Operating current
Operating voltage
Terminals
AS-i Master profile
Baud rate
AS-i cycle time
CANopen-Features
Displays
LCD
LED green (power)
LED green/red (MNS)
LED red (config error)
LED green (U AS-i)
LED green (AS-i active)
LED green (prg enable)
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category DIN 40 050)
Tolerable loading refering to impacts and
vibrations
Weight
BWU1821
BWU2225
power supply A, approx. 200 mA out of AS-i
AS-i voltage 30 V DC
CANopen (5-pin plug), RS 232 diagnostic interface
Master profile M4 (AS-i Specification 3.0)
10/1000 KBaud
150 μs* (Number of slaves + 2)
extended boot-up, minimum boot-up, life guarding
COB ID Distribution: DBT, SDO, Default
Node ID Distribution: SDO, Switch
No of PDOs: up to 35 Rx, 35 Tx
PDO Modes: async, cyclic, acyclic
Device Specification: CiA DS-301
displaying AS-i slave addresses and error messages
voltage ON
module/network status (MNS)
configuration error
AS-i voltage OK
AS-i in normal operation
automatic address programming enabled
configuration mode active
4 (mode/set)
≥ 500 V
EN 50 295, EN 61 000-6-2, EN 61 000-6-4
0 °C … +55 °C
-25 °C … +55 °C
-25 °C … +85 °C
housing in stainless steel
120 mm, 85 mm, 83 mm
terminals IP20
according to EN 61 131-2
520 g
Accessories:
Pin assignment:
• Software "AS-i-Control-Tools" with serial transmission cord for connection of the AS-i Master
(art. no. BW1602, s. page 56)
• CANopen master simulator (art. no. BW1453, s. page 199)
• Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
• AS-i power supply 4 A (art. no. BW1649, s. page 166)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
Diagnostics/Development
AS-i Slaves
Art. no.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 26
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 CANopen Gateway
in Stainless Steel
CANopen-Gateway to AS-i
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Masters
Recognition of Duplicate AS-i addresses
Advanced Diagnostic Function
BW1822: redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks
Displays
LCD
LED green (power)
LED green/red (ser active)
LED red (config error)
LED green (U AS-i)
LED green (AS-i active)
LED green (prg enable)
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category DIN 40 050)
Tolerable loading refering to impacts
and vibrations
Weight
displaying AS-i slave addresses and error messages
voltage ON
module/network status (MNS)
configuration error
AS-i voltage OK
AS-i in normal operation
automatic address programming enabled
configuration mode active
4 (mode/set)
≥ 500 V
EN 50 295, EN 61 000-6-2, EN 61 000-6-4
0°C … +55°C
-25°C … +85°C
housing in stainless steel
120 mm, 85 mm, 83 mm
terminals IP20
according to EN 61131-2
520 g
AS-i Accessories/
Diagnostics/Development
AS-i Master profile
Baud rate
AS-i cycle time
CANopen-Features
master power supply,
version "1 Power Supply, 1 Gateway for 2 AS-i
max. 200 mA out of AS-i circuit 1
circuits", approx. 250 mA (PELV Supply)
(approx. 70 mA ... 200 mA)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA
CANopen (5-pin plug)
RS 232 diagnostic interface
Master profile M4 (AS-i Specification 3.0)
10/1000 KBaud
150 μs* (Number of slaves + 2)
extended boot-up, minimum boot-up, life guarding
COB ID Distribution: DBT, SDO, Default
Node ID Distribution: SDO, Switch
No of PDOs: up to 70 Rx, 70 Tx
PDO Modes: async, cyclic, acyclic
Device Specification: CiA DS-301
Other Fieldbuses/
Master Simulators
Terminals
BWU1823
AS-i Safety
Operating current
BWU1822
590 g
Accessories:
• Software "AS-i-Control-Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602)
• CANopen master simulator (art. no. BW1453)
• Data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226)
• AS-i power supply 4 A (art. no. BW1649)
• Power supply 4 A (art. no. BW1597)/8 A (art. no. BW1598) for art. no. BWU1823
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 27
Price Lists
Art. no.
AS-i Slaves
BWU1823 version 1 power supply, 1 gateway for 2 AS-i circuits:
only 1 gateway + 1 AS-i power supply for 2 AS-i networks!
AS-i 3.0 Modbus Gateway
in Stainless Steel
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 from ID no. 11833 (see lateral Label)
1 AS-i master, modbus slave
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
Art. no.
BWU1641
Art. no.
BW1656 Class 1 Div. 2 (Group A, B, C & D, T-Code 4)
Operating current
master power supply
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
Baud rates
1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115000 baud, adjustable parity;
default settings are: 9600 Baud, no parity, address 1
AS-i Master profile
M1
Serial interface
RS 485 (Modbus/Modbus RTU)
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LCD
displaying slave addresses and error messages
LED green (power)
power on
LED green (ser active)
Modbus interface
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
the master is in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
according EN 50082, EN 50081
AS-i Safety
Ambient operating temperature
0 °C … +55 °C
Storage temperature
-25 °C … +85 °C
Housing
AS-i master housing in stainless steel
Dimensions (L, W, H)
120 mm, 75 mm, 83 mm
Protection category (DIN 40 050) IP20
Tolerable loading reffering to
impacts and vibrations
according EN 61 131-2
Weight
460 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i Master in Stainless Steel (art. no. BW1602)
Price Lists
• Interface converter RS 232C/RS 485 (art. no. BW1094, see also page 200)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 28
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Modbus Gateway
in Stainless Steel
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 from ID no. 11833 (see lateral Label)
2 AS-i masters, modbus slave
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
Operating current
Baud rates
AS-i Master profile
Serial Interface
AS-i cycle time
Displays
LCD
LED green (power)
LED green (ser active)
LED red (config error)
LED green (U AS-i)
LED green (AS-i active)
LED green (prg enable)
LED yellow (prj mode)
Buttons
Voltage of insulation
EMC directions
Ambient operating
temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category
(DIN 40 050)
Weight
BWU1643
BW1657 Class 1 Div. 2
(Group A, B, C & D,
T-Code 4)
BW1658 Class 1 Div. 2
(Group A, B, C & D,
T-Code 4)
master power supply,
approx. 200 mA out of AS-i circuit 1 version "1 gateway, 1 power supply
max. 200 mA out of AS-i circuit 1 approx. 70 mA out of AS-i circuit 2
for 2 AS-i circuits",
(approx. 70 mA ... 200 mA)
approx. 250 mA (PELV supply)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA
1200, 2400, 4800, 9600, 19200, 38400, 57600 or 115000 baud, adjustable parity;
default settings are: 9600 Baud, no parity, address 1
M1
RS 485 (Modbus/Modbus RTU)
150 μs*(number of slaves + 2)
displaying slave addresses and error messages
power on
Modbus interface
configuration error
AS-i voltage OK
AS-i normal operation active
automatic address programming enabled
the master is in configuration mode
4
≥ 500 V
according EN 50082, EN 50081
0 °C … +55 °C
-25 °C … +85 °C
AS-i master housing in stainless steel
120 mm, 75 mm, 83 mm
IP20
Other Fieldbuses/
Master Simulators
Art. no.
BWU1642
460 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i Master in Stainless Steel (art. no. BW1602)
• Interface converter RS 232C/RS 485 (art. no. BW1094, see also page 200)
• Power Supply 4 A (art. no. BW1649)/8A (art. no. BW1593) for BWU1643 and BW1658, see also page 170
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 29
Price Lists
Art. no.
AS-i Safety
BWU1643 and BW1658 in version "1 gateway, 1 power supply
for 2 AS-i circuits":
only 1 gateway + 1 AS-i power supply for 2 AS-i networks
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU1642: redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks
AS-i 3.0 EtherCAT Gateways
in Stainless Steel
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
EtherCAT to AS-i
1 AS-i 3.0 master
Recognition of Duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
Art. no.
BW2162
Operating current
master power supply
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
EtherCAT interface
according to IEEE 802.3 (RJ-45 connector)
Baud rates
10/100 MBaud
AS-i cycle time
150 μs*(number of slaves+ 2)
Displays
LCDs
displaying slave addresses and error messages
LED green (power)
Power on
LED green (ser active)
EtherCAT network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
the master is in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082, EN 50 081
Operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
AS-i master housing in stainlees steel
Dimensions (L, W, H)
120 mm, 85 mm, 83 mm
Protection category (DIN 40 050)
IP20
Tolerable loading refering to impacts and vibrations according to EN 61 131-2
500 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602, see also page 56)
• Cross-Link cable (art. no. BW1304, see also page 186)
Price Lists
AS-i Safety
Weight
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 30
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 EtherCAT Gateways
in Stainless Steel
AS-i-Master/Gateways/
Links/Scanner
EtherCAT to AS-i
2 AS-i 3.0 Masters
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
BW2164 in version 1 gateway, 1 power supply for 2 AS-i circuits:
only 1 gateway + 1 AS-i power supply for 2 AS-i networks
Art. no.
Operating current
EtherCAT interface
Baud rates
AS-i cycle time
BW2163
BW2164
master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA
version "1 power supply,
1 gateway for 2 AS-i circuits",
approx. 250 mA (PELV supply)
according to IEEE 802.3 (RJ-45 connector)
10/100 MBaud
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW2163: redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks
150 μs*(number of slaves+ 2)
Displays
displaying slave addresses and error messages
power on
LED green (ser active)
EtherCAT network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
Buttons
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
the master is in configuration mode
Other Fieldbuses/
Master Simulators
LED green (power)
4
≥ 500 V
EN 50 082, EN 50 081
0°C … +55°C
-25°C … +85°C
AS-i master housing in stainlees steel
120 mm, 85 mm, 83 mm
Protection category
(DIN 40 050)
IP20
Weight
500 g
AS-i Safety
LCDs
Accessories:
Price Lists
• Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602, see also page 56)
• Cross-Link cable (art. no. BW1304, see also page 186)
• Power supply 4A (art. no. BW1649, see also page 166)/8A (art. no. BW1593, see also page 170) for art. no. BWU1652
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 31
AS-i 3.0 Ethernet Gateway
in Stainless Steel
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 from Ident. no. 11866 (see lateral Label)
1 AS-i Master, Modbus TCP Slave
Recognition of Duplicate AS-i Addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
Art. no.
BW1659
Class 1 Div 2 (Group A, B, C & D, T-Code 4)
Operating current
Master power supply
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
Ethernet TCP/IP interface
according to IEEE 802.3, 10BaseT, (RJ-45 connector), Modbus TCP
Baud rates
10/100 MBaud
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LCDs
displaying slave addresses and error messages
LED green (power)
Power on
LED green (ser active)
Ethernet network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
the master is in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082, EN 50 081
Operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
AS-i master housing in stainlees steel
Dimensions (L, W, H)
120 mm, 100 mm, 83 mm
Tolerable loading refering to
impacts and vibrations
according to EN 61 131-2
Weight
550 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602, see also page 56)
• Cross-Link cable (art. no. BW1304, see also page 186)
Price Lists
AS-i Safety
Protection category (DIN 40 050) IP20
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 32
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Ethernet Gateway
in Stainless Steel
2 AS-i Masters, Modbus TCP Slave
Recognition of Duplicate AS-i Addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
Operating current
Ethernet TCP/IP interface
Baud rates
AS-i cycle time
BW1660 Class 1 Div 2
(Group A, B, C & D,
T-Code 4)
BW1661 Class 1 Div 2
(Group A, B, C & D, T-Code 4)
approx. 200 mA out of AS-i circuit 1
approx. 70 mA out of AS-i circuit 2
version "1 Power Supply, 1 Gateway for 2 AS-i Circuits",
approx. 250 mA (PELV Supply)
according to IEEE 802.3, 10BaseT, (RJ-45 connector), Modbus TCP
10/100 MBaud
150 μs*(number of slaves + 2)
Displays
LCDs
LED green (power)
displaying slave addresses and error messages
power on
LED green (ser active)
Ethernet network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
Buttons
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
the master is in configuration mode
4
≥ 500 V
EN 50 082, EN 50 081
0°C … +55°C
-25°C … +85°C
Other Fieldbuses/
Master Simulators
Art. no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 from Ident. no. 11866 (see lateral Label)
AS-i master housing in stainlees steel
120 mm, 100 mm, 83 mm
Protection category (DIN 40 050)
IP20
Weight
550 g
Price Lists
• Software "AS-i Control Tools" with serial cable for AS-i master in stainlees steel (art. no. BW1602, see also page 56)
• Cross-Link cable (art. no. BW1304, see also page 186)
• Power supply 4A (art. no. BW1649, see also page 166)
AS-i Safety
Accessories:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 33
AS-i 3.0 EtherNet/IP Gateway
in Stainless Steel
1 AS-i 3.0 master
AS-i Earth Fault Detector integrated
Recognition of duplicate AS-i addresses
AS-i Noise Detector integrated
Art. no.
BW1834 Class 1 Div 2
(Group A, B, C & D, T-Code 4)
Operating current
Operating voltage
Terminals
power supply A, approx. 300 mA out of AS-i circuit
AS-i voltage 30 V DC
10/100 MBaud Ethernet, RJ-45 socket
RS 232 diagnostic interface
10/100 MBaud
150 μs*(Number of slaves + 2)
Baud rates
AS-i cycle time
Displays
LCD
LED green (power)
LED green (ser active)
LED red (config error)
LED green (U AS-i)
LED green (AS-i active)
LED green (prg enable)
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category (DIN 40 050)
Tolerable loading refering to
impacts and vibrations
Weight
displaying AS-i slave addresses and error messages
voltage ON
Ethernet network active
configuration error
AS-i voltage OK
AS-i in normal operation
automatic address programming enabled
configuration mode active
4 (mode/set)
≥ 500 V
EN 50 295, EN 61 000-6-2, EN 61 000-6-4
0°C … +55°C
-25°C … +85°C
housing in stainless steel
120 mm, 100 mm, 83 mm
terminals IP20
according to EN 61 131-2
550 g
Accessories:
• Software "AS-i Control Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602, s. page 56)
• Cross-Link cable (art. no. BW1304)
• AS-i power supply 4 A (art. no. BW1649, s. page 166)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
EtherNet/IP to AS-i
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 34
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 EtherNet/IP Gateway
in Stainless Steel
AS-i Earth Fault Detector integrated
Recognition of Duplicate AS-i Addresses
AS-i Noise Detector integrated
Operating current
Terminals
Baud rates
AS-i cycle time
Displays
LCD
LED green (power)
LED green (ser active)
LED red (config error)
LED green (U AS-i)
LED green (AS-i active)
LED green (prg enable)
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category
(DIN 40 050)
Tolerable loading refering to
impacts and vibrations
Weight
BW1835 Class 1 DIv 2
(Group A, B, C & D, T-Code 4)
BW1836 Class 1 Div 2
(Group A, B, C & D, T-Code 4)
approx. 200 mA out of AS-i circuit 1
version "1 power supply, 1 gateway for 2 AS-i circuits",
approx. 70 mA out of AS-i circuit 2
approx. 250 mA (PELV supply)
10/100 MBaud ethernet, RJ-45 socket
RS 232 diagnostic interface
10/100 MBaud
150 μs*(Number of slaves + 2)
displaying AS-i slave addresses and error messages
voltage ON
Ethernet network active
configuration error
AS-i voltage OK
AS-i in normal operation
automatic address programming enabled
configuration mode active
4 (mode/set)
≥ 500 V
EN 50 295, EN 61 000-6-2, EN 61 000-6-4
0°C … +55°C
-25°C … +85°C
housing in stainless steel
120 mm, 100 mm, 83 mm
terminals IP20
according to EN 61 131-2
550 g
620 g
Price Lists
Accessories:
• Software "AS-i Control Tools" with serial transmission cord for connection of the AS-i Master (art. no. BW1602, s. page 56)
• Cross-Link cable (art. no. BW1304)
• AS-i power supply 4 A (art. no. BW1649, s. page 166)
• Power supply 4 A (art. no. BW1597)
AS-i Safety
Art. no.
Other Fieldbuses/
Master Simulators
2 AS-i 3.0 Masters
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
EtherNet/IP to AS-i
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 35
AS-i 3.0 Ethernet/IP + Modbus TCP
Gateway in Stainless Steel
i
AS-i Master/Gateways/
Links/Scanner
EtherNet/IP + Modbus TCP in one device
Integated switch
1 AS-i 3.0 Master
AS-i Earth Fault Detector integrated
Recognition of Duplicate AS-i Addresses
Graphical Display
Art. no. BWU2379
Operating current
Master power supply
approx. 300 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
Interfaces
RJ-45: 10/100 MBaud Ethernet + Modbus TCP acc. to IEEE 802.3, integrated switch
RS 232: diagnostic interface
Baud rates
10/100 MBaud
AS-i cycle time
150 μs * (number of slaves + 2)
Displays
LCD
indication of slave addresses and error messages
LED green (power)
power on
LED green (ser active)
Ethernet network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
configuration mode active
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
Ambient operating temperature
Storage temperature
0°C … +55°C
-25°C … +85°C
Housing
AS-i master housing in stainless steel
Dimensions (L / W / H in mm)
120 / 85 / 83
Protection category DIN 40 050
IP20
Tolerable loading referring to
impacts and vibrations
according to EN 61 131-2
Weight
500 g
Accessories:
• Software „AS-i-Control-Tools" with serial cable for AS-i Master in stainless steel (art. no. BW1602, s. page 56)
• Cross link cable (art. no. BW1304)
• AS-i Power Supply 4 A (art. no. BW1649 s. page 166)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Noise Detector integrated
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 36
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Ethernet/IP + Modbus TCP
Gateway in Stainless Steel
AS-i-Master/Gateways/
Links/Scanner
Ethernet/IP + Modbus TCP in one device
Integated switch
2 AS-i 3.0 Master
AS-i Earth Fault Detector integrated
Recognition of Duplicate AS-i Addresses
AS-i Noise Detector integrated
BWU2380 redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks
Graphical Display
Art. no. BWU2380
Art. no. BWU2381
Operating current
approx. 200 mA out of AS-i circuit 1
approx. 70 mA out of AS-i circuit 2
version „1 gateway, 1 power supply for 2 AS-i
circuits“, approx. 250 mA (PELV supply)
Interfaces
RJ-45: 10/100 MBaud Ethernet + Modbus TCP acc. to IEEE 802.3, integrated switch
RS 232: diagnostic interface
Baud rates
AS-i cycle time
10/100 MBaud
150 μs * (number of slaves + 2)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU2381 in version 1 power supply for 2 AS-i circuits:
only 1 gateway + 1 AS-i power supply for 2 AS-i networks!
Displays
indication of slave addresses and error messages
voltage ON
LED green (ser active)
Ethernet network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic addresses programming enabled
LED yellow (prj mode)
Buttons
Voltage of insulation
EMC standards
Ambient operating temperature
Storage temperature
Housing
Dimensions (L / W / H in mm)
Protection category DIN 40 050
Tolerable loading referring to
impacts and vibrations
Weight
configuration mode active
4
Other Fieldbuses/
Master Simulators
LED green (power)
≥ 500 V
EN 50 295
EN 61 000-6-2
EN 61000-6-4
0°C … +55°C
-25°C … +85°C
AS-i master housing in stainless steel
120 / 85 / 83
IP20
according EN 61 131-2
AS-i Safety
LCD
500 g
•
•
•
•
Software „AS-i-Control-Tools" with serial cable for AS-i Master in stainless steel (art. no. BW1602, s. page 56)
Cross link cable (art. no. BW1304)
AS-i Power supply 4 A (art. no. BW1649, s. page 166)
Power supply 4 A (art. no. BW1597)/8 A (art. no. BW1598) for BWU2381 (s. page 170)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 37
Price Lists
Accessories:
AS-i 3.0 PROFINET Gateway
in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
PROFINET IO, offers IRT-technology, 1 integrated Switch
For BWU1912 from ID no. 12824
(see lateral label)
1 AS-i 3.0 Master
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Noise Detector integrated
Article no.
BWU1912
Operating current
Master power supply
approx. 300 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
PROFINET interface
RJ-45
Conformance class
B
Baud rates
10/100 MBaud
Serial interface
RS 232
Baud rate
19,2 KBaud
AS-i cycle time
150 μs*(number of slaves+ 2)
Displays
LCDs
displaying slave addresses and error messages
LED green (power)
power on
LED green PROFINET
PROFINET IO network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
the master is in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
Operating temperature
0°C … +55°C
-25°C … +85°C
Housing
AS-i master housing in stainlees steel
Dimensions (L / W / H in mm)
120 / 85 / 83
Protection category (DIN 40 050)
IP20
Tolerable loading refering to impacts and vibrations
according to EN 61 131-2
Weight
500 g
Accessories:
• Software "AS-i Control Tools" with serial cable for AS-i Master in Stainlees Steel (art. no. BW1602, page 56)
• Cross-Link cable (art. no. BW1304, page 186)
• AS-i Power Supply (art. no. BW1649, page 166)
Price Lists
AS-i Safety
Storage temperature
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 38
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFINET Gateway
in Stainless Steel
AS-i-Master/Gateways/
Links/Scanner
PROFINET IO, offers IRT-technology, 1 integrated switch
2 AS-i 3.0 master
Recognition of duplicate AS-i addresses
AS-i Earth Fault Detector integrated
AS-i Noise Detector integrated
BW2238 in version 1 gateway, 1 power supply for 2 AS-i circuits:
only 1 gateway + 1 AS-i power supply for 2 AS-i networks
PROFINET interface
Conformance class
Baud rates
Serial interface
Baud rate
AS-i cycle time
BWU2238
BWU2239
Version "1 Power Supply, 1 Gateway for 2 AS-i
Circuits", approx. 250 mA (PELV Supply)
master power supply,
max. 200 mA out of AS-i circuit 1
(approx. 70 mA ... 200 mA)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 200 mA);
in sum max. 270 mA
RJ-45
B
10/100 MBaud
RS 232
19,2 KBaud
150 μs*(number of slaves+ 2)
Displays
LCDs
LED green (power)
displaying slave addresses and error messages
power on
LED green PROFINET
PROFINET IO network active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
Buttons
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L / W / H in mm)
Protection category (DIN 40 050)
Tolerable loading refering to impacts and vibrations
Weight
Other Fieldbuses/
Master Simulators
Operating current
the master is in configuration mode
4
≥ 500 V
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
0°C … +55°C
-25°C … +85°C
AS-i master housing in stainlees steel
120 / 85 / 83
AS-i Safety
Article no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU2239: redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks
IP20
according to EN 61 131-2
500 g
• Software "AS-i Control Tools" with serial cable for AS-i Master in Stainlees Steel (art. no. BW1602, page 56)
• Cross-Link cable (art. no. BW1304, page 186)
• AS-i Power Supply (art. no. BW1649, page 166)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 39
Price Lists
Accessories:
AS-i 3.0 Master with serial interface
1 AS-i-Master
RS 232 interface
B+W standard protocol
for communication with the host
AS-i-Specification 3.0
Graphical display
AS-i Safety
Art. no. BWU1955
AS-i 3.0 without RS 232 diagnostic interface,
without duplicate address´ recognition
Operating current
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
Baud rates
1200, 2400, 4800, 9600, 19200, 38400, 57600 baud, automatic recognition
Serial interface
RS 232
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 RS 232 Master in Stainless Steel
LCD
displaying slave addresses and error messages
LED green (power)
power on
LED green (ser active)
serial interface active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
configuration mode active
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
according EN 61 100-6-2, EN 61 000-6-4
Ambient operating temperature
0 °C … +55 °C
Storage temperature
-25 °C … +85 °C
Housing
AS-i master housing in stainless steel
Dimensions (L, W, H)
120 mm, 75 mm, 83 mm
Protection category (DIN 40 050)
IP20
Tolerable loading refering to impacts and vibrations
according EN 61 131-2
Weight
460 g
Accessories:
•
•
•
•
Software "AS-i Control Tools" (art. no. BW1203, Seite 56)
AS-i power supply 4 A (art. no. BW1649, Seite 166)
24 V to 30 V AS-i power supply 2 A (art. no. BW1760, Seite 169)
D-sub-data cable 9-pin, 1,8 m (art. no. BW1058)
Price Lists
Pin assignment:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 40
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Master/Scanner for
Allen-Bradley ControlLogix
Allen-Bradley ControlLogix
2 AS-i Master
AS-i 3.0 from ID no. 12704
(see lateral Label)
Art. no. BW1611 complete set: AS-i 3.0 Master BWU1488 plus accessories BW1563
Art. no. BWU1488 AS-i 3.0 Master for Allen-Bradley ControlLogix
Art. no. BW1716 AS-i Master for Allen-Bradley ControlLogix
Class I Div. 2 (Group A, B, C & D, T-Code 4)
Function
The Bihl+Wiedemann AS-i Master for ControlLogix of Allen-Bradley
has 2 AS-i masters according to the new specification. A fast and
easy commissioning can be accomplished with the use of two pushbuttons and the display.
AS-i I/O data and status information is mapped into the PLC processor’s I/O data.
AS-i Scope
Diagnostics, which go far beyond the standard diagnostics facilitate
the simple detection of the occassionally occuring configuration
Operating voltage
AS-i cycle time
approx. 70 mA out of AS-i
approx. 390 mA out of power supply 5,1 V DC
approx. 150 mA out of power supply 24 V DC
AS-i voltage 30 V DC
150 μs*(Number of slaves + 2)
Displays
LED display
LED green (PWR)
displaying slave addresses and error messages
power on
LED green (OK)
communication and control information
LED red (Fault)
configuration error
LED green (U AS-i)
LED green ( AS-i act)
LED green (prg enable)
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category (DIN 40 050)
Weight
AS-i voltage OK
Other Fieldbuses/
Master Simulators
Operating current
BWU1488 / BW1716
AS-i normal operation active
automatic address programming enabled
the master is in configuration mode
2 (mode/set)
≥ 500 V
EN 50 082, EN 50 081
0°C … +55°C
-25°C … +85°C
housing for DIN-rail mounting
146 mm, 35 mm, 132 mm
AS-i Safety
Art. no.
errors and further irritations towards the AS-i communication. So in
case of an error the down time of machines can be minimized or you
can initiate preventive maintenance.
Commissioning and monitoring
The AS-i Master can be commissioned respectively programmed with
the help of the software "AS-i Control Tools". Commissioning, debugging and setting up the system without the software can only be
accomplished with the use of two push-buttons, the display and the
LEDs directly on the system.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i Master for
housing IP20
420 g
Accessories:
Price Lists
• Software "AS-i Control Tools" with serial transmission cord for Allen-Bradley AS-i Master (Art. no. BW1563)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 41
AS-i 3.0 Master/Scanner for Allen-Bradley
CompactLogix/MicroLogix 1500
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i-Master for
Allen-Bradley
CompactLogix
MicroLogix 1500
AS-i 3.0 from ID no. 12821
(see lateral Label)
Article No. BW1610 Complete set: AS-i 3.0 Master BWU1416 plus accessories BW1563
Article No. BWU1416 AS-i 3.0 Master for Allen-Bradley CompactLogix/MicroLogix 1500
Function
The Bihl+Wiedemann AS-i Master connects a CompactLogix
processor or a MicroLogix 1500 to an AS-i network. Fast, easy
set up into PLC backplane by the help of the new AS-i Master.
AS-i I/O data and status information is mapped into the PLC processor’s I/O data.
AS-i-Scope
Diagnostics, which go far beyond the standard diagnostics facilitate the simple detection of the occassionally occuring configuration errors and further irritations towards the AS-i communication.
Commissioning and monitoring
The AS-i Master can be commissioned respectively parametrized
with the help of the software "AS-i Control Tools".
Commissioning, debugging and setting up the system without the
software can only be accomplished with the use of two push-buttons, the display and the LEDs directly on the system.
Art. no.
BWU1416
Operating current
approx. 100 mA out of AS-i
approx. 450 mA out of power supply 5 V DC
Operating voltage
AS-i voltage 30 V DC
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LED display
displaying slave addresses and error messages
LED green (power)
power on
LED green (diag)
communication and control information
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
the master is in configuration mode
Push-buttons
2 (mode/set)
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082, EN 50 081
Operating temperature
AS-i Safety
So in case of an error the down time of machines can be minimized or you can initiate preventive maintenance.
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
102 mm, 35 mm, 132 mm
Protection category (DIN 40 050)
housing IP20
Weight
420 g
Accessories:
Price Lists
• Software "AS-i Control Tools" with serial transmission cord for Allen-Bradley AS-i Master (art. no. BW1563)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 42
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i/PROFIBUS Gateway
AS-i Specification 2.1
Entirely powered by AS-i
AS-i Scope function
Article no.
BW1253
BW1371
Connections
AS-i: electromechanical interface
(penetration technique)
PROFIBUS DP: heavy gauge terminals and
cage clamp terminal blocks
AS-i: electromechanical interface
(penetration technique)
PROFIBUS DP: via M12 connector
Operating current
Master power supply A, approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
PROFIBUS Interface
according to DIN 19 245 part 3
Baud rates
9,6 KBaud up to 12 000 KBaud, automatic recognition
PROFIBUS DP Functions
imaging of the AS-i slaves as I/O data of the PROFIBUS.
complete diagnosis and configuration via PROFIBUS
150 μs*(Number of slaves + 1)
AS-i cycle time
Displays
LED display
AS-i slave addresses and error messages
LED green (power)
Power on
LED green (Bus active)
PROFIBUS Master recognized
LED red (config error)
Configuration error
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic Adress Programming enabled
LED yellow (prj mode)
Other Fieldbuses/
Master Simulators
LED green (U AS-i)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i/PROFIBUS DP Gateway/Link
in Protection Class IP65
the Master is in configuration mode
Push-buttons
2 (mode/set)
≥ 500 V
Voltage of insulation
EMC directions
EN 50 082, EN 50 081
Ambient operating temperature
Storage temperature
0°C … +55°C
-25°C … +85°C
Housing
Dimensions (L, W, H)
90 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
M12 Connector:
housing IP65
355 g
Pin Function
1
+5 V (only for termination resistor)
2
RXD/TXD-N (A)
3
DGND (only for termination resistor)
4
RXD/TXD-P (B)
5
Shield
Connection of PROFIBUS interface on
cage clamp terminal block (IP65):
DIP
buttons
off
1 2 3 4 5
Bus Out (female)
6 7 8 9 10
clamp terminal
Pin Function
1
RxD/TxD-N
2
RxD/TxD-P
3
RxD/TxD-N
4
RxD/TxD-P
5
0V
6
Shield
7
FG function ground
8
FG function ground
9
Shield
AS-i Safety
Weight
10 +5 V
• Software "AS-i Control Tools" (art. no. BW1203, see page 56)
• Serial PROFIBUS Master (art. no. BW1258, see page 197)
• PROFIBUS DP Master Simulator DP V0 and DP V1
(art. no. BW1257, see page 196)
• Transmission cords (art. no. BW1097, see page 185)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 43
Price Lists
Accessories:
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i/CC-Link Gateway
AS-i/CC-Link Gateway
in Protection Class IP65
Entirely powered by AS-i
Advanced AS-i diagnostics
AS-i Specification 2.1
Article no.
BW1435
Connections
AS-i: electromechanical interface (penetration technique)
CC-Link: heavy gauge terminals and screw terminal blocks
Operating current
master power supply A, approx. 200 mA out of the AS-i circuit
Operating voltage
AS-i voltage 30 V DC
CC-Link interface
according to CC-Link specification
Baud rates
156 KBps up to 10 MBps
Type
remote device
Occupied stations
3
CC-Link functions
imaging of the AS-i slaves as RW data on CC-Link.
complete diagnosis and configuration via CC-Link
150 μs*(Number of slaves + 1)
AS-i cycle time
Displays
LCD
AS-i slave addresses and error messages. CC-Link baud rate and station number
LED green (PW)
Power on
Other Fieldbuses/
Master Simulators
LED green (L RUN)
CC-Link Run LED
LED red (L ERR)
CC-Link Error LED
LED green (SD)
CC-Link Send Data LED
LED green (RD)
CC-Link Receive Data LED
LED red (CONF ERR)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i ACTIVE)
AS-i normal operation active
LED green (PRG ENABLE)
AS-i automatic address programming enabled
LED yellow (PRG MODE)
AS-i Master is in configuration mode
Push-buttons
2 (mode/set)
≥ 500 V
Voltage of insulation
EMC directions
EN 50082, EN 50081
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Price Lists
AS-i Safety
Housing
Dimensions (L, W, H)
90 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
housing IP65
Weight
355 g
1
Connection of CC-Link
interface on screw terminal block 2
and arrangement on
3
circuit board
4
FG
5
DB
1
2
3
4
6
FG
6
7
8
9 10
7
SLD
8
DG
9
DA
10
DB
SLD
DG
Termination resistor:
To be removed if module is
not at the end of the line
buttons
set
m ode
DA
5
screw term inal block
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 44
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i/Modbus Plus Gateway
to Modbus Plus
AS-i Master
Modbus Plus node
Advanced AS-i diagnostics
Function
The AS-i/Modbus Plus Gateway serves to connect the ActuatorSensor-Interface to a hierarchically higher Modbus Plus network.
The Gateway acts as a complete Master for the AS-i and as a
node for Modbus Plus. All AS-i functions can be called via the
Modbus Plus network. As with all Masters of Bihl+Wiedemann,
commissioning, debugging and setting up of the AS-i parameters
Specification 2.1
can be accomplished with the use of two push-buttons, the LCD
display and the LEDs directly on the system, but it can also be
handled via Modbus Plus. Advanced AS-i diagnostics allows to
detect occasional occurring configuration errors and to judge the
quality of the AS-i communication are implemented.
Art. no. BWU1583
Operating current
master power supply A
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
Serial interface
Baud rates
AS-i Master profile
AS-i cycle time
Modbus Plus
1 MBit/s
M1
150 μs*(Number of Slaves + 1)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i Gateway
Displays
LED green (Modbus Plus)
LED red (config error)
LED green (U AS-i)
displaying slave addresses and error messages
power on
network indicator (diagnosis LED)
configuration error
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
Push-buttons
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
2 (mode/set)
≥ 500 V
EN 50 082, EN 50 081
0°C … +55°C
-25°C … +85°C
housing for DIN-rail mounting
75 mm, 100 mm, 110 mm
housing IP40
terminals IP20
Price Lists
Protection category (DIN 40 050)
the master is in configuration mode
Other Fieldbuses/
Master Simulators
LED green (power)
AS-i Safety
LCD
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 45
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i/Modbus Plus Gateway
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 46
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Masters OEM Modules/PC Boards
AS-i 3.0 Master PCI Board
Art. No.
Characteristics
P.
BW1922
with advanced diagnostics
BW2087
without RS 232 interface,
without duplicate address recognition
BW1911
AS-i 3.0 Master Compact PCI Board
AS-i PC2
BW1228
AS-i 2.1
50
AS-i PC104
BW1229
AS-i 2.1
51
AS-i Master M-Module
BW1230
AS-i 2.1
52
BW1670
for use together with the Evaluation Kit BW1565
53
BW1588
for AS-i 3.0 customer applications
AS-i Master OEM Module
with option for AS-i chip programming
BW1554
sample for different options
BW1565
easy configuration of the AS-i Master OEM Module
54
Price Lists
AS-i Safety
Evaluation kit for AS-i Master
OEM Module
BW2176
49
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Master/Module
Other Fieldbuses/
Master Simulators
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Masters OEM Modules/PC Boards
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 47
AS-i Master OEM Modules/PC Boards
AS-i Master/Gateways/
Links/Scanner
AS-i Masters for PC based Automation
The whole Technology around the PC systems (hardware and
software) has been turning more powerful with falling prices. This
is one reason why PC based systems have been used in growing
figures, also in industrial automation. Many possibilities to use a
PC in combination with soft PLCs, to write own application software in C, C++, Pascal, Delphi, Visual Basic etc., or to use visualization packages are indications that AS-i has been used in
combination with PC based automation. Especially in that field
Bihl+Wiedemann offers the all common hard- and software interfaces for PC based automation. For each problem the right AS-i
master solution.
For the direct integration of AS-i Masters into PC systems
Bihl+Wiedemann offers AS-i Masters with
room with the master display. As fieldbus application layer Modbus is used. Other protocols can be implemented on request.
Bihl+Wiedemann provides all common drivers for AS-i Masters:
OPC server, NT driver, 16 bit and 32 bit dll drivers, etc. free of
charge in the internet. In this way there is no need for a timeconsuming licensing procedure with key disks etc. The newest drivers can be downloaded on 24 hours a day, 365 days a year. It
does not matter where problems occur with the use of the
homepage users can ensure that they have got the right drivers.
Embedded AS-i Masters: AS-i Master OEM Module
• PCI-Bus interface with 2 AS-i Masters,
• PC/104-Modul.
These cards have got the PLC functionality "AS-i Control" (Fast
Logic) on board. While the AS-i Master controls the AS-i network
the full resources of the computer can be used for visualization or
other applications.
Further AS-i Masters to interface a PC are the AS-i Masters with
serial interface and the Gateway between AS-i and Ethernet
TCP/IP. The AS-i/Ethernet TCP/IP Gateway is an easy to use
device to link the AS-i directly to the company network. While the
Gateway is located near the application, the PC remains in the
The AS-i Master OEM module is ideal for integration in specific
electronics. The AS-i Master OEM module fullfills the new AS-i
specification 2.1 and supports all new AS-i functions. Additionally
the new OEM module is supporting all AS-i master specialities of
Bihl+Wiedemann as the special AS-i safety diagnostics, AS-i
analyser functions etc.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
• ISA-Bus interface or as
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 48
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Master PCI Board /
AS-i 3.0 Master Compact PCI Board
AS-i Master Board (BW1922, BW2087)
for AT-PCs with PCI slots
AS-i 3.0 Master Board (BW1911)
for AT-PCs with Compact PCI slots
BW1922
BW2087
Advanced AS-i diagnostics (BW1922):
duplicate address‘ recognition
AS-i earth fault detector integrated
AS-i noise detector integrated
RS 232 diagnostic interface
Art. No. BW1922: AS-i 3.0 Double Master with advanced diagnostics
Art. No. BW2087: AS-i 3.0 Double Master without RS 232 interface, without duplicate address‘ recognition
Art. No. BW1911: AS-i 3.0 Compact PCI Double Master
Advanced AS-i diagnostic function for the localization of occasionally occurring configuration errors as well as for the qualitative diagnosis of the AS-i communication are also implemented.
Article no.
The DPRAM interface provides an easy integration of the AS-i
PCI Board in any operating system (special drivers). The address
of the AS-i PCI Board does not have to be adjusted. The AS-i PCI
Board works with "Plug and Play". Up to 4 AS-i PCI Masters can
be used simultaneously in one PC. The AS-i PCI Board serves
the requirements of industrial use.
BW1922
Type
Duplicate address‘ recognition
For normal operation there is no need for an PC interrupt, but the
AS-i PCI Board is capable to generate interrupts cyclically with
every AS-i cycle or leaded by configuration errors or changes in
input data.
BW2087
BW1911
PCI Board
Compact PCI Board
yes
–
AS-i earth fault detector integrated
yes
–
AS-i noise detector integrated
yes
–
RS 232 diagnostic interface
yes
Interface
Serial interface
Program memory (EEPROM)
–
32 bit PCI Bus interface, 3,3 V/5 V
galvanic isolation to AS-i
AS-i circuit 1, AS-i circuit 2
RS 232
–
16 KB
–
Operating voltage
3,3 V/5 V DC and AS-i voltage
Operating current
approx. 300 mA out of 5 V power supply
approx. 100 mA out of 3,3 V power supply
approx. 70 mA out of AS-i per AS-i circuit
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
AS-i cycle time per AS-i circuit
≥ 500 V
EN 61 000-6-2, EN 61 000-6-4
0°C … +55°C
-25°C … +70°C
150 μs*(number of slaves + 2)
AS-i specification
3.0
AS-i master profile
M4
Requirements
Other Fieldbuses/
Master Simulators
The AS-i Master PCI Board realizes the functionality of two complete AS-i Masters on a PCI Board. In addition to that an implemented AS-i control unit performs as a PLC to preprocess the
AS-i data on the board (BW1922). Another additional function is
the integrated watchdog function.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW1911
AS-i Safety
•
•
•
•
AS-i-Master/Gateways/
Links/Scanner
2 AS-i Master on 1 board
IBM compatible PC 80 486, PCI
Accessories:
• AS-i Control Tools (Windows) (art. no. BW1602, v. page 56)
• AS-i power supply 4 A (art. no. BW1649, s. page 166)
• OPC Server
• AS-i power supply decoupling unit for 2 AS-i circuits
(art. no. BWU1943, s. page 174)
• DLL drivers for Win 2000 and Win XP; Linux driver
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 49
Price Lists
Connections
AS-i Master/Gateways/
Links/Scanner
AS-i PC2
AS-i Master Board
for AT-PCs
AS-i Control function
Watchdog
Advanced AS-i diagnostics
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Specification 2.1
Article no. BW1228
AS-i PC2 realizes the functionality of a complete AS-i Master on
a short PC-board. In addition to that an implemented AS-i Control
unit performs as a PLC and an additional watchdog watches
breakdowns on your PC system. If used without the AS-i Control
the board will work as a pure AS-i Master. While the AS-i PC2
board controls the AS-i network, the full resources of the computer can be used for visualization or other applications. For normal
operation there is no need for an interrupt, but the AS-i PC2 card
is capable to generate interrupts leaded by events. Only 3 bytes
of the I/O area are used. The watchdog can set the Master into
the offline phase, if it is not triggered by a PC program. Advanced
Article no.
BW1228
Type
short AT-board
Interface
8 bit ISA Bus interface,
galvanic separation from AS-i
AS-i diagnostics to detect occasional occurring configuration
errors and to judge the quality of the AS-i communication are
implemented.
AS-i PC2 uses a DPRAM interface for data exchange. This fact
provides an easy embedding of AS-i PC2 in any PC operating
system (special drivers). I/O-data is readable all time. Up to 8
AS-i PC2-Boards can be used simultaneously in one PC and can
share one interrupt. The board serves the requirements of industrial use.
Operating voltage
5 V DC and AS-i voltage
Operating current
approx. 200 mA out of power supply
approx. 70 mA from AS-i
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082
EN 50 081
Ambient operating temperature
Storage temperature
Requirements:
IBM compatible PC 80286 or higher
Accessories:
AS-i Control Tools (Windows) (art. no. BW1203,
see also page 56)
Examples in ANSI C and PASCAL, both with
source code
Drivers for:
Microsoft C, Borland C
0°C … +55°C
-25°C … +70°C
AS-i cycle time per AS-i circuit
150 μs*(number of slaves + 1)
AS-i specification
2.1
DLL drivers for:
Win 3.11, Win 95/98, Win NT 4.0, Win 2000
OPC Server
Power supply
with a conventional
power supply unit
Power supply
with an AS-Interface
power supply unit
Price Lists
AS-i Safety
AS-i Connections:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 50
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i/PC104 Master
AS-i-Master/Gateways/
Links/Scanner
AS-i Master Module
in PC/104 format
with AS-i Control function
Watchdog
Advanced AS-i diagnostics
Use as
embedded AS-i-Master
Article no.
AS-i/PC104 module is capable to generate interrupts cyclically
with every AS-i cycle or leaded by configuration errors or changes in input data. Several AS-i/PC104 Master modules can share
one interrupt.
The AS-i/PC104 Master uses a DPRAM interface for data exchange which reserves only 3 bytes on the PC/104 Bus
(ISA-Bus) and provides an easy integration of AS-i/PC104 Masters in any PC operating system (special drivers). The base address of data exchange can be determined via software. Up to 8
AS-i/PC104 modules can be used simultaneously in one PC/104
system. Beside the use in PC/104 systems this AS-i Master module can be implemented as embedded AS-i Master into specific
controllers.
BW1229
Type
PC/104 module
Interface
8 bit PC/104 interface, 16 bit connector;
galvanic separation from AS-i
Operating voltage
5 V DC and AS-i voltage
Operating current
approx. 200 mA out of PC power supply
approx. 70 mA from AS-i
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082
EN 50 081
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +70°C
AS-i cyle time
150 μs*(number of slaves + 1)
2.1
Dimensions (L / W / H in mm)
96 / 90 / 16
Accessories:
AS-i Control tools (Windows)
(Art. no. BW1203, see also page 56)
Examples
ANSI C and PASCAL both with source code
Drivers for:
Microsoft C, Borland C
DLL drivers for:
Win 3.11, Win 95/98 ,Win NT 4.0, Win 2000
OPC Server
Price Lists
AS-i specification
Requirements:
IBM compatible PC
PC/104 architecture 80 286 or higher
AS-i Safety
The AS-i/PC104 Master module realizes the functionality of a
complete AS-i Master on a PC/104 module (identical functions as
AS-i PC2 with ISA-bus interface). In addition to that an implemented AS-i Control unit performs as a PLC and an additional
watchdog watches breakdowns of the PC/104 system. While the
AS-i/PC104 Master controls the AS-i network, the full resources
of the computer can be used for visualization or other applications. Without using the AS-i Control feature the board works as
a pure AS-i Master. The activated watchdog sets the Master to
the offline phase, if it is not triggered by a PC program. Advanced
AS-i diagnostics to detect occasional occurring configuration errors and judge the quality of the AS-i communication are implemented. Normally there is no need for a PC interrupt, but the
Other Fieldbuses/
Master Simulators
Article no. BW1229
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Specification 2.1
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 51
AS-i Master/Gateways/
Links/Scanner
AS-i Master M-Module
AS-i Master Module
with M-Module Interface
Watchdog
Advanced AS-i diagnostics
AS-i Specification 2.1
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1230
The AS-i Master M-Module realizes the functionality of a complete AS-i Master on a M-Module (similar functions as AS-i PC2
with ISA-bus interface).
The module is with the VITA standard "M-Module Mezzanine
Specification".
The AS-i Master M-Module is supporting the following features:
• Single M-Module
The AS-i Master M-Module uses a DPRAM interface for data
exchange. The DPRAM interface is consuming 128 words, but
only the low bytes are used. The DPRAM interface is easy to use,
especially with any operating systems and with different programming languages.
• +5 V operating voltage
• no +/-12 V operating voltage
• 8 Bit data bus
• 8 Bit address bus
• Interrupt-capable, Typ A (software-end-of-interrupt)
• AS-i connection through COMBICON connectors on the front
• AS-i signal additional through Pin 23 and 24 of the Peripheral
Connectors
Article no.
BW1230
AS-i specification
2.1
Type
M-Module
Interface
8 bit M-Bus interface;
galvanic separation from AS-i
Beside the use in VMEbus or other systems through carrier
boards (for example 3U or 6U carrier boards) this AS-i Master
module can be implemented as embedded AS-i Master into specific controllers.
Operating voltage
5 V DC and AS-i voltage
Operating current
approx. 200 mA out of PC power supply
approx. 70 mA from AS-i
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082
EN 50 081
Ambient operating temperature
Storage temperature
Requirements:
Carrier boards for example 3U or 6U for
VME-bus system, Compact PCI etc.
Connections:
0°C … +55°C
-25°C … +70°C
AS-i cycle time
150 μs*(Number of slaves + 1)
Dimensions (L / W / H in mm)
150 / 53 / 14
Price Lists
AS-i Safety
The activated watchdog sets the Master to the offline phase, if it
is not triggered by a host program. Advanced AS-i diagnostics to
detect occasional occurring configuration errors and judge the
quality of the AS-i communication are implemented. Normally
there is no need for an interrupt, but the AS-i Master M-Module is
capable to generate interrupts cyclically with every AS-i cycle or
leaded by configuration errors or changes in input data.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 52
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Master OEM Module
l
AS-i-Master/Gateways/
Links/Scanner
AS-i Master Board as OEM Module
AS-i-Master OEM Module for integration
in specific electronics
AS-i Specification 3.0
AS-i Master specialities as
AS-i Safety diagnostics, AS-i Analyser functions etc.
Assembly variants optional, please contact us!
AS-i specification 3.0 and supports all new AS-i functions. Additionally the new OEM Module is supporting all AS-i Master specialities of Bihl+Wiedemann as the special AS-i Safety diagnostics,
AS-i Analyser functions etc.
The AS-i Master OEM board BW1588 is the optimal version for
use together with the main board of a customer today. AS-i has
to be connected by soldering a cable on the board.
BW1670 has additionally two wiring pins for the AS-i connection
so that this board can be used together with the evaluation kit
without any change.
BW1554 is showing further possiblities like LEDs, a Combicon for
AS-i connection and so on.
Customer-specific special versions are possible on short notice!
Article no.
BW1554/BW1588/BW1670/BW2176
AS-i Specification
3.0
Type
OEM Module
Dimensions (L /W /H)
73 mm, 37 mm, 14 mm
Weight
25 g
Interface
8 bit bus interface; galvanic separation to
AS-i
Operating voltage
5 V DC and AS-i voltage
Operating current
approx. 100 mA out of power supply
approx. 70 mA from AS-i
Voltage of insulation
≥ 500 V
EMC directions
according EN 50 081-2, EN 61 000-6-2,
EN 50 295
Operating temperature
Accessories:
• Evaluation Kit for AS-i Master OEM Module
(Art. no. BW1565)
• AS-i Configurator (Windows) "AS-i Control Tools"
0°C … +55°C
Storage temperature
-25°C … +70°C
Tolerable loading referring to
humidity
according EN 61 131-2
Tolerable loading referring to
impacts
according EN 61 131-2
Tolerable loading referring to
vibrations
according EN 61 131-2
AS-i cycle time per AS-i circuit 150 μs*(number of slaves + 2)
For more details see data sheet.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any dataMannheim, 29.3.11
page 53
Other Fieldbuses/
Master Simulators
The AS-i Master realizes the functionality of a complete AS-i
Master 3.0 on an OEM Module.
The module is supporting the following features:
• +5 V operating voltage
• 8 bit data bus
• 10 bit address bus
• Interrupt-capable
• AS-i connection also at 2.54 mm connection
• Wiring pin 2 x 15 pins 2.54 mm for the DPRAM Interface and
serial interface (TTL)
• Optional: AS-i connection through COMBICON connectors on
the front (BW1554)
The AS-i Master OEM Module is ideal for integration in specific
electronics. The AS-i Master OEM Module fullfills the new
AS-i Safety
Article no. BW2176 with option for AS-i chip programming
Article no. BW1670 for use together with the evaluation kit BW1565
Article no. BW1588 for AS-i 3.0 for customer applications
Article no. BW1554 sample for different options
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW1554
Price Lists
BW1670
AS-i Master/Gateways/
Links/Scanner
Evaluation Kit for the AS-i Master OEM Module
Evaluation Kit for the
AS-i Master OEM Module
Easy configuration of the
AS-i Master OEM Module
Article no.
BW1565
Interfaces
- AS-i (Combicon plug)
- RS 232 for connection to the PC
nicate with the OEM Module via the AS-i Control Tools. Furthermore the AS-i line is pinned to a Combicon plug.
With the help of the evualuation kit for the AS-i Master OEM Module the development of an AS-i Master will be very easy.
LED green
device is powered
Operating current
9 … 15 V DC, pole-protected
Operating voltage
12 V DC out of external power supply and AS-i voltage
Specification:
• AS-i Control Tools BW1203
• Data cable BW1058
• 12 V power supply
Connections of the RS 232 interface and arrangement on circuit board
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1565
The Evaluation Kit for AS-i Master OEM Module serves for easy
commissioning of the AS-i OEM Module. On the carrier board
there is a 5 Voltage controller and a RS 232 converter, to commu-
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 54
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Software
Characteristics
BW1602
with serial cable for AS-i Master in Stainless Steel
BW1563
with serial cable for Allen-Bradley AS-i Master
BW1203
Software AS-i Control Tools
BW2071
with serial cable for AS-i Master/Monitor in Stainless
Steel
BW2501
for Safety Monitors and AS-i Masters
Mini-PLC for AS-i
BW1902
Programming and Simulation Software for AS-i
OPC server for AS-i Masters
BW1222
Windows drivers for AS-i Masters
BW1099
AS-i Control Tools
ASIMON and AS-i Control Tools
Windows NT4 drivers
(Kernel mode drivers)
Linux drivers for AS-i PCI Board
P.
56
57
59
16 Bit DLL
BW1224
32 Bit DLL
BW1815
.NET and 32 Bit DLL
BW1102
for AS-i PC2 board
BW1223
for AS-i PCI board
BW1816
LINUX kernel 2.0 and 2.2
BW1817
LINUX kernel 2.4
59
59
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art. No.
59
Price Lists
AS-i Safety
Drivers and exmaples can be downloaded free of charge in the download area under http://www.bihl-wiedemann.de.
Other Fieldbuses/
Master Simulators
Software
AS-i-Master/Gateways/
Links/Scanner
Overview Software
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 55
AS-i Control Tools
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Software
for Configuration and Programming and
for AS-i Diagnostics and AS-i Safety Diagnostics
of Bihl+Wiedemann
AS-i Masters and
AS-i Gateways
Article no. BW1602: Software AS-i Control Tools with serial cable for AS-i Master in Stainless Steel
Article no. BW1563: Software AS-i Control Tools with serial cable for Allen-Bradley AS-i Master
Article no. BW1203: Software AS-i Control Tools
Article no. BW2071: ASIMON and AS-i Control Tools with serial cable for AS-i Master/Monitor in Stainless Steel
Article no. BW2501: ASIMON and AS-i Control Tools for Safety Monitors and AS-i Masters
.
General information
• operating system: Win 98 SE, Win Me, Win 2000, Win XP and Win NT4,
Vista 32-bit
• comprehensible operator guidance
• simple installation
• language: English/German
• extensive help menu
AS-i configuration editor
opening, saving, editing and managing of AS-i configurations
tool for the commissioning of AS-i
• graphical display of the AS-i network
alternative plain text display of the AS-i network
-many devices icons out of an icon archive
-simple embedding of own icons and devices
• display of the actual configuration on the AS-i (slave-profiles in plain language)
• comparison of actual configuration with the projected one
Other Fieldbuses/
Master Simulators
• programming of slave addresses
• projecting of the actual configuration
• reading of inputs
• writing of outputs
• writing of parameters
• projecting of individual slaves (Offline/Online)
• slave can be given its own name
AS-i address assistent
• automatic address of the AS-i slaves (no handheld necessary)
Advanced AS-i diagnostics
• display of AS-i slaves which caused configuration errors
• judgement of the quality of the AS-i communication by means of error counters
for every AS-i slave
AS-i Safety
• extended AS-i diagnostic functions
• AS-i Safety diagnostic without additional software for the AS-i monitor
possible
AS-i Master identity
• reading and writing of AS-i Master and AS-i Control flags
Further functions
• offline/online mode
• opening and saving of AS-i configuration files
• opening and saving of AWL-files
Can be used with the following AS-i Masters
• AS-i/PROFIBUS Gateways, AS-i/Modbus Gateways, AS-i/DeviceNet
Gateways, AS-i/Ethernet TCP/IP Gateway
• AS-i Control - AS-i Master with RS 232, RS 485, RS 422
Price Lists
• AS-i PC2, AS-i PC104, AS-i PCI Board
• AS-i Master/Scanner for Allen-Bradley ControlLogix, CompactLogix/MicroLogix 1500
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 56
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Bihl+Wiedemann AS-i Masters and AS-i Gateways
in Stainless Steel can be delivered
with or without Mini-PLC
Art. no. BW1902
AS-i Control is a PLC-functionality integrated into the B+W AS-i
Masters1. It forms a Mini-PLC with up to 256 inputs and outputs
per AS-i circuit together with commercial AS-i I/O modules.
Integrated in an AS-i Master with serial interface AS-i Control is
the ideal mini-PLC for stand alone solutions for smaller machines
or plants.
In combination with B+W AS-i Masters according to the new
specification 3.0 AS-i Control supports also the extension to 62
AS-i slaves per AS-i network, the evaluation of AS-i peripheral
faults as well as the automatic data exchange with AS-i analog
modules according to the standardized profile.
Using AS-i Control in Gateways, i. e. the AS-i/PROFIBUS DP
Gateway, you are capable to preprocess the actuator-sensor-data within the Gateway. This way the hierarchically higher
PLC is relieved. Thus AS-i Control helps decentralizing the control task.
In that way up to 248 digital inputs and outputs and 248 analog
values can be processed via AS-i.
Typical applications are the fast execution of time critical operations directly within the Gateway
General
• Makes the simulation of AS-i control programs possible.
• Tests the syntax of the program.
Display of:
• AS-i flags
• digital inputs and outputs
• analog inputs and outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Programming and Simulation Software for AS-i (Mini-PLC)
AS-i-Master/Gateways/
Links/Scanner
AS-i Sim
Other Fieldbuses/
Master Simulators
• flags
Characteristics
• all inputs, outputs, timers, counters and flags, that are used in the
program are displayed
1.
AS-i Master is used here as a generic term for AS-i Gateways, AS-i PC boards and other AS-i Masters.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 57
Price Lists
AS-i Safety
• automatic recognition of the attached slaves (Online)
AS-i Sim
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Mini-PLC Description
programm memory (EEPROM)
16 kb (AS-i PCi Board 4 kb)
data memory (bit/byte flags)
8 kb
remanent data memory
128 byte
cycle time (1 kbit /1000 word instructions)
1,8 ms/2,0 ms up to 16 ms/18 ms depending on device
Processing
control commands
very close to STEP5™
additional operations
call of AS-i Master functions
flags/registers
8 kb
number of counters/timers
1024 each
counter resolution
16 bit
programmable time values
1 - 40950 ms
inputs/outputs
up to 248 I, 248 O, 248 analog values via AS-i slaves
Programming
programming languages
AWL
programming device
PC
programming platforms
Windows 95/98, Windows NT, Windows 2000
programming tools
AS-i Control Tools
bus connections
PROFIBUS, Ethernet, DeviceNet, CANopen, Modbus, PCI
Syntax editor
• syntax editor with integrated syntax monitoring
• monitoring for german and english syntax
• colored marking
Other Fieldbuses/
Master Simulators
• cut, copy, paste, search and print available over right mouse button
Simulation
• online and offline simulation
• single-cycle or cyclic prozessing
• speed tuning for the cyclic prozessing
Display of:
• variable state
AS-i Safety
• calculated connection-result and accumulator content
Scope of supply:
• Programming and Simulation Software for AS-i (Mini-PLC)
• Software AS-i Control Tools (Art. no. BW1203, see also page 56)
Price Lists
• Serial cable and adapter for AS-i Master in Stainless Steel
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 58
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Bihl+Wiedemann provides all common drivers free of charge in the internet. In this way there is no need for a time-consuming licencing procedure with key disks etc. The newest drivers can be downloaded on 24
hours a day, 365 days a year. It does not matter where problems occur
with the use of the homepage users can ensure that they have got the
right drivers. The drivers can also be ordered on disc.
AS-i-Master/Gateways/
Links/Scanner
Software/Drivers for AS-i Masters
Art. no. BW1222
The OPC server for the AS-i offers the possibility to exchange data
between the respective AS-i Master and a SCADA software package via
a standardized interface. In that way all Bihl+Wiedemann AS-i Masters
can get connected to the leading visualisations systems e. g. WinCC, RS
View, Fix, Bridge View, Lab View, in Touch, Client. The OPC server
already fulfils the AS-i specification 2.1. First test of the OPC server can
be made without any AS-i master hardware.
The "AS-i Control Tools" can be used as configurator to commission the
AS-i.
Windows drivers for AS-i Masters
Art. no. BW1099: 16-bit DLL
Bihl+Wiedemann provides AS-i DLLs for free. There are 16 bit DLLs for
Windows 3.1/3.11 and 32 bit DLLs for Windows 95/98 and Windows NT.
Art. no. BW1224: 32-bit DLL
The DLL interface is identically for all different AS-i Masters.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
OPC server for AS-i Masters
Windows NT4 drivers (Kernel mode drivers)
Art. no. BW1102: AS-i PC2 Board
Fast device drivers to use the AS-i PC boards in combination with Windows NT can also be downloaded free of charge.
Art. no. BW1223: AS-i PCI Board
Linux drivers for AS-i PCI Board
Other Fieldbuses/
Master Simulators
Art. no. BW1815: .NET and 32-bit DLL
Art. no. BW1816: LINUX kernel 2.0 and 2.2 Fast device drivers to use the AS-i PC boards in combination with LINUX
can also be downloaded free of charge.
Price Lists
Drivers and exmaples can be downloaded free of charge in the download area under http://www.bihl-wiedemann.de.
AS-i Safety
Art. no. BW1817: LINUX kernel 2.4
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 59
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 60
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Modules
AS-i Analog Output Module
AS-i Analog Input Module
AS-i Analog Output Module
AS-i Analog Input Module
AS-i Analog Input Module
AS-i Analog Output Module
Characteristic
P.
BWU1897
2 analog inputs, 4 … 20 mA and 0 … 10 V
64
BWU1345
2 analog inputs, 4 … 20 mA and 0 … 10 V
66
BWU1447
SIEMENS compatible scale
BWU1726
default power supply 24 V external
BWU1412
2 analog outputs, 0 … 20 mA and 0 … 10 V
BWU1727
default power supply 24 V external
67
BWU2224
2 analog outputs for ± 10 V
68
BWU1364
4 analog inputs, 4 … 20 mA
69
BWU1365
4 analog inputs, 0 … 10 V
BWU1366
4 analog outputs, 0 … 20 mA
BWU1367
4 analog outputs, 0 … 10 V
BWU1368
4 Pt100 inputs
71
BWU1933
4 thermocouple inputs type J
72
BWU2243
4 thermocouple inputs type K
BWU1232
2 analog inputs, 4 … 20 mA, protection category IP65
BWU1233
2 analog inputs, 0 … 10 V, protection category IP65
BWU1234
2 analog outputs, 0 … 20 mA, protection category IP65
BWU1235
2 analog outputs, 0 … 10 V, protection category IP65
70
73
74
BWU1254
4 Pt100 inputs, protection category IP65
BWU1509
4 Pt1000 inputs, protection category IP65
BWU1552
2 Pt100 inputs + 2 relais outputs, protection category IP65
AS-i Balance Controller
BW2240
AS-i connection for a 6 lines balance cell,
77
protection category IP65, calibration with AS-i Control Tools
AS-i Analog Input Module
BWU1893
2 inputs 4 ... 20 mA on AS-i with M12 connectors,
protection category IP65, AS-i 3.0 AB slave
BWU1894
2 inputs 4 ... 20 mA on AS-i with M12 connectors,
protection category IP65, AS-i 2.1 single slave
BWU1895
2 inputs Pt100 on AS-i with M12 connectors,
protection category IP65, AS-i 3.0 AB slave
BWU2086
see BWU1895,
second input via ID1 deactivated
BWU2050
2 inputs Pt100 on AS-i with M12 connectors,
protection category IP65, AS-i 2.1single slave
BWU1963
2 inputs 0 … 10 V on AS-i with M12 connectors,
protection category IP65, AS-i 3.0 AB slave
BWU1964
2 inputs 0 … 10 V on AS-i with M12 connectors,
protection category IP65, AS-i 2.1 single slave
AS-i Analog Module
75
76
78
80
Price Lists
AS-i Analog Input Module
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Analog Input Module
Art. No.
Other Fieldbuses/
Master Simulators
Module
AS-i Safety
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Analog Modules
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 61
AS-i Analog Modules
Module
Art. No.
Characteristic
AS-i Analog Module
BWU1853
1 analog input/1 analog output, 4 ... 0 mA or 0 ... 10 V in one 81
module, 24 V auxiliary on M12, protection category IP65
BWU1917
1 analog input/1 analog output, 4 ... 0 mA or 0 ... 10 V in one
module, supplied out of AS-i, protection category IP65
BWU1359
4 analog inputs on M12 socket, 4 … 20 mA,
protection category IP65
BWU2049
4 analog inputs on M12 socket, 4 … 20 mA,
protection category IP65, Siemens format
BWU1360
4 analog inputs on M12 socket, 0 … 10 V,
protection category IP65
BWU1742
4 analog inputs on M12 socket, 0 … 10 V, advanced
temperature range, protection category IP65
BWU1361
4 analog outputs on M12 socket, 0 … 20 mA,
protection category IP65
BWU1362
4 analog outputs on M12 socket, 0 … 10 V,
protection category IP65
BWU1722
4 analog outputs on M12 socket, 0 … 20 mA,
protection category IP65
BWU1736
4 analog outputs on M12 socket, 0 … 10 V,
advanced temperature range, protection category IP65
BWU1363
4 Pt100 inputs on M12 socket, protection category IP65,
4-wire mode
BWU2532
4 Pt100 inputs on M12 socket, protection category IP65,
3-wire mode
AS-i Analog Input Module
AS-i Analog Output Module
AS-i Analog Module
P.
83
85
87
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Housing
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 62
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Analog data such as pressure and room temperature is transmitted by the module in interference-free digital signal form. In factory applications the module is installed as with isolation amplifier
or real power transformer. The protection class IP65 modules are
simply clamped onto the AS-i cable via AS-i penetration technology and then directly supported by the AS-i master: Simply Plug
and Play! There is no need to program a function block to transmit the AS-i analog value via AS-i. The range consists of different
AS-i analog modules:
AS-i Analog Module (PG) in IP65
AS-i Analog Module IP20, 2 channels
AS-i Analog Module IP20, 4 channels
AS-i Analog Module (M12) in IP65, 2 channels
AS-i Analog Module (M12) in IP65, 4 channels
Price Lists
AS-i Analog Module (M12) in IP65
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
2/4 analog inputs 0 - 10 V, 2/4 analog inputs 4 - 20 mA, 4 analog
inputs Pt100, 2/4 analog outputs 0 - 10 V, 2/4 analog outputs
0 - 20 mA. The modules with IP65 protection can be directly installed in the field.
Other Fieldbuses/
Master Simulators
The user's advantages are abvious. He does not have to pay attention to the handling of the data transmission. This means in
the majority of applications that the transmission time of analog
values via AS-i will be reduced because the transmission time
depends on the AS-i cycle time and not as it was before on the
cycle time of the PLC program.
Bihl+Wiedemann has developed AS-i analog modules for safe
and direct connection of sensors and actuators according to the
new standardized Profile 7.3.
AS-i Safety
With the new AS-i specification it is possible to transmit analog
values via AS-Interface as simple as binary signals. For these
reasons the new AS-i slave profiles 7.3 and 7.4 for the transmission of analog values have been defined. According to the
profil 7.3 the AS-i master puts the analog slaves into operation in
the same way as the digital slaves and startes the data exchange
automatically. The host system (PC, PLC, Fieldbus) can read the
16 bit-value directly out of the AS-i master. The analog value
transmission between AS-i master and AS-i slave is done invisibely for the user.
AS-i-Master/Gateways/
Links/Scanner
AS-i Analog Modules
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 63
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 Analog Module: 2 analog Inputs
2 analog inputs, either 4 … 20 mA or 0 … 10 V
AS-i 3.0 Specification
AB Slave (up to 62 slaves)
Profil 7.A.9 „Plug and Play“
as simple as digital AS-i I/O
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP20
Article no. BWU1897
Article no.
2 inputs
Other Fieldbuses/
Master Simulators
4 … 20 mA
0 … 10 V
AS-i 3.0 AB Slave
Voltage supply, sensors
via AS-i/extern
Internal resistance
50 Ω
Max. input current
40 mA
–
Max. input voltage
–
25 V
Range of value
100 kΩ
14 bit/1 μA
14 bit/1 mV
4000 … 20000 dec.
0 … 10000 dec.
AS-i Profile
7.A.9
ID Code
Ahex
ID1 Code
see table code-definition
ID2 Code
9hex
IO Code
7hex
(Bit-setting of AS-i parameters)
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
Bit P1:
1: normal operation
0: both channels in current mode and
without broken wire recognition
Bit P2:
1: peripheral fault is indicated
0: peripheral fault is not indicated
Displays
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (AUX)
voltage supply 24 V for the analog part
LED green (INT)
voltage supply for the analog part out of AS-i
1
I1 Sig.+
state of channel 1
2
I1 Sig.-
LED green (Input Status 1)
AS-i Safety
Programming:
BWU1897
AS-i Specification
Resolution
LED green (Input Status 2)
state of channel 2
Connections:
3
24 V ext.
LED green (Input Mode 1)
channel 1: LED on: current measurement,
4
0 V ext.
LED off: voltage measurement
5
I2 Sig.+
LED green (Input Mode 2)
channel 2: LED on: current measurement,
6
I2 Sig.-
LED off: voltage measurement
7
24 V ext.
Operating current
< 80 mA
8
0 V ext.
Operating voltage
AS-i (30 V DC)
9
U1 Sig.+
Voltage of insulation
EMC directions
Ambient operating temperature
Price Lists
The position of the slide switches is indicated over LEDs.
The conversion of the measured value and the data transmission
via AS-i occurs asynchronically according to AS-i Profile 7.A.9.
The resolution of the analog data is 14 bit. The analog modules
contains 50 Hz and 60 Hz filters. These filters can be optionally
activated with the help of the AS-i parameters.
The analog module has 2 analog inputs.
The connection of sensors is made by Combicon clamps. Current
or voltage modules can be attached over different clamps. The
current supply of the sensors can take place depending upon
position of a slide switch from AS-i or from external voltage (after
PELV).
With the help of a 2. slide switch the 2. channel in favor of faster
data communication can be switched off.
Storage temperature
Housing
Dimensions (L, W, H)
Protection category (DIN 40 050)
≥ 500 V
10 U1 Sig.-
EN 61 000-6-2, EN 61 000-6-4
11 U2 Sig.+
0°C … +70°C
I1
I1
Sig+ Sig–
I2
I2
Sig+ Sig–
24 V
EXT
24 V
EXT
0V
EXT
0V
EXT
Input Status Input Mode
–
1 2 1 2
ER.
OK
U
I
FAULT
INT
PWR
AUX
ADDR
12 U2 Sig.-
-25°C … +85°C
13 AS-i+
housing for DIN-rail mounting
14 AS-i-
99 mm, 22,5 mm, 92 mm
15 AUX+
housing IP20
16 AUX-
U1
U2
U1
U2
Sig+ Sig– Sig+ Sig–
ASI+ ASI– AUX+ AUX–
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 64
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Analog Module: 2 analog Inputs
• by supply out of AS-i: 50 mA max.
• by external supply: 500 mA max. (750 mA fuse)
Attention: no PE connection at 24 V aux. supply!
Code-Definition
ID1
14 bit
12 bit
Channel 1
0; 2; 3
1
4; 5; 7
(Default value ID1=7)
6
Channel 1+2
AS-i-Master/Gateways/
Links/Scanner
Supplying external loads:
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU1897 can transfer either 12 or 14-bit values.
Via ID1 the data capacity and the channel number can be defined.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 65
AS-i Analog Module: 2 analog Inputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
2 analog Inputs
in one module:
• 4 … 20 mA and 0 … 10 V (BWU1345, BWU1726)
• 4 … 20 mA and 1 … 5 V (BWU1447)
Profile 7.3 "Plug and Play" as simple as digital AS-i I/O
Protection category IP20
Article no. BWU1345
Article no. BWU1447: SIEMENS scaling
Article no. BWU1726: Default power supply 24 V external
The analog module has 2 analog inputs.
The connection of sensors is made by Combicon clamps. Current or
voltage modules can be attached over different clamps. The current
supply of the sensors can take place depending upon position of a
slide switch from AS-i or from external voltage (after PELV). With the
help of a 2. slide switch the 2. channel in favor of faster data commu-
Article no.
2 inputs
Voltage supply, sensors
Other Fieldbuses/
Master Simulators
4 … 20 mA
(BWU1345 BWU1447 BWU1726)
0 … 10 V (BWU1345 BWU1726)
1 … 5 V (BWU1447)
via AS-i/extern
via AS-i/extern
100 kΩ
Internal resistance
50 Ω
40 mA
–
Max. input voltage
–
25 V
Range of value
AS-i Safety
BWU1345 BWU1447 BWU1726
Max. input current
Resolution
16 bit/1 μA
16 bit/1 mV
4000 … 20000 dec.
(BWU1447: 0 ... 27648 dec.)
0 … 10000 dec.
(BWU1447: 0 ... 27648 dec.)
AS-i Profile
7.3
ID Code
3hex
ID2 Code
Dhex
IO Code
7hex
Displays
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (AUX)
voltage supply 24 V for the analog part
LED green (INT)
voltage supply for the analog part out of AS-i
Programming:
(Bit-setting of AS-i parameters)
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
Bit P1:
1: channel 2 is projected
0: channel 2 is not projected
Bit P2:
1: peripheral fault (e. g. broken wire to
the sensor) is indicated
0: peripheral fault (e. g. broken wire to
the sensor) is not indicated
Bit P3 (BWU1447):
not used
Bit P3 (BWU1345, BWU1726):
1: normal operating mode
0: both channels in current mode and
without recognition of wire break
Connections:
LED green (Analog 1)
state of channel 1
1
I1 Sig.+
LED green (Analog 2)
state of channel 2
2
I1 Sig.-
LED green (Analog 1)
channel 1:
LED on: current measurement,
LED off: voltage measurement
3
24 V ext.
4
0 V ext.
LED green (Analog 2)
channel 2:
LED on: current measurement,
LED off: voltage measurement
5
I2 Sig.+
6
I2 Sig.-
7
24 V ext.
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
8
0 V ext.
≥ 500 V
9
U1 Sig.+
Voltage of insulation
EMC directions
EN 50 081-2, EN 61 000-6-2
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Price Lists
nication can be switched off. The position of the slide switches is indicated over LEDs.
The conversion of the measured value and the data transmission via
AS-i occurs asynchronically according to AS-i Profile 7.3. The resolution of the analog data is 16 bit. The analog modules contains 50 Hz
and 60 Hz filters. These filters can be optionally activated with the
help of the AS-i parameters.
10 U1 Sig.-
0°C … +70°C
11 U2 Sig.+
-25°C … +85°C
12 U2 Sig.-
housing for DIN-rail mounting
13 AS-i+
99 mm, 22,5 mm, 92 mm
14 AS-i-
Protection category (DIN 40 050)
Supplying external loads:
by supply out of AS-i: 50 mA max.
by external supply: 500 mA max. (750 mA fuse)
housing IP20
15 AUX+
I1
I1
Sig+ SigI2
I2
Sig+ Sig-
–
OK
24V
ext.
24V
ext.
0V
ext.
0V
ext.
Input
1 2 1 2
Fault
Pwr
U
I
Int
Aux
Addr
Art. no.: 1345
U2
U2
U1
U1
Sig+ Sig- Sig+ SigAS-i+ AS-i- Aux+ Aux-
16 AUX-
Attention: no PE connection at 24 V aux. supply!
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 66
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module: 2 analog outputs
0 … 20 mA and 0 … 10 V
variable in one module
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
Protection category IP20
Article no. BWU1412
Article no. BWU1727: Default power supply 24 V external
2 outputs 0 … 20 mA
default via AS-i/extern
50 Ω
16 bit/1 μA
0 … 20000 dec.
7.3
3hex
ID2 Code
5hex
IO Code
7hex
Displays
LED green (PWR)
LED red (FAULT)
LED green (AUX)
LED green (INT)
LED green (Analog 1)
LED green (Analog 2)
LED green (Analog 1)
LED green (Analog 2)
Operating current
Operating voltage
Voltage of insulation
EMC directions
2 outputs 0 … 10 V
default extern
100 kΩ
16 bit/1 mV
0 … 10000 dec.
AS-i voltage
AS-i communication error, peripheral fault
voltage supply 24 V for the analog part
voltage supply for the analog part out of AS-i
State of channel 1
State of channel 2
channel 1: LED on: 0 … 20 mA, LED off: 0 … 10 V
channel 2: LED on: 0 … 20 mA, LED off: 0 … 10 V
< 80 mA
AS-i (30 V DC)
≥ 500 V
EN 50 081-2
EN 61 000-6-2
Ambient operating temperature
0°C … +70°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
99 mm, 22,5 mm, 92 mm
Protection category (DIN 40 050)
housing IP20
Attention:
no PE connection at 24 V aux. supply!
Programming:
(Bit-setting of AS-i parameters)
Bit P0:
1: Automatic mode recognition
0: Parameter bits P1, P3 define the
mode of channel 1 and 2
Bit P1: Channel 1 is a
1: Current module
0: Voltage module
Bit P2:
1: Peripheral fault (e. g. broken wire to
the sensor) is indicated
0: Peripheral fault (e. g. broken wire to
the sensor) is not indicated
Bit P3: Channel 2 is a
1: Current module
0: Voltage module
Connections:
1
I1 Sig.+
2
I1 Sig.3
24 V ext.
4
0 V ext.
5
I2 Sig.+
6
7
8
9
10
11
12
13
14
15
16
I2 Sig.24 V ext.
0 V ext.
U1 Sig.+
U1 Sig.U2 Sig.+
U2 Sig.AS-i+
AS-iAUX+
AUX-
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 67
Other Fieldbuses/
Master Simulators
Outputs
Voltage supply, actuators
Internal resistance
Resolution
Range of value
AS-i Profile
ID Code
BWU1412/BWU1727
AS-i Safety
Article no.
voltage (after PELV). The position of the slide switch is indicated
over LEDs.
The conversion of the measured value and the data transmission
via AS-i occurs asynchronically according to AS-i Profile 7.3. The
resolution of the analog data is 16 bit.
Price Lists
The analog module has 2 analog outputs.
The connection of actuators is made by COMBICON clamps.
Current or voltage modules can be attached over different
clamps. The current supply of the actuators can take place depending upon position of a slide switch from AS-i or from external
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
2 analog outputs
AS-i Analog Module:
2 analog Outputs for ± 10 V
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i-Analog Module
2 analog Outputs for ± 10 V
Galvanical separation to AS-i and AUX
Protection category IP20
Article no. BWU2224 for ± 10 V
The analog module has 2 analog outputs. The connection of actuators is made by COMBICON clamps. The outputs are short
circuit. The output channels have a common reference potential.
The actuators are controlled from separate 24 V and they are gal-
Article no.
vanically isolaed from AS-i and AUX. The conversion of the
measured value and the data transmission via AS-i occurs asynchronically according to AS-i Profile 7.3. The resolution of the analog data is 16 bit.
BWU2224
Connection
COMBICON clamp
AS-i Profile
S-7.3.5, ID1 = F (default)
AS-i voltage
18 ... 31,6 V
Max. AS-i current consumption 100 mA
AUX voltage
18 ... 30 V
Max. AUX current consumption 100 mA max.
Outputs
Programming:
(Bit-setting of AS-i parameters)
Bit P2:
1: Peripheral fault is indicatet
0: Peripheral fault is not indicatet
Bit P0, P1, P3:
not used
2 analog outputs ± 10 V
Max. output current
10 mA
Connections:
Resistance of the actuator
min. 1 kOhm
1
nc
nc
nc
Resolution
16 bit
2
nc
nc
nc
Range of value
-10000 ... +10000 dec.
3
24 V ext.out
Indicator
4
0 V ext.out
LED green (PWR)
AS-i voltage ON
5
nc
LED red(FAULT)
LED on: AS-i communication error,
LED blinking: peripheral fault
6
nc
7
24 V ext.out
LED green (AUX)
Voltage supply 24 V for the analog part
8
0 V ext.out
LED yellow (1)
State of channel 1
9
U1 Sig.+
LED yellow (2)
State of channel 2
10
U1 Sig.-
Applied standards
EN 50 081-2, EN 61 000-6-2
11
U2 Sig.+
Operating temperature
0°C … +60°C
12
U2 Sig.-
Storage temperature
-20°C … +85°C
13
AS-i+
Protection class DIN 40 050
Housing IP20
14
AS-i-
Dimensions (L / W / H in mm)
105 / 22,5 / 114
15
AUX+
Weight
-
16
AUX-
ext.in
ext.in
U1 Sig.- und U2 Sig.- are connected.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Power supply of analog outputs via 24 V ext. (AUX)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 68
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module: 4 analog Inputs
AS-i-Master/Gateways/
Links/Scanner
4 analog Inputs
Galvanical separation to AS-i
4 … 20 mA
0 … 10 V
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
Article no. BWU1364 for 4 … 20 mA
Article no. BWU1365 for 0 … 10 V
The analog module has 4 analog inputs.
The connection of the sensors is made by Combicon clamps. The
current supply of the sensors can be made out of AS-i or an external voltage supply (according to PELV). The current supply
switches automatically to the supply out of external voltage supply, as soon as an external voltage is connected.
The analog sensors and AS-i are galvanically separated.
The conversion of the measured value and the data transmission
via AS-i occurs asynchronically according to AS-i Profile 7.3.
The resolution of the analog data is 16 bit. The analog modules
contains 50 Hz and 60 Hz filters. These filters can be optionally
activated with the help of the AS-i parameters.
Article no.
BWU1364
BWU1365
4 inputs 4 … 20 mA
4 inputs 0 … 10 V
via AS-i/extern
50 Ω
100 kΩ
Max. input current
40 mA
–
Max. input voltage
–
25 V
16 bit/1 μA
16 bit/1 mV
Resolution
Range of value
4000 … 20000 dec.
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
Bit P1 and P2:
0 … 10000 dec.
Analog input is
AS-i Profile
7.3
P1
P2
1
2
3
4
ID Code
3hex
0
0
on
off
off
off
ID2 Code
Ehex
0
1
on
on
off
off
IO Code
7hex
1
0
on
on
on
off
1
1
on
on
on
on
LED green (AS-i)
AS-i voltage
1
1
on
on
on
on
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (AUX)
voltage supply 24 V for the analog part
Displays
LED yellow(DIAG)
diagnosis
LED yellow (I1)
state of channel 1
LED yellow (I2)
state of channel 2
LED yellow (I3)
state of channel 3
LED yellow (I4)
state of channel 4
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L / W / H in mm)
Protection category (DIN 40 050)
Other Fieldbuses/
Master Simulators
via AS-i/extern
Internal resistance
Bit P3:
1: Peripheral fault (e. g. broken wire to
the sensor) is indicated
0: Peripheral fault (e. g. broken wire to
the sensor) is not indicated
I1
24V
ext. Sig+
0V
ext.
I1
Sig-
I1
24V
ext. Sig+
0V
ext.
I1
Sig-
I2
24V
ext. Sig+
0V
ext.
I2
Sig-
I2
24V
ext. Sig+
0V
ext.
I2
Sig-
I3
24V
ext. Sig+
0V
ext.
I3
Sig-
I3
24V
ext. Sig+
0V
ext.
I3
Sig-
I4
Sig-
I4
24V
Sig+ ext.
I4
Sig-
I4
24V
Sig+ ext.
AS-i Safety
Voltage supply, sensors
(Bit-setting of AS-i parameters)
≥ 500 V
EN 50 081-2
EN 61 000-6-2
0°C … +70°C
-20°C … +85°C
housing for DIN-rail mounting
105 / 22,5 / 114
housing IP20
0V
ext.
AS-i+ AS-i- Aux+ Aux-
0V
ext.
AS-i+ AS-i- Aux+ Aux-
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 69
Price Lists
Inputs
Programming:
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP20
AS-i Analog Module: 4 analog Outputs
AS-i Master/Gateways/
Links/Scanner
4 analog Outputs
Galvanical separation to AS-i
0 … 20 mA
0 … 10 V
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP20
Article no. BWU1366 for 0 … 20 mA
Article no. BWU1367 for 0 … 10 V
The analog module has 4 analog outputs.
The connection of the actuators is made by Combicon clamps.
The current supply of the actuators can made out of AS-i or an
external voltage supply (according to PELV). The current supply
switches automatically to the supply out of external voltage supply, as soon as an external voltage is connected.
The actuators and AS-i are galvanically separated.
The conversion of the measured value and the data transmission
via AS-i occurs asynchronically according to AS-i Profile 7.3.The
resolution of the analog data is 16 bit.
Article no.
BWU1366
BWU1367
4 outputs 0 … 20 mA
4 outputs 0 … 10 V
via AS-i/extern
via AS-i/extern
50 Ω
100 kΩ
Inputs
Voltage supply, actuators
Internal resistance
Resolution
Range of value
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Profile
16 bit/1 μA
16 bit/1 mV
0 … 20000 dec.
0 … 10000 dec.
7.3
ID Code
3hex
ID2 Code
6hex
IO Code
7hex
Displays
LED green (AS-i)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (AUX)
voltage supply 24 V for the analog part
LED yellow(DIAG)
diagnosis
LED yellow (O1)
state of channel 1
LED yellow (O2)
state of channel 2
LED yellow (O3)
state of channel 3
LED yellow (O4)
state of channel 4
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
(Bit-setting of AS-i parameters)
Bit P0:
1: Profile 7.3 is monitored
0: Profile 7.3 is not monitored
Bit P1, P3:
not used
Bit P2:
1: Peripheral fault (e. g. broken wire to
the sensor) is indicated
0: Peripheral fault (e. g. broken wire to
the sensor) is not indicated
24V O1
ext. Sig+
0V
ext.
O1
Sig-
24V O1
ext. Sig+
0V
ext.
O1
Sig-
24V O2
ext. Sig+
0V
ext.
O2
Sig-
24V O2
ext. Sig+
0V
ext.
O2
Sig-
24V O3
ext. Sig+
0V
ext.
O3
Sig-
24V O3
ext. Sig+
0V
ext.
O3
Sig-
O4
Sig-
O4 24V
Sig+ ext.
O4
Sig-
O4 24V
Sig+ ext.
≥ 500 V
EN 50 081-2, EN 61 000-6-2
0°C … +70°C
-20°C … +85°C
housing for DIN-rail mounting
0V
ext.
0V
ext.
105 mm, 22,5 mm, 114 mm
housing IP20
AS-i+ AS-i- Aux+ Aux-
AS-i+ AS-i- Aux+ Aux-
Price Lists
Protection category (DIN 40 050)
Programming:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 70
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module: 4 Pt100 Inputs
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
Protection category IP20
Article no. BWU1368
Article no.
transmission via AS-i occurs asynchronically according to AS-i
Profile 7.3.
The resolution of the analog data is 16 bit. The analog modules
contains 50 Hz and 60 Hz filters. These filters can be optionally
activated with the help of the AS-i parameters.
BWU1368
Inputs
4 Pt100 inputs
Voltage supply, sensors
via AS-i/extern
Internal resistance
50 Ω
Resolution
16 bit/0,1 °C
Range of value [°C]
-200°C … +850°C
AS-i Profile
7.3
ID Code
3hex
Programming:
(Bit-setting of AS-i parameters)
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
Bit P1 and P2:
A peripheral fault can be released
through channel:
ID2 Code
5hex
P1
P2
1
2
3
4
IO Code
7hex
0
0
yes
no
no
no
0
1
yes yes
no
no
LED green (AS-i)
AS-i voltage
1
0
yes yes yes
no
LED red (FAULT)
AS-i communication error, periphal fault
1
1
yes yes yes yes
LED yellow (I1)
state of channel 1
LED yellow (I2)
state of channel 2
LED yellow (I3)
state of channel 3
Displays
LED yellow (I3)
state of channel 4
Bit P3:
1: 2-wire mode
0: 4-wire mode
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
CH1 CH1 CH1
S+
+
-
Voltage of insulation
≥ 500 V
CH2
S+
EN 50 081-2, EN 61 000-6-2
Ambient operating temperature
0°C … +70°C
Storage temperature
-20°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
105 mm, 22,5 mm, 114 mm
Protection category (DIN 40 050)
housing ip20
FE
FE
FE
CH1
S-
CH2 CH2 Ch2
S+
AS-i Safety
EMC directions
FE
CH3 CH3 CH3
S+
CH4 CH4
S-
CH3
S+
CH4 CH4
S+
+
AS-i+ AS-i-
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 71
Price Lists
The analog module has 4 Pt100 inputs.
The connection of the sensors is made by Combicon clamps. By
supply out of AS-i the analog sensors are galvanical seperated to
the AS-i. The conversion of the measured value and the data
Other Fieldbuses/
Master Simulators
Galvanical separation to AS-i
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
4 Pt100 Inputs
AS-i Analog Module:
4 thermocouple type J resp. K inputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
4 thermocouple type J resp. K inputs
Galvanical separation to AS-i
Profile 7.3 "Plug and Play"
as simple as digital AS-i I/O
Protection category IP20
Article no. BWU1933: 4 thermocouple type J
Article no. BWU2243: 4 thermocouple type K
The analog module has 4 thermocouple type J resp. K inputs.
The connection of the sensors is made by Combicon clamps. The
temperature is measured using cold junction temperature compensation. The analog sensors are galvanical separated to AS-i.
The resolution of the analog data is 16 bit. The analog modules contain 50 Hz and 60 Hz filters. These filters can be optionally activated
with the help of the AS-i parameters.
Article no.
Inputs
Voltage supply, sensors
Internal resistance
Resolution
AS-i Safety
Other Fieldbuses/
Master Simulators
Range of value [°C]
For internal compensation the peripheral fault can be caused by a
broken wire of the thermocouple. For the external compensation
(Pt100 in connectors 2 and 3) the peripheral fault can also be caused
by a broken wire or a short circuit of the Pt100 element. A short circuit
of the TC cannot be recognised as an error.
Programming:
(Bit-setting of AS-i parameters)
4 thermocouple type J resp. K inputs
via AS-i/extern
1 MΩ
16 bit/0,1 °C
-200°C … +760°C
Bit P0
1: 50 Hz filter in A/D converter active
0: 60 Hz filter in A/D converter active
Bit P1 and P2: peripheral faults caused by
AS-i Profile
7.3
P2
P1
ch. 1 ch. 2
ID Code
3hex
0
0
on
off
off
off
ID2 Code
Ehex
0
1
on
on
off
off
IO Code
7hex
Displays
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral
fault
LED yellow (In 1)
state of channel 1
LED yellow (In 2)
state of channel 2
LED yellow (In 3)
state of channel 3
LED yellow (In 4)
state of channel 4
Operating current
< 100 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category
(DIN 40 050)
Price Lists
BWU1933 / BWU2243
The conversion of the measured value and the data transmission via
AS-i occur asynchronically according to the AS-i Profile 7.3.
≥ 500 V
EN 61 000-6-2, EN 61 000-6-4
0°C … +70°C
1
0
on
on
on
off
1
1
on
on
on
on
Bit P3
0: selects external compensation
1: selects internal compensation
Terminal connections:
FE
FE
FE
FE
TC1+ PT1+ PT1- TC1TC2+ PT2+ PT2- TC2-
–
OK
Pwr Fault
Addr
105 mm, 22,5 mm, 116 mm
housing IP20
Note:
Precise cold junction compensation requires vertical mounting and natural air circulation. A clearance of at least 5 cm each side is required!
FE
funtional earth
TCx± thermo element +/– (inputs 1 - 4)
PTx± PT100 +/– (external compensation)
AS-i± AS-Interface +/–
Input
1 2 3 4
-25°C … +85°C
housing for DIN-rail mounting
ch. 3 ch. 4
www.bihl-wiedemann.com
NC
not connected
The inputs ch. 2, ch. 3
and ch 4 are connected
FE FE FE FE
with a bridge and a resisTC1+ PT1+ PT1- TC1tor (in default state) to
TC2+ PT2+ PT2- TC2become a valid input
value and to avoid peripheral faults.
This can also be obtained by setting the
paramater P1, P2.
100 Ω
TC3- PT3- PT3+ TC3+
TC4- PT4- PT4+ TC4+
ASI+ ASI- NC NC
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 72
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module: 2 analog Inputs
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
Article no. BWU1232 for 4 … 20 mA
Article no. BWU1233 for 0 … 10 V
plied by AS-i or external voltage (according to PELV) via the black
ribbon cable. The resolution of the analog data is 16 bit. The analog modules contain 50 Hz and 60 Hz filters. These filters can
be optionally activated with the help of the AS-i parameters.
Article no.
Inputs
Voltage supply, sensors
BWU1232
BWU1233
2 inputs 4 … 20 mA
2 inputs 0 … 10 V
via AS-i/extern
via AS-i/extern
Internal resistance
50 Ω
100 kΩ
Max. input current
40 mA
–
Max. input voltage
–
25 V
16 bit/1 μA
16 bit/1 mV
Resolution
Range of value
4000 … 20000 dec.
0 … 10000 dec.
AS-i Profile
7.3
ID Code
3hex
ID2 Code
Dhex
IO Code
7hex
Displays
LED green (analog 1)
analog signal1
LED green (analog 2)
analog signal2
LED green (AUX)
power on
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
≥ 500 V
Voltage of insulation
EMC directions
EN 50 081-2, EN 61 000-6-2
Ambient operating temperature
0°C … +70°C
Storage temperature
Programming:
(Bit-setting of AS-i parameters)
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
Bit P1:
1: Channel 2 is projected
0: Channel 2 is not projected
Bit P2:
1: Peripheral fault (e. g. broken wire to the
sensor) is indicated
0: Peripheral fault (e. g. broken wire to the
sensor) is not indicated
Bit P3:
not used
Accessories:
AS-i substructure module to connect 1 AS-i
flat cable, 1 flat cable for additional supply
(Art. no. BW1181, see also page 183)
AS-i substructure module to 1 AS-i round
cable, 1 round cable for additional supply
(Art. no. BW1183, see also page 183)
-25°C … +85°C
Housing
housing for DIN-rail mounting
Case connector
2*M16x1,5, 1*M12x1,5
Dimensions (L, W, H)
90 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
housing IP65
AS-i Safety
The analog modules have 2 analog inputs. The conversion of the
measured value and the data transmission via AS-i occurs asynchronically according to AS-i Profile 7.3. 2 analog sensors can be
connected via cage clamp terminals. The sensors can be sup-
Other Fieldbuses/
Master Simulators
4 … 20 mA
0 … 10 V
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
2 analog Inputs
Connections:
1
24V ext.
7
24V ext.
2
Sig.+ Ch2
8
Sig.+ Ch1
3
0V ext.
9
0V ext.
4
Sig.- Ch2
10 Sig.- Ch1
5
Shield
11 FG
6
Shield
12 FG
Cage clamp terminals
LEDs
1 2 3 4 5 6
7 8 9 10 11 12
FG: Function ground
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 73
Price Lists
Jumper
AS-i Analog Module: 2 analog Outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
2 analog Outputs
0 … 20 mA
0 … 10 V
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
Article no. BWU1234 for 0 … 20 mA
Article no. BWU1235 for 0 … 10 V
connected via cage clamp terminals. The actuators can be supplied by AS-i or external voltage (according to PELV) via the black
ribbon cable. The resolution of the analog data is 16 bit.
The analog modules have 2 analog outputs. The digital-analog
conversion and the data transmission via AS-i occurs asynchronically according to AS-i Profile 7.3. 2 analog actuators can be
Article no.
Outputs
Voltage supply
BWU1234
BWU1235
2 outputs 0 … 20 mA
2 outputs 0 … 10 V
via AS-i/extern
via AS-i/extern
Output limit
Resolution
Range of value
16 bit/1 μA
16 bit/1 mV
0 … 20000 dec.
0 … 10000 dec.
AS-i Profile
7.3
ID Code
3hex
ID2 Code
5hex
IO Code
7hex
Other Fieldbuses/
Master Simulators
Displays
LED green (Analog 1)
analog signal 1
LED green (Analog 2)
analog signal 2
LED green (AUX)
Power on
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
≥ 500 V
Voltage of insulation
EMC directions
EN 50 081-2, EN 61 000-6-2
Ambient operating temperature
0°C … +70°C
Storage temperature
Bit P0:
not used
Bit P1:
not used
Bit P2:
1: Peripheral fault (e. g. broken wire to the
sensor) is indicated
0: Peripheral fault (e. g. broken wire to the
sensor) is not indicated
Bit P3:
not used
Accessories:
AS-i substructure module to connect 1 AS-i
flat cable, 1 flat cable for additional supply
(Art. no. BW1181, see also Seite 183)
AS-i substructure module to 1 AS-i round
cable, 1 round cable for additional supply
(Art. no. BW1183, see also Seite 183)
-25°C … +85°C
Housing
AS-i Safety
Programming:
(Bit-setting of AS-i parameters)
housing for DIN-rail mounting
Case connector
2*M16x1,5, 1*M12x1,5
Dimensions (L, W, H)
90 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
housing IP65
Connections:
1
24 V ext.
7
24 V ext.
2
Sig.+ Ch2
8
Sig.+ Ch1
3
0V ext.
9
0 V ext.
4
Sig.- Ch2
10 Sig.- Ch1
5
Shield
11 FG
6
Shield
12 FG
Price Lists
Cage clamp terminals
LEDs
1 2 3 4 5 6
7 8 9 10 11 12
Jumper
FG: Function ground
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 74
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module:
4 Pt100/Pt1000 Inputs
AS-i-Master/Gateways/
Links/Scanner
4 inputs Pt100 and Pt1000 respectively
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
BWU1509
4 Pt100 inputs
4 Pt1000 inputs
Supply
via AS-i/extern
Resolution/Bit
16 bit/0,1 °C
Measuring range [°C]
-200°C … +850°C
Programming:
(Bit-setting of AS-i parameters)
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
AS-i Profile
7.3
ID Code
3hex
Peripheral fault can be caused by chanel:
ID2 Code
Ehex
P1
P2
1
2
3
4
IO Code
7hex
0
0
yes
no
no
no
0
1
yes
yes
no
no
analog signal 1
1
0
yes
yes
yes
no
LED green (Analog 2)
analog signal 2
1
1
yes
yes
yes
yes
LED green (Analog 3)
analog signal 3
Displays
LED green (Analog 1)
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (Analog 4)
analog signal 4
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
≥ 500 V
Voltage of insulation
EMC directions
0°C … +70°C
Storage temperature
-25°C … +85°C
housing for DIN-rail mounting
Case connector
Accessories:
AS-i substruce module to connect 2 AS-i
flat cables (Art. no. BW1180, see also page 183)
AS-i substructure module to connect 2 AS-i
ound cables (Art. no. BW1182, see also
page 183)
8*M12x1,5
Dimensions (L, W, H)
90 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
Connections:
1 channel 1+
2 channel 1 Sense3 channel 1 4 channel 2 +
5 channel 2 Sense6 channel 2 7 channel 3 +
8 channel 3 Sense9 channel 3 10 channel 4 +
11 channel 4 Sense12 channel 4 -
Bit P3:
1: 2-wire mode
0: 3-wire mode
EN 50 081-2, EN 61 000-6-2
Ambient operating temperature
Housing
Bit P1 and P2:
housing IP65
Cage clamp terminal
LEDs
AS-i Safety
Inputs
BWU1254
1 2 3 4 5 6
7 8 9 10 11 12
1, 4, 7, 10 are internally connected
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 75
Price Lists
Article no.
terminals. The sensors can be supplied by AS-i. The resolution of
the analog data is 16 bit/0,1°C. The Pt100/Pt1000 module contains 50 Hz and 60 Hz filters. These filters can be optionally activated with the help of the AS-i parameters.
Other Fieldbuses/
Master Simulators
The analog modules have 4 Pt100 inputs and 4 Pt1000 inputs
respectively. The conversion of the measured value and the data
transmission via AS-i occurs asynchronically according to AS-i
Profile 7.3. 4 analog sensors can be connected via cage clamp
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BWU1254: 4 Pt100 Inputs
Article no. BWU1509: 4 Pt1000 Inputs
AS-i-Master/Gateways/
Links/Scanner
AS-i Analog Module:
2 Pt100 Inputs + 2 Relais Outputs
2 Pt100 Inputs + 2 Relais Outputs
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
AS-i-Zubehör/Diagnose/
Entwicklung
AS-i-Slaves
Article no. BW1552
The analog module has 2 Pt100 inputs and 2 relais outputs. The
conversion of the measured value and the data transmission via
AS-i occurs asynchronically according to AS-i Profile 7.3. 2 analog sensors can be connected via cage clamp terminals. The
sensors can be supplied by AS-i. The resolution of the analog
Article no.
BW1552
Inputs
2 Pt100 inputs
Outputs
2 relais outputs
Supply
via AS-i/extern
Resolution/Bit
16 bit/0,1 °C
Measuring range [°C]
-200°C … +850°C
AS-i Profile
7.3
ID Code
3hex
ID2 Code
Dhex
IO Code
7hex
data is 16 bit/0,1°C. The Pt100 module contains 50 Hz and 60 Hz
filters. These filters can be optionally activated with the help of the
AS-i parameters.
The relais outputs are galvanically isolated SPDT Reed-relais.
They are switched with parameter bits P2 and P3.
Programming:
(Bit-stting of AS-i parameters)
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
Bit P1:
1: 2-wire mode
0: 3-wire mode
Bit P2:
0: Relais 1 on
1: Relais 1 off
Sonstige Feldbusse/
Mastersimulatoren
Displays
LED green (Analog 1)
analog signal 1
LED green (Analog 2)
analog signal 2
LED yellow (Rel 1)
relais 1
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED yellow (Rel 2)
relais 2
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
≥ 500 V
AS-i-Sicherheit
Accessories:
AS-i substructure module to connect 2 AS-i flat
cables (Art. no. BW1180, see also Seite 183)
AS-i substructure module to connect 2 AS-i round
cables (Art. no. BW1182, see also Seite 183)
Relais
SPDT, max 50 V, max. 0.5 A
EMC directions
EN 50 081-2, EN 61 000-6-2
Ambient operating temperature
Preislisten
Bit P3:
0: Relais 2 on
1: Relais 2 off
0°C … +70°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Case connector
8*M12x1,5
Dimensions (L, W, H)
90 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
housing IP65
Connections:
1 channel 1+
7
2
channel 1 Sense-
8
relais 1 - COM
3
channel 1 -
9
relais 1 - NC
4
channel 2 +
10 relais 2 - NO
5
channel 2 Sense-
11 relais 2 - COM
6
channel 2 -
12 relais 2 - NC
relais 1 - NO
Cage clamp terminal
LEDs
1 2 3 4 5 6
7 8 9 10 11 12
1 and 4 are internally connected
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Tel.: 0621/33996-0 · Fax: 0621/3392239 · eMail: mail@bihl-wiedemann.de
Seite 76
Mannheim, 29.3.11
Angaben ohne Gewähr
www.bihl-wiedemann.de
AS-i Balance Controller
AS-i-Master/Gateways/
Links/Scanner
AS-i Balance Controller
AS-i connection for a 6-wire load cell
Weights directly via AS-i
Tara via AS-i parameter
Article no.
Accessories:
Windows software for calibration
BW2240
Inputs
1 load cell
Sensor supply
via AS-i
Resolution
16 bit
Range of values
adjustable
AS-i Profile
7.5.5
ID Code
3hex
ID2 Code
Chex
IO Code
7hex
Calibration Master (art. no. BW1728)
AS-i substructure module to connect 2 AS-i flat
cable (art. no. BW1180, page 183)
AS-i substructure module to connect 2 AS-i
round cable (art. no. BW1182, page 183)
Software "AS-i Control-Tools" (art. no. BW1203,
page 48)
Displays
LED yellow (CAL)
calibration
LED green (IN)
load cell connected
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
Software "AS-i Control-Tools" with serial transmission cord for AS-i Master in Stainless Steel
(art. no. BW1602, page 48)
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
AS-i Parameter
Voltage of insulation
≥ 500 V
0
Set tara
EMC
according to EN 50 081-2, EN 61 000-6-2
1
Delete tara
0°C … +70°C
B
Filter 4 s
Storage temperature
-25°C … +85°C
C
Filter 3 s
Housing
housing for DIN-rail mounting
D
Filter 2 s
Case connector
2*M16x1,5, 1*M12x1,5
E
Filter 1 s
Dimensions (L / W / H in mm)
90 / 80 / 70
F
No filter
Ambient operating temperature
Protection category (DIN 40 050) housing
Connections
Pin
Connection
1, 7
Supply +
2, 8
Sensor line +
3, 9
Output +
Switch 1:
Normal operation
Other Fieldbuses/
Master Simulators
The 6-wire load cells are connected directly via heavy gauge terminals onto a cage clamp block in the AS-i load cell controller.
The AS-i load cell controller is located in a robust IP65 housing
and can so be mounted near to the load cell. Longer wires
between cells and controller can be avoided. The calibration is
executed with the help of AS-i Control Tools and any AS-i 3.0
Bihl+Wiedemann Master. With the calibration on 2 points of reference the average value of 50 measurements is formed. The
output for a reference weight can be set likewise simply with the
help of the Windows software. As long as the scales controller
was not calibrated on a load cell, the expenditure of the measured values takes place in mV/V (1 mV/V corresponds to
5000 decimally).
AS-i Safety
The AS-i Balance Controller allows the connection of a load cell
to AS-i. The weight will be transfered as 16 bits analog value . Via
AS-i the weight is available to nearly all controls as 16 bits value.
The setting and deleting of tara is made with the help of 2 AS-i
parameters. The tara value is stored remanent.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW2240: Calibration with AS-i Control Tools
cage clamp block
LEDs
1 2 3 4 5 6
7 8 9 10 11 12
ON
1
4, 10 Output dip switch
6, 12 Supply -
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 77
Price Lists
5, 11 Sensor line-
AS-i 3.0 Analog Module:
2 analog Inputs (M12)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
2 analog inputs, either 4 ... 20 mA or 2 Pt100 inputs
Infrared interface for slave addressing
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
Article no. BWU1893: 2 inputs 4 ... 20 mA on AS-i with M12 connectors in IP65, AS-i 3.0 AB Slave
Article no. BWU1894: 2 inputs 4 ... 20 mA on AS-i with M12 connectors in IP65, AS-i 2.1 Single Slave
Article no. BWU1895: 2 inputs Pt100 on AS-i with M12 connectors in IP65, AS-i 3.0 AB Slave
Article no. BWU2086: see BWU1895, second input via ID1 deactivated
Article no. BWU2050: 2 inputs Pt100 on AS-i with M12 connectors in IP65, AS-i 2.1 Single Slave
Measured values are transfered sequentially to the host according to the respective AS-i profile. The resolution of the analog
data is either 11 bit or 14 bit.
The analog module has 2 analog inputs, either 4 ... 20 mA or 2
Pt100 inputs.
M12 connectors connect sensors to the analog module. The current supply of the sensors is made out of AS-i.
Article no.
Inputs
BWU1893
BWU1894
BWU1895
BWU2050
2 inputs Pt100
second input via
ID1 deactivated
AS-i Specification
AS-i 3.0 AB Slave
AS-i 2.1 Single
Slave
AS-i 3.0 AB Slave
Sensor supply
Max. current per input
Resolution
Range of value
82 Ω
–
40 mA
–
regular: 14 bit; fast: 11 bit
14 bit
4000 … 20000 dec.
0 ... 27648 dec.
Measuring value
Transformation speed
AS-i 2.1 Single Slave
via AS-i
Internal resistance
Other Fieldbuses/
Master Simulators
BWU2086
2 inputs 4 … 20 mA
16 bit
-2000 ... 8500 dec.
-12000 ... 13000 dec.
4 ... 20 mA
-200 °C ... +850 °C/ 0,4 °C
-120 °C ... +130 °C/ 0,04 °C
regular: 33 ms/14 bit; fast: 4,2 ms/11 bit
-200 °C ... +850 °C/ 0,1 °C
-120 °C ... +130 °C/ 0,01 °C
240 ms
AS-i Profile
7.A.9
7.3.D
7.A.9
7.3.D
ID Code
Ahex
3hex
Ahex
3hex
ID1 Code
see code definition
table
Fhex
see code
definition table
Fhex
ID2 Code
9hex
Dhex
9hex
Dhex
IO Code
7hex
AS-i Safety
Displays
LED green (PWR)
LED on: voltage at the AS-i clamps
LED red (FAULT)
LED on: AS-i communication error
LED flashing: AS-i peripheral fault
LED yellow (state: In 1, In 2)
LED off: no signal or channel 2 is switched off (BW1894 only)
LED on: signal in the range of values
LED flashing: signal out of the range of values
Operating current
Operating voltage
Voltage of insulation
EMC directions
Price Lists
Ambient operating temperature
Storage temperature
Housing
< 200 mA
< 80 mA
AS-i (30 V DC)
≥ 500 V
EN 61 000-6-2, EN 61 000-6-4
0°C … +70°C
-20°C … +85°C
housing for DIN-rail mounting
Dimensions (L / W / H in mm)
80 / 45 / 24,5
Protection category DIN 40 050
housing IP65
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 78
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Analog Module:
2 analog Inputs (M12)
BWU1894
BWU1895
BWU2086
BWU2050
1: peripheral fault is indicated
0: peripheral fault is not indicated
Bit P1
1: 4000 … 20000 dec.
0: 0 ... 27648 dec. (Siemens format)
Bit P2
1: regular
0: fast
Bit P3
–
1: 2-wire mode
0: 4-wire mode
1: -200 °C ... +850 °C
0: -120 °C ... +130 °C
1: channel 2 on
0: channel 2 off
–
Code definition table for article no. BWU1893 and BWU1895
ID1
14 bit
12 bit
Channel 1
0; 2; 3
1
4; 5; 7
(default setting
ID1=7)
6
Channel 1+2
BWU1893 + BWU1895 can transfer either 12 bit or 14 bit values.
Via ID1 the data capacity and the channel number can be defined.
Accessories:
AS-i substructure module to connect 2 AS-i flat cables (article no. BW1180, see also page 183)
AS-i substructure module to connect 1 AS-i flat cable, 1 flat cable for additional supply (article no. BW1181, see also page 183)
AS-i substructure module to connect 2 AS-i round cable (article no. BW1182, see also page 183)
AS-i substructure module to connect 1 AS-i round cable, 1 round cable for additional supply (article no. BW1183, see also page 183)
AS-i substructure module to connect 2 AS-i flat cables with addressing socket (article no. BW1438, see also page 183)
Pinning:
BWU1893, BWU1894
BWU1895, BWU2086, BWU2050
1
24 V
1
2
Sig+
2
CHS+
3
0V
3
CH-
4
0V
4
CHS-
5
Shield
5
Shield
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
CH+
AS-i-Master/Gateways/
Links/Scanner
BWU1893
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Bit-setting of AS-i parameters
Bit P0
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 79
AS-i 3.0 Analog Module:
2 analog Inputs (M12)
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
2 analog inputs 0 ... 10 V
Infrared interface for slave addressing
Profile 7.A.9 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
Article no. BWU1963: 2 inputs 0 ... 10 V on AS-i with M12 connectors in IP65, AS-i 3.0 AB slave
Article no. BWU1964: 2 inputs 0 ... 10 V on AS-i with M12 connectors in IP65, AS-i 2.1 single slave
The analog module has 2 analog inputs 0 ... 10 V.
The connection of the sensors is made by M12 connectors. The
current supply of the sensors is made out of AS-i.
Article no.
BWU1963
Inputs
AS-i specification
BWU1964
AS-i 2.1 single slave
via AS-i
Max. supply current for sensors (sum)
70 mA
Resolution
11 resp.14 bit
Range of value
regular: 33 ms/14 bit, fast: 4,2 ms/11 bit
7.A.9
7.3.D
ID Code
Ahex
3hex
ID2 Code
9hex
Dhex
IO Code
7hex
7hex
Displays
LED green (PWR)
LED on: voltage at the AS-i clamps
LED red (FAULT)
LED on: AS-i communication error
LED flashing: AS-i peripheral fault
LED off: channel 2 is switched off
LED on: signal in the range of values
LED flashing: signal out of the range of values
Operating current
< 200 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
Price Lists
AS-i Safety
EMC directions
Ambient operating temperature
Storage temperature
Bit P0:
1: peripheral fault is indicated
0: peripheral fault is not indicated
Bit P1:
1: 0 … 10000 dec.
0: 0 ... 27648 dec. (Siemens format)
0 … 10000 dec.
0 ... 27648 dec.
AS-i Profile
LED yellow (state: In 1, In 2)
Programming:
(Bit-setting of AS-i parameters)
2 inputs 0 … 10 V
AS-i 3.0 AB slave
Sensor supply
Transformation speed
Measured values are transfered sequentially to the host according to the respective AS-i profile. The resolution of the analog
data is 11 resp. 14 bit.
≥ 500 V
EN 61 000-6-2, EN 61 000-6-4
0°C … +70°C
Bit P2:
1: regular transformation speed
0: fast transformation speed
BWU1964
Bit P3:
1: channel 2 on
0: channel 2 off
BWU1963
ID1:
14 bit
12 bit
channel 1:
0; 2; 3
1
channel 1+2: 4; 5 ; 7
6
(Default ID1=7)
BWU1963 can transfer 12 resp. 14 bits
of values. Via ID1 the data capacity
and the channel number can be
defined.
Pinning:
-20°C … +85°C
1
24 V
housing for DIN-rail mounting
2
Sig+
Dimensions (L / W / H in mm)
80 / 45 / 24,5
3
0V
Protection category DIN 40 050
housing IP65
4
Sig-
5
Shield
Housing
Accessories:
AS-i substructure module to connect 2 AS-i flat cables (article no. BW1180, see also Seite 183)
AS-i substructure module to connect 2 AS-i round cable (article no. BW1182, see also Seite 183)
AS-i substructure module to connect 2 AS-i flat cables with addressing socket (article no. BW1438, see also Seite 183)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 80
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Analog Module:
Analog Input and Output Module (M12)
AS-i-Master/Gateways/
Links/Scanner
1 analog Input/1 analog Output
4 … 20 mA or 0 … 10 V in one Module
Automatic switching between current and voltage
8, 12 or 16 transmitted bits
via 2, 3 or 4 AS-i slave address
Profile S-6.0.x
The analog module has 1 analog input and 1 analog output.
Current or voltage modules can be attached over M12 connectors. The module switches automatically over between current
and voltage depending upon the occupied socket.
The current supply is made out of an external voltage supply (according to PELV, by BWU1853) or out of AS-i (BWU1917).
The conversion of the measured value and the data transmission
via AS-i occurs according to AS-i Profile S-6.0.x. The resolution
of the analog data is 16 bit. The analog modules contains 50 Hz
and 60 Hz filters. These filters can be optionally activated with the
help of the AS-i parameters.
Optical addressing is not possible.
Article no.
BWU1917
24 V auxiliary on M12
24 V auxiliary on M12
1 A out of aux. 24 V 100 mA (In U) / 40 mA (In I)
out of AS-i
Outputs
0 .. 20 mA or 0 .. 10 V
Inputs
4 .. 20 mA or 0 .. 10 V
Max. input current or max. input voltage
Resolution
AS-i profile
Number of transmitted bits
Impedance
50 Ω or 100 kΩ
40 mA or 25 V
16 bit/1 μA or 16 bit/1 mV
S-6.0.x
IO code 6
ID code 0
ID1 code:
• The ID 1 code can be written for all slaves,
but only the slave with the lowest address
defines the code for the remaining slaves.
• The ID1 code is equal for all slaves.
• The ID2 code for all slaves (for each different according to the profile) is specified by
the ID1 code.
8, 12, 16
2 single slave loads
ID Code
0
ID2 Code
acc. to profile
IO Code
6hex
Number of associated AS-i slaves
ID1 = A: 2 AS-i slaves according to 8 bits
ID1 = B: 3 AS-i slaves according to 12 bits
else:
4 AS-i slaves according to 16 bits
Displays
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (AUX)
voltage supply 24 V for the analog part
LED yellow (In U)
state of channel input U
LED yellow (In I)
state of channel input I
LED yellow (Out U)
state of channel output U
LED yellow (Out I)
state of channel output I
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H in mm)
Protection category (DIN 40 050)
≥ 500 V
AS-i Safety
Internal resistance
Configuration notes
EN 61 000-6-2, EN 61 000-6-4
0°C .. +70°C
-20°C .. +85°C
housing for DIN-rail mounting
80 / 90 / 45
housing IP65
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 81
Price Lists
Supply
BWU1853
Other Fieldbuses/
Master Simulators
Article no. BWU1853: 1I/1O, 4 .. 20 mA or 0 .. 10 V (24 V auxiliary on M12)
Article no. BWU1917: 1I/1O, 4 .. 20 mA or 0 .. 10 V (supplied out of AS-i)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
High protection category IP65
AS-i 3.0 Analog Module:
Analog Input and Output Module (M12)
ID2 Codes
Adr n
2 slaves = 8 bits
Adr n+1
Socket allocation and pinning
Adr n+2
Adr n+3
A
5
-
-
3 slaves = 12 bits B
6
5
-
7
6
5
4 slaves = 16 bits C
Parameter (first address)
Parameter
Name
Description
P0
Auto/Fix
1: automatic switching between current and
voltage
0: current/voltage specified by P1
P1
Out U/I
If P0 = 0:
1: OutI active
0: OutU active else not used
P2
Peripheral fault 1: peripheral fault is indicated
0: peripheral fault is not indicated
P3
In U/I
Parameter
Name
P1, P0
Convertion rate 11: fastest: 1 ms/8 bits
InI, InU
01: medium fast/precise: 5 ms/12 bits
10: highest precision: 20 ms/16 bits
00: not used
P2
Format
1: 10 V = 10000, 20 mA = 20000
0: 10 V = 27648, 20 mA = 27648
(Siemens format)
P3
Bridge
1: Pin 3 and pin 4 bridged
0: Pin 3 and pin 4 not bridged
If P0 = 0:
1: InI active
0: InU active else not used
Parameter (second address)
Description
Accessories:
• AS-i substructure module to connect 2 AS-i flat cables (art. no. BW1180, see also Seite 183)
• AS-i substructure module to connect 1 AS-i flat cable, 1 flat cable for additional supply (art. no. BW1181, see also Seite 183)
• AS-i substructure module to connect 2 AS-i round cable (art. no. BW1182, see also Seite 183)
• AS-i substructure module to connect 1 AS-i round cable, 1 round cable for additional supply (art. no. BW1183, see also Seite 183)
• AS-i substructure module to connect 2 AS-i flat cables with addressing socket (art. no. BW1438, see also Seite 183)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Programming
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 82
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module:
4 analog Inputs (M12)
AS-i-Master/Gateways/
Links/Scanner
4 analog inputs on M12 socket
Galvanical isolation to AS-i
4 … 20 mA
0 … 10 V
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
Article no. BWU1359 for 4 … 20 mA
Article no. BWU2049 for 4 ... 20 mA, Siemens format
Article no. BWU1360 for 0 … 10 V
Article no. BWU1742 for 0 … 10 V, advanced temperature range: -20°C … +70°C
The analog module has 4 analog inputs.
M12 connectors connect sensors to the analog module. The sensors are powered out of AS-i or an external voltage supply (according to PELV). The current supply switches automatically to
the supply out of an external voltage supply, as soon as an external voltage is connected.
Inputs
BWU1359
BWU2049
BWU1360
4 inputs 4 … 20 mA
Voltage supply, sensors
BWU1742
4 inputs 0 … 10 V
via AS-i/extern
Internal resistance
50 Ω
Max. input current
40 mA
–
Max. input voltage
–
25 V
Resolution
Range of value
100 kΩ
16 bit/1 μA
4000 … 20000 dec.
16 bit/1 mV
0 ... 27648 dec.
(Siemens format)
0 … 10000 dec.
AS-i Profile
7.3
ID Code
3hex
ID2 Code
Ehex
IO Code
7hex
Other Fieldbuses/
Master Simulators
Article no.
The analog sensors are galvanically isolated to AS-i.
The conversion of the measured value and the data transmission
out of AS-i occurs asynchronically according to the AS-i Profile
7.3. The resolution of the analog data is 16 bit.
With infrared interface for slave addressing.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
High protection category IP65
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (AUX)
voltage supply 24 V for the analog part
LED yellow (In 1)
state of channel 1
LED yellow (In 2)
state of channel 2
LED yellow (In 3)
state of channel 3
LED yellow (In 4)
state of channel 4
Operating current
< 200 mA
Operating voltage
AS-i (30 V DC)
≥ 500 V
Voltage of insulation
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category (DIN 40 050)
EN 50 081-2, EN 61 000-6-2
0°C … +70°C
-20°C … +70°C
-20°C … +85°C
-20°C … +85°C
housing for DIN-rail mounting
80 mm, 90 mm, 43 mm
housing IP65
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 83
Price Lists
EMC directions
AS-i Safety
Displays
AS-i Analog Module:
4 analog Inputs (M12)
AS-i Master/Gateways/
Links/Scanner
Programming:
M12 connector:
(Bit-setting of AS-i parameters)
Bit P0 (BWU1359, BWU2049):
1: Bridge between Pin 3 and 4 active
0: Bridge between Pin 3 and 4 not active
Bit P0 (BWU1360, BWU1742):
Not used
Bit P1 and P2:
1
24 V extern
2
Sig. +
3
0V
4
Sig. -
5
Shield
P1
P2
1
2
3
4
0
0
on
off
off
off
0
1
on
on
off
off
1
0
on
on
on
off
1
1
on
on
on
on
Bit P3:
1: Peripheral fault (e. g. broken wire to the sensor) is indicated
0: Peripheral fault (e. g. broken wire to the sensor) is not indicated
Accessories:
• AS-i substructure module to connect 2 AS-i flat cables (article no. BW1180, see page 183)
• AS-i substructure module to connect 1 AS-i flat cable, 1 flat cable for additional supply (article no. BW1181, see page 183)
• AS-i substructure module to connect 2 AS-i round cable (article no. BW1182, see page 183)
• AS-i substructure module to connect 1 AS-i round cable, 1 round cable for additional supply (article no. BW1183, see page 183)
• AS-i substructure module to connect 2 AS-i flat cables with addressing socket (article no. BW1438, see page 183)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Analog input is
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 84
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module:
4 analog Outputs (M12)
AS-i-Master/Gateways/
Links/Scanner
4 analog Outputs on M12 socket
Galvanical isolation to AS-i
0 … 20 mA
0 … 10 V
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
Article no. BWU1361 for 0 … 20 mA
Article no. BWU1362 for 0 … 10 V
Article no. BWU1722 for 0 … 20 mA, 24 V extern on M12
Article no. BWU1736 for 0 … 10 V, advanced temperature range: -20°C … +70°C
24 V supply is distributed additionally on M12 connectors for supply of small actutators (Imax < 1,1 A).
The actuators and AS-i are galvanical seperated.
The conversion of the measured value and the data transmission
via AS-i occurs asynchronically according to AS-i Profile 7.3. The
resolution of the analog data is 16 bit.
With infrared interface for slave addressing.
The analog module has 4 analog outputs.
The connection of the actuators is made by M12 connectors.
The current supply of the analog part (BWU1361, BWU1362) can
made out of AS-i or an external voltage supply (according to
PELV).
The current supply switches automatically to the supply out of external voltage supply, as soon as an external voltage is connected (BWU1361, BWU1362, BWU1736). At BWU1722 the external
-
BWU1736
4 outputs 0 … 10 V
24 V extern 1,1 A
-
16 bit/1 μA
Resolution
Range of value
BWU1362
16 bit/1 mV
0 … 20000 dec.
0 … 10000 dec.
AS-i Profile
7.3
ID Code
3hex
ID2 Code
6hex
IO Code
7hex
Displays
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
LED green (AUX)
voltage supply 24 V for the analog part
LED yellow (Out 1)
state of channel 1
LED yellow (Out 2)
state of channel 2
LED yellow (Out 3)
state of channel 3
LED yellow (Out 4)
Operating current
Operating voltage
state of channel 4
< 200 mA
< 100 mA
≥ 500 V
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category (DIN 40 050)
< 200 mA
AS-i (30 V DC)
Other Fieldbuses/
Master Simulators
Voltage supply, actuators
BWU1722
4 outputs 0 … 20 mA
AS-i Safety
BWU1361
Outputs
EN 50 081-2, EN 61 000-6-2
0°C … +70°C
-20°C … +70°C
-20°C … +85°C
-20°C … +85°C
housing for DIN-rail mounting
80 mm, 90 mm, 43 mm
housing IP65
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 85
Price Lists
Article no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
High protection category IP65
AS-i Analog Module:
4 analog Outputs (M12)
M12 connector:
(Bit-setting of AS-i parameters)
Bit P0:
1: Profile 7.3 is monitored
0: Profile 7.3 is not monitored
Bit P1, P3:
not used
Bit P2:
1: Peripheral fault (e. g. broken wire to the sensor) is indicated
0: Peripheral fault (e. g. broken wire to the sensor) is not indicated
BWU1361,
BWU1362,
BWU1736:
BWU1722:
1
Sig.+
1
Sig.+
2
n.c.
2
24 V ext.
3
Sig. -
3
Sig. -/0 V
4
n.c.
4
n.c.
5
Shield
5
Shield
Accessories:
• AS-i substructure module to connect 2 AS-i flat cables (article no. BW1180, see page 183)
• AS-i substructure module to connect 1 AS-i flat cable, 1 flat cable for additional supply (article no. BW1181, see page 183)
• AS-i substructure module to connect 2 AS-i round cable (article no. BW1182, see page 183)
• AS-i substructure module to connect 1 AS-i round cable, 1 round cable for additional supply (article no. BW1183, see page 183)
• AS-i substructure module to connect 2 AS-i flat cables with addressing socket (article no. BW1438, see page 183)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Programming:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 86
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module: 4 Pt100 Inputs (M12)
AS-i-Master/Gateways/
Links/Scanner
4 Pt100 Inputs on M12 socket
Galvanical isolation to AS-i
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
BWU2532
Inputs
4 Pt100 inputs
Voltage supply, sensors
via AS-i/extern
Internal resistance
Resolution
Measuring value
AS-i Profile
50 Ω
16 bit/0,1 °C
-200°C … +850°C
7.3
Programming:
(Bit-setting of AS-i parameters)
Bit P0:
1: 50 Hz filter in A/D Converter active
0: 60 Hz filter in A/D Converter active
Bit P1 and P2:
A peripheral fault can be released through channel:
ID Code
3hex
P1
P2
1
2
3
4
ID2 Code
Ehex
0
0
yes
no
no
no
IO Code
7hex
0
1
yes yes
no
no
1
0
yes yes yes
no
Displays
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
Bit P3
LED yellow (I1)
state of channel 1
BW1363
BWU2532
LED yellow (I2)
state of channel 2
1:2-wire mode
1:2-wire mode
LED yellow (I3)
state of channel 3
0:4-wire mode
0:3-wire mode
LED yellow (I4)
state of channel 4
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L / W / H in mm)
Protection category (DIN 40 050)
M12 connector:
BWU1363
BWU2532
≥ 500 V
1
CH+
1
EN 50 081-2
EN 61 000-6-2
2
CHS+
2
CHS–
3
CH-
3
CH– 0
0°C … +70°C
4
CHS-
4
*
-20°C … +85°C
5
Shield
5
Shield
housing for DIN-rail mounting
Other Fieldbuses/
Master Simulators
BWU1363
CH+
*) Pin 4 internally connected with Pin 3
80 / 90 / 43
housing IP65
Accessories:
• AS-i substructure module to connect 2 AS-i flat cables (article no. BW1180, see page 183)
• AS-i substructure module to connect 1 AS-i flat cable, 1 flat cable for additional supply (article no. BW1181, see page 183)
• AS-i substructure module to connect 2 AS-i round cable (article no. BW1182, see page 183)
• AS-i substructure module to connect 1 AS-i round cable, 1 round cable for additional supply (article no. BW1183, see page 183)
• AS-i substructure module to connect 2 AS-i flat cables with addressing socket (article no. BW1438, see page 183)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 87
AS-i Safety
Article no.
The resolution of the analog data is 16 bit. The analog modules
contains 50 Hz and 60 Hz filters. These filters can be optionally
activated with the help of the AS-i parameters.
With infrared interface for slave addressing.
Price Lists
The analog module has 4 Pt100 inputs.
The connection of the sensors is made by M12 connectors. The
analog sensors and AS-i are galvanical separated.
The conversion of the measured value and the data transmission
via AS-i occurs asynchronically according to AS-i Profile 7.3.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BWU2532 for 3 wire sensors
Article no. BWU1363 for 4 wire sensors
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 88
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
OEM Modules / AS-i Special Slaves
AS-i 2I/2O-AB Module
BW2033
2 analog inputs, 4 ... 20 mA
BW2035
2 analog inputs, 0 ... 10 V
BW2483
2 analog inputs, 0 ... 10 V, without wiring pins and screw
terminals
BW1421
BW1490
AS-i 4I/3O-AB Module
P.
93
93
with Fault LED output
BW1443
with screw terminals
BW1957
without galvanical separation, screw terminal only on AS-i
pins
BW1444
with wiring pins
BW1386
with wiring pins
BW1387
with screw terminals
BW1408
without wiring pins, without screw terminals
BW2229
with plug-in connector
BW1218
with wiring pins
BW1219
with screw terminals
BW1407
without wiring pins, without screw terminals
96
97
Price Lists
AS-i 4I/4O Module
Characteristic
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-OEM Module
Art. No.
Other Fieldbuses/
Master Simulators
Module
AS-i Safety
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview OEM Modules / AS-i Special Slaves
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 89
OEM Modules / AS-i Special Slaves
AS-i Master/Gateways/
Links/Scanner
Housing
Module
Art. No.
Characteristic
AS-i 4I/4O OEM Module
BW1628
with screw terminals
BW2054
with wiring pins
BW1388
galvanical separated, with wiring pins
BW1389
galvanical separated, with screw terminals
BW1910
galvanical separated,
without wiring pins, without screw terminals
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i 4I/4O Module
AS-i 4I/4O Module with LEDs
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i 6O-AB Module
AS-i 8I Module
AS-i 8I/8O Module
AS-i 16I/16O Module
AS-i OEM Slave with serial
interface
BW1468
LED display of the I/Os
BW1469
LED display of the I/Os, with wiring pins
BW1470
LED display of the I/Os, with screw terminals
BW1789
LED display of the I/Os, with screw terminals, lacquered
BW1627
with screw terminals
BW1679
with screw terminals, turned 180 degrees
BW1351
with wiring pins
BW1352
with screw terminals
BW1898
AS-i 8I/8O OEM Module, 2 4I/4O Single Slaves
BW1899
AS-i 3.0 8I/8O OEM Module, 2 4I/4O-AB Slaves
BW1900
AS-i 16I/16O OEM Module, 4 4I/4O Single Slaves
BW1901
AS-i 3.0 16I/16O OEM Module, 4 4I/4O-AB Slaves
developing platform for client specific electronics, specific
serial protocols
P.
98
99
100
101
102
103
103
105
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 90
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Module
Art. No.
Characteristic
AS-i OEM Power Supply Module
BW1485
OEM power supply out of AS-i
P.
106
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
AS-i-Master/Gateways/
Links/Scanner
OEM Modules / AS-i Special Slaves
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 91
AS-i Master/Gateways/
Links/Scanner
OEM Modules/AS-i Special Slaves
Special AS-i
Slaves Solutions
to
integrate in specific
electronics,
for building automation,
Bihl+Wiedemann does not offer standard AS-i I/O
modules to connect standard sensors or actuators to
the AS-i. The focus is more to use AS-i slaves to solve
very special problems in different fields with AS-i. Further special solutions on request.
coupling of 2 AS-i networks,
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
to connect serial devices
to the AS-i
AS-i 4I/4O Module
The AS-i 4I/4O Module, which meets the requirements of the AS-i
according to specification 2.1 is the board based solution for an
AS-i Slave. The module can be used perfectly to integrate into client specific hardware, e. g. push button panels, signal lamps,
actuating drives, etc.
AS-i Slaves for building automation
These AS-i Slaves are board bases solutions to fit in installation
housings. They are perfect to be used for building automation like
lighting systems, venetian blind applicatons, etc.
Coupling of 2 AS-i systems
The AS-i/AS-i Coupler provides the easiest solution to exchange
data between two PLCs via AS-i. In big applications with more
than one AS-i network there is often a need to exchange data
between two AS-i networks e. g. to report status information.
With the use of the AS-i/AS-i coupler to solve these problems the
installations costs as well as the components costs can be
reduced.
Cylindrical AS-i slaves
The cyclindrical AS-i Slaves are AS-i I/O modules inside stainless
steel sleeves. They can be mounted via reduction adapters in PG
or metrical fittings. In that way devices with high protection can
easily be interfaced to AS-i.
AS-i 4I Module for building automation
AS-i/AS-i Coupler
Cylindrical AS-i Actuator 1I/3O
AS-i Slave with serial interface
in protection class IP20
For special applications a new firmware to connect a special
device with serial interface can be implemented on the AS-i
slave. In that way the serial device can be optimaly adjusted to
the AS-i.
Price Lists
AS-i Safety
Connection of serial devices to the AS-i
The AS-i Slaves with serial interface offer the posibility to connect
complex devices, HMI terminals, serial printers, barcode scanners etc., to the AS-i.
4I/4O Module to integrate in client
specific electronics
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 92
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i OEM Modules: 2 analog Inputs
AS-i-Master/Gateways/
Links/Scanner
2 analog Inputs
4 ... 20 mA (BW2033) or 0 ... 10 V (BW2035, BW2483)
in one module
Profile 7.3 “Plug and Play“
As simple as digital AS-i I/O
AS-i Specification 2.1
Single Slave (up to 31 slaves)
Article no. BW2033 for 4 ... 20 mA
Article no. BW2035 for 0 ... 10 V
Article no. BW2483 for 0 ... 10 V
Connection
Installation
Analog inputs
AS-i specification
Voltage supply sensors
Internal resistance
Max. current per input
Max. supply current per input
Max. voltage per input
Resolution
Range of value
Measuring value
Transformation speed
AS-i Profile
ID Code
ID2 Code
IO Code
BW2033
BW2035
BW2483
wiring pins
–
circuit board installation
2
4 … 20 mA
0 ... 10 V
AS-i 2.1 single slave
via AS-i
82 Ω
100 kΩ
40 mA
–
40 mA
–
–
25 V
regular: 14-bit; fast: 11-bit
4000 … 20000 dec.
0 … 10000 dec.
0 ... 27648 dec.
0 ... 27648 dec.
4 ... 20 mA
0 ... 10 V
regular: 33 ms/14-bit; fast: 4,2 ms/11-bit
7.3
3hex
D
7hex
Operating current
Operating voltage
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Dimensions (L / W / H in mm)
< 120 mA
AS-i (30 V DC)
≥ 500 V
EN 61 000-6-2, EN 61 000-6-4
0°C … +70°C
-25°C … +85°C
73 / 37,6 / 10
Programming:
(Bit-setting of AS-i parameters)
Bit P0
1: peripheral fault is indicated
0: peripheral fault is not indicated
Bit P1 (BW2033)
1: 4000 … 20000 dec.
0: 0 ... 27648 dec. (Siemens format)
Bit P1 (BW2035)
1: 0 … 10000 dec.
0: 0 ... 27648 dec. (Siemens format)
Bit P1 (BW2483)
1: 0 … 10000 dec.
0: 0 ... 27648 dec. (Siemens format)
Bit P2
1: regular
0: fast
Other Fieldbuses/
Master Simulators
Article no.
The 4 ... 20 mA (BW2033) or 0 ... 10 V (BW2035, BW2483) signal shall not have a connection to earth. The resolution of the analog data is either 11 or 14 bit. The module offers 2 additional
holes for assembly angles.
Bit P3
1: channel 2 on
0: channel 2 off
AS-i Safety
The AS-i OEM Module with 2 analog inputs, meets the requirements of the AS-i Specification 2.1. The module is a board based
solution for an AS-i slave and it is completely powered by AS-i.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
2 additional holes for assembly angles
Connections:
Ch.1
37,6
Sig 2+
Sig 224V
0V
Sig 1+
Sig 1nc
ASIASI+
Ch.2
1
6
2,54
73
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 93
Price Lists
d 3,2
3,5
0V
+24V_12
E1
A1
0V
E2
A2
0V
E3
9
A3
08
7
E4
6
NC
5
0V
4
+24V_34
3
+24V_in
2
ASI1SI+
ASI
+
r2
18
9
8
7
6
5
4
3
2
1
66
7
AS-i 2I/2O AB Module
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 2I/2O-AB Module
AS-i Specification 2.1
AB Slave (up to 62 slaves)
Additional 2 holes
for angles
BW1421 / BW1490
Other Fieldbuses/
Master Simulators
with wiring pins
Article no. BW1421
Article no. BW1443 with screw terminals
Article no. BW1957 without galvanical separation, screw terminal only on AS-i pins
Article no. BW1444 with wiring pins
Article no. BW1490 with Fault LED output
lights, with the power being drawn from the AS-i system.
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
The AS-i 2I/2O-AB Module offers additionally 2 holes for assembly angles.
Advanced addressing (AB-technology, up to 62 slaves) is possible.
The AS-i 2I/2O-AB Module, which meets the requirements of the
new AS-i Specification 2.1 is the board based solution for an AS-i
slave. The board is completely powered by AS-i. The inputs and
outputs are short circuit and overload protected.
If bus communication is interrupted (master failure), the outputs
are switched to their currentless switching state by the watchdog.
Using the inputs, you can interrogate up to 2 mechanical switching elements. Using the outputs, you can drive up to 2 indicator
Article no.
BW1421
BW1443
BW1957
BW1444
BW1490
Connection
-
screw terminal
screw terminal
only on AS-i pins
wiring pins
-
Connection
Quiescent current
(Input = 0, Output = 0)
≤ 20 mA
≤ 0,8 mA (low)
≥ 5 mA (high)
U
20 … 30 V DC
Outputs
Loading capacity
Length of connector cables
2, electronic
80 mA per output (sum of all outputs < 80 mA) 24 V DC
I/O: max. 1,5 m
Operating voltage
via AS-i
Operating current
≤ 200 mA
Operating temperature
EN 61 000-6-2 , EN 61 000-6-4
-40°C … +70°C
Protection category
(EN 60 529)
IP00 (soldering pins)
IP20 (build in)
Allowable shock and
vibration stress
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
29,7 /36,5 /10
27,7 /36,5 /10
IO Code B
ID Code A
ID2 Code E
Price Lists
Dimensions (L /W /H in mm)
Parameter bit
Bit Function
P0 not used
P1 not used
P2 not used
P3 not used
Programming:
Address preset 0
changeable via bus
master or programming
devices
-25°C … +70°C
Storage temperature
Programming
(Bit-setting)
Data bit
(Input via AS-i)
Bit Function
D0 Output A1
D1 Output A2
D2 Input E1
D3 Input E2
circuit board installation
Switching threshold
of inputs
EMC directions
AS-i Safety
with screw terminals
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 94
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 2I/2O AB Module
AS-i-Master/Gateways/
Links/Scanner
Art. no.: 1421/1443/1957/1444
0V
E2
A2
0V
+
nc
nc
ASI-
ASI+
11 10
9
8
7
6
5
4
3
2
1
E1
A1
37,6
29,7
77
d 3,2
2,6
1
6
3,5
3,5
0V
+24V_12
E1
A1
0V
E2
A2
0V
E3
A3
0
E4
NC
0V
+24V_34
+24V_in
ASIASI
SI+
+
r2
18
32
66
5,2
19,9
2,54
2,54
36,5
73
ASI
IO-Block 1+2
A2
0V
+
+ (Uout)
- (LED)
ASI-
ASI+
11 10 9
E2
0V
A1
E1
37,6
27,7
8
7
6
5
4 3
2
1
57
d 3,2
2,6
1
6
1,5
3,5
0V
+24V_12
E1
A1
0V
E2
A2
0V
E3
A3
0
E4
NC
0V
+24V_34
+24V_in
ASIASI
SI+
+
r2
18
32
66
5,2
19,9
2,54
2,54
ASI
IO-Block 1+2
36,5
73
Uout
Iled
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
R=
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
1490
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 95
AS-i 4I/3O-AB Module
AS-i specification 2.1
AB slave (up to 62 slaves)
Additional 2 holes for
assembly angles
BW1386
BW1408
BW2229
Article no. BW1386 with wiring pins
Article no. BW1387 with screw terminals
Article no. BW1408 without screw terminals, without wiring pins
Artikel no. BW2229 with plug-in connector
The AS-i 4I/3O AB Module, which meets the requirements of the
AS-i according to specification 2.1 is the board based solution for
an AS-i Slave. The board is completely powered by AS-i. The inputs and outputs are short circuit and overload protected.
Using the inputs, you can interrogate up to 4 mechanical switching elements.
If bus communication is interrupted (master failure), the outputs
are switched to their currentless switching state by the watchdog.
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
Using the outputs, you can drive up to 3 indicator lights, with the
power being drawn from the AS-i system.
Programming
Article no.
BW1386
BW1387
BW1408
BW2229
Connection
wiring pins
screw terminals
–
plug-in connector
Connection
(Bit-setting)
circuit board installation
Data bit (input via AS-i)
≤ 20 mA
Quiescent current
(Input = 0, Output = 0)
Switching threshold of inputs
≤ 0,8 mA (low)
≥ 5 mA (high)
U
20 … 30 V DC
Outputs
Bit
D0
D1
D2
D3
Function
input I1 / output O1
input I2 / output O2
input I3 / output O3
input I4 / output O4
3, electronic
Loading capacity
Parameter bit
80 mA per output (Sum of all outputs < 80mA) 24 V DC
Length of connector cables
Bit
P0
P1
P2
P3
I/O: max. 1,5 m
Operating voltage
via AS-i
≤ 200 mA
Operating current
EMC directions
EN 50 081-2, EN 50 082-2
Ambient operating temperture
Programming:
-40°C … +70°C
Protection category EN 60 529
IP00 (soldering pins)
IP20 (build in)
Allowable shock and vibration
stress
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Dimensions (L / W / H in mm)
Function
not used
not used
not used
not used
-25°C … +70°C
Storage temperature
73 / 37,5 / 7
73 / 37,5 / 10
73 / 37,5 / 7
Address preset 0,
changeable via bus master
or programming devices
IO-Code 7
ID-Code A
ID2-Code E
73 / 55,2 / 12
nc
+
I1
O1
0
I2
O2
0
I3
O3
0
I4
nc
0
+
nc
ASIASI+
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
37,6
17
AS-i Safety
BW1387
18
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 4I/3O-AB Module
7
d 3,2
1
1
6
Price Lists
3,5
0V
+24V_12
I1
O1
0V
I2
O2
0V
I3
O3
0
I4
NC
0V
+24V_34
+24V_in
ASIASI
SI+
+
r2
18
66
19,9
2,54
73
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 96
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 4I/4O Module
AS-i-Master/Gateways/
Links/Scanner
AS-i-4I/4O Module
AS-i Specification 2.1
Single Slave (up to 31 slaves)
Additional 2 holes for
assembly angles
BW1219
BW1407
Article no. BW1218 with wiring pins
Article no. BW1219 with screw terminals
Article no. BW1407 without screw terminals, without wiring pins
If bus communication is interrupted (master failure), the outputs
are switched to their currentless switching state by the watchdog.
Using the inputs, you can interrogate up to 4 mechanical switch-
Article no.
BW1218
Connection
wiring pins
Connection
ing elements. Using the outputs, you can drive up to 4 indicator
lights, with the power being drawn from the AS-i system.
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
The AS-i 4I/4O Module offers additionally 2 holes for assembly
angles.
BW1219
BW1407
screw terminals
–
Programming
(Bit-setting)
circuit board installation
Data bit
(Input via AS-i)
Bit function
D0 input I1/output O1
D1 input I2/output O2
D2 input I3/output O3
D3 input I4/output O4
≤ 20 mA
Quiescent current
(Input = 0, Output = 0)
Switching threshold of inputs
≤ 0,8 mA (low)
≥ 5 mA (high)
U
20 … 30 V DC
Outputs
Other Fieldbuses/
Master Simulators
The AS-i 4I/4O Module, which meets the requirements of the AS-i
according to the specification 2.1 is the board based solution for
an AS-i slave. The board is completely powered by AS-i. The
inputs and outputs are short circuit and overload protected.
4, electronic
Loading capacity
100 mA per output (sum of all outputs < 180 mA)
24 V DC
Length of connector cables
Parameter bit
Bit function
P0 not used
P1 not used
P2 not used
P3 not used
I/O: max. 1,5 m
Operating voltage
via AS-i
Operating current
≤ 200 mA
EN 50 081-2, EN 50 082-2
Ambient operating temperature
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection category EN 60 529
IP00 (soldering pins)
IP20 (build in)
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Allowable shock and vibration stress
Dimensions (L / W / H in mm)
Programming:
Address preset 0
changeable via bus master or
programming devices
73 / 37,5 / 7
73 / 37,5 / 10
AS-i Safety
EMC directions
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW1218
IO code 7
ID code 0
ID2 code F
73 / 37,5 / 7
nc
+
E1
A1
0
E2
A2
0
E3
A3
0
E4
A4
0
+
nc
ASIASI+
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
37,6
d 3,2
1
1
6
19,9
2,54
73
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 97
Price Lists
7
3,5
0V
nc
+24V_12
+
E1
E1
A1
A1
0V
0
E2
E2
A2
A2
0V
0
E3
E3
A3
A3
00
E4
E4
A4
NC
0
0V
+
+24V_34
nc
+24V_in
ASIASIASI+
ASI
SI+
+
r2
18
66
AS-i 4I/4O OEM Module
AS-i Specification 2.1
Single Slave (up to 31 slaves)
2 additional holes for
assembly angles
Outputs galvanically isolated
Inputs supplied by AS-i
BW1628
AS-i Safety
If bus communication is interrupted (master failure), the outputs are
switched to their currentless switching state by the watchdog. A
short-circuit of the outputs is notified as peripheral fault.
Customer-specific special solutions can be offered on demand. The
circuit board dimensions and the plug connections can be modified
also.
The AS-i 4I/4O OEM Module offers additionally 2 holes for assembly angles.
The AS-i 4I/4O OEM Module which meets the requirements of the
AS-i Specification 2.1 is the board based solution for an AS-i slave.
The inputs are powered out of AS-i and the outputs out of separated
24 V. The outputs are gavanically isolated. Besides the in- and outputs are short-circuit-protected, overload-proof and pole-protected.
The state of the in- and outputs is indicated through 8 LEDs. Additionally the both AS-i LEDs (PWR green and FAULT red) display the
state of the AS-i slaves as by AS-i slaves usually and Uaux is indicated with a green LED.
Article no.
BW1628
BW2054
Connection
screw terminals
wiring pins
Connection
Programming
(Bit-setting)
circuit board installation
8 LEDs yellow
Data bit
(input via AS-i)
Bit function
D0 input I1/output O1
D1 input I2/output O2
D2 input I3/output O3
D3 input I4/output O4
states of in-/output channel 1 - 4
LED green (PWR)
AS-i voltage OK
LED red (FAULT)
communication error
LED green (Uaux)
separated 24 V OK
Quiescent current
(Input = 0, Output = 0)
< 20 mA
Switching threshold of inputs
Parameter bit
Bit function
P0 not used
P1 not used
P2 not used
P3 not used
< 0,8 mA (low), > 5 mA (high)
U
20 … 30 V DC (PELV)
Outputs
4, electronic
Loading capacity of inputs
sum of all inputs < 180mA, supplied out of AS-i
Loading capacity of outputs
150 mA per output (sum of all outputs < 500mA), supplied by
separated 24 VDC
Length of connector cables
I/O: max. 1,5 m
Operating voltage
Via AS-i
Operating current
< 20 mA
EMC directions
Programming:
Address preset 0
changeable via bus master or
programming devices
EN 50 081-2, EN 50 082-2
Ambient operating temperature
IO code 7
ID code 0
ID2 code E
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection category EN 60 529
IP00 (soldering pins)
IP20 (build in)
Dimensions (L / W / H in mm)
73 / 37,5 / 10
73 / 37,5 / 7
0V_in
+24V
E1
A1
0V
E2
A2
0V
E3
A3
0V
E4
A4
0V
+24V
+24V_in
ASIASI+
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
37,6
7
d 3,2
1
Hint:
The module can not be used
with the OEM carrier board
BW1484.
0 V is generated out of 0V_in,
+24 V is generated out of
ASI+.
Between +24 V and 0 V no
consumers may be connected.
6
3,5
0V
0V_in
+24V_12
+24V
E1
E1
A1
A1
0V
0V
E2
E2
A2
A2
0V
0V
E3
E3
A3
A3
00V
E4
E4
A4
NC
0V
0V
+24V
+24V_34
+24V_in
+24V_in
ASIASIASI+
ASI
SI+
+
r2
18
66
Price Lists
BW2054
Article no. BW1628 with screw terminals
Article no. BW2054 with wiring pins
1
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 4I/4O OEM Module
19,9
2,54
73
Pwr
IN
IO-Block 1+2
IO-Block 3+4
Pwr ASI
IN
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 98
Mannheim, 29.3.11We reserve the right to change any datawww.bihl-wiedemann.de
AS-i 4I/4O Module
Inputs/outputs galvanically separated
BW1388
BW1389
Article no. BW1388 with wiring pins
Article no. BW1389 with screw terminals
Article no. BW1910 without wiring pins, without screw terminals
The AS-i 4I/4O Module, which meets the requirements of the AS-i
according to specification 2.1 is the board based solution for an
AS-i slave. The inputs and outputs are powered out of separated
24 V and are gavanical separated to the AS-i. Besides they are
short-circuit-protected, overload-proof and pole-protected.
If bus communication is interrupted (master failure), the outputs
are switched to their currentless switching state by the watchdog.
Using the inputs, you can interrogate up to 4 mechanical switching elements.
Article no.
BW1388
Connection
wiring pins
Connection
Using the outputs, you can drive up to 4 indicator lights, with the
power for the inputs and the outputs being drawn from separated
24 V.
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
The AS-i 4I/4O Module offers additionally 2 holes for assembly
angles.
BW1389
BW1910
screw terminals
–
circuit board installation
Data bit
(Input via AS-i)
Bit function
D0 input I1/output O1
D1 input I2/output O2
D2 input I3/output O3
D3 input I4/output O4
≤ 20 mA
Quiescent current
(Input = 0, output = 0)
≤ 0,8 mA (low)
≥ 5 mA (high)
Switching threshold of inputs
U
20 … 30 V DC (PELV)
Outputs
4, electronic
100 mA per output (sum of all outputs < 200 mA), 24 V DC
Length of connector cables
I/O: max. 1,5 m
Operating voltage
via AS-i
Operating current
≤ 20 mA
EMC directions
EN 50 081-2, EN 50 082-2
Ambient operating temperature
Parameter bit
Bit function
P0 not used
P1 not used
P2 not used
P3 not used
-25°C … +70°C
Storage temperature
Programming:
Address preset 0
changeable via bus master
or programming devices
-40°C … +70°C
Protection category EN 60 529
IP00 (soldering pins)
IP20 (build in)
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Allowable shock and vibration stress
Dimensions (L / W / H in mm)
73 / 37,5 / 7
73 / 37,5 / 10
73 / 37,5 / 7
IO code 7
ID code 0
ID2 code F
AS-i Safety
Loading capacity
Programming
(Bit-setting)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Additional 2 holes for
assembly angles
Other Fieldbuses/
Master Simulators
AS-i Specification 2.1
Single Slave (up to 31 slaves)
AS-i-Master/Gateways/
Links/Scanner
AS-i 4I/4O Module
37,6
Pwr
IN
IO-Block 1+2
IO-Block 3+4
Pwr ASI
IN
d 3,2
6
19,9
2,54
73
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 99
Price Lists
7
3,5
0V
18
0V
+24V_12
+24V_12
E1
E1
A1
A1
0V
0V
E2
E2
A2
A2
0V
0V
E3
E3
A3
A3
00V
E4
E4
A4
NC
0V
0V
+24V_34
+24V_34
+24V_in
+24V_in
ASIASIASI+
ASI
SI+
+
1
r2
66
AS-i 4I/4O Module with LEDs
LED display of the I/Os
AS-i Specification 2.1
Single Slave (up to 31 slaves)
Additional 2 holes for
assembly angles
Article no. BW1468
Article no. BW1469 with wiring pins
Article no. BW1470 with screw terminals
Article no. BW1789 with screw terminals, lacquered
The AS-i 4I/4O Module offers additionally 2 holes for assembly
angles.
Article no.
BW1468
Connection
–
BW1469
BW1470 BW1789
wiring pins
screw terminals
Programming
(Bit-setting)
circuit board installation
Data bit
(Input via AS-i)
Bit function
D0 input I1/output O1
D1 input I2/output O2
D2 input I3/output O3
D3 input I4/output O4
≤ 20 mA
Quiescent current
(Input = 0, Output = 0)
Switching threshold of inputs
≤ 0,8 mA (low)
≥ 5 mA (high)
U
20 … 30 V DC
Outputs
4
100 mA per output (sum of all outputs < 180 mA) 24 V DC
Length of connector cables
Parameter bit
Bit function
P0 not used
P1 not used
P2 not used
P3 not used
I/O: max. 1,5 m
Operating voltage
via AS-i
Operating current
≤ 200 mA
EMC directions
EN 50 081-2, EN 50 082-2
Ambient operating temperature
Storage temperature
-25°C … +70°C
Programming:
Address preset 0
changeable via bus master
or programming devices
-40°C … +70°C
Protection category EN 60 529
IP00 (soldering pins)
IP20 (build in)
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
IO code 7
ID code 0
ID2 code F
E1
A1
0
E2
A2
0
E3
A3
0
E4
A4
0
+
nc
ASIASI+
15
14
13
12
11
10
9
8
7
6
5
4
3
2
73 / 37,5 / 10
+
73 / 37,5 / 7
16
Dimensions (L / W / H in mm)
nc
Allowable shock and
vibration stress
37,6
7,6
1
Loading capacity
17
Other Fieldbuses/
Master Simulators
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
If bus communication is interrupted (master failure), the outputs
are switched to their currentless switching state by the watchdog.
Connection
AS-i Safety
Using the inputs, you can interrogate up to 4 mechanical switching elements. Using the outputs, you can drive up to 4 indicator
lights, with the power being drawn from the AS-i system.
The AS-i 4I/4O Module, which meets the requirements of the AS-i
according to specification 2.1 is the board based solution for an
AS-i slave. The board is completely powered by AS-i. The inputs
and outputs are short circuit and overload protected. The status
of the in- and outputs is displayed by 8 LEDs. Additionally the
both AS-i LEDs (AS-i Power green and AS-i Error red) show the
status of the AS-i slave as by AS-i slaves usually.
18
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 4I/4O Module with LEDs
d 3,2
1
6
Price Lists
3,5
0V
nc
+24V_12
+
E1
E1
A1
A1
0V
0
E2
E2
A2
A2
0V
0
E3
E3
A3
A3
00
E4
E4
A4
NC
0
0V
+
+24V_34
nc
+24V_in
ASIASIASI+
ASI
SI+
+
r2
18
66
7
19,9
2,54
73
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 100
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 6O-AB Module
Additional 2 holes for
assembly angles
Article no. BW1627 with screw terminals
Article no. BW1679 with screw terminals, turned 180 degrees
The AS-i 6O-AB Module, which meets the requirements of the
AS-i according to specification 2.1 is the board based solution for
an AS-i slave. The board is completely powered by AS-i. The outputs are short circuit and overload protected.
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
The board consists out of 2 AS-i A/B Slaves.
AS-i addressing/startup: The second AS-i slave is disconnected
until the first AS-i slave is in data exchange. Also with the help of
a dip-switch the 2. AS-i slave could be separated from the AS-i
line.
The module offers additionally 2 holes for assembly angles.
Using the outputs, you can drive up to 6 indicator lights, with the
power being drawn from the AS-i system.
Article no.
BW1627
BW1679
Connection
screw terminals
screw terminals,
turned 180 degrees
Connection
circuit board installation
≤ 20 mA
Quiescent current (Output = 0)
Outputs
6, electronic
Loading capacity
100 mA per output (sum of all outputs < 180 mA)
24 V DC
U
20 … 30 V DC
Supply current
max. 200 ma
Length of connector cables
max. 1,5 m
Operating voltage
via AS-i
Operating current
≤ 200 mA
EMC directions
EN 50 081-2, EN 50 082-2
Ambient operating temperature
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection category EN 60 529
IP00 (soldering pins)
IP20 (build in)
Allowable shock and vibration stress
Dimensions (L, W, H)
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
73 mm, 37,5 mm, 10 mm
Programming
(Bit-setting)
Data bit
(Input via AS-i)
Bit functions
D0 output O1, slave 1
D1 output O2, slave 1
D2 output O3, slave 1
D3 D4 output O4, slave 2
D5 output O5, slave 2
D6 output O6, slave 2
D7 Programming:
Address preset 0 + 1
changeable only via AS-i master in
configuration mode.
IO code: 8
ID code: A
ID2 code: 0
1: 2. AS-i slave connected
1: 2. AS-i slave disconnected
37,6
AS-i Safety
If bus communication is interrupted (master failure), the outputs
are switched to their currentless switching state by the watchdog.
Other Fieldbuses/
Master Simulators
AS-i Specification 2.1
AB-Slave (up to 62 slaves)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i 6O-AB Module
r2
66
6
19,9
2,54
73
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 101
Price Lists
d 3,2
nc
nc
A1
A2
0
A3
A4
0
nc
A5
0
nc
A6
0
nc
nc
ASIASI
SI++
7
3,5
AS-i 8I Module
AS-i Master/Gateways/
Links/Scanner
AS-i 8I Module
AS-i Specification 2.1
AB Slave (up to 62 slaves)
Additional 2 holes
for angles
BW1351
BW1352
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1351 with wiring pins
Article no. BW1352 with screw terminals
The AS-i 8I Module, which meets the requirements of the AS-i
according to specification 2.1 is the board based solution for 2
AS-i slave. The board is completely powered by AS-i. The power
supply is short circuit and overload protected.
The board exists of 2 AS-i A/B-Slaves.
With the inputs 8 mechnical switches can be interrogated.
The AS-i 8I Module offers additionally 2 holes for assembly
angles.
AS-i addressing: The second AS-i slave is disconnected until the
first AS-i slave is in data exchange. Also with the help of a
dip-switch the 2. AS-i slave could be separated from the AS-i line.
Article no.
BW1351
BW1352
Connection
wiring pins
screw terminals
Connection
Programming
(Bit-setting)
circuit board installation
Quiescent current (Input = 0)
≤ 20 mA
Switching threshold of inputs
≤ 0,8 mA (low)
≥ 5 mA (high)
U
20 … 30 V DC
Supply current
max. 200 mA
Length of connector cables
Other Fieldbuses/
Master Simulators
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
Data bit
(Input via AS-i)
Bit function
D0 input I1, slave 1
D1 input I2, slave 1
D2 input I3, slave 1
D3 input I4, slave 1
D4 input I5, slave 2
D5 input I6, slave 2
D6 input I7, slave 2
D7 input I8, slave 2
max. 1,5 m
Operating voltage
via AS-i
Operating current
≤ 200 mA
EMC directions
EN 50 081-2, EN 50 082-2
Ambient operating temperature
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection category EN 60 529
Allowable shock and vibration stress
Dimensions (L / W / H in mm)
Programming:
Address preset 0 + 0
changeable only via AS-i Master in
configuration mode.
IP00 (soldering pins)
IP20 (build in)
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
73 /37,5 /7
IO code 0
ID code A
ID2 code 2
7 /37,5 /10
nc
+
E1
E2
0
E3
E4
+
E5
E6
0
E7
E8
0
+
nc
ASIASI+
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
37,6
18
AS-i Safety
1: 2. AS-i slave connected
1: 2. AS-i slave disconnected
7
d 3,2
Price Lists
1
1
6
3,5
0V
+24V_12
E1
A1
0V
E2
A2
0V
E3
A3
0
E4
NC
0V
+24V_34
+24V_in
ASIASI
SI+
+
r2
18
66
19,9
2,54
73
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 102
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 8I/8O / 16I/16O Module
AS-i-Master/Gateways/
Links/Scanner
AS-i 8I/8O OEM Module
2 4I/4O Single Slaves
AS-i 3.0 8I/8O OEM Module
2 4I/4O-AB Slaves
AS-i 16I/16O OEM Module
4 4I/4O Single Slaves
AS-i 3.0 16I/16O OEM Module
Article no. BW1898 AS-i 8I/8O OEM Module, 2 4I/4O Single Slaves
Article no. BW1899 AS-i 3.0 8I/8O OEM Module, 2 4I/4O-AB Slaves
Article no. BW1900 AS-i 16I/16O OEM Module, 4 4I/4O Single Slaves
Article no. BW1901 AS-i 3.0 16I/16O OEM Module, 4 4I/4O-AB Slaves
The addressing of 2 resp. 4 AS-i slaves is very easy with the help
of 2 resp. 4 addressing sockets.
The extended addressing (AB-technique: up to 62 slaves, Single
Slaves: up to 31 slaves) is possible.
Customer-specific special orders are possible on short notice.
The circuit board dimensions and the plug connections can be
changed as well.
BW1899
BW1900
BW1901
Programming
(Bit-setting)
AS-i Specification
Extended addressing
Addressing
AS-i 2.1
AS-i 3.0
AS-i 2.1
AS-i 3.0
≤ 31 slaves ≤ 62 slaves ≤ 31 slaves ≤ 62 slaves
2 slaves
2 slaves
4 slaves
4 slaves
Connection
wiring pins
Connection
circuit board installation
Quiescent current
(input = 0, output = 0)
≤ 40 mA
≤ 50 mA
≤ 0,3 mA (low)
≥ 2 mA (high)
Switching threshold of inputs
U
Outputs
Inputs
Loading capacity
Length of connector cables
20 .. 30 V DC
8
16
8
16
70 mA per output (sum of all outputs < 200 mA)
24 V DC, no inductive load, no short circuit
I/O: max. 1,5 m
Operating voltage
Operating current
EMC directions
via AS-i
≤ 400 mA
≤ 500 mA
EN 61000-6-2, EN 61000-6-4
Ambint operating temperature
-25°C .. +70°C
Storage temperature
-40°C .. +70°C
Protection category EN 60 529
IP00
Allowable shock and vibration
stress
≤ 15 g, T ≤ 11 ms
10 .. 55 Hz, 0,5 mm amplitude
Dimensions (L / W / H in mm)
104 / 41 / 16
93 / 51 / 16
Data bit
(Input via AS-i)
Bit function
D0 input I1/output O1
D1 input I2/output O2
D2 input I3/output O3
D3 input I4/output O4
Parameter bit BW1898, BW1900
Bit function
P0 not used
P1 not used
P2 not used
P3 not used
Parameter bit BW1899, BW1901
Bit function
P0 0 = off/1 = on (watchdog)
P1 0 = on/1 = off (data input filter 128 µs)
P2 0 = on/1 = off (synchronous data I/O mode)
P3 not used
Other Fieldbusses/
Master Simulators
BW1898
AS-i Safety
Article no.
Programming:
Address preset 0
changeable via bus master or programming
devices
AS-i Spec.
IO code
ID code
ID1 code
ID2 code
2.1
7
F
(F)
E
3.0
7
A
7 (fixed)
7
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 103
Preisl Lists
The AS-i Special Slave is realized by 2 resp. 4 AS-i slaves. The
board is completely powered by AS-i.
A watchdog function is integrated. It powers the outputs off, if bus
communication is interrupted (master failure).
The inputs/outputs can head for up to 8 resp. 16 LEDs. The energy is supplied by the AS-i system.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW1898, BW1899 BW1900, BW1901
4 4I/4O-AB Slaves
AS-i 8I/8O / 16I/16O Module
26 pin Data bit
Signal name
26 pin Data bit
Signal name
1
-
-
14
ASI1.E3
E4
2
-
-
15
ASI2.A1
A6
3
ASI+
ASI +
16
ASI1.E2
E3
4
ASI-
ASI-
17
ASI2.A0
A5
5
-
-
18
ASI1.E1
E2
6
ASI2.E3
E8
19
ASI1.A3
A4
7
-
-
20
ASI1.E0
E1
8
ASI2.E2
E7
21
ASI1.A2
A3
9
-
-
22
GND_EXT GND_EXT
10
ASI2.E1
E6
23
ASI1.A1
11
ASI2.A3
A8
24
+24V_EXT +24V_EXT
12
ASI2.E0
E5
25
ASI1.A0
A1
13
ASI2.A2
A7
26
-
-
A2
Connnections 16I/16O Module
Other Fieldbussee/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Connnections 8I/8O Module
41
36.5
d4
d4
40 pin Data bit
Signal name
40 pin Data bit
Signal name
1
ASI1.A0
A1
21
ASI3.A1
A10
2
ASI1.A1
A2
22
+24V
+24V
3
ASI1.A2
A3
23
ASI3.A0
A9
4
ASI4.E1
E14
24
ASI1.E2
E3
5
ASI1.A3
A4
25
ASI2.A3
A8
6
ASI4.E0
E13
26
ASI2.E0
E5
7
ASI2.A0
A5
27
ASI2.A2
A7
8
ASI3.E3
E12
28
ASI1.E3
E4
9
ASI4.A3
A16
29
ASI2.A1
A6
10
ASI3.E2
E11
30
ASI2.E1
E6
11
ASI4.A2
A15
31
-
-
12
ASI3.E1
E10
32
ASI1.E1
E2
13
ASI4.A1
A14
33
+24V
+24V
14
ASI3.E0
E9
34
ASI1.E0
E1
15
ASI4.A0
A13
35
ASI4.E3
E16
16
+24V
+24V
36
GND
GND
17
ASI3.A3
A12
37
+24V
+24V
18
ASI2.E3
E8
38
+24V
+24V
19
ASI3.A2
A11
39
ASI4.E2
E15
20
ASI2.E2
E7
40
GND
GND
51
46
45.5
d 3.3
d 3.3
d4
15
9.8
d4
89.25
93
70.5
73.17
51
31.5
22.37
Preis Lists
10.51
12
15.02
d 3.3
d 3.3
9.77
3.5
2.37
0
3.75
104
99.5
48.8
4.5
4.5
5.5
AS-i Safety
26
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 104
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i OEM Slave with serial Interface
AS-i-Master/Gateways/
Links/Scanner
AS-i OEM Slave with serial Interface
Developing platform for
client specific electronics,
specific serial protocols
Single slave
(A/B slave possible with appropriate protocol)
Customer-specific special orders are possible on short notice.
Technical data
Connection
screw terminals
Connection
circuit board installation
Customer interface
TTL, RS 232 or RS 485,
galvanical separated to AS-i
Baud rates
Up to 19200 bit/s
Length of connector cable
I/O: max. 1,5 m
Operating voltage AS-i part
Via AS-i
Operating voltage customer interface 20 … 30 V DC,
80 mA out of customer electronic,
5 V supply on request
Operating current AS-i part
≤ 100 mA
EMC directions
EN 61 000-6-2, EN 61 000-6-4
Ambient operating temperature
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection category (EN 60 529)
IP20 (build in)
Allowable shock and vibration stress ≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Data range
Analog input data image, channel 1
Parameter bit
Bit function
P0 not used
P1 not used
P2 not used
P3 not used
Programming:
Address preset 0
changeable via bus master or programming devices
IO code 7
ID code 3
ID2 code 8
73 mm, 37,5 mm, 10 mm
Pin Connection
Pin Connection
1
ASI+
10
RXD TTL
2
ASI-
11
TXD TTL
3
nc
12
TXD RS 232
4
nc
13
RXD RS 232
5
nc
14
GND supply input
6
nc
15
RS 485 positive
7
nc
16
RS 485 negative
8
nc
17
24 V supply input
9
nc
18
nc
Price Lists
Dimensions (L, W, H)
Programming
(Bit-setting)
Other Fieldbuses/
Master Simulators
can be operated easily in the AS-i master via the command interface from a PLC.
AS-i Safety
The AS-i OEM Slave with serial interface is a developing platform
with its help client specific electronics can be connected to AS-i.
With the help of the AS-i profile S-7.3 (other profiles on request)
a greater data volume can be transferred via AS-i easily. The data
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Additional 2 holes for assembly angles
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any dataMannheim, 29.3.11
page 105
AS-i OEM Power Supply Module
AS-i Master/Gateways/
Links/Scanner
AS-i OEM Power Supply Module
OEM Power Supply out of AS-i
Uaux out of AS-i
1,5 A max. (by approx. 24 V)
Help energy out of AS-i
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no.BW1485
With the help of the OEM Power Supply Module it is possible to
take out up to 1,5 A current (by approx. 24 V) out of AS-i. The
help energy can be used for supply of ventils or other consumers.
Every time if there is no additional help energy for supply available for example in moved parts, in robots or by far away locations
in a plant, it is possible to take out the help energy out of AS-i with
the help of the OEM Power Supply Module. With help of the OEM
Power Supply Module it is possible to cut of conducting additional
24 V help energy to bad accessible places.
Article no.
BW1485
Connection
via fastened line
20 … 30 V DC
Uaux
Loading capacity
1,5 A
EMC directions
Other Fieldbuses/
Master Simulators
The OEM Power Supply Module occupies no slave addresses.
But the module loads the AS-i circuit with the impedance of 7 AS-i
slaves (single slaves). Therefore the maximum account of slaves
is restricted. According AS-i specification it is allowed to operate
only up to 24 single or 48 AB-slaves in connection with a OEM
Power Supply Module at an AS-i rope.The OEM Power Supply
Module is short circuit protected. For protection against dust and
humidity the modul is varnished.
EN 50 081-2, EN 50 082-2
Operating temperature
-25°C … +70°C
Storage temperature
-25°C … +70°C
Protection category EN 60 529
IP00
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Allowable shock and vibration stress
Dimensions (L, W, H)
73 mm, 37,5 mm, 7 mm
37,6
d 3,2
1
6
19,9
2,54
73
Price Lists
AS-i Safety
7
3,5
0V
Uaux+24V_12
nc
E1
nc
A1
nc
0V
nc
E2
nc
A2
nc
0V
nc
E3
nc
A3
nc
0nc
E4
nc
NC
nc
0V
nc
+24V_34
nc
+24V_in
Uaux+
ASIASIASI
SI+
+
ASI+
r2
18
66
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 106
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Specialities
P.
AS-i 4I/3O Relay Module
BW1808
with addressing socket, AB Slave
AS-i 4I/4O Relay Module
BW1926
with addressing socket, Single Slave
AS-i 4I/4O Module
BW1907
with addressing socket, AB Slave
114
AS-i 8I Module
BW2077
with addressing socket, AB Slave
115
AS-i 8O Module
BW2078
with addressing socket, AB Slave
116
AS-i Analog Module
BW2313
2 inputs Pt100
+ 4 digital inputs/ outputs in IP67 (M12)
109
AS-i 3.0 Universal Module in IP65
BW1931
analog and digital inputs/outputs in one module
AS-i Counter Module
BWU2218
2-channel input
BWU2219
2 x 2-channel input
BWU2189
4 x 2-channel input
BW1723
1-channel input (analog)
119
BW1711
1-channel input (0 to 15)
120
AS-i Analog Module: 2 inputs for
Leuze ODSL 30 distance sensors
BW1908
0 ... 65 m
121
BW1664
0 ... 30 m
AS-i Code Block
BW1527
with 2 code switches
122
AS-i/AS-i Coupler
BW1187
connection of 2 AS-i networks via 2 internal 4I/4O slaves
123
BW1280
connection of 2 AS-i networks via 2 internal 4I/4O slaves, 124
protection category IP65
108
117
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Characteristic
Other Fieldbuses/
Master Simulators
Art. No.
AS-i Safety
Module
Price Lists
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Specialities
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 107
AS-i Relay Module in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
AS-i Relay Module in Stainless Steel
LED display of the I/Os
AS-i specification 2.1
Connection via cage clamp terminal blocks
Relay contacts as change over 230 V / 10 A
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Stainless steel housing IP20
Article no. BW1808: AS-i 4I/3O Relay Module with addressing socket, AB Slave
Article no. BW1926: AS-i 4I/4O Relay Module with addressing socket, Single Slave
The status of the in- and outputs is displayed by LEDs. Additionally the both AS-i LEDs (PWR green and AS-i FLT red) show the
status of the AS-i slave as usual for AS-i slaves.
.
Article no.
BW1808
LEDs yellow
state of in-/outputs channel 1 - 4
AS-i voltage OK
LED red (FAULT)
communication error
Other Fieldbussee/
Master Simulators
< 20 mA
Switching threshold of inputs
Inputs 24 V DC
< 0,8 mA (low)
> 5 mA (high)
Outputs
3 relays, change over,
230 V, 10 A
(AC1)
Addressing
4 relays, change over,
230 V, 10 A
(AC1)
additional via addressing socket
Adress
AB slave (up to 62)
Single slave (up to 31)
ID/IO code
7. A. E
7. F. E
Length of connector cables
input: max. 15 m, output: unlimited
Operating voltage
via AS-i
Operating current
AS-i Safety
BW1926
LED green (PWR)
Quiescent current
(Input = 0, Output = 0)
< 200 mA
EMC directions
EN 61 000-6-2
EN 61 000-6-4
Operating temperature
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection category EN 60 529
IP20 (build in)
Dimensions (L / W / H in mm)
120 / 50 / 45
ADDR
AS-i + AS-i –
24 V
I1
Preis Lists
A watchdog function, which switchs the outputs to their currentless switching state if there is no communication on the AS-i circuit, is integrated.
Using the inputs, you can interrogate up to 4 mechanical switching elements. Using the outputs, you can drive up to 4 indicator
lights.
The AS-i Module meets the requirements of the AS-i specification
2.1 and it is a robust housing solution for cabinet mounting for an
AS-i slave.
The board is completely powered by AS-i. The inputs are short
circuit and overload protected. The outputs are change over.
24 V
0V
24 V
24 V
AS-i +
I2
0V
I3
I4
AS-i –
PWR
FLT
I1
O1
I2
O2
I3
O3
I4
O4
PE
K4CM
PE
K4NO
K4NC
K3CM
K2CM
K2NC
K1CM
K3NC
K3NO
K2NO
K1NC
K1NO
ASI+, ASI+24V, 0V
PE
E1 … E4
K1CM … K4CM
K1NO … K4NO
K1NC … K4NC
Programming:
(Bit-setting)
Data bit:
(Input via AS-i)
Bit Function
D0 input I1 /output O1
D1 input I2 /output O2
D2 input I3 /output O3
D3 input I4 /output O4
Parameter bit
Bit Function
P0 not used
P1 not used
P2 not used
P3 not used
Programming:
Address preset 0
Changeable via bus master or
programming devices
AS-i connection
sensor supply, generated out of AS-i
protective ground
24 V inputs
relay common
relay normally open
relay normally closed
Hint:
In article no.: BW1808 the output O4 is not assigned; K4 is not used!
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 108
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module, 2 inputs Pt100
+ 4 digital inputs/outputs in IP67 (M12)
AS-i-Master/Gateways/
Links/Scanner
AS-i Analog Module, 2 inputs Pt100
+ 4 digital inputs/outputs in IP67 (M12)
2 slaves in one housing
• 1 slave with 2 analog inputs PT100
• 1 slave with
- 4 binary inputs
- 4 binary outputs
Protection category IP67
The sensor-interfaces can be supplied by external voltage (according
to PELV) via the black ribbon cable, 1 A max. The resolution of the
analog data is 14 or 12 bit. The connection of the sensors and actuators is done via M12 connectors.
Addressing is done through the addressing socket. Both devices use
extended addressing (AB address).
Article no.
BW2313
Connection
flat cable and M12
AS-i Profile
analog slave: S-7.A.9, ID1=7 (default)
digital slave: S-7.A.7, ID1=7 (fixed)
AS-i voltage
30 V (22 V ... 31,6 V)
Max. AS-i current consumption
80 mA
AUX voltage
24 V (18 V ... 30 V)
Max. AUX current consumption
3A
Number of analog inputs
2
Power supply of analog inputs
AUX voltage
Analog input level
Pt100, 15 ... 400 Ohm
Analog measuring range
-200°C ... +850°C in 0.1° resolution (-2000 ... +8500)
or
-120°C ... +130°C in 0.01° resolution (-12000 ... +13000)
Analog conversion speed
240 ms for both sides
Number of digital inputs
4
Power supply of digital inputs
AUX voltage
Digital input level
U < 5 V: low
U > 15 V: high
Number of digital outputs
4
Power supply of digital outputs
AUX voltage
Max. digital output current
1 A, Σ 3 A max.
Power supply of attached sensors
1 A max.
Analog slave:
Analog input values:
CH0 Temperature AI1
CH1 Temperature AI2
Programming:
(Bit-settings of AS-i parameters)
Bit P0:
1: peripheral fault is indicated
0: peripheral fault is not indicated
Bit P1:
1: 2-wire mode
0: 4-wire mode
Bit P2:
1: -200 °C ... +850 °C / 0,1 °C
0: -120 °C ... +130 °C / 0,01 °C
Bit P3:
not used
Digital slave:
Digital input values:
DI0 Input DI1
DI1 Input DI2
DI2 Input DI3
DI3 Input DI4
Other Fieldbuses/
Master Simulators
The analog module has 2 analog inputs for Pt100 sensors.
The conversion of the measured value and the data transmission via
AS-i occurs according to AS-i Profile 7.A.9. The digital module has 4
binary inputs and 4 binary outputs. Inputs and outputs are completely
galvanically isolated. The ground of the binary outputs is connected
to 0 V ext.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW2313: AS-i Analog Module, 2 inputs Pt100 + 4 digital inputs/outputs in IP67 (M12)
state of Pt100 sensor AI1
LED yellow (AI2)
state of Pt100 sensor AI2
LED yellow (DI1)
state of digital input DI1
LED yellow (DI2)
state of digital input DI2
LED yellow (DI3)
state of digital input DI3
LED yellow (DI4)
state of digital input DI4
LED yellow (DO1-2)
state of digital output DO1 and DO2
LED yellow (DO3-4)
state of digital output DO3 and DO4
LED green (ASI)
no slave has address 0 or peripheral fault
LED red (FLT)
state of slaves
LED green (AUX)
AUX voltage on
Applied standards
EN 61 131-2, EN 61 000-6-2,EN 61 000-6-3
Operating temperature
0°C … +70°C
Storage temperature
-20°C … +85°C
Protection class
IP67
Dimensions (L / W / H in mm)
151 / 60 / 31
Weight
-
Digital output values:
DO0 Output DO1
DO1 Output DO2
DO2 Output DO3
DO3 Output DO4
Programming:
(Bit-settings of AS-i parameters)
Bit P0:
1: watchdog enabled
0: watchdog disabled
Bit P1:
1: 128µs input filter
0: no input filter
Bit P2:
1: synchronous I/O mode disabled
0: synchronous I/O mode enabled
Bit P3:
not used
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 109
Price Lists
LED yellow (AI1)
AS-i Safety
Indicator
AS-i Analog Module, 2 inputs Pt100
+ 4 digital inputs/outputs in IP67 (M12)
Connector / M12
Pin number
2
1
4
3
5
AI1
CH1+
CH1S+
CH1-
CH1S-
Shield
AI2
CH2+
CH2S+
CH2-
CH2S-
Shield
DI1
24 V ext out
DI2
0 V ext out
DI1
nc
DI2
24 V ext out
nc
0 V ext out
DI2
nc
DI3
24 V ext out
DI4
0 V ext out
DI3
nc
DI4
24 V ext out
nc
0 V ext out
DI4
nc
DO1-2
0 V ext out
DO2
0 V ext out
DO1
nc
DO3-4
0 V ext out
DO4
0 V ext out
DO3
nc
ADDR A, ADDR D
Dummy plug, double AS-i hand-held connector behind
Signal Name
Explanation
CHx+
Positive terminal for 2-wire sensors and supply terminal for 4-wire sensors
CHxS+
Positive sense terminal for 4-wire sensors. Not used for 2-wire sensors
CHx-
Negative terminal for 2-wire sensors and supply terminal for 4-wire sensors
CHxS-
Negative sense terminal for 4-wire sensors. Not used for 2-wire sensors
DIx
Digital input x
DOx
Digital output x
24 V ext out
Positive terminal for 2-wire sensors and supply terminal for 4-wire sensors
0 V ext out
Reference sense terminal for 4-wire sensors. Not used for 2-wire sensors
ID1 code definition for the analog slave
ID1
14 bit
12 bit
Channel 1 only
0; 2; 3
1
Channel 1+2
4; 5; 7
(default setting ID1=7)
6
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Connections
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 110
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module, 2 inputs Pt100
+ 4 digital inputs/outputs in IP67 (M12)
State
Signal / Description
Pt100 sensor connected and in range
AI1
(yellow)
no Pt100 sensor connected or sensor out of range
Channel deactivated or module offline
AI2
(yellow)
Pt100 sensor connected and in range
AS-i-Master/Gateways/
Links/Scanner
LEDs
no Pt100 sensor connected or sensor out of range
Input off
Input on
DO1 and DO2 off
DO1-2
(yellow)
DO1 or DO2 on
DO3 and DO4 off
DO3-4
(yellow)
DO3 or DO4 on
no slave has address 0 or peripheral fault
ASI
(green)
at least one slave has address 0 or peripheral fault
both slaves are online and no slave has peripheral fault
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
DI1, DI2,
DI3, DI4
(yellow)
at least one slave has peripheral fault
no AUX voltage present
AUX
(green)
LED flashing
LED off
Price Lists
AS-i Safety
LED on
AUX voltage presentt
Other Fieldbuses/
Master Simulators
at least one slave is offline
FLT
(red)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 111
AS-i 3.0 Universal Module in IP65
AS-i Master/Gateways/
Links/Scanner
Analog and digital inputs/outputs in one module
Mixed input/output slave:
•
•
•
•
2 analog inputs 4 ... 20 mA
1 binary output
1 pulse input
1 status input
Protection category IP65
Price Lists
AS-i Safety
The conversion of the measured value and the data transmission
via AS-i occurs according to AS-i Profile 7.5.5. Inputs are completely galvanically isolated. The ground of the binary output is
connected to 0 V
ext. Analog sensors can be connected via cage clamp terminals.
The sensor-interfaces are supplied by external voltage (according to PELV) via the black ribbon cable, 1 A max. The external
24 V supply voltage must be connected. The resolution of the analog data is 16 bit.
Article no.
BW1931
Analog inputs
Binary outputs
2 inputs 4 ... 20 mA/ 50 Ω
1 output 24 V/ 0,5 A
1 pulse input 0 ... 1kHz, treshold value 13 V
1 status input 0 ... 10 Hz, treshold value 13 V
16 bit
40 mA
40 mA
120 ms for analog inputs
7.5.5
5
F
5
7
Resolution
Max. current per analog input
Range of value
Transformation speed
AS-i Profile
ID code
ID1 code
ID2 code
IO code
Displays
LED green (analog 1)
LED green (analog 2)
LED green (binary output)
LED green (pulse input)
LED green (status input)
LED green (Pwr)
LED red (Fault)
LED green (Aux)
Operating current
Operating voltage
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L / W / H in mm)
Protection category (DIN 40 050)
Bit P0:
1: counter in operation
0: counter set to "0"
Bit P1:
1: upward counting
0: downward counting
Bit P2:
1: Peripheral fault is indicated
0: Peripheral fault is not indicated
Bit P3:
1: scaling (analog values) 4000 … 20000 dec.
0: scaling (analog values) 0 ... 27648 dec.
(Siemens format)
LEDs
analog signal 1
analog signal 2
binary signal
pulse signal
status signal
AS-i voltage
AS-i communication error, peripheral fault
ext. power on (mandatory)
< 80 mA
AS-i (30 V DC)
≥ 500 V
EN 61 000-6-2
EN 61 000-6-4
0°C … +70°C
-25°C … +85°C
housing for DIN-rail mounting
90 / 80 / 70
housing IP65
LEDs
Pwr
Fault
AUX
Digital inputs
Programming:
(Bit-settings of AS-i parameters)
Analog 1
Analog 2
Out
Counter
Status
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1931: Analog and digital inputs/outputs in one module
The analog module has 2 analog inputs 4 ... 20 mA, 1 binary output, 1 pulse input and 1 status input.
Cage clamp terminals
1 2 3 4 5 6
7
8 9 10 11 12
Bit
D0
D1
D2
D3
Function
input status / output 1
input pulse / n.a.
n.a. / n.a.
n.a. / n.a
Bit
A0
A1
A2
A3
Function
input 1
input 2
pulse count
n.a.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 112
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Universal Module in IP65
24 V ext.
7
0 V ext.
2
Sig. + Ch 1
8
Sig. - Ch 1
3
Sig. + Ch 2
9
Sig. - Ch 2
4
Sig. + Pulse
10 Sig. - Pulse
5
Sig. + Status
11 Sig. - Status
6
Sig. + Out
12 0 V Out
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
1
AS-i-Master/Gateways/
Links/Scanner
Connections:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 113
AS-i 4I/4O Module in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
AS-i 4I/4O Module in Stainless Steel
AS-i specification 3.0, AB Slave (up to 62 slaves)
Connection via cage clamp terminal blocks
Inputs and outputs galvanically isolated
Different supply for input and output possible
AS-i Safety
Other Fieldbussee/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Stainless steel housing IP20
Article no. BW1907: AS-i 4I/4O Module in stainless steel
The AS-i 4I/4O Module is the robust housing solution for cabinet
mounting for an AS-i slave.
The inputs and outputs are powered out of separated 24 V each and
are galvanically isolated to the AS-i. Besides they are short-circuit-protected, overload-proof and pole-protected. The status of the
.
Programming:
(Bit-setting)
Article no.
BW1907
Connection
cage clamp terminals
AS-i profile
S-7.A.7, ID1=7 (fixed)
AS-i voltage
18 ... 31,6 V
Max. AS-i current consumption
60 mA
AUX voltage
18 ... 30 V
Max. AUX-I current consumption
1,2 A permanent operation; 4 A max.
Data bit
(Input via AS-i)
Bit Function
D0 input I1 / output O1
D1 input I2 / output O2
D2 input I3 / output O3
D3 input I4 / output O4
Max. AUX-O current consumption
1,2 A permanent operation; 4 A max.
Number of inputs
4
Power supply of inputs
supply out of external 24 V
Parameter bit
Input level
Uin < 5 V: low
Uin > 10 V: high
Bit
P0
P1
P2
P3
Number of outputs
4
Power supply of outputs
supply out of external 24 V
Max. output current
0,5 A permanent operation
Power supply of attached sensors
1,2 A permanent operation
4 x LEDs yellow (I1, I2, I3, I4)
state of inputs I1, I2, I3 and I4
4 x LEDs yellow (O1, O2, O3, O4)
state of outputs O1, O2, O3 and O4
LED green (AUX-I)
supply voltage for inputs on
LED green (AUX-O)
supply voltage for outputs on
LED red (FLT)
flashing: output overload or AUX-I missing
on: module offline
LED green (PWR)
AS-i voltage OK
Applied standards
EN 61 000-6-2, EN 61 000-6-3
Operating temperature
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection class
IP20 (build in)
Dimensions (L / W / H in mm)
120 / 50 / 45
Weight
-
ADDR
AS-i + AS-i –
+24 V I I 1
Preis Lists
in- and outputs is displayed by 8 LEDs. Additionally the AS-i LEDs
(PWR green, FLT red, AUX-I and AUX-O green) show the status of
the AS-i slave as usual for AS-i slaves. A watchdog function, which
switchs the outputs off if there is no communication on the AS-i circuit,
is integrated.
+24 V I I 2
0VI 0VI
+24 V I I 3
+24 V I I 4
AS-i + AS-i –
PWR
AUX-I
FLT
AUX-O
I1
O1
I2
O2
I3
O3
I4
O4
24 V I ext.in
nc
0 V I ext.in
nc
24 V O ext.in
O1
O2
O3
O4
0 V O ext.in
0VO
0VO
0VO
0VO
Function
0 = off/1 = on (watchdog)
0 = on/1 = off (data input filter 128 µs
0 = on/1 = off (synchronous data I/O mode)
not used
Programming:
Address preset 0
changeable via bus master
or programming devices
AS-i +, AS-i -
Connection to the AS-i-Bus
24 V I ext.in,
0 V I ext.in
Supply input for inputs
24 V O ext.in,
0 V O ext.in
Supply input for outputs
+24 V I, 0 V I
Supply output for inputs
0 VO
Supply output GND for outputs
I1, I2, I3, I4
Inputs
O1, O2, O3, O4
Outputs
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 114
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 8I Module in Stainless Steel
AS-i-Master/Gateways/
Links/Scanner
AS-i 8I Module in Stainless Steel
AS-i specification 3.0
AB Slave (up to 62 slaves)
Connection via cage clamp terminal blocks
Inputs galvanically isolated
.
Programming:
Article no.
BW2077
Connection
Cage clamp terminals
AS-i Profile
2 x S-7.A.E, ID1=7 (default)
AS-i voltage
18 ... 31,6 V
Data bit:
(Input via AS-i)
Max. AS-i current consumption
100 mA
Bit
Function
AUX voltage
18 ... 30 V
slave 1
slave 2
Max. AUX current consumption
1,2 A permanent operation; 4 A max.
D0
input I1
input I5
(Bit-setting)
Number of inputs
8
D1
input I2
input I6
Power supply of inputs
supply out of external 24 V
D2
input I3
input I7
Input level
Uin < 5 V: low
Uin > 10 V: high
D3
input I4
input I8
Power supply of attached sensors
1,2 A max.
4 x LEDs yellow (I1, I2, I3, I4)
state of inputs I1, I2, I3 and I4
Parameter bit
Bits:
P0, P1, P2, P3
not used
4 x LEDs yellow (I5, I6, I7, I8)
state of inputs I5, I6, I7 and I8
LED green (AUX)
AUX voltage on
LED red (FLT)
flashing: AUX voltage missing or overloaded
on: module offline
LED green (PWR)
flashing: address is 0
on: AS-i voltage OK
Applied standards
EN 61 131-2, EN 61 000-6-2, EN 61 000-6-3
Operating temperature
0°C … +60°C
Storage temperature
-25°C … +60°C
Protection class
IP20 (build in)
Dimensions (L / W / H in mm)
120 / 50 / 45
Weight
-
Programming:
Address preset 0
changeable via bus master
or programming devices
ADDR 1
ADDR 2
PWR
FLT
AUX
I1
I5
I2
I6
I3
I7
I4
I8
24 V ext.in
I5
0V
0 V ext.in
+24 V
0V
I6
I7
+24 V
+24 V
0V
0V
I8
AS-i +, AS-i -
Connection to the AS-i-Bus
24 V ext.in, 0 V ext.in Supply input for inputs
+24 V, 0 V
Supply output for inputs
I1 - I8
Inputs
+24 V
Preisl Lists
AS-i + AS-i –
+24 V I 1
0V 0V
+24 V I 2
+24 V I 3
0V 0V
+24 V I 4
Other Fieldbusses/
Master Simulators
The status of the inputs is displayed by 8 LEDs. Additionally the
AS-i LEDs (PWR green, FLT red and AUX green) show the status of
the AS-i slaves.
AS-i Safety
Article no. BW2077: AS-i 8I Module in stainless steel
The AS-i 8I Module is a robust stainless steel housing solution for 2
AS-i slaves for cabinet mounting.
The module consists of 2 AS-i AB Slaves. The inputs are powered out
of separated 24 V and are galvanically isolated to the AS-i.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Stainless steel housing IP20
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 115
AS-i 8O Module in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
AS-i 8O Module in Stainless Steel
AS-i specification 3.0
AB Slave (up to 62 slaves)
Connection via cage clamp terminal blocks
Outputs galvanically isolated
Other Fieldbussee/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Stainless steel housing IP20
Article no. BW2078: AS-i 8O Module in Stainless Steel
The AS-i 8O Module is a robust stainless steel housing solution
for 2 AS-i slaves for cabinet mounting.
The module consists of 2 AS-i AB Slaves. The outputs are powered out of separated 24 V and are galvanically isolated to the
AS-i. Besides they are short-circuit-protected, overload-proof
and pole-protected.
The status of the outputs is displayed by 8 LEDs. Additionally the
AS-i LEDs (PWR green, FLT red and AUX green) show the status
of the AS-i slaves.
A watchdog function, which switches the outputs to their currentless switching state if there is no communication on the AS-i circuit, is integrated.
.
Programming:
(Bit-setting)
Article no.
BW2078
8 LEDs yellow
state of outputs channel O1 - O8
LED green (PWR)
AS-i voltage OK
LED red (FAULT)
communication error
Data bit:
(Output via AS-i)
LED green (AUX 1, AUX 2)
AUX voltage on
Bit
Function
Quiescent current (Output = 0)
< 30 mA
Slave 1
Slave 2
Outputs
8, electronic
D0
Output O1
Output O5
Loading capacity
500 mA per output
D1
Output O2
Output O6
Operating voltage
via AS-i
D2
Output O3
Output O7
Operating current
< 80 mA out of AS-i
D3
Output O4
Output O8
EMC directions
EN 61 000-6-2
EN 61 000-6-4
Ambient operating temperature
Parameter bit
Bits:
P0: Watchdog
P1, P2, P3
not used
0°C .. +60°C
Storage temperature
-25°C .. +70°C
Protection category EN 60 529
IP20 (build in)
Dimensions (L / W / H in mm)
120 / 50 / 45
Programming:
Address preset 0
changeable via bus master
or programming devices
Preis Lists
AS-i Safety
IO code
ID code
ID2 code
ADDR 1
AS-i +
0 V 1 ext.in
0V 1
0V 1
0V 1
0V 1
AS-i +
AS-i –
ADDR 2
24 V 1ext.in
O1
O2
O3
O4
AS-i –
PWR
AUX 1
FLT
AUX 2
O1
O5
O2
O6
O3
O7
O4
O8
24 V 1 ext.in 0 V 1 ext.in
24 V 2 ext.in 0 V 2 ext.in
24 V 2 ext.in 0 V 2 ext.in
O5
0V 2
O6
O7
O8
0V 2
0V 2
0V 2
7
A
7
AS-i +, AS-i -
Connection to the AS-i-Bus
24 V1 ext.in
0 V1 ext.in
Supply output for outputs
Outputs O1 - O4
24 V2 ext.in
0 V2 ext.in
Supply output for outputs
Outputs O5 - O8
0 V1
O1 - O4
0 V ext.out, O1 - O4
Reference potential for
outputs O1 - O4
0 V2
O5 - O8
0 V ext.out, O5 - O8
Reference potential for
outputs O5 - O8
O1, O2, ... O8
Outputs O1 - O8
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 116
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Counter Module
AS-i-Master/Gateways/
Links/Scanner
A/B inputs
Profile 7.3 „Plug and Play“
as simple as digital AS-i I/O
High protection category IP65
Different pre-divisors are available, which can be select via AS-i
parameters as well.
With the help of parameters the module can be set to zero as well
as the counting direction can be defined. Es stehen verschiedene
The module reports a peripheral fault at counter overflow (underflow).
Article no.
BWU2218
Inputs
As long as the AS-i parameter for setting zero is set the counting
is stopped. After the setting to zero of the counting value a
pre-divisor or the AS-i parameter for no pre-divisor must be
adjusted again.
BWU2219
1 M12 input (2 channels)
BWU2189
2 M12 inputs (2 x 2 channels)
Voltage supply, sensors
4 M12 inputs (4 x 2 channels)
via AS-i
Range of value
-32768 … 32767 dec. (start value: -30768)
Counting rate
max. 20 kHz
Power supply sensor
max: 150 mA
AS-i profile
7.3
ID code
3hex
ID2 code
Chex
Dhex
IO code
E
7hex
Displays
LEDs geen (In 1 - 4)
state of input 1
state of inputs 1 and 2
state of inputs 1, 2, 3 and 4
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error, peripheral fault
Operating current
< 200 mA
Operating voltage
AS-i (30 VDC)
Other Fieldbuses/
Master Simulators
The AS-i Counter Module has inputs for standard sensors (24 V,
pnp, push-pull). The module counts the impulses with the two
channels (BWU2218), twice two channels (BWU2219) or 4 x two
channels (BWU2189) up- and downwards and outputs the result
as 16 bit value (-32768 … 32767) via AS-i. The start value is
-30768.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BWU2218: Counter Module 2-channel input
Article no. BWU2219: Counter Module 2 x 2-channel input
Article no. BWU2189: Counter Module 4 x 2-channel input
≥ 500 V
Voltage of insulation
EMV
EN 61 000-6-2
EN 61 000-6-4
Ambient operating temperature
0°C … +70°C
-25°C … +85°C
Housing
AS-i Safety
Storage temperature
housing for DIN-rail mounting
Dimensions (L / W / H in mm)
90 / 80 / 43
Protection category DIN 40 050
housing IP65
Pin assignment
In 1
BWU2189
M12 connections
1
24 V out of
AS-i
IR
In 3
Fault
Pwr
In 4
In 3
In 1
In 2
–
2
channel A
In 3
–
–
3
0 V out of AS-i
In 1
In 4
–
–
4
channel B
In 2
In 4
In 2
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 117
Price Lists
BWU2218 BWU2219
AS-i Counter Module
AS-i Master/Gateways/
Links/Scanner
Programming (Bit-setting of AS-i parameters)
BWU2218
Bit P0
Parameter
Bit P1
Parameter
Bit P3
Bit P2
Parameter
1
count upwards In 1
1
counter In 1
1
1
no pre-divisor
0
count downwards In 1
0
set zero In 1
1
0
pre-divisor = 2
0
1
pre-divisor = 8
0
0
pre-divisor = 32
BWU2219
Bit P1 Parameter
Bit P2 Parameter
Bit P3 Parameter
1
count upwards In 1
1
counter In 1
1
count upwards In 2
1
counter In 2
0
count downwards In 1
0
set zero In 1
0
count downwards In 2
0
set zero In 2
BWU2189
Bit P2
Bit P1
Bit P0
Parameter
Bit P3
Parameter
0
0
0
set zero In 1
1
count upwards In 1 ... In 4
0
0
1
set zero In 3
0
count downwards In 1 ... In 4
0
1
0
pre-divisor = 32
0
1
1
set zero In 2
1
0
0
pre-divisor = 8
1
0
1
set zero In 4
1
1
0
pre-divisor = 2
1
1
1
no pre-divisor
Start value:
At power-up, all the counter with 0x87D0 (-30768) are initialized to indicate that there is no zero-setting.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Bit P0 Parameter
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 118
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Counter Module
AS-i-Master/Gateways/
Links/Scanner
1-Channel Input
Profile 7.3 "Plug and Play"
As simple as digital AS-i I/O
High protection category IP65
With the help of parameters the module can be set to start value
as well as the counting direction can be defined.
Article no
BW1723
Input
1 input
With parameter P2 the user can choose between counting impulses or frequency measurement.
As long as the AS-i parameter PØ is set the counting is stopped.
The module reports a peripheral fault at counter overflow (underflow) or when status input is going invalid (low).
Programming:
(Bit-setting of AS-i parameters)
Voltage supply, sensors
via external voltage 24 V
P0 Operation
Range of value
-32768 … 32767 dec. (start value: -32768)
0
set to start value (-32768)
Counting rate
max. 4 kHz
1
normal operation
Power supply sensor (ext. 24V)
max. 700 mA
AS-i profile
7.3
P1 Gate time
ID code
3hex
0
8 s gate time for frequency
ID2 code
Chex
1
1 s gate time for frequency
IO code
7hex
Displays
P2 Mode
LED yellow
state of channel 1
0
impulse
LED green (PWR)
AS-i voltage
1
frequency
LED red (FAULT)
AS-i communication error, peripheral fault
Operating current
< 200 mA
P3 Counting direction
Operating voltage
AS-i (30 V DC)
0
count downwards
Voltage of insulation
≥ 500 V
1
count upwards
EMC
according EN 50 081-2, EN 61 000-6-2
Ambient operating temperature
Storage temperature
0°C … +70°C
-25°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
90 mm, 80 mm, 43 mm
Accessories:
AS-i substructure module to connect 1 AS-i flat
cable, 1 flat cable for additional supply
(art. no. BW1181, see also page 183)
AS-i substructure module to 1 AS-i round cable,
1 round cable for additional supply
(art. no. BW1183, see also page 183)
Protection category (DIN 40 050) housing IP65
Connections:
1
24 V extern
2
channel 1 +, pulse/freq. input
3
0 V extern
4
status input
5
n.c.
Other Fieldbuses/
Master Simulators
The module counts the impulses or frequency up- and downwards with the 1 channel and outputs the result as a 16 bit value
(-32768 ... 32767) via AS-i. The start value is -32768.
AS-i Safety
The AS-i Counter Module has 1 input for standard sensors.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1723: AS-i Counter Module
Price Lists
Connection counter
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 119
AS-i Master/Gateways/
Links/Scanner
AS-i Counter Module (0-15)
1-Channel Input
As simple as digital AS-i I/O
High protection category IP65
AS-i connection via bottom module or M12
Other Fieldbussee/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1711: AS-i Counter Module (0 to 15)
The AS-i Counter Module has 1 input for standard sensors. The
module counts the impulses from (0 … 15) via AS-i. The start value is 0. When reaching the count 15 the module starts at 0 again.
The counter module loads the current value and determines the
number of pulses between two host calls from the difference between this value and the previous.
Article no
BW1711
Inputs
1 input
Voltage supply, sensors
via AS-i
Range of value
0 … 15 dec. (start value: -0)
AS-i Safety
As long as the AS-i parameter for setting zero is set the counting
is stopped.
Programming:
(Bit-setting of AS-i parameters)
P1
P0
not used
Counting rate
max. 769 Hz
P2
Power supply sensor
max. 150 mA
1
normal mode
AS-i profile
S-0.F
0
set zero
ID code
Fhex
IO code
0hex
P3
ID1 code
Fhex
1
count upwards
ID2 code
Ehex
0
count downwards
LED yellow
state of channel 1
LED green (PWR)
AS-i voltage
Accessories:
AS-i substructure module to connect 1 AS-i flat
cable, 1 flat cable for additional supply
(art. no. BW1181, see also page 183)
Displays
LED red (FAULT)
AS-i communication error, peripheral fault
Operating current
< 200 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
≥ 500 V
EMC
according EN 50 081-2, EN 61 000-6-2
Operating temperature
AS-i substructure module to 1 AS-i round cable, 1
round cable for additional supply (art. no. BW1183,
see also page 183)
0°C … +70°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
90 mm, 80 mm, 43 mm
Protection category (DIN 40 050) housing IP65
Connection AS-i
1
AS-i +
2
n.c.
3
AS-i -
4
n.c.
5
n.c.
Connection counter:
Preis Lists
With the help of parameters the module can be set to zero as well
as the counting direction can be defined.
1
24 V out of AS-i
2
input
3
0 V out of AS-i
4
n.c.
5
n.c.
IR
Connection AS-i *
Fault
Pwr
In 1
Connection counter
In 2
* Remark: If you use this connection for AS-i,
do not connect an AS-i cable to the substructure.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 120
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Analog Module: 2 Inputs
for Leuze ODSL 30 Distance Sensors
AS-i-Master/Gateways/
Links/Scanner
2 ODSL Distance Sensors connectable
Connection of the ODSL 30
via M12 sockets
High protection category IP65
Article no. BW1908: 0 ... 65 m
Article no. BW1664: 0 ... 30 m
max. 2 ODSL 30
Voltage supply, sensors
Resolution
via AS-i
7.3
ID code
IO code
1 mm
16 bit unsigned
0 … 32766
1 mm
16 bit signed
0 … 32766
AS-i profile
ID2 code
BW1908
3hex
Dhex
9hex
7hex
Displays
LED green (Analog 1)
state of channel 1
LED green (Analog 2)
state of channel 2
LED green (PWR)
AS-i voltage
LED red (FAULT)
AS-i communication error,
peripheral fault
Operating current
< 250 mA
Operating voltage
AS-i (30 V DC)
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
Protection category (IEC 60 529)
Programming:
(Bit-setting via AS-i parameters)
Bit P0:
1: It is measured on sensor 1
0: Sensor 1 is referencing
Bit P1:
(Bit P1 is not used, if bit P3 = 0)
1: It is measured on sensor 2
0: Sensor 2 is referencing
Bit P2:
1: Peripheral fault is allowed
0: Peripheral fault is not allowed
Bit P3:
1: Sensors 1 and 2 are used
0: Sensor 1 is used only
Settings at the ODSL 30:
Serial menue: Remote Control, Baudrate 19200, Node
Address 0
≥ 500 V
EN 61 000-6-3, EN 61 000-6-2
0°C … +70°C
-25°C … +85°C
housing for DIN-rail mounting
90 mm/ 80 mm/ 70 mm
housing IP65
Accessories:
AS-i substructure module to connect 1 AS-i flat cable,
1 flat cable for additional supply (art. no. BW1181, see
also page 183)
AS-i substructure module to 1 AS-i round cable,
1 round cable for additional supply (art. no. BW1183,
see also page 183)
Connections (M12 socket, 4 pins):
1
+24V
2
RS485 TX+
3
0V
4
RS485 TX-
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Inputs
BW1664
With the help of AS-i parameters the referencing can be started
and the number of the connected ODSL 30 can be set. The peripheral fault is set, if an error occurs two times in succession at
measuring or referencing.
Other Fieldbusses/
Master Simulators
Article no.
The distance sensors are powered out of separated 24 V.
AS-i Safety
2 ODSL 30 can be connected to the module. The measured values are transfered asynchronically to the host according to AS-i
profile 7.3. The distance sensors are connected via 4-pin M12
sockets. The communication between ODSL 30 and the AS-i
module is made by RS 485.
Preisl Lists
Sensor 1 Sensor 2
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 121
AS-i Master/Gateways/
Links/Scanner
AS-i Code Block
AS-i Code Block
Codes from 0 to 255
Adjustment via
2 rotary switches
2 AB Slaves
Other Fieldbussee/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1527 with 2 code switches
With the help of the 2 slaves for example tools (changing AS-i circuits) can be coded from 0 to 255.
transmitted via AS-i and can be proccessed easy in the I/O area
of the controller.
The AS-i Code Block consists of 2 AS-i slaves and 2 rotary
switches with which a value each from 0hex to Fhex (0 to 15 decimal) can be adjusted. The adjusted values of the rotary switches
are connected with the inputs of the AS-i slaves. The codes are
There is a common Fault LED (red) and a green AS-i Power LED.
Additionally there are 2 LEDs for each slave: One for the code
switch (yellow, on when code is not zero) and one for communication error (red).
The AS-i Code Block is equiped with two programming sockets.
Technical data
Article no.
BW1527
Interfaces
AS-i
IO code (slave 1 and 2)
0hex
ID code (slave 1 and 2)
Ahex
ID1 code
Fhex
ID2 code
Ehex
LED red (Fault)
communication error
LED green (PWR)
AS-i voltage OK
LEDs for slave 1 and 2:
1x LED red (Fault 1/Fault 2)
slave 1/slave 2 offline
1x LED yellow (Code 1/Code 2) code switch unequal zero
1x address sockets
for slave 1 and slave 2
Operating current
< 50 mA per slave
Operating voltage
AS-i (30 V DC)
Voltage of insulation
≥ 500 V
EMC directions
EN 61 000-6-2, EN 51 081-2
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
45 mm, 80 mm, 50 mm
Accessories:
• AS-i substructure module to connect 2 AS-i flat cable (Article no. BW1180, see also page 183)
• AS-i substructure module to connect 2 AS-i round cable (Article no. BW1182, see also page 183)
Preis Lists
AS-i Safety
Protection category (DIN 40 050) housing IP65
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 122
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i/AS-i Coupler in IP20
AS-i-Master/Gateways/
Links/Scanner
Connection of 2 AS-i Networks
via 2 internal 4I/4O Slaves
Easy data exchange
between 2 AS-i Networks via
the internal 2 AS-i Slaves
There is a galvanic isolation between both AS-i networks.
Each AS-i slave has got 6 LEDs, 4 LEDs for the 4 outputs, one
power LED and 1 LED for AS-i faults. Furthermore each slave
has got an address socket.
As long as one of both slaves does not exchange data the other
slave reads on each input a 0 as default.
The AS-i/AS-i Coupler consists of two 4I/4O Slaves in one housing. The outputs of one slave are connected to respective inputs
Technical data
Article no.
BW1187
Interfaces
AS-i circuit 1 and 2
IO-Code (slave 1 and 2)
7hex
ID-Code (slave 1 and 2)
Fhex
ID1-Code (slave 1 and 2)
Fhex
ID2-Code (slave 1 and 2)
Ehex
AS-i connections via 4-pin COMBICON plug:
AS-Interface/AS-Interface
Coupler
AS-Interface network 1
AS-Interface
slave 1
LEDs for slave 1 and 2
LED green (power)
AS-i voltage ON
1x LED red (FAULT)
AS-i communication error, peripheral fault
4x LEDs yellow
output 1 up to output 4
2x address socket (ADDR)
for slave 1 and slave 2
Operating current
< 80 mA per slave
Operating voltage
AS-i (30 V DC)
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082, EN 50 081
1
5
2
6
3 4
7 8
AS-i2 AS-i2 AS-i1 AS-i1
+
+
AS-Interface
slave 2
4O
4I
4I
4O
AS-Interface network 2
1
AS-i2-
2
AS-i2+
3
AS-i1-
4
AS-i1+
5
n.c.
6
n.c.
Other Fieldbusses/
Master Simulators
In big applications with more than one AS-i network there is often
a need to exchange data between two AS-i networks, e. g. to report the process status. This problem was solved in the past with
the help of 2 normal AS-i 4I/4O Modules, with the inputs of one
slave connected to the outputs of the other slave. With the use of
the AS-i/AS-i Coupler to solve this problem the installation costs
as well as the components costs can be reduced.
of the other slave and vice versa (AS-i output data bit 0 of the first
slave with AS-i input data bit 0 of the second slave and vice versa, etc.).
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1187
The AS-i/AS-i Coupler provides the easiest solution to exchange
data between two PLCs via AS-i.
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
99 mm, 22,5 mm, 92 mm
7
n.c.
AS-i FAULT
8
n.c.
AS-i FAULT
9
AS-i2+
O0 O1O2O3
10 AS-i211 AS-i1+
ADDR
12 AS-i113 AS-i2+
www.bihl-wiedemann.com
AS-i2 AS-i2 AS-i1 AS-i1
+
+
AS-i2 AS-i2
+
-
9 10
11 12
13 14
15 16
14 AS-i215 n.c.
16 n.c.
Preisl Lists
Protection category (DIN 40 050) housing IP20
AS-i Safety
0°C … +55°C
AS-i 1
Ambient operating temperature
AS-i 2
ADDR
O0 O1O2O3
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 123
Other Fieldbussee/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i/AS-i Coupler in IP65
Connection of 2 AS-i networks
via 2 internal 4I/4O slaves
Easy data exchange
between 2 AS-i networks via
the internal 2 AS-i slaves
High protection class IP65
Article no. BW1280
The AS-i/AS-i Coupler provides the easiest solution to exchange
data between two PLCs via AS-i.
In big applications with more than one AS-i network there is often
a need to exchange data between two AS-i networks, e. g. to report the process status. This problem was solved in the past with
the help of 2 normal AS-i 4I/4O Modules, with the inputs of one
slave connected to the outputs of the other slave. With the use of
the AS-i/AS-i Coupler to solve this problem the installation costs
as well as the components costs can be reduced.
There is a galvanic isolation between both AS-i networks.
Each AS-i slave has got 5 LEDs, 4 LEDs for the 4 outputs and
one power LED. Furthermore each slave has got an address
socket.
As long as one of both slaves does not exchange data the other
slave reads on each input a 0 as default.
The AS-i/AS-i coupler consists of two 4I/4O Slaves in one housing. The outputs of one slave are connected to respective inputs
Technical data
Article no.
BW1280
Interfaces
AS-i circuit 1 and 2
IO-Code (slave 1 and 2)
7hex
ID-Code (slave 1 and 2)
Fhex
ID1-Code (slave 1 and 2)
Fhex
ID2-Code (slave 1 and 2)
Ehex
AS-i connections via yellow AS-i cable
LEDs for slave 1 and 2
2x 4 LEDs yellow
output 1 up to output 4
2 x LED green/red (PWR/FAULT) AS-i voltage/Communication error
2x address sockets
for slave 1 and slave 2
Operating current
< 80 mA per slave
Operating voltage
AS-i (30 V DC)
Voltage of insulation
≥ 500 V
EMC directions
EN 50 082, EN 50 081
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
90 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
housing IP65
Preis Lists
AS-i Safety
of the other slave and vice versa (AS-i output data bit 0 of the first
slave with AS-i input data bit 0 of the second slave and vice versa, etc.).
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 124
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Drive Solutions
Module
Art. No. Characteristic
Cylindrical AS-i Actuator 1I/3O
BW1647
P.
AB slave (up to 62 slaves)
127
AS-i Slave for SEW frequency inverters BW2038
with M12 sockets, protection category IP65
128
AS-i 3.0 Motor Modules
BW2437
AS-i 3.0 4I/4O Module for MOVI-SWITCH
129
BW2398
for 2 Roller Drives, speed setting of AS-i parameter
130
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
BWU2478 for 2 Roller Drives, speed setting of AS-i analog values or 128
rotary switches
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Drive Solutions
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 125
AS-i Master/Gateways/
Links/Scanner
AS-i Drive Solutions
Connection of
variabel speed drives
and motors with integrated
switching and protection
The AS-i - originally designed to network binary sensors and
actuators - offers in combination with the AS-i slaves for frequency inverters and decentralizes frequency inverters frequency inverter motors a posibility to create new plant structures
together with drives. The advantages of AS-i like small costs,
high flexibility, easy handling can be combined with the functionality of frequency inverters and especially frequency inverter
motors as well as with motors with integrated switching and protection function in an efficient way. That concept provides the
user a real alternativ to create new solutions for machines and
plants which were former realized with more powerful fieldbus
systems.
motors is conventionally installed. The parallel wiring starts at the
central cabinet and ends at the particular motors. This means a
big cabinet with all PLC I/O slots as well as all frequency inverters.
Picture 2: Decentral frequency inverter motors communicating
via AS-i
Picture 2 shows a cabeling alternative for the same production
line, with frequency inverters or frequency inverter motors decentral located and communicating via AS-i. In opposite to the parallel power wiring only two cables go through the plant - the AS-i to
transmit the control signals and the power bus.
Picture:1 Traditional concept with parallel wiring
Picture 1 shows a production line with 12 conveyer belts. Each
conveyer belt is variable speed driven. The power cabeling
between frequency inverter and the decentral located
As you can see from this example there are possibilities to minimize the cabinet card, the power cabeling, if AS-i is used in combination with decentral used drives. Further advantages are the
posibility to design modular plant structures, to minimize the
installation time and test time. This all leads to an earlier start of
the production which means less "dead" money.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Application sample
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 126
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Cylindrical AS-i Actuator 1I/3O
AS-i-Master/Gateways/
Links/Scanner
AS-i I/O Module in Stainless Steel Sleeve
Simple networking of standard
actuators with high protection class
via AS-i
1I/3O
Mounting via reduction adapters
into PG or metrical fittings
Article no.
BW1647
Quiescent current (inputs = 1, outputs = 0)
≤ 20 mA
Switching threshold of inputs
≤ 0,5 mA (low)
≥ 0,8 mA (high)
External voltage supply U
18 … 30 V DC (PELV)
Outputs
3 pnp outputs
Loading capacity
20 mA per output
Operating voltage
via AS-i
Operating current
< 30 mA
Voltage of insulation
≥ 500 V
EMC directions
EN 50 081-2,
EN 50 082-2
Ambient operating temperature
0°C … +70°C
Storage temperature
-25°C … +70°C
Protection category EN 60 529
IP67 (mounted)
LED (green/red)
power/AS-i diagnostics
Allowable shock and vibration stress
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Dimensions sleeve
M18x1, length 55 mm
Length of cable
approx. 20 cm
AS-i Connection
M12x1 round connector
Connection:
U+, U- not short circuit protected (max. 1 A)
Accessories: Reduction sleeve M25/M18x1 (Art. no. BW1282)
Reduction sleeve PG16/M18x1 (Art. no. BW1241)
Cable:
- red:
- black:
- yellow:
- orange:
- brown:
- green:
U+
UA1
A2
A3
E1
M12 round connector:
Pin 1: AS-i +
PIn 2: UPIn 3: AS-i PIn 4: U+
Programming
(Bit-setting)
AS-i Data bits
Bit Function
D0 output A1
D1 output A2
D2 output A3
D3 input E1
Parameter bit
Bit Function
P0 not used
P1 not used
P2 not used
P3 not used
Programming:
Address preset 00
changeable via bus master or
programming device
BW1647
IO Code
9
ID Code
A
ID2 Code
E
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 127
Other Fieldbuses/
Master Simulators
The slave is a 1I/3O Module inside a M18 stainless steel sleeve.
It can be mounted via reduction adapters in PG or metrical fit-
tings. This allows a rugged and quick mounting. It is connected to
the AS-i line and the additional 24 V via M12 round connector.
Two LEDs display power and AS-i communication errors. An AS-i
peripheral fault is not indicated.
AS-i Safety
The cylindrical AS-i Actuator enables a simple networking of
standard actuators with high protection class via AS-i.
Price Lists
Article no. BW1647: AB slave (up to 62 slaves)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Additional 24 V
AS-i Slave for Frequency Inverters (M12)
AS-i Master/Gateways/
Links/Scanner
AS-i Slave for SEW Frequency Inverters
Infrared interface for slave addressing
Easy triggering
of fixed frequencies
M12 connectors
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
High protection class IP65
Article no. BW2038:
The AS-i Slave for SEW frequency inverters enables the data exchange and programming of frequency inverters with the help of an
easy connection to AS-i. The AS-i Slave consists of an AS-i 2I
Module as a bus interface and a serial interface to communicate
with the frequency inverter. The MOVILINK protocol of MOVIMOT
Article no.
Serial interface
Initial wiring
Inputs
Voltage supply, sensors
Voltage range
Loading capacity of inputs
Input current high/low
Baud rates
BW2038
RS 485
PNP
2
≤ 13 mA
≥ 5 mA/≤ 1,0 mA
9600 bit/s
Other Fieldbuses/
Master Simulators
state of channel 1
LED yellow (In 2)
state of channel 2
IR
infrared interface
error
LED green (Pwr)
AS-i voltage ON
LED green (Aux)
• error in the inverter
• communication error to the inverter
• short circuit in the sensor supply
24 V power supply ON
Connections:
Pin assignment of the RS 485 interface,
the inputs and the tap of 24 V via M12 sockets:
• The bus address must be set at the Movimot via the
DIP switch "1".
• The tap of the external 24 V is protected via a resetting
fuset
1
2
nc
nc
Connections
AS-i and 24 V
RS 485, 24 V and 2 inputs
AS-i Safety
RS 485 communication active
LED yellow (In 1)
LED red (Fault)
Reasons for peripheral fault (flashing Fault LED):
via 24 V ext.
20 ... 30 V DC
Display
LED green (24 V/RS 485)
is implemented in the AS-i Slave. The AS-i Slave for SEW frequency inverters ist software-compatible to the previous AS-i Slaves for
SEW frequency inverters.
With infrared interface for slave addressing.
electromechanical interface
(piercing technology)
M12 sockets
Operating current
< 80 mA
Operating voltage
AS-i (30 V DC); 18 - 32 V
Voltage of insulation
EMC
Ambient operating temperature
Storage temperature
Housing
Dimensions (L / W / H in mm)
Protection category (DIN 40 050)
3
≥ 500 V
EN 61 000-6-2,
EN 61 000-6-4
BW2038
BW2038
Pin
Connector (1)
Pin
1
24 V ext.
1
Connector (2+3)
0°C … +55°C
2
RS 485 TX -
2
not used
-25°C … +85°C
3
0 V ext.
3
0 V (AS-i)
housing for DIN-rail mounting
4
RS 485 TX +
4
In
90 / 80 / 43
5
FE
5
not used
24 V+ (AS-i)
housing IP65
Price Lists
Accessories:
• AS-i substructure module to connect 1 AS-i flat cable, 1 flat cable for additional supply (Art. no. BW1181)
• AS-i substructure module to connect 1 AS-i round cable, 1 round cable for additional supply (Art. no. BW1183)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 128
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Motor Module
Supply completely out of AS-i
Mixed input/output slave
Single Slave (up to 31 slaves)
Protection category IP67
Article no. BW2437: AS-i 3.0 4I/4O Module for MOVI-SWITCH
Article no.
BW2437
Connection
AS-i: flat cable and piercing, periphery: M12
18 … 31.6 V
Max. AS-i current consumption
400 mA
Number of inputs
4
Power supply of inputs
motor fault inputs: AS-i supply
sensor inputs: AS-i supply
Input level
Uin < 5 V low, Uin > 10 V high
Number of outputs
3
Power supply of outputs
AS-i supply
Max. output current
O1, O3: 10 mA, O4: 350 mA
Supply of motor
out of AS-i, max. 350 mA
Parameter bit
Bit
P0
P1
P2
P3
Function
0 = off/1 = on (watchdog)
0 = on/1 = off (data input filter128 µs
0 = on/1 = off (synchronous data I/O mode)
not used
I3
I I31
Power supply of attached sensors max. 350 mA
I4
Sum of supply current
sensors+motor: max. 350 mA
3x LEDs yellow (I2, I3, I4)
state of inputs I2, I3, I4
1x LEDs yellow (M1)
state of outputs O1
LED green (ASI)
AS-i voltage ON
LED red (FLT)
AS-i communication error, peripheral fault
Applied standards
EN 61 000-6-2
EN 61 000-6-4
Operating temperature
-30°C … +45°C
II 24
I2
II 23
M1
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Protection category
housing IP67
Dimensions (L / W / H in mm)
80 / 45 / 42
Weight
appr. 103 g
Pin 2
M 11
M
ASI
Connections M12
Pin 1
I 3 (input 3)
24 Vout of AS-i I 3
I 4 (input 4)
I4
I4
I 2 (input 2)
I2
I2
M 1 (motor 1)
(O 4)
O1
24 Vout of AS-i (0: 0 V; 1: 24 V)
X (dummy plug)
connection AS-i hand-held
X
FLT
Pin 3
Pin 4
Pin 5
0 Vout of AS-i
I3
not used
I1
(0: 0 V; 1: 24 V)
Other Fieldbuses/
Master Simulators
S-7.F.E, ID1=7 (default)
AS-i voltage
AS-i Safety
AS-i profile
Programming:
(Bit-setting)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 4I/4O Module for MOVI-SWITCH
O3
(0: 0 V; 1: 24 V)
• AS-i substructure module for 4-channel module in 45 mm-housing(art. no. BW2349)
• AS-i substructure module (CNOMO) 4-channel module in 45 mm-housing (art. no. BW2350)
• Protection caps for not used M12 sockets (art. no. BW2368)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 129
Price Lists
Accessories:
AS-i 3.0 4I/4O module for each two Interroll motors
(EC200, EC300 or EC310) with 2 binary and 2 analog outputs
Mixed input/output slave
Protection category IP67
Article no BW2398: AS-i 3.0 Motor Module for 2 Roller Drives,
speed setting of AS-i parameter
The BW2398 is a control module for up to 2 roller drives (e. g. Interroll EC300). The module uses an AS-i AB slave for transmitting rotary information. the speed is defined using AS-i
Article no.
parameters. Up to 2 motors and 2 sensors can be connected to
the module. The motors are powered by 24 Vext and the sensors
by AS-i. The module is 35 V fixed and brake resistor compatible.
BW2398
Connection
AS-i: Flat cable and piercing, periphery: M12
AS-i Profile
S-7.A.7, ID1 = 7 (fixed)
AS-i voltage
18...31,6 V
Max. AS-i current consumption
200 mA
AUX voltage
18 … 30 V
Max. AUX current consumption
8 A continuously, 11 A peak
Number of inputs
4
Power supply of inputs
Motor fault inputs: external supply
Sensor inputs: AS-i supply
Input level
Uin < 5 V low, Uin > 10 V high
Number of binary outputs
2
Power supply of outputs
24 V (AUX, galvanically isolated)
Overvoltage tolerated by reaction 35 V-resistant
brake resistor compatible
Max. output current
10 mA each
Number of analog outputs
2
Range of value
0 ... 10 V
Supply of motors
out of AUX, 4 A continuously, 5.5 A max.
Power supply of attached sensors 120 mA
AS-i voltage ON
LED red (FLT)
AS-i communication error, peripheral fault
LED green (AUX)
24 VDC AUX on
Voltage of insulation
≥ 500 V
Applied standards
EN 61 000-6-2
EN 61 000-6-4
Operating temperature
0°C … +70°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN-rail mounting
Protection class
housing IP67
Dimensions (L / W / H in mm)
80 / 45 / 42
Weight
-
42
45
7
LED green (ASI)
AS-i
66
state of outputs O1, O 3
24V
I1
I2
M1
M2
ADDR
7
state of inputs I1, I2
2x LEDs yellow (M1, M2)
80
2x LEDs yellow (I1, I2)
7
31
7
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 Motor Module
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 130
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 Motor Module
3
5
2
4
Connections M12
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
I 1 (input 1)
24 Vout of AS-i
I1
0 Vout of AS-i
I1
shield
I2
I 2 (input 2)
1
24 Vext in
M 1 (motor 1)
O2
(0: 0 V; 1: 24 V)
O4
(0: 0 V; 1: 24 V)
M 2 (motor 2)
ADDR
I2
0 Vext in
I3
(0: 0 V; 1: 24 V)
O 1 analog-value
I4
(0: 0 V; 1: 24 V)
O 3 analog-value
connection for AS-i hand-held
AS-i-Master/Gateways/
Links/Scanner
Terminal assignment
Configuration analog-value O1/O3
0
1
0
1
0
1
0
1
P1
P2
0
0
0
0
1
0
1
0
0
1
0
1
1
1
1
1
O1/O3
Pin 5
0
0V
1
2,42 V
0
0V
1
2,65 V
0
0V
1
2,90 V
0
0V
1
3,24 V
0
0V
1
3,70 V
0
0V
1
4,26 V
0
0V
1
4,98 V
0
0V
1
6V
0,13 m/s
0,19 m/s
0,27 m/s
0,37 m/s
0,51 m/s
0,68 m/s
0,89 m/s
1,2 m/s
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
P0
Pin
Function
DI0
I1
Input I1
DI1
I2
Input I2
DI2
I3
State (motor-error) motor 1
DI3
I4
State (motor-error) motor 2
DO0
O1
Start/Stop motor 1
DO1
O2
Direction of rotation motor 1
DO2
O3
Start/Stop motor 2
DO3
O4
Direction of rotation
Other Fieldbuses/
Master Simulators
Bit assignment
Data bit
Accessories:
Price Lists
AS-i Safety
• AS-i substructure module for 4-channel module in 45 mm-housing (article no. BW2349, see also page 301)
• AS-i substructure module (CNOMO) for 4-channel module in 45 mm-housing (article no. BW2350, see also page 301)
• Protection caps for not used M12 sockets (article no. BW2368, see also page 186)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 131
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 Motor Module
AS-i module for two motors e.g. Interroll (EC200,EC300 or EC310)
Itoh Denki series 50XE/XP - POWER MOLLER (R) BRUSHLESS 24VDC etc.
2 slaves in one module
• 1 Single Slave with 2 analog outputs 0 ... 10 V
- 2 binary outputs
- 2 binary inputs
• 1 AB Slave with
- 4 binary inputs
- 4 binary outputs
Mixed in- and output slave
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP67
Article no. BWU2478: AS-i 3.0 Motor Module for 2 Roller Drives,
speed setting of AS-i analog values or rotary switch
The BWU2478 is a control module for up to 2 roller drives (e.g.
Interroll EC300). The module uses an AS-i AB slave for transmitting rotary information. The speed is pre-assigned using a rotary
switch or entered as an analog value over AS-i. Up to 2 motors
and 4 sensors can be connected to the module. The motors are
powered by 24 Vext and the sensors by AS-i. The module is
35 V-resistant and brake resistor compatible.
Article No.
BWU2478
Connection
AS-i Profile
AS-i: flat cable and piercing, peripheral: M12
digital slave S-7.A.7, analog slave S-7.5.5,
ID1=7
ID1 = F
18 … 31.6 V
200 mA
8 A continuously, 11 A peak
4
sensor inputs: AS-i power supply
Uin < 5 V low, Uin > 10 V high, 3KΩ
AS-i voltage
Max. AS-i current consumption
Max. AUX current consumption
Number of inputs, sensors
Power supply of inputs
Input level
Number of outputs
Power supply of outputs
Overvoltage tolerated by reaction
Max. output current
Supply of the motors
Power supply of attached sensors
4x LEDs yellow (I1, I2, I3, I4)
2x LEDs yellow (M1, M2)
LED green (ASI)
LED red (FLT)
LED bicolour:
green (AUX)
red (AUX)
Voltage of insulation
Applied standars
Ambient operating temperature
Storage temperature
Housing
Protection category
Dimensions (L / W / H in mm)
Weight
4 digital + 2 analog
24 V (AUX, galvanically isolated)
35 V-resistant
brake resistor compatible
each 500 mA (digital), each 10 mA (analog)
out of AUX, 3 A continuously, 6 A max.
< 100 mA (sum)
state of inputs I1, I2, I3, I4
state of motors M1, M2
AS-i voltage ON
AS-i communication error, peripheral fault
AUX voltage on and OK
AUX voltage on, < 18 V
≥ 500 V
EN 61 000-6-2
EN 61 000-6-4
0°C … +55°C
-25°C … +85°C
housing for DIN-rail mounting
housing IP67
151 / 60 / 30,5
-
Analog slave:
Analog output 0...10 V:
(0 ... 10 000 dec.)
A01: analog value 1 motor 1 / motor 2 *1
A02: analog value 2 motor 1 / motor 2 *1
Digital outputs:
D2 = A01/A02 motor 1 (O5)*1
D3 = A01/A02 motor 2 (O6)*1
Digital inputs:
D0 = M1 disturbance input (I5)*2
D1 = M2 disturbance input (I6)*2
Object ramp
adjustable up to 37,5 s
from 0 V to 10 V
Digital slave:
Digital input values:
D0 input I1
D1 input I2
D2 input I3
D3 input I4
Digital ouput values:
D0 M1 start output (O1)*2
D1 M1 rotating direction (O2)
D2 M2 start output (O3)*2
D3 M2 rotating direction (O4)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 132
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Programming instructuions
*1
with the help of the bits D2 and D3 of the analog slaves can be controlled, which analog value has an effect on which engine.
This function depends on the rotary switch position.
*2
pin 4 of the M1/M2 connections can be used as start output, or alternatively used as a disturbance input (depending on the
rotary switch position). To use the input, the start the output (digital slave, output D0/D2) must be set to be inactive.
set the start output () inactive
LEDs
State
M1, M2
Signal / Description
status M1/M2
(vellow)
Rotary switch
I1, I2,
I3, I4
input off
(yellow)
input on
ASI
no slave address is ’0’ or peripheral fault
FLT
slave online and no peripheral fault
(red
at least one slave offline or address is ’0’
at least one slave has a peripheral fault
(no +24 V)
AUX
AUX voltage not present
(red/green)
LED on
2
5
AUX voltage too low (< 18 V)
Rotary switch 1 = motor 1
Rotary switch 2 = motor 2
AUX voltage OK, however at limit
(18 V ... 22 V)
Rotary switch position 0 - 1:
Values of analog slave for voltage and ramp
AUX voltage OK
Rotary switch position 2 - F:
Selection of preset voltages
LED flashing
LED off
4 Connections M12 Pin 1
I1 (input I1)
1 I2 (input I2)
24 V out of AS-i
I3 (input I3)
I4 (input I4)
M1 (motor 1)
24 V ext out
M2 (motor 2)
ADDR
Pin 2
-
Pin 3
GND
rotating direction 0 V ext out
Pin 4
I1
I2
I3
I4
Start output /
disturbance input *2
Pin 5
-
Other Fieldbuses/
Master Simulators
at least one slave address is ’0’ or
peripheral fault
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Rotary switch
Analog output 0 ... 10 V
connection for AS-i addressing device
Price Lists
Accessories:
• AS-i substructure module (CNOMO) for 8-channel module in 60 mm-housing (article no. BW2351)
• Protection caps for unused M12 sockets (article no. BW2368)
AS-i Safety
(green)
3
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 Motor Module
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 133
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 134
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Building Automation
P.
BW2375
for connection of EnOcean wireless sensors,
housing: white, AB Slave, AS-i Specification 3.0
BW2473
for connection of EnOcean wireless sensors,
housing: black, AB Slave, AS-i Specification 3.0
BW2028
supplied by AS-i, AS-i Specifications 2.1/3.0
137
BW2080
supplied by AS-i, meets requirements for Switzerland
(JGBSK), AB Slave, AS-i Specifications 2.1/3.0
139
AS-i Module for controlling 230 V
blinds
BW2114
supplied by AS-i, 2 AB Slaves,
AS-i Specifications 2.1/3.0
141
AS-i 4I OEM Module for building
services engineering
BW2388
4I AB Slave potted, for use in round flush-mounted
boxes
143
AS-i 2I/2O OEM Module for building
services engineering
BW2389
2I/2O AB Slave with relais output 230 V/5 A, supplied
by AS-i, potted, for use in round flush-mounted boxes
144
AS-i Modules for building services
engineering
BW2137
4I/4O, AB Slave with spring-type terminal,
AS-i Specification 3.0
145
BW2138
4O, Single Slave with spring-type terminal,
AS-i Specification 3.0
BW2139
4I/3O, AB Slave, with spring-type terminal,
AS-i Specification 3.0
BW2175
4I/4O, Single Slave with spring-type terminal,
AS-i Specification 3.0
BW2466
4I, Single Slave with spring-type terminal,
AS-i Specification 3.0
BW2406
For controlling up to 8 MP Bus participants
146
(e.g. Belimo), MP Bus Master, integrated power supply
with overtemperature protection, AS-i 3.0 Single Slave,
protection category IP54
AS-i Module for controlling damper
actuators
Price Lists
AS-i MP Bus Gateway
136
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i EnOcean Slaves
Art. No. Characteristic
Other Fieldbuses/
Master Simulators
Module
AS-i Safety
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview - AS-i Building Automation
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 135
AS-i EnOcean Slave
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Module for connection of EnOcean wireless sensors
AS-i AB Slave
AS-i Specification 3.0
Up to 780 EnOcean Slaves per AS-i circuit
Special colors and various designs available
Article no. BW2375: Housing white
Article no. BW2473: Housing black
The AS-i Slave for connection of EnOcean wireless sensors and
wireless actuators meets the requirements of AS-i
Specification 3.0. Up to 20 AS-i EnOcean Slaves to an AS-i circuit can be connected, each of which max. 31 PTM switching
modules and 8 EnOcean sensors or actuators may be assigned.
The signals of the 31 switching modules are transmitted in real-time not exceeding than 5 ms in the control. There is no switching delay as in other systems. The AS-i conductor can be
connected via spring clamp terminals. Function LEDs indicate
Article no.
The visually appealing housing is suitable for installation in the
visual range also in intermediate ceilings or intermediate bottoms.
Upon request, all housing colours and ornaments, including root
wood or stainless steel, are possible.
BW2375
BW2473
Connections
AS-i
Programming
(Bit Setting)
spring clamp terminals
Parameter bit
26,5 ... 31,6 VDC
Bit P1, P2, P3:
not used
Properties
Operating voltage
≤ 30 mA
Quiescent current consumption
(inputs = 0, outputs = 0)
Other Fieldbuses/
Master Simulators
the respective operating condition. EnOcean switches can be assigned both locally and via the controller a certain AS-i Module.
Max. current consumption
Programming:
Address preset 0
changeable via bus masterprogramming device
54 mA
Switch power supply
by AS-i
Voltage range
18 ... 30 VDC
Displays
LED green (Pwr)
LED red (Fault)
LED yellow
LED on: voltage at the AS-i clamps is on
LED flashing: voltage at the AS-i clamps, but slave
is on addr. 0 (delivery status)
LED on: slave is not in cyclic
data exchange (communication error)
an EnOcean telegram is received
AS-i Safety
Conformity to standards
EMC
EN 61 000-6-2
EN 61 000-6-4
AS-i Profile
S-7.38+S-7.A.5
Housing
Ambient operating temperature
0°C ... +55°C
Operating temperature
-25°C ... +85°C
Protection category
IP 40
Housing
plastic
Colour
white
black
72 / 72 / 51
Price Lists
Dimensions (L / W / H in mm)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 136
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Module for controlling damper actuators
and for detection the damper position
Runtime monitoring of the damper motor in master possible
Connection by external flat cable terminal via insulation penetration technology
AS-i Specifications 2.1/3.0
AS-i-Master/Gateways/
Links/Scanner
AS-i Module to control damper actuators
Connections
Damper actuator
cage clamp terminals or
Belimo-compatible connectors
AS-i
cage clamp terminals
Properties
Achievement
4 inputs / 2 outputs
Output function
transistor PNP
Operating voltage
26,5 ... 31,6 VDC
Quiescent current
(Inputs = 0, Outputs = 0)
≤ 20 mA
Max. current consumption incl.
motor
≤ 420 mA
Short-circuit proof
yes
Protective circuit of inputs
DC PNP
Sensor supply
by AS-i
Voltage range
18 ... 30 VDC
Switching threshold of inputs
≤ 0,8 mA (low); ≥ 5 mA (high)
U
18 … 30 VDC
Loading capacity
400 mA per output
(sum of all outputs ≤ 400 mA) out of AS-i
I/O configuration
7
ID code
D
Displays
Operating
LED green
Function
LED yellow
Inputs 1 - 4
4 x LEDs yellow
Outputs 1 - 2
2 x LEDs yellow
Programming (Bit-setting)
Data bit (input via AS-i)
Bit Function
D0 Input I1
(damper closed)
D1 Input I2
(damper open)
D2 Input I3
(external contackt)
D3 Input I4
(reserved)
D0 Output O1
(damper open up)
D1 Output O2
(reserved)
Parameter bit
Bit Function
Bit P3:
1: Peripheral fault is indicated
0: Peripheral fault is not indicated
Bit P1, P2 :
not used
Programming:
preset: address 0
changeable via busmaster-programming
devices
Accessories:
• Connecting cable 40 cm with M12 plug
(art. no. BW2065)
• AS-i passive distributor, AS-i flat cable on
M12 (art. no. BW1239, see also page 182)
• AS-i passive distributor, AS-i/24 V on M12
(art. no. BW1976, see also page 182)
Other Fieldbuses/
Master Simulators
BW2028
AS-i Safety
Article no.
The connections are short-circuit -and overload protected. A
watchdog function, which switches the outputs to their currentless
switching state if there is no communication on the AS-i circuit, is
integrated. The transfer function is permanent monitored in the integrated AS-i Slave and in the AS-i Master.
This module can be connected via cage clamp terminals or ready
to plug via Belimo-compatible connector.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW2028: Supplied by AS-i
The AS-i module to control damper actuators meets the requirements of the AS-i Specifications 2.1/3.0. It is used to control the
damper actuator and detect the damper position damper open
and damper close as well as the intermediate position „damper
opens“ or „damper closes“. In addition external contact can be
requested, e.g. of an smoke detector or an temperature switch.
Standard conformity
EMC
EN 61 000-6-2, EN 61 000-6-3, EN 61 000-6-4
AS-i profile
S 7. D
Operating temperature
-25°C … +60°C
Storage temperature
-40°C … +70°C
Protection category
IP 54
Housing
synthetic material
Dimensions (L / W / H in mm)
160 / 90 / 55
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 137
Price Lists
Housing
AS-i Module to control damper actuators
AS-i Master/Gateways/
Links/Scanner
Terminal connections:
X4
X3
AS-i-Modul
2 1
X5
In 3
In 4
2
AS-i –
+24 V
+24 V
3
In 2
X5
4
+24 V
S4
5
In 1
S2
6
+24 V
S1
7
In 4
8
+24 V
9
Out 1
2
10
0V
1
11
Out 2
12
0V
S6
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
1 2
X2
AS-i +
1
X2
X1
X1
1
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 138
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Module for controlling damper actuators
and for detection the damper position
Meets requirements for Switzerland (JGBSK)
AB Slave (up to 62 slaves)
Runtime monitoring of the damper motor in master possible
Connection by external flat cable terminal via insulation penetration technology
AS-i-Master/Gateways/
Links/Scanner
AS-i Module to control damper actuators
AS-i
Properties
Achievement
Output function
Operating voltage
Quiescent current
(Inputs = 0, Outputs = 0)
Max. current consumption incl.
motor
Short-circuit proof
Protective circuit of inputs
Sensor supply
Voltage range
Switching threshold of inputs
U
Loading capacity
I/O configuration
ID-Code
Displays
Operating
Function
Inputs 1 - 3
Outputs 1 - 2
Standard conformity
EMC
AS-i profile
Housing
Operating temperature
Storage temperature
Protection category
Housing
Dimensions (L / W / H in mm)
cage clamp terminals or
Belimo-compatible connectors
cage clamp terminals
3 inputs / 2 outputs
transistor PNP
26,5 ... 31,6 VDC
≤ 20 mA
≤ 420 mA
yes
DC PNP
by AS-i
18 ... 30 VDC
≤ 0,8 mA (low); ≥ 5 mA (high)
18 … 30 VDC
400 mA per output
(sum of all outputs ≤ 400 mA) out of AS-i
7
A
LED green
LED yellow
3 x LEDs yellow
2 x LEDs yellow
EN 61 000-6-2, EN 61 000-6-3, EN 61 000-6-4
S 7.A
Programming
(Bit-setting)
Data bit (Input via AS-i)
Bit Function
D0 Input I1
(damper closed)
D1 Input I2
(damper open)
D2 Input I3
(external smoke detectorcontact closed)
D0 Output O1 (damper open up)
D1 Output O2 (reserved)
Parameter bit
Bit Function
Bit P3:
1: Peripheral fault is indicated
0: Peripheral fault is not indicated
Bit P1, P2:
not used
Programming:
preset: address 0
changeable via busmaster-programming
devices.
Accessories:
• Connecting cable 40 cm with M12 plug
(art. no. BW2065)
• AS-i passive distributor, AS-i flat cable on
M12 (art. no. BW1239, s. page 182)
• AS-i passive distributor, AS-i/24 V on M12
(art. no. BW1976, s. page 182)
-25°C … +60°C
-40°C … +70°C
IP 54
synthetic material
160 / 90 / 55
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 139
AS-i Safety
Connections
Damper actuator
BW2080
Price Lists
Article no.
switching state if there is no communication on the AS-i circuit, is
integrated. An integrated AB slave allows to control up to 62
slaves.
The transfer function is permanent monitored in the integrated
AS-i Slave and in the AS-i Master. This module can be connected
via cage clamp terminals or ready to plug via Belimo-compatible
connector.
The module is equipped with advanced diagnostic capabilities and
is able, by an short circuit at the outputs, to trigger a peripheral error message in the master.
Other Fieldbuses/
Master Simulators
Article no. BW2080: Supplied by AS-i
The AS-i module to control damper actuators meets the requirements of the AS-i Specifications 2.1/3.0. It is used to control the
damper actuator and detect the damper position damper open
and damper close as well as the intermediate position „damper
opens“ or „damper closes“. In addition external contact can be
requested, e.g. of an smoke detector or an temperature switch.
O1 to the output can be connected in series with a smoke detector
and an external fusible link. If they are not connected, the contacts
have to be each bridged.
The connections are short-circuit -and overload protected. A
watchdog function, which switches the outputs to their currentless
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Specifications 2.1/3.0
AS-i Module to control damper actuators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Terminal assignment:
X1
X2
X3
X4
X5
1
AS-i +
SD A
+24 V
Out 0
In 3
X6
FL A
2
AS-i +
0V
+24 V
0V
+24 V
FL B
3
AS-i –
SD B / In 2 nc
4
AS-i –
+24 V
X6
Out 1
X4
X3
AS-i-Modul
nc
5
In 1
In 0
6
+24 V
In 1
7
In 0
8
+24 V
9
In 3
10
+24 V
11
Out 0
12
0V
Variants with bridges:
13
Out 1
14
0V
• 1-11: no smoke detector connected
no fusible link X6 connected
X1
SD = smoke detector, FL = fusible link
8
6
4
2
7
5
3
1
X5
14
12
10
8
6
4
2
13
11
9
7
5
3
1
X2
• 1- 3: no smoke detector connected
Attention: The controller can not recognize that by law
bridges smoke detectors or fusible link are
missing.
Circuit diagram:
Smoke detector
Fusible link
damper actuator
Outp. 0
Inp. 2
Connection diagram:
Smoke detector
A
B
24 V 0 V
Damper actuator
Cage clamp terminal
X2
for ext. smoke detector
1
SD A
3
SD B
4
X6
X4
Outp. 1
2
24 V 0 V
A
B
0V
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Plug for ext. fusible link
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 140
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Module for controlling 230 V blinds
AS-i-Master/Gateways/
Links/Scanner
AS-i Module for controlling 230 V blinds
2 AS-i AB Slaves
AS-i Specifications 2.1/3.0
Article no.
Connections
Blinds and 230 V supply
AS-i / switch
Properties
Specification
Inputs
Outputs
Output function
Operating voltage
A watchdog function, which switches the outputs to their currentless switching state if there is no communication on the AS-i circuit, is integrated. On the board there are two 2 AS-i slaves, so
that two blinds can be controlled. Both slaves also have an addressing socket.
BW2114
Programming
(Bit setting)
cage clamp terminals
cage clamp terminals
Data bit (Input via AS-i)
Bit Function
D0 Input I3
(trip recognition)
D1 Input I4
(end position
from 1 detection)
D2 Input I1
(switch up)
D3 Input I2
(switch down)
2 x 4 inputs / 2 x 2 outputs
each with 2 inputs for connecting external
switches (up/down), 2 inputs are used internally
each with 2 relay outputs for connecting
the blind motors with 4- or 5-conductors
Relay
26,5 ... 31,6 VDC
D0 Output O1 (motor down)
D1 Output O2 (motor up)
Quiescent current
(inputs = 0, outputs = 0)
Max. current consumption
≤ 30 mA
Parameter bit
Imax ca. 130 mA
Wiring of the inputs
Switch current supply
Voltage range
switch contacts
by AS-i
18 ... 30 VDC
Bit P1, P2, P3:
not used
Switching current of inputs
Load capacity
4 mA
230 VAC, 4 A each output
Programming:
preset: address 0
changeable via
busmaster-programming devices
Other Fieldbuses/
Master Simulators
The AS-i module to control blinds meets the requirements of the
AS-i Specifications 2.1/3.0. It is used to control 230 V blinds with
4-conductor- or 5-conductor connections. The two inputs can be
used to provide the switch position to the controller. Motors that
turn off automatically when reaching the end-position have to be
used.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW2114: Supplied by AS-i
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 141
Price Lists
LED on: voltage at the AS-i clamps
LED flashing: voltage at the AS-i clamps, but
slave on addr. 0 (default settings)
LED red (Fault)
LED on: slave is not in the cyclic
data exchange (communication error)
2 x LEDs yellow (state: In 1, In 2) LED on: switch closed
Standard conformity
EMV
EN 61 000-6-2
EN 61 000-6-4
AS-i profile
S-7.A.E
Housing
Operating temperature
-25°C … +60°C
Storage temperature
-40°C … +70°C
Protection category
IP 54
Housing
synthetic material
Dimensions (L / W / H in mm)
160 / 90 / 55
AS-i Safety
Displays
LED green (Pwr)
AS-i Module for controlling 230 V blinds
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Connections:
BW2114
X4
1
1
X3
1
ASI+
2
ASI+
7
ASI–
8
ASI–
1↑
1↓
1↓
2↑
2↓
2↓
3
4
5
6
+24V_ext +24V_ext +24V_ext +24V_ext
9
In_23
10
In_22
11
In_13
13
L
6
PE
12
PE
5
1
12
In_12
11
1 2
4
1 1
10
N
3
N
9
PE
2
2
8
2 2
1
2 1
X3
: Motor 1 up
1: Motor 1 down
2: Motor 1 down 2
: Motor 2 up
1: Motor 2 down 1
2: Motor 2 down 2
Motor limit switch as AS-i signals:
Motor 1= Slave 1
Position
Trip to the top (output 1)
Trip to the bottom (output 0)
Input In 10
Input In 11
Input In 10
Input In 11
Top
0
0
0
1
Centre
1
1
1
1
Bottom 1
1
0
1
0
Bottom 2
0
0
0
0
Motor 2= Slave 2
Position
Trip to the top (output 1)
Trip to the bottom (output 0)
Input In 20
Input In 21
Input In 20
Input In 21
Top
0
0
0
1
Centre
1
1
1
1
Bottom 1
1
0
1
0
Bottom 2
0
0
0
0
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
14
N
7
PE
X4
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 142
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 4I OEM Module for
building services engineering
AS-i-Master/Gateways/
Links/Scanner
AS-i 4I OEM Module for
building services engineering
For use in round flush-mounted boxes
Potted
AB Slave (up to 62 slaves)
BW2388
Connection
via connecting wire
AS-i profile
S-7.A.7
AS-i voltage
22 ... 31,6 V
Number of inputs
4
IO Code
7
ID Code
A
ID1 Code
7
ID2 Code
7
Current supply of sensors out of AS-i
Operating current IB
< 50 mA
Operating voltage
out of AS-i (30 V) PELV,
out of AS-i Power24V PELV
4 x LEDs yellow
state of inputs
LED red (FAULT)
LED on:
AS-i communication error
LED flushing: AS-i peripheral fault, e. g. no 24 V or short circuit
at an input, fuse
LED green (PWR)
LED on:
voltage at the AS-i clamps
LED flushing: error, e. g. slave on adress 0 (state of delivery) or
peripheral fault
Length of connector line
ca. 25 cm
EMC
EN 61 000-6-2
EN 61 000-6-3
EN 61 000-6-4
Operating temperature
-25°C ... +70°C
Storage temperature
-40°C … +70°C
Protection category
IP00
Programming:
(Bit-setting)
Data bit
BitFunction
D0 Input 1
D1 Input 2
D2 Input 3
D3 Input 4
Addressing
Addresse preset 0
Dimensions (D / H in mm) 50 / /
Length of cable
max. 1,5 m
Price Lists
Weight
Other Fieldbuses/
Master Simulators
Article number
Switches or buttons can be directly clamped to the connection.
The module can be connected to location AS-i PELV voltage and
as well as to AS-i Power24-PELV voltage .
AS-i Safety
This 4I Module is mainly used in building automation. It is an AS-i
Slave with four inputs, the switches, buttons or two-wire sensors
can be connected directly. The round module is potted and suitable to install in standard flush-mounted or junction boxes.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW2388: AS-i 4I OEM Module for building services engineering
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 143
AS-i Master/Gateways/
Links/Scanner
AS-i 2I/2O OEM Module for
building services engineering
AS-i 2I/2O OEM Module for
building services engineering
AB Slave (up to 62 slaves)
Potted
Circuit board supplied by AS-i
Output 230 V 5 A
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Specifications 2.1/3.0
Article no. BW2389: AS-i 2I/2O OEM Module for building services engineering
This relay module is an AS-i Slave with two inputs and two outputs for building services engineering. The outputs are 400 V relays, which are also suitable for controlling motors. To the inputs
can be connected directly switches, buttons or two-wire sensors.
Article no.
BW2389
Connection
connecting wire
AS-i profile
S-B.A.E
AS-i voltage
22 ... 31,6 V
Max. AS-i current consumption
50 mA
Number of inputs
2
Power supply of inputs
AS-i
Input level
≤ 0,8 mA (low), ≥ 5 mA (high)
Outputs (relay) switched to the
motor control
2
Switching state: OFF
I < 1 mA
Switching state: ON
I < 3 mA
Switching voltage of the relays
max. 380 V DC / 400 V AC
Switching current of the relays
max. 10 A per output
Current supply of sensors
out of AS-i
Operating current
< 85 mA
The round module is potted and can be installed in standard
flush-mounted or junction boxes. The wires are connected with
cage clamp terminal blocks.
Operating voltage
via AS-i (30 V) PELV/AS-i Power 24 PELV
4 x LEDs yellow
state of the in -and outputs
LED red (FAULT)
communication error
LED green (PWR)
AS-i voltage OK
EMC
according to EN 50 082
EN 50 081
Operating temperature
Storage temperature
Programming:
(Bit-setting)
Data bit-setting
Bit
D0
D1
D2
D3
Function
Output 1
Output 2
Input 1 (I1)
Input 2 (I2)
Programming:
address preset 0
0°C … +60°C
-25°C … +70°C
Protection category
IP00
Dimensions ( D / H in mm)
50 / 20
Length of cable
max. 1,5 m
Price Lists
Weight
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 144
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Module for
building services engineering
Article no. BW2137: 4 inputs/4 outputs, AS-i AB Slave
Article no. BW2138: 4 outputs, AS-i Single Slave
Article no. BW2139: 4 inputs/3 outputs, AS-i AB Slave
Article no. BW2175: 4 inputs/4 outputs, AS-i Single Slave
Article no. BW2466: 4 inputs, AS-i Single Slave
with up to 500 mA (outputs). If bus communication is interrupted
(master failure), the outputs are switched to their currentless
switching state by the watchdog. Connection by spring-type terminals. Installation by external fastening tabs.
The AS-i 4I/4O Module, which meets the requirements of the new
AS-i Specification 3.0 is the board based solution for an AS-i
slave with 4 inputs and 4 outputs.
The inputs and outputs are powered out of separated 24 V. They
are short circuit and overload protected and can each be loaded
Article no.
BW2137 BW2138 BW2139 BW2175 BW2466
Connection
cage clamp terminals
≤ 20 mA
Quiescent current
(Input = 0, Output = 0)
U
20 … 30 V DC
Outputs (elektronic)
Inputs (elektronic)
4
4
3
ID-Code
ID1-Code
ID2-Code
-
4
500 mA per output from 24 V supply
Length of connector cables
IO-Code
4
-
Capacity
AS-i Profil
S-8.F.E
7
8
A
S-7.A.E
F
7 (fixed)
S-7.DF.E
S-7.A.7
7
A
F
F (default) 7 (default)
7
F (default)
E
via AS-i
Operating current
≤ 70 mA
Displays
LED red (Fault)
LED on: voltage at the AS-i clamp
LED flashing: error, e.g. slave on adress 0
(default setting) or peripheral fault
Programming:
adress preset0
changeable via bus master or programming
devices
LED on: 24 V available
LED off: absence 24 V
EMC directions
EN 61 000-6-2
EN 61 000-6-4
Operating temperature
-25°C … +70°C
Storage temperature
-40°C … +70°C
Protection category
EN 60 529
IP54
+24V
+24V
ASIASI+
0V_ext_in
+24V_ ext_in
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Allowable shock and vibration
stress
Dimensions (L / B / H in mm)
Parameter bit
Bit Function
P0 0 = Off/1 = On (watchdog)
P1 0 = On/1 = Off (data input filter 128 µs)
P2 0 = On/1 = Off (synchronous I/O mode)
P3 not used
LED on:AS-i communication error
LED flashing: AS-i peripheral fault, e.g. no 24 V
or short circuit at an output, fuse
LED green (AUX)
Housing
Data bit
(Input via AS-i)
Bit Function
D0 Input I1/Output O1
D1 Input I2/Output O2
D2 Input I3/Output O3
D3 Input I4/Output O4
I/O: max. 15 m
S-7.A.7
Operating voltage
LED green (AS-i)
Programming
(Bit setting)
Abox 040
Abox 025
or 040
Abox 040
68 / 70 / 30
Abox 040
0V_ext_out
0V_ext_out
0V_ext_out
0V_ext_out
+24V
+24V
I4
I3
ASIASI+
0V_ext_in
+24V_ ext_in
O4
O3
O2
O1
I2
I1
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 145
Other Fieldbuses/
Master Simulators
Housing with external fastening tabs
AS-i Safety
Single Slave (up to 31 slaves) or
AB Slave (up to 62 slaves)
Price Lists
AS-i Specification 3.0
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i I/O Modules
AS-i MP Bus Gateway
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 Single Slave, MP Bus Master
For controlling up to 8 MP Bus participants
(e.g. Belimo)
Integrated power supply with overtemperature protection
Address socket
4 indicator LEDs
Article no. BW2406: for controlling up to 8 MP Bus participants
The AS-i Bus MP Gateway is used to control MP Bus slaves via
AS-i. The gateway represents for AS-i a slave, for the MP Bus a
Master.
It can be connected 4 MP bus segments, a total of up to 8
participants controlled.
Through the gateway can max. 8 bytes of input data and max. 8
bytes of output data via the AS-i bus resp. the overlaying control
processed.
Article no.
Connections
Power supply and drives
AS-i
MP Bus Terminal
Properties
Baudrate
Power supply primary side
Power supply secondary side
Input current max.
(fuse)
Output current max.
(fuse)
Overtemperature protection
Displays
LED green (AS-i)
LED green (MP-Bus)
LED green (UAUX)
LED red (FAULT)
Standards
EMC
AS-i profil
Housing
Operating temperature
Storage temperature
Protection category
Housing
Dimensions (L / B / H in mm)
BW2406
spring terminals
spring terminals
RJ-11
1,2 kBaud
230 V AC
24 V AC / 50 VA
0,5A
2A
The integrated, secure power supply ensures for the MP 24 VAC
of the bus participants (alternatively: connection 24 V DC or AC
possible).
About 4 rotatable external fastening tabs (or the 4 standard
casing bores), the housing can be mounted at also hard to reach
areas. The electrical connection is made via spring terminals.
Function LEDs indicate the operating state. An RJ-11 interface
allows the connection of an MP Bus terminal for addressing.
Programming:
(Bit setting)
Data bit (Input via AS-i)
Bit
D0
D1
D2
D3
Function
Input: valid telegram
Input:Timeout or another error message
Input: AUX voltage o.k.
Address programming device connected
Programming:
address preset0
changeable via bus master or
programming devices
130°C
voltage at the AS-i clamps
MP Bus connected
supply voltage 24 V (DC/AC) on
LED on: AS-i communication error
LED flashing: peripheral fault
EN 61 000-6-2
EN 61 000-6-4
S-7.4.0
-10°C ... +50°C
-15°C ... +80°C
IP54
plastic
180 / 130 / 75
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP54
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 146
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Diagnostics/Commissioning
Device
AS-i Analyser InnovationStep 2
AS-i Address Programming Device
BW1415
Characteristic
P.
complementation of local AS-i Master diagnostic
148
149
BW1191
with plug-in recharger 230 V
BW1646
with plug-in recharger 115 V (Version North America)
BW1935
AS-i addressing cable - infrared addressing adapter
BW1802
connecting cable (Module/programming device)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Accessories for
AS-i Address Programming Device
Art. no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview Diagnostics/Commissioning
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 147
AS-i Analyser Innovation Step 2
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Analyser Innovation Step 2
Complementation of local AS-i Master diagnostics
Diagnose and analysis tool for AS-i
For service or release of AS-i networks
Printing test protocols of AS-i networks
Article no. BW1415
The AS-i Analyser is a perfect complement to the local AS-i Master diagnostic of Bihl+Wiedemann.
Its functions:
• Statistics mode: statistical analysis of all telegrams transferred
in the network: it instantly gives the "traffic lights presentation"
of each slave's ability to communicate and provides a protocol
of the actual state of the network.
• Data mode: topical digital and analogue I/O-values and the
state of safety slaves.
• Trace mode: registers the complete telegram traffic and
examines it on a notebook.
• You can use the analyser in four different situations:
• when searching for errors,
• to provide a protocol which contains the network and its quality,
• to diagnose a network in detail, e. g. for preventive maintenance,
• to analyse your application e. g. of a Safety at Work network
The AS-i Analyzer is shipped in a fitted service case together with
a D-Sub data cable, an RS 232-USB adapter and the appropriate
screwdriver.
Requirements:
IBM compatible PC, 80486 or higher
Article no.
BW1415
Type
passive AS-i member
Interface
- AS-i
- RS 232 for connection to a PC
- Trigger input (24 V)
- Trigger output (TTL)
Operating system:
Windows 98, Windows Me, Windows 2000,
Windows XP and Windows NT4, Windows Vista
Voltage of insulation
≥ 500 V
Scope of delivery:
• Software:
AS-i Analyser
• Hardware:
AS-i Analyser
D-sub-transmission cord
RS232-USB adapter
Screwdriver
Service case with foam insert
LED display
LED green (Power)
power on
LED yellow (ser active)
RS 232 interface in operation
LED green/red (Test)
test mode
Telegram memory
256.000 AS-i telegrams
Operating current
approx. 70 mA out of AS-i
Operating Voltage
≥ 20 V
EMC directions
according EN 50 081-2,
EN 61 000-6-2
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +70°C
AS-i specification
2.1
Accessories (optional):
AS-i Tuner (Article no. BWU1648, see page 154)
AS-i Bus Termination (Article no. BWU1644, see
page 154)
More information can be found online at www.bihl-wiedemann.comInnovation Step 2 of the AS-Interface Analyser: New functions and
new possibilities
Price Lists
AS-i Safety
Its benefits:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 148
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Address Programming Device
Addressing/programming max. 62 slaves
Display of all the slaves in the bus
Reading and writing slave data
Addressing of AS-i modules with an optical data interface
BW1935
• AS-i addressing cable
for addressing of active AS-i modules
with infrared addressing interface (BW1935)
• Connecting cable
module/programming device (BW1802)
BW1802
BW1191, BW1646
Article no. BW1191: AS-i address programming device with plug-in recharger 230 V
Article no. BW1646: AS-i address programming device with plug-in recharger 115 V (North America)
Article no. BW1935: AS-i addressing cable - infrared addressing adapter
Article no. BW1802: Connecting cable (Module/programming device)
The AS-i address programming device is a compact device for
addressing AS-i slaves such as sensors, actuators and coupling
modules. The AS-i address programming device uses a universal
adapter to connect to other devices. The AS-i address programming device can be used for AS-i slaves according to the AS-i
specification 2.0, 2.1 and 3.0.
gramming device and an AS-i module. In this case the
TTL-signals of the addressing-device are converted into optical
signals and vice versa for the AS-i module. The AS-i addressing
cable is connected via the M12 plug connector at the AS-i address programming device and via the infrared-head at the AS-i
module.
The AS-i addressing cable (BW1935) is the necessary accessory for the signal transmission between the AS-i address pro-
The connecting cable (module/programming
(BW1802) is used for the addressing of AS-i slaves.
BW1191
BW1646
Application
Commissioning and diagnosis
Indication
LCD, character size is 13 mm
Buttons
Interface/connection
Cable length
Supply
Recharger
BW1935
BW1802
Addressing of AS-i modules
keypad, 5 keys
-
AS-i, short circuit
and overload protected
–
Addressing of AS-i modules
-
–
infrared head/M12 connector
round connector 2-pin/
M12 connector
1m
1,6 m
battery (built-in)
-
plug-in recharger (supplied)
-
230 V AC
115 V AC
-
Charging time
ca. 12 h
-
Operating time
8 h ≥ 250 read/write operations
with a fully charged battery
-
Protection category (EN 60 529)
IP20
Operating temperature
0 °C … +50 °C
Storage temperature
Weight
Other Fieldbuses/
Master Simulators
Article no.
device)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Accessories for AS-i Address Programming Device:
-20 °C … +55 °C
approx. 550 g
-
AS-i Safety
•
•
•
•
AS-i-Master/Gateways/
Links/Scanner
AS-i Address Programming Device
Addressing references (Infrared addressing adapter BW1935):
• The power supply must be on during addressing.
• Plug the M12 connector of the IR interface adapter to the relevant connection of the AS-i address programming device.
• Plug the the infrared head of the IR interface adapter onto the AS-i module. Ensure that it is fixed properly to the coding element.
Caution:
• Only the supplied battery recharger may be used for the reloading of the batteries of the AS-i address programming device.
Please pay attention to the land version!
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 149
Price Lists
• Perform addressing as outlined in the description for the AS-i address programming device.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 150
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Repeater/Tuner/Bus Termination
Device
Art. No.
Characteristic
P.
AS-i Diagnostic Tuner
BWU1843
with AS-i slave address
trebling of AS-i cable length
AS-i Tuner
BWU1648
without AS-i slave address
trebling of AS-i cable length
AS-i Bus Termination
BWU1644
default value of the AS-i Tuner
doubling of AS-i cable length
Advanced Repeater with
Bus Termination
BWU2192
circuit extension by more than 200 m,
passive bus termination connectable
156
Advanced Repeater
BWU1855
circuit extension by more than 100 m
157
BWU1273
extends network an additional 100 m,
protection category IP65
158
BW2384
Higher transmission and reception levels to High Power 159
Segment A, protection category IP20
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i High Power Repeater
154
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Repeater/Tuner/Bus Termination
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 151
Circuit Extension
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Circuit Extension
Circuit Extension by Repeater
Today's standard for networks over 100 m is to supplement one or
several repeaters and as many power supplies (configuration B1).
The passive bus termination permits an extension of up to ca.
200 m. However, Bihl+Wiedemann recommends to carefully
check the number of repeated telegrams in each installed network (use the error counter in B+W masters or a B+W analyser).
If the compensation of the network's impedance is successful,
this configuration is the most cost-effective one for an extension
(config. D1).
Config. B1: Conventional solution using repeaters and
additional power supplies to realise networks with more than
100 m
One alternative is the IP20 repeater that is in a service cabinet together with the power supply. The main advantage is the easy
mounting of the repeater in the cabinet (configuration B2). The
IP20 repeater has been designed with this intention.
Config. B2: Simplifying the mounting by using the IP20 repeater
inside the service cabinet.
Config. D1: The passive bus termination permits networks up to
ca. 200 m (check the repetition rate, please).
In networks of up to ca. 300 m, it is more secure and feasible to
use the Bihl+Wiedemann tuner. This is an active bus termination
which adjusts itself automatically to the situation found in the particular network. Thus it reaches farther and works in more conceivable configurations (configuration D2).
Additional benefit: The tuner shows continuously whether compensation has been reached well enough. Three LEDs (green,
yellow, red) signal "normal communication", "functioning but with
a remarkable amount of repetitions", or "too many repetitions or
(sporadic) loss of at least one slave". As opposed to a fixed bus
termination, the alignment of the tuner can easily be repeated at
any time if the plant is changed.
AS-i Safety
Other Fieldbuses/
Master Simulators
Optimizing the Energy Distribution with Repeaters
Repeaters may also be used to isolate parts of a network from
each other or to feed several segments of a network by separate
power (configuration C1).
Config. D2: The active bus termination by a tuner permits
networks up to ca. 300 m. In addition it checks and signals
communication quality.
Config. C1: Separation of 1 network into 3 galvanically isolated
segments, e.g. to feed a network that demands 12 A by 3
separate power supplies.
For even bigger networks, tuners or bus terminations and repeaters can be combined. As up to two repeaters may be used in series, one can achieve lengths of up to 600 m (with passive bus
termination) or 900 m (with tuners), respectively. This is shown in
configuration D3 with two segments.
Circuit Extension by Bus Termination Plug or by Tuner
Price Lists
If a network of more than 100 m is needed, the answer is no longer "add a repeater and a power supply (for each 100 m)" (configuration B1). Bihl+Wiedemann now offers two more intelligent
solutions: The (passive) bus termination and the (active) tuner,
both with a protection degree of IP65.
Config. D3: 600 m-network with tuner plus repeater. May be
extended up to 900 m.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 152
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Tuning of AS-i Networks
at Work), optimising the impedance of the individual network may
be advantegeous.
New possibilities with the Advanced Repeater
Bihl+Wiedemann GmbH expands into new dimensions with innovations: AS-i networks with 1 to 1,5 km line length can be created
with the help of the new Advanced AS-i, the Bus Termination (or
the AS-i Tuner). Two new Advanced AS-i-Repeater can be also
operated in a row in combination with the Bus Termination (or the
AS-i Tuner).
The optional AS-i 3.0 Slave inside the Diagnostic Tuner supervises the AS-i voltage as a 16 bit value and monitors the quality of
the AS-i communication permanently. In case of problems the Diagnsotic Tuner informs the AS-i Master.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Please note: There is no decrease in date security when using
the AS-i tuner. The high level measures of data security and error
detection are NOT affected. Thus the tuner may also be used in
Safety at Work networks.
Apart from extension the tuner can even be used to correct an unstable network if the instability is caused by a faulty impedance.
Thus networks can be run properly and with a high degree of
availability even if their components misfit the specifications to
some extent. This effect is due to the active adjustment and the
continuous monitoring by the tuner. Especially if a network has to
be extremely reliable (e.g. in plant automation or with AS-i Safety
AS-i-Master/Gateways/
Links/Scanner
Circuit Extension
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Config. D4: 1000 m AS-i line with mit Advanced Repeaters and Bus Terminations in a row.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 153
AS-i Tuner, AS-i Bus Termination
AS-i Master/Gateways/
Links/Scanner
AS-i Tuner:
Triplication of the AS-i cable length
Strengthen of the robustness of AS-i
Supervise the quality of the installation
Tool for the service
AS-i Bus Termination:
AS-i-Bus Termination
(Default value of the AS-i Tuner)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Doubling of the AS-i cable length
(Default value of the AS-i Tuner)
Article no.: BWU1843: AS-i Diagnostic Tuner (with AS-i Slave address)
Article no.: BWU1648: AS-i Tuner (without AS-i Slave address)
Article no.: BWU1644: AS-i Bus Termination (Default value of the AS-i Tuner)
The AS-i Diagnostic Tuner is suitable for the employment as diagnose unit, which announces the bus function of the control online. Unlike to the AS-i Tuner the AS-i Diagnostic Tuner is able to
read in the traffic light announcements for each individual slave
and to refer to the superordinate control system.
Article No.
Connection
LED green
LED red
The AS-i Diagnostic Tuner can be switched off over a switch completely or set on a default value.
BWU1648/BWU1843
BWU1644
AS-i flat cable/AS-i round cable
Operating value
LEDs
Other Fieldbuses/
Master Simulators
The result can be intergrated into an application program. It signals whether an optimization succeeded. Gradual changing of
the quality of the AS-i circuit can be recognized and repaired so
on time.
The primary task of the AS-i Tuner consists in the length adjustment in AS-i circuits without repeater.
Operating current
AS-i (30 V DC)
60 mA
10 mA
5
2
LED (AS-i Power) on:
U AS-i > 26 V
LED (AS-i Power) flashing:
18,5 V < U AS-i < 26 V
U AS-i > 26 V
Error (AS-i Analyser)
-
LED yellow
Warning (AS-i Analyser)
U AS-i > 18,5 V
LED green
Communcation o.k.
(AS-i Analyser)
-
Ambient operating temperature
EMC
Dimensions (L / B / H in mm)
Bit Allocation
In 0, In 1
binary bits, freely usable
In 2, In 3
serial communication
Out 0, Out 1 serial communication
Out 2
binary bits, freely usable
-25 … +75 °C
Protection category according to
EN 60 529
Electromagnetic sust.
Slave Profile (BWU1843)
I/O Code:
0x7
ID Code:
0xA
ID1 Code:
0x0
ID2 Code:
0x5
VENDOR ID: 0x0002
PRODUCT ID: 0x0002
AB-Slave (up to 62 Slaves)
0 … +55 °C
Storage temperature
IP65
according to slave spezification
EN 61 000-6-2, EN 61 000-6-3
90 / 80 / 43
46 / 19
The passive bus termination permits a circuit extension up to approximately 200 m
Price Lists
AS-i Safety
AS-i Tuner
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 154
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Tuner, AS-i Bus Termination
In0, In1
The LEDs indicate the result of the optimization:
Bit
LED
Description
11
red
serious disturbances
10
yellow
01
green
00
---
Combi Slave Profile
So that data transmission rates of approx. 50 Baud are attainable
in the AS-i A/B operation. Because of the ID code "A" is the Diagnostic Tuner a slave with an extended address range and takes
in the A/B operation one of 62 addresses, in the standard mode
as A-slave one of 31.
Out2
A change of 0 to 1 has the same effect as a depressing the key.
However no training procedure is released. It can be released
only by means of parameters.
Parameter
The parameter bits release (independently of the position of the
rotary switch) a training procedure. Only the parameter 5, then
the parameter 2 within 5 seconds causes the start of a training
procedure.
Analog Channel 0
Tension
as 16 bit value of 0 ... 32 767 in mV
Resolution
10 bit
Analog Channel 1
Tension
as 16 bit value of 0 ... 32 767 in mV
AS-i 3.0 Specification
Resolution
10 bit
Since the Diagnostic Tuner uses the extended functions as slave,
he must be used together with a master after the AS i 3.0 specification. The primary tuner functions is available however also
with a AS-i Master according to the specification 2.0 or 2.1.
Vendor Specific Object 1
This object contains a pair of bits, which shows the condition of
the slaves in this address for all 62 possible slaves:
Bit
LED
11
red
10
yellow
01
green
00
no slave
Byte
27
26
25
24
23
22
21
20
1
3/3A
3/3A
2/2A
2/2A
1/1A
1/1A
---
---
2
7/7A
7/7A
6/6A
6/6A
5/5A
5/5A
4/4A
4/4A
29B
29B
28B
28B
...
16
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
2I/1O data for the basic function of the tuner are transmitted
thereby as usual, and are usable with each master. The serial
data – here the analog values of the tension and the traffic light
values of the individual slaves – are transmitted by the piece with
the remaining bits, built up in the master again and sent from here
than simple complete telegram to the control. The user finds the
up-to-date measured AS-i tension and the minimum AS-i tension
as 16 bit analog value in the field of the input data (similar to the
analog value transmission).
almost repetition-free communication
none result available („Tuning-Phase“, or the
push-button even pressed)
Other Fieldbuses/
Master Simulators
The AS-i Diagnostic Tuner operates after the new "combi slave
profile" S-7.A.5, in which digital and serial data will be parallel
transferred.
more frequent replications, which should be
clarified depending upon application
AS-i-Master/Gateways/
Links/Scanner
Description of the Bit Allocation
...
31B
31B
30B
30B
Price Lists
Accessories:
• AS-i Analyser (art. no. BW1415, see also page 148)
• AS-i passive distributor H (art. no. BW1239, see also page 182)
AS-i Safety
The Bihl+Wiedemann tuner permit a stable communication with
net lengths to approximately 300 m without the employment of a
Repeater and without a second power supply unit.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 155
AS-i Repeater IP20
AS-i Master/Gateways/
Links/Scanner
Circuit extension up to 200 m
On-Board diagnostics AS-i Fault and AS-i Power
Passive bus termination connectable for segment A
AS-i voltage metering segment A
Galvanic isolation
Requires no programming
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Passive on the AS-i network
(no slave adress required)
Article no. BWU2192 Advanced Repeater with bus termination in IP20
Beside the power supply, the AS-i Repeater with On-Board-Diagnostics displays separately AS-i communication errors. The red
AS-i Fault LED flashes as long as there is no AS-i communication. The communication error LED will help the customer to find
basic installation problems really fast. The new AS-i Repeaters in
IP 20 are compatible with all existing AS-i Repeaters and can
easily be mounted into the switchboard in combination with an
AS-i power supply. The passive bus termination allows a circuit
extension up to 200 m.
Article no.
BWU2192
Connections:
Connections
COMBICON clamps
1
AS-i A-
AS-i voltage
26,5 ... 31,6 V via AS-i
2
AS-i A+
Max. AS-i current consumption
60 mA (network segment), 120 mA (total)
3
AS-i A-
Quantity of required AS-i power supplies 1 additionally (as any AS-i-Repeater)
Other Fieldbuses/
Master Simulators
Voltage of insulation
Display
4
AS-i A+
5
n.c.
+
U> U>
26V 18,5V
… …
TERM
12 n.c.
FAULT AS-i Seg.B (red)
AS-i communication error network B
13 AS-i B+
PWR AS-i Seg.A (green)
AS-i power network A
14 AS-i B-
PWR
FAULT AS-i Seg.A (red)
AS-i communication error network A
15 AS-i B+
AS-i Seg. B
TERM (yellow)
Bus termination network A enabled
16 AS-i B-
U AS-i segment A > 26 V
U > 18,5 V (yellow)
U AS-i segment A > 18,5 V
Applied standards
EN 61 000-6-2, EN 61 000-6-3
FAULT
-25 … +75 °C
Protection category EN 60529
IP20
Electromagnetic sustainability
according to slave specification
Dimensions (L / W / H in mm)
114 / 22,5 / 99
FAULT
PWR
AS-i Seg. A
AS-i Segment B
0 … +55 °C
Storage temperature
+
TERM
Seg. A
OFF
AS-i power network B
U > 26 V (green)
–
AS-i Segment A
PWR AS-i Seg.B (green)
Operating temperature
AS-i Safety
≥ 500 V
–
+
–
+
–
Note:
Price Lists
• The AS-i Repeater does not occupy any slave address. The total amount of the slaves (31 resp. 62) per AS-i network remains constant. No programming required.
Accessories:
•
•
•
•
•
AS-i Power Supply (art. no. BW1649, see also page 166)
AS-i Bus Termination (art. no. BW1644, see also page 154)
AS-i Tuner (art. no. BW1648, see also page 154)
AS-i Repeater in IP65 (art. no. BW1273, see also page 158)
AS-i Analyser (art. no. BW1415, see also page 148)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 156
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Repeater IP20
AS-i-Master/Gateways/
Links/Scanner
Circuit Extension by more than 100 m
On-Board Diagnostics AS-i Fault
Galvanic isolation
No programming required
Passive on the AS-i network
(no slave address required)
Article no. BWU1855 Advanced Repeater (Circuit extension by more than 100 m)
The AS-i Repeater with On-Board Diagnostics has got a LED for
power supply and AS-i communication errors. The red AS-i Fault
LED flashes as long as there is no AS-i communication. The communication error LED will help the customer to find basic installation problems really fast.
Especially the AS-i Repeaters in IP20 can be easily mounted into
the switchboard in combination with an AS-i power supply.
Together with the AS-i Tuner and the AS-i Bus Termination, the
AS-i Repeater from Bihl+Wiedemann is a perfect package for
every AS-i network.
The new AS-i Repeaters are compatible with all existing AS-i Repeaters.
Artikel no.
BWU1855
Connections
Combicon claps
Operating voltage
via AS-i
Operation current
60 mA (per network segment), 120 mA (total)
Quantity of required AS-i power supplies
1 additionally (as any AS-i Repeater)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Simple mounting next to the AS-i power supply
PWR1
AS-i power network 1
FAULT1
AS-i communication error network 1
PWR2
AS-i power network 2
FAULT2
AS-i communication error network 2
Ambient operating temperatur
Storage temperature
0 … +55 °C
-25 … +75 °C
Other Fieldbuses/
Master Simulators
4 LEDs
Protection category according to EN 60 529 IP20
Voltage of insulation
≥ 500 V
EMC
according to EN 61 000-6-3, EN 61 000-6-2
Dimensions (L / B / H in mm)
105 / 22,5 /114
Connections: BWU1855
1
AS-i-2
2
AS-i+2
3
AS-i-2
4
AS-i+2
5
n.c.
… …
20 n.c.
21 AS-i+1
Accessoires:
• AS-i power supply (art. no. BW1649, see also page 166)
• AS-i bus termniation (art. no. BW1644, see also page 154)
• AS-i Tuner (art. no. BW1648, see also page 154)
• AS-i Repeater in IP65 (art. no. BW1273, see also page 158)
• AS-i Analyser (art. no. BW1415, see also page 148)
AS-i Safety
according to slave specification
Note:
The AS-i Repeater does not occupy any slave address. The total amount of the slaves
(31 respectively 62) per AS-i network remains constant. No programming required.
22 AS-i-1
23 AS-i+1
24 AS-i-1
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 157
Price Lists
Electromagnetic sustainability
Repeater IP65
AS-i Master/Gateways/
Links/Scanner
Advanced Repeater from Ident. no. 12243
Extends networks an additional 100 m and allows networks of more
than 1 km in combination with the AS-i Tuner or AS-i Bus Termination
Several advanced AS-i Repeaters can be operated in parallel
On-Board Diagnostics: displays power supply and
AS-i communication errors separately
Requires no programming
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Passive on the AS-i network
(no slave address required)
Article no. BWU1273: AS-i Advanced Repeater IP65
Beside the power supply, the AS-i Repeater with On-Board-Diagnostics displays separately AS-i communication errors.
sion up to 1 km is possible. Furthermore it is permitted to use several parallel operating Advanced Repeaters.
With the help of the advanced AS-i Repeaters (from Ident. no.
12243) two repeaters can be operated in combination with the
AS-i Tuner or AS-i Bus Termination in a row. Thus, circuit exten-
The AS-i Repeaters are compatible with all existing AS-i Repeaters.
.
Article no
Connections
BWU1273
AS-i flat cable / AS-i round cable
Operating voltage
via AS-i
Operating current
60 mA (per network segment), 120 mA (total)
Qunatity of needed power supplies
2
Other Fieldbuses/
Master Simulators
4 LEDs
U AS-i1
AS-i power network 1
FLT1
AS-i communication error network 1
FLT2
AS-i communication error network 2
U AS-i2
AS-i power network 2
Ambient operating temeprature
-10 … +55 °C
Storage temperature
-25 … +75 °C
Protection category according to EN 60 529
IP 65
Electromagnetic Sustainability
according to slave specification
Voltage of insulation
≥ 500 V
EMC
according to EN 61 000-6-3, EN 61 000-6-2
Note: The AS-i Repeater needs no slave address. The total amount of the slaves (31 respectively 62) per AS-i network remains the
same. No programming required.
Price Lists
AS-i Safety
LEDs
1
U AS-i1
2
FLT1
3
free
4
FLT2
5
U AS-i2
Accessories: AS-i substructure module to connect 1 AS-i round cable, 1 round cable or additional supply (Art. no. BW1183, see
page 183) by using of AS-i round cables
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 158
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i High Power Repeater in IP20
AS-i-Master/Gateways/
Links/Scanner
AS-i High Power Repeater for sliding contacts
Higher transmission and reception levels to High Power Segment A
To interference insensitive point-to-point connections
On-Board Diagnostics AS-i Fault and AS-i Power
Galvanic isolation
Article No. BW2384 AS-i High Power Repeater for sliding contacts in IP20
interference resistance, for example, to parallel supply lines of
converters is highly improved due to higher transmission and reception levels.
BW2384
Connections:
Connections
COMBICON clamps
1
High Power A-
AS-i voltage
26,5 ... 31,6 V via AS-i
2
High Power A+
Max. AS-i current consumption
60 mA in Segment B, 180 mA in Segment A,
3
High Power A-
240 mA (total)
4
High Power A+
Quantity of required AS-i power
supplies
1 aditionally (as any AS-i Repeater)
5
n.c.
Voltage of insulation
≥ 500 V
Display
… …
12 n.c.
PWR AS-i Seg.B (green)
Power AS-i Segmnt B
13 AS-i B+
FAULT AS-i Seg.B (red)
Communication error Segment B
14 AS-i B-
PWR High Power Seg.A (green)
Power High Power Segment A
15 AS-i B+
FAULT High Power Seg.A (red)
Communication error High Power Segment A
16 AS-i B-
TERM (yellow)
Bus termination High Power Segment A enabled
U > 26 V (green)
U High Power Segment A > 26 V
U > 18,5 V (yellow)
U High Power Segment A > 18,5 V
Applied standards
EN 61 000-6-2
EN 61 000-6-3
Ambient operating temperature
–
+
–
+
High Power Segment A
TERM
Seg. A
OFF
U> U>
26V 18,5V
TERM
FAULT
FAULT
PWR
PWR
AS-i Seg. B
High Power
Seg. A
AS-i Segment B
+
–
+
–
0 … +55 °C
Storage temperature
-25 … +75 °C
Protection category acc. EN 60 529
IP20
Electromagnetic sustainability
according to slave specification
Dimensions (L / W / H in mm)
114 / 22,5 / 99
Hint:
Air circulation in the power supply may not be
disturbed: therefore when mounting see that is
at least 50 mm free space down/above and
30 mm free space left/right!
AS-i Safety
Article No.
Other Fieldbuses/
Master Simulators
The AS-i High Power Repeater for sliding contacts works with 3 x
higher transmission and reception levels. The AS-i communication for sliding contacts gets considerably less sensitive to disturbances. AS-i is basically very inured to disturbances. The
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Passive on the AS-i network (no slave address required)
Accessories:
• AS-i Power supply (art. no. BW1649, see also page 166)
• AS-i Bus termination (art. no. BWU1644, see also page 154)
• AS-i Tuner (art. no. BWU1648, see also page 154)
• AS-i Repeater in IP65 (art. no. BWU1273, see also page 158)
• AS-i Analyser (art. no. BW1415, see also page 148)
• AS-i Module for Power Decoupling (art. no BW2387, see also page 176)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 159
Price Lists
Note:
The AS-i High Power Repeater does not occupy any slave address. The total amount of the slaves
(31 respectively 62) per AS-i network remains constant. No programming required.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 160
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Power Supplies
AS-i Power Supply 1,8 A
BW2255
AS-i Installation Power supply from 115 VAC up to
250 VAC
164
AS-i Power Supply, 4 A/8 A
BW1649
90 V AC up to 265 V AC, wide range supply, 4 A
166
BW1997
115 V AC/230 V AC, with range switch, 8 A
BW2276
8 A AS-i power supply with integrated filter for input
voltage from 195 Vac up to 500 Vac
167
24 V to 30 V AS-i Power Supply BW1760
in Stainless Steel, 2 A
24 V DC to 30 V AS-i output voltage
169
Power Supply for AS-i Master
in Stainless Steel,4 A/8 A
BW1593
Power Supply, 8 A
170
BW1598
Power Supply, 8 A, Class 1 Div 2
BW1597
Power Supply, 4 A, Class 1 Div 2
BW1927
Power Supply, 4 A, for 2 AS-i circuits
172
BW1676
Power Supply, 8 A, for 2 AS-i circuits
173
AS-i Wide Range Power Supply
8A
Characteristics
P.
Price Lists
Power Supply, 4 A/8 A, with
3 phases for AS-i Master in
Stainless Steel
UL
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art. No.
Other Fieldbuses/
Master Simulators
Module
AS-i Safety
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview Power Supplies
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 161
Power Supplies
Module
Art. No.
AS-i Power Supply Decoupling
Unit: supply of 2 AS-i networks
out of 1 power supply
BWU1943
applicable with double masters without integrated data
decoupling
AS-i Power Extender
BW1197
extends the distance between AS-i power supply and AS-i 175
network, 2,8 A
BW1713
extends the distance between AS-i power supply and AS-i
network, 2,8 A, Class 1 Div 2
BW1477
extends the distance between AS-i power supply and AS-i
network, 4,0 A
BW1714
extends the distance between AS-i power supply and AS-i
network, 4,0 A, Class 1 Div 2
BW2387
in combination with an AS-i Repeater:
176
decouples 1,2 A from AS-i Segment B and supplies
Segment A with 1,2 A
AS-i Module for Power
Decoupling
UL
Characteristics
P.
174
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Housing
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 162
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Power Supplies
AS-i-Master/Gateways/
Links/Scanner
AS-i Power Supplies
Nowadays, AS-i networks are the standard technology for
applications with up to 62 participants and a length of up to 100 m
(configuration A1). Their benefits are low costs, simple
installation and a reliable operation. For the single network
configuration, Bihl+Wiedemann offers different masters,
gateways and links in IP20 und IP65 including some useful
application functions, as well as a power supply (4 A) and a
diversity of analogue slaves.
Config. A4: The second step: Using a double master in the version "1
power supply, 1 gateway for 2 AS-i networks".
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
If more than 62 slaves, cables longer than 100 m, more flexibility,
or more flexibility in the network are needed, formally the answer
to these cases was "duplicate all". The standard AS-i single
network with up to 62 slaves and 100 m in length used to be the
biggest unit (configuration A2). The rest was a matter of
multiplying.
Config. A2:
network.
Multiple networks simply duplicating the standard single
Using 1 power supply for several double masters.
The identical power supplies can be used together with external
data decoupling units of an "AS-i Power Extender" to feed several
separate networks. As the leads between the power supplies and
the data decoupling do not count in the 100 m-limit, these
networks may be placed separately from each other
(configuration A6).
If IP65-masters are used no service cabinets are required. The
power supply may be placed in a central switch box (but mind the
voltage drop!). This configuration is of special interest in large
and spacious applications.
AS-i Safety
Today there are several alternatives. A first step to more
intelligent solutions is to install a double master, which is more
cost effective than two single masters and saves one connection
with a higher system (configuration A3). Thus the (cost) threshold
to use multiple networks is lowered. Not only the number of
slaves can require a second network, but also the higher rate of
flexibility in designing a plant may make them appear desirable.
Config. A5:
Other Fieldbuses/
Master Simulators
Config. A1: The standard: single network, often with coupling to a
higher level network, e.g. to PROFIBUS.
Several double masters can even be supplied from only one
power supply.
Config. A3:
Two networks are served by one double master.
Config. A6: External data decoupling (AS-i power extenders) can be
used to feed several masters from 1 power supply
(BW1592/BW1593/BW1676).
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 163
Price Lists
As the second step Bihl+Wiedemann offers now also a double
master, which gets by only one power supply unit (configuration
A4); the data decoupling is integrated inside the master (up to 4 A
for each AS-i circuit), the power supply (30 V / 4 A or 8 A).
AS-i Power Supply 1,8 A
AS-i Master/Gateways/
Links/Scanner
AS-i Power Supply 1,8 A
AS-i Installation Power supply from 115 VAC up to 250 VAC
Primary switched-mode regulator 31,2 V/1,8 A
LED operation indicator
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW2255 AS-i Power Supply 1,8 A
The power supply is continous idle running protected and thus
dellivers a variable direct current of 0 - 1,8 A as output current.
Temperature indication and curve is based on the ambient temperatures from -5°C up to 40°C specified by the AS-i norm. However, the power supply is operating until an ambient temperature
Article no
of approx. 60°C with nominal load. With higher temperatures the
output voltage, that is the total power is adjusted and so the
power supply is protected from destruction.
When temperature falls below 60°C, the power supply will again
work in normal operation mode.
BW2255
Input
Nominal input voltage
100 - 240 VAC, 47 - 63 Hz
Input voltage
94 - 265 VAC
Nominal input current
0,65 A at 230 VAC; 1,0 A bei 115 VAC
Peak inrush current
I²t < 1,5 A²s
Power factor cos ϕ
0,4 capacitive at 230 VAC; 0,55 capacitive at 115 VAC
Applicable wire size of input clamps
0,5 ... 2,5 mm² (AWG20 ... AWG13)
Tightening torque of the input clamps
0,6 - 0,8 Nm
Insulation stripping lentgh
10 mm
Output
Other Fieldbuses/
Master Simulators
Output voltage Uout
31,2V ± 3%
Output current Iout
0 - 1,8 A
Ripple
< 50 mVpp (0 ... 10 kHz); < 10 mVpp (35 ... 500 kHz)
Current limitation typ.
2,3 A
Efficiency typ.
88%
Applicable wire size of output clamps
0,5 ... 2,5 mm² (AWG20 ... AWG13)
Tightening torque of the output clamps
0,6 - 0,8 Nm
Insulation stripping lentgh
10 mm
Regulation
Line regulation
< 0,2% at Uin = 230 VAC ± 15%
→ 1,8 A
↔ 90% (Iout max), peaks < 2%
Load regulation
< 0,5% at 0 A
Dynamics
< 2 ms at 10
AS-i Safety
Protection and monitoring
Internal fuse
T2,5 A / 250 V TR5 IEC 60 127-3/IV
Current limitation
Protected against continuous short circuit (see diagram)
Overload protection
yes
Idle running protection
yes
Hold-up time
Safety
> 65 ms bei Uin = 230 VAC; > 10 ms bei Uin = 115 VAC
VDE 0805/EN 60 950/IEC 950
Output
Safety extra low voltage SELV
Protective system (EN 60 529)
Class II
IP20
< 0,25 mA (47 - 63 Hz line frequency)
Price Lists
Protection category
Leakage current
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 164
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Power Supply 1,8 A
EN 55 011, EN 50 082-1, EN 61 000-6-2
RFI suppression
EN 55 022, EN 55 011 class B
Static discharge ESD ref. (IEC 61 000-4-2)
8 kV contact discharge, 15 kV free air discharge (EN 61 000-4-2)
Electromagnetic fields ref. (IEC 61 000-4-3)
10 V/m (EN 61 000-4-3)
Burst ref.( IEC 61 000-4-4)
4 kV input, 2kV output/capacitive coupling clamp (EN 61 000-4-4)
Surge ref. (IEC 61 000-4-5)
4 kV unsymmetrical (EN 61 000-4-5)
Conducted disturbances ref. (IEC 61 000-4-6) 10V, 150 kHz ... 80 MHz (EN 61 000-4-6)
AS-i Certification
AS-i Certification
Pending
Operational data
Temperature range
-10°C ... +40°C, by free convection (start from -25°C)
Power derating
2,5% / K from +40°C (see diagram)
Storage temperature
-25°C ... +85°C
AS-i-Master/Gateways/
Links/Scanner
EMV CE-certified
Displays
The green LED indicates normal operation (0 A ... 1,8 A)
Mounting position
vertikal as shown in figure
Input terminals
upper side
Output terminals
lower side
Assembly
Plastic slider for fastening to mounting rails DIN EN 50 022-35
Mechanics
Dimensions max. (W / H / D):
45 / 72 / 105
Weight
approx. 0,2 kg
Derating
Current limitation curve
Output voltage
Output power
100%
100%
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
LED green
Mounting
Automatic restart
hicc-up mode
25%
4 0 °C
7 0 °C
Ambient temperature
Dimensions (size in mm)
Price Lists
AS-i Safety
Connections
100%
Output current
Other Fieldbuses/
Master Simulators
ca. 60%
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 165
AS-i Master/Gateways/
Links/Scanner
AS-i Power Supply 4 A/8 A
AS-i Power Supply 4 A
90 V AC up to 265 V AC wide range power supply (BW1649)
AS-i Power Supply 8 A
115 V AC/230 V AC power supply with range switch (BW1997)
SELV
LED operation indicator
AS-i data decoupling
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Power factor correction
BW1649
Article no. BW1649 AS-i Power Supply 4 A, wide range power supply
Article no. BW1997 AS-i Power Supply 8 A, power supply with range switch
The primary clocked power supply is supposed for fieldbus applications, which transport energy and data via a 2-wire line at the same
time.
Article no.
BW1649
BW1997
Power factor
Input frequency
N
47 … 63 Hz
90 … 265 V AC
L
115/230 V AC
BW1649
BW1997
230
approx. 90%
without idle current at 230 V AC
Input current Ie
approx. 0,6 A
Input fuse
approx. 1,2 A
LED Power
LED Overload
internal fuse
electronic fuse against external short circuits
Output
AS-i _
Output voltage
29,5 V … 31,6 V DC
AS-i +
Remaining ripple
according to AS-i Specifaction
Output current
4A
8A
approx. 4,5 A
approx. 8,5 A
Current limititation
LED green (PWR)
power on (at frontside)
LED red (Overload)
overload error (at frontside)
Standard conformity
Protection category (EN 60 529)
IP20
Standards
Ground
Hints:
• Clamp GND must be connected with
machine ground.
• Air circulation in the power supply may not be
disturbed: therefore when mounting see that
is at least 3 cm free space down and sufficiently free space above!
EN 60 950
UL 60 950
Ambient operating temperature
UL 60 950 intended,
AS-i certificate intended
-10°C … +55°C
Storage temperature
-40°C … +85°C
Dimensions (L / W / H in mm)
129 / 70 / 126
151 / 70 / 141
BW1997
126
141
BW1649
70
PE
approx. 0,6 (according to input voltage)
Displays
AS-i Safety
Connections:
Input
Efficiency
Other Fieldbuses/
Master Simulators
imately in phase with the voltage by means of the passive power factor correction and leads to only a little reactive power. This guarantees
a power factor cosϕ ≥ 0,6.
The AS-i Supply powers a fully loaded AS-i system with a maximum
Besides the energy supply the power supply takes over also the funcoutput current of 4.0 A or 8.0 A. The sinusoidal current consumption
tion of data decoupling to the power source and the balancing of the
of the power supply prevents harmonic waves. The current is approxtwo AS-i output lines in relation to the machine ground (shield).
Due to the accurate and transformic coupling the use of unscreened load lines is possible.
Voltage range Ue
Price Lists
BW1997
129
70
151
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 166
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Wide Range Power Supply 8 A
8 A AS-i power supply with integrated filter for input voltage
from 195 Vac up to 500 Vac
Primary switched-mode regulator 31,2 V/8 A
LED overload indicator
AS-i-Master/Gateways/
Links/Scanner
AS-i Wide Range Power Supply 8 A
LED operation indicator
Temperature indication and curve is based on the ambient temperatures from -5°C up to 40°C specified by the AS-i norm. However, the power supply is operating until an ambient temperature
When temperature falls below 60°C, the power supply will again
work in normal operation mode.
BW2276
Input
Nominal input voltage
230/400 VAC 47-63 Hz
Input voltage
195 - 500 VAC
Nominal input current
1 A bei 400 VAC
Peak inrush current
< 50 A
Power factor cos ϕ
0,7 capacitive at 400 VAC
PFC norm (harmonics)
EN 61 000-3-2 class A
Output
31,2V ± 1%
DC output current
0-8A
Ripple
< 60mVpp (10 ... 500 kHz)
Current limitation typical
8,5 A
Efficiency typical
88%
Regulation
Line regulation
< 0,2% at Uon = 400 VAC ± 15%
→8A
↔ 90% (Iout max), peaks < 2%
Load regulation
< 1% at 0 A
Dynamics
< 2 ms at 10
Protection and monitoring
Internal fuse
T3,15 A / 500 V 6,3 x 32 mm
Current limitation
protected against continuous short circuit (see diagramm) and idle running
Overload prot.
yes
Idle running prot.
yes
Hold-up time
Safety
> 15 ms at Uin = 230 VAC
VDE 0805/EN60950/IEC950
Output
safety extra low voltage SELV
Protective system (EN 60 529)
class I
Protection category
IP20
Leakage current
< 3,5 mA (47-63 Hz mains frequency)
EMV CE-certified
EN 55011, EN 50082-1, EN 61000-6-1, EN 61000-6-2
Harmonics
EN 61000-3-2 class A
RFI suppression
EN 55022, EN 55011 class B
Static discharge
ESD 8kV contact discharge, 15kV free air discharge
ref. IEC 61000-4-2
EN 61000-4-2
Electromagnetic fields
10 V/m
ref. IEC 61000-4-3
EN 61000-4-3
Burst
4 kV input, 2kV output/capacitive coupling clamp
ref. IEC 61000-4-4
EN 61000-4-4
Surge
4 kV unsymmetrical, 4 kV symmetrical
ref. IEC 61000-4-5
EN 61000-4-5
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 167
AS-i Safety
Output voltge
Price Lists
Article no.
of approx. 60°C with nominal load. With higher temperatures the
output voltage, that is the total power is adjusted and so the
power supply is protected from destruction.
Other Fieldbuses/
Master Simulators
The power supply is continous idle running protected and thus
dellivers a variable direct current of 0 - 8 A as output current.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW2276 AS-i Wide Range Power Supply 8 A
AS-i Master/Gateways/
Links/Scanner
AS-i Wide Range Power Supply 8 A
Conducted disturbances
10V, 150 kHz ... 80 MHz
ref. IEC 61000-4-6
EN 61000-4-6
Operational data
Temperature range
-10°C ... +40°C, by free convection
Power derating
2,5% / K from +40°C to max.70°C (see diagram)
Storage temperature
-25°C ... max. +85°C
Displays
LED green
LED on: normal operation (0 A ... 8 A)
LED red
LED on: overload
LED flashing: hicc-up mode
Mounting
Mounting position
vertical as shown in figure
Input terminals
upper side
Output terminals
lower side
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Assembly
plastic slider
Mechanics
Dimensions max. (L / W / H in mm)
70 / 141 / 151
Weight
approx. 1,2 kg
Derating
Current limitation curve
Output voltage
Output power
100%
100%
ca. 60%
Automatic restart
hicc-up mode
Other Fieldbuses/
Master Simulators
25%
4 0 °C
7 0 °C
Ambient temperature
Connections
100%
Output current
Diagram
PE
L1
141
AS-i Safety
L2
LED Power
LED Overload
AS-i _
AS-i +
Price Lists
Ground
70
151
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 168
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
24 V to 30 V AS-i Power Supply
in Stainless Steel 2 A
AS-i-Master/Gateways/
Links/Scanner
24 V DC to 30 V AS-i Output Voltage
PELV
LED operation indicator
AS-i data decoupling
62 Watt
Article No. BW1760
Article no.
The power supply provides an output current of 2 A.
BW1760
Input
Operating voltage Ue
24 V DC
Input voltage range Ue
20 .. 32 V DC
Fuse
T 6,3 A built-in
Short circuit protected
yes
Overload protected
yes
Output
Output voltage (AS-i)
29,5 V .. 31,6 V DC according PELV
Output current
2 A (3 A up to 30°C)
Remaining ripple
< 50 mV
Efficiency
88%
Hold-up-time
> 10 ms
Pre-fuse
> 10 A
Connections:
AS-i
+ -
24 V
+ -
Displays
LED green
power on (at frontside)
LED red
overload error
Temperatur performance, derating 3 A:
Other Fieldbuses/
Master Simulators
The AS-i Power Supply in Stainless Steel supplies the
AS-i system voltage for the supply of masters, sensors,
actuators and modules.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Insertable Combicon connectors
Housing
Storage temperature
0°C .. +55°C
-25°C .. +85°C
Connection
insertable Combicon connectors up to 2,5 mm²
Housing
stainless steel
Protection category (EN 60 529) IP20
Dimensions (L, W, H)
120 mm, 55 mm, 83 mm
Standard conformity
Standards
EN 50295, EN 61000-6-2, EN 61000-6-4
Mounting position
vertical
AS-i Safety
Ambient operating temperature
Note: Air circulation in the power supply may not be disturbed:
Price Lists
therefore when mounting see that is at least 3 cm free space
down and sufficiently free space above!
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 169
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
4A/8A Power Supply for AS-i Master
in Stainless Steel
4 A/8 A Power Supply for
AS-i Master in Stainless Steel
for 2 AS-i Circuits
LED operation indicator
At present for
This supply for AS-i powers one respectively two fully loaded AS-i
systems with a maximum output current of 4 A respectively 8 A.
These power supplies are qualified only for the gateways in stainlees steel in the version "1 power supply for 2 AS-i circuits“.
The power supplies are continous idle running protected and can
deliver therefore a variable direct current of 0 - 4 A (BW1597)
resp. 0 - 8 A (BW1593/BW1598) as output current.
Article no.
BW1593
BW1598
Class1 Div2
(Group A, B, C &
D, T-Code 4)
30 V 8 A
BW1597
Class1 Div2
(Group A, B, C & D,
T-Code 4)
30 V 8 A
30 V 4 A
Input
Operating voltage
Input current
115/230 V AC, 47 - 63 Hz
93 - 132 V AC/187 - 265 V AC, 47 - 63 Hz
1,8 A at 230 V AC/4,2 A at 115 V AC
Turn on impulse
Fuse
Power factor cos ϕ
0,9 A at 230V AC/2,2 A at
115 V AC
< 30 A
T 6,3 A/250 V internal
T 3,15 A/250 V internal
0,5 capacitively at 230 V AC/0,58 capacitively at 115 V AC
PFC standard (harmonic waves)
EN 61 000-3-2
Output
30 VDC ± 1%
Output voltage
Output current
8A
Ripple
Current limitation (typ.)
Efficiency (typ.)
Hold-up-time
4A
< 50 mVpp
12 A
Parallel use
AS-i Safety
BW1597
Article no. BW1593 8 A
Article no. BW1598 8 A Class1 Div2 (Group A, B, C & D, T-Code 4)
Article no. BW1597 4 A Class1 Div2 (Group A, B, C & D, T-Code 4)
Voltage range
Other Fieldbuses/
Master Simulators
BW1593/1598
BWU1569, BWU1643, BWU1652, BW1197,
BW1477, BWU1820, BWU1823, BWU1833
6A
yes
90 %
89 %
> 35 ms/230 V AC; > 30 ms/115 V AC
> 20 ms/230 V AC;
> 15 ms/115 V AC
Displays
LED green
LED red
Ambient operating temperature
Storage temperature
Protection (IEC)
power on (at frontside)
overload error (at frontside)
0°C … +60°C
-25°C … +85°C
IP20
Electromagnetic compatibility
Price Lists
Signal error
Interference resistence
radio-screened according EN 55022 class B
EN 50 082-1/EN 50 082-2, continous short circuit and idle running protected
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 170
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
BW1597
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW1593
BW1598
AS-i-Master/Gateways/
Links/Scanner
4A/8A Power Supply for AS-i Master
in Stainless Steel
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 171
AS-i Master/Gateways/
Links/Scanner
4 A Power Supply with 3 Phases for
AS-i Master in Stainless Steel
4 A Power Supply with 3 phases for
for AS-i Master in Stainless Steel
for 2 AS-i circuits
LED operation indicator
At present for
BWU1569, BWU1643, BWU1652, BW1197,
BW1477, BWU1820, BWU1823, BWU1833
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1927
The power supply with 3 phases for AS-i powers one respectively
two fully loaded AS-i systems with a maximum output current of 4 A.
The power supply is continous idle running protected and can
deliver therefore a variable direct current of 0 - 4 A as output current.
Article no.
These power supplies are qualified only for the gateways in stainless steel in the version "1 power supply for 2 AS-i circuits“
BW1927
Temperatur performance:
Input
Operating voltage
3 x 400 - 500 VAC, 47 - 63 Hz
Voltage range
3 x 340 - 576 VAC, 47 - 63 Hz
Input current
3 x 0,5 A at 400 VAC
Turn on impulse
< 25 A (at cold start, 575 VAC)
Prescribed external fusing
circuit breaker with B-characteristic 3 x 10 A or slower
action, or alternatively 3 x 10 A HBC fuse
Internal fusing
-
Output
Other Fieldbuses/
Master Simulators
Output voltage
30,5 VDC ± 3%
Accuracy of regulation
2%
Output current
0-4A
Ripple
< 25 mVpp
Current limitation at 60°C
typ. 4.2 - 7,4 A
Derating (TU =60°C - 70°C)
typ. 6 W/K
Parallel operation
yes; no equal load sharing
Short-circuit protected
yes
Overload protected
yes
Efficiency (typical)
89%
Connections:
FE
30 V DC
Price Lists
AS-i Safety
Display
LED
power on (at frontside)
Housing
stainless steel
Ambient operating temperature -10°C ... +70°C
Storage temperature
-25°C ... +85°C
Protection category EN 60529 IP20
Dimensions (L, W, H)
117 mm, 73 mm, 124 mm
Standards
EMC:
EN 61000-6-3, EN 61000-6-4,
EN 61000-6-2, EN 61000-6-1, VDE 0160/W2
Safety:
EN 60950-1, EN 60204-1, EN 50178,
IEC 60950, UL 60950, UL 508,
CAN/CSA-C22.2 No. 60950 (CUR),
CAN/CSA-C22.2 No. 14 (CUL)
Power factor (PFC):
EN 61000-3-2
Ue 1 - 3
FE
FE
Note:
Air circulation in the power supply may not
be disturbed: therefore when mounting see
that is at least 50 mm free space below/
above and 15 mm free space left/right!
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 172
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
8 A Power Supply with 3 Phases for
AS-i Master in Stainless Steel
LED operation indicator
At present for
BWU1569, BWU1643, BWU1652, BW1197,
BW1477, BWU1820, BWU1823, BWU1833
Article no. BW1676
The Power Supply with 3 phases for AS-i powers one respectively
two fully loaded AS-i systems with a maximum output current of 8 A.
The Power Supply is continous idle running protected and can
deliver therefore a variable direct current of 0 - 8 A as output current.
Input
Operating voltage
Voltage range
Input current
Turn on impulse
Fuse
Power factor cos ϕ
PFC standard (harmonic waves)
Output
Output voltage
Output current
Ripple
Current limitation (typ.)
Parallel use
Efficiency (typ.)
Hold-up-time
Displays
LED green
LED red
Housing
BW1676
3 x 380 - 500 V AC, 47 - 63 Hz
3 x 340 - 550 V AC, 47 - 63 Hz
3 x 0,7 A at 400 V AC
< 50 A
0,55 capacitively at 230 V AC
EN 61 000-3-2 class A
30 VDC ± 1%
0-8A
< 50 mVpp
12,5 A
yes
90%
> 5 ms/400 V AC
power on (at frontside)
Other Fieldbuses/
Master Simulators
Article no.
These Power Supplies are qualified only for the gateways in stainlees steel in the version "1 power supply for 2 AS-i circuits“.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
8 A Power Supply with 3 phases for
for AS-i Master in Stainless Steel
for 2 AS-i circuits
overload error (at frontside)
Ambient operating temperature
-10° C ...+70° C, by free convection
Storage temperature
-25° C...+85° C
Signal error per:
radio-screened according EN 55 011 class B
Interference resistence per:
EN 50 082-1/EN 50 082-2,
continous short circuit and idle running protected
Price Lists
Attention: Max: output power 240 W at setting to 30 V DC max. 8 A
AS-i Safety
Elektromagnetic Compatibility
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 173
AS-i Master/Gateways/
Links/Scanner
AS-i Power Supply Decoupling Unit: Supply
of 2 AS-i Networks via 1 Power Supply
AS-i Power Supply Decoupling Unit for 2 AS-i Networks
AS-i Power Extender for 2 AS-i networks
Applicable with double masters
without integrated data decoupling
Supply of 2 AS-i networks out of 1 power supply
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP20
Article no. BWU1943: Supply 2 AS-i networks out of 1 power supply
The AS-i Power Supply Decoupling Unit was developed for the
use with double masters without integrated data decoupling in
the master. It is used to decouple the power supply in order to
power up 2 AS-i networks with only 1 AS-i Power Supply.
The data decoupling unit built inside the AS-i Power Supply
Decoupling Unit is limited to 4,0 A at 30 V for each network.
The AS-i Power Supply Decoupling indicates the AS-i voltage at
the inputs with two LEDs in two steps:
The AS-i Power Supply Decoupling Unit can also be used in combination with a repeater. It has an IP20 housing.
1. AS-i voltage > 28 V
Several AS-i Power Supply Decoupling Units can be supplied out
of 1 power supply.
2. AS-i voltage > 26 V
AS-i Power Supply Decoupling Unit is short circuit protected
(self-recovering fuse, 6 A).
The DC line from the power supply must not be grounded!
Article no.
BWU1943
Connections
30 V input voltage
AS-i output voltage
Function earth
Other Fieldbuses/
Master Simulators
Display
LED green (PWR)
AS-i voltage (circuit 1) ON
LED green (PWR)
AS-i voltage (circuit 2) ON
LED green (U AS-i)
AS-i voltage > 28 V
LED green (U AS-i)
AS-i voltage > 26 V
Operating current
< 4,0 A at 30 V (per output)
Operating voltage
30 V DC (PELV)
Voltage of insulation
≥ 500 V
EMC directions
EN 61000-6-2, EN 61000-6-4
AS-i Safety
Operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Housing
housing for DIN rail mounting
Dimensions (L, W, H)
99 mm, 22,5 mm, 92 mm
1 2
PWR
U> U>
28V 26V
AS-i1 AS-i1 AS-i2 AS-i2
+
+
NC +30V 0V FE
Protection category (DIN 40 050) IP20
Weight
120 g
Accessories:
• AS-i Power Supply 4 A (article no. BW1649, see also page 166)
• 8 A Power Supply for AS-i Master in Stainless Steel for 2 AS-i circuits (article no. BW1593, see also page 170)
• 8 A Power Supply with 3 Phases for AS-i Master in Stainless Steel for 2 AS-i circuits (article no. BW1676, see also page 173)
• AS-i Advanced Repeater (article no. BW1855, see also page 157)
Price Lists
• 24 V to 30 V AS-i Power Supply in Stainless Steel 2 A (article no. BW1760, see also page 169)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 174
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Power Extender
AS-i-Master/Gateways/
Links/Scanner
Extends the distance between AS-i Power
Supply and AS-i Network
Can be used in combination with
Repeater/Extender
AS-i Power Extender and AS-i Gateway in IP65
Power Supply remains in IP20
Various AS-i networks can be powered by
one power supply
As rule of thumb für die AS-i cable length in dependence of the AS-i
voltage compared with conventional AS-i network (cable cross-section: 1,5 mm², for example with AS-i flat cable):
1. AS-i voltage > 28 V: approx. 80 m cable length
2. AS-i voltage > 26 V: approx. 60 m cable length
Inside the AS-i Power Extender you can find a data decoupling for
max. 2,8 A/4,0 A current with 30 V AS-i voltage. The AS-i Power
Extender is short circuit protected (self-recovering fuse, idle,
3 A/6 A).
The AS-i Power Extender was developed for the use in combination
with repeater/extender. The AS-i Power Extender is located in an
IP65 housing with a substructure module.
In combination with gateways in IP65 you can easily build up small
decentral islands.
The AS-i Power Extender is used to extend the distance between
the power supply and the actual AS-i network.
Either an AS-i Power Supply or a standard power supply with 30 V
according to AS-i specification can be used to power the remote
AS-i network.
The AS-i Power Extender has to be connected in between of the
Power Supply on one side and the AS-i Master and slaves on the
other side.
In dependence on cable resistor and current there is a voltage drop
between the power supply and the AS-i Power Extender. The AS-i
voltage at the AS-i Power Extender's output is displayed with the
help of two LEDs.
1. AS-i voltage at the AS-i Power Extender > 28 V
2. AS-i voltage at the AS-i Power Extender > 26 V
As with normal AS-i networks the user has to make sure that actuators have ot be powered with 24 V +10%/-15%.
Article no.
BW1197 BW1713
Connections:
30 V input voltage
AS-i output voltage
Function earth
standard AS-i substructure module for the connection of the
AS-i cable and the external power supply
cage clamp
Display:
LED green
LED green
Operating current
Operating voltage
Voltage of insulation
EMC directions
Ambient operating temperature
Storage temperature
Housing
Dimensions (L, W, H)
3A
6A
AS-i voltage > 28 V
AS-i voltage > 26 V
< 2,8 A at 30 V
Accessories:
AS-i substructure module for the
connection to the AS-i flat cable
and the flat cable for 24 V DC
(article no. BW1181, see also
page 183).
AS-i substructure module for the
connection to the AS-i round cable
and the round cable for 24 V DC
(article no. BW1183, see also
page 183)
< 4,0 A at 30 V
30 V DC (PELV)
≥ 500 V
EN 50082, EN 50081
0°C … +70°C
-25°C … +85°C
housing for DIN rail mounting
45 mm, 80 mm, 70 mm
Protection category (DIN 40 050)
IP65
Weight
120 g
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 175
Price Lists
Short circuit protection
(self-recovering fuse)
BW1477 BW1714
Other Fieldbuses/
Master Simulators
Article no. BW1197: AS-i Power Extender 2,8 A
Article no. BW1713: AS-i Power Extender 2,8 A, Class I Div. 2 (Group A, B, C & D, T-Code 4)
Article no. BW1477: AS-i Power Extender 4,0 A
Article no. BW1714: AS-i Power Extender 4,0 A, Class I Div. 2 (Group A, B, C & D, T-Code 4)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Accessory: Art. no. BW1183
AS-i Safety
Accessory: Art. no. BW1181
AS-i Module for Power Decoupling
24 V DC (UAUX) power supply out of AS-i
(1,2 A max. by 24 V)
in combination with an AS-i Repeater:
decouples 1,2 A from AS-i Segment B
and supplies Segment A with 1,2 A
Article no. BW2387 AS-i Module for Power Decoupling
With the help of the AS-i Modules for Power Decoupling it is possible to take out up to 1,2 A current (approx. 24 V) out of AS-i.
The help energy can be used for supply of ventils or other consumers. With the help of the AS-i Module for Power Decoupling
it may be waived of conducting additional 24 V help energy to
bad accessible places.
In combination with an repeater it decouples 1,2 A from AS-i Segment B and supplies Segment A with 1,2 A.
The impedance load of the module corresponds with that of 5
AS-i slaves. This reduces the maximum possible number of
slaves for AS-i Segment B to 26 (Single) or 52 (AB).
The AS-i Module for Power Decoupling is short circuit proofed.
Article no.
BW2387
Connections:
Connections
COMBICON clamps
1
AS-i A-out
AS-i voltage
26,5 ... 31,6 V via AS-i
2
AS-i A+out
Max. AS-i current consumption
1,5 A
3
DC-
DC- / DC+
20 … 30 V DC
4
DC+
Loading capacity
1,2 A
5
n.c.
AS-i impedance
5 single slave load
… …
OVERLOAD (red)
overload cut-off active
12 n.c.
U > 26 V (green)
U AS-i Segment A > 26 V
13 AS-i B+in
U > 17,5 V (yellow)
U AS-i Segment A > 17,5 V
14 AS-i B-in
Applied standards
EN 61 000-6-2
EN 61 000-6-3
15 FE
Operating temperature
-25 … +55 °C
16 FE
Storage temperature
-25 … +70 °C
Protection category EN 60 529
IP20
Allowable shock and
vibration stress
≤ 15 g, T ≤ 11 ms
10 … 55 Hz, 0,5 mm amplitude
Dimensions (L / W / H in mm)
114 / 22,5 / 99
Weight
-
AS-i – AS-i + DC –
out
out
DC +
AS-i Segment A + DC
OVER
LOAD
U>
U>
17,5V 26V
AS-i Segment B
AS-i + AS-i in
in
FE
FE
Terminals
Description
AS-i+, AS-i-
Connection to the AS-i bus
DC+, DC-
Voltage input,
Voltage output
FE
Function earth
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Module for Power Decoupling
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 176
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Module for Power Decoupling
1,2 A
approx. 24 V (UAUX)
24 V DC appliance
AS-i -/+ DC -/+
out
BW2387
AS-i +/in
FE
1,2 A
AS-i Segment B
Impedance load is equivalent to 5 slaves
2) in combination with an AS-i repeater:
decouples 1,2 A from AS-i Segment B and supplies Segment A with 1,2 A
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
1) 24 V DC (UAUX) power supply out of AS-i(1,2 A max. at 24 V)
AS-i-Master/Gateways/
Links/Scanner
Connection examples:
1,2 A
AS-i -/+ AS-i -/ +
AS-i -/+ DC -/+
out
BW2192
BW2387
AS-i +/- AS-i +/-
AS-i +/in
FE
AS-i Safety
1,2 A
Other Fieldbuses/
Master Simulators
AS-i Segment A
1,2 A
1,2 A
Impedance load is equivalent to 5 slaves
Price Lists
AS-i Segment B
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 177
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 178
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Profile Cables/Passive Distributors/
Substructure Modules/Accessories
AS-i Profil Cable
BW1979
with a yellow jacket for data and power transmission
BW1980
with a black jacket for additional auxiliary energy
BW1239
passive distributor AS-i on M12
BW1976
passive distributor AS-i/24 V on M12
BW1977
passive distributor AS-i on M12, 2 m line
BW1974
passive distributor AS-i/24 V on M12, 2 m line
BW1975
passive distributor AS-i flat cable branch
BW1180
to connect 2 AS-i flat cables
BW1438
to connect 2 AS-i flat cables with addressing socket
BW1439
to connect 1 AS-i flat cable, 1 flat cable for
additional supply with addressing jack
BW1181
to connect 1 AS-i flat cable, 1 flat cable for
additional supply
BW1182
to connect 2 AS-i round cables
BW1183
to connect 1 AS-i round cable, round cable for
additional supply
BW1946
lid for standard AS-i substructure modules
BW1945
AS-i ribbon cable seal for PG11 fittings
AS-i Passive Distributors
P.
181
182
183
Price Lists
AS-i Substructure Modules
Characteristics
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art. No.
Other Fieldbuses/
Master Simulators
Component
AS-i Safety
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i profil cables/passive distributors/substructure modules/accessories
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 179
AS-i Profile Cables/Passive Distributors/
Substructure Modules/Accessories
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Housing
Component
Art. No.
AS-i Cable-Stripper
BW1920
for AS-i cable with rubberized insulation
AS-i Micro-Wire-Stripper
BW1921
for AS-i cable with an external insulation
made of TPE or PUR
D-sub-data transmission cord for
AS-i Master in IP65
BW1097
D-sub-data transmission cord 9-pin
BW1058
D-sub-data transmission cord for
AS-i Gateways with CAN interface
BW1226
AS-i addressing cable
BW2324
with COMBICON connector
BW1935
with infrared addressing adapter
Connecting cable
BW1802
Module/programming device
Protection cap
BW2368
Reduction sleeve
BW1745
AS-i probe
BW2079
memory capacity 32 kByte
BW2222
memory capacity 128 kByte
Price Lists
AS-i Safety
PG16/M18x1
M25/M18x1
AS-i probe
184
for not used M12 sockets
BW1241
BW1304
P.
185
BW1282
Cross-Link-cable for AS-i/Ethernet
Gateway
Chip card
Characteristics
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 180
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Profile Cable
AS-i-Master/Gateways/
Links/Scanner
AS-i Profile Cable
Versions:
• with a yellow jacket
for data and power transmission (BW1979)
BW1979
• with a black jacket
for additional auxiliary energy (BW1980)
BW1980
High-flex life expectation
Oil-resistance
Fire protection
Article no. BW1979: AS-i Profile Cable yellow, 100 m
Article no. BW1980: AS-i Profile Cable black, 100 m
AS-i cables are specially designed for use in these low levels of
plant automation and allow data and power transmission at the
same time. The cable can be installed in equipment such as push
buttons and sensors. Due to its profiled design it is resistant to
polarity reversal and can be easily connected to the slave interfaces at any place.
The cable is available in two versions: with a yellow jacket
(BW1979) for data and power transfer, and a black jacket
(BW1980) variant for additional auxiliary energy.
Mechanically, this makes them absolutely comparable with rubber-jacketed cable variants – but it’s the magic of TPE that guarantees important properties such as oil-resistance and the right
level of fire protection along with high-flex performance.
BW1979
BW1980
TPE made cable for the use in plant automation
AS-i
UAUX
Conductor
stranded tinned copper wire 84 x 0.15, Ø 1.5 mm
Insulation
insulation of TPE, Ø 2,5 mm
Insulation color
Jacket
Thickness of insulation
BN, BU
thermoplastic elastomer compound (TPE) yellow thermoplastic elastomer compound (TPE) black
ca. 0,5 mm
Conductor resistance
13,7 Ohm/km
Insulation resistance
1 MOhm/km
Operating voltage (peak)
Standards
Delivery length
Other Fieldbuses/
Master Simulators
Application
Signal transmission
An important value for the industrial application field is the highflex life expectation for all AS-i profile cables: ten million cycles of
repeated bending are possible without any signs of degradation.
300 V
flame retardant acc. to IEC 60332-1-2 and UL 758, page 95
oil and cut oil resistant acc. to UL 758, sec. 15
cold bending resistant acc. to IEC 60811-1-4
UL-Style 2103, CSA-File LL55255-42
100 m (ring)
Price Lists
Cross section
AS-i Safety
Art. no.
The cable jacket is made of TPE.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL and CSA certificated
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 181
AS-i Passive Distributor
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Passive Distributor
•
•
compact design
simple and fast mounting
BW1974, BW1976, BW1977, BW1975:
•
•
•
•
•
immunity to vibration
fixing component with captive screw
gold plated contacts
housing made of fibre optics-reinforces plastic
reverse polarity protected
and yellow marking for AS-i flat cable
BW1977
BW1974
BW1975
Article no. BW1239: Passive Distributor AS-i on M12
Article no. BW1976: Passive Distributor AS-i/24 V on M12
Article no. BW1977: Passive Distributor AS-i on M12, 2 m line
Article no. BW1974: Passive Distributor AS-i/24 V on M12, 2 m line
Article no. BW1975: Passive Distributor AS-i flat cable branch
AS-i Passive Distributors are characterised by a compact design.
They offer a cost-effective, space-saving, fast and variable pos-
Technical data
Flat cable terminals
Other Fieldbuses/
Master Simulators
BW1976
Oil and abrasion resistant PUR line (BW1974,
BW1977)
appropriate for conveyor chains
Plug-and-socket connection
BW1239
sibility to install many initiators or actuators on narrowest room in
the type of protection IP67.
BW1976
BW1977
socket M12 x 1 (V1)
1 x AS-i
BW1974
plug M12 x 1 (V1), angled
1 x AS-i/1 x UAUX
1 AS-i
1 x AS-i/1 x UAUX
BW1975
–
2 x AS-i
insulation penetration technology
≤ 35 V PELV ( AS-i, UAUX )
Rated operational voltage
Rated operational current
≤2A
≤4A
≤8A
Ambient operating temperature
-25 ... 75 °C
Storage temperature
-25 ... 85 °C
Protection degree
IP67
Connector
–
PUR, black
–
Cable
–
PUR, halogen-free
–
Sheath diameter
–
Ø 4,8 mm
–
Colour
–
grey
–
Cores
–
Length
Dimensions (L / W / H in mm)
Tightening torque, fixing screws
2 x 0,34 mm2
–
50 / 20 / 30
4 x 0,34 mm2
2m
40 / 36 / 40
–
–
40 / 36 / 19
0,8 Nm
Diagram
Price Lists
AS-i Safety
BW1239
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 182
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Substructure Module
AS-i-Master/Gateways/
Links/Scanner
AS-i Substructure Module
Mounting on DIN rail and rear panel
for connection of AS-i flat cables:
• quick mounting technology for AS-i flat cable
BW1180
BW1438
BW1181
BW1439
BW1182
BW1183
BW1946
BW1945
• 2 AS-i flat cables (BW1180)
• 2 AS-i flat cables with adressing jack (BW1438)
for connection of AS-i round cables:
• screw terminal
• 2 AS-i round cables (BW1182)
• 1 AS-i round cable,
1 round cable for external power supply (BW1183)
Lid for standard AS-i substructure modules (BW1946)
AS-i ribbon cable seal for PG11 fittings (BW1945)
Article no. BW1180 for connection of 2 AS-i flat cables
Article no. BW1438 for connection of 2 AS-i flat cables with addressing socket
Article no. BW1439 for connection of 1 AS-i flat cable, 1 flat cable for external auxiliary power with
addressing jack
Article no. BW1181 for connection of 1 AS-i flat cable, 1 flat cable for external power supply
Article no. BW1182 for connection of 2 AS-i round cables
Article no. BW1183 for connection of 1 AS-i round cable, 1 round cable for external power supply
Article no. BW1946 lid for standard AS-i substructure modules
Article no. BW1945 ribbon seal for PG11 fittings
Article no.
BW1180
BW1438
With the use of the lid for standard AS-i modules further passive
branches can be built up.
AS-i ribbon cable seal is used for packing of PG11 fittings for AS-i
flat cable.
BW1181
BW1439 BW1182 BW1183
Cable
2 AS-i flat cables
1 AS-i flat cable
2 AS-i round cables
Gauge
–
–
< 2,5 mm2
Connection
contact pins in the unit
Contact rating
Operating voltage
AS-i
Ambient operating temperature
-25 ... 75 °C
Storage temperature
-25 ... 85 °C
Protection category
–
–
AS-i/U AUX
–
–
IP65
80 / 45 / 20
80 / 45 / 34
80 / 45 / 13
–
Price Lists
Dimensions (L / W / H in mm)
–
<4A
AS-i/U AUX
BW1945
2
terminals up to 2,5 mm
<2A
AS-i
BW1946
AS-i Safety
AS-i substructure modules are some necessary accessories for
AS-i modules of the product family IP65 M12- and IP65 PG-modules. They are available in versions for connection of AS-i flat and
round cables.
Other Fieldbuses/
Master Simulators
• 1 AS-i flat cable,
1 flat cable for external power supply with addressing jack
(BW1439)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
• 1 AS-i flat cable,
1 flat cable for external power supply (BW1181)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 183
AS-i Stripping Tools
AS-i Master/Gateways/
Links/Scanner
AS-i Cable-Stripper:
for AS-i cables with rubberized insulation
AS-i Micro-Wire-Stripper:
for AS-i cables with an external insulation
made out of TPE or PUR
AS-i Cable-Stripper (BW1920)
AS-i Micro-Wire-Stripper (BW1921)
The AS-i Cable-Stripper is the latest development for removing
rubber made outer sheathing of AS-i cable.
The blades have got the same shape as the AS-i cable and allow
an accurate stripping without any problems. For removing the
insulation put in the cable, close and press the tool. The special
blades do not cause any damage to the inner conductors. Those
can be stripped with the additional blades at the side of the tool.
The AS-i Micro-Wire-Stripper is the latest development for
removing the outer sheath of AS-i cable, which is made of TPE
or PUR.
The tool strips AS-i cables without any problems, because the
blades follow the special shape of the cable.
The pliers‘ body is made out of fibreglass-reinforced polyamide in
an ergonomic and automatic design. Adjustment onto the cable
is not necessary since the special hardened blades adjust themselves.
Article no.
BW1920
BW1921
Main using
for AS-i cable with rubberized insulation
for AS-i cable with an external insulation made of TPE or PUR
Length
125 mm
160 mm
Weigth
50 g
120 g
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1920: AS-i Cable-Stripper
Article no. BW1921: AS-i Micro-Wire-Stripper
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 184
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Accessories
-
PIN
Function
Colour
Article no. BW1097
1
PE
Connection
RS 485 prefabricated cable
2
SHIELD
Storage temperature
-40°C … +85°C
3
3
BUS P
green
Operating temperature
-25°C … +60°C
4
8
BUS N
yellow
5
5
GRND
blue
Protection category (IEC)
EN 60 529
connector IP65,
plug IP20
PE
Dimensions (L, W, H)
ca. 50 mm, 20 mm, 30 mm
7
SHIELD
Length
1,5 m
8
BUS P
6
9
10
BUS N
6
+5 V
red
D-sub-data transmission cord 9-pin, 1,8 m
Article no. BW1058
Connection
D-Sub plug
D-Sub socket
Length
1,8m
PIN 1 connected with PIN 1
D-sub-data transmission cord for AS-i Gateways with CAN interface
AS-i/CAN Gateway
Clamps
PIN
1
2
7
3
4
5
Function
Colour
n.c.
2
CAN_H
Article no. BW1226
Connection
white
D-subsocket,
5-pin COMBICON plug
SHIELD
Operating temperature
-40°C … +85°C
CAN_L
Storage temperature
-25°C … +60°C
Protection category (IEC)
EN 60 529
IP20
n.c.
brown
Dimensions (L, W, H)
ca. 50 mm, 20 mm, 30 mm
Length
1,5 m
AS-i addressing cable (with COMBICON connector) for direct addressing with AS-i master
Article no. BW2324
round connector 2-pin
COMBICON-connector
Length
1,5 m
Connector (Master)
+ AS-i -
Price Lists
Connection
Other Fieldbuses/
Master Simulators
Clamps
AS-i Safety
AS-i Master in IP65 (Specification 2.0)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
D-sub-data transmission cord for AS-i Master in IP65, 1,5 m
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 185
AS-i Master/Gateways/
Links/Scanner
Accessories
AS-i addressing cable - infrared addressing adapter
Article no. BW1935
Connection
infrared head/M12 connector
Length
1m
Connecting cable (Module/programming device)
Article no. BW1802
Connection
round connector 2-pin/
M12 connector
Length
1,6 m
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection cap for not used M12 sockets
Article no. BW2368
Colour
blue
Packing unit
50 pieces
Reduction sleeve PG16/M18x1
Article no. BW1241
Material
Stainless steel
Reduction sleeve M25/M18x1
Article no. BW1282
Material
Brass
Cross-Link-cable for AS-i/Ethernet Gateway
Other Fieldbuses/
Master Simulators
Article no. BW1304
AS-i Probe
Price Lists
AS-i Safety
Article no. BW1745
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 186
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Accessories
Article no.
Memory capacity
Labeling on the chip card
BW2079
BW2222
32 kByte (256 bit)
128 kByte (1024 bit)
C 256
Weight
Dimensions (L / W / H in mm)
Accessories for the following
devices
C 1024
approx. 1 g
AS-i-Master/Gateways/
Links/Scanner
Chip card for Bihl+Wiedemann AS-i products
25 / 15 / 1
BWU2044
BWU2186
BWU2027
BWU2187
BWU2109
BWU2188
BWU2001
BWU2002
BWU2003
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
BWU2004
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU2000
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 187
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 188
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Development/Manufacturing of
AS-i Components
Component
Art. No.
AS-i 3.0 Function and EMC-Test
Master
BW1728
with master RS 232
suitable for SAP4, SAP5, A2SI and ASI4U
190
AS-i 3.0 SAP4, SAP5, A²SI and ASI4U
Programming and Test Tool
BW1783
Compact PCI Board
191
BW2061
PCI Board with RS 232
BW1423
on basis ASI-SW+
192
BW1190
on basis A²SI
193
P.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Slave Evaluation Board
Characteristics
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview Development/Manufacturing of AS-i Components
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 189
AS-i 3.0 Function and EMC-Test Master
AS-i Master/Gateways/
Links/Scanner
AS-i-Master
Suitable for SAP4, SAP5, A2SI and ASI4U
For programming, developing and
tests of AS-i Slaves
AS-i specification 3.0
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BWU1728 with Master RS 232
The AS-i Function and EMC-Test Master with RS 232 interface can be operated in 3 different modes:
1. As a standard AS-i Master according to specification 3.0.
2. As a tool for programming of the AS-i Slave ICs SAP4, SAP5, A2SI and ASI4U. This can be done with the help of Windows programs.
3. As a means to perform function and EMC tests which are necessary for every development of an AS-i slave (EMC test mode).
The AS-i Function and EMC-Test Master is used among others for the AS-i certification in Leipzig for release and test of AS-i Slaves.
Graphical display
Art. no. BWU1728
Operating current
Master power supply
approx. 200 mA out of AS-i circuit
Operating voltage
AS-i voltage 30 V DC
Baud rates
19200 Baud
Serial interface
RS 232
AS-i cycle time
150 μs*(number of slaves + 2)
Displays
LCD
displaying slave addresses, error messages
LED green (power)
power on
LED green (ser active)
serial interface active
LED red (config error)
configuration error
LED green (U AS-i)
AS-i voltage OK
LED green (AS-i active)
AS-i normal operation active
LED green (prg enable)
automatic address programming enabled
LED yellow (prj mode)
the master in configuration mode
Buttons
4
Voltage of insulation
≥ 500 V
EMC directions
EN 61000-6-2, EN 61000-6-4
Ambient operating temperature
The EMC-Test Mode
It is possible to put the Master into a state that is
not AS-i compliant. This option can be useful for
specific tests on AS-i under laboratory conditions
(e. g. tests with bursts on the lines or tests with
very long wires).
By putting the AS-i Master into the EMC Test
Mode it becomes an AS-i test set-up for experts.
In the test mode, the list of addressed slaves and
the telegrams for contacting these slaves are
given by the host. Also, it is possible to decide
from within the host whether faulty answered telegrams from the AS-i Master may be repeated or
not (Note: in regular AS-i operation, data telegrams can be repeated one time). As above,
there are two error counters. However, in this
mode the first one counts all telegrams while the
second counts all faulty telegrams.
The AS-i_EMC.EXE program is designed for the
operation of the AS-i Master in the EMC test
mode. This program is also delivered as program
for Windows.
0°C ... +55°C
Storage temperature
-25°C ... +85°C
Housing
AS-i master housing in stainless steel
Dimensions (L, W, H)
120 mm, 75 mm, 83 mm
AS-i Safety
Protection category (DIN 40050) IP20
Tolerable loading reffering to
impacts and vibrations
according to EN 61 131-2
Weight
460 g
Individual software:
It is, of course, possible to operate the AS-i Master from other hosts with individual software. The neccessary telegrams are described
in the manual.
Scope of delivery:
• The AS-i Function and EMC-Test Master with RS 232, power supply A
Price Lists
• Windows program AS-i_EMC.EXE for EMV test mode
• Windows programs for programming of SAP4, SAP5, A2SI and ASI4U
• Software AS-i Control Tools with serial cable for AS-i master in stainless steel (art. no. BW1602, s. page 56)
A DLL-driver for the programming of the A²SI- and SAP4-ASIC can be ordered seperately on request (art. no. BW1356)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 190
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 SAP4, SAP5, A2SI and ASI4U
Programming and Test Tool
For programming,
developing and
testing of AS-i Slaves
AS-i Specification 3.0
BW1783
BW2061
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 SAP4/5, A²SI, ASI4U
Programming and Test Tool
The AS-i 3.0 Programming and Test Tool can be operated in 3 different modes:
two error counters. However, in this mode the first one counts all telegrams while the second counts all faulty telegrams.
• As a standard AS-i Master according to specification 3.0.
The AS-i_EMC.EXE program is designed for the operation of the AS-i
Master in the EMC test mode. This program is also delivered as program for Windows.
A2SI and ASI4U. This can be done with the help of Windows programs.
• As a means to perform function and EMC tests which are necessary for every development of an AS-i slave (EMC test mode).
The EMC-Test Mode
It is possible to put the Master into a state that is not AS-i compliant.
This option can be useful for specific tests on AS-i under laboratory
conditions (e. g. tests with bursts on the lines or tests with very long
wires).
By putting the AS-i Master into the EMC Test Mode it becomes an
AS-i test set-up for experts.
In the test mode, the list of addressed slaves and the telegrams for
contacting these slaves are given by the host. Also, it is possible to
decide from within the host whether faulty answered telegrams from
the AS-i Master may be repeated or not (Note: in regular AS-i operation, data telegrams can be repeated one time). As above, there are
Technical data
Type
Interfaces
It is, of course, possible to operate the AS-i Master from other hosts
with individual software. The neccessary telegrams are described in
the manual.
BW1783
BW2061
Requirements:
Compact PCI Board
PCI Board
Compact PCI System
32-bit PCI bus interface, 3,3 V/5 V
galvanic isolation to AS-i
AS-i circuit 1
AS-i circuit 2
–
Program memory (EEPROM)
Individual software
RS 232
4 kb
Operating voltage
3,3 V/5 V DC and AS-i voltage
Operating current
ca. 100 mA out of 3,3 V power supply
Compact PCI Board
Accessories:
Other Fieldbuses/
Master Simulators
• As a tool for programming of the AS-i Slave ICs SAP4, SAP5,
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1783: Compact PCI Board
Article no. BW2061: PCI Board with RS 232
AS-i Control Tools
DLL drivers for: Win NT 4.0, Win 2000, Win XP
OPC Server
ca. 70 mA out of AS-i per AS-i circuit
Voltage of insulation
EMC
Ambient operating temperature
Storage temperature
AS-i cycle time per AS-i circuit
0°C .. +55°C
-25°C .. +70°C
150 μs*(Number of slaves + 2)
3.0
Price Lists
AS-i Specification
≥ 500 V
according EN 61 000-6-2, EN 61 000-6-4
AS-i Safety
ca. 300 mA out of 5 V power supply
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any dataMannheim, 29.3.11
page 191
AS-i Slave Evaluation Board
AS-i Master/Gateways/
Links/Scanner
AS-i Slave Evaluation Board
Article no. BW1423
on basis ASI-SW+
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1423
The AS-i Slave Evaluation Board on basis of the ASI-SW+ chip
by ZMD can be connected to the AS-i circuit directly and without
any additional hardware. It is a complete AS-i slave. Voltage supply is provided by the AS-i line.
The AS-i Slave Evaluation Board is suitable for experiments and
test setups and fully able to function without additional hardware. Linked to an AS-i network, it enables the AS-i Master to set
parameter outputs (PWM function) and data outputs as well as to
read data inputs.
The slave board can be simply stuck upon a bigger prototyping
board (piggy back), or via screwed terminals be attached directly
to the AS-i cable.
The ID codes and the IO code can be programmed with the help
of the A²SI/SAP4 Programming and Test Tool (Article-no.
BW1355) and the AS-i 2.1 Function and EMC-Test Masters (Article no. BW1259, BW1260)
Connections:
ASI+, ASI-
AS-i connection
Uout
DC output voltage max. 20 mA
DI2 to DI3
Data inputs
DO0 to DO1
Data outputs
FID
Periphery fault (0: no fault)
GND
Ground
Technical data
Operating current
Aprox. 20 mA (with external user application)
Operating voltage
AS-i voltage 30 V DC
Function display
Power-on LED: green
Error: red
Dimensions (L, W, H)
28 mm, 31 mm, 8 mm
Programming:
IO Code B
ID Code A
ID2 Code E
The ID codes and the IO code can be programmed with the help
of the A²SI/SAP4 Programming and Test Tool (Article no.
BW1355, see page 79) and the AS-i 2.1 Function and EMC-Test
Masters (Article no. BW1259, BW1260).
The ID codes and IO codes for the different types of slaves have
to be asked for at the AS-International Association.
The data sheet of the ASI-SW+ chip:
http://www.zmd.de/as_interface.html
Price Lists
AS-i Safety
Default setting
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 192
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Slave Evaluation Board
AS-i-Master/Gateways/
Links/Scanner
AS-i Slave Evaluation Board
Article no. BW1190
on basis A²SI
The AS-i Slave Board is suitable for experiments and test setups and fully able to function without additional hardware. Linked
to an AS-i network, it enables the AS-i Master to set parameter
outputs and data outputs as well as to read data inputs.
The slave board can be simply stuck upon a bigger prototyping
board (piggy back), or via screwed terminals be attached directly
to the AS-i cable.
The ID codes and the IO code can be programmed with the help
of the A²SI/SAP4 Programming and Test Tool (Article no.
BW1355).
Connections:
ASI+, ASI-
AS-i connection
Uout
DC output voltage max. 30 mA
U5R
5 V output voltage max. 4 mA
DI0 to DI3
Data inputs
DO0 to DO3
Data outputs
P0 to P3
Parameter in-/outputs
PST
Parameter strobe
DSR
Data strobe / reset
IRD
IR input
FID
Periphery fault (0: no fault)
GND
Ground
LED
Diagnosis LED
Technical data
Operating current
Aprox. 20 mA (with external user application)
Operating voltage
AS-i voltage 30 V DC
Function display
Power-on LED: green
Error: red
Dimensions (L, W, H)
34 mm, 31 mm, 8 mm
AS-i Safety
Programming:
Default setting
IO Code 7
ID Code F
ID2 Code 2
The ID codes and IO codes for the different types of slaves have
to be asked for at the AS-International Association.
The data sheet of the A²SI chip:
http://www.amis.com/datasheets/a2si.html
Price Lists
The ID codes and the IO code can be programmed with the help
of the A²SI/SAP4 Programming and Test Tool (Article no.
BW1355).
Other Fieldbuses/
Master Simulators
The AS-i Slave Evaluation Board on basis of the A²SI chip by
ZMD can be connected to the AS-i circuit directly and without any
additional hardware. It is a complete AS-i slave. Voltage supply is
provided by the AS-i line.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1190
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 193
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 194
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Master Simulators
Art. No.
Characteristics
P.
PROFIBUS Master Simulator
BW1131
monitoring software for PROFIBUS DP slaves,
PROFIBUS-UART, DP V0
BW1257
monitoring software for PROFIBUS DP slaves,
PROFIBUS-UART, DP V0 and DP V1
Serial PROFIBUS DP Master
BW1258
PROFIBUS Master with RS 232 interface
197
DeviceNet Master Simulator
BW1420
with USB interface
198
BW1625
as PCI board
CANopen Master Simulator
BW1453
with USB interface
199
Interface Converter
BW1094
interface converter RS 232C/RS 485 for
Bihl+Wiedemann´s AS-i master
200
Interface Converter
BW2274
USB - RS 232 interface converter
201
196
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Master Simulator
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview Master Simulators
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 195
PROFIBUS DP Master Simulator
AS-i Master/Gateways/
Links/Scanner
Monitoring Software
for PROFIBUS DP Slaves
PROFIBUS UART
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1131 DP V0
Article no. BW1257 DP V0 and DP V1 supports Log function, supports PROFIsafe
The PROFIBUS DP Master Simulator is an easy to use software
for data exchange with PROFIBUS slaves of many suppliers via
PROFIBUS DP. The PROFIBUS DP Master Simulator can
exchange data with many PROFIBUS slaves even without
GSD-file or type-file. The PROFIBUS slaves can be put into operation with the default I/O window. Input data can be read and output data can be written. Furthermore the PROFIBUS DP Master
Simulator also processes GSD-files. User parameters can be
edited and the configuration can be modified and stored. The
PROFIBUS station address can be changed as well with the
PROFIBUS DP Master Simulator, this is useful for PROFIBUS
I/O modules in protection class IP67 without addressing
switches.
The PROFIBUS DP Master Simulator offers the possibility to
scan a PROFIBUS network for connected slaves and display
them in a graphical way. In this case the PROFIBUS UART has
to be connected directly to a PROFIBUS slave. The I/O data and
the PROFIBUS user diagnosis can be displayed binary, hexdecimal and now also as ASCII code. The PROFIBUS output data
can be transmitted consistently to the PROFIBUS slave. In type
In addition, BW1257 supports a Log function as well as PROFIBUS DP V1. PROFIBUS slaves can be operated in the acyclic
mode DP V1. This is helpful especially for the commissioning of
complex field devices like drives, modular I/O systems etc.
The PROFIBUS Master Simulator consists of the software and
the PROFIBUS UART which is the ideal interface converter
between the RS 232 interface of a PC and the PROFIBUS slave.
The UART does not need any additional external power supply.
Therefore it is also suitable for mobile use with a laptop or a notebook. The PROFIBUS UART is simply inserted between the
PROFIBUS slave and RS 232 connector cable.
Beside the software "PROFIBUS DP Mastersimulator" now DLL
drivers for Windows 95/98, Windows NT as well as examples
written in C are available for download on the homepage. This offers the possibility to use the PROFIBUS UART in an application in combination with an own software. However the
PROFIBUS UART is a monitoring and commissioning tool for
PROFIBUS slaves, it is not designed to control automation processes.
Technical data of PROFIBUS UART
Type
PROFIBUS UART
Dimensions (L, W, H)
63 mm, 34 mm, 17 mm
Interfaces
Standard PC RS 232-inteface with 9-pin D-sub-plug (female)
RS 485-interface with 9-pin D-sub-plug (male)
Power supply
Powered from the RS 485 interface of the PROFIBUS slave
(5 V)
Operating current
< 60 mA
Cable length
RS 232 and RS 485: max. 2 m
Transfer rate
19200 Baud
Operating temperature
Storage temperature
0°C … +55°C
-25°C … +70°C
Requirements:
IBM compatible PC
80386 or higher
Operating system:
Windows 98,
Windows Me,
Windows 2000,
Windows XP and
Windows NT
Specification:
• Software: PROFIBUS DP
Master Simulator
• PROFIBUS UART
• D-sub-data cable
32 Bit DLL an examples (in C as
source code) are available for
download on the homepage and
are not delivered with.
Price Lists
AS-i Safety
mode it is possible to set an output as long as the mouse button
is pressed.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 196
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Serial PROFIBUS DP Master
PROFIBUS Master with
RS 232 Interface
AS-i-Master/Gateways/
Links/Scanner
PROFIBUS rope
PROFIBUS Master Class 1 and 2
Monitoring software
for PROFIBUS DP Slaves
and PROFIsafe Slaves
serial cable
(included in the package)
Article no. BW1258
The serial PROFIBUS DP Master is an easy to use software for
data exchange with PROFIBUS -and PROFIsafe slaves of many
suppliers via PROFIBUS DP. It can be processed in two modes:
1. Commissioning and test tool for PROFIBUS DP Slaves
via PROFIBUS DP V0
In this operation mode I/O data can be exchanged cyclically with
PROFIBUS slaves via PROFIBUS DP V0 Input data can be read
and output data can be written. Furthermore the serial
PROFIBUS DP Master also processes GSD-files. User
parameters can be edited and the configuration can be modified
and stored. The PROFIBUS station address can be changed as
well with the serial PROFIBUS DP Master. This is useful for
PROFIBUS I/O modules in protection class IP67 without
addressing switches.
The serial PROFIBUS DP Master offers the possibility to scan a
PROFIBUS network for connected slaves and display them in a
graphical way. In this case the serial PROFIBUS UART has to be
connected directly to a PROFIBUS slave. The I/O data and the
PROFIBUS user diagnosis can be displayed binary, hexdecimal
and now also as ASCII code. The PROFIBUS output data can be
transmitted consistently to the PROFIBUS slave. In single bit
mode it is possible to set an output as long as the mouse button
is pressed.
Beside the monitoring and putting into operation software DLL
drivers as well as examples written in C are available for
dwonload on the homepage. This offers the possibility to use the
PROFIBUS UART in an application in combination with an
own software.
2. PROFIBUS Master class 2 with PROFIBUS DP V1
functionality
In this mode the serial PROFIBUS Master works as a class 2
Master in combination with the class 1 Master in a PROFIBUS
network
Complex devices e. g. drives, modular I/O systems even
PROFIBUS PA devices can be comissioned online via
PROFIBUS DP V1. PROFIBUS PA devices need an additional
segment coupler.
Technical data of the serial PROFIBUS Master
Type
serial PROFIBUS Master
Dimensions (L, W, H)
72,0 mm, 68,5 mm, 19,5 mm
Interfaces
standard PC RS 232-interface with 9-pin
D-Sub-plug (female)
PROFIBUS interface with 9 pin D-Sub-plug (male)
Power supply
24 V DC
Operating current
< 60 mA
LED green (power)
power on
LED yellow (com)
serial interface/PROFIBUS in operation
Length of connector cables
RS 232 max. 2 m
Transfer rate RS 232
19200 Baud
Transfer rate PROFIBUS
9,6 KBaud up to 1500 KBaud
Ambient operating temperature
Storage temperature
0°C … +55°C
-25°C … +70°C
Requirements:
IBM compatible PC
80386 or higher
Operating system:
Windows 98,
Windows Me,
Windows 2000,
Windows XP and
Windows NT
Specification:
• Software: PROFIBUS DP
Master simulator
• serial PROFIBUS Master
• D-sub-transmission cord
• power supply 24 V DC
Other Fieldbuses/
Master Simulators
24V power supply
(included in the package)
AS-i Safety
Acyclic data exchange via
PROFIBUS DP V1
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Cyclic data exchange via
PROFIBUS DP V0
Price Lists
32 Bit DLL an examples (in C as
sourcecode) are available for download on
the homepage and are not delivered with.
CommDTM on request:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 197
DeviceNet Master Simulator
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Monitoring Software for DeviceNet Slaves
DeviceNet Dongle with USB Interface (Art. no. BW1420)
DeviceNet Master Simulator as PCI Board (Art. no. BW1625)
Article no. BW1420 with USB Interface
Article no. BW1625 as PCI Board
The DeviceNet Master Simulator is an easy to use software for
data exchange with DeviceNet slaves of many suppliers. The
DeviceNet Master Simulator can exchange data with the slaves
even without EDS-file. Input data can be read, output data can be
written and the DeviceNet diagnosis can be displayed. Furthermore it is possible to read and write any object independent of the
state of communication.
The DeviceNet Master Simulator offers the possibility to scan a
DeviceNet network and find all connected slaves. The I/O data is
displayed binary and hexadecimal.
Article no.
BW1420
Other Fieldbuses/
Master Simulators
Power supply
Length of connector cables
Transfer rates
Operating temperature
The DeviceNet Master Simulator consists of the software and a
DeviceNet dongle. The DeviceNet dongle is the ideal interface
converter between an USB port (the parallel interface of a PC)
and DeviceNet. The converter needs no extra power supply.
Therefore it is also suitable for mobile use with a laptop or a notebook.
PCI Board
USB interface
CAN interface with 9 pin
D-sub-plug (male)
16 Bit PCI bus interface,
CAN interface with 9 pin
D-sub-plug (male)
powered by the USB port of
the PC
powered by the PCI port of
the PC
Requirements:
- IBM compatible PC 80486 or higher
- Plug and Play Bios
Operating system:
Windows 98, Windows NT, Windows
2000, Windows Me, Windows XP
125, 250 or 500 KBaud
Specification:
Software:
- DeviceNet Master Simulator
0°C … +55°C
- DeviceNet-Dongle/PCI board
max. 2 m
-25°C … +70°C
Note:
• At the end of the DeviceNet line a bus termination (120 Ohm) has to be used.
• 32- bit DLL drivers and program examples are available for download on the homepage and are not included in delivery.
Price Lists
AS-i Safety
Storage temperature
The device identification is read out of the DeviceNet slave and
displayed together with the I/O data.
BW1625
Type
Interfaces
In single bit mode it is possible to set an output as long as the
mouse button is pressed.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 198
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
CANopen Master Simulator
The CANopen Master Simulator offers the possibility to scan a
DeviceNet network and find all connected slaves. The digital I/O
data can be displayed binary, hexadecimal and also as ASCII
code.
Analog I/O data are displayed decimal. The CANopen output
data can be transmitted consistently to the CANopen slave.
The CANopen Master Simulator consists of the software and a
CAN dongle. The CAN dongle is the ideal interface converter between the USB interface of a PC and CANopen. The converter
needs for power supply only the USB interface. Therefore it is
also suitable for mobile use with a laptop or a notebook.
Technical data of the CAN dongle
Type
CAN dongle
Interfaces
USB interface
CAN interface with 9-pin D-sub-plug (male)
Power supply
powered by the USB interface of the PC
Length of connector cables
max. 2 m
Transfer rates
5, 10, 20, 50, 100, 125, 250, 500 oder 1000 KBaud
Operating temperature
Storage temperature
0°C … +55°C
-25°C … +70°C
Requirements:
IBM compatible PC 80486 or higher
Operating system:
Windows 98, Windows NT,
Windows 2000, Windows Me,
Windows XP
Specification:
Software:
• CANopen Master Simulator
• CANopen dongle
Connections D-sub plug:
Price Lists
Accessories: D-Sub-data transmission cord for AS-i Gateways with CAN interface (art. no. BW1226, see page 185)
Other Fieldbuses/
Master Simulators
Article no. BW1453 with USB Interface
The CANopen Master Simulator is an easy to use software for
data exchange with CANopen slaves of many suppliers. The CANopen Master Simulator can exchange data with the slaves even
without EDS-file. Input data can be read, output data can be written. Furthermore it is possible to read and write any object independent of the state of communication.
AS-i Safety
CAN Dongle
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
Monitoring Software for CANopen Slaves
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 199
AS-i Master/Gateways/
Links/Scanner
Interface Converter RS 232C/RS 485
Interface converter RS 232C/RS 485
for Bihl+Wiedemann
AS-i Master
Function
The interface converter is the ideal interface between the RS 232
interface of the PC and the RS 485 interface of the AS-i Gateways. The converter is very compact and does not need any
additional external power supply. Therefore it is also suitable in
mobile use with a laptop or a notebook. The converter is simply
inserted between AS-i Gateway with RS 232 connector cable
and PC.
Only one device with RS 485 interface can be connected to the
converter.
The RS 232C/RS 485 converter can be used under different
operating systems. Using the AS-i Control Tools for Windows an
AS-i Master with RS 485 interface can be handled now just as an
AS-i Master with RS 232 interface. The RS 232C/RS 485 converter works up to transfer rates of 57600 Baud.
Technical data
Type
RS 232C/RS 485 converter
Dimensions (L, W, H)
63 mm, 54 mm, 17 mm
Interfaces
standard PC RS 232 interface with
9-pin sub-D plug (female)
RS 485 interface with 9-pin sub-D plug (male)
Power supply
gets its power from the RS 232 interface of
the PC, therefore external power supply is not
necessary. Pin 4 (DTR) has to be high.
Length of connector cables
RS 232: max. 2 m, RS 485: 2 m
Transfer rate
up to 57600 KBaud
Operating temperature
Storage temperature
0°C … +55°C
-25°C … +70°C
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no. BW1094
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 200
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
USB - RS 232 Interface Converter
AS-i-Master/Gateways/
Links/Scanner
USB - RS 232 Interface Converter
for Bihl+Wiedemann
Artikel no. BW2274
The USB - RS 232 interface converter is the ideal connection between the RS 232 interface of a device and the USB interface of
modern PCs and notebooks. It correspondents to USB 2.0
(USB 1.1) standard and can be connected directly or by using the
provided 0,80 m USB extension cord to a free USB port of the
computer. The connection to the particular device takes place via
the 9-pin Sub-D connector at the RS 232 interface
Tecnical data
Interfaces
9-pin, sub-D (RS 232)
USB 2.0 (USB 1.1) standard
Device type
serial adapter
Data Link Protocol
RS 232
USB
Maximum transfer rate
> 1 Mbps
System requirements
USB port
Windows 98/ME/2000/XP/Vista
Apple Mac OS 8.6
Extension
(included in delivery)
USB extension cord (USB - USB type A, 4-pole)
Length: 0,80 m
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Type of interface (Bus type)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Function
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 201
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 202
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Other Fieldbuses/Couplers
Coupler
PROFIBUS Option Board
Art. No.
Characteristic
BW1261
straight
BW1271
crooked
P.
204
205
BW1184
CANrho/PROFIBUS Coupler
BW1246
CAN/InterBus Coupler
BW1323
InterBus baud rate 500 KBaud / 2 MBaud, 10 words
BW2504
InterBus baud rate 500 KBaud / 2 MBaud, 1-12 words
206
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
CAN/PROFIBUS Coupler
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview other Fieldbuses/Couplers
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 203
AS-i Master/Gateways/
Links/Scanner
PROFIBUS Option Board
How to interface your
device to a PROFIBUS network?
The simplest way:
PROFIBUS Option Board
straight
Rugged and quick
mounting
Coupling via serial
interface (TTL-level)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
crooked
Article no. BW1261: PROFIBUS Option Board (straight)
Article no. BW1271: PROFIBUS Option Board (crooked)
How to interface your device to a PROFIBUS network? With the
PROFIBUS Option Board.
The PROFIBUS Option Board is an embedded PROFIBUS slave
interface for manufacturers of industrial automation products. It
features an inexpensive PROFIBUS module with a serial interface to
the host product.
The board is designed for rugged and quick mounting. The D-Sub
connector for PROFIBUS can be delivered crooked or straight
according to requirements of installation.
The serial connection to the host device is made flexibly via a 14 pin
connector.
With the help of the PROFIBUS Option Board any devices can be
offered with PROFIBUS interface without high development
expenses.
The PROFIBUS Option Board is mounted in combination with the
host hardware inside the housing of the host product.
The PROFIBUS Option Board provides the PROFIBUS DP slave
interface between a host product with a serial interface and the
PROFIBUS network.
For the use there is no need of any knowledge about PROFIBUS.
The PROFIBUS Option board is served by the host product via the
serial interface with a very simple serial telegram.
Other Fieldbuses/
Master Simulators
Pining of 14-pin connector
Article Nr.
Connection
PROFIBUS interface
PROFIBUS baud rates
AS-i Safety
DP funkcions
Connection to the host
Serial baud rates
Transfer format
Signal level of the serial interface
CTS
3
TXD
4
RXD
9
+5V supply
10, 11
GND
others
NC.
BW1271
PROFIBUS: optional D-Sub 9-pin 180° or 90°
serial interface: pinhead
according to DIN 19 245 part 1-3
9,6 KBaud to 12000 KBaud, automatic recognition
Imaging of the serial data as I/O data of the PROFIBUS
Complete diagnosis and configuration via DP-Master
14 pin connector, 2 row type, 2,54 mm pitch, optional 180° or 90°
19,2 KBaud/57,6 KBaud
8N1
0 V, +5 V (not ±12 V)
Operating current
max. 400 mA incl. PROFIBUS bus terminal
Operating voltage
+5 V, ±5%
Voltage of insulation
EMC directions
Operating temperature
Price Lists
BW1261
2
Storage temperature
Dimensions (L /W /H)
Connections
≥ 500 V
EN 50 082,, EN 50 081
0°C … +55°C
-25°C … +85°C
133,4 /41,9 / 8
PROFIBUS: optional D-Sub 9-pin 180° or 90°
serial interface: pinhead
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 204
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
CAN/PROFIBUS Coupler
Easy data exchange
between CAN and PROFIBUS
via the internal coupling
Article no. BW1184: CANrho/PROFIBUS Coupler
Article no. BW1246: CAN/PROFIBUS Coupler
The CAN/PROFIBUS Coupler is the easiest solution to exchange
data between CAN and PROFIBUS.
In big applications is often a need to exchange data between a
control of a CAN network and another PLC, e. g. to report the
process status. This problem was solved in the past with the help
of normal I/O modules, with the inputs of the control of the CAN
network connected to the outputs of the other PLC and vice
versa. With the use of the CAN/PROFIBUS Coupler to solve this
problem the installation costs as well as the components costs
can be reduced.
a PROFIBUS slave with n bytes input data and 8 bytes output
data in one housing. The outputs of one slave are connected to
respective inputs of the other slave and vice versa (output data
byte 1 of the CAN slave with input data byte 1 of the PROFIBUS
slave and vice versa, etc.).
There is a galvanic isolation between CAN and PROFIBUS.
A seven digit display can be used for commissioning and diagnosis.
As long as one of both slaves does not exchange data the other
slave reads on each input a 0 as default.
The CAN/PROFIBUS Coupler consists of a CAN slave with n
bytes (8, 16 or 24 bytes) input data and n bytes output data and
PROFIBUS interface
Baud rates
DP functions
CAN baud rates
Display
BW1246
PROFIBUS: D-Sub 9-pin
CAN: 4-pin COMBICON plug
according to DIN 19 245 part 1-3
9,6 KBaud to 12000 KBaud,
automatic recognition
Imaging of the CAN Data as I/O data of the PROFIBUS
Complete diagnosis and configuration via DP master
125 KBaud, 250 KBaud, 500 KBaud, 1 MBaud
< 120 mA at 24 V
Operating voltage
24 V DC
EMC directions
Operating temperature
Storage temperature
Housing
≥ 500 V
EN 50 082,
EN 50 081
0°C … +55°C
-25°C … +85°C
Housing for DIN-rail mounting
Protection category (DIN 40 050)
Housing IP20
Dimensions (L /W /H)
100 /25 /120
120 g
Price Lists
Weight
Terminal assignment:
seven digit
Operating current
Voltage of insulation
CAN/PROFIBUS connections
Other Fieldbuses/
Master Simulators
Connections
BW1184
AS-i Safety
Article no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
Connection of a CAN network
and a PROFIBUS network
via integrated interfaces
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 205
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
CAN/InterBus Coupler
Connection of a CAN network
and a InterBus network
via integrated interfaces
Easy data exchange
between CAN and InterBus
via the internal coupling
Article no. BW1323: InterBus baud rate 500 KBaud / 2 MBaud, 10 words
Article no. BW2504: InterBus baud rate 500 KBaud / 2 MBaud, 1-12 words
The CAN/InterBus Coupler is the easiest solution to exchange
data between CAN and InterBus.
In big applications is often a need to exchange data between the
robot control and another PLC, e. g. to report the process status.
This problem was solved in the past with the help of normal I/O
modules, with the inputs of the robot control connected to the outputs of the other PLC and vice versa. With the use of the
CAN/InterBus coupler to solve this problem the installation costs
as well as the components costs can be reduced.
Article no.
Connections
There is a galvanic isolation between CAN and InterBus.
The device has got 6 LEDs for commissioning and diagnosis.
As long as one of both slaves does not exchange data the other
slave reads on each input a 0 as default.
BW1323
BW2504
CAN: D-Sub 9-pin
InterBus: Fiber optic interface
InterBus interface
on basis SUPI 3 OPC
Baud rates
500 KBaud / 2 MBaud
Functions
imaging of the CAN Data as I/O data of the InterBus
CAN baud rates
Other Fieldbuses/
Master Simulators
The CAN/InterBus coupler consists of a CAN slave with input and
output data and an InterBus slave with input and output data in
one housing (data width see table). The outputs of one slave are
connected to respective inputs of the other slave and vice versa.
Data width
Display
20 kBaud, 125 kBaud, 250 kBaud, 500 kBaud
3 words
1-12 words
6 LEDs
Operating current
< 100 mA at 24 V
Operating voltage
24 V DC
Voltage of insulation
EMC directions
Operating temperature
Storage temperature
Housing
≥ 500 V
EN 50 082, EN 50 081
0°C … +55°C
-25°C … +85°C
housing for DIN-rail mounting
Protection category (DIN 40 050)
housing IP00
Dimensions (L /W /H in mm)
110 /105 /60
200 g
Price Lists
AS-i Safety
Weight
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 206
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety
P.
AS-i 3.0 PROFIBUS Gateway
BWU2001
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
217
BWU2002
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
219
AS-i 3.0 PROFIBUS Gateway
BWU2202
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
Ethernet diagnostics interface
221
AS-i 3.0 PROFIBUS Gateway
BWU2003
with integrated Safety Monitor in one housing
1 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
223
BWU2004
1 AS-i-Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
225
BWU2187
1 AS-i Master, 16 release circuits,
2 indepentent output switching elements,
RS 232 diagnostics interface
227
BWU2188
1 AS-i Master, 16 release circuits,
power supply decoupling unit,
2 indepentent output switching elements,
RS 232 diagnostics interface
229
AS-i 3.0 PROFIBUS Gateway
BWU2206
with integrated Safety Monitor in one housing
1 AS-i Master, 16 release circuits,
power supply decoupling unit,
2 indepentent output switching elements,
Ethernet diagnostics interface
231
BWU2330
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
233
BWU2237
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
235
BWU2307
1 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
237
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway
BWU2317
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
239
BWU2267
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
241
BWU2273
1 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
243
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Characteristics
Other Fieldbuses/
Master Simulators
Art. No.
AS-i Safety
Module
Price Lists
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Safety
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 207
AS-i Safety
AS-i Master/Gateways/
Links/Scanner
Housing
Module
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Characteristics
P.
AS-i 3.0 EtherCAT Gateway
BWU2281
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
245
BWU2338
1 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
247
BWU2479
1 AS-i Master, PROFIsafe for 1 AS-i network,
RS 232 diagnostics interface
249
BWU2434
1 AS-i Master, PROFIsafe for 1 AS-i network,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
251
BWU2214
2 AS-i Master, PROFIsafe for 2 AS-i networks,
4 indepentent output switching elements,
RS 232 diagnostics interface
253
BWU2215
2 AS-i Master, PROFIsafe for 2 AS-i networks,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
255
BWU2421
2 AS-i Master, PROFIsafe for 2 AS-i networks,
4 indepentent output switching elements,
RS 232 diagnostics interface
257
BWU2383
2 AS-i Master, PROFIsafe for 2 AS-i networks,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
259
AS-i Safety Monitor in stainless steel,
generation II
BWU2205
AS-i Safety Monitor in Stainless Steel, Generation II, 262
16 release circuits,
2 indepentent output switching elements,
Ethernet diagnostics interface
AS-i Safety Monitor in stainless steel,
generation II
BWU2000
16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
264
BWU2186
16 release circuits,
2 indepentent output switching elements,
RS 232 diagnostics interface
266
BW2441
AS-i Master disengageable, 8 release circuits,
8 / 4 safe inputs and 2 (4) electronical safe outputs,
USB interface
268
BW2557
8 release circuits, 8 / 4 safe inputs and
2 (4) electronical safe outputs, USB interface
AS-i 3.0 Gateway PROFIsafe via PROFIBUS
Other Fieldbuses/
Master Simulators
Art. No.
AS-i 3.0 Gateway PROFIsafe via PROFINET
AS-i Safety
Safety Basic Monitor
BW2512
270
Price Lists
Safety Basis Monitor Starter Kit
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 208
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety
P.
BW1764
advanced monitor, 1 release circuit, 40 ms
BW1765
advanced monitor, 2 release circuits, 40 ms
271
AS-i Speed Monitor
BW2427
2 indepentent axis, chip card
Speed Monitor head unit and Speed Monitor
for 2 axis
BW2538
prewired complet set, parameterization of the speed 276
275
via USB, monitoring up to 40 axis with expansion
modules possible
Connecting cable for Speed Monitor
Adapter for Speed Monitor
AS-i Safety In-/Output Module
connector-ferrule
connector-ferrule
BW2494
plug-plug
277
BW2497
AMP Mini-I/O connector for e.g. Elau MC-4
BW2499
AMP Mini-I/O connector for e.g. B+R Acopos Sin Cos
Interface
278
BW2314
AS-i Safety 4I/2O Module, 8 / 4 safety inputs and
2 (4) electronical safety outputs
279
BWU2236
AS-i Safety Relay In-/Output Modul, with diagnostic
slave, 1 EDM- and 2 / 1 safety inputs
281
BWU2045
relay output module with diagnostic slave
and 1 EDM input
285
BWU2173
output module with diagnostic slave, 1 EDM input,
3I and 2O
289
Price Lists
AS-i Safety Output Module
BW2476
BW2477
AS-i-Master/Gateways/
Links/Scanner
Characteristics
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Safety Monitor
Art. No.
Other Fieldbuses/
Master Simulators
Module
AS-i Safety
Housing
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 209
AS-i Safety
Module
Art. No.
Characteristics
AS-i Safety Input Module (M12)
BWU2284
AS-i Safety Input Module, 2 / 1 safety inputs
(2 channels) for floating contacts,
protection category IP67
293
BWU2270
AS-i Safety Input Module, 2 / 1 safety inputs
(2 channels) for optoelectronic protective devices,
protection category IP67
295
AS-i Safety Input Module
BWU1939
2 / 1 safety inputs (2 channels) for floating contacts,
protection category IP20
297
Emergency stop and reception
BW2527
emergency stop button with plug-in-shoe connection 298
AS-i Safety OEM Slave
BW2426
with 2 standard outputs, supply out of AS-i,
LED display, potted, with connection line
BW2521
with 2 standard outputs, supply out of AS-i,
LED display, potted, with pin connection
AS-i Substructure Module in IP67
BW1896
with screw terminals
BW1751
with plug-in screw terminals
BW1801
with wiring pins
BW1934
no connection
BW2349
for 4-channel module in 45 mm-housing
BW2350
for 4-channel module in 45 mm-housing, centerline
spacing CNOMO
BW2351
for 8-channel module in 60 mm-housing, centerline
spacing CNOMO
P.
299
300
301
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Housing
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 210
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety
Programming software ASIMON and
AS-i Control Tools
Programming software ASIMON
Characteristics
P.
BW2071
with serial cable for AS-i Master/Monitor in stainless 304
steel
BW2501
for Safety Monitors and AS-i Masters
BW2145
with serial cable for AS-i Master/Monitor in stainless
steel
BW1770
with cable BW1771 and BW1772 only for use with the
Safety Monitors BW1764 and BW1765
BW2222
memory capacitiy 128 kbyte
BW2079
memory capacitiy 32 kbyte
305
Serial cable
BW1575
for AS-i Masters and AS-i Monitors in stainless steel 304
USB connector cable
BW2530
for Safety Basic Monitor
304
Interface cable
BW1771
for connection of the Safety Monitor to a PC
304
Interface cable
BW1772
for connection of 2 Safety Monitors
304
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Chipcard
Art. No.
AS-i-Master/Gateways/
Links/Scanner
Module
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Housing
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 211
AS-i Master/Gateways/
Links/Scanner
AS-i Safety
AS-i Safety at Work:
AS-i safety monitors,
AS-i gateways with integrated safety monitor
and AS-i safety slaves
for monitoring
Safety at Work networks
In addition to the AS-i safety monitors, Bihl+Wiedemann offers Gateways with integrated safety monitor and AS-i Safety Slaves. This
provides the user with the full range of products for monitoring AS-i Safety at Work networks as well.
AS-i coupling network
BW2188
r
e
S
ro
le
U
e
tiv
ab
B
er
i
od
FI
ig
jm
er
en
i ac
S-
O
w
nf
g
A
S-
po
A
1.13 0 V 24 V 2.13
2.Y2 + 2.Y1 +
Aux
Aux
AS-i Safety
AS-i Safety
Integrated
Integrated
1.Y1
1.Y1
1.Y2
1.Y2
2.Y1
2.Y1
2.Y2
2.Y2
K1
K1
ESC
Service
+ASI 1
+ 1.Y1 + 1.Y2
1.14 3.14 4.14 2.14
Set
+ASI 2
K4
Mode
ESC
Service
ASI
+PWR
+ASI 1
+ASI 1
OK
Analog In
Adr. 3
Analog In
Adr. 10
+ 1.Y1 + 1.Y2
1.14 3.14 4.14 2.14
Set
+ASI 2
ASI
+PWR
AS-i 1
Safety In
Adr. 1
Coupling slave Adr. 7
Emergency stop circuit 2
K3
AS-i 2
+ASI 1
OK
K2
Coupling slave Adr. 2
Emergency stop circuit 1
K4
AS-i 2
K2
K3
Mode
Coupling slave Adr. 6
Creep speed
pr
U
co
PR
e
S
ro
le
e
U
tiv
ab
B
er
i
od
FI
ig
er
en
i ac
S-
O
w
nf
g
jm
A
S-
po
A
pr
co
pr
U
PR
1.13 0 V 24 V 2.13
2.Y2 + 2.Y1 +
AS-i 1
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
chip card
RS 232
Coupling slave Adr. 1
Light grid 1
r
chip card
RS 232
pr
BW2002
Analog In
Adr. 4
Analog In
Adr. 11
Safety In
Adr. 6
Other Fieldbuses/
Master Simulators
OEM Safety
Adr. 21
OEM 3O
Adr. 22A
OEM 3O
Adr. 23A
Safety In
Adr. 12
Safety In
Adr. 13
OEM Safety
Adr. 24
OEM 4I/4O
Adr. 26
OEM 2I/2O
Adr. 27
Safety Out
Adr. 4/7B
Safety Out
Adr. 2/7A
Safety monitors
1. 1 program for 2 Safety at Work networks
2. Up to 31 Safety at Work networks can be easily linked
together
3. 16 release circuits enable fast, reliable and highly simplified
and differentiated system response
4. Expanded programming allows up to 256 functions without
increasing the response time
5. Linked networks can be started together
6. Safe Safety at Work outputs allow switching – even at great
distances from the Monitor – without additional wiring
7. The use of memory cards greatly simplifies both program
changing when units are replaced and programming of the
Monitor using ASIMON software
8. The expanded AS-i diagnostics of the Bihl+Wiedemann AS-i
Master, including duplicate address detection, ground fault
monitor, EMC monitor, error counter etc. are of course fully
integrated
Price Lists
AS-i Safety
Using the newest generation Safety Monitors allows 2 Safety at Work networks and up to 16 release circuits to be monitored. The user
is provided with comprehensive detailed diagnostics and system status information in plain text on the Monitor’s display. In addition to
the high SIL 3/Cat. 4 safety level, the monitors offer additional features beyond the standard:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 212
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety
One Bihl+Wiedemann Safety Monitor monitors two networks simultaneously and can emulate multiple slaves at the same time. This
enables two different configurations:
Standard case: 2 Safety at Work networks
SPS
Field level
•
•
•
•
Just 1 instead of 2 monitor programs
Fast response
No additional hardware
Combination unit with double master saves costs, space and installation expense
Sensor/Actuator level
AS-i Safety Monitor
AS-i 1
The large network: 3 Safety at Work networks
AS-i 2
Multiple local Safety at Work networks are each monitored by 1 Multimonitor which is at the same time a node in a higher-level coupling
network. There it is on one hand a Monitor, while on the other hand it internally emulates virtual slaves, through which it exchanges its
own release circuits with those of the other monitors (see figure below):
pow
er
PR
OF
con IBU
fig S
err
U
AS
or
-i
AS
-i
act
prg
ive
ena
prj
ble
mo
de
•
Coupling network
Monitor
with virtual
slaves
1, 2, 3
Monitor
with virtual
slaves
4, 5... 17
Monitor
with virtual
slaves
18,19..31
Local network 2
Local network 1
• Up to 31 local networks are networked in a safety
configuration
• Up to 16 virtual slaves per monitor
• Up to 31 virtual slaves in the coupled network
• Fast, bi-directional coupling of all local network with each
other
• Very large networks with differentiated responses are possible
without a safety controller or master
Local network 3
AS-i Gateways with integrated AS-I Safety Monitor
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Two equal-priority Safety at Work networks are monitored by just one Multimonitor:
AS-i-Master/Gateways/
Links/Scanner
Configuration example: Safe networking of up to 21 Safety at Work networks
Monitor
with
2 AS-i circuits
AS-i 2
AS-i 1
AS-i 2
=
AS-i 1
AS-i 2
AS-i 1
+
Gateway with
integrated Safety Monitor
with 2 AS-i circuits
1. The advantages of the Safety Monitor (see above) and all
the properties of an AS-i 3.0 Gateway including expanded
local diagnostics, graphic display etc. are combined in one
unit.
2. Available with and without power supply decoupling.
3. Ideally matched to all Bihl+Wiedemann power supplies.
4. Save costs, installation effort and control cabinet space:
e.g. replaces the combination "Double Master with power
supply decoupling + Multimonitor" together with a standard
power supply (i.e. 2 devices) for a total of 6 individual units
(2 Masters, 2 Monitors, 2 AS-i power supplies).
5. Coupling of Gateway and Safety Monitor to the Safety at
Work network.
6. No AS-i address is occupied for the Safety Monitor diagnostics.
The product series of AS-i Gateways with integrated Safety Monitors is being continually expanded with additional field buses.
AS-i Safety Slaves
In addition to Safety Monitors AS-i gateways with integrated Safety Monitor, Bihl+Wiedemann also offers a wide range of AS-i Safety
Slaves. For example, AS-i safety relay modules and various AS-i Safety OEM Slaves are available. These are also SIL 3/Cat. 4 approved.
The AS-i Safety OEM Slaves currently offer the possibility of driving 2 safe switching contacts, e.g. signal lamps, over the AS-i safety network.
Price Lists
The AS-i Safety Relay Output Module with conventional
4 inputs combines one AS-i Safety Relay Output with 4
inputs (1 EDM + 3 conventional (AB slave)) in one unit.
AS-i Safety
Gateway
with
2 AS-i circuits
Other Fieldbuses/
Master Simulators
AS-i Gateways with integrated Safety Monitors combine an AS-i Gateway (e.g. PROFIBUS) with the new Safety Monitors in one unit
to couple the Monitor and Gateway to the Safety at Work network, enabling a broad range of safety applications quickly and easily.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 213
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 214
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety with integrated Safety Monitor
P.
AS-i 3.0 PROFIBUS Gateway
BWU2001
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
217
BWU2002
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
219
AS-i 3.0 PROFIBUS Gateway
BWU2202
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
Ethernet diagnostics interface
221
AS-i 3.0 PROFIBUS Gateway
BWU2003
with integrated Safety Monitor in one housing
1 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
223
BWU2004
1 AS-i-Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
225
BWU2187
1 AS-i Master, 16 release circuits,
2 indepentent output switching elements,
RS 232 diagnostics interface
227
BWU2188
1 AS-i Master, 16 release circuits,
power supply decoupling unit,
2 indepentent output switching elements,
RS 232 diagnostics interface
229
AS-i 3.0 PROFIBUS Gateway
BWU2206
with integrated Safety Monitor in one housing
1 AS-i Master, 16 release circuits,
power supply decoupling unit,
2 indepentent output switching elements,
Ethernet diagnostics interface
231
BWU2330
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
233
BWU2237
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
235
BWU2307
1 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
237
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway
BWU2317
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
239
BWU2267
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
241
BWU2273
1 AS-i Master, 16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
243
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Characteristics
Other Fieldbuses/
Master Simulators
Art. No.
AS-i Safety
Module
Price Lists
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Safety with integrated Safety Monitor
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 215
AS-i Safety with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Housing
Module
Characteristics
P.
AS-i 3.0 EtherCAT Gateway
BWU2281
with integrated Safety Monitor in one housing
2 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
245
BWU2338
1 AS-i Master, 16 release circuits,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
247
BWU2479
1 AS-i Master, PROFIsafe for 1 AS-i network,
RS 232 diagnostics interface
249
BWU2434
1 AS-i Master, PROFIsafe for 1 AS-i network,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
251
BWU2214
2 AS-i Master, PROFIsafe for 2 AS-i networks,
4 indepentent output switching elements,
RS 232 diagnostics interface
253
BWU2215
2 AS-i Master, PROFIsafe for 2 AS-i networks,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
255
BWU2421
2 AS-i Master, PROFIsafe for 2 AS-i networks,
4 indepentent output switching elements, RS 232
diagnostics interface
257
BWU2383
2 AS-i Master, PROFIsafe for 2 AS-i networks,
power supply decoupling unit,
4 indepentent output switching elements,
RS 232 diagnostics interface
259
AS-i 3.0 Gateway PROFIsafe via PROFIBUS
AS-i 3.0 Gateway PROFIsafe via PROFINET
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art. No.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 216
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, PROFIBUS-Slave
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1568!
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
Monitor configuration can be „arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article no.
BWU2001
PROFIBUS interface
Baud rates
DP functions
according to DIN 19 245, part 3
9,6 kBaud up to 12 000 kBaud, automatic recognition
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
RS 232
150 μs * (number of slaves + 2)
Serial interface
AS-i cycle time
Safety monitor
Release circuits
Start delay
Respond delay
Inputs:
4 x EDM/Start
Outputs:
4 x output switching elements
Card slot
Displays
LCD
LED power
LED PROFIBUS
LED config error
LED U AS-i
LED AS-i active
LED prg enable
LED prj mode
LED AUX
4 x LED EDM/Start
US
4
< 10 s
< 40 ms
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
chip card for storage of configuration data
indication of slave adresses and error messages
power on
PROFIBUS master recognized
configuration error
AS-i voltage OK
AS-i normal operation active
automatic addresses programming enabled
configuration mode active
auxiliary power
state of inputs:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 217
Other Fieldbuses/
Master Simulators
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
AS-i Safety
Safe AS-i outputs are supported on both AS-i networks
Price Lists
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article no.
BWU2001
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
30 V, 9 W
≥ 500 V
Operating voltage
Voltage of insulation
UL-specifications (UL508)
External Protection
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
in general
cTÜVus
Standards
Housing
Ambient operating temperature
Storage temperature
Dimensions (L / W / H in mm)
Protection category IEC 60 529
Tolerable loading referring to impacts
and vibrations
Weight
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
The devices BWU2001 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, PL e
AS-i master housing in stainless steel
0°C … +55°C
-25°C … +85°C
120 / 100 / 96
IP20
according to EN 61 131-2
800 g
Safety Monitor block diagram:
Connections:
Gateway + Safety Monitor
3.14
0V
1.13
2.Y2
4.14
1.13
0V
+4
24 V 2.13
+3
2.Y1
output switching elements
EDM/START inputs
1.14
2.14
2.13
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
PROFIBUS
Other Fieldbuses/
Master Simulators
24 V
AS-i Safety
Sicherheitsmonitor
(Safety Monitor)
+
-
+
+ASI 1–
ASI 1 +PWR- (max. 8A)
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
-
+
-
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
output switching elements
+ ASI 2 –
ASI
+ 2 +PWR- (max. 8A)
Accessories:
• Software ASIMON 3 G2 and AS-i Control-Tools with serial cable for AS-i Master/monitors in stainless steel (art. no. BW2071)
Price Lists
• Serial PROFIBUS-Master (art. no. BW1258)
• PROFIBUS-DP-Master simulator (art. no. BW1257)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 218
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, PROFIBUS-Slave
• Version “1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks“
• Full functional range of
Bihl+Wiedemann PROFIBUS-Gateways BWU1569!
• Enhanced functional range
of Bihl+Wiedemann Sicherheitsmonitors BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
Safe AS-i outputs are supported on both AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor programm size not restricted
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article number
BWU2002
PROFIBUS interface
according to DIN 19 245, part 3
US
Baud rates
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i-Slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety Monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max.contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Other Fieldbuses/
Master Simulators
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
chip card for storage of configuration data
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 219
Price Lists
Card slot
Displays
AS-i Safety
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
BWU2002
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply, approx 300 mA out of AS-i network
Operating voltages
30 V, 9 W
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2002 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts and vibrations according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections:
24 V
3.14
Other Fieldbuses/
Master Simulators
0V
Gateway + Safety Monitor
1.13
2.Y2
4.14
1.13
0V
+4
24 V 2.13
+3
2.Y1
output switching elements
EDM/START inputs
1.14
2.14
2.13
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
PROFIBUS
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article number
Sicherheitsmonitor
(Safety Monitor)
+
-
+
-
+ASI 1–
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
AS-i Safety
+ASI 1–
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+ ASI 2 –
+
AS-i +PWR- (max. 8A)
EDM/START inputs
output switching elements
Accessories:
• Software ASIMON 3 G2 and AS-i-Control-Tools with serial cable for AS-i Master/monitors in stainless steel (art. no. BW2071)
• Serial PROFIBUS-Master (art. no. BW1258, see also page 197)
Price Lists
• PROFIBUS-DP-Master simulator (art. no. BW1257, see also page 196)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 220
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, PROFIBUS Slave
• Version “1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks“
• Ethernet diagnostics interface
• Integrated power supply decoupling unit
• Full functional range of
Bihl+Wiedemann PROFIBUS Gateway BWU1777
• Enhanced functional range
Bihl+Wiedemann Safety Monitor BWU2000
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
Monitor programm size not restricted
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article number
BWU2202
PROFIBUS interface
according to DIN 19 245, part 3
Baud rates
9,6 KBaud up to 12000 KBaud, automatic recognition
DP functions
imaging of the AS-i-Slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Diagnostics interface
Ethernet
AS-i cycle time
150 ms * (number of slaves + 2)
US
Safety Monitor
Release circuits
16
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max.contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
LED AUX
24 V for semiconductor outputs present
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 221
Other Fieldbuses/
Master Simulators
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
AS-i Safety
Safe AS-i outputs are supported on both AS-i networks
Price Lists
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
Article number
BWU2202
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Operating current
master power supply, approx 300 mA out of AS-i network
Operating voltage
AS-i voltage 30 V DC
Voltage of insulation
≥ 500 V
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2202 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts
and vibrations
according to EN 61 131-2
Weight
800 g
Other Fieldbuses/
Master Simulators
Safety Monitor block diagram:
Connections:
Gateway + Safety Monitor
24 V
3.14
0V
1.13
2.Y2
4.14
1.13
0V
+4
24 V 2.13
+3
2.Y1
output switching elements
EDM/START inputs
1.14
2.14
2.13
Freigabe
(Release)
AS-i Safety
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
PROFIBUS
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
Sicherheitsmonitor
(Safety Monitor)
+
-
+
-
+ASI 1–
+ASI 1–
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+ ASI 2 –
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
output switsching elements
+
AS-i +PWR- (max. 8A)
Price Lists
Accessoiries:
• Software ASIMON 3 G2 and AS-i Control Tools (art. no. BW2501)
• Serial PROFIBUS-Master (art. no. BW1258, see also page 197)
• PROFIBUS-DP-Master simulator (art. no. BW1257, see also page 196)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 222
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
1 AS-i 3.0 Single Master, PROFIBUS Slave
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1567!
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration!
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor configuration can be „arbitrarily large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
BWU2003
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 µs)
Output:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 223
Other Fieldbuses/
Master Simulators
according to DIN 19 245, part 3
Baud rates
AS-i Safety
PROFIBUS interface
Price Lists
Article number
US
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2003
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2003 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN 954-1, category 4
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts
and vibrations
according to EN 61 131-2
Weight
800 g
Other Fieldbuses/
Master Simulators
Safety Monitor block diagram:
Connections:
24 V
3.14
0V
1.13
2.Y2
4.14
1.13
24 V 2.13
+4
2.Y1
+3
output switching elements
EDM/START inputs
1.14
2.14
2.13
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
+
-
+
-
+ASI 1–
AS-i Safety
0V
PROFIBUS
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
+ASI 1–
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
ASI 1 +PWR– (max. 8A)
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
output switching elements
+
+ASI 2- / 24V 0V
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/monitors in stainless steel (art. no. BW2071)
• Serial PROFIBUS Master (art. no. BW1258, see also page 197)
Price Lists
• PROFIBUS DP Master Simulator (art. no. BW1257, see also page 196)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 224
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
1 AS-i 3.0 Single Master, PROFIBUS-Slave
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Version "1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks"
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1891!
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor configuration can be „arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article number
BWU2004
PROFIBUS interface
according to DIN 19 245, part 3
Baud rates
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
US
Safety Monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
Max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Display
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 225
Other Fieldbuses/
Master Simulators
Safe AS-i outputs are supported on both AS-i networks
AS-i Safety
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
Price Lists
16 release circuits
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2004
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2004 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category (IEC 60 529)
IP20
Tolerable loading referring to
impacts and vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections:
24 V
3.14
0V
Gateway + Safety Monitor
1.13
2.Y2
4.14
1.13
0V
24 V 2.13
+4
2.Y1
+3
output switching elements
EDM/Start inputs
1.14
2.14
2.13
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
PROFIBUS
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
AS-i Safety
Sicherheitsmonitor
(Safety Monitor)
+
-
+
-
+ASI 1–
+ASI 1–
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+ ASI 2 –
+
-
+1
1.14
1.Y1
3.14
+2
4.14
1.Y2
2.14
EDM/Start inputs
output switching elements
+
ASI
1 +PWR- (max. 4A)
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/monitor in stainless steel (art. no. BW2071)
Price Lists
• Serial PROFIBUS Master (art. no. BW1258)
• PROFIBUS DP Master Simulator (art. no. BW1257)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 226
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS-DP Gateway/Link
with integrated Safety Monitor
Redundant power supply out of AS-i:
all fundamental functions of the device remain available
even in case of power failure in one of the two AS-i networks
Gateway + Safety Monitor in one housing:
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1567!
• Enhanced funcional range
of Bihl+Wiedemann Safety Monitor BWU2186!
BWU2187
supports safe AS-i outputs (e.g. BW2045, ...)
PROFIBUS interface
according to DIN 19 245, part 3
Baud rates
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs*(number of slaves + 2)
US
Safety Monitor
Release circuits
2-channel
Start delay
< 10 s
Respond delay
< 40 ms
Inputs
2 x EDM / inputs of external device monitoring circuits 1 and 2
2 x Start / start inputs, output circuits 1 and 2
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs
4 x output switching elements, output circuits 1 and 2
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Display
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1
(approx. 70 mA ... 300 mA)
max. 200 mA out of AS-i circuit 2
(approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
Other Fieldbuses/
Master Simulators
C
AS-i Safety
Chip card for storage of configuration data
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
1 AS-i 3.0 Master PROFIBUS Slave
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 227
Price Lists
UL-specifications (UL508)
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
supports safe AS-i outputs (e.g. BW2045, ...)
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
CTÜVUS
The device BWU2187 from Bihl+Wiedemann GmbH was safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL3
EN 954-1, categorie 4
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts
and vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections:
1.13
2.Y2
1.13
1.14
1.23
1.24
2.14
2.13
2.23
2.13
2.Y1
2.23
+3
output switching elements
EDM inputs
START inputs
2.24
Freigabe
(Release)
Other Fieldbuses/
Master Simulators
1.23
+4
PROFIBUS
AS-i Master/Gateways/
Links/Scanner
BWU2187
Freigabe
(Release)
+
Freigabe
(Release)
-
+
-
Freigabe
(Release)
+ASI 1-
Sicherheitsmonitor
(Safety Monitor)
Eingänge
(Inputs)
1.Y1 (EDM 1)
2.Y1 (EDM 2)
1.Y2 (Start 1)
2.Y2 (Start 2)
+
-
+1
1.14
1.Y1
1.24
+ 2 1.Y2
2.14 2.24
+ASI 1ASI 1 +PWR- (max. 8A)
+
+ASI 2- / 24V 0V
EDM inputs
START inputs
output switching elements
Accessories:
• Software ASIMON 3 G2 and „AS-i Control Tools" with serial cable for AS-i Master/monitors in stainless steel (art. no. BW2071)
• PROFIBUS DP Master Simulator (art. no. BW1257, see also page 196)
Price Lists
AS-i Safety
• Serial PROFIBUS Master (art. no. BW1258, see also page 197)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 228
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS-DP Gateway/Link with integrated
Safety Monitor/Power Supply Decoupling Unit
Redundant power supply out of AS-i:
all fundamental functions of the device remain available even
in case of power failure in one of the two AS-i networks
Gateway + Safety Monitor in one housing:
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1567!
• Enhanced funcional range
of Bihl+Wiedemann Safety Monitor BWU2186!
1 AS-i 3.0 Master PROFIBUS Slave
Chip card for storage of configuration data
C
Article no.
PROFIBUS interface
US
BWU2188
according to DIN 19 245, part 3
Baud rates
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety Monitor
Release circuit
2-channel
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
2 x EDM: inputs of external device monitoring circuits 1 and 2
2 x START: start inputs, output circuits 1 and 2
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements, output circuits 1 and 2
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Other Fieldbuses/
Master Simulators
Supports safe AS-i outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
• Compatible with the wide range of Bihl+Wiedemann power supplies
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
Buttons
4
AS-i Safety
Displays
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 229
Price Lists
Electrical data
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
BWU2188
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
In general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The device BWU2188 from Bihl+Wiedemann GmbH was safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN 954-1, category 4
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category (IEC 60 529)
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety Monitor block diagram:
Connections:
Gateway + Safety Monitor
1.13
1.14
1.23
1.24
2.14
2.23
Other Fieldbuses/
Master Simulators
1.23
+4
2.13
2.Y1
2.23
+3
EDM inputs
START inputs
output switching elements
2.13
2.24
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
+
-
+
-
+ASI–
Sicherheitsmonitor
(Safety Monitor)
Eingänge
(Inputs)
1.Y1 (EDM 1)
2.Y1 (EDM 2)
1.Y2 (Start 1)
2.Y2 (Start 2)
+
-
+1
1.14
1.Y1
1.24
+ 2 1.Y2
2.14 2.24
+ASI–
+ ASI S –
+
AS-i +PWR- (max. 4A)
EDM inputs
START inputs
output switching elements
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/monitor in stainless steel (art. no. BW2071)
• Serial PROFIBUS Master (art. no. BW1258, see also page 197)
• PROFIBUS DP Master Simulator (art. no. BW1257, see also page 196)
Price Lists
AS-i Safety
1.13
2.Y2
PROFIBUS
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article no.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 230
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS-DP Gateway/Link with integrated
Safety Monitor/Power Supply Decoupling Unit and
Ethernet diagnostics interface
Gateway + Safety Monitor in one housing:
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1891
• Enhanced funcional range
of Bihl+Wiedemann Safety Monitor BWU2044
• Compatible with the wide range of Bihl+Wiedemann power supplies
1 AS-i 3.0 Master PROFIBUS Slave
BWU2206
PROFIBUS interface
according to DIN 19 245, part 3
Baud rates
9,6 KBaud up to 12 000 KBaud, automatic recogition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Diagnostics interface
Ethernet
AS-i cycle time
150 ms * (number of slaves + 2)
Safety Monitor
Release circuits
16
Start delay
< 10 s
Respond delay
< 40 ms
Inputs
2 x EDM/ inputs of external device monitoring circuits 1 and 2
2 x Start / start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs
4 x 4 x output switching elements (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Display
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
Buttons
4
Electrical data
Operating current
master power supply, approx 300 mA out of the AS-i network
Operating voltage
AS-i voltage 30 V DC
Voltage of insulation
≥ 500 V
Other Fieldbuses/
Master Simulators
Article no.
US
AS-i Safety
C
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Chip card for storage of configuration data
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2206 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 231
Price Lists
UL-specifications (UL508)
Article no.
BWU2206
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN 954-1, category 4
EN ISO 13 849-1:2008, performance level e
Housing
master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts and
vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections: Gateway + Safety Monitor
1.13
1.14
1.23
1.24
2.13
2.14
2.23
2.24
Freigabe
(Release)
Freigabe
(Release)
EDM inputs
Start inputs
output switching elements
Freigabe
(Release)
EDM inputs
Start inputs
output switching elements
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
Eingänge
(Inputs)
1.Y1 (EDM 1)
2.Y1 (EDM 2)
1.Y2 (Start 1)
2.Y2 (Start 2)
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools (art. no. BW2501)
• Serial PROFIBUS-Master (art. no. BW1258, see also page 197)
• PROFIBUS-DP-Master simulator (art. no. BW1257, see also page 196)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS Gateway
with integrated Safety Monitor
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 232
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, PROFINET-Slave
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Full functional range
of Bihl+Wiedemann PROFINET Gateway BWU2239!
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
Monitor configuration can be „arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article no.
BWU2330
PROFINET interface
RJ-45
Conformance class
B
Baud rates
US
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 µs * (number of slaves + 2)
Safety monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave adresses and error messages
LED power
power on
LED PROFINET
PROFINET master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 233
Other Fieldbuses/
Master Simulators
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
AS-i Safety
Safe AS-i outputs are supported on both AS-i networks
Price Lists
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article no.
BWU2330
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2330 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Other Fieldbuses/
Master Simulators
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety Monitor block diagram:
Connections:
Gateway + Safety Monitor
24 V
3.14
0V
4.14
1.13
1.14
2.13
2.14
Freigabe
(Release)
AS-i Safety
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
output switching elements
EDM/START inputs
Freigabe
(Release)
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
EDM/START inputs
output switching elements
Price Lists
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
Accessories:
• Software ASIMON 3 G2 and AS-i Control-Tools with serial cable for AS-i Master/monitors in stainless steel
(art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 234
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, PROFINET Slave
• Version “1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks“
• Full functional range of
Bihl+Wiedemann PROFINET Gateways BWU2238!
• Enhanced functional range
of Bihl+Wiedemann Sicherheitsmonitors BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
• 4 CAT4, SIL 3 safe output circuits on the Monitor
Two sets of safe relays
Two sets of fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor programm size not restricted
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
BWU2237
PROFINET interface
RJ-45
Conformance class
B
Baud rates
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety Monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max.contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Other Fieldbuses/
Master Simulators
Article number
US
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFINET
PROFINET master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 235
AS-i Safety
chip card for storage of configuration data
Price Lists
Card slot
Displays
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2237
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply, approx 300 mA out of AS-i network
Operating voltages
30 V, 9 W
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2237 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
IEC 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety Monitor block diagram:
Connections:
24 V
1.13 0 V 24 V 2.13
2.Y2 + 4 2.Y1 + 3
output switching elements
EDM/START inputs
3.14
0V
4.14
1.13
1.14
2.14
2.13
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
PROFINET
Other Fieldbuses/
Master Simulators
Gateway + Safety Monitor
+
AS-i Safety
Sicherheitsmonitor
(Safety Monitor)
-
+
-
+ASI 1–
+ASI 1–
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
ouptu switching elements
+ ASI 2 –
+
AS-i +PWR- (max. 8A)
Accessories:
Price Lists
• Software ASIMON 3 G2 and AS-i Contro Tools with serial cable for AS-i Master/monitors in stainless steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 236
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
1 AS-i 3.0 Single Master, PROFINET Slave
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Full functional range
of Bihl+Wiedemann PROFINET Gateway BWU1912!
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single monitor configuration!
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
Monitor configuration can be „arbitrarily large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article number
BWU2307
PROFIBUS interface
RJ-45
Conformance class
B
Baud rates
US
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Output:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFINET
PROFINET master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 237
Other Fieldbuses/
Master Simulators
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
AS-i Safety
Safe AS-i outputs are supported on both AS-i networks
Price Lists
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
AS-i 3.0 PROFINET Gateway
with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2307
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
AS-i voltage 30 VDC
Voltage of insulation
≥ 500 V
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2307 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Other Fieldbuses/
Master Simulators
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety Monitor block diagram:
Connections:
24 V
3.14
0V
4.14
1.13
1.14
2.13
2.14
Freigabe
(Release)
AS-i Safety
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
output switching elements
EDM/START inputs
Freigabe
(Release)
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
EDM/START inputs
output switching elements
Price Lists
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/monitors in stainless steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 238
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 EtherNet/IP+Modbus TCP
Gateway with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, EtherNet/IP+Modbus TCP Slave
• Modbus TCP from ident. no. 13076 (see lateral label)
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Full functional range
of Bihl+Wiedemann EtherNet/IP Gateway BWU1829!
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
• integrated switch
• Operation using a single Monitor configuration!
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
16 release circuits
• 4 CAT4, SIL 3 safe output circuits on the Monitor
Two sets of safe relays
Two sets of fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor configuration can be “arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
RJ-45: 10/100 MBaud Ethernet + Modbus TCP acc. to IEEE 802.3, integrated
switch
Baud rates
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Output:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave addresses and error messages
LED power
power on
LED net
Ethernet network active
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 239
Other Fieldbuses/
Master Simulators
BWU2317
AS-i Safety
Ethernet/IP interface
Price Lists
Article number
US
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
AS-i 3.0 EtherNet/IP+Modbus TCP
Gateway with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2317
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
AS-i voltage 30 V DC
Voltage of insulation
≥ 500 V
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2317 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts and
vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections: Gateway + Safety Monitor
24 V
3.14
0V
1.13
2.Y2
4.14
1.13
1.14
24 V 2.13
2.Y1
+3
2.14
2.13
Freigabe
(Release)
AS-i Safety
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
+
-
+
+ASI 1–
ASI 1 +PWR- (max. 8A)
Eingänge
(Inputs)
Price Lists
0V
+4
output switching elements
EDM/START inputs
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
-
+
-
+
-
+1
1.14
1.Y1
3.14
+2
4.14
1.Y2
2.14
EDM/START inputs
output switching elements
+ ASI 2 –
ASI
+ 2 +PWR- (max. 8A)
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 240
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 EtherNet/IP+Modbus TCP
Gateway with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, EtherNet/IP+Modbus TCP Slave
• Modbus TCP from ident. no. 13077 (see lateral label)
• Version “1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks“
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
• switch integrated
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration!
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
• 4 CAT4, SIL 3 safe output circuits on the Monitor
Two sets of safe relays
Two sets of fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor configuration can be “arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
BWU2267
Interfaces
Ethernet interface
RJ-45: 10/100 MBaud Ethernet + Modbus TCP acc. to IEEE 802.3, switch integrated
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Output:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Other Fieldbuses/
Master Simulators
Article number
US
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
indication of slave addresses and error messages
LED power
power on
LED net
Ethernet network active
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 241
Price Lists
LCD
AS-i Safety
Displays
AS-i 3.0 EtherNet/IP+Modbus TCP
Gateway with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2267
Interfaces
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply, approx. 300 mA out of AS-i network
Operating voltage
AS-i voltage 30 V DC
Voltage of insulation
≥ 500 V
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2267 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
Other Fieldbuses/
Master Simulators
0°C … +55°C
Storage temperature
800 g
Safety Monitor block diagram:
Connections: Gateway + Safety Monitor
24 V
3.14
0V
1.13
2.Y2
4.14
1.13
1.14
2.13
2.14
Freigabe
(Release)
AS-i Safety
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
24 V 2.13
+3
2.Y1
output switching elements
EDM/START inputs
Freigabe
(Release)
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
+
-
+
-
+ASI 1–
+ASI 1–
Eingänge
(Inputs)
0V
+4
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
output switching elements
+ ASI 2 –
+
AS-i +PWR- (max. 8A)
Price Lists
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 242
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 EtherNet/IP+Modbus TCP
Gateway with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
1 AS-i 3.0 Single Master, EtherNet/IP+Modbus TCP-Slave
• Modbus TCP from ident. no. 13078 (see lateral label)
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
• integrated switch
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration!
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
• 4 CAT4, SIL3 safe output circuits on the monitor
two sets of safe relays
two sets of fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor configuration can be „arbitrarily large“
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Ethernet interface/IP interface
Baud rates
BWU2273
RJ-45: 10/100 MBaud Ethernet + Modbus TCP acc. to IEEE 802.3, integrated switch
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety monitor
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Output:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Other Fieldbuses/
Master Simulators
Article no.
US
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
chip card for storage of configuration data
LCD
indication of slave addresses and error messages
LED power
power on
LED net
Ethernet network active
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 243
Price Lists
Card slot
Displays
AS-i Safety
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
AS-i 3.0 EtherNet/IP+Modbus TCP
Gateway with integrated Safety Monitor
AS-i Master/Gateways/
Links/Scanner
Article no.
BWU2273
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
AS-i voltage 30 VDC
Voltage of insulation
≥ 500 V
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2273 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts and
vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections: Gateway + Safety Monitor
24 V
3.14
0V
1.13
2.Y2
4.14
1.13
0V
+4
24 V 2.13
2.Y1
+3
output switching elements
EDM/START inputs
1.14
2.14
2.13
Freigabe
(Release)
AS-i Safety
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Ethernet/IP
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
Sicherheitsmonitor
(Safety Monitor)
+
-
+
-
+ASI 1–
+ASI 1–
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
output switching elements
ASI 1 +PWR– (max. 8A)
+
+ASI 2- / 24V 0V
Price Lists
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 244
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 EtherCAT Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
2 AS-i 3.0 Master, EtherCAT/IP Slave
• Version “1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks“
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration!
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
16 release circuits
• 4 CAT4, SIL 3 safe output circuits on the Monitor
Two sets of safe relays
Two sets of fast electronic safe outputs
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor configuration can be “arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article number
EtherCAT/IP interface
Baud rates
US
BWU2281
RJ-45
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Safe AS-i outputs are supported on both AS-i networks
Release circuits
4
Start delay
< 10 s
Respond delay
< 40 ms
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Output:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Other Fieldbuses/
Master Simulators
Safety monitor
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
indication of slave addresses and error messages
LED power
power on
LED EtherCAT
EtherCAT/IP master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 245
Price Lists
LCD
AS-i Safety
Displays
AS-i 3.0 EtherCAT Gateway
with integrated Safety Monitor
BWU2281
Operating current
master power supply, approx. 300 mA out of AS-i network
Operating voltage
AS-i voltage 30 V DC
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2281 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
IEC 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety Monitor block diagram:
Connections: Gateway + Safety Monitor
24 V
3.14
0V
4.14
1.13
1.14
2.13
2.14
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
1.13
2.Y2
+
-
+
-
+ASI 1–
+3
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
output switching elements
+ ASI 2 –
+
AS-i +PWR- (max. 8A)
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
Price Lists
AS-i Safety
+ASI 1–
Eingänge
(Inputs)
24 V 2.13
2.Y1
output switching elements
EDM/START inputs
Sicherheitsmonitor
(Safety Monitor)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
0V
+4
ETHERCAT
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article number
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 246
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 EtherCAT Gateway
with integrated Safety Monitor
AS-i-Master/Gateways/
Links/Scanner
1 AS-i 3.0 Single Master, EtherCAT-Slave
• redundant power supply out of AS-i
all fundamental functions of the device remain available even in case of power
failure in one of the two AS-i networks
• Version “1 gateway + 1 power supply + 1 Safety Monitor for 2 AS-i networks“
• Enhanced functional range
of Bihl+Wiedemann Safety Monitor BWU2000!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
Monitor configuration can be „arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article number
BWU2338
EtherCAT interface
Baud rates
Serial interface
AS-i cycle time
RJ-45
10/100 MBaud
RS 232
150 μs * (number of slaves + 2)
Safety Monitor
Release circuits
Start delay
Respond delay
Inputs:
4 x EDM/Start
Outputs:
4 x output switching elements
Card slot
Display
LCD
LED power
LED EtherCAT
LED config error
LED U AS-i
LED AS-i active
LED prg enable
LED prj mode
LED AUX
4 x LED EDM/Start
4 x LED output circuit
US
4
< 10 s
< 40 ms
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
Max. contact load: 0,5 A DC-13 at 30 V
chip card for storage of configuration data
indication of slave addresses and error messages
power on
EtherCAT/IP master recognized
configuration error
AS-i voltage OK
AS-i normal operation active
automatic address programming enabled
configuration mode active
auxiliary power
state of inputs:
LED off:
open
LED on:
closed
state of output circuits:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 247
Other Fieldbuses/
Master Simulators
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
AS-i Safety
Safe AS-i outputs are supported on both AS-i networks
Price Lists
• 4 CAT4, SIL 3 safe output circuits on the Monitor
two sets of safe relays
two sets of fast electronic safe outputs
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
16 release circuits
AS-i 3.0 EtherCAT Gateway
with integrated Safety Monitor
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2338
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA)
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
AS-i voltage 30 V DC
≥ 500 V
Operating voltage
Voltage of insulation
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2338 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category (IEC 60 529) IP20
Tolerable loading referring to
according to EN 61 131-2
impacts and vibrations
Weight
800 g
Safety Monitor block diagram:
Connections:
Gateway + Safety Monitor
1.13
2.Y2
3.14
0V
24 V 2.13
+4
2.Y1
+3
output switching elements
EDM/Start inputs
4.14
1.13
0V
1.14
2.14
2.13
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
EtherCAT
Other Fieldbuses/
Master Simulators
24 V
Freigabe
(Release)
+
-
+
-
Sicherheitsmonitor
(Safety Monitor)
AS-i Safety
+ASI 1–
+ASI 1–
+ ASI 2 –
Eingänge
(Inputs)
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/Start inputs
output switching elements
+
ASI
1 +PWR- (max. 4A)
Accessories:
Price Lists
• Software ASIMON 3 G2 and AS-i Control Tools" with serial cable for AS-i Master/Monitor in Stainless Steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 248
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 1 AS-i network
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• AS-i-Safety input slaves report via PROFIsafe
• AS-i-Safety output slaves switch via PROFIsafe
1 AS-i 3.0 Single Master, PROFIBUS Slave
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1567!
AS-i-Master/Gateways/
Links/Scanner
PROFIsafe for 1 AS-i network
• Compatible with the wide range of
Bihl+Wiedemann power supplies
Safe AS-i outputs are supported
• Multiple safe AS-i outputs possible via a single AS-i address
BWU2479
PROFIBUS interface
according to DIN 19 245, part 3
Baud rates
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
Projektierungsmodus aktiv
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
Other Fieldbuses/
Master Simulators
Article no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Chip card for storage of configuration data
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2479 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
EN 954-1:1996, category 4
EN 62 061:2005, SIL 3
EN 61 508:2006, SIL 3
EN ISO 13 849-1:2008, performance level e
EN ISO 13 849-2:2008
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 249
Price Lists
External Protection
AS-i Safety
UL-specifications (UL508)
AS-i Master/Gateways/
Links/Scanner
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 1 AS-i network
Article no.
BWU2479
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to
impacts and vibrations
according to EN 61 131-2
Weight
800 g
PROFIBUS
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Connections:
Other Fieldbuses/
Master Simulators
+
-
+
-
+
-
+ASI 1–
+ASI 1–
24V ext.
+
ASI 1 +PWR– (max. 4A)
• ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
• Serial PROFIBUS Master (art. no. BW1258, see also Seite 197)
• PROFIBUS-DP Master simulator (art. no. BW1257, see also Seite 196)
Price Lists
AS-i Safety
Accessories:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 250
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 1 AS-i network
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Version "1 gateway + 1 power supply + 1 Safety Monitor for 1 AS-i network"
• AS-i-Safety input slaves report via PROFIsafe
• AS-i-Safety output slaves switch via PROFIsafe
1 AS-i 3.0 Single Master, PROFIBUS-Slave
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1891!
AS-i-Master/Gateways/
Links/Scanner
PROFIsafe for 1 AS-i network
• Compatible with the wide range of
Bihl+Wiedemann power supplies
4 release circuits SIL 3, CAT. 4 on the monitor switch via PROFIsafe
Safe AS-i outputs are supported on both AS-i networks
• Multiple safe AS-i outputs possible via a single AS-i address
Chip card for storage of configuration data
Article number
PROFIBUS interface
BWU2434
according to DIN 19 245, part 3
Baud rates
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
• 2 x relays + 2 x fast electronic safe outputs
Release circuits
4
Start delay
< 10 s
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Other Fieldbuses/
Master Simulators
Safety unit
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 251
Price Lists
LCD
AS-i Safety
Displays
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 1 AS-i network
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2434
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2434 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
EN 954-1:1996, category 4
EN 62 061:2005, SIL 3
EN 61 508:2006, SIL 3
EN ISO 13 849-1:2008, performance level e
EN ISO 13 849-2:2008
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
• ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
• Serial PROFIBUS Master (art. no. BW1258, see also page 197)
• PROFIBUS-DP Master simulator (art. no. BW1257, see also page 196)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Accessories:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 252
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 2 AS-i networks
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• AS-i Safety input slaves report via PROFIsafe
• AS-i-Safety output slaves switch via PROFIsafe
2 AS-i 3.0 Master, PROFIBUS Slave
• Full functional range
of Bihl+Wiedemann PROFIBUS Gateway BWU1568!
AS-i-Master/Gateways/
Links/Scanner
PROFIsafe for 2 AS-i networks
• Compatible with the wide range of
Bihl+Wiedemann power supplies
4 release circuits SIL 3, Cat. 4 on the monitor switch via PROFIsafe
• 2 sets of safe relays + 2 sets of fast electronic safe outputs
PROFIBUS interface
BWU2214
according to DIN 19 245, part 3
Baud rates
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety unit
Release circuits
4
Start delay
< 10 s
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave adresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED aus:
open
LED an:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 253
Other Fieldbuses/
Master Simulators
Article no.
AS-i Safety
Chip card for storage of configuration data
Price Lists
• Multiple safe AS-i outputs possible via a single AS-i address
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Safe AS-i outputs are supported on both AS-i networks
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 2 AS-i networks
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article no.
BWU2214
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2214 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
EN 954-1:1996
EN 62 061:2005, SIL 3
EN 61 508:2006, SIL 3
EN ISO 13 849-1:2008, performance level e
EN ISO 13 849-2:2008
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety unit block diagram:
Connections:
Gateway + Safety unit
1.13
2.Y2
0V
24 V 2.13
+4
2.Y1
+3
PROFIBUS
Other Fieldbuses/
Master Simulators
output switching elements
EDM/START inputs
Sicherheitseinheit
(Safety Unit)
+
-
+
AS-i Safety
+ASI 1–
ASI 1 +PWR- (max. 8A)
-
+
-
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
output switching elements
+ ASI 2 –
ASI
+ 2 +PWR- (max. 8A)
Accessories:
Price Lists
• Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
• Serial PROFIBUS Master (art. no. BW1258, see also page 197)
• PROFIBUS-DP Master simulator (art. no. BW1257, see also page 196)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 254
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 2 AS-i networks
• AS-i Safety input slaves report via PROFIsafe
• AS-i-Safety output slaves switch via PROFIsafe
2 AS-i 3.0 Master, PROFIBUS-Slave
• Version „1 gateway + 1 power supply for 2 AS-i networks“
• Full functional range of
Bihl+Wiedemann PROFIBUS-Gateways BWU1569!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
AS-i-Master/Gateways/
Links/Scanner
PROFIsafe for 2 AS-i networks
4 release circuits SIL 3, CAT. 4 on the monitor switch via PROFIsafe
• 2 x relays + 2 x fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• Multiple safe AS-i outputs possible via a single AS-i address
9,6 kBaud up to 12 000 kBaud, automatic recognition
DP functions
imaging of the AS-i-Slaves as I/O data of the PROFIBUS
complete diagnosis and configuration via the PROFIBUS DP
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety unit
Release circuits
4
Start delay
< 10 s
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max.contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFIBUS
PROFIBUS master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Operating current
master power supply, approx 300 mA out of AS-i network
Operating voltages
30 V, 9 W
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 255
Other Fieldbuses/
Master Simulators
according to DIN 19 245, part 3
Baud rates
AS-i Safety
PROFIBUS interface
BWU2215
Price Lists
Article number
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Chip card for storage of configuration data
AS-i 3.0 PROFIBUS Gateway,
PROFIsafe for 2 AS-i networks
BWU2215
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2215 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
EN 954-1:1996
EN 62 061:2005, SIL 3
EN 61 508:2006, SIL 3
EN ISO 13 849-1:2008, performance level e
EN ISO 13 849-2:2008
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety unit block diagram:
Connections:
Gateway + Safety unit
1.13
2.Y2
0V
24 V 2.13
+4
2.Y1
+3
PROFIBUS
output switching elements
EDM/START inputs
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article number
Sicherheitseinheit
(Safety Unit)
+
-
+
-
+ASI 1–
+ASI 1–
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/START inputs
ouptut switching elements
+ ASI 2 –
Accessories:
• ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
• Serial PROFIBUS-Master (art. no. BW1258, see also page 197)
• PROFIBUS-DP Master simulator (art. no. BW1257, see also page 196)
Price Lists
AS-i Safety
+
AS-i +PWR- (max. 8A)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 256
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFINET Gateway,
PROFIsafe for 2 AS-i networks
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• AS-i Safety input slaves report via PROFIsafe
• AS-i-Safety output slaves switch via PROFIsafe
2 AS-i 3.0 Master, PROFINET Slave
• Full functional range
of Bihl+Wiedemann PROFINET Gateway BWU2239!
AS-i-Master/Gateways/
Links/Scanner
PROFINET/PROFIsafe for 2 AS-i networks
• Compatible with the wide range of
Bihl+Wiedemann power supplies
4 release circuits SIL 3, Cat. 4 on the monitor switch via PROFIsafe
• 2 sets of safe relays + 2 sets of fast electronic safe outputs
Article no.
BWU2421
PROFIBUS interface
RJ-45
Conformance class
B
Baud rates
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety unit
Release circuits
4
Start delay
< 10 s
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: Start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave adresses and error messages
LED power
power on
LED PROFINET
PROFINET master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic addresses programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Other Fieldbuses/
Master Simulators
Chip card for storage of configuration data
AS-i Safety
• Multiple safe AS-i outputs possible via a single AS-i address
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Safe AS-i outputs are supported on both AS-i networks
Operating current
master power supply,
max. 300 mA out of AS-i circuit 1 (approx. 70 mA ... 300 mA),
max. 300 mA out of AS-i circuit 2 (approx. 70 mA ... 300 mA);
in sum max. 370 mA
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 257
Price Lists
Electrical data
AS-i 3.0 PROFINET Gateway,
PROFIsafe for 2 AS-i networks
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Article no.
BWU2421
Operating voltage
30 V, 9 W
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2421 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
EN 954-1:1996
EN 62 061:2005, SIL 3
EN 61 508:2006, SIL 3
EN ISO 13 849-1:2008, performance level e
EN ISO 13 849-2:2008
Housing
AS-i master housing in stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety unit block diagram:
Connections:
Gateway + Safety unit
Other Fieldbuses/
Master Simulators
output switching elements
EDM/START inputs
AS-i Safety
Sicherheitseinheit
(Safety Unit)
EDM/START inputs
output switching elements
Accessories:
Price Lists
Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 258
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i 3.0 PROFINET Gateway,
PROFIsafe for 2 AS-i networks
• AS-i Safety input slaves report via PROFIsafe
• AS-i Safety output slaves switch via PROFIsafe
2 AS-i 3.0 Master, PROFINET Slave
• Version “1 gateway + 1 power supply for 2 AS-i networks“
• Full functional range of
Bihl+Wiedemann PROFINET Gateways BWU2238!
• Compatible with the wide range of
Bihl+Wiedemann power supplies
AS-i-Master/Gateways/
Links/Scanner
PROFIsafe for 2 AS-i networks
4 release circuits SIL 3, CAT. 4 on the monitor switch via PROFIsafe
• 2 x relays + 2 x fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• multiple safe AS-i outputs possible via a single AS-i address
RJ-45
Conformance class
B
Baud rates
10/100 MBaud
Serial interface
RS 232
AS-i cycle time
150 μs * (number of slaves + 2)
Safety unit
Release circuits
4
Start delay
< 10 s
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max.contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Card slot
chip card for storage of configuration data
Displays
LCD
indication of slave addresses and error messages
LED power
power on
LED PROFINET
PROFINET master recognized
LED config error
configuration error
LED U AS-i
AS-i voltage OK
LED AS-i active
AS-i normal operation active
LED prg enable
automatic address programming enabled
LED prj mode
configuration mode active
LED AUX
auxiliary power
4 x LED EDM/Start
state of inputs:
LED off:
open
LED on:
closed
4 x LED output circuit
state of output circuits:
LED off:
open
LED on:
closed
Operating current
master power supply, approx 300 mA out of AS-i network
Operating voltages
30 V, 9 W
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 259
Other Fieldbuses/
Master Simulators
PROFINET interface
AS-i Safety
BWU2383
Price Lists
Article number
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Chip card for storage of configuration data
AS-i 3.0 PROFINET Gateway,
PROFIsafe for 2 AS-i networks
AS-i Master/Gateways/
Links/Scanner
Article number
BWU2383
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2383 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 50 295
EN 61 000-6-2
EN 61 000-6-4
EN954-1:1996
EN 62 061:2005, SIL 3
EN 61 508:2006, SIL 3
EN ISO 13 849-1:2008, performance level e
EN ISO 13 849-2:2008
Housing
AS-i master housing in stainless steel
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 100 / 96
Protection category IEC 60 529
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
Weight
800 g
Safety unit block diagram:
Connections:
Gateway + Safety unit
1.13
2.Y2
0V
24 V 2.13
+4
2.Y1
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
+3
output switching elements
EDM/START inputs
Other Fieldbuses/
Master Simulators
PROFINET
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Ambient operating temperature
Sicherheitseinheit
Safety Unit
+
-
+
-
+ASI 1–
+ASI 1–
+ ASI 2 –
+
-
EDM/START inputs
ouptut switching elements
+
AS-i +PWR- (max. 8A)
• ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/Monitors in stainless steel (art. no. BW2071)
Price Lists
AS-i Safety
Accessories:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 260
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Monitor
Art. No.
Characteristics
AS-i Safety Monitor in stainless steel,
generation II
BWU2205
16 release circuits,
2 indepentent output switching elements,
Ethernet diagnostics interface
262
AS-i Safety Monitor in stainless steel,
generation II
BWU2000
16 release circuits,
4 indepentent output switching elements,
RS 232 diagnostics interface
264
BWU2186
16 release circuits,
2 indepentent output switching elements,
RS 232 diagnostics interface
266
BW2441
AS-i Master disengageable, 8 release circuits,
8 / 4 safe inputs and 2 (4) electronical safe outputs,
USB interface
268
BW2557
8 release circuits, 8 / 4 safe inputs and
2 (4) electronical safe outputs, USB interface
Safety Basic Monitor
Safety Basic Monitor Starter Kit
270
BW1764
advanced monitor, 1 release circuit, 40 ms
BW1765
advanced monitor, 2 release circuits, 40 ms
271
Price Lists
AS-i Safety
AS-i Safety Monitor
BW2512
P.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Module
Other Fieldbuses/
Master Simulators
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Safety Monitor
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 261
AS-i Master/Gateways/
Links/Scanner
AS-i Safety Monitor in Stainless Steel
AS-i Safety Monitor Generation II
with Ethernet diagnostics interface
Redundant Power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
Emergency stop control device in Stainless Steel housing
16 release circuits
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Meets safety-relevant standards
up to category 4/SIL 3
LCD display
Chip card for storage of configuration data
C
US
Article no. BWU2205: AS-i Safety Monitor Generation II, safe AS-i outputs are supported
The AS-i Safety Monitor in Stainless Steel is an emergency stop
control device. It monitors the assigned safety-related AS-i sensors by the configuration software ASIMON 3 G2. In case an
emergency stop should be required or if a fault occurs, the AS-i
safety monitor in its protective mode can switch off the system
within a response time of 40 ms at most.
The safety monitor in the second generation offers a stainless
steel housing with a LCD display for indication of slave addresses
Article no.
BW2205
Diagnostics interface
Ethernet
Safety monitor
advanced monitor, generation II
Release circuits
16
Start delay
< 10 s
and error messages. The configuration data are stored in the
integral EEPROM and they can be overwritten by data stored on
the chip card and vice versa.
The AS-i Safety Monitor enables the use of sensor-controlled
safety components according to EN 954-1 up to category 4/SIL 3.
Usage of extensive logic components and formation of AS-i
groups is possible, too.
Respond delay
< 40 ms
Inputs
2 x EDM / inputs of external device monitoring circuits 1 and 2
2 x Start / start inputs, output circuits 1 and 2
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs
4 x output switching elements, output circuits 1 and 2
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Interface
Ethernet diagnostic interface, chip card slot
AS-i Safety
Displays/buttons
LCD
indication of slave addresses and error messages
LED power
AS-i voltage OK
LED U AS-i / fault
communication error on AS-i line / error lock, release circuit active
LED ready
LED on: start-up/restart-disable active
LED flashing: external test necessary
2 x LEDs channel 1, channel 2
contacts of the safety outputs (OSSD) are:
LED off: open
LED on: closed
LED flashing: delay time is running at stop category 1
Buttons
4
Price Lists
Electrical data
Operating voltage
24 V DC (26,5 … 31,6 V out of AS-i)
Operating current
max. 200 mA out of AS-i circuit 1 (approx. 45 mA ... 200 mA),
max. 200 mA out of AS-i circuit 2 (approx. 45 mA ... 200 mA);
in sum max. 245 mA
Voltage of insulation
≥ 500 V
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 262
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Monitor in Stainless Steel
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2205 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN 954-1, category 4
EN ISO 13 849-1:2008, performance level e
Housing
stainless steel
Ambient operating temperature
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 85 / 96
Protection category (IEC 60 529)
IP20
Tolerable loading referring to
impacts and vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections:
1.13
1.14
1.23
1.24
Start inputs
EDM inputs
Output switching elements
AS-i-Master/Gateways/
Links/Scanner
BW2205
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no.
UL-specifications (UL508)
2.24
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Start inputs
EDM inputs
Output switching elements
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
Eingänge
(Inputs)
1.Y1 (EDM 1)
2.Y1 (EDM 2)
1.Y2 (Start 1)
2.Y2 (Start 2)
Price Lists
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools (article no. BW2501)
AS-i Safety
2.23
Other Fieldbuses/
Master Simulators
2.14
2.13
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 263
AS-i Safety Monitor in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
• Redundant power supply out of AS-i:
all fundamental functions of the device remain available even in case of
power failure in one of the two AS-i networks
• Operation using a single Monitor configuration
Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
16 release circuits
• 4 CAT4, SIL 3 release circuits on the Monitor
Two sets of safe relays
Two sets of fast electronic safe outputs
Safe AS-i outputs are supported on both AS-i networks
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Monitor configuration can be „arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article no. BWU2000: AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
The AS-i Safety Monitor in stainless steel is an emergency stop
control device. It monitors the assigned safety-related AS-i
sensors by the configuration software ASIMON 3 G2. In case an
emergency stop should be required or if a fault occurs, the AS-i
safety monitor in its protective mode can switch off the system
within a response time of 40 ms at most.
The safety monitor in the second generation offers a stainless
steel housing with a LCD display for indication of slave addresses
Article no.
Other Fieldbuses/
Master Simulators
US
Safety monitor
Release circuits
and error messages. The configuration data are stored in the
integral EEPROM and they can be overwritten by data stored on
the chip card and vice versa.
The AS-i Safety Monitor enables the use of sensor-controlled
safety components according to EN 954-1 up to category 4/SIL 3.
Usage of extensive logic components and formation of AS-i
groups is possible, too.
BWU2000
advanced monitor
4
Start delay
< 10 s
Respond delay
< 40 ms
Baud rate
19,2 kBaud, no parity, 1 start bit, 1 stop bit, 8 data bits
Inputs:
4 x EDM/Start
EDM: inputs to monitor external devices
Start: start inputs
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs:
4 x output switching elements
relay outputs (output circuits 1 and 2)
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
semiconductor outputs (output circuits 3 and 4)
max. contact load: 0,5 A DC-13 at 30 V
Price Lists
AS-i Safety
Interface
RS 232, chip card slot
Displays
LCD
indication of slave addresses and error messages
LED power
AS-i voltage OK
LED fault
LED on: communication error on AS-i network
LED flashing: at least 1 OSSD in state „red flashing“
LED ready
LED on: start-up/restart-disable active
LED flashing: external test necessary
LEDs U AS-i 1 / U AS-i 2
AS-i 1/AS-i 2 sufficiently voltage supplied
LED AUX
auxiliary power
4 x LEDs EDM/Start
state of inputs:
LED off:
open
LED on:
closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 264
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Monitor in Stainless Steel
BWU2000
4 x LEDs output circuits
AS-i-Master/Gateways/
Links/Scanner
Article no.
state of output circuits:
LED off:
open
LED on:
closed
Electrical data
Operating voltage
24 V DC (26,5 … 31,6 V out of AS-i)
Operating current
max. 200 mA out of AS-i circuit 1 (approx. 45 mA ... 200 mA),
max. 200 mA out of AS-i circuit 2 (approx. 45 mA ... 200 mA);
in sum max. 245 mA
≥ 500 V
Voltage of insulation
External Protection
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The devices BWU2000 from Bihl + Wiedemann GmbH were safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN ISO 13 849-1:2008, performance level e
Housing
stainless steel
Ambient operating temperature
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
UL-specifications (UL508)
0°C … +55°C
Storage temperature
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 85 / 96
Protection category (IEC 60 529)
IP20
Tolerable loading referring to impacts according to EN 61 131-2
and vibrations
800 g
Connections:
24 V
3.14
0V
4.14
1.13
1.14
2.13
2.14
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
Freigabe
(Release)
1.13
2.Y2
24 V 2.13
+3
2.Y1
output switching elements
EDM/Start inputs
Freigabe
(Release)
Freigabe
(Release)
Sicherheitsmonitor
(Safety Monitor)
+
-
+
-
+AS I 1–
AS I 1 +PWR– (max. 4A)
Eingänge
(Inputs)
0V
+4
Other Fieldbuses/
Master Simulators
Safety Monitor block diagram:
1.Y1 (EDM 1 / Start 1)
2.Y1 (EDM 2 / Start 2)
1.Y2 (EDM 3 / Start 3)
2.Y2 (EDM 4 / Start 4)
+
-
+1
1.14
1.Y1
3.14
+ 2 1.Y2
4.14 2.14
EDM/Start inputs
output switching elements
+AS I 2–
AS-i Safety
Weight
AS I 2 +PWR– (max. 4A)
Price Lists
Accessories:
• Programming software ASIMON 3 G2 and AS-i Control Tools with cable (article no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 265
AS-i Safety Monitor in Stainless Steel
AS-i Master/Gateways/
Links/Scanner
1 AS-i Safety Monitor in Stainless Steel for 2 AS-i networks
Redundant power supply out of AS-i:
all fundamental functions of the device remain available even
in case of power failure in one of the two AS-i networks
Operation using a single Monitor configuration
• Monitor processes safety slaves on two AS-i networks
Coupling between the two networks superfluous
16 release circuits
• 2 CAT4, SIL 3 release circuits on the Monitor
Two sets of safe relays
Safe AS-i outputs are supported on both AS-i networks
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
• 16 independent AS-i outputs
Multiple safe AS-i outputs possible via a single AS-i address
Monitor configuration can be „arbitrarily“ large
• 256 configuration blocks (previously 48)
Identical reaction time due to artificial limitation to 256 configuration blocks
Chip card for storage of configuration data
C
Article no. BWU2186: AS-i Safety Monitor Generation II
The AS-i Safety Monitor in Stainless Steel is an emergency stop
control device. It monitors the assigned safety-related AS-i sensors by the configuration software ASIMON 3 G2. In case an
emergency stop should be required or if a fault occurs, the AS-i
safety monitor in its protective mode can switch off the system
within a response time of 40 ms at most.
The safety monitor in the second generation offers a stainless
steel housing with a LCD display for indication of slave addresses
Other Fieldbuses/
Master Simulators
US
Article no.
BWU2186
Safety monitor
advanced monitor, generation II
Release circuit
2-channel
Start delay
< 10 s
and error messages. The configuration data are stored in the
integral EEPROM and they can be overwritten by data stored on
the chip card and vice versa.
The AS-i Safety Monitor enables the use of sensor-controlled
safety components according to EN 954-1 up to category 4/SIL 3.
Usage of extensive logic components and formation of AS-i
groups is possible, too.
Respond delay
< 40 ms
Baud rate
19,2 Kbaud, no parity, 1 start bit, 1 stop bit, 8 data bits
Inputs
2 x EDM / inputs of external device monitoring circuits 1 and 2
2 x Start / start inputs, output circuits 1 and 2
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Outputs
4 x output switching elements, output circuits 1 and 2
max. contact load: 3 A AC-15 at 30 V, 3 A DC-13 at 30 V
Interface
RS 232, chip card slot
AS-i Safety
Displays/buttons
LCD
indication of slave addresses and error messages
LED power
AS-i voltage OK
LED U AS-i / fault
communication error on AS-i line / error lock, release circuit active
LED ready
LED on: start-up/restart-disable active
LED flashing: external test necessary
2 x LEDs channel 1, channel 2
contacts of the safety outputs (OSSD) are:
LED off: open / LED on: closed / LED flashing: delay time is running at stop category 1
Buttons
4
Price Lists
Electrical data
Operating voltage
24 V DC (26,5 … 31,6 V out of AS-i)
Operating current
max. 200 mA out of AS-i circuit 1 (approx. 45 mA ... 200 A),
max. 200 mA out of AS-i circuit 2 (approx. 45 mA ... 200 mA);
in sum max. 245 mA
Voltage of insulation
≥ 500 V
UL-specifications (UL508)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 266
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
BWU2186
An isolated source with a secondary open circuit voltage of ≤ 30 VDC
with a 3 A maximum over current protection.
Over current protection is not required when a Class 2 source is employed.
in general
UL mark does not provide UL certification for any functional safety rating
or aspects of the above devices.
cTÜVus
The device BWU2186 from Bihl+Wiedemann GmbH was safety certified
by TÜV Rheinland of North America, Inc. according to UL-standards
and meet the safety requierements for the North American market.
Standards
EN 61 000-6-2
EN 61 000-6-4
EN 62 061:2005, SILCL 3
EN 61 508:2001, SIL 3
EN 954-1, category 4
EN ISO 13 849-1:2008, performance level e
Housing
stainless steel
Ambient operating temperature
Storage temperature
0°C … +55°C
-25°C … +85°C
Dimensions (L / W / H in mm)
120 / 85 / 96
Protection category (IEC 60 529)
IP20
Tolerable loading referring to
impacts and vibrations
according to EN 61 131-2
Weight
800 g
Safety Monitor block diagram:
Connections:
1.13
2.Y2
1.13
1.14
1.23
1.24
1.23
2.13
2.23
+4
2.Y1
+3
Start inputs
EDM inputs
Output switching elements
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no.
External Protection
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety Monitor in Stainless Steel
2.23
2.24
Freigabe
(Release)
Freigabe
(Release)
+
Freigabe
(Release)
-
+
-
Freigabe
(Release)
+AS I 1–
Sicherheitsmonitor
(Safety Monitor)
Eingänge
(Inputs)
1.Y1 (EDM 1)
2.Y1 (EDM 2)
1.Y2 (Start 1)
2.Y2 (Start 2)
+
-
Start inputs
EDM inputs
Output switching elements
+1
1.14
1.Y1
1.24
+ 2 1.Y2
2.14 2.24
+ASI 1-
Other Fieldbuses/
Master Simulators
2.14
2.13
AS I 1 +PWR- (max. 8 A)
+AS I 2– / 24 V, 0V
+
Price Lists
AS-i Safety
Accessories:
Software ASIMON 3 G2 and AS-i Control Tools with serial cable for AS-i Master/monitor in stainless steel (art. no. BW2071)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 267
Safety Basic Monitor
AS-i Master/Gateways/
Links/Scanner
Safety Basic Monitor
2 (4) local electronical safe outputs
Up to 8 / 4 local safe inputs
• optionally the safe inputs will be used as well as standard inputs and
signal outputs
Safe AS-i outputs are supported
• max. 8 independent AS-i outputs
multiple safe AS-i outputs possible via a single address
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Chip card for storage of configuration data
Protection category IP20
T
Article no.
BW2441
BW2557
AS-i Master integrated
X
-
Integrated power supply decoupling unit
X
-
Connection
COMBICON clamp
AS-i voltage
18 ... 31,6 V
Safety monitor
Safety Basic Monitor
Release circuit
2 channel
Respond delay
Inputs
8 / 4 safe inputs cat. 4
or
8 standard in -and outputs
< 50 ms
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Network connection
between the safe input terminals
max. resistance 150 Ω,
max. cable length 200 m
Outputs
2 (4) output switching elements
semiconductor outputs (output circuits 1 and 2)
max. contact load: 700 mA DC-13 at 24V
Interfaces
USB, Chip card slot
Max. AS-i current consumption
200 mA
AUX voltage
20 ... 30 V (PELV)
Max. AUX current consumption
4 A max.
Voltage of insulation AS-i/AUX
500 V
Supply voltage inputs
of 24 V auxiliary power
Supply voltage outputs
of 24 V auxiliary power
AS-i Safety
Max. output current signal outputs
10 mA each output
Max. output current for OSSD supply
Test pulse
1,4 A (S71)
when output is switched on
minimal distance between 2 test pulses: 250 ms, pulse length to 1 ms
Displays
4 x LEDs yellow (S1, S2, S3, S4)
state of input S1, S2, S3 and S4
4 x LEDs yellow (S5, S6, S7, S8)
state of input S5, S6, S7 and S8
LED red/yellow/green (SM)
Price Lists
LED red/yellow/green (AS-i M)
state of Safety Monitor
state of AS-i Master
-
LED red/yellow/green (O1)
output 1 has switched
LED red/yellow/green (O2)
output 2 has switched
1 button
service
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 268
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Safety Basic Monitor
Applied standards
BW2557
EN 954-1 Kat 4
EN 61 508:2001
EN 62 061:2005
EN ISO 13 849-1:2008
Housing
DIN-rail mounting
Storage temperature
0°C ... +55 °C
Operating temperature
-25°C ... +85 °C
Protection class DIN 60 529
housing IP20
Dimensions (L / W / H in mm)
99 / 22,5 / 114
BW2441
BW2557
S 22 S 21 S 12 S 11
S 42 S 41 S 32 S 31
S 62 S 61 S 52 S 51
S 22 S 21 S 12 S 11
S 42 S 41 S 32 S 31
S 62 S 61 S 52 S 51
S1 S2 S3 S4
S1 S2 S3 S4
S5 S6 S7 S8
S5 S6 S7 S8
O1
O1
SM
O2
MICRO USB
CHIP CARD
MICRO USB
O2
CHIP CARD
AS-i M
SM
S 71 S 72 S 81 S 82
1.14 0 V 1 2.14 0 V 2
ext. out ext. out ext. out ext. out
ext. out ext. out ext. out ext. out
ASI + ASI – AUX+ AUX–
ASI + ASI – AUX+ AUX–
ext. in
ext. in
ext. in
Description
S22, S21, S12, S11
safety input terminal input 1
S42, S41, S32, S31
safety input terminal input 2
S62, S61, S52, S51
safety input terminal input 3
S71, S72, S81, S82
safety input terminal input 4
1.14ext.out
semiconductor output 1
2.14ext.out
semiconductor output 2
0 Vext.out
mass connection for semiconductor output
AS-i+, AS-i-
connection to the AS-i Bus
Micro USB
SET
SET
S 71 S 72 S 81 S 82
1.14 0 V 1 2.14 0 V 2
Clamps
AUX+ext.in, AUX-ext.in
AS-i-Master/Gateways/
Links/Scanner
BW2441
power supply
input
ext. in
Accessories:
• Software ASIMON 3 G2 and AS-i Control Tools (art. no. BW2501, see page 304)
• AS-i Safety 4I/2O Module, 8 / 4 safety inputs and 2 (4) electronical safety outputs in IP20 (art. no. BW2314, see page 279) as
supplementary module
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article no.
• AS-i Speed Monitor (art. no. BW2427, s. page 275) as supplementary module
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
• USB cable for Safety Basic Monitor (art. no. BW2530, see page 304)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 269
Safety Basic Monitor Starter Kit
ty
anti
u
q
ted
t.
Limi
s las
k
c
o
st
hile
w
y
onl
Article no. BW2512
The Safety Basic Monitor (BW2441) is supplied in a suitable case with
•
•
•
•
•
•
1 USB connector cable for Safety Basic Monitor (BW2530)
1 emergency stop button with plug-in-shoe connection (BW2527)
1 24V mains power supply
4 rocker switch
1 screwdriver
Programming software ASIMON and AS-i Control Tools for Safety Monitors and AS-i Masters (BW2501)
More information about the aforementioned articles can be found online at www.bihl-wiedemann.de.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Safety Basic Monitor Starter Kit
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 270
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Monitor
1- or 2- channel release circuits
Meets safety-relevant standards
according to category 4 by EN 954-1
Protection category IP20
Article no. BW1764: AS-i Safety Monitor, advanced monitor, 1 OSSD (release circuit), 40 ms
Article no. BW1765: AS-i Safety Monitor, advanced monitor, 2 OSSD (release circuit), 40 ms
The AS-i Safety Monitor allows the connection of Safety at Work
slaves for safety-relevant tasks.
During intended connection the AS-i Safety Monitor permits the
use of sensor-steered safety devices and further safety parts up
to category 4 by EN 954-1.
Likewise the prescribed emergency stop function can be taken
over by the AS-i Safety Monitor for all not hand-guided machines
and furthermore the dynamic monitoring of the restart and the
contactor control function.
Further the use of extensive logic components is made available.
Also the grouping of AS-i slaves (e.g. to the partial disconnection
of machines) is possible.
Article no.
BW1764
BW1765
Release circuit
1-channel
2-channel
Start delay
< 10 s
Respond delay
< 40 ms
Safety Monitor
advanced monitor
Electrical data
Interface
RS 232
Baud rate
9600 baud, no parity, 1 start bit, 1 stop bit, 8 data bits
approx. 150 mA out of 24 V DC
approx. 45 mA out of AS-i
approx. 200 mA out of 24 V DC
approx. 45 mA out of AS-i
Displays/Buttons
LED green
contacts of the safety outputs (OSSD) are:
out: open
lighting: closed
flashing: delay time is running at stop category 1
LED yellow
lighting: start lock/restart lock active
flashing: external test necessary
LED red
contacts of the safety outputs (OSSD) are:
lighting: open / flashing: error
LED green (POWER)
AS-i voltage OK
LED red (AS-i)
communication error
1 (Service)
AS-i Safety
Button
Housing
Connection
screw terminals
Operating temperature
-20°C … +60°C
Storage temperature
-30°C … +70°C
Housing
housing for DIN-rail mounting
Dimensions (L, W, H)
105 mm, 45 mm, 120 mm
Protection category
Standards
Housing IP20
360 g
450 g
EN 50 295, EN 60 947-5-1, IEC61508 (up to SIL 3), IEC 61 496-1,
EN 610 204-1, EN 1088, EN 418, EN 954-1 (up to category 4)
Accessories:
• Programminng software ASIMON with cable (article no. BW1770)
• Interface cable for connection of the Safety Monitor to the PC (article no. BW1771)
• Interface cable for connection of 2 Safety Monitors (article no. BW1772)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 271
Price Lists
Weight
Other Fieldbuses/
Master Simulators
24 V DC (26,5 … 31,6 V out of AS-i)
Operating voltage
Operating current
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety Monitor
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 272
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Slaves
Characteristics
AS-i Speed Monitor
BW2427
2 indepentent axis, chip card
Speed Monitor head unit and Speed Monitor
for 2 axis
BW2538
prewired complet set, parameterization of the speed 276
via USB, monitoring up to 40 axis with expansion
modules possible
Connecting cable for Speed Monitor
Adapter for Speed Monitor
BW2476
connector-ferrule
BW2477
connector-ferrule
BW2494
plug-plug
BW2497
AMP Mini-I/O connector for e.g. Elau MC-4
AMP Mini-I/O connector for e.g. B+R Acopos Sin
BW2499
P.
275
277
278
Cos Interface
AS-i Safety In-/Output Module
AS-i Safety Output Module
8 / 4 safety inputs and 2 (4) electronical safety
outputs
279
BWU2236
relay output module with diagnostic slave,
1 EDM- and 2 / 1 safety inputs
281
BWU2045
relay output module with diagnostic slave
and 1 EDM input
285
BWU2173
output module with diagnostic slave, 1 EDM input,
3I and 2O
289
BWU2284
2 / 1 safety inputs (2 channels) for floating contacts,
protection category IP67
293
BWU2270
2 / 1 safety inputs (2 channels) for optoelectronic
protective devices, protection category IP67
295
Price Lists
AS-i Safety Input Module (M12)
BW2314
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art. No.
Other Fieldbuses/
Master Simulators
Module
AS-i Safety
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Safety Slaves
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 273
AS-i Safety Slaves
Module
Art. No.
Characteristics
AS-i Safety Input Module
BWU1939
2 / 1 safety inputs (2 channels) for floating contacts,
protection category IP20
Emergency stop and reception
BW2527
emergency stop button with plug-in-shoe connection 298
AS-i Safety OEM Slave
BW2426
with 2 standard outputs, supply out of AS-i,
LED display, potted, with connection line
BW2521
with 2 standard outputs, supply out of AS-i,
LED display, potted, with pin connection
AS-i Substructure Module in IP67
BW1896
with screw terminals
BW1751
with plug-in screw terminals
BW1801
with wiring pins
BW1934
no connection
BW2349
for 4-channel module in 45 mm-housing
BW2350
for 4-channel module in 45 mm-housing, centerline
spacing CNOMO
BW2351
for 8-channel module in 60 mm-housing, centerline
spacing CNOMO
P.
297
299
300
301
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Housing
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 274
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Speed Monitor
Supplied by AS-i and external 24 V
Chip card
Article no. BW2427
The Speed Monitor controls the speed of maximum two axis and
gives a sure signal to the AS-i Bus, when the speed is below a
preset threshold.
Article no.
BW2427
Connection
4-fold COMBICON clamp and 2 AMP
Mini-IO plug connections
safe input slaves: S-0.B.E., ID1=F
diagnostic slaves: S-7.A.5., ID1=7 (default)
18-31,6 V
150 mA
18-30 V
200 mA
500 V
2x encoder
25 Hz-200 kHz
out of AS-i and 24 V external
AS-i voltage present
offline
24 V DC AUX present
OFF = normal mode
state encoder 1 (ENC 1)
safety, low frequency or zero-speed axis 1
safety, low frequency or zero-speed axis 2
state encoder 2 (ENC 2)
EN 62 061:2005 SIL 3
EN 954-1 cat. 4
EN ISO 13 849-1:2008/PLe
Housing
Phoenix-ME-MAX housing
Storage temperature
0°C ... +55 °C
Operating temperature
-25°C ... +85 °C
Tolerable loading referring to humidity according to EN 61 131-2
Protection class DIN 60 529
housing IP20
Dimensions (L / W / H in mm)
99 / 22,5 / 114
ENC 1
ENC 2
S1, S2, S3
CHIP CARD
PRJ
ADDR
rotary encoder 1
rotary encoder 2
function selector switch
chip card
projecting button
address socket
Other Fieldbuses/
Master Simulators
AS-i voltage
Max. AS-i current consumption
AUX voltage
Max. AUX current consumption
Voltage of insulation AS-i/AUX
Inputs
Parameterisation range
for the speed limit
Supply voltage
Displays
LED 1 green (ASI)
LED 2 red (FLT)
LED 3 green (AUX)
LED 4 yellow (CONF)
LED 5 yellow (ST1)
LED 6 yellow (F1)
LED 7 yellow (F2)
LED 8 yellow (ST2)
Applied standards
Terminal assignment
AS-i-
+24V ext In
AS-i+
+ 0V ext In
AS-i Safety
AS-i profile
Connections, switches, chip card
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i Speed Monitor
• Cable: BW2476, BW2477, BW2494
• Adapter: BW2497
• Rotary encoder simulator: BW2506
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 275
Price Lists
Accessories:
Speed Monitor head unit and
Speed Monitor for 2 axis
and
Speed Monitor for 2 axis
Spring-type terminals
Prewired
Article no. BW2538
The article BW2538 consists of the following:
• AS-i Speed Monitor (BW2427)
• Safety Basic Monitor (BW2441)
More information about these articles can be found at www.bihl-wiedemann.de
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Speed Monitor head unit
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 276
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Connecting cable for Speed Monitor
AS-i-Master/Gateways/
Links/Scanner
Connection cable safety Speed Monitor
Connection cable for the connection of rotary encoder
Article no. BW2476: connection cable, 1,5 m, connector-ferrule
Article no. BW2477: connection cable, 5,0 m, connector-ferrule
Article no. BW2494: connection cable, 1,5 m, plug-plug
Achievement
BW2476
BW2477
BW2494
for the connection of rotary encoders, shielded
connector-ferrule
plug-plug
Cable
0,2 mm², 3 pairs, copper alloy
Wire
Casing
Ø 5,89 mm, color: chrome, material: PVC
Resistance cable
78,7Ω/km
Resistance shield
55,8Ω/km
Shield
aluminium polyester
RoHS-complient
Length
Cross section:
yes
1,5 m
5,0 m
1,5 m
Connector
Insertion force
Terminating resistor
Operating voltage
Nominal current
Insulation resistance
1
2
1 B / sin sw
2 B / sin gn
3
4
3 nc
4 nc
5
6
5 A / cos ws
6 A / cos sw
7
8
7 Ub
8 GND
30N/8P max.
50mΩ max.
30 V AC
1A
500MΩ min.
Housing
engineering plastic (UL 94V-0),
surface: complete NI coat
Contacts
Copper alloy
rt
sw
The pairs are always twisted
BW2494
Price Lists
AS-i Safety
BW2476/BW2477
Contacts:
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Application
Other Fieldbuses/
Master Simulators
Art. no.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 277
Adapter for Speed Monitor
AS-i Master/Gateways/
Links/Scanner
Overview adapter for Speed Monitor
Article no. Plug
type
The connection for speed monitoring is led laterally out.
Pole
Pole
connector socket
Output Speed
Monitor
Pin
Sin
Pin
Sin
Pin
Cos
Pin GND Suitable for e.g.
Cos
BW2497
Sub-D
9
9
AMP Mini-I/O
connector
2
1
4
3
9
Elau MC-4
BW2499
Sub-D
15
15
AMP Mini-I/O
connector
3
11
1
9
2
B+R Acopos Sin Cos Interface
Further occupancy possibilities are available on request.
Accessories:
Connecting cable 1,5 m, plug-plug (art. no. BW2494)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
The adapters are designed for attachment between frequency inverter and feedback cable. All pins are wired 1:1.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 278
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety 4I/2O Module, 8 / 4 safety inputs
and 2 (4) electronical safety outputs in IP20
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety 4I/2O Module
AS-i Safety Module with 8 / 4 safety inputs
and 2 (4) electronical safety outputs
Optimal costs for safety in- and outputs on AS-i
Module width of 22.5 mm for optimal use of
space in the service cabinet
Universal module for as many use cases,
optimized for service and commissioning
• If the safety input E2 is not needed, the protection feedback
can optionally connected on E2. The transfer occurs as usual
on the diagnostic slave Diagnoseslave of the safety AS-i outputs.
• No limitation of cable length at safety inputs (the maximum
loop resistance is 150 Ohm).
• 8 / 4 safety inputs for floating contacts, 2 / 1 safety input
optionally for optical protective equipment.
• A secure signal exchange of 2 signals between Safety Monitor and AS-i Safety Module as well as between two AS-i
Safety Modules is possible.
Diagnosis and commissioning:
• LED displays according to other Safety Slaves or to the Monitor.
• Simple selection of AS-i Slaves with the help of two rotary
switches. The adressing occurs, as usual, via an AS-i addressing
device or the AS-i Master.
• Chipcard for the simple exchange.
• Fixed Safety Code series for each AS-i address. Each module
generates by same address programming same code series.
• Fast preprocessing: The response time from the disconnection of the local OSSD input to the shutdown of the output is
optionally less than 5 ms.
Article no.
BW2314
Connection
COMBICON clamp
AS-i profile
safety input slaves: S-0.B.F.0
diagnostic slaves: S-7.A.5.E
AS-i voltage
22 ... 31,6 V
Max. AS-i current consumption
200 mA
AUX voltage
20 ... 30 V (PELV)
Max. AUX current consumption
4 A max.
Voltage of insulation AS-i/AUX
500 V
Inputs
8 / 4 safety inputs for floating contacts
E3 + E4 optionally for optical protective equipment
switching current statical 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Supply voltage inputs
out of 24 V auxiliary power
Input level
10 mA, R < 150 Ohm
Outputs
2 (4) output switching elements (semiconductor)
max. contact load:
0,7 A DC-13 at 30 V
Supply voltage outputs
out of 24 V auxiliary power
Max. output current for OSSD supply
1,4 A
Test pulse
when output is switched on
minimal distance between 2 test pulses: 250 ms, pulse length to 1 ms
Other Fieldbuses/
Master Simulators
• It may be less signals are processed. The module uses only
the necessary AS-i addresses.
AS-i Safety
Article no. BW2314
Technical realisation:
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP20
4 x LEDs yellow (S1, S2, S3, S4)
state of input S1, S2, S3 and S4
4 x LEDs yellow (S5, S6, S7, S8)
state of input S5, S6, S7 and S8
LED green (PWR)
AS-i power supply
LED red (FAULT)
AS-i error LED
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 279
Price Lists
Indicators
AS-i Safety 4I/2O Module, 8 / 4 safety inputs
and 2 (4) electronical safety outputs in IP20
output 1 has switched
LED yellow (O2)
output 2 has switched
Applied standards
EN 954-1 Cat 4
EN 61 508:2001
EN 62 061:2005
EN ISO 13 849-1:2008
Housing
DIN-rail mounting
Storage temperature
0°C ... +55 °C
Operating temperature
-25°C ... +85 °C
Tolerable loading referring to humidity
according to EN 61 131-2
Protection class DIN 60 529
housing IP20
Dimensions (L / W / H in mm)
99 / 22,5 / 114,5
Clamps
Description
S22, S21, S12, S11
safety input terminal input 1
S42, S41, S32, S31
safety input terminal input 2
S62, S61, S52, S51
safety input terminal input 3
S1 S2 S3 S4
S71, S72, S81, S82
safety input terminal input 4
S5 S6 S7 S8
1.14ext.out
semiconductor output 1
2.14ext.out
semiconductor output 2
0 V 1ext.out,
0 V 2ext.out
mass connection for semiconductor output
AS-i+, AS-i-
connection to the AS-i-Bus
ADDR
address socket
AUX+ext.in
AUX-ext.in
power supply
input
S 22 S 21 S 12 S 11
S 42 S 41 S 32 S 31
S 62 S 61 S 52 S 51
FAULT
O1
PWR
BCD
67
0
F 12
CHIP CARD
0
67
BCD
E
8 9A
SEL2
F 12
8 9A
SEL1
O2
E
345
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW2314
LED yellow (O1)
345
AS-i Master/Gateways/
Links/Scanner
Article no.
ADDR
ASI + ASI – AUX+ AUX–
0
6
7 8 9A
0
0
8 9A
67
0
7 8 9A
6
345
345
8 9A
POS
Acceptation
0-0
RUN
1-1
addressing Safety Input 1
2-2
addressing Safety Input 2
3-3
addressing Safety Input 3, contacts
4-4
addressing Safety Input 4, contacts
5-5
addressing Safety Input 3, OSSD
(see manual for details)
6-6
addressing Safety Input 4, OSSD
(see manual for details)
7-7
addressing Safety Output 1
8-8
addressing Safety Output 1, diagnostic
9-9
addressing Safety Output 2
A-A
addressing Safety Output 2, diagnostic
D-D
reset to factory defaults
345
Price Lists
12
12
67
BCD
EF
EF
AS-i Safety
12
12
BCD
Addressing
BCD
EF
BCD
ext. in
345
ext. in
EF
Other Fieldbuses/
Master Simulators
S 71 S 72 S 81 S 82
1.14 0 V 1 2.14 0 V 2
ext. out ext. out ext. out ext. out
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 280
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Relay Output Module
with Diagnostic Slave,
1 EDM- and 2 / 1 safety inputs
AS-i-Master/Gateways/
Links/Scanner
Safety + standard I/O in one module
Safety relay output with galvanically isolated contact sets,
approved up to 230 V
Additionally 1 EDM input, 2 / 1 safety inputs
EN 954-1 Cat 4, IEC 61 508 SIL 3, EN 13 849-1/PLe Cat 4, EN IEC 62 061 SIL 3
via this same safety address on a AS-i circuit. All AS-i Safety Relay
Output Modules with the same safety address are controlled simultaneously.
In addition to the safety single address the module also supports an
AB-address e.g. used to transmit the states of the standard inputs and
a safety input address.
Article no.
BWU2236
BWU2236: 3 AS-i modules in one housing!
Inputs
1 EDM, diagnostic,
2 / 1 safety inputs (Cat. 4/SIL 3)
Outputs
1 relay
3 A, 24 V, DC-13 or 3 A, 230 V, AC-15
safety
relay
output
Max. resistance
between S 11 - S12; S 21 - S 22
150 Ohm
AS-i profile diagnostic AB slave
S-7.A.E
ID1 Code diagnostic AB slave
5hex (default), value modifiable
AS-i profile safety input
S-7.B.0
ID1 Code safety input
Fhex (default), value modifiable
External device monitoring (EDM)
reference potential over I+, I-
Indicators
2 x LED yellow (S 1, S 2)
INC
1 x LED yellow (R)
release status
1 x LED yellow (1.Y1)
state of EDM input 1.Y1
LED green (PWR)
AS-i voltage ON
LED red (FAULT)
AS-i Fault
LED yellow (OUT)
for definition see table "device colors"
LED red (ALARM)
PLC inidicates alarm
Current input out of AS-i
< 200 mA
Operating voltage
AS-i (30 VDC)
AUX ext. in voltage supply
24 V DC (± 20%)
S 12
S 11
S 22
S 21
I+
1.Y1
safety input
(2 channels)
I–
NC
S 12
S 11
S 22
S 21
BWU2236
I+
1.Y1
I–
ext.out
safety
address
I+
ext.out
ON
SEL
RUN
PRG
S1 S2 R 1.Y1
FAULT
ALARM
PWR
OUT
ADDR
1.13 1.14 1.23 1.24
1.23 1.24
ASI + ASI – AUX+ AUX-
ASI+ ASI- AUX+ AUXext. in
S 12 S 22
NC S 11 S 21 1.Y1
+ + =
1.14
1.13 1.14
state of safety inputs
(S 11 - S 12, S 21 - S 22)
1 diagnosticand 1 EDM
input
ext. in
ext. in
AB address
safety
address
ext. in
2 safety
addresses
+ AB address
AS-i Safety
The stainless steel AS-i Safety Monitor controls the safety relays of
the AS-i Safety Relay Output Module by using a safety AS-i single address. To set the safety AS-i address, the dip-switch has to be in the
ON/PRG position. Addressing can then be accomplished by using an
AS-i addressing device, for example. Several AS-i Safety Relay Output modules can have the same safety address and can be controlled
Other Fieldbuses/
Master Simulators
Article no. BWU2236
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP20
Voltage of insulation
≥ 6 kV
(relay contact for AS-i resp. AUX ext. in)
Current input out of AUX ext. in
< 30 mA
Voltage of insulation AS-i to AUX ext. in ≥ 500 V
max. 100 mA
Price Lists
Current capacity max. I+
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 281
AS-i Master/Gateways/
Links/Scanner
AS-i Safety Relay Output Module
with Diagnostic Slave,
1 EDM- and 2 / 1 safety inputs
Article no.
BWU2236
Applied standards
EN 954-1 Cat 4
IEC 61 508 SIL 3
EN 13 849-1/PLe Cat 4
EN IEC 62 061 SIL 3
Housing
din-rail mounting
Ambient operating temperature
Storage temperature
0°C ... +55 °C
-25°C ... +85 °C
Dimensions (L / W / H in mm)
114 / 22,5 / 99
Protection class DIN EN 60 529
IP20 (only for use in electrical service
rooms / cabinets with minimum IP54
protection suitable)
Diagnostic Slave
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
(Programming instructions (Bit values of the inputs/outputs, AB slave)
Bit AS-i output
Bit AS-i input
O0 1: Alarm LED on
0: Alarm LED off
I0
O1 Parameter P1=1
not used
Parameter P1=0
Diagnostic (for definition see table "device colors")
I1
1: output controlled by safety release
0: inhibits output on irrespective of safety release
O2 not used
I2
O3 inexistent
I3
Parameter P2=0
Parameter P2=1
1: feedback for user:
safety release on
0: feedback for user:
safety release off
1.Y1
Peripheral fault indicates unavailable 24 V ext.
Diagnostic (device colors)
Value
Color
Description
0
green
output on
1
green flashing –
2
yellow
3
yellow flashing –
4
red
output off
5
red flashing
waiting for "reset of error condition"
6
grey
internal error, such as "fatal error"
only via "Power On" on device
all LEDs flashing
7
green/yellow
output released, but not switched on
switching-on by setting of O1
off
restart inhibit
State change
LED "Out"
on
–
auxillary signal 2
1 Hz
–
off
auxillary signal 1
8 Hz
Programming instructions Diagnostic Slave (bit values of the AS-i parameter)
Bit P1
P1=1
safety output controlled by safety release only
P1=0
safety output controlled by output O1 in addition to safety release
P2=1
input 1.Y1 at AS-i bit I 3
P2=0
feedback for user: release on
Bits P0, P3:
not used
Price Lists
AS-i Safety
Bit P2
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 282
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
... received
safety output contact set open
safety output contact set closed
AS-i Parameter
P1=1
O1=1
safety output contact set open
safety output contact set closed
AS-i Parameter
P1=0
O1=0
safety output contact set open
safety output contact set open
AS-i Parameter
P1=0
O1=1
safety output contact set open
safety output contact set closed
Safety input
Programming instructions (bit values of the safety input address)
Bit
AS-i output
Bit
AS-i input
outputs not used
I0,
I1
safety input S 1
I2,
I3
safety input S 2
Peripheral fault indicates cross-connection between the safety inputs.
Operating elements and clamp assignment
1.13
1.14
1.23
1.24
Freigabe
(Release)
S 11
Freigabe
(Release)
F-Logik
(F-Logic)
S 12
I–
ext out
S 12 S 22 ext.out
I+
NC S 11 S 21 1.Y1
ON
SEL
RUN
PRG
S1 S2 R 1.Y1
S 21
FAULT
S 22
PWR
ALARM
Clamps
Description
S11, S12, S21, S22
safety input clamps
1.13, 1.14
safety output contact set 1
1.23, 1.24
safety output contact set 2
I- ext. out
I+ ext. out
reference potential for EDM-/start input (1.Y1)
1.Y1
EDM / start input
AS-i+, AS-i–
AS-i network connection
AUX+ext.in
AUX-ext.in
voltage supply for safety input
(24 VDC ext.)
OUT
ADDR
AS-i +
AS-i
AS-i -
1. Y1
Eingang
(Input)
1.13 1.14 1.23 1.24
ASI + ASI – AUX+ AUXext.In
LEDs
State
ext.In
Signal / Description
no operating voltage
PWR
(green)
operating voltage present, safety-related AS-i address and/or AS-i AB address is „0“
or no 24 V ext. in (auxiliary power)
AS-i Safety
AS-i parameter
(AB slave)
changes the
function of output bit O1
... not received
AS-i Parameter
P1=1 (default)
O1=0
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Safety Relay Output Module, safety release from the AS-i safety monitor...
Other Fieldbuses/
Master Simulators
Release
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety Relay Output Module
with Diagnostic Slave,
1 EDM- and 2 / 1 safety inputs
1 Hz
operating voltage present
AS-i communication OK
no 24 V ext. in (auxiliary power)
no data exchange with AB slave and/or safety-related AS-i address
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 283
Price Lists
FAULT
(red)
AS-i Safety Relay Output Module
with Diagnostic Slave,
1 EDM- and 2 / 1 safety inputs
AS-i Master/Gateways/
Links/Scanner
output relays contacts open
restart inhibit, waiting for the start signal, the output relays switch-on after the start signal
1 Hz
OUT
(yellow)
8 Hz
device is in unlockable error state.
Waiting for "reset of error condition signal". After receiving this signal the device follows up
with normal operation.
output relays contacts closed
AS-i output bit 0 is not set
ALARM
(red)
AS-i output bit 0 is set
the corresponding input is connected
cross-connection at the safety inputs
S1, S2
(yellow)
8 Hz
release not issued
R (yellow)
release issued
S1, S2, R, 1.Y1
(yellow)
LED on
(running light) switch is adjust to ON/PRG position
LED flashing
LED off
In case all LEDs are blinking simultaneously in fast rythm a fatal error has been detected.
This message is reset by a short-run disconnection of the power supply (Power On Reset).
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
the corresponding input is not connected
S1, S2, 1.Y1
(yellow)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 284
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Relay Output Module
with Diagnostic Slave and 1 EDM input
AS-i Safety relay output with galvanically isolated contact sets,
approved up to 230 V
EN 954-1 Cat 4, IEC 61 508 SIL 3, EN 13 849-1/PLe Cat 4, EN IEC 62 061 SIL 3
Protection category IP20
Article no. BWU2045
put Modules with the same safety address are controlled simultaneously.
In addition to the safety single address the module also supports an
AB-address e.g. used to transmit the states of the standard inputs.
To set the AB address of the inputs, e.g. with an AS-i addressing device, the dip-switch has to be in the RUN position.
BWU2045
BWU2045: 2 AS-i modules in one housing!
Inputs
1 diagnostic + 1 EDM
Outputs
1 relay
3 A, 24 V, DC-13 or 3 A, 230 V, AC-15
1 safety relay
output
AS-i profile
S.7.A.E
ID1 Code
5hex (default), value modifiable
External device monitoring (EDM) supplied out of AS-i, approx. 24 V, approx.
10 mA
I–
I1
Indicators
3 x LED yellow (I1, I2, I3)
state of standard inputs I1, I2, I3
1 x LED yellow (1.Y1)
state EDM input 1.Y1
LED green (PWR)
AS-i voltage ON
LED red (FAULT)
AS-i Fault
LED yellow (OUT)
for definition see table "device color"
LED red (ALARM)
PLC inidicates alarm
Operating current
< 200 mA
Current supply of sensors
90 mA
Operating voltage
AS-i (30 VDC)
Voltage of insulation
≥ 6 kV
Applied standards
EN 954-1 Cat 4
IEC 61 508 SIL 3
EN 13 849-1/PLe Cat 4
EN IEC 62 061 SIL 3
Housing
Din-rail mounting
Ambient operating temperature
Storage temperature
1 diagnostic- and
1 EDM input
1.13 1.14
ASI+ ASI–
1.23
NC
1.24
NC
I+
I2
I+
I3
BW2045
I–
I1
I+
1.Y1
+ =
Safety address
AB address
RUN
I+
I2
I+
I3
I+
1.Y1
PRG
I 1 I 2 I 3 1.Y1
FAULT
PWR
ALARM
OUT
ADDR
1.13 1.14 1.23 1.24
ASI + ASI – NC NC
Safety address
+ AB address
0°C ... +55 °C
-25°C ... +85 °C
114 / 22,5 / 99
Protection class DIN EN 60 529
Housing IP20
Price Lists
Dimensions (L / W / H in mm)
Other Fieldbuses/
Master Simulators
Article no.
AS-i Safety
The stainless steel AS-i Safety Monitor controls the safety relays of
the AS-i Safety Relay Output Module by using a safety AS-i single address. To set the safety AS-i address, the dip-switch has to be in the
PRG position. Addressing can then be accomplished by using an AS-i
addressing device, for example. Several AS-i Safety Relay Output
modules can have the same safety address and can be controlled via
this same safety address on a AS-i circuit. All AS-i Safety Relay Out-
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
Safety + standard I/O in one module
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 285
AS-i Master/Gateways/
Links/Scanner
AS-i Safety Relay Output Module
with Diagnostic Slave and 1 EDM input
Diagnostic operation ID1 = 5hex (default)
Programming instructions (Bit values of inputs/outputs Diagnostic Slave)
Bit AS-i output
Bit AS-i input
O0 1: Alarm LED on
0: Alarm LED off
I0
O1 Parameter P1=1
not used
Parameter P1=0
Diagnostic (for definition see table device colors)
I1
1: output controlled by safety release
0: inhibits output on irrespective of safety release
O2 not used
I2
O3 inexistent
I3
1.Y1
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Diagnostic (device colors)
Value
Color
Description
0
green
output on
1
green flashing –
2
yellow
LED "Out"
3
yellow flashing –
4
red
output off
5
red flashing
waiting for "reset of error condition"
6
grey
internal error, such as "fatal error"
only via "Power On" on device
all LEDs flashing
7
green/yellow
output released, but not switched on
switching-on by setting of O1
off
on
–
restart inhibit
auxillary signal 2
1 Hz
–
off
auxillary signal 1
8 Hz
Programming instructions
Programming instructions Diagnostic Slave (bit values of the AS-i parameter)
Bit P1
P1=1
safety output controlled by safety release only
P1=0
safety output controlled by output O1 in addition to safety release
Bits P0, P2, P3:
not used
Release
Other Fieldbuses/
Master Simulators
State change
AS-i Parameter
(Diagnostic
Slave)
changes the
function of output bit O1
AS-i Safety Relay Output Module, safety release from the AS-i safety monitor...
... not received
... received
AS-i Parameter
P1=1 (default)
O1=0
safety output contact set open
safety output contact set closed
AS-i Parameter
P1=1
O1=1
safety output contact set open
safety output contact set closed
AS-i Parameter
P1=0
O1=0
safety output contact set open
safety output contact set open
AS-i Parameter
P1=0
O1=1
safety output contact set open
safety output contact set closed
AS-i Safety
3I standard inputs (instaed of diagnostic) ID1=7hex, or ID1=Fhex
Connection of sensors
Programming instructions (Bit values of inputs/outputs AB-Slave)
Bit AS-i output
Bit AS-i input
O0 1: Alarm LED on
0: Alarm LED off
I0
I1
I1
I2
I2
Parameter P2=0
Parameter P2=1
I3
1: feedback for user:
safety release on
0: feedback for user:
safety release off
O1 Parameter P1=1
not used
Price Lists
O2 not used
O3 inexistent
Parameter P1=0
1: output controlles by safety release
0: inhabits output on irrespective of safety release
I3
1.Y1
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 286
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Relay Output Module
with Diagnostic Slave and 1 EDM input
AS-i-Master/Gateways/
Links/Scanner
Programming instructions
Programming instructions AB slave (bit values of the AS-i parameter)
Bit P2
P2=1
feedback: safety release at AS-i bit I2
P2=0
input I3 at AS-i bit I2
Bit P1
P1=1
safety output controlled by safety release only
P1=0
safety output controlled by output O1 in addition to safety release
Bits P0, P3
not used
AS-i parameter
(AB slave)
changes the
function of output bit O1
... not received
... received
AS-i Parameter
P1=1 (default)
O1=0
safety output contact set open
safety output contact set closed
AS-i Parameter
P1=1
O1=1
safety output contact set open
safety output contact set closed
AS-i Parameter
P1=0
O1=0
safety output contact set open
safety output contact set open
AS-i Parameter
P1=0
O1=1
safety output contact set open
safety output contact set closed
Operating elements and clamp assignment
1.13
1.14
1.23
1.24
Freigabe
(Release)
Freigabe
(Release)
I–
I1
RUN
I+
I2
I+
I3
I+
1.Y1
PRG
I 1 I 2 I 3 1.Y1
F-Logik
(F-Logic)
FAULT
PWR
ALARM
OUT
ADDR
AS-i +
AS-i
Clamps/Switch
Description
I1, I2, I3
standard inputs I1, I2 and I3
1.13, 1.14
safety output contact set 1
1.23, 1.24
safety output contact set 2
I-, I+
supply voltage for inputs (out of AS-i)
1.Y1
EDM / input for electronic device monitoring
AS-i+, AS-i–
AS-i network connection
ADDR
addressing socket
PRG
protective mode not possible. Programming of
safety-related AS-i address enabled
RUN
protective mode possible. Programming of non
safety-related AS-i address enabled
AS-i -
Eingänge
(Inputs)
1.13 1.14 1.23 1.24
ASI + ASI – NC NC
Price Lists
AS-i Safety
I1
I2
I3
1.Y1
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Safety Relay Output Module, safety release from the AS-i safety monitor...
Other Fieldbuses/
Master Simulators
Release
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 287
AS-i Safety Relay Output Module
with Diagnostic Slave and 1 EDM input
AS-i Master/Gateways/
Links/Scanner
LEDs
State
Signal / Description
no operating voltage
operating voltage present, safety-related AS-i address and/or AS-i AB address is „0“
PWR
(green)
1 Hz
operating voltage present
AS-i communication OK
FAULT
(red)
no data exchange with AB slave
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
output relays contacts open
restart inhibit, waiting for the start signal, the output relays switch-on after the start signal
1 Hz
OUT
(yellow)
8 Hz
output relays contacts closed
AS-i output bit A0 is not set
ALARM
(red)
AS-i output bit A0 is set
the corresponding input is not connected
I1, I2, I3, 1.Y1
(yellow)
the corresponding input is connected
(running light) switch is adjust to PRG position
LED on
LED flashing
LED off
In case all LEDs are blinking simultaneously in fast rythm a fatal error has been detected.
This message is reset by a short-run disconnection of the power supply (Power On Reset).
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
device is in unlockable error state.
Waiting for "reset of error condition signal". After receiving this signal the device follows up
with normal operation.
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 288
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Output Module with Diagnostic Slave,
1 EDM input, 3I and 2O
Electronical safety output
Additional 3 standard inputs, 1 EDM input, 2 outputs
EN 954-1 Cat 4, IEC 61 508 SIL 3, EN 13 849-1/PLe Cat 4, EN IEC 62 061 SIL 3
Protection category IP20
Article no. BWU2173
Safety Output Modules with the same safety address are controlled simultaneously.
In addition to the safety single address the module also supports
an AB-address used to transmit the states of the standard inputs
or of the electronic device monitoring (EDM).
Another AB slave is available for diagnostic.
Article no.
BWU2173
BWU2173: 3 AS-i modules in one housing!
Inputs
3 standard, diagnostic + 1 EDM
1 electronic
safety output
Outputs
2 x output switching elements
max. contact load:
0,5 A DC-13 at 30 V
Test pulse
if output is switched on:
1 pulse per second, pulse length 1ms
state of inputs I1, I2 and I3
state of EDM input 1.Y1
AS-i Fault
LED yellow (O1)
output 1 closed
LED yellow (O2)
output 2 closed
Operating current
< 200 mA
Current supply of sensors
100 mA
Operating voltage
AS-i (30 VDC)
Voltage of insulation
≥ 500 V
External supply
24 V ±20%
Applied standards
EN 954-1 Cat 4
IEC 61 508 SIL 3
EN IEC 62 061 SIL 3
EN 13 849-1/PLe Cat 4
Housing
Din-rail mounting
I+
I2
I+
I3
I+
1.Y1
1.14
1.14 0 V
ext. out
2.14
I–
I+
I+
I+
I1
I2
I3
1.Y1
ext. out ext. out ext. out ext. out
ON
RUN
SEL
PRG
I 1 I 2 I 3 1.Y1
FAULT
O2
PWR
O1
ADDR
1.14 0 V 2.14 0 V
0V
ext. out ext. out ext. out ext. out
ext. out
ASI + ASI – AUX+ AUXext. in
ext. in
ext. in
safety
address
AB address
AB address
safety
address
+ 2 AB
address
0°C ... +55 °C
-25°C ... +85 °C
Dimensions (L / W / H in mm)
114 / 25 / 105
Protection class DIN EN 60 529
housing IP20
Weight
150 g
Tolerable loading referring to
impacts and vibrations
according to EN 61 131-2
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 289
Price Lists
Storage temperature
I–
I1
AS-i voltage ON
LED red (FAULT)
Ambient operating temperature
I+
1.Y1
ASI+ ASI- AUX+ AUXext. in
LED green (PWR)
I+
I3
BWU2173
+ + =
Indicators
1 x LEDs yellow (1.Y1)
I+
I2
Diagnostic and
2 outputs
Other Fieldbuses/
Master Simulators
I–
I1
External device monitoring (EDM) supplied out of 24 V, approx. 10 mA
3 x LED yellow (I1, I2, I3)
3 standard
inputs and 1
EDM input
AS-i Safety
The stainless steel AS-i Safety Monitor controls the outputs of the
AS-i Safety Output Module by using a safety AS-i single address.
To set the safety AS-i address, the dip-switch has to be in the
ON/PRG position. Addressing can then be accomplished by using an AS-i addressing device, for example. Several AS-i Safety
Output Modules can have the same safety address and can be
controlled via this same safety address on a AS-i circuit. All AS-i
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
Safety and standard I/O in one module
AS-i Master/Gateways/
Links/Scanner
AS-i Safety Output Module with Diagnostic Slave,
1 EDM input, 3I and 2O
I–
24 V
0V
I1
Freigabe
Freigabe
Eingänge
I1
I2
I3
1.Y1
Ausgänge
F-Logik
ON
RUN
O1
O2
I+
Clamps
I+
I2
I3
1.Y1
SEL
PRG
I 1 I 2 I 3 1.Y1
FAULT
O2
PWR
O1
Description
I1, I2, I3
standard inputs I1, I2 and I3
1.14
semiconductor output 1
1.24
semiconductor output 2
I-, I+
supply voltage for inputs
1.Y1
EDM 1 / input for electronic device
monitoring
AS-i+, AS-i–
AS-i network connection
AUX+ext.in,
AUX-ext.in
voltage supply input
ADDR
AS-i +
AS-i
AS-i -
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
I+
ext. out ext. out ext. out ext. out
1.14 0 V 2.14 0 V
ext. out ext. out ext. out ext. out
ASI + ASI – AUX+ AUXext. in
ext. in
Programming instructions (bit values of inputs/ouputs, 3I standard inputs and 1 EDM input)
Bit AS-i output
Bit AS-i input
O0 not used
I0
I1
O1 not used
I1
I2
O2 not used
I2
I3
O3 inexistent
I3
1.Y1
Peripheral fault indicates overload of the sensor supply.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
Programming instructions (bit values of the diagnostic slave)
Bit
AS-i output
O0
Parameter P1=1
Parameter P1=0
not used
1: output O 1 controlled by safety release
0: inhibits output O 1 on irrespective of
safety release
Parameter P1=1
Parameter P1=0
not used
1: output O 2 controlled by safety release
0: inhibits output O 2 on irrespective of
safety release
O1
Bit
AS-i input
I0
diagnostic (for definition see table device colors)
I1
O2
not used
I2
O3
inexistent
I3
Parameter P2=0
Parameter P2=1
1.Y1
1: feedback for user:
safety release on
0: feedback for user:
safety release off
Peripheral fault indicates unavailable 24 V ext.
Diagnostic (device colors)
Value
Color
Description
0
green
output on
1
green flashing –
2
yellow
3
yellow flashing –
4
red
output off
5
red flashing
waiting for "reset of error condition"
6
grey
internal error, such as "fatal error"
only via "Power On" on device
all LEDs flashing
7
green/yellow
output released, but not switched on
switching-on by setting of O1
off
restart inhibit
State change
LED "Out"
on
–
auxillary signal 2
1 Hz
–
off
auxillary signal 1
8 Hz
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 290
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Programming instructions (bit values of the AS-i parameter, diagnostic slave)
Bit P1
P1=1
safe output controlled by safety release only
P1=0
safe output controlled by output O0=1 and O1=1 in addition to safety release
Bit P2
P2=1
feedback for user: release on AS-i bit I3
P2=0
input 1.Y1 at AS-i bit I3
Bits P0, P3:
not used
AS-i parameter
(AB slave)
changes the
function of
output bit O0
and O1
LEDs
AS-i Safety Output Module, safety release from the AS-i safety monitor
AS-i Parameter
... not received
... received
P1=1 (default)
O0=0
semiconductor output 1 open
semiconductor output 1 closed
P1=1
O0=1
semiconductor output 1 open
semiconductor output 1 closed
P1=0
O0=0
semiconductor output 1 open
semiconductor output 1 open
P1=0
O0=1
semiconductor output 1 open
semiconductor output 1 closed
P1=1 (default)
O1=0
semiconductor output 2 open
semiconductor output 2 closed
P1=1
O1=1
semiconductor output 2 open
semiconductor output 2 closed
P1=0
O1=0
semiconductor output 2 open
semiconductor output 2 open
P1=0
O1=1
semiconductor output 2 open
semiconductor output 2 closed
State
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Release
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety Output Module with Diagnostic Slave,
1 EDM input, 3I and 2O
Signal / Description
PWR
(green)
operating voltage present, safety-related AS-i address and/or AS-i AB address is „0“
or no 24 V ext. in (auxiliary power)
1 Hz
operating voltage present
AS-i communication OK
Other Fieldbuses/
Master Simulators
no operating voltage
no data exchange with at least one AB slave
FAULT
(red)
semiconductor output open
restart inhibit, waiting for the start signal, the semiconductor output switches on after the start signal
O1, O2
(yellow)
AS-i Safety
no 24 V ext. in (auxiliary power)
1 Hz
8 Hz
device is in unlockable error state;
waiting for "reset of error condition signal"; after receiving this signal the device follows up
with normal operation
Price Lists
semiconductor output closed
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 291
AS-i Safety Output Module with Diagnostic Slave,
1 EDM input, 3I and 2O
I1, I2, I3, 1.Y1
(yellow)
the corresponding input is connected
(running light) switch is adjust to ON/PRG position
LED on
LED flashing
LED off
In case all LEDs are blinking simultaneously in fast rythm a fatal error has been detected.
This message is reset by a short-run disconnection of the power supply (Power On Reset).
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
the corresponding input is not connected
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 292
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Input Module (M12), IP67,
for floating contacts
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety Input Module (M12), IP67,
for floating contacts
2 / 1 safety inputs (2 channels) for floating contacts
2 outputs supplied by galvanically isolated 24 V
EN ISO 13 849-1:2008/PLe Cat 4, EN ISO 13 849-2:2008,
EN 62 061 SIL 3, EN 50 295
BWU2284
Connection
M12
AS-i profile
S-7.B.0, ID1=F
AS-i voltage
22 ... 31,6 V
Max. AS-i current consumption
< 80 mA
AUX voltage
24 V (20 ... 30 VDC) (PELV)
Max. AUX current consumption
3 A max.
Inputs
2 / 1 safety inputs (2 channels) for floating contacts
Power supply of inputs
out of AS-i
Input level
10 mA, R < 150 Ohm
Max. cable capacity X1
I/O: max. 15 m
Outputs
2 (4), electronic
Power supply of outputs
out of AUX voltage
Max. output current
1 A per output
Indicator
2 x LED yellow (S1, S2)
state of inputs S1, S2
2 x LED yellow (Out1, Out2)
state of outputs Out1, Out2
LED green (ASI)
AS-i voltage on
LED red (FLT)
AS-i communication error, slave does not participate in the
normal exchange of data, e.g. slave address 0
LED green (AUX)
24 VDC AUX ON
Applied standards
EN ISO 13 849-1:2008/PLe Cat 4
EN ISO 13 849-2:2008
EN 62 061 SIL 3
EN 50 295
Operating temperature
0°C ... +70°C
Storage temperature
-40°C ... +85°C
Protection class DIN EN 60 529
IP67
Programming
(Bit-setting)
Data bit (input via AS-i)
Bit Function
D0 safety input/ S1
D1 safety input/ S1
D2 safety input/ S2
D3 safety input/ S2
Data bit (output via AS-i)
Bit Function
D0 output 1
D1 output 2
D2 not used
D3 not used
Bit-Parameter
Bit Function
P0 - P3 not used
Peripheral fault
a peripheral fault message will
be released
- if a cross connection between
S1 and S2 is detected
- in case of an output overload
Programming:
Address preset 0
alterable via bus master or
programming devices
Other Fieldbuses/
Master Simulators
Article no.
Besides the outputs are short-circuit, overload and pole protected.
The non-safety-related outputs are equipped with an AS-i communication watchdog.
Using the outputs, up to 2 indicator lights can be activated, with the
power being drawn from the separated 24 V.
AS-i Safety
Article no. BWU2284
The AS-i Safety Input Module has 2 / 1 safety inputs and 2 standard
semiconductor outputs. With the help of the AS-i Safety Input Module
it is possible to support applications up to Safety Category 4.
The supply of the safety input is made out of AS-i. The outputs are
powered out of galvanically isolated 24 V auxiliary power.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Protection category IP67
Allowed shock and vibration stress ≤ 15 g, T ≤ 11 ms
10 ... 55 Hz, 0,5 mm amplitude
80 / 45 / 42
Weight
-
Price Lists
Dimensions (L / W / H in mm)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 293
AS-i Safety Input Module (M12), IP67,
for floating contacts
AS-i Master/Gateways/
Links/Scanner
Connections M12
Name/Number
1
2
3
4
5
X1
S1+
S1–
S2+
S2–
nc
X2
S2+
S2–
nc
nc
nc
X3
nc
Out2
0 Vext out
Out1
nc
X4
nc
nc
0 Vext out
Out2
nc
X5
Adressing socket (with protection cap)
Accessories:
• AS-i substructure module for 4-channel module in 45 mm-housing (article no. BW2349, see also page 301 )
• AS-i substructure module (CNOMO) for 4-channel module in 45 mm-housing (article no. BW2350, see also page 301)
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
• Protection caps for not used M12 sockets (article no. BW2368, see also page 186)
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 294
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Input Module (M12), IP 67,
for optoelectronic protective devices
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety Input Module (M12), IP67, for optoelectronic
protective devices
Applications up to category 4/PL e/SIL 3
EN ISO 13 849-1:2008/PLe Cat 4, EN ISO 13 849-2:2008,
EN 62 061 SIL 3, EN 50 295,
EN 61 496, EN 61 131-2
Protection category IP67
Connection
M12
AS-i profile
S-7.B.1, ID1=F
AS-i voltage
26,5 ... 31,6 V
Max. AS-i current consumption
60 mA
AUX voltage
24 V (20 ... 30 VDC) (PELV)
Max. AUX current consumption
5 A max.
Inputs
2 / 1 safety inputs with two channels for OSSDs
Power supply of inputs
out of AUX voltage
Input level
Vin > 11 V for High-Level,
Input current > 2,5 mA at 15 V
OSSD input test pulses
0 ... 50 Hz
OSSD input test pulse width
Uaux ≥ 21,5 V= 0 ... 1 ms test pulses possible
Uaux ≥ 17 V= 0 ... 0,8 ms test pulses possible
Uaux < 17 V= 0 ... 0,6 ms
Start delay
< 22 ms
Outputs
2 (4), electronic
Power supply of outputs
out of AUX voltage
Max. output current
1 A per output
Power supply for external sensor
2 A out of AUX voltage
Indicator
2x LED yellow (S1, S2)
state of input OSSD1, OSSD2
2x LED yellow (Out1, Out2)
state of output Out1, Out2
LED green (ASI)
AS-i voltage ON
LED red (FLT)
AS-i communication error, slave does not participate in the
normal exchange of data, e.g. slave address 0
LED green (AUX)
24 VDC AUX on
Applied standards
EN 61 496
EN 61 131-2
EN ISO 13 849-1:2008/PLe Cat4
EN ISO 13 849-2:2008
EN 62 061 SIL 3
EN 50 295
Operating temperature
0°C ... +70°C
Storage temperature
-40°C ... +85°C
Protection class DIN EN 60 529
IP67
Programming
(Bit-setting)
Data bit (input via AS-i)
Bit Function
D0 safety input/ OSSD1
D1 safety input/ OSSD1
D2 safety input/ OSSD2
D3 safety input/ OSSD2
Data bit (output via AS-i)
Bit Function
D0 output 1
D1 output 2
D2 not used
D3 not used
Parameter bit
Bit Function
P0 - P3 not used
Peripheral fault
a peripheral fault message will
be released
- if AUX voltage is missing
- in case of an output overload
Programming:
Address preset 0
alterable via bus master or
programming devices
Other Fieldbuses/
Master Simulators
BWU2270
AS-i Safety
Article no.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Connectors M12
Dimensions (L / W / H in mm)
80 / 45 / 42
Weight
-
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 295
Price Lists
Allowed shock and vibration stress ≤ 15 g, T ≤ 11 ms
10 ... 55 Hz, 0,5 mm amplitude
AS-i Safety Input Module (M12), IP 67,
for optoelectronic protective devices
AS-i Master/Gateways/
Links/Scanner
Connections M12
Name/
Number
1
2
3
4
5
0 Vext out
OSSD1
shield
X1
24 Vext out OSSD2
X2
24 Vext out
nc
0 Vext out
24 Vext out
shield
X3
nc
Out2
0 Vext out
Out1
nc
X4
nc
nc
0 Vext out
Out2
nc
X5
Adressing socket (with protection cap)
Wiring examples
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
X2
transmitter
M12
X2
24 V ext out
1 24 V ext out
1 24 V ext out
2 not connected
2 not connected
0 V ext out
3 0 V ext out
4 24 V ext out test
3 0 V ext out
Test
4 24 V ext out test
FE
5 shield
24 V ext out
1 24 V ext out
FE
X1
M12
X2
M12
0 V ext out
OSSD1
4 OSSD1
5 shield
laser scanner
OSSD2
3 0 V ext out
OSSD1
4 OSSD1
24 V ext out
2 OSSD2
0 V ext out
3 0 V ext out
5 shield
1 24 V ext out
OSSD2
2 OSSD2
M12
5 shield
X1
receiver
M12
1 24 V ext out
Other Fieldbuses/
Master Simulators
2 not connected
3 0 V ext out
4 24 V ext out test
5 shield
24 V ext out
1 24 V ext out
OSSD2
2 OSSD2
0 V ext out
3 0 V ext out
OSSD1
4 OSSD1
FE
5 shield
X1
M12
transmitter/
receiver
• AS-i substructure module for 4-channel module in 45 mm-housing (article no. BW2349, see also page 301 )
• AS-i substructure module (CNOMO) for 4-channel module in 45 mm-housing (article no. BW2350, see also page 301)
• Protection caps for not used M12 sockets (article no. BW2368, see also page 186)
Price Lists
AS-i Safety
Accessories:
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 296
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Input Module, IP20,
for floating contacts
2 (4) outputs supplied out of galvanical separated 24 V
Applications up to category 4
Protection category IP20
Article no. BWU1939
puts
are
short-circuit-protected,
inverse-polarity protected.
overload-proof
and
If the bus communication is interrupted, the outputs are switched
to their de-energised state by the watchdog.
Using the outputs, you can drive up to 2 indicator lights, with the
power being drawn from the separated 24 V.
.
Article no.
BWU1939
Programming (Bit-setting)
Inputs
2 / 1 safety inputs (2 channels) for floating contacts
Current input out of AS-i
< 80 mA
Data bit
(input via AS-i)
Bit Function
D0 Safe input S1/Output A1
D1 Safe input S1/Output A2
D2 Safe input S2
D3 Safe input S2
Current input out of 24 V
1,5 A at output short-circuit
Voltage range AS-i
22 ... 31,6 V
Voltage range 24 V
24 V (20 ... 30 V DC) (PELV)
Outputs
2 (4), digital, short-circuit-protected
Loading capacity of outputs
max. 100 mA per output
Length of connector cable
I/O: max. 15 m
Max. resistance of the switches 200 Ohm
Indicator
LED green (Pwr)
AS-i voltage
LED red (Fault)
red: communication fault or address is 0
red, flashing: overload, internal input supply or outputs
LED green (UAux)
voltage supply 24 V ext.
LED red (CC)
cross connection at input lines, peripheral fault
2x LED yellow
safe inputs
2x LED yellow
outputs
Operating voltage
via AS-i
Applied standards
EN 61 000-6-2,
EN 61 000-6-4
EN ISO 13 849-1:2008/PLe Cat 4
EN ISO 13 849-2:2008
EN 62 061 SIL 3
EN 954-1 Cat 4
Operating temperature
0°C ... +70°C
Storage temperature
-40°C ... +70°C
Parameter bit
Bit Function
P0 not used
P1 not used
P2 not used
P3 not used
Programming:
Address preset 0
changeable via bus master or
programming devices
IO-Code 7
ID-Code B
ID2-Code 0
AS-i Safety
The AS-i Safety Slave module has 2 / 1 safety inputs with 2 (4)
standard semiconductor outputs. With the help of the AS-i Safety
Slave it is possible to supply applications up to category 4. The
supply of the safe input is made out of AS-i. The outputs are powered out of galvanical separated 24 V. Besides the in- and out-
Other Fieldbuses/
Master Simulators
2 / 1 safety inputs (2 channels) for floating contacts
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety Input Module, IP20, for floating contacts
Protection category (EN 60 529) IP20
≤ 15 g, T ≤ 11 ms
10 ... 55 Hz, 0,5 mm amplitude
Dimensions (L / W / H in mm)
99,6 / 22,5 / 50,5
Price Lists
Allowable shock and vibration
stress
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 297
AS-i Safety emergency stop button module
AS-i Master/Gateways/
Links/Scanner
AS-i Safety emergency stop button module
Simple assembly concept,
geared to 40 mm profile rail
• timesaving one-hole-screw-fastening technology,
especially suitable for aluminum track rail
Protection class IP65
Article no. BW2527: Emergency stop button with plug-in-shoe connection
Article no.
BW2527
Connection
Installation depth
Contacts
Contact assignment
Shock resistance min.
Mushroom diameter
Life cycle min. (switching cycle)
Applied standards
2,8 x 0,8 mm
27 mm
gold contacts
2Ö
100 N
30 mm
50.000
EN ISO 13 849-1:2008/PLe cat 4
EN ISO 13 849-2:2008
EN 62 061 SIL 3
-25°C ... +70°C
-40°C ... +80°C
IP65 / IP20
according to IEC 60 068-2-3 and 2-30
according to EN 60 068-2-27
according to EN 60 068-2-6
according to IEC 60 068-2-11
60 / 30 / 30
-
Operating temperature
Storage temperature
Protection class (DIN EN 60 529)
Robustness
Shock resistance
Vibration resistance
Environmental stability
Dimensions (L / W / H in mm)
Weight
BW2527
Openings
for 22,3 mm to IEC 60 947-5-1 suitable. All control
elements are equipped with an twisting protection
nose
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW2527
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 298
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety OEM Slave
with 2 standard outputs
Applications up to Safety Category 4 / SIL 3
BW2426
BW521
Safe inputs supplied by AS-i
2 standard outputs supplied out of AS-i with LED’s
90 mm connecting strand
Article no. BW2521: AS-i Safety OEM Slave with 2 standard outputs and contact pins
Article no. BW2426: AS-i Safety OEM Slave with 2 standard outputs
The AS-i Safety OEM Slave meets the requirements of AS-i Safety. With the help of the AS-i Safety OEM Slave it is possible to
supply applications up to Safety Category 4 / SIL 3. The supply
of the safe inputs is made out of AS-i. The standard outputs are
Article no.
BW2426
Connection
90 mm wires
Current input out of AS-i
powered also out of AS-i. Besides the in- and outputs are
short-circuit-protected, overload-proof and pole-protected. If bus
communication is interrupted, the outputs are switched to their
currentless switching state by the watchdog.
BW2521
90 mm wires / contact pins
< 120 mA
Voltage range AS-i
22 ... 31,6 V
Outputs
2, electronic
20 mA per output (total ≤ 40 mA) out of AS-i
Loading capacity of outputs
Length of connector cable
I/O: max. 1, 5 m
Max. resistor of the switches
Programming
(Bit-setting)
200 Ohm
Data bit
(input via AS-i)
Bit Function
D0 Safe input S1/Output A1
D1 Safe input S1/Output A2
D2 Safe input S2
D3 Safe input S2
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Connection of 2 safe switching contacts
AS-i-Master/Gateways/
Links/Scanner
AS-i Safety OEM Slave
LED green
AS-i voltage
2x LED yellow
safe inputs
2x LED yellow
outputs
Operating voltage
via AS-i
EMC directions
EN 61 000-6-2
EN 61 000-6-4
Applied standards
EN ISO 13 849-1:2008/PLe Cat 4
EN ISO 13 849-2:2008
EN 62 061 SIL 3
EN 50 295
Ambient operating temperature
-5°C ... +70°C
Storage temperature
-40°C ... +70°C
Protection category (EN 60 529)
Parameter bit
Bit Function
P0 Not used
P1 Not used
P2 Not used
P3 Not used
Programming:
Address preset 0
changeable via bus master or
programming devices
IO code 7
ID code B
ID2 code 0
IP00 potted
≤ 15 g, T ≤ 11 ms
10 ... 55 Hz, 0,5 mm amplitude
Allowable shock and
vibration stress
Dimensions (L / W / H in mm)
43 / 30 / 10
Signal
BW2426
BW2521
AS-i +
BN
BN
AS-i -
BU
BU
S11, S12
RD, RD
Pin, RD
S21, S22
YE, YE
Pin, RD
O1
WH
WH
O2
GR
GR
0V
BK
Pin, BK
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 299
AS-i Safety
AS-i communication error
Price Lists
LED red
Other Fieldbuses/
Master Simulators
Displays
AS-i Safety OEM Slave
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Safety OEM Slave
Connection of 2 safe switching contacts
Applications up to category 4
Safe inputs supplied by AS-i
Outputs supplied by galvanically isolated 24 V
BW1751
Article no. BW1896 with plug-in screw terminals
Article no. BW1751 with screw terminals
Article no. BW1801 with wiring pins
Article no. BW1934 no connection
The AS-i Safety OEM Slave meets the requirements of AS-i Safety.
With the help of the AS-i Safety OEM Slave it is possible to supply applications up to category 4. The supply of the safe inputs is made out
of AS-i. The outputs are powered out of galvanical separated 24 V.
Besides the in- and outputs are short-circuit-protected, overload-proof and pole-protected.
If bus communication is interrupted, the outputs are switched to their
currentless switching state by the watchdog.
Article no.
Connection
Using the outputs, you can drive up to 2 indicator lights, with the power being drawn from the separated 24 V.
Customer-specific special orders are possible on short notice. The
circuit board dimensions and the plug connections can be changed as
well.
The AS-i Safety OEM Slave offers additionally 2 holes for assembly
angles.
BW1896
BW1751
BW1801
BW1934
plug-in screw
terminals
screw terminals
wiring pins
-
Current input out of AS-i
< 80 mA
Current input out of 24 V
1,5 A at output short-circuit
Voltage range AS-i
22 .. 31,6 V
Voltage range 24 V
24 V (20 .. 30 V DC) (PELV)
Outputs
Programming
(Bit-setting)
Data bit
(input via AS-i)
Bit Function
D0 Safe input S1/Output A1
D1 Safe input S1/Output A2
D2 Safe input S2
D3 Safe input S2
2, electronic, short-circuit-protected
Loading capacity of outputs
max. 100 mA per output
Length of connector cable
Parameter bit
Bit Function
P0 Not used
P1 Not used
P2 Not used
P3 Not used
I/O: max. 15 m
Max. resistor of the switches
200 Ohm
Displays
LED red
error
LED green
power
2x LED yellow
safe inputs
2x LED yellow
outputs
Operating voltage
Programming:
Address preset 0
changeable via bus master or programming devices
via AS-i
EMC directions
EN 61 000-6-2, EN 61 000-6-4
Functional safety
EN 954-1:1996 (up to category 4)
Ambient operating temperature
AS-i Safety
BW1896
IO code 7
ID code B
ID2 code 0
0°C .. +70°C
Storage temperature
-40°C .. +70°C
Protection category (EN 60 529)
IP00
≤ 15 g, T ≤ 11 ms
10 .. 55 Hz, 0,5 mm amplitude
Allowable shock and vibration
stress
Dimensions (L, W, H)
Hint:
The module can not be used with the
OEM carrier board BW1484.
73 mm, 37,5 mm, 12 mm
BW1896
37,6
0V_in
A1
0V
A2
0V
S1+
S1S2+
S2+24V_in
ASIASI+
BW1751, BW1801
6
+24V_in
+24V_in
ASIASIASI+
ASI
SI+
+
d 3,2
1
18
7
3,5
0V
0V_in
+24V_12
A1
E1
0V
A1
A2
0V
0V
E2
nc
A2
nc
0V
S1+
E3
nc
A3
S1
0nc
S2+
E4
nc
NC
S20V
nc V_34
+24
r2
Price Lists
66
19,9
2,54
73
Pwr
IN
Outputs
Safety Inputs Pwr
IN
AS-i
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 300
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Substructure Module in IP67
AS-i-Master/Gateways/
Links/Scanner
AS-i Substructure Module in IP67
BW2349: suitable for mounting on
symmetrical DIN profile rail 35 mm
or for wall-mounting
BW2350 and BW2351:
fixing centres CNOMO compliant;
also suitable for wall mounting
Protection category IP67
BW2351
Article no. BW2349 AS-i Substructure Module for 4-channel module in 45 mm-housing
Article no. BW2350 AS-i Substructure Module (CNOMO) for 4-channel module in 45 mm-housing
Article no. BW2351 AS-i Substructure Module (CNOMO) for 8-channel module in 60 mm-housing
AS-i substructure modules are a necessary accessory for AS-i modules of the product family M12 modules in IP67.
Article no.
BW2349
BW2350
BW2351
Cable
max. 2 yellow AS-i flat cables (AS-i) and 2 black AS-i flat cables (AUX)
simultaneously connectable to the formation of junctions
mounting is possible in two directions
Mounting
2-point
Mounting on symmetrical DIN rail 35 mm
yes
Connection
Weight
4-point
(centerline spacing CNOMO)
no
no
cut clamp terminals (IDC method)
Protection category
Dimensions (L / W/ H in mm)
4-point
(centerline spacing CNOMO)
IP67
81 / 45 / 15
117 / 45 / 10
152 / 60 / 11
45 g
40 g
66 g
Price Lists
AS-i Safety
Substructure modules and appropriate modules:
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW2350
Other Fieldbuses/
Master Simulators
BW2349
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 301
AS-i Substructure Module in IP67
on a 4-channel module:
junctions on a 8-channel module:
normal direction
turned direction
4-channel module:
Dimensions / Encombrements / Abmessungen / Dimensiones / Dimensioni / Dimensões
ASI-FFP.. + ASI-FFB02
45
1.77
7
0.27
3
0.12
3
0.12
33
1.30
5
0.20
3
0.12
3
0.12
37,5
1.48
4,5
0.18
7
0.27
4,5
0.18
7
0.27
80
3.15
107
4.22
42
1.65
=
34
1.34
45
1.77
=
116,5
4.59
mm
in
45
1.77
3 vis/screw M4x3
0,6 N.m
5.2 Lb.in
80
3.15
Other Fieldbuses/
Master Simulators
junctions
Dimensions:
7
0.27
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Wiring examples:
8-channel module:
60
=
40,5
60
34
Price Lists
4,5
4,5
72
72
151
151
34
ASI-FFB03
AS-i Safety
40,5
=
30,5
10,5
33
10,5
12
12
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 302
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Accessories
Art. No.
Characteristics
BW2071
with serial cable for AS-i Master/Monitor in stainless 304
steel
BW2501
for Safety Monitors and AS-i Masters
BW2145
with serial cable for AS-i Master/Monitor in stainless
steel
BW1770
with cable BW1771 and BW1772 only for use with the
Safety Monitors BW1764 and BW1765
Serial cable
BW1575
for AS-i Masters and AS-i Monitors in stainless steel 304
USB connector cable
BW2530
for Safety Basic Monitors
304
Interface cable
BW1771
for connection of the Safety Monitor to a PC
304
Interface cable
BW1772
for connection of 2 Safety Monitors
304
BW2222
memory capacitiy 128 kbyte
305
BW2079
memory capacitiy 32 kbyte
Programming software ASIMON and
AS-i Control Tools
Programming software ASIMON
Price Lists
AS-i Safety
AS-i Chipcard
P.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Module
Other Fieldbuses/
Master Simulators
Housing
AS-i-Master/Gateways/
Links/Scanner
Overview AS-i Safety Accessories
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 303
AS-i Safety Accessories
AS-i Master/Gateways/
Links/Scanner
Software AS-i Safety Monitor
Article no. BW2071
Programming software ASIMON and AS-i Control Tools with serial cable for AS-i Masters/Monitors in stainless steel
Article no. BW2501
Programming software ASIMON and AS-i Control Tools for Safety Monitosr and AS-i Masters
Article no. BW2145
Programming software ASIMON with serial cable for AS-i Masters/Monitors in stainless steel
Article no. BW1770
Programming software ASIMON with cable BW1771 and BW1772
only for use with the Safety Monitors BW1764 and BW1765
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Serial cable for AS-i Masters and AS-i Monitors in stainless steel
Article no. BW1575
Only deliverable in combination with the programming software ASIMON or AS-i Control Tools,
article no. BW2071, BW2145, BW1602
Connection
D-sub data cable 9-pin,
Mini-DIN plug 6-pin
Length
1,8 m
USB connector cable for Safety Basic Monitor BW2441
Article no. BW2530
Connection
USB type A – Micro USB
Length
2m
Colour
black
Other Fieldbuses/
Master Simulators
Interface cable for connection of the Safety Monitor to the PC
Article no. BW1771
Only deliverable in combination with the programming
software ASIMON, article no. BW1770
Connection
RS 232 interface
Length
2m
Interface cable for connection of two Safety Monitors
Article no. BW1772
Connection
2 x RJ45
Length
0,1 m
Price Lists
AS-i Safety
Only deliverable in combination with the programming
software ASIMON, article no. BW1770
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 304
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
AS-i Safety Accessories
Article no.
BW2079
Memory capacity
32 kByte
Weight
128 kByte
ca. 1 g
Dimensions (L / W / H in mm)
Accessories for the following
devices
BW2222
25 / 15 / 1
BWU2044
BWU2186
BWU2027
BWU2187
BWU2109
BWU2188
BWU2000
AS-i-Master/Gateways/
Links/Scanner
Chip card for Bihl+Wiedemann AS-i products
BWU2001
BWU2002
BWU2003
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU2004
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 305
Standard Price List
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Gateways
Article
Art.-No.
Price/Piece
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel
BWU1567 EUR
509.00
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, Class 1 Div. 2
BWU1653 EUR
709.00
AS-i/PROFIBUS DP Gateway in Stainless Steel, without RS232
diagnostics interface, without recognition of duplicate AS-i addresses
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 Masters
BWU1773 EUR
377.00
BWU1568 EUR
677.00
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 Masters,
Class 1 Div. 2
AS-i/PROFIBUS DP Gateway in Stainless Steel, 2 Masters, without
RS 232 diagnostics interface, without recognition of duplicate AS-i
addresses
AS-i 3.0 PROFIBUS DP Gateway, in Stainless Steel 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits
AS-i 3.0 PROFIBUS DP Gateway, in Stainless Steel 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, Basic Master
BWU1654 EUR
BWU1746 EUR
295.00
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel with decoupling coils
BWU1891 EUR
529.00
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 1 AS-i Master,
PROFIBUS slave, Ethernet diagnostics interface
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 AS-i Master,
PROFIBUS slave, Ethernet diagnostics interface
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 1 AS-i Master,
PROFIBUS slave, Ethernet diagnostics interface, 1 gateway + 1 AS-i
power supply for 2 AS-i networks
AS-i 3.0 DeviceNet Gateway in Stainless Steel
BWU2544 EUR
AS-i 3.0 DeviceNet Gateway in Stainless Steel, Class 1 Div. 2
BWU1824 EUR
809.00
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters
BWU1819 EUR
790.00
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
BWU1825 EUR
990.00
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
AS-i 3.0 CANopen Gateway in Stainless Steel
BWU1820 EUR
790.00
BWU1826 EUR
990.00
BWU1821 EUR
509.00
BWU1774 EUR
560.00
BWU1569 EUR
690.00
BWU1655 EUR
890.00
BWU2545 EUR
BWU2546 EUR
BWU1818 EUR
609.00
AS-i 3.0 CANopen Gateway in Stainless Steel, advanced temperature
range
AS-i 3.0 CANopen Gateway in Stainless Steel, 2 Masters
BWU2225 EUR
BWU1822 EUR
690.00
AS-i 3.0 CANopen Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits
AS-i 3.0 Modbus Gateway in Stainless Steel
BWU1823 EUR
690.00
BWU1641 EUR
509.00
AS-i 3.0 Modbus Gateway in Stainless Steel, Class 1 Div. 2
BWU1656 EUR
709.00
677.00
AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters
BWU1642 EUR
AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
BWU1657 EUR
877.00
AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits
AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
AS-i 3.0 EtherCAT Gateways in Stainless Steel, 1 master
BWU1643 EUR
690.00
BWU1658 EUR
890.00
BW2162 EUR
490.00
AS-i 3.0 EtherCAT Gateways in Stainless Steel, 2 Masters
BW2163 EUR
690.00
AS-i 3.0 EtherCAT Gateways in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits
AS-i 3.0 Ethernet/IP + Modbus TCP Gateway in Stainless Steel, 1 Master
BW2164 EUR
690.00
BWU2379 EUR
609.00
AS-i 3.0 Ethernet/IP + Modbus TCP Gateway in Stainless Steel, 2 Masters BWU2380 EUR
790.00
AS-i 3.0 Ethernet/IP + Modbus TCP Gateway in Stainless Steel,
2 Masters, Version 1 Gateway, 1 Power Supply for 2 AS-i circuits
790.00
BWU2381 EUR
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 306
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Standard Price List
BWU2238 EUR
790.00
BWU2239 EUR
790.00
AS-i 3.0 Ethernet Gateway in Stainless Steel, Class 1 Div. 2
BWU1659 EUR
796.00
AS-i 3.0 Ethernet Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
BWU1660 EUR
976.00
AS-i 3.0 Ethernet Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
AS-i 3.0 EtherNet/IP Gateway in Stainless Steel, Class 1 Div. 2
BWU1661 EUR
990.00
BWU1834 EUR
809.00
AS-i 3.0 EtherNet/IP Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2 BWU1835 EUR
990.00
AS-i 3.0 EtherNet/IP Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
AS-i 3.0 RS232 Master in Stainless Steel
BWU1836 EUR
990.00
BWU1955 EUR
390.00
Complete Set: AS-i 3.0 Master for Allen-Bradley ControlLogix BWU1488
plus Accessories BW1563
AS-i 3.0 Master for Allen-Bradley ControlLogix
BWU1488 EUR
AS-i 3.0 Master for Allen-Bradley ControlLogix, Class 1 Div. 2
BWU1716 EUR 1045.00
Complete Set: AS-i 3.0 Master for Allen-Bradley CompactLogix and
MicroLogix BWU1416 plus Accessories BW1563
AS-i 3.0 Master for Allen-Bradley CompactLogix and MicroLogix
BW1611 EUR 1090.00
BW1610 EUR
845.00
790.00
BWU1416 EUR
570.00
AS-i/PROFIBUS DP Gateway IP65
BW1253 EUR
439.71
AS-i/PROFIBUS DP Gateway IP65, M12 connector
BW1371 EUR
439.71
AS-i/CC-Link Gateway IP65
AS-i/Modbus Plus Gateway 2.1
BW1435 EUR
506.18
BWU1583 EUR
713.25
AS-i Master Boards
Article
Art.-No.
Price/Piece
AS-i 3.0 Master PCI Board with advanced diagnostics
BW1922 EUR
490.00
AS-i 3.0 Master PCI Board without RS 232 interface, without duplicate
address recognition
AS-i 3.0 Master Compact PCI Board
BW2087 EUR
375.80
BW1911 EUR
980,00
AS-i PC2 (short PC Board)
BW1228 EUR
350.23
AS-i/PC104 Master
BW1229 EUR
350.23
AS-i Master M-Modul
BW1230 EUR
265.87
AS-i Master OEM Modul with option for AS-i chip programming
BW2176 EUR
AS-i Master OEM Modul for use together with the evaluation kit BW1565
BW1670 EUR
218.00
AS-i Master OEM Module for AS-i 3.0 for customer applications
BW1588 EUR
218.00
AS-i Master OEM Module sample for different options
BW1554 EUR
Evaluation Kit for the AS-i Master OEM Module
BW1565 EUR
480.00
Software
Article
Art.-No.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
609.00
AS-i 3.0 PROFINET Gateway in Stainless Steel, 2 Masters, Version
1 Gateway, 1 Power Supply for 2 AS-i circuits
AS-i 3.0 PROFINET Gateway in Stainless Steel, 2 Masters
AS-i-Master/Gateways/
Links/Scanner
Price/Piece
BWU1912 EUR
Other Fieldbuses/
Master Simulators
Art.-No.
AS-i 3.0 PROFINET Gateway in Stainless Steel
Price/Piece
BW1602 EUR
300.00
AS-i Control Tools with serial cable for Allen-Bradley AS-i Master
BW1563 EUR
300.00
AS-i Control Tools
BW1203 EUR
250.00
ASIMON and AS-i Control Tools with serial cable for AS-i Master/Monitor
in Stainless Steel
ASIMON and AS-i Control Tools for Safety Monitors and AS-i Masters
BW2071 EUR
300.00
BW2501 EUR
250.00
AS.i Sim: Programming and Simulation Software for AS-i (Mini-PLC)
BW1902 EUR
590.00
Price Lists
AS-i Control Tools with serial cable for AS-i Master in Stainless Steel
AS-i Safety
Article
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 307
Standard Price List
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Analog Modules
Article
Art.-No.
Price/Piece
AS-i Analog Input Module 2E, 4 ... 20 mA and 0 ... 10 V
BWU1897 EUR
149.00
AS-i Analog Input Module 0-10 V/4-20 mA, 2 channels, IP20
BWU1345 EUR
149.00
AS-i Analog Input Module 0-10 V/4-20 mA, 2 channels, IP20, scale
SIEMENS compatible
AS-i Analog Input Module 0-10 V/4-20 mA, 2 channels, IP20, default
power supply 24V external
AS-i Analog Output Module 0-10 V/4-20 mA, 2 channels, IP20
BWU1447 EUR
149.00
BWU1726 EUR
149.00
BWU1412 EUR
149.00
AS-i Analog Output Module 0-10 V/4-20 mA, 2 channels, IP20, default
power supply 24 V external
AS-i Analog Output Module 2O for ± 10 V, IP20
BWU1727 EUR
149.00
BWU2224 EUR
198.00
AS-i Analog Input Module 4I, 4-20 mA, IP20
BWU1364 EUR
209.50
AS-i Analog Input Module 4I, 0-10 V, IP20
BWU1365 EUR
209.50
AS-i Analog Output Module 4O, 0-20 mA, IP20
BWU1366 EUR
214.50
AS-i Analog Output Module 4O, 0-10 V, IP20
BWU1367 EUR
214.50
AS-i Analog Module 4Pt100 Inputs, IP20
BWU1368 EUR
205.00
AS-i Analog Module 4 thermocouple type J inputs, IP20
BWU1933 EUR
248.00
AS-i Analog Module 4 thermocouple type K inputs, IP20
BWU2243 EUR
248.00
AS-i Analog Input Module 2I, 4-20 mA
BWU1232 EUR
149.00
AS-i Analog Input Module 2I, 0-10 V
BWU1233 EUR
149.00
AS-i Analog Output Module 2A, 0-20 mA
BWU1234 EUR
149.00
AS-i Analog Output Module 2O, 0-10 V
BWU1235 EUR
149.00
AS-i Analog Module 4 Pt100 Inputs
BWU1254 EUR
179.00
AS-i Analog Module 4 Pt1000 Inputs
BWU1509 EUR
179.00
AS-i Analog Module 2 Pt100 Inputs + 2 Relais Outputs
BW1552 EUR
229.00
AS-i Balance Controller, calibration with AS-i Control Tools, IP65
BW2240 EUR
349.00
AS-i Analog Input Module 2I, 4 .... 20 mA, AS-i 3.0 AB Slave, IP65
BWU1893 EUR
128.00
AS-i Analog Input Module 2E, 4 ... 20 mA, AS-i 2.1 AB Slave, IP65
BWU1894 EUR
128.00
AS-i Analog Module 2 Pt100 Inputs, AS-i 3.0 AB Slave, IP65
BWU1895 EUR
128.00
AS-i Analog Module 2 Pt100 Inputs, 2. input via ID1 deactivated, AS-i 3.0
AB Slave, IP65
AS-i Analog Module 2 PT100 inputs, AS-i 2.1 Single Slave, IP65
BWU2086 EUR
128.00
BWU2050 EUR
128.00
AS-i Analog Input Module 2I, 0 … 10 V, AS-i 3.0 AB Slave, IP65
BWU1963 EUR
121.00
AS-i Analog Input Module 2I, 0 … 10 V, AS-i 2.1 AB Slave, IP65
BWU1964 EUR
121.00
AS-i 3.0 Analog Module 1I/1O, 4 ... 20 mA or 0 ... 10 V, 24 V auxiliary on
M12, IP65
AS-i 3.0 Analog Module 1I/1O, 4 ... 20 mA or 0 ... 10 V, supplied out of
AS-i, IP65
AS-i Analog Input Module 4I, 4-20 mA, IP65
BWU1853 EUR
248.00
BWU1917 EUR
248.00
BWU1359 EUR
214.50
AS-i Analog Input Module 4I, 4-20 mA, Siemens format, IP65
BWU2049 EUR
214.50
AS-i Analog Input Module 4I, 0-10 V, IP65
BWU1360 EUR
214.50
AS-i Analog Input Module 4I, 0-10 V, advanced temperature range, IP65
BWU1742 EUR
248.00
AS-i Analog Output Module 4O, 0-20 mA, IP65
BWU1361 EUR
218.00
AS-i Analog Output Module 4O, 0-10 V, IP65
BWU1362 EUR
218.00
AS-i Analog Output Module 4O, 0-20 mA, IP65
BWU1722 EUR
218.00
AS-i Analog Output Module 4O, 0-10 V, advanced temperature range,
IP65
AS-i Analog Module 4Pt100 Inputs for 4 wire sensors, 24 V external on
M12, IP65
AS-i Analog Module 4Pt100 Inputs for 3 wire sensors, 24 V external on
M12, IP65
BWU1736 EUR
248.00
BWU1363 EUR
206.00
BWU2532 EUR
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 308
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Standard Price List
Price/Piece
BW2033 EUR
AS-i OEM Module: 2 analog Inputs, 0 ... 10 V
BW2035 EUR
AS-i OEM Module: 2 analog Inputs, 0 ... 10 V, without wiring pins and
screw terminals
AS-i 2I/2O AB Module
BW2483 EUR
BW1421 EUR
118.33
43.50
AS-i 2I/2O AB Module with screw terminals
BW1443 EUR
45.50
AS-i 2I/2O AB Module without galvanical separation, screw terminal only
on AS-i pins
AS-i 2I/2O AB Module with wiring pin
BW1957 EUR
45.50
BW1444 EUR
45.50
AS-i 2I/2O AB Module with Fault LED output
BW1490 EUR
AS-i 4I/3O AB Module with wiring pin
BW1386 EUR
53.69
AS-i 4I/3O AB Module with screw terminals
BW1387 EUR
56.24
AS-i 4I/3O AB Module without screw terminals, without wiring pins
BW1408 EUR
AS-i 4I/3O AB Module with plug-in connector
BW2229 EUR
AS-i 4I/4O Module with wiring pin
BW1218 EUR
53.69
AS-i 4I/4O Module with screw terminals
BW1219 EUR
56.24
AS-i 4I/4O Module without screw terminals, without wiring pins
BW1407 EUR
AS-i 4I/4O OEM Module with screw terminals
BW1628 EUR
AS-i 4I/4O OEM Module with wiring pins
BW2054 EUR
AS-i 4I/4O Module, galvanical separated, with wiring pin
BW1388 EUR
53.69
AS-i 4I/4O Module, galvanical separated, with screw terminals
BW1389 EUR
56.24
AS-i 4I/4O Module, galvanical separated, without wiring pins, without
screw terminal
AS-i 4I/4O Module with LEDs
BW1910 EUR
AS-i 4I/4O Module with LEDs with wiring pin
BW1469 EUR
BW1468 EUR
AS-i 4I/4O Module with LEDs with screw terminals
BW1470 EUR
AS-i 4I/4O Module with LEDs with screw terminals, lacquered
BW1789 EUR
AS-i 6I AB Module with screw terminals
BW1627 EUR
AS-i 6I AB Module with screw terminals, turned 180 degrees
BW1679 EUR
59.00
59.00
59.00
97.15
AS-i 8I Module with wiring pin
BW1351 EUR
94.59
AS-i 8I Module with screw terminals
BW1352 EUR
97.15
AS-i 8I/8O OEM Module, 2 4I/4O Single Slave
BW1898 EUR
86.00
AS-i 3.0 8I/8O OEM Module, 2 4I/4O-AB Slave
BW1899 EUR
AS-i 16I/16O OEM Module, 4 4I/4O Single Slave
BW1900 EUR
AS-i 3.0 16I/16O OEM Module, 4 4I/4O-AB Slave
BW1901 EUR
AS-i OEM Slave with serial interface
146.00
EUR
BW1485 EUR
109.00
Price Lists
AS-i Safety
AS-i OEM Power Supply Module
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art.-No.
Other Fieldbuses/
Master Simulators
Article
AS-i OEM Module: 2 analog Inputs, 4 ... 20 mA
AS-i-Master/Gateways/
Links/Scanner
OEM Modules
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 309
Standard Price List
AS-i Master/Gateways/
Links/Scanner
Specialities
Article
128.00
AS-i 4I/4O Relay Module with addressing socket, Single Slave
BW1926 EUR
128.00
AS-i 4I/4O Module with addressing socket, AB Slave
BW1907 EUR
128.00
AS-i 8I Module with addressing socket, AB Slave
BW2077 EUR
128.00
AS-i 8O Module with addressing socket, AB Slave
BW2078 EUR
128.00
AS-i Analog Module, 2 inputs Pt100 + 4 digital inputs/outputs in IP67 (M12)
BW2313 EUR
248.00
BW1931 EUR
460.00
AS-i 3.0 Universal Module in IP65
AS-i Counter Module: 2 channel input
BWU2218 EUR
AS-i Counter Module: 2 x 2 channel input
BWU2219 EUR
AS-i Counter Module: 4 x 2 channel input
BWU2189 EUR
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW1723 EUR
AS-i Counter Module: 1 channel input (0 to 15)
BW1711 EUR
AS-i Code Block with 2 code switches
BW1527 EUR
AS-i Analog Module: 2 inputs for Leuze ODSL 30 Distance Sensors, 0...
65 m
AS-i Analog Module: 2 inputs for Leuze ODSL 30 Distance Sensors, 0...
30 m
AS-i/AS-i Coupler
BW1908 EUR
BW1187 EUR
113.12
AS-i/AS-i Coupler IP65
BW1280 EUR
140.61
138.00
BW1664 EUR
Drive Solutions with AS-i
Article
Art.-No.
Price/Piece
Cylindrical AS-i Actuator 1I/3O
BW1647 EUR
80.78
AS-i Slave for SEW Frequency Inverters (M12), special wiring of the two
inputs, IP65
AS-i 3.0 4I/4O Module for MOVI-SWITCH
BW2038 EUR
139.00
BW2437 EUR
98.00
AS-i 3.0 Motor Module for 2 Roller Drives, speed setting of AS-i parameter
Other Fieldbuses/
Master Simulators
Price/Piece
BW1808 EUR
AS-i Counter Module: 1 channel input (analog)
AS-i 3.0 Motor Module for 2 Roller Drives, speed setting of AS-i analog
values or rotary switch
BW2398 EUR
98.00
BWU2478 EUR
159.00
AS-i Building Automation
Article
AS-i EnOcean Slaves, housing: white, AB Slave
AS-i EnOcean Slaves, housing: black, AB Slave
AS-i Module for controlling damper actuators
AS-i Module for controlling damper actuators, meets requirements for
Switzerland (JGBSK)
AS-i Module for controlling 230 V blinds
AS-i 4I OEM Module for building services engineering
AS-i 2I/2O OEM Module for building services engineering
AS-i 4I/4O Module for building services engineering, AB Slave
AS-i 4O Module for building services engineering, Single Slave
AS-i 4I/3A Module for building services engineering, AB Slave
AS-i 4I/4O Module for building services engineering, Single Slave
AS-i 4I Module for building services engineering, Single Slave
AS-i MP Bus Gateway
Art.-No.
BW2375
BW2473
BW2028
BW2080
BW2114
BW2388
BW2389
BW2137
BW2138
BW2139
BW2175
BW2466
BW2406
Price/Piece
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
Price Lists
AS-i Safety
Art.-No.
AS-i 4I/3O Relay Module with addressing socket, AB Slave
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 310
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Standard Price List
Price/Piece
BW1415 EUR 1300.00
AS-i Programming Device with Plugin Recharger 230 V
BW1191 EUR
AS-i Programming Device with Plugin Recharger 115 V
BW1646 EUR
AS-i addressing cable - infrared addressing adapter
BW1935 EUR
Connecting cable (Module/programming device)
BW1802 EUR
Repeater/AS-i Tuner/AS-i Bus Ternmination
Article
Art.-No.
Price/Piece
AS-i Diagnostic Tuner
BWU1843 EUR
AS-i Tuner
BWU1648 EUR
425.00
325.00
AS-i Bus Termination
BWU1644 EUR
51.00
Advanced Repeater with bus termination, IP20
BWU2192 EUR
229.00
Advanced Repeater, IP20
BWU1855 EUR
193.00
AS-i Repeater, IP65
BWU1273 EUR
193.00
BW2384 EUR
290.00
AS-i High Power Repeater
Power Supply
Article
Art.-No.
Price/Piece
AS-i Power Supply 1,8 A
BW2255 EUR
109.00
AS-i Power Supply 4 A, wide range power supply
BW1649 EUR
168.00
AS-i Power Supply 8 A, power supply with range switch
BW1997 EUR
268.00
AS-i Wide Range Power Supply 8 A
BW2276 EUR
325.00
24 V to 30 V AS-i Power Supply in Stainless Steel 2 A
BW1760 EUR
197.00
8 A Power Supply for AS-i Master in Stainless Steel in Version 1 Power
Supply for 2 AS-i circuits
4 A Power Supply with 3 Phases for AS-i Master in Stainless Steel
BW1593 EUR
238.00
BW1927 EUR
198.00
8 A Power Supply with 3 Phases for AS-i Master in Stainless Steel
BW1676 EUR
325.00
AS-i Power Supply Decoupling Unit: Supply 2 AS-i networks via 1 power
supply
AS-i Power Extender 2,8 A
BW1943 EUR
109.00
BW1197 EUR
116.57
AS-i Power Extender 2,8 A, Class 1 Div. 2
BW1713 EUR
216.57
AS-i Power Extender 4,0 A
BW1477 EUR
116.57
BW1714 EUR
216.57
AS-i Module for Power Decoupling
BW2387 EUR
139.00
Price Lists
AS-i Safety
AS-i Power Extender 4,0 A, Class 1 Div. 2
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art.-No.
AS-i Analyser Innovation Step 2
Other Fieldbuses/
Master Simulators
Article
AS-i-Master/Gateways/
Links/Scanner
Diagnostics/Commissioning
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 311
Standard Price List
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Profile Cables/Passive Distributors/Substructure Modules/ Accessories
Article
Art.-No.
Price/Piece
AS-i Profile Cable yellow, 100 m
BW1979 EUR
275.00
AS-i Profile Cable black, 100 m
BW1980 EUR
295.00
Passive Distributor AS-i on M12
BW1239 EUR
9.00
Passive Distributor AS-i/24 V on M12
BW1976 EUR
19.00
Passive Distributor AS-i on M12, 2 m line
BW1977 EUR
13.25
Passive Distributor AS-i/24 V on M12, 2 m line
BW1974 EUR
21.25
Passive Distributor AS-i flat cable branch
BW1975 EUR
9.80
AS-i Substruture Module to connect 2 AS-i flat Cables
BW1180 EUR
11.00
AS-i Substruture Module to connect 2 AS-i flat Cables with addressing
socket
AS-i Substruture Module to connect 1 AS-i flat cable, 1 flat cable for
additional supply with addressing jack
AS-i Substruture Module to connect 1 AS-i flat Cable, 1 flat Cable for
additional supply
AS-i Substruture Module to connect 2 AS-i round Cables
BW1438 EUR
14.00
AS-i Substruture Module to connect 1 AS-i round Cable, 1 round Cable for
additional supply
Lid for standard AS-i substructure modules
BW1439 EUR
BW1181 EUR
13.00
BW1182 EUR
11.00
BW1183 EUR
14.00
BW1946 EUR
4.80
AS-i ribbon cable seal for PG11 fittings (items per unit: 50)
BW1945 EUR
19.00
AS-i Cable-Stripper
BW1920 EUR
35.00
AS-i Micro-Wire-Stripper
BW1921 EUR
69.95
D-Sub data transmission cord for AS-i Master in IP65, length: 1,5m
BW1097 EUR
34.26
D-Sub data transmission cord 9-pins length: 1,8m
BW1058 EUR
9.71
D-Sub data transmission cord for AS-i Gateways with CAN interface
BW1226 EUR
34.26
19.00
AS addressing cable with COMBICON connector
BW2324 EUR
AS addressing cable with infrared addressing adapter
BW1935 EUR
Connecting cable (Module/programming device)
BW1802 EUR
Protection cap for not used M12 sockets
BW2368 EUR
Reduction sleeve Stainless Steel
BW1241 EUR
9.97
Reduction sleeve M25/M18x1
BW1282 EUR
7.67
Cross-Link Cable for AS-i/Ethernet Gateway
BW1304 EUR
13.80
AS-i Probe
BW1745 EUR
187.00
Chip card for Bihl+Wiedemann AS-i products, memory capacity 32 kByte
(packaging unit: 10 pieces)
Chip card for Bihl+Wiedemann AS-i products, memory capacity 128 kByte
(packaging unit: 10 pieces)
BW2079 EUR
50.00
BW2222 EUR
90.00
Development/Manufacturing of AS-i Components
Art.-No.
Price/Piece
AS-i 3.0 Function and EMC-Test Master, with Master RS 232 (for AS-i
specification 3.0)
AS-i 3.0 SAP4, SAP5, A²SI and ASI4U Programming and Test Tool:
Compact PCI Board
AS-i 3.0 SAP4, SAP5, A²SI and ASI4U Programming and Test Tool: PCI
Board
AS-i Slave Board on basis ASI-SW+
BW1728 EUR 1100.00
AS-i Slave Board on basis A²SI
BW1190 EUR
BW1783 EUR
BW2061 EUR 1100.00
BW1423 EUR
Price Lists
AS-i Safety
Article
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 312
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Standard Price List
Article
Art.-No.
Price/Piece
PROFIBUS DP Master Simulator, PROFIBUS UART
BW1131 EUR
199.00
PROFIBUS DP Master Simulator DP V1
BW1257 EUR
409.00
Serial PROFIBUS DP Master
BW1258 EUR
509.00
DeviceNet Master Simulator with USB interface
BW1420 EUR
559.00
DeviceNet Master Simulator as PCI Board
BW1625 EUR
495.00
CANopen Master Simulator with USB interface
BW1453 EUR
599.00
RS 232C/RS 485 Converter (for Windows) (B+W)
BW1094 EUR
47.55
USB – RS 232 Interface Converter
BW2274 EUR
27.90
AS-i-Master/Gateways/
Links/Scanner
Master Simulators
Other Fieldbusses
Art.-No.
Price/Piece
PROFIBUS Option Board (straight)
BW1261 EUR
PROFIBUS Option Board (crooked)
BW1271 EUR
CAN/PROFIBUS Coupler
BW1246 EUR
CANrho/PROFIBUS Coupler
BW1184 EUR
639.11
CAN/Interbus Coupler, InterBus baud rate 500 KBaud / 2 MBaud,
10 words
CAN/Interbus Coupler, InterBus baud rate 500 KBaud / 2 MBaud,
1-12 words
BW1323 EUR
850.50
BW2504 EUR
850.50
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
455.05
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 313
Standard Price List
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
AS-i Safety
Article
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, 4 independent output switching elements, RS 232
diagnostics interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, power supply decoupling unit, 4 ndepentent output
switching elements, RS 232 diagnostics interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output
switching elements, Ethernet diagnostics interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, 4 independent output switching elements, RS 232
diagnostics interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, power supply decoupling unit, 4 ndepentent output
switching elements, RS 232 diagnostics interface
AS-i 3.0 PROFIBUS DP Gateway with integrated Safety Monitor, 1 AS-i
Master, 16 release circuits, 2 independent output switching elements,
RS 232 diagnostics interface
AS-i 3.0 PROFIBUS DP Gateway with integrated Safety Monitor, 1 AS-i
Master, 16 release circuits, power supply decoupling unit, 2 independent
output switching elements, RS 232 diagnostics interface
AS-i 3.0 PROFIBUS DP Gateway with integrated Safety Monitor, 1 AS-i
Master, 16 release circuits, power supply decoupling unit, 2 independent
output switching elements, Ethernet diagnostics interface
AS-i 3.0 PROFINET Gateway with integrated Safety Monitor, 2 AS-i
Master, 16 release circuits, 4 independent output switching elements,
RS 232 diagnostics interface
AS-i 3.0 PROFINET Gateway with integrated Safety Monitor, 2 AS-i
Master, 16 release circuits, power supply decoupling unit, 4 independent
output switching elements, RS 232 diagnostics interface
AS-i 3.0 PROFINET Gateway with integrated Safety Monitor, 1 AS-i
Master, 16 release circuits, 4 independent output switching elements,
RS 232 diagnostics interface
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway with integrated Safety
Monitor, 2 AS-i Master, 16 release circuits, 4 independent output switching
elements, RS 232 diagnostics interface
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway with integrated Safety
Monitor, 2 AS-i Master, 16 release circuits, power supply decoupling unit,
4 independent output switching elements, RS 232 diagnostics interface
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway with integrated Safety
Monitor, 1 AS-i Master, 16 release circuits, 4 independent output switching
elements, RS 232 diagnostics interface
AS-i 3.0 EtherCAT Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output
switching elements, RS 232 diagnostics interface
AS-i 3.0 EtherCAT Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output
switching elements, RS 232 diagnostics interface
AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 1 AS-i Master, PROFIsafe
for 1 AS-i network, 4 independent output switching elements, RS 232
diagnostics interface
AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 1 AS-i Master, PROFIsafe
for 1 AS-i network, power supply decoupling unit, 4 independent output
switching elements, RS 232 diagnostics interface
AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 2 AS-i Master, PROFIsafe
for 2 AS-i networks, 4 independent output switching elements, RS 232
diagnostics interface
Art.-No.
Price/Piec
BWU2001 EUR 1090.00
BWU2002 EUR 1090.00
BWU2202 EUR 1165.00
BWU2003 EUR
990.00
BWU2004 EUR
990.00
BWU2187 EUR
850.00
BWU2188 EUR
850.00
BWU2206 EUR
925.00
BWU2330 EUR 1290.00
BWU2237 EUR 1290.00
BWU2307 EUR 1190.00
BWU2317 EUR 1290.00
BWU2267 EUR 1290.00
BWU2273 EUR 1090.00
BWU2281 EUR 1090.00
BWU2338 EUR
990.00
BWU2479 EUR
790.00
BWU2434 EUR
BWU2214 EUR 1090.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 314
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
BWU2383 EUR
BWU2205 EUR
690.00
BWU2000 EUR
790.00
BWU2186 EUR
650.00
BW2441 EUR
BW2557 EUR
BW2512
BW1764
BW1765
BW2427
BW2538
BW2476
BW2477
BW2494
BW2497
BW2499
BW2314
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
BW2236 EUR
BW2045
BW2173
BWU2284
BWU2270
BWU1939
366.00
466.00
490.00
39.00
49.00
49.00
249.00
EUR
EUR
EUR
EUR
EUR
225.00
198.00
99.50
99.50
99.50
BW2527 EUR
BW2426 EUR
69.50
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU2421 EUR 1290.00
Other Fieldbuses/
Master Simulators
Art.-No.
Price/Piec
BWU2215 EUR 1090.00
BW1896
BW1751
BW1801
BW1934
BW2349
BW2350
EUR
EUR
EUR
EUR
EUR
EUR
84.00
84.00
84.00
BW2351 EUR
8.95
BW2071 EUR
300.00
BW2501 EUR
BW2145 EUR
250.00
92.50
AS-i Safety
BW2521 EUR
5.95
5.95
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 315
Price Lists
Article
AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 2 AS-i Master, PROFIsafe
for 2 AS-i networks, power supply decoupling unit, 4 independent output
switching elements, RS 232 diagnostics interface
AS-i 3.0 Gateway PROFIsafe via PROFINET, 2 AS-i Master, PROFIsafe
for 2 AS-i networks, 4 independent output switching elements, RS 232
diagnostics interface
AS-i 3.0 Gateway PROFIsafe via PROFINET, 2 AS-i Master, PROFIsafe
for 2 AS-i networks, power supply decoupling unit, 4 independent output
switching elements, RS 232 diagnostics interface
AS-i Safety Monitor in Stainless Steel, Generation II, 16 release circuits,
4 independent output switching elements, Ethernet diagnostics interface
AS-i Safety Monitor in Stainless Steel, Generation II, 16 release circuits,
4 independent output switching elements, RS 232 diagnostics interface
AS-i Safety Monitor in Stainless Steel, Generation II, 16 release circuits,
2 independent output switching elements, RS 232 diagnostics interface
Safety Basic Monitor, AS-i Master disengageable, 8 release circuits,
8 / 4 safe inputs and 2 (4) electronical safe outputs, USB interface
Safety Basic Monitor, 8 release circuits, 8 / 4 safe inputs and
2 (4 electronical safe outputs, USB interface
Safety Basic Monitor Starter Kit
AS-i Safety Monitor, advanced monitor, 1 release circuit, 40 ms
AS-i Safety Monitor, advanced monitor, 2 release circuits, 40 ms
AS-i Speed Monitor
Speed Monitor head unit and Speed Monitor for 2 axis
Connecting cable for Speed Monitor, connector-ferrule
Connecting cable for Speed Monitor, connector-ferrule
Connecting cable for Speed Monitor, plug-plug
Adapter for Speed Monitor
Adapter for Speed Monitor
AS-i Safety 4I/2O Module, 8 / 4 safety inputs and 2 (4) electronical safety
outputs
AS-i Safety Relay In-/Output Module with diagnostic slave, 1 EDM- and
1 safety input
AS-i Safety Relay Output Module with diagnostic slave and 1 EDM input
AS-i Safety Output Module with diagnostic slave, 1 EDM input, 3I and 2O
AS-i Safety Input Module for floating contacts (M12), IP67
AS-i Safety Input Module for optoelectronic protective devices (M12), IP67
AS-i Safety Input Module, 2 / 1 safety inputs (2 channels) for floating
contacts, IP20
Emergency stop button with plug-in-shoe connection
AS-i Safety OEM Slave, with 2 standard outputs, supply out of AS-i, LED
display, potted, with connection line
AS-i Safety OEM Slave, with 2 standard outputs, supply out of AS-i,
LED display, potted, with pin connection
AS-i Safety OEM Slave with plug-in screw terminals
AS-i Safety OEM Slave with screw terminals
AS-i Safety OEM Slave with wiring pins
AS-i Safety OEM Slave
AS-i Substructure Module in IP67 for 4-channel module in 45 mm-housing
AS-i Substructure Module in IP67 for 4-channel module in 45 mm-housing,
centerline spacing CNOMO
AS-i Substructure Module in IP67 for 8-channel module in 60 mm-housing,
centerline spacing CNOMO
ASIMON and AS-i Control Tools with serial cable for AS-i Master/Monitor
in Stainless Steel
ASIMON and AS-i Control Tools for Safety Monitors and AS-i Masters
ASIMON with serial cable for AS-i Masters/Monitors in stainless steel
AS-i-Master/Gateways/
Links/Scanner
Standard Price List
Standard Price List
AS-i Master/Gateways/
Links/Scanner
Article
Programming software ASIMON with cable BW1771 and BW1772 only for
use with the Safety Monitors BW1764 and BW1765
Serial cable for AS-i Masters and AS-i Monitore in stainless steel
USB connector cable for Safety Basic Monitor
Interface cable for connection of the Safety Monitor to a PC
Chip card for Bihl+Wiedemann AS-i products, memory capacity 128 kByte
(packaging unit: 10 pieces)
Chip card for Bihl+Wiedemann AS-i products, memory capacity 32 kByte
(packaging unit: 10 pieces)
Art.-No.
Price/Piec
BW1770 EUR
92.50
BW1575
BW2530
BW1771
BW2222
EUR
EUR
EUR
EUR
79.00
19.00
BW2079 EUR
50.00
90.00
Services
Art.-No.
Price/Piece
AS-i Hotline Service
.
EUR
Development service
.
EUR
135.00
Price · Payment · General Conditions for the Supply of Products and Services
This price list is valid from 28.3.2011 and replaces all previous price lists. The price list is valid until the next
price list will be published.
Net. prices above do not include VAT, packaging or transportation. All orders to be paid within ten days, from
the invoice date.
For all products and services the latest version of the "General Conditions for the Supply of Products and
Services of the Electrical and Electronics Industry (ZVEI)" as well as the added "Retention of Title" are
exclusively in force.
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Article
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 316
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Price List by Article Numbers
11.00
14.00
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
639.11
113.12
116.57
250.00
53.69
56.24
34.26
350.23
350.23
265.87
149.00
149.00
149.00
149.00
9.00
9.97
455.05
439.71
179.00
409.00
509.00
193.00
140.61
7.67
13.80
850.50
149.00
94.59
97.15
214.50
214.50
218.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 317
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
EUR
EUR
Other Fieldbuses/
Master Simulators
Price/Piece
EUR
EUR 135.00
EUR
EUR
9.71
EUR
47.55
EUR
34.26
EUR 199.00
EUR
11.00
EUR
13.00
AS-i Safety
Article
. Development service
. AS-i Hotline Service
AS-i OEM Slave with serial interface
BW1058 D-Sub data transmission cord 9-pins length: 1,8m
BW1094 RS 232C/RS 485 Converter (for Windows) (B+W)
BW1097 D-Sub data transmission cord for AS-i Master in IP65, length: 1,5m
BW1131 PROFIBUS DP Master Simulator, PROFIBUS UART
BW1180 AS-i Substruture Module to connect 2 AS-i flat Cables
BW1181 AS-i Substruture Module to connect 1 AS-i flat Cable, 1 flat Cable for additional
supply
BW1182 AS-i Substruture Module to connect 2 AS-i round Cables
BW1183 AS-i Substruture Module to connect 1 AS-i round Cable, 1 round Cable for
additional supply
BW1184 CANrho/PROFIBUS-Coupler
BW1187 AS-i/AS-i Coupler
BW1190 AS-i Slave Board on basis A²SI
BW1191 AS-i Programming Device with Plugin Recharger 230 V
BW1197 AS-i Power Extender 2,8 A
BW1203 AS-i Control Tools
BW1218 AS-i 4I/4O Module with wiring pin
BW1219 AS-i 4I/4O Module with screw terminals
BW1226 D-Sub data transmission cord for AS-i Gateways with CAN interface
BW1228 AS-i PC2 (short PC Board)
BW1229 AS-i/PC104 Master
BW1230 AS-i Master M-Module
BWU1232 AS-i Analog Input Module 2I, 4-20 mA
BWU1233 AS-i Analog Input Module 2I, 0-10 V
BWU1234 AS-i Analog Output Module 2A, 0-20 mA
BWU1235 AS-i Analog Output Module 2O, 0-10 V
BW1239 Passive Distributor AS-i on M12
BW1241 Reduction sleeve Stainless Steel
BW1246 CAN/PROFIBUS Coupler
BW1253 AS-i/PROFIBUS DP Gateway IP65
BWU1254 AS-i Analog Module 4 Pt100 Inputs
BW1257 PROFIBUS DP Master Simulator DP V1
BW1258 Serial PROFIBUS DP Master
BW1261 PROFIBUS Option Board (straight)
BW1271 PROFIBUS Option Board (crooked)
BWU1273 AS-i Repeater in IP65
BW1280 AS-i/AS-i Coupler IP65
BW1282 Reduction sleeve M25/M18x1
BW1304 Cross-Link Cable for AS-i/Ethernet Gateway
BW1323 CAN/Interbus Coupler, InterBus baud rate 500 KBaud / 2 MBaud, 10 words
BWU1345 AS-i Analog Input Module 0-10 V/4-20 mA, 2 channels, IP20
BW1351 AS-i 8I Module with wiring pin
BW1352 AS-i 8I Module with screw terminals
BWU1359 AS-i Analog Input Module 4I, 4-20 mA, IP65
BWU1360 AS-i Analog Input Module 4I, 0-10 V, IP65
BWU1361 AS-i Analog Output Module 4O, 0-20 mA, IP65
Price Lists
Art. No.
AS-i-Master/Gateways/
Links/Scanner
Price List by Article Numbers
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Price List by Article Numbers
Art. No.
BWU1362
BWU1363
BWU1364
BWU1365
BWU1366
BWU1367
BWU1368
BW1371
BW1386
BW1387
BW1388
BW1389
BW1407
BW1408
BWU1412
BW1415
BWU1416
BW1420
BW1421
BW1423
BW1435
BW1438
BW1439
BW1443
BW1444
BWU1447
BW1453
BW1468
BW1469
BW1470
BW1477
BW1485
BWU1488
BWU1490
BWU1509
BW1527
BW1552
BW1554
BW1563
BW1565
BWU1567
BWU1568
BWU1569
BW1575
BWU1583
BW1588
Article
AS-i Analog Output Module 4O, 0-10 V, IP65
AS-i Analog Module 4Pt100 Inputsfor 4 wire sensors, 24 V external on M12, IP65
AS-i Analog Input Module 4I, 4-20 mA, IP20
AS-i Analog Input Module 4I, 0-10 V, IP20
AS-i Analog Output Module 4O, 0-20 mA, IP20
AS-i Analog Output Module 4O, 0-10 V, IP20
AS-i Analog Module 4Pt100 Inputs, IP20
AS-i/PROFIBUS DP Gateway IP65, M12 connector
AS-i 4I/3O AB Module with wiring pin
AS-i 4I/3O AB Module with screw terminals
AS-i 4I/4O Module, galvanical separated, with wiring pin
AS-i 4I/4O Module, galvanical separated, with screw terminals
AS-i 4I/4O Module without wiring pins, without screw terminals
AS-i 4I/3O AB Module without screw terminals, without wiring pins
AS-i Analog Output Module 0-10 V/4-20 mA, 2 channels, IP20
AS-i Analyser Innovation Step 2
AS-i 3.0 Master for Allen-Bradley CompactLogix and MicroLogix
DeviceNet Master Simulator with USB interface
AS-i 2I/2O AB Module
AS-i Slave Board on basis ASI-SW+
AS-i/CC-Link Gateway IP65
AS-i Substruture Module to connect 2 AS-i flat Cables with addressing socket
AS-i Substruture Module to connect 1 AS-i flat cable, 1 flat cable for additional
supply with addressing jack
AS-i 2I/2O AB Module with screw terminals
AS-i 2I/2O AB Module with wiring pin
AS-i Analog Input Module 0-10 V/4-20 mA, 2 channels, IP20, scale SIEMENS
compatible
CANopen Master Simulator with USB interface
AS-i 4I/4O Module with LEDs
AS-i 4I/4O Module with LEDs with wiring pin
AS-i 4I/4O Module with LEDs with screw terminals
AS-i Power Extender 4,0 A
AS-i OEM Power Supply Module
AS-i 3.0 Master for Allen-Bradley ControlLogix
AS-i 2I/2O AB Module with Fault LED output
AS-i Analog Module 4 Pt100 Inputs
AS-i Code Block with 2 code switches
AS-i Analog Module 2 Pt100-Inputs + 2 Relais Outputs
AS-i Master OEM Module sample for different options
AS-i Control Tools with serial cable for Allen-Bradley AS-i Master
Evaluation Kit for the AS-i Master OEM Module
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 Masters
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits
Serial cable for AS-i Masters and AS-i Monitore in stainless steel
AS-i/Modbus Plus Gateway 2.1
AS-i Master OEM Module for AS-i 3:0 for customer applications
Price/Piece
EUR 218.00
EUR 206.00
EUR 209.50
EUR 209.50
EUR 214.50
EUR 214.50
EUR 205.00
EUR 439.71
EUR
53.69
EUR
56.24
EUR
53.69
EUR
56.24
EUR
EUR
EUR 149.00
EUR 1300.00
EUR 570.00
EUR 559.00
EUR
43.50
EUR
EUR 506.18
EUR
14.00
EUR
EUR
EUR
EUR
45.50
45.50
149.00
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
599.00
59.00
EUR
EUR
EUR
59.00
116.57
109.00
845.00
179.00
138.00
229.00
300.00
480.00
509.00
677.00
690.00
79.00
713.25
218.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 318
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
EUR 1090.00
EUR
EUR
EUR
EUR
EUR
EUR
495.00
97.15
59.00
509.00
677.00
690.00
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
51.00
80.78
325.00
168.00
709.00
EUR
EUR
EUR
709.00
877.00
890.00
EUR
EUR
EUR
796.00
976.00
990.00
890.00
EUR
EUR 218.00
EUR 325.00
EUR
EUR
EUR 216.57
EUR 216.57
EUR 1045.00
EUR 218.00
EUR
EUR 149.00
EUR
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
300.00
790.00
Other Fieldbuses/
Master Simulators
EUR
EUR
AS-i Safety
Price/Piece
EUR 238.00
149.00
EUR 1100.00
EUR
EUR
EUR
EUR
248.00
248.00
187.00
295.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 319
Price Lists
Art. No. Article
BW1593 8 A Power Supply for AS-i Master in Stainless Steel in Version 1 Power Supply for
2 AS-i circuits
BW1602 AS-i Control Tools with serial cable for AS-i Master in Stainless Steel
BW1610 Complete Set: AS-i 3.0 Master for Allen-Bradley CompactLogix and MicroLogix
BWU1416 plus Accessories BW1563
BW1611 Complete Set: AS-i 3.0 Master for Allen-Bradley ControlLogix BWU1488 plus
Accessories BW1563
BW1625 DeviceNet Master Simulator as PCI Board
BW1627 AS-i 6I AB Module with screw terminals
BW1628 AS-i 4I/4O OEM Module with screw terminals
BWU1641 AS-i 3.0 Modbus Gateway in Stainless Steel
BWU1642 AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters
BWU1643 AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits
BWU1644 AS-i Bus Termination
BW1646 AS-i Programming Device with Plugin Recharger 115 V
BW1647 Cylindrical AS-i Actuator 1I/3O
BWU1648 AS-i Tuner
BW1649 AS-i Power Supply 4 A, wide range power supply
BWU1653 AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, Class 1 Div. 2
BWU1654 AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
BWU1655 AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
BWU1656 AS-i 3.0 Modbus Gateway in Stainless Steel, Class 1 Div. 2
BWU1657 AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
BWU1658 AS-i 3.0 Modbus Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
BWU1659 AS-i 3.0 Ethernet Gateway in Stainless Steel, Class 1 Div. 2
BWU1660 AS-i 3.0 Ethernet Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
BWU1661 AS-i 3.0 Ethernet Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
BW1664 AS-i Analog Module: 2 inputs for Leuze ODSL 30 Distance Sensors, 0 ... 30 m
BW1670 AS-i Master OEM Modul for use together with the evaluation kit BW1565
BW1676 8 A Power Supply with 3 Phases for AS-i Master in Stainless Steel
BW1679 AS-i 6I AB Module with screw terminals, turned 180 degrees
BW1711 AS-i Counter Module: 1 channel input (0 to 15)
BW1713 AS-i Power Extender 2,8 A, Class 1 Div. 2
BW1714 AS-i Power Extender 4,0 A, Class 1 Div. 2
BWU1716 AS-i 3.0 Master for Allen-Bradley ControlLogix, Class 1 Div. 2
BWU1722 AS-i Analog Output Module 4O, 0-20 mA, IP65
BW1723 AS-i Counter Module: 1 channel input (analog)
BWU1726 AS-i Analog Input Module 0-10 V/4-20 mA, 2 channels, IP20, default power supply
24 V external
BWU1727 AS-i Analog Output Module 0-10 V/4-20 mA, 2 channels, IP20, default power
supply 24 V external
BW1728 AS-i 3.0 Function and EMC-Test Master, with Master RS 232
(for AS-i specification 3.0)
BWU1736 AS-i Analog Output Module 4O, 0-10 V, advanced temperature range, IP65
BWU1742 AS-i Analog Input Module 4I, 0-10 V, advanced temperature range, IP65
BW1745 AS-i Probe
BWU1746 AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, Basic Master
AS-i-Master/Gateways/
Links/Scanner
Price List by Article Numbers
AS-i Master/Gateways/
Links/Scanner
Price List by Article Numbers
Art. No.
BW1751
BW1760
BW1764
BW1765
BW1770
BW1771
BWU1773
BWU1774
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BW1783
BW1789
BW1801
BW1802
BW1808
BWU1818
BWU1819
BWU1820
BWU1821
BWU1822
BWU1823
BWU1824
BWU1825
BWU1826
BWU1834
BWU1835
BWU1836
BWU1843
BWU1853
BWU1855
BWU1891
BWU1893
BWU1894
BWU1895
BW1896
BWU1897
BW1898
BW1899
BW1900
BW1901
BW1902
BW1907
BW1908
BW1910
Article
AS-i Safety OEM Slave with screw terminals
24 V to 30 V AS-i Power Supply in Stainless Steel 2 A
AS-i Safety Monitor, advanced monitor, 1 release circuit, 40 ms
AS-i Safety Monitor, advanced monitor, 2 release circuits, 40 ms
Programming software ASIMON with cable BW1771 and BW1772 only for use with
the Safety Monitors BW1764 and BW1765
Interface cable for connection of the Safety Monitor to a PC
AS-i/PROFIBUS DP Gateway in Stainless Steel, without RS232 diagnostics
interface, without recognition of duplicate AS-i addresses
AS-i/PROFIBUS DP Gateway in Stainless Steel, 2 Masters, without RS232
diagnostics interface, without recognition of duplicate AS-i addresses
AS-i 3.0 SAP4, SAP5, A²SI and ASI4U Programming and Test Tool: Compact PCI
Board
AS-i 4I/4O Module with LEDs with screw terminals, lacquered
AS-i Safety OEM Slave with wiring pins
Connecting cable (Module/programming device)
AS-i 4I/3O RelayModule with addressing socket, AB Slave
AS-i 3.0 DeviceNet Gateway in Stainless Steel
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits
AS-i 3.0 CANopen Gateway in Stainless Steel
AS-i 3.0 CANopen Gateway in Stainless Steel, 2 Masters
AS-i 3.0 CANopen Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits
AS-i 3.0 DeviceNet Gateway in Stainless Steel, Class 1 Div. 2
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
AS-i 3.0 DeviceNet Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
AS-i 3.0 EtherNet/IP Gateway in Stainless Steel, Class 1 Div. 2
AS-i 3.0 EtherNet/IP Gateway in Stainless Steel, 2 Masters, Class 1 Div. 2
AS-i 3.0 EtherNet/IP Gateway in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits, Class 1 Div. 2
AS-i Diagnostic Tuner
AS-i 3.0 Analog Module 1I/1O, 4 ... 20 mA or 0 ... 10 V, 24 V auxiliary on M12, IP65
Advanced Repeater, IP20
AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel with decoupling coils
AS-i Analog Input Module 2I, 4 ... 20 mA, AS-i 3.0 AB Slave, IP65
AS-i Analog Input Module 2E, 4 ... 20 mA, AS-i 2.1 AB Slave, IP65
AS-i Analog Module 2 Pt100 Inputs, AS-i 3.0 AB Slave, IP65
AS-i Safety OEM Slave with plug-in screw terminals
AS-i Analog Input Module 2E, 4 ... 20 mA and 0 ... 10 V
AS-i 8I/8O OEM Module, 2 4I/4O Single Slave
AS-i 3.0 8I/8O OEM Module, 2 4I/4O-AB Slave
AS-i 16I/16O OEM Module, 4 4I/4O Single Slave
AS-i 3.0 16I/16O OEM Module, 4 4I/4O-AB Slave
AS-i Sim: Programming and Simulation Software for AS-i (Mini-PLC)
AS-i 4I/4O Module with addressing socket, AB Slave
AS-i Analog Module: 2 inputs for Leuze ODSL 30 Distance Sensors, 0 ... 65 m
AS-i 4I/4O Module, galvanical separated, without wiring pins, without screw
terminal
Price/Piece
EUR
84.00
EUR 197.00
EUR 366.00
EUR 466.00
EUR
92.50
EUR
EUR
377.00
EUR
560.00
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
128.00
609.00
790.00
790.00
EUR
EUR
EUR
509.00
690.00
690.00
EUR
EUR
EUR
809.00
990.00
990.00
EUR
EUR
EUR
809.00
990.00
990.00
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
425.00
248.00
193.00
529.00
128.00
128.00
128.00
84.00
149.00
86.00
84.00
146.00
590.00
128.00
128.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 320
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
BWU2001
BWU2002
BWU2003
BWU2004
BW2028
BW2033
BW2035
BW2038
BW2045
BWU2049
BWU2050
BW2054
109.00
19.00
4.80
390.00
45.50
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
EUR
121.00
121.00
21.25
9.80
19.00
13.25
275.00
295.00
268.00
790.00
EUR 1090.00
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
EUR
EUR
EUR
EUR
EUR
Other Fieldbuses/
Master Simulators
BWU1963
BWU1964
BW1974
BW1975
BW1976
BW1977
BW1979
BW1980
BW1997
BWU2000
Price/Piece
EUR 980.00
EUR 609.00
EUR 248.00
EUR
35.00
EUR
69.95
EUR 490.00
EUR 128.00
EUR 198.00
EUR 460.00
EUR 248.00
EUR
EUR
EUR
99.50
EUR 1090.00
EUR
990.00
EUR
990.00
EUR
EUR
EUR
EUR
118.33
139.00
EUR
EUR
EUR
EUR
225.00
214.50
128.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 321
AS-i Safety
BW1943
BW1945
BW1946
BWU1955
BW1957
Article
AS-i 3.0 Master Compact PCI Board
AS-i 3.0 PROFINET Gateway in Stainless Steel
AS-i 3.0 Analog Module 1I/1O, 4 ... 20 mA or 0 ... 10 V, supplied out of AS-i, IP65
AS-i Cable-Stripper
AS-i Micro-Wire-Stripper
AS-i 3.0 Master PCI Board with advanced diagnostics
AS-i 4I/4O RelayModule with addressing socket, Single Slave
4 A Power Supply with 3 Phases for AS-i Master in Stainless Steel
AS-i 3.0 Universal Module in IP65
AS-i Analog Module 4 thermocouple type J inputs, IP20
Module Safety OEM AS-i
AS-i addressing cable with infrared addressing adapter
AS-i Safety Input Module, 2 / 1 safety inputs (2 channels) for optoelectronic
protective devices, IP67
AS-i Power Supply Decoupling Unit: Supply 2 AS-i networks via 1 power supply
AS-i ribbon cable seal for PG11 fittings (items per unit: 50)
Lid for standard AS-i substructure modules
AS-i 3.0 RS232 Master in Stainless Steel
AS-i 2I/2O AB Module without galvanical separation, screw terminal only on AS-i
pins
AS-i Analog Input Module 2I, 0 … 10 V, AS-i 3.0 AB Slave, IP65
AS-i Analog Input Module 2I, 0 … 10 V, AS-i 2.1 AB Slave, IP65
Passive Distributor AS-i/24 V on M12, 2 m line
Passive Distributor AS-i flat cable branch
Passive Distributor AS-i/24 V on M12
Passive Distributor AS-i on M12, 2 m line
AS-i Profile Cable yellow, 100 m
AS-i Profile Cable black, 100 m
AS-i Power Supply 8 A, power supply with range switch
AS-i Safety Monitor in Stainless Steel, Generation II, 16 release circuits,
4 independent output switching elements, RS 232 diagnostics interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, 4 independent output switching elements, RS 232 diagnostics
interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output switching
elements, RS 232 diagnostics interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, 4 independent output switching elements, RS 232 diagnostics
interface
AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output switching
elements, RS 232 diagnostics interface
AS-i Module for controlling damper actuators
AS-i OEM Module: 2 analog Inputs, 4 ... 20 mA
AS-i OEM Module: 2 analog Inputs, 0 ... 10 V, 2 AS-i Master,
AS-i Slave for SEW Frequency Inverters (M12), special wiring of the two inputs,
IP65
AS-i Safety Relay Output Module with diagnostic slave and 1 EDM input
AS-i Analog Input Module 4I, 4-20 mA, Siemens format, IP65
AS-i Analog Module 2 PT100 inputs, AS-i 2.1 Single Slave, IP65
AS-i 4I/4O OEM Module with wiring pins
Price Lists
Art. No.
BW1911
BWU1912
BWU1917
BW1920
BW1921
BW1922
BW1926
BW1927
BW1931
BWU1933
BW1934
BW1935
BWU1939
AS-i-Master/Gateways/
Links/Scanner
Price List by Article Numbers
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Price List by Article Numbers
Art. No. Article
BW2061 AS-i 3.0 SAP4, SAP5, A²SI and ASI4U Programming and Test Tool: PCI Board
BW2071 ASIMON and AS-i Control Tools with serial cable for AS-i Master/Monitor in
Stainless Steel
BW2077 AS-i 8I Module with addressing socket, AB Slave
BW2078 AS-i 8O Module with addressing socket, AB Slave
BW2079 Chip card for Bihl+Wiedemann AS-i products, memory capacity 32 kByte
(packaging unit: 10 pieces)
BW2080 AS-i Module for controlling damper actuators, meets requirements for Switzerland
(JGBSK)
BWU2086 AS-i Analog Module 2 Pt100 Inputs, 2. input via ID1 deactivated, AS-i 3.0 AB Slave,
IP65
BW2087 AS-i 3.0 Master PCI Board without RS 232 interface, without duplicate address
recognition
BW2114 AS-i Module for controlling 230 V blinds
BW2137 AS-i 4I/4O Module for building services engineering, AB Slave
BW2138 AS-i 4O Module for building services engineering, Single Slave
BW2139 AS-i 4I/3A Module for building services engineering, AB Slave
BW2145 Programming software ASIMON with serial cable for AS-i Masters/Monitors in
stainless steel
BW2162 AS-i 3.0 Ethernet Gateways in Stainless Steel, 1 master
BW2163 AS-i 3.0 Ethernet Gateways in Stainless Steel, 2 Masters
BW2164 AS-i 3.0 EtherCAT Gateways in Stainless Steel, 2 Masters, Version 1 Gateway,
1 Power Supply for 2 AS-i circuits
BW2173 AS-i Safety Output Module with diagnostic slave, 1 EDM input, 3I and 2O
BW2175 AS-i 4I/4O Module for building services engineering, Single Slave
BW2176 AS-i Master OEM Modul with option for AS-i chip programming
BWU2186 AS-i Safety Monitor in Stainless Steel, Generation II, 16 release circuits,
2 independent output switching elements, RS 232 diagnostics interface
BWU2187 AS-i 3.0 PROFIBUS DP Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, 2 independent output switching elements, RS 232 diagnostics
interface
BWU2188 AS-i 3.0 PROFIBUS DP Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, power supply decoupling unit, 2 independent output switching
elements, RS 232 diagnostics interface
BWU2189 AS-i Counter Module: 4 x 2 channel input
BWU2192 Advanced Repeater with bus termination, IP20
BWU2202 AS-i 3.0 Profibus Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output switching
elements, Ethernet diagnostics interface
BWU2205 AS-i Safety Monitor in Stainless Steel, Generation II, 16 release circuits,
2 independent output switching elements, Ethernet diagnostics interface
BWU2206 AS-i 3.0 PROFIBUS DP Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, power supply decoupling unit, 2 independent output switching
elements, Ethernet diagnostics interface
BWU2214 AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 2 AS-i Master, PROFIsafe for 2 AS-i
networks, 4 independent output switching elements, RS 232 diagnostics interface
BWU2215 AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 2 AS-i Master, PROFIsafe for 2 AS-i
networks, power supply decoupling unit, 4 independent output switching elements,
RS 232 diagnostics interface
BWU2218 AS-i Counter Module: 2 channel Input
BWU2219 AS-i Counter Module: 2 x 2 channel input
BW2222 Chip card for Bihl+Wiedemann AS-i products, memory capacity 128 kByte
(packaging unit: 10 pieces)
Price/Piece
EUR 1100.00
EUR 300.00
EUR
EUR
EUR
128.00
128.00
50.00
EUR
EUR
128.00
EUR
375.80
EUR
EUR
EUR
EUR
EUR
92.50
EUR
EUR
EUR
490.00
690.00
690.00
EUR
EUR
EUR
EUR
198.00
EUR
850.00
EUR
850.00
650.00
EUR
EUR 229.00
EUR 1165.00
EUR
690.00
EUR
925.00
EUR 1090.00
EUR 1090.00
EUR
EUR
EUR
90.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 322
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
BWU2270
BWU2273
BW2274
BW2276
BWU2281
BWU2284
BWU2307
BW2313
BW2314
BWU2317
BW2324
BWU2330
BWU2338
BW2349
BW2350
BW2351
BW2368
BW2375
BWU2379
BWU2380
EUR
790.00
EUR 790.00
EUR 349.00
EUR 248.00
EUR 109.00
EUR 1290.00
EUR
99.50
EUR 1090.00
EUR
27.90
EUR 325.00
EUR 1090.00
EUR
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
BWU2239
BW2240
BWU2243
BW2255
BW2267
EUR 1290.00
99.50
EUR 1190.00
EUR 248.00
EUR
EUR 1290.00
Other Fieldbuses/
Master Simulators
BWU2238
Price/Piece
EUR 198.00
EUR
EUR
EUR 249.00
EUR
19.00
EUR 1290.00
EUR
990.00
EUR
EUR
5.95
5.95
EUR
8.95
EUR
EUR
EUR
EUR
609.00
790.00
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 323
AS-i Safety
BWU2237
Article
AS-i Analog Output Module 2O for ± 10 V, IP20
AS-i 3.0 CANopen Gateway in Stainless Steel, advanced temperature range
AS-i 4I/3O AB Module with plug-in connector
AS-i Safety Relay In-/Output Modul, with diagnostic slave, 1 EDM- and 2 / 1 safety
inputs
AS-i 3.0 PROFINET Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output switching
elements, RS 232 diagnostics interface
AS-i 3.0 PROFINET Gateway in Stainless Steel, 2 Masters, power supply
decoupling unit
AS-i 3.0 PROFINET Gateway in Stainless Steel, 2 Masters
AS-i Balance Controller, calibration with AS-i Control Tools, IP65
AS-i Analog Module 4 thermocouple type K inputs, IP20
AS-i Power Supply 1,8 A
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway with integrated Safety Monitor, 2 AS-i
Master, 16 release circuits, power supply decoupling unit, 4 independent output
switching elements, RS 232 diagnostics interface
AS-i Safety Input Module, 2 / 1 safety inputs (2 channels) for optoelectronic
protective devices (M12), IP67
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway with integrated Safety Monitor, 1 AS-i
Master, 16 release circuits, 4 independent output switching elements, RS 232
diagnostics interface
USB – RS 232 Interface Converter
AS-i Wide Range Power Supply 8 A
AS-i 3.0 EtherCAT Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output switching
elements, RS 232 diagnostics interface
AS-i Safety Input Module, 2 / 1 safety inputs (2 channels) for floating contacts
(M12), IP67
AS-i 3.0 PROFINET Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, 4 independent output switching elements, RS 232 diagnostics
interface
AS-i Analog Module, 2 inputs Pt100 + 4 digital inputs/outputs in IP67 (M12)
AS-i Safety 4I/2O Module, 8 / 4 safety inputs and 2 (4) electronical safety outputs
AS-i 3.0 EtherNet/IP+Modbus TCP Gateway with integrated Safety Monitor, 2 AS-i
Master, 16 release circuits, 4 independent output switching elements, RS 232
diagnostics interface
AS addressing cable with COMBICON connector
AS-i 3.0 PROFINET Gateway with integrated Safety Monitor, 2 AS-i Master,
16 release circuits, 4 independent output switching elements, RS 232 diagnostics
interface
AS-i 3.0 EtherCAT Gateway with integrated Safety Monitor, 1 AS-i Master,
16 release circuits, power supply decoupling unit, 4 independent output switching
elements, RS 232 diagnostics interface
AS-i Substructure Module in IP67 for 4-channel module in 45 mm-housing
AS-i Substructure Module in IP67 for 4-channel module in 45 mm-housing,
centerline spacing CNOMO
AS-i Substructure Module in IP67 for 8-channel module in 60 mm-housing,
centerline spacing CNOMO
Protection cap for not used M12 sockets
AS-i EnOcean Slaves, housing: white, AB Slave
AS-i 3.0 Ethernet/IP + Modbus TCP Gateway in Stainless Steel, 1 Master
AS-i 3.0 Ethernet/IP + Modbus TCP Gateway in Stainless Steel, 2 Masters
Price Lists
Art. No.
BWU2224
BWU2225
BW2229
BW2236
AS-i-Master/Gateways/
Links/Scanner
Price List by Article Numbers
Art. No. Article
BWU2381 AS-i 3.0 Ethernet/IP + Modbus TCP Gateway in Stainless Steel, 2 Masters,
Version 1 Gateway, 1 Power Supply for 2 AS-i circuits
BWU2383 AS-i 3.0 Gateway PROFIsafe via PROFINET, 2 AS-i Master, PROFIsafe for 2 AS-i
networks, power supply decoupling unit, 4 independent output switching elements,
RS 232 diagnostics interface
BW2384 AS-i High Power Repeater
BW2387 AS-i Module for Power Decoupling
BW2388 AS-i 4I OEM Module for building services engineering
BW2389 AS-i 2I/2O OEM Module for building services engineering
BW2398 AS-i 3.0 Motor Module for 2 Roller Drives, speed setting of AS-i parameter
BW2406 AS-i MP Bus Gateway
BWU2421 AS-i 3.0 Gateway PROFIsafe via PROFINET, 2 AS-i Master, PROFIsafe for 2 AS-i
networks, 4 independent output switching elements, RS 232 diagnostics interface
BW2426 AS-i Safety OEM Slave, with 2 standard outputs, supply out of AS-i, LED display,
potted, with connection line
BW2427 AS-i Speed Monitor
BW2434 AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 1 AS-i Master, PROFIsafe for 1 AS-i
network, power supply decoupling unit, 4 independent output switching elements,
RS 232 diagnostics interface
BW2437 AS-i 3.0 4I/4O Module for MOVI-SWITCH
BW2441 Safety Basic Monitor, AS-i Master disengageable, 8 release circuits, 8 / 4 safe
inputs and 2 (4) electronical safe outputs, USB interface
BW2466 AS-i 4I Module for building services engineering, Single Slave
BW2473 AS-i EnOcean Slaves, housing: black, AB Slave
BW2476 Connecting cable for Speed Monitor, connector-ferrule
BW2477 Connecting cable for Speed Monitor, connector-ferrule
BWU2478 AS-i 3.0 Motor Module for 2 Roller Drives, speed setting of AS-i analog values or
rotary switch
BWU2479 AS-i 3.0 Gateway PROFIsafe via PROFIBUS, 1 AS-i Master, PROFIsafe for 1 AS-i
network, RS 232 diagnostics interface
BW2494 Connecting cable for Speed Monitor, plug-plug
BW2497 Adapter for Speed Monitor
BW2499 Adapter for Speed Monitor
BW2483 AS-i OEM Module: 2 analog Inputs, 0 ... 10 V, without wiring pins and screw
terminals
BW2501 ASIMON and AS-i Control Tools for Safety Monitors and AS-i Masters
BW2504 CAN/Interbus Coupler, InterBus baud rate 500 KBaud / 2 MBaud, 1-12 words
BW2512 Safety Basic Monitor Starter Kit
BW2521 AS-i Safety OEM Slave, with 2 standard outputs, supply out of AS-i, LED display,
potted, with pin connection
BW2527 Emergency stop button with plug-in-shoe connection
BW2530 USB connector cable for Safety Basic Monitor
BWU2532 AS-i Analog Module 4Pt100 Inputsfor 4 wire sensors, 24 V external on M12, IP65
BW2538 Speed Monitor head unit and Speed Monitor for 2 axis
BWU2544 AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 1 AS-i Master, PROFIBUS
slave, Ethernet diagnostics interface
BWU2545 AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 2 AS-i Master, PROFIBUS
slave, Ethernet diagnostics interface
Price/Piece
EUR 790.00
EUR
EUR 290.00
EUR 139.00
EUR
EUR
EUR
98.00
EUR
EUR 1290.00
EUR
69.50
EUR
EUR
490.00
EUR
EUR
98.00
EUR
EUR
EUR
EUR
EUR
39.00
49.00
159.00
EUR
790.00
EUR
EUR
EUR
EUR
49.00
EUR
EUR
EUR
EUR
250.00
850.50
EUR
EUR
EUR
EUR
EUR
19.00
EUR
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
AS-i Master/Gateways/
Links/Scanner
Price List by Article Numbers
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 324
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Price · Payment · General Conditions for the Supply of Products and Services
Price Lists
AS-i Safety
Other Fieldbuses/
Master Simulators
This price list is valid from 28.3.2011 and replaces all previous price lists. This price list is valid until the next
price list will be published.
Net. prices above do not include VAT, packaging or transportation. All orders to be paid within ten days, from
the invoice date.
For all products and services the latest version of the "General Conditions for the Supply of Products and
Services of the Electrical and Electronics Industry (ZVEI)" as well as the added "Retention of Title" are
exclusively in force.
AS-i Accessories/
AS-i Slaves
Diagnostics/Development
Art. No. Article
Price/Piece
BWU2546 AS-i 3.0 PROFIBUS DP Gateway in Stainless Steel, 1 AS-i Master, PROFIBUS
EUR
slave, Ethernet diagnostics interface, 1 gateway + 1 AS-i power supply for 2 AS-i
networks
BW2557 Safety Basic Monitor, 8 release circuits, 8 / 4 safe inputs and 2 (4) electronical safe EUR
outputs, USB interface
AS-i-Master/Gateways/
Links/Scanner
Price List by Article Numbers
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 325
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 326
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
www.bihl-wiedemann.de
We reserve the right to change any data
Mannheim, 29.3.11
page 327
Note
Bihl+Wiedemann GmbH · Floßwörthstr. 41 · D-68199 Mannheim · Phone: (+49) 621/33996-0 · Fax: (+49) 621/3392239 · eMail: mail@bihl-wiedemann.de
page 328
Mannheim, 29.3.11
We reserve the right to change any data
www.bihl-wiedemann.de
Representacte para el mercado Cubano, Fondon Redes y Fluidos, S.L.
email: fondon@fondon.org Skype: FRF-comercial_esp
tel.: +34 985310351 fax: +34 985312309
Avenida Veriña, 5 33211 Gijón Asturias (España)
esentación en Cuba
email: fondon@fondon.co.cu
tel.: (537) 2042384 2042627
C/ 44 nº309 e /3ra y 5ta Miramar
www.fondonglobal.com
La Habana
Cuba
email: fondonmoa@fondon.co.cu
tel.: (5324) 606909 606908
Almacenes Universales C/1ra, s/n, Reparto
Armando Mestre Moa Holguín Cuba