Weighing Scale
4key & 5key
User manual
© EXCELL PRECISION CO., LTD. 2014. All rights reserved worldwide.
The information contained herein is the property of EXCELL PRECISION CO., LTD. and is
supplied without liability for errors or omissions. No part may be reproduced or used except
as authorized by contract or other written permission. The copyright and the foregoing
restriction on reproduction and use extend to all media in which the information may be
embodied.
EXCELL PRECISION CO., LTD.
Table of Contents
INSTRUCTIONS FOR USE .................................................................................................2
PREPARING TO USE THE SCALE ....................................................................................2
CHAPTER 1 INTRODUCTION ............................................................................................4
1-1 PRODUCTION INTRODUCTION .........................................................................................4
1-2 DISPLAY DESCRIPTION ..................................................................................................4
1-3 KEYPAD FUNCTIONS DESCRIPTION .................................................................................5
1-4 POWER DESCRIPTION ...................................................................................................5
1-5 ERROR MESSAGES .......................................................................................................6
CHAPTER 2 GENERAL OPERATION DESCRIPTION .......................................................7
2-1 UNITS SELECTION (ONLY FOR THE MODEL “5KEY”) ...........................................................7
2-2 ZERO FUNCTION ..........................................................................................................7
2-3 TARE FUNCTION ..........................................................................................................7
2-4 NET/GROSS FUNCTION ................................................................................................7
2-5 BACKLIGHT FUNCTION ...................................................................................................8
CHAPTER 3 GENERAL FUNCTION SETTING...................................................................9
3-1
⇒ CHECK WEIGHING CONFIGURATIONS .............................................................10
3-2
⇒ RS-232 INTERFACE OUTPUT SETTING (OPTION) .............................................11
3-3
⇒ EXIT SETTING MODE.....................................................................................17
3-4
⇒ INTERNAL VALUE DISPLAY MODE ...................................................................17
3-5
⇒ G VALUE CALIBRATION ..............................................................................18
3-6
⇒ ID CODE SETTING .....................................................................................19
3-7
⇒ PRINT KEY (
3-8
⇒ PRINTING ORDERS WHEN
) FUNCTION SETTING ........................................................20
IS SET AS ..................................................21
APPENDIX 1 7-SEGMENT DISPLAY CHARACTERS ......................................................23
02018058
1
ZSME300000240
EXCELL PRECISION CO., LTD.
Thank for your purchasing of our EXCELL Weighing
Scale. To guide you to use our product correctly, please
read this User Manual carefully to extend the life of
machine and to avoid error.
Instructions for Use
1. Please keep scale in a cool and dry place. Do not store under high temperatures.
2. Please keep the scale clean and free from insect infestation.
3. Avoid impacting with other items or overloaded with excessively heavy weights (The
load must not exceed the maximum capacity of the scale).
4. If the scale is not going to be used for some time, please clean it and store it in a plastic
bag in dry condition. A desiccant sachet may be included to prevent moisture from
building up.
5. Do not mix different types of dry battery or mix used dry batteries with new dry batteries.
6. Please operate or charge the scale in an open area. Do not squeeze the power cord to
avoid wire on fire.
7. Operating temperature: -10℃ ~ + 40℃
8. Any suggestion is warmly welcome.
Preparing to Use the Scale
1. Locate the scale on a firm level surface free from vibrations for accurate weight readings.
Adjust the four leveling feet to centre the leveling bubble on the scale.
2. Avoid hot sunshine directly on the scale or near the exhaust port of ventilating system.
3. Please use a separate power source plug, to avoid the disturbance of other electric
appliance.
4. There should be no weight on the scale when power is turned on.
5. Commodity should be placed at the centre of platter when being weighed, and its size
should not exceed the dimension of the platter.
6. Please warm the scale 15 ~ 20 minutes before using.
7. Please note that when
charged.
symbol appears on the screen, the scale needs to be
8. Introduction of Storage Battery:
02018058
2
ZSME300000240
EXCELL PRECISION CO., LTD.
Due to the storage battery adopt the advanced free-maintaining technique, customers need
not to replenish electrolyte.
The scale should be recharged every 3 months to prevent failure of the internal
rechargeable battery.
1. The battery should be charged for 8~10 hours.
2. The temperature of battery should below 45℃.
Maintaining
1. Please do not discharge with over-current when using the battery. Please charge the
battery after discharging current.
2. Please take down the battery when the scale is not used for a long time or break the
connection of cathode.
3. Do not short the battery terminals to check whether there is current. Please check
whether the connection point is firm to guarantee good connection.
4. The battery should be replaced by specialized person. No reverse-battery or the
product will be damaged.
a) Anode of battery should be connected with Anode of product battery(usually red
cable)
b) Cathode of battery should be connected with Cathode of product battery (usually
brown cable or black cable)
c) See the picture following
Brown cable(or black cable)
connected with Anode of
battery
Red cable connected with
Cathode of battery
Safety warnings
1. The electrolyte of battery is caustic which causes metal, cotton, etc to corrode.
2. The hydrogen will be resolved when using or charging the battery and it will cause
explosion when approaches fire.
02018058
3
ZSME300000240
EXCELL PRECISION CO., LTD.
Chapter 1 Introduction
1-1 Production Introduction
1. High performance A/D converter
• 0.3 uv/D high sensitivity
• zero point adjustable range -2mV~ +5mV
• Sampling speed 15 times/second • use range -4mV ~ +30mV
• non-linear scale 0.01% full scale
• load cell stimulate power source 5V DC ±2% 100mA
2. According to different resolution to do linearity calibration
¾ Ordinary resolution models (below 10000)
Do specification calibration first then do weight calibration
¾ High resolution models (10000~30000)
Do linearity calibration first→ specification calibration → weight calibration at last
3. One group of RS232 (option)
4.4 HOLD functions (contain animal scale HOLD function)
5. LCD display
6. Adapter and rechargeable battery
7. Blackout automatically in order to keep the system stable
(When battery voltage is lower than system voltage, the system will cut the power off
automatically to ensure its stable and accuracy.)
8. LED BACKLIGHT
1-2 Display Description
HI
OK
LO
→O← Net
kg
lb
斤
Pcs
%
02018058
:
:
:
:
:
:
:
:
:
:
High limit value
OK value
Low limit value
“Zero” indication
“Net weight” indication
“kg” unit
“lb” unit
No function
Counting mode
Percent indication
▼1
▼2
▼3
▼4
▼5
▼6
▼7
4
:
:
:
:
:
:
:
:
“Low battery power” indication
“Stable” indication
“Pre-tare mode” indication
“Accumulation mode” indication
No function
“Samples insufficient” indication
“Unit weight insufficient” indication
“Viss” unit (Burma unit)
ZSME300000240
EXCELL PRECISION CO., LTD.
1-3 Keypad Functions Description
4-key model has no
key.
Press this key to zero the scale.
Press this key to tare (deduct the container weight)
Net/Gross key
Press this key to print
Press this key to select the required unit from the preset units
1-4 Power Description
Power Selection
1. 6 V / 4 Ah Rechargeable battery
2. 110 V / 220 V ±15 % AC
Recharge Voltage
1. AC 110 V
+10% , -15%
2. AC 220 V
+10% , -15%
Power Consumption
State
(indicator+ L/C + no backlight)
indicator+ L/C + front display
backlight
indicator+ L/C + front display
backlight +back display backlight
Single RS-232
02018058
Consumption
26 mA
Time
180 hours
32 mA
140 hours
40 mA
110 hours
20 mA
5
ZSME300000240
EXCELL PRECISION CO., LTD.
Low Power Alarm
Please note when the (
) symbol keeps flashing on the left down corner of the
display, the batteries should be recharged.
The scale will turn off automatically after a few hours when the low battery warning symbol
shows up. The scale must be fully recharged, before operating again.
Please recharge at once when the symbol
shows in order to keep the weight
accuracy.
1-5 Error Messages
⇒ Weight exceed 9d of maximum capacity. (d=division)
⇒ Zero value after power on is over +10% FS.
⇒ Zero value after power on is less than -10% FS.
⇒ Unstable zero return, unstable over 10 sec. Press
to leave E4.
⇒ Zero is too high when calibrating. (over internal value350,000)
⇒ Zero is too low when calibrating. (under internal value 80,000)
----- ⇒If there is no Tare or Pre-tare, the weight is less than -20d.
02018058
6
ZSME300000240
EXCELL PRECISION CO., LTD.
Chapter 2 General Operation Description
2-1 Units Selection (
) (only for the model “5key”)
Press
key to select the units “kg” and “lb”.
The selected unit will be memorized when you turn the scale off. And the memorized
unit will appear after you turn on the scale next time.
2-2 Zero Function (
)
Press
key to re-zero the display with no load on the platter. When zero is set, the
“ Æ0Å ” symbol will be displayed.
2-3 Tare Function (
♦
♦
♦
)
Place the container on the platter, after stable and press
key, the weight value
returns to zero and net indication “ 6 ” is on.
Place goods into the container, then the scale shows the net weight of goods.
When removing the container and goods, the display shows the negative weight value
of the container. Then press
key to clear tare value. The scale returns to zero
and Net indication “ 6 ” is on.
Continuous tare rang =Full Scale.
Multiple tare operation ⇒ Users can continuously increase or decrease the tare
value by pressing the
key.
2-4 Net/Gross Function (
In Tare mode, press
)
key once to display gross value. Net symbol “▼”disappears,
and the gross value “▼” appears. Press
key again, it displays net value, net
symbol “▼” appears and gross symbol “▼” disappears. Press
to display net value or gross value. In tare mode,
displays “▼”, all keys are disable except
02018058
7
key continually
key is able to work. When it
.
ZSME300000240
EXCELL PRECISION CO., LTD.
2-5 Backlight Function
<Method 1>
Press
key, the display shows “CEntr”. At this time, press
key to select
backlight mode. There are auto backlight mode(The display shows “BL.Auto” ),
backlight on mode( The display shows “BL.
on” ) and backlight off mode ( The display
shows “BL. oFF” ).
<Method 2>
Press the hide key in order to select auto backlight mode, backlight on mode and
backlight off mode.
• Auto backlight mode ( BL.Auto ) : When the weight is over 10d or any key is
pressed, the display backlight will be switched on. When the weight is less than 10d,
the display backlight will be switched off after 8 seconds.
•
Backlight on mode ( BL.
02018058
on ) : Display backlight is on all the time.
8
ZSME300000240
EXCELL PRECISION CO., LTD.
Chapter 3 General Function Setting
♦ Switch on the scale. While the scale is counting down to zero, press and hold
key
until the display shows the software program version number
Release the
key, the scale enters into the configuration setting mode and
is showed on the display.
⇒ Reserved
Press
key
Press
key
Press
key
Press
key
⇒ Reserved
⇒ Reserved
Press
key
⇒ Reserved
⇒ Check-weighing configurations
Press
key
⇒ RS-232 Interface output Setting
⇒ Exit setting mode
Press
key
Press
key
⇒ Internal value display mode
⇒ Reserved
Press
key
Press
key
⇒ Reserved
⇒ G Value adjustment
Press
key
Press
key
⇒ ID code setting
⇒ Print key (
) function setting
⇒ Reserved
Press
key
Press
⇒ Printing orders when
key
is set as
or
⇒ Reserved
02018058
9
ZSME300000240
EXCELL PRECISION CO., LTD.
⇒ Check Weighing Configurations
3-1
♦
If hold mode is set, accessing to
Use
or
is denied.
key to select F4 function ⇒ the display shows
kg
.
Press
key
.
kg
Press
key for 5
times to clear HI, OK,
LO values
Press
key
Preset “LO value”
(LO value > 10d)
and
Press
key to set “ LO value”
E.g. LO value = 2 kg
.
Press
kg
key = Increase the flash value by one (0 ~ 9)
key
key = Confirm key
.
kg
Preset “HI value”
(HI value ≥ LO value)
Χ Χ
A B
A ⇒ 0 = After stable, the beeper beeps and the
Press
and
E.g. HI value =2.5kg
indications are on
key to set “ HI value”
1 = After stable, the beeper beeps; whether
kg
stable or not, the indications are on
.
2 = whether stable or not, the beeper beeps
and the indications are on.
Press
key
3= open warning device: when the weight is
kg
higher than HI value and the weight is stable,
LCD is on and Relay Card open.
Preset “Beeper value”
B ⇒ 0 = No beep
1 = OK (when the weight is between Low limit &
Press
and
High limit.), the beeper beeps.
key to set “Beeper value”
E.g.Beeper value=22
2 = When the weight is under or equal to Low
limit (must be over 10d) & over or equal to
kg
High limit, the beeper beeps.
♦ LCD indication description:
Press
02018058
key
Ñ
Ò Ñ
Ò Ñ
Ò
⏐ÕÕÕ⏐ÕÕÕÕ ÖÖÖÖ⏐ÖÖÖ
10d Low limit value High limit value
10
ZSME300000240
EXCELL PRECISION CO., LTD.
⇒ RS-232 Interface Output Setting (option)
3-2
Use
or
key to select F5 function ⇒ the display shows
Press
key
The display shows the default
setting of transmission mode
key = Increase the flash value by one (from 0 to 10) or
selecting baud rate from 1 200, 2 400,4 800 and
9 600(default setting)
key =Confirm key
Press
key
Select transmission mode
(from 0 ~ 10 )
⇒ No transmission
⇒ Stable transmission *
⇒ Continuous transmission *
Press
key
The display shows the default
setting of RS-232 baud rate
⇒ Press
key to transmit in simple mode. *
⇒ Press
key to transmit in complete mode. *
⇒ Stable transmission in totalizing mode.
*
The format is as same as
Press
key
Select RS-232 baud rate
(1 200, 2 400, 4 800,9 600)
⇒ Refer to F14 *
⇒ Refer to F14 *
⇒ Press
Press
key to transmit *
The format is as same as
key
and
*
⇒ Continuous transmission,specific format *
⇒
transmit specific format *
* : RS-232 is open
For Brazil models, if unit weight is less than 0.1d, RS232 closed.
02018058
11
ZSME300000240
EXCELL PRECISION CO., LTD.
RS-232 Interface Format
I . Mode: UART Signal of EIA-RS0232 C
II . Format :
1. Baud rate
: 1 200, 2 400, 4 800, 9 600 bits/second
2. Data bits
: 8 bits
3. Parity bit
: None
4. Stop bits
: 1 bit
5. Code
: ASCII (Exchange code of American standard)
Start bit
Data bits
RS-232 Data Format
Stable transmission (
Press
), Continuous transmission (
key to transmit (
(1) gram as weight unit
1 2 3 4 5 6 7
HEAD
1
,
,
8
,
HEAD
,
±
,
HEAD
,
02018058
HEAD
, ±
CR LF
10 11 12 13 14 15 16 17 18 kg/l
b
DATA
(4) HK tael as weight unit
1 2 3 4 5 6 7 8
HEAD
9
UNIT
g
UNIT
CR LF
9 10 11 12 13 14 15 16 17 18 19 20 21 Lb.oz
,±
HEAD , HEAD
,±
(5) viss as weight unit
1 2 3 4 5 6 7
10 11 12 13 14 15 16 17
DATA
(3) lb.oz as weight unit
2 3 4 5 6 7 8
HEAD
9
DATA
8
),
)
±
(2) kg or lb as weight unit
2 3 4 5 6 7
HEAD
1
HEAD
Stop bit
CR LF
9 10 11 12 13 14 15 16 17 18 19 20
DATA
8
UNIT
UNIT
CR LF
9 10 11 12 13 14 15 16 17 18 19 20
DATA
12
UNIT
HK
tael
viss
CR LF
ZSME300000240
EXCELL PRECISION CO., LTD.
HEAD1 ( 2 BYTES )
OL - Overload , Under load
ST Display is Stable
US Display is Unstable
HEAD2 ( 2 BYTES )
TR TARE Mode
NT NET Mode
GS GROSS Mode
DATA ( 7 or 8 BYTE )
2B ( HEX ) = “ + ” ( PLUS)
2D ( HEX ) = “ – ” ( MINUS )
2E ( HEX ) = “ . ” ( DECIMAL POINT )
UNIT ( 2、3 or 4 BYTE )
kg
= 6B ( HEX ) ;
lb
= 6C( HEX ) ;
tl.T = 74 ( HEX ) ;
hkg = 68 ( HEX ) ;
viss = 76 ( HEX ) ;
67 ( HEX )
62 ( HEX )
6C ( HEX )
67 ( HEX )
69 ( HEX )
;
2E ( HEX )
;
54 ( HEX )
;
73 ( HEX )
;
73 ( HEX )
Transmission examples:
Data format for
RS-232 continuous transmission are as below:
1. The gross weight (+0.876 kg) shows as below, after stable: (under tare mode)
S T
, G S
,
+
0
.
8 7 6
k
g 0D 0A
HEAD1
, HEAD2
,
DATA
UNIT
C
LF
2. The net weight (-1.568 lb) shows as below without weight stability: (under no tare mode)
U S
,
N T
,
1
.
5 6 8
l
b 0D 0A
HEAD1
,
HEAD2 ,
DATA
UNIT
C
LF
3. The net weight (+15.0624 HK tael) shows as below, after stable: (under no tare mode)
S T , N T , + 1 5 . 0 6 . 2 4 h k g 0D 0A
HEAD1
, HEAD2
,
DATA
UNIT
C
LF
4. The net weight (+1.245 viss) shows as below, after stable: (under tare mode)
S T , T R , +
1 . 2 4 5 v i s s 0D 0A
HEAD1
02018058
,
HEAD2
,
DATA
13
UNIT
C
LF
ZSME300000240
EXCELL PRECISION CO., LTD.
Press
key to transmit (simple mode)
S/N
WT/UNIT ( kg / lb )
-------------0001
1.0000
( Press
0002
1.0000
( Press
0003
1.0000
( Press
0004
1.0000
( Press
0005
1.0000
( Press
-------------0005
Press
5.0000
( Press
twice to print TOTAL
key to transmit (complete mode)
4 key serial
TICKET
NO .0001
G
1.000kg
T
0.000kg
N
1.000kg
(3 blank lines)
TICKET
NO .0002
G
1.000kg
T
0.000kg
N
1.000kg
(3 blank lines)
TICKET
NO .0003
G
1.000kg
T
0.000kg
N
1.000kg
(3 blank lines)
TOTAL NUMBER
OF TICKETS 0003
TOTAL
NET
3.000kg
(3 blank lines)
02018058
( Press
( Press
( Press
( Press
14
twice to print TOTAL
ZSME300000240
EXCELL PRECISION CO., LTD.
Stable Transmission (totalizing mode)
S/N
WT/UNIT ( kg / lb )
-------------0001
1.0000
( The scale is stable
0002
1.0000
( The scale is stable
0003
1.0000
( The scale is stable
0004
1.0000
( The scale is stable
0005
1.0000
( The scale is stable
-------------0005
5.0000
twice to print TOTAL
( Press
RS232 output format in HOLD MODE
Please set
in
.
1. If there is only RS232, press
MODE.
key to print out the HOLD value on display in HOLD
Continuous Transmission (specific form)
The print out is as below:
If display shows 70.15kg, the number RS-232 export is 51.07000
If display shows -70.15kg, the number RS-232 export is 51.0700If it is ol, then it won’t do anything.
key Transmission (specific form)
F
R
“
? <LF>
G
G
,
T
T
,
PT PT
,
N
N
,
pcs pcs pcs
n
n
n
p
1
,
W
T
3
G
G
G
T
T
T
PT PT PT
N
N
N
pcs pcs pcs
n
n
n
1 <LF>
N
“ <LF>
<LF>
<LF>
<LF>
<LF>
<LF>
t
t
t
t
t
t pcs pcs pcs pcs pcs pcs <LF>
For example:
PT 0.3KG
T 0.7KG
G 1.2KG
N 0.2KG
PCS
20
02018058
15
ZSME300000240
EXCELL PRECISION CO., LTD.
Then the printing form is:
FR”WT3N ”
?
1,200
0,700
0,300
0,200
20
000020001000000020
P1,1
Use
key twice to clear the format
Then, form of clearing the printing
F
R
“
5
? <LF>
TN TN TN TN TN
TW TW TW TW TW
TA TA TA TA TA
tn
tn
tn tn
tn
tn
tn
tn tn
tn
p
1
,
1 <LF>
“ <LF>
TN
TW
TA
tn
tn
<LF>
<LF>
<LF>
<LF>
tw tw
tw
tw tw tw ta
ta
ta
ta
ta
ta <LF>
FR”520T ”
?
1
0,200
20
000001000200000020
P1,1
02018058
16
ZSME300000240
EXCELL PRECISION CO., LTD.
⇒ Exit Setting Mode
3-3
Use
key to select F6 function ⇒ the display shows
or
Press
key
Counting down to zero
and exit setting mode
⇒ Internal Value Display Mode
3-4
Use
or
Press
key to select F7 function ⇒ the display shows
key
Internal value
Press
02018058
key
17
ZSME300000240
EXCELL PRECISION CO., LTD.
⇒ G value Calibration
3-5
Use
key or
key to select F10 function. ⇒ The display shows
.
You can input at most 9 sets of G value’s data. The historic data can be found out and
not to be revised.
After about 1 second
.
Press
key
Press
The screen displays revised times at present and then displays local G value after about 1 second.
key
After about 1 second
Press
key
.
The screen displays last revised times and then displays local G value after about 1 second.
Press
key
After about 1 second
.
Press
key
Press
The screen displays the first two revised times and then displays local G value after about 1 second.
key
After about 1 second
.
Press
key
Press
key
“01” ⇒ Fix to save ADJ condition, input local G value in F9.
After about 1 second
.
Press
key to
enter into G value
revised mode.
“00” ⇒ Fix to save G value in manufacture site.
.
Use
Input local G value
and
key to input the
key to Shift the flashing
number. Press
digit one space to right.
.
Press
key to save
the data and then complete
the revise.
02018058
18
ZSME300000240
EXCELL PRECISION CO., LTD.
⇒ ID Code Setting
3-6
,
(Use must be in coordination with
Use
)
key to select F11 function ⇒ the display shows
key or
Press
,
key
Machine ID code setting:
Press
and
to set 01 ~ 99
Default setting: 00
(1) “00”: RS-232 does not transmit Machine ID
(2) “01~99”: RS-232 transmits Machine ID
Press
key
RS232 DATA FORMAT
Stable transmission (
Press
), Continuous transmission (
key to transmit (
),
)
1. e.g. Machine ID code is 10.
The gross weight (+0.876 kg) shows as below, after stable: (no tare or under pre-tare
mode)
1
0
ID
S
T
,
HEAD1
,
G
S
HEAD2
,
+
0
0
,
0
.
8
7
6
DATA
k
g
UNIT
0D 0A
C
LF
2. e.g. Machine ID code is 00. (Not using Machine ID function.)
The net weight (-1.568 lb) shows as below without weight stability: (under tare or pre-tare mode)
U
S
HEAD1
02018058
,
N
,
T
HEAD2,
,
-
0
0
1
.
DATA
19
5
6
8
l
b
UNIT
0D 0A
C
LF
ZSME300000240
EXCELL PRECISION CO., LTD.
3-7
Use
⇒ Print Key (
key or
Press
) Function Setting
key to select F12 function ⇒ the display shows
key
Use
and
to set 0 ~ 2
Default setting: 0
Press
key
⇒ Press
key to print current weight if weight variation is within ±1d
~ ±10d, or to print accumulated weight if weight variation is over ±10d.
(d=division)
⇒ Press
key to print the current weight at once. (no totalization)
⇒ Press
key to print the current weight if it is within the lower and
upper limits. (no totalization)
02018058
20
ZSME300000240
EXCELL PRECISION CO., LTD.
⇒ Printing orders when
or
3-8
No.0
No.1
No.2
No.3
No.4
No.5
No.6
No.7
No.8
No.9
is set as
No print.
TICKET NO.
G
T
PT
N
P/N
S/N
No print
No print
Contains a 9-digit code
If
is set as
n The format of
is as following
S/N
WT/UNIT (kg / lb)
-------------0001
1.0000
( Press
key
0002
1.0000
( Press
key
0003
1.0000
( Press
key
0004
1.0000
( Press
key
0005
1.0000
--------------
( Press
key
0005
( Press
key twice to print the total
5.0000
o The format of
02018058
: RS-232 print nothing
21
ZSME300000240
EXCELL PRECISION CO., LTD.
If
is set as
nThe format of
is as following
P/N 012345678901
TICKET NO. 0001
G
75.01kg
T
0.00kg
PT
0.00kg
N
75.01kg
S/N
WT/UNIT ( kg / lb )
-------------0001
1.0000
( Press
key
0002
1.0000
( Press
key
0003
1.0000
( Press
key
0004
1.0000
( Press
key
0005
1.0000
--------------
( Press
key
0005
( Press
key twice to print the total.
5.0000
o The format of
P/N 012345678901
TICKET NO. 0001
G
75.01kg
T
0.00kg
PT
0.00kg
N
75.01kg
TOTAL NUMBER
OF TICKETS 0001
TOTAL
NET
0.499kg
02018058
is as following
( Press
key
( Press
key twice to print the total
22
ZSME300000240
EXCELL PRECISION CO., LTD.
Appendix 1 7-Segment Display Characters
Number
Display
Letter
Display
Letter
0
A
N
1
B
O
2
C
P
3
D
Q
4
E
R
5
F
S
6
G
T
7
H
U
8
I
V
9
J
W
K
X
L
Y
M
Z
℃
02018058
23
Display
ZSME300000240