HI 9829
Portable GPS Multiparameter Meter
w w w.hannains t.com
an ISO 9001:2000 Cer tified Company
Features
• Field replaceable ISO 7027 compliant
turbidity sensor
• Ammonium, chloride and nitrate ISE’s
• Logging from probe or meter
• Fully customizable instrument, probe,
sensors and measurement
specifications
• Display from one to twelve parameters
with font dimension adjustment
• Field replaceable sensors
• pH/ORP or pH, four ring EC or EC/
Turbidity and galvanic DO sensors
HI 9829
• Auto-recognition of all sensors
Portable GPS
Multiparameter
Meter
• Rugged probe with stainless steel tip
has a diameter under 2” for wells
and pipes
• Track measurement locations with GPS
(HI 98290)
• Fast Tracker™—Tag I.D. System
simplifies periodic monitoring
• Features a built-in barometer for DO
concentration compensation
• Quick or independent sensor
calibration feature
• Measurement check eliminates
erroneous readings
• Logged data can be displayed as graphs
• Graphic LCD with backlight
• USB for PC connectivity
• Good Laboratory Practice feature
with last five parameter calibrations
recorded
• Meter accepts both alkaline and
rechargeable batteries
• Waterproof protection for meter (IP67)
and probes (IP 68)
The Perfect Monitoring Tool
Rugged, waterproof and easy to use, the HI 9829 and HI 98290 are
the ideal meters for field measurements of lakes, rivers and seas. Both
meters display one to twelve parameters simultaneously from up to
fifteen user selectable parameters.
The HI 98290 with the GPS option incorporates a built-in GPS receiver
and antenna that guarantees position accuracy. Measurements from
specific locations are tracked with detailed coordinate information that
can be viewed immediately on the display.
Combined with one of the HI 76x9829 series probes, the HI 9829
and HI 98290 can measure water quality parameters such as pH,
ORP, conductivity, turbidity, temperature, ions ammonium, nitrate,
chloride (as NH4+—N, NO3-—N or Cl-), dissolved oxygen (as % saturation or
concentration), resistivity, TDS, salinity, and seawater σ. Atmospheric
pressure is measured for DO concentration compensation.
Both meters feature a graphic, backlit LCD that scales digits to fit up
to twelve parameters and allows full configuration of each parameter
measured along with an on-screen graphing capability.
HELP key displays context sensitive help. The alphanumeric keypad
offers a user friendly way to complete the input fields.
Water scientists and managers alike utilize data-collection programs
as part of environmental monitoring. These programs are designed
to reveal changes in water and the environment around it over time.
Reliable, dependable measurements are required to monitor these
changes and understand the contributions from seasonal fluctuations,
weathering, as well as manmade pollution.
pH, ORP, ISE, EC, TDS, Resistivity,
Salinity, Seawater σ, Turbidity, DO,
Temperature and Atmospheric Pressure
Intuitive
Sensors
offers a selection of eight sensors to be used
Configuration, Hanna
on the intelligent probes. Sensor replacement is
Measurement quick and easy with screw type connectors and color
coded sensors. The HI 9829 & HI 98290 automatically
and Help
recognize sensor presence.
• Help
The context sensitive help
screen is always accessible.
• Fully Configurable
Measurement Screen
• Calibration
Calibration with the HI 9829(0) is
easy and intuitive.
• Graphing
Trend graphing may be viewed
on the display or transferred
to a PC. The sample date and
time stamp will also be displayed.
The new HI 7609829-4 EC/turbidity sensor is field
replaceable and offers readings from both parameters
at the same time.
All potentiometric sensors feature a double junction
design and are gel filled to increase resistance to
contamination. An ISE sensor can be used in place of
the pH sensor and is automatically recognized. pH in mV
readings are also displayed —ideal for troubleshooting.
• Quick Calibration
Simply screw the calibration
beaker filled with HI 9828-25
solution onto the probe, select
“Quick calibration” from the menu
and press OK. Individual calibration
may also be performed using
multiple calibration points.
• Auto-sensor recognition
In this example, the HI 9829 is
identifying a pH, dissolved
oxygen and turbidity/EC sensor.
Sensor Configurations
Both probes can accommodate a multitude of sensor configurations.
The long sensor cap fits all configurations while the short sensor cap fits
configurations not requiring the turbidity/EC sensor.
or
Dissolved
Oxygen
HI 7609829-2
DO
or
pH
ISE
Conductivity
HI 7609829-0
pH
HI 7609829-10
Ammonium ISE
HI 7609829-3
EC
HI 7609829-1
pH/ORP
HI 7609829-11
Chloride ISE
Conductivity &
Turbidity
HI 7609829-4
EC/Turbidity
HI 7609829-12
Nitrate ISE
Short cap
Long cap
HI 7698295
Short cap for probes
without EC/Turbidity
HI 7698296
Long cap for probes
with EC/Turbidity
A Great Combination
The use of Hanna’s microprocessor based multiparameter intelligent
probes with HI 9829 and HI 98290 meters will provide reliable data
collection. These meters can aid in an improved scientific understanding
of the interconnections between natural, chemical and geological
processes and man made pollution to effectively evaluate applications
for waste-discharge permits, remediate contaminated sites and to
protect or restore biological resources.
The HI 76x9829 probes utilize field replaceable sensors with autorecognition. The sensors are housed with the probe electronics in a
rugged housing with a water-tight cable connection. The HI 76909829
probe allows conductivity, pH/ORP (or an ISE), and dissolved oxygen
measurement. Other probe models allow turbidity and logging. The
probes are available with a choice of cable lengths such as 4 m and 10
m and 20 m (13, 33’) that utilize a DIN connection to interface with the
meters. Logging probes can be connected directly to a PC with the
HI 76982910 USB adapter cable, and HI 929829 PC application software
to download log files directly from the probes.
Reliable temperature measurements are a critical parameter of aquatic
system monitoring. Temperature and temperature changes due to
water releases can affect the ability of water to hold oxygen, as well
as the ability of organisms to resist certain pollutants. The intelligent
probes incorporate an accurate thermistor that changes predictably with
temperature changes. Accurate temperature reading in degrees Celsius,
Kelvin or Fahrenheit are displayed and utilized by other detectors for
temperature correction.
The pH and pH/ORP sensors feature a double junction design and
are gel filled to increase resistance to contamination. These sensors
incorporate the technology that has made Hanna so successful as a pH
manufacturer. Reliable pH measurements are one of the most important
indicators of water chemistry indicating the relative amount of free
hydrogen and hydroxyl ions in the water. Hanna’s pH sensors utilize a
resilient PEI body to protect them from solid particulates found water
samples. Consistency and quality are the hallmarks of these sensors. Our
differential measurement system further enhances the measurement
reliability providing temperature corrected pH.
A choice of three ion selective electrodes is available for constant
reporting of common surface water contaminants. Nitrate,ammonium
and chloride ISE’s are available. Each ISE is a combination electrode
incorporating an extremely constant reference spiral; all
potentionmetric probes feature a double junction and solid gelled
Autonomously Logging Probes
After starting a log, the HI 7629829 and HI 7639829 logging probes can
autonomously log parameters without further connection to the HI 9829
or HI 98290. Just connect the logging probe to the HI 9829, HI 98290 or a
PC to retrieve the logged measurements.
General Probe Specifications
Temperature Sensor
built-in
Operating Temp.
-5 to 55ºC*
Sample Environment
fresh, brackish, seawater
Waterproof Protection
IP68
Cable Specification
Multistrand-multiconductor shielded cable with internal strength member rated for 68 kg (150 lb.) intermittent use
Wetted Materials
Body: ABS; Threads: nylon; Shield: ABS/316 SS; Temperature Probe: 316 SS; O-rings: EPDM
HI 7609829
Supported
Configuration
Connector 1
Supported
Configuration
HI 7619829
dissolved oxygen
Connector 3
Dimensions / Weight
EC
EC/Turbidity
to HI 7619829, adding EC/turbidity sensor and long protective shield
—
342 mm (13.5”), dia=46 mm (1.8”) / 570 g (20.1 oz.)
382 mm (15.1”), dia 46 mm (1.8”) / 650 g (22.9 oz.)
HI 7629829
HI 7639829
Connector 1
pH, pH/ORP, ammonium ISE, chloride ISE, nitrate ISE
Connector 2
dissolved oxygen
Connector 3
Upgradable
20 m (66’)*
pH, pH/ORP, ammonium ISE, chloride ISE, nitrate ISE
Connector 2
Upgradable
Maximum Depth
EC
EC/Turbidity
to HI 7639829, adding EC/turbidity sensor and long protective shield
Autonomous Logging
—
yes
Logging Interval
1 second to 3 hours
Computer Interface
USB (HI 76982910)
Memory
140,000 measurements (single parameter logged); 35,000 measurements (all parameters logged)
Logging Probe Internal Battery Type
Logging Probe Battery Life**
Dimensions / Weight
1.5V (4) AA alkaline
Interval : 1 - 5 seconds, 1 minute, 10 minutes; All channels logging (no averaging): 72 hours, 22 days, 70 days;
All channelslogging (10 sample averaging): 72 hours, 11 days, 65 days
442 mm (17.4”), dia 46 mm (1.8”) / 775 g (27.3 oz.)
482 mm (19.0”), dia 46 mm (1.8”) / 819 g (28.9 oz)
HI 7609829
HI 76198298
HI 7629829
HI 7639829
pH/ORP, DO, EC
pH/ORP, DO,
EC/Turbidity
pH/ORP, DO,
EC, Logging
pH/ORP, DO, EC/
Turbidity,
Logging
reference design. By utilizing conductivity, the HI 9829 and HI 98290 can
convert ion activity measurements to concentration units. The HI 9829(0)
displays these measurements as ppm ammonium-nitrogen, ppm chloride
and ppm nitrate-nitrogen.
probes built-in temperature sensor) and atmospheric pressure (using the
HI 9829 and HI 98290’s internal atmospheric pressure sensor). The DO
measurement complies with standard methods 4500-0 G. and EPA
article 360.1.
The HI 7609829-3 four-ring conductivity sensor using the
potentiometric measurement principal ensures stable conductivity
readings. Electrolytic conductivity measures of the ability of water
to conduct an electrical current. It is highly dependent on the amount
of dissolved solids (such as salt) in the water. Absolute conductivity,
temperature corrected conductivity, salinity, seawater σ and water
hardness (TDS) determinations are possible with measurements from
this sensor.
The HI 7609829-4 combined EC/turbidity sensor is a replaceable
design for instantaneous conductivity and turbidity measurements
that conform to ISO 7027 standards. It provides measurements from
0.0 to 1000 FNU. Turbidity is the amount of particulate matter that
is suspended in water. Turbidity measures the scattering effect that
suspended solids have on light: the higher the intensity of scattered
light, the higher the turbidity. Material that causes water to be turbid
include: clay, silt, finely divided organic and inorganic matter, soluble
colored organic compounds, plankton and microscopic organisms.
Conductivity measurement is the same as in the HI 7609829-3.
The oxygen dissolved in lakes, rivers, and oceans is crucial for the
organisms and creatures living in it. If dissolved oxygen concentrations
drop below normal levels in water bodies, the water quality degrades
and the organisms begin to die off. The HI 7609829-2 galvanic DO sensor
does not require long polarization times so it is ready for measurement
at a moment’s notice. This sensor also utilizes a replaceable membrane
cap design for ease of maintenance and a safe non-toxic electrolyte.
DO readings are compensated for the effects of temperature (using the
* Reduced for ISE sensors, **Log space must be available for continuous logging
Probes with the logging function have a logging memory that allows
storage of up to 140,000 individual samples or 35,000 complete sample
data sets with date and time stamp thus permitting up to a 70 day
deployment with all channels logging at 10 minute intervals. The probe
incorporates a temperature sensor for temperature compensation of
all parameters.
Fast Tracker™
Tag Identification System
Hanna’s Fast Tracker ™—Tag Identification System simplifies test logging. iButton®s with a unique ID can be
installed at various sampling sites. When the matching connector on the meter contacts the location button,
measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date,
time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker ™
system complements the GPS for ultimate tracking.
Install the optional TAGs near your sampling points for
quick and easy iButton® readings. Each TAG contains a
computer chip with a unique identification code encased
in stainless steel. You can install a practically unlimited
amount of TAGs. Additional TAGs can be ordered for all of
your traceability requirements.
Monitoring and Tracking
The HI 98290 with GPS module can track measurement locations with detailed coordinate
information. All models of the HI 9829 are equipped with the Fast Tracker ™ TAG ID system which
is an invaluable tool for associating measurements with their locations. HI 9829(0) meters also
incorporate a real-time clock which stamps all logged data with a time and date in addition to
location information.
The new HI 98290 features an internal 12 channel GPS receiver and antenna that calculates its
position to track locations along with measurement data. The GPS tracks your location using
satellites to within 30 ft (10 m) so you can be sure that you return to the same location for
repeated measurements. The GPS coordinates can be shown on the LCD together with up to 10
measurement parameters and are recorded with logged data. Users can connect to GPS tracking
software such as Google™ Maps* to view locations where samples have been taken. Measurement
information is shown right on the map.
GPS data can be customized to
meet specific requirements.
Displays distances between
current and predefined locations.
Display current readings along
with GPS coordinates
Shows current position and
number of satellites.
• Basic GPS Features
• Advanced GPS Features
• HI 929829 PC Application Software
· GPS coordinates shown on the LCD with up to
ten measurement parameters
· Users can associate GPS coordinates with
alphanumeric locations
· Manages logged data from the HI 9829
· GPS signal strength shown on LCD
· Distances between current location and
predefined locations are displayed arranged
by distance
· Automatically maps samples on your PC
(internet connection required)
· Logged data is embedded with GPS
coordinates
· GPS status screen
· Memorizes last location and time should
signal be lost
*Google™ is a registered trademark of Google™, inc. HANNA Instruments® has no
affiliation with Google™.
· Displays GPS coordinates with logged data
· Shows location points on map with
measurement data
SPECIFICATIONS
Temperature Compensation
HI 9829
HI 98290
automatic from -5 to 55°C (23 to 131°F)
GPS
—
Logging Memory from Meter
12 channel receiver
44,000 records
Logging Interval
1 second to 3 hours
Computer Interface
USB (with HI 929829 software)
FastTracker™ TAG ID
yes
Waterproof Protection
IP67
Environment
0 to 50°C (32 to 122°F); RH 100%
Power Supply
1.5 alkaline C cells (4) / 1.2 V NiMH rechargeable
C cells (4), USB, 12 V power adapter
Dimensions
221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)
Weight
750 g (26.5 oz.)
HI 9829 and HI 98290 PARAMETER SPECIFICATIONS
AmmoniumpH / mV of Input
ORP mV
Nitrogen
NitrateChloride
Nitrogen
Range
0.00 to 14.00 pH / ±600.0 mV
±2000.0 mV
0.02 to 200 ppm
(as N)
Resolution
0.01 pH / 0.1 mV
0.1 mV
0.01 ppm to 1 ppm; 0.1
ppm to 200 ppm
Accuracy
±0.02 pH / ±0.5 mV
±1.0 mV
±5% of reading or 2 ppm, ±5% of reading or 2 ppm, ±5% of reading or 2 ppm,
whichever is greater
whichever is greater
whichever is greater
Conductivity
TDS
0 to 400000 mg/L or ppm
(the maximum value depends
on the TDS factor)
Range
0 to 200 mS/cm
(absolute EC up to 400 mS/cm)
Resolution
manual:
1 mg/L (ppm); 0.001 g/L (ppt);
0.01g/L (ppt); 0.1 g/L (ppt);
1 g/L (ppt);
manual:
autorange scales:
1 µS/cm; 0.001 mS/cm; 0.01 mS/cm;
1 mg/L (ppm) from
0.1 mS/cm; 1 mS/cm;
0 to 9999 mg/L (ppm);
automatic:
0.01 g/L (ppt) from
1 µS/cm from 0 to 9999 µS/cm;
10.00 to 99.99 g/L (ppt);
0.01 mS/cm from 10.00 to 99.99 mS/cm;
0.1 g/L (ppt) from 100.0 to
0.1 mS/cm from 100.0 to 400.0 mS/cm;
400.0 g/L (ppt);
automatic mS/cm:
autorange g/L (ppt) scales:
0.001 mS/cm from 0.000 to 9.999 mS/cm;
0.001 g/L (ppt) from
0.01 mS/cm from 10.00 to 99.99 mS/cm;
0.000 to 9.999 g/L (ppt);
0.1 mS/cm from 100.0 to 400.0 mS/cm
0.01 g/L (ppt) from
10.00 to 99.99 g/L (ppt);
0.1 g/L (ppt) from
100.0 to 400.0 g/L (ppt)
Accuracy
±1% of reading or ±1 µS/cm,
whichever is greater
Turbidity
Resistivity
0.6 to
200 ppm
0.62 to 200 ppm
(as N)
0.01 ppm to 1 ppm; 0.1
ppm to 200 ppm
0.01 ppm to 1 ppm; 0.1
ppm to 200 ppm
Salinity
0.00 to
70.00 PSU
0 to 50.0 σ , σ , σ
dependent on
resistivity setting
0.01 PSU
0.1 σ , σ , σ
±1% of reading or ±1 mg/L,
whichever is greater
Dissolved Oxygen
Seawater σ
0 to 999999 Ω•cm;
0 to 1000.0 kΩ•cm;
0 to 1.0000 MΩ•cm
t
t
0
0
15
15
±1 σ , σ , σ
t
Atm. Pressure
0
15
Temperature
Range
0.0 to 99.9 FNU;
100 to 1000 FNU
0.0 to 500.0%;
0.00 to 50.00 ppm
450 to 850 mm Hg; 17.72 to 33.46 in Hg;
600.0 to 1133.2 mbar; 8.702 to 16.436 psi;
0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
-5.00 to 55.00°C;
23.00 to 131.00°F;
268.15 to 328.15K
Resolution
0.1 FNU from 0.0 to 99.9 FNU;
1 FNU from 100 to 1000 FNU
0.1%; 0.01 ppm
0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi;
0.0001 atm; 0.01 kPa
0.01°C; 0.01°F; 0.01K
±0.3 FNU or ±2% of reading,
whichever is greater
0.0 to 300.0%: ±1.5% of reading or
±1.0% whichever is greater; 300.0 to
500.0%: ±3% of reading; 0.00 to
±3 mm Hg within ±15°C from the temperature
30.00 ppm: ±1.5% of reading or 0.10 ppm, during calibration
whichever is greater; 30.00 ppm
to 50.00 ppm: ±3% of reading
Accuracy
±0.15°C; ±0.27°F; ±0.15K
Sensors for all meter and probe configurations are sold
separately. Choose your configuration below:
Meter only, carton box packaging
HI 9829-01
Meter only, charging adapter and
instruction manual, 115VAC
HI 9829-02
Same as HI 9829-01, for 230VAC
HI 98290-01
Meter only with GPS, charging adapter and
instruction manual, 115VAC
HI 98290-02
Same as HI 98290-01, for 230VAC
Probe only, no sensors,
carton box packaging
HI 7609829/4
Probe for pH/pH+ORP/ISE, DO, EC,
HI 7609829/10 temperature with HI 7698295 short
protective shield and 10 m (33’) cable
HI 7619829/4
Probe for pH/pH+ORP/ISE, DO,
EC+turbidity, temperature, with
HI 7698296 long protective shield
and 4 m (13.1’) cable
HI 7619829/10
Probe for pH/pH+ORP/ISE, DO,
EC+turbidity, temperature, with
HI 7698296 long protective shield
and 10 m (33’) cable
HI 7629829/4
Logging probe for pH/pH+ORP/
ISE, DO, EC, temperature with
HI 7698295 short protective shield
and 4 m (13.1’) cable
HI 7629829/10
Logging probe for pH/pH+ORP/ISE,
DO, EC, temperature with HI 7698295
short protective shield and 10 m
(33’) cable
HI 7639829/4
Logging probe for pH/pH+ORP/ISE,
DO, EC+turbidity, temperature, with
HI 7698296 long protective shield,
and 4 m (13.1’) cable
Meter, logging probe and carrying
case, no sensors
HI 98291-01
HI 9829 and HI 7629829/4 logging
probe for pH/pH+ORP/ISE, DO, EC,
temperature, with 4 m (13.1’) cable,
probe maintenance kit, charging
adapter, instruction manual and
hard carrying case, 115VAC
HI 98291-02
Same as HI 98291-01, for 230VAC
HI 98292-01
HI 9829 and HI 7639829/4 logging
probe for pH/pH+ORP/ISE, DO,
EC+turbidity, temperature, with 4 m
(13.1’) cable, probe maintenance kit,
charging adapter, instruction manual
and hard carrying case, 115VAC
Probe for pH/pH+ORP/ISE, DO, EC,
temperature with HI 7698295 short
protective shield and 4 m (13.1’) cable
Turbidity Calibration Solutions
HI 9829-16
0 FNU calibration solution, 230 mL
HI 9829-17
20 FNU calibration solution, 230 mL
HI 9829-18
200 FNU calibration solution, 230 mL
ISE Standards
Kit containing 10 sachets each of 10
HI 9829-10/11 ppm and 100 ppm standard for HI
7609829-10 ammonium ISE
10 ppm standard sachet for HI
7609829-10 ammonium ISE, 25 mL (25)
100 ppm standard sachet for HI
HI 9829-11
7609829-10 ammonium ISE, 25 mL (25)
Kit containing 10 sachets each of
HI 9829-12/13 10 ppm and 100 ppm standard for
HI 7609829-11 chloride ISE
10 ppm standard sachet for
HI 9829-12
HI 7609829-11 chloride ISE, 25 mL (25)
100 ppm standard sachet for HI
HI 9829-13
7609829-11 chloride ISE, 25 mL (25)
Kit containing 10 sachets each of
HI 9829-14/15 10 ppm and 100 ppm standard for
HI 7609829-12 nitrate ISE
10 ppm standard sachet for
HI 9829-14
HI 7609829-12 nitrate ISE, 25 mL (25)
100 ppm standard sachet for
HI 9829-15
HI 7609829-12 nitrate ISE, 25 mL (25)
HI 9829-10
HI 98292-02
Same as HI 98292-01, for 230VAC
HI 98293-01
HI 9829 and HI 7629829/10 logging
probe for pH/pH+ORP/ISE, DO,
EC, temperature, with 10 m (33’)
cable, probe maintenance kit, charging
adapter, instruction manual and hard
carrying case, 115VAC
HI 98293-02
Same as HI 98293-01, for 230VAC
HI 7609829-0
pH
pH/ORP Cleaning and Storage Solutions
HI 7609829-1
pH/ORP
HI 70300L
pH/ORP electrode storage sol., 500 mL
HI 7609829-2
Dissolved oxygen
HI 7061L
pH/ORP electrode cleaning sol., 500 mL
HI 98294-01
HI 9829 and HI 7639829/10 logging
probe for pH/pH+ORP/ISE, DO,
EC+turbidity, temperature, with 10
m (33’) cable, probe maintenance kit,
charging adapter, instruction manual
and hard carrying case, 115VAC
HI 7609829-3
EC
HI 7609829-4
EC/Turbidity
HI 98294-02
Same as HI 98294-01, for 230VAC
HI 7609829-11 Chloride ISE
HI 7609829-12 Nitrate ISE
HI 98295-01
HI 98290 with GPS and HI 7629829/4
logging probe for pH/pH+ORP/ISE,
DO, EC, temperature, with 4 m (13.1’
cable, probe maintenance kit, charging
adapter, instruction manual and hard
carrying case, 115VAC
Logging probe for pH/pH+ORP/ISE,
DO, EC+turbidity, temperature, with
HI 7639829/10
HI 7698296 long protective shield,
and 10 m (33’) cable
Sensors with O-ring
HI 7609829-10 Ammonium ISE
Quick Calibration Solutions
Short flow cell
Long, quick release flow cell
HI 7698295
Short protective shield
HI 7698296
Long protective shield
HI 98296-01
HI 7010L
pH 10.01 buffer solution, 500 mL
Hanna Instruments Inc.
584 Park East Drive, Woonsocket, RI 02895
401-765-0045
www.hannainst.com
Short calibration beaker
HI 7698297
pH 7.01 buffer solution, 500 mL
Same as HI 98298-01, for 230VAC
Cigarette lighter cable
HI 7698290
Long calibration beaker
HI 7007L
HI 98298-02
HI 710046
HI 7698294
pH 4.01 buffer solution, 500 mL
HI 98298-01
USB cable, PC to meter
HI 76982910 USB cable, PC to probe
Quick calibration solution, 1 gal.
HI 7004L
HI 98290 with GPS and HI 7639829/10
logging probe for pH/pH+ORP/ISE, DO,
EC+turbidity, temperature, with 10
m (33’) cable, probe maintenance kit,
charging adapter, instruction manual
and hard carrying case, 115VAC
PC application software
HI 7698291
HI 9828-27
HI 98290 with GPS and HI 7639829/4
logging probe for pH/pH+ORP/ISE,
DO, EC+turbidity, temperature, with 4
m (13.1’) cable, probe maintenance kit,
charging adapter, instruction manual
and hard carrying case, 115VAC
HI 98297-01
HI 929829
HI 7698293
pH Calibration Solutions
HI 98290 with GPS and HI 7629829/10
logging probe for pH/pH+ORP/ISE,
DO, EC, temperature, with 10 m (33’)
cable, probe maintenance kit, charging
adapter, instruction manual and hard
carrying case, 115VAC
Accessories
Quick calibration solution, 500 mL
Same as HI 98295-01, for 230VAC
Same as HI 98296-01, for 230VAC
HI 7698292
Probe maintenance kit consisting of
HI 7042S (electrolyte solution for DO
sensor), O-rings for DO sensor (5), small
brush, O-rings for probe (5), and syringe
with grease to lubricate the O-rings.
HI 9828-25
HI 98295-02
HI 98296-02
Probe Maintenance Kit
ORP Calibration Solutions
HI 7021L
ORP test solution @240 mV, 500 mL
HI 7022L
ORP test solution @470 mV, 500 mL
HI 920005
iButton® with holder (5 pcs)
HI 710140
Hard carrying case
HI 710045
Power supply cable
Conductivity Calibration Solutions
HI 7030L
12880 µS/cm cal. sol., 500 mL
HI 7031L
1413 µS/cm cal. sol., 500 mL
HI 7033L
84 µS/cm cal. sol., 500 mL
HI 7034L
80000 µS/cm cal. sol., 500 mL
HI 7035L
111800 µS/cm cal. sol., 500 mL
HI 7039L
5000 µS/cm cal. sol., 500 mL
Dissolved Oxygen Solutions
HI 7040L
Zero oxygen solution, 500 mL
HI 7042S
Electrolyte solution, 30 mL
P/L HI9829 1.0 1/12 PRINTED IN THE USA
Ordering Information